Loading...
HomeMy WebLinkAboutLS101.0 Life Safety PlansR R RR MWMW FITNESS CENTER WOMEN'SMEN'S DOCK EXISTING FURNITURE - SPIRITUAL LIBRARY EXISTING STAINED GLASS WINDOWS TO BE REUSED EXISTING DOORS WITH STAINED GLASS LITES TO BE REUSED P W R B R EA K 22Y 22Y F67/48G F67/24N F67/48G F67/24N F67/48G F67/24N F67/48G F67/24N A4860 A4860A4860A4860A4860 A486016'-8"9'-2"CORE DRILL CORE DRILL CORE DRILL CORE DRILLCORE DRILL CORE DRILL CORE DRILL CORE DRILL 14'-0"17'-2" 12'-3"17'-7" 17'-7"1'-8"CORE DRILL CORE DRILL CORE DRILL CORE DRILL CORE DRILL CORE DRILL CORE DRILL CORE DRILL CORE DRILL CORE DRILL CORE DRILL 17'-4" 17'-5" 17'-11" 17'-8" 17'-9" 17'-8" 17'-9"7'-4"5'-8"11'-3"21'-4"12'-6"9'-11"5'-10 3_4"5'-5"6'-8" 6'-6" 5'-5"3'-0"5'-0" CORE DRILL CORE DRILL 14'-0"BB BC ICICIAAA BB BC ICICIAAA BB BB CC CC CC CC BB BB CC CC CC CC BB BB BB BB BB BB CC CC CC CC CCCC BB BB BB BB CC CC CC CC CC C C A AA ABB BB BB BB CC CC CC CC A AA ABB BB BB BB CC CC CC CC A AA ABB BB BB BB CC CC CC CC A AA ABB BB BB BB CC CC CC CC 06A AA AA AA ABB BB BB BB CC CC CC CC 06A AA AA AA ABB BB BB BB CC CC CC CC C CCC AA B BBB B GA06 GA06 BB BB BB BB CC CC CC CC BB BB BB BB CC CC CC CC 12C 12C 06EAAAA AA AA AAAA AA AA AA AA AA AA A A A AA A A AA A A AA A A AA A A AA A A A 1E 1E GA06GA06AA A BCDAA A BCDAA A BCDA A A B C D A A A B C D A A A B C D A A A BCDA A ABCD A A ABCD AA A BC D AA A BC D AA A BC D 06EAA AA AA AA AA AA A AA AA AA AA AA A1E 1E AA A BCDAA A BCDAA A BCDA A A BCDA A ABCD A A ABCD A AA A AA A AAAAAAAAAAAAAAAAAAA A A A A A AA AA AA AA AA R R R EXIT EXIT EXIT36"EXIT161' - 0" 184' - 6" 1 22 1 2 3 3 CALC. CAPACITY ANTICIPATED 240 364 CALC. CAPACITY ANTICIPATED 480 364 EXIT (2) EXITS AT 72" EA. CALC. CAPACITY ANTICIPATED 400 364 (3) EXITS AT 72" EA. EXIT CALC. CAPACITY ANTICIPATED 480 364 FEC 60"EXISTING FEC EXISTING FEC EXISTING FEC 145' - 6" 206' - 6" 143' - 6" 158' - 0" 121' - 0" 7 SYMBOL/LINETYPE DESCRIPTION 1 HR FIRE BARRIER 2 HR SMOKE/FIRE BARRIER SMOKE RESISTANT CORRIDOR NOT IN PROJECT SCOPE LIFE SAFETY PLAN LEGEND NOTE: Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or stenciling as follows: 1. Locate above suspended lay-in panel ceilings and in accessible attic spaces. 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in height with a minimum 3/8 inch stroke in a contrasting color incorporating the wording: "FIRE WALL or FIRE BARRIER – PROTECT ALL OPENINGS". PROJECT LIMITS CODE SUMMARY Indiana Building Codes: 2014 Indiana Building Code (IBC)* General Administrative Rules, 2nd Edition (GAR) 2014 Indiana Fire Code 2014 Indiana Mechanical Code 2014 Indiana Plumbing Code 2009 Indiana Electrical Code 2010 Indiana Energy Conservation Code 2012 IBC Chapter 11 w/ Amendments & 2009 ANSI A117.1 (Handicapped Accessibility Code) *Code references are from the 2014 IBC unless otherwise noted. Applicable Codes: 117,470 SQ. FT.Construction Area: B - Business Office [Sec. 304.1, IBC] A-3 - Assembly (Accessory Use) [Sec. 303.4, IBC] Occupancy Classification: The project involves a renovation of an existing 5-story building. Renovation will occur on the first, second, fourth and portion of the fifth floors. No change in occupancy or construction type. Project Description: Existing Sprinkler System: Existing Smoke Detector System: Existing Fire Alarm System: Construction Type: 192,327 SQ. FT. (EXISTING)Building Area: Yes, Fully Sprinklered Automatic Yes Yes Type II-B Existing Common Path of Travel: 75 ft A Occupancy [1014.3, IBC] 100 ft B Occupancy Exit Access Travel: 250 ft A Occupancy [1016.2, IBC] 300 ft B Occupancy Travel Distance: EXIT EXIT EXIT 138' - 0" 148' - 0" 147' - 6" 2 2 2 3 3 FEC FEC 3 3 EXISTING FEC EXISTING FEC FEC EXISTING FEC FEC FIRST FLOOR 'B' Occupancy II-B Construction - Existing Area: Actual Area = 36,777 sq. ft. Scope Area = 25,462 sq. ft. SECOND FLOOR 'B' Occupancy II-B Construction - Existing Area: Actual Area = 38,834 sq. ft. Scope Area = 36,779 sq. ft. 12 3 4 5 A B C D E 6 TRUE NORTH arcDESIGN PROJECT NUMBER: DATE: DRAWING TITLE: DRAWING NUMBER: REVISIONS: DRAWN BY: CLIENT PROJECT NUMBER: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN.C:\Users\kfunston\Documents\Revit 2017 Local\250 W 96th_firestone bldg_CENTRAL_kfunston.rvt4/5/2018 3:59:17 PM ASCENSION | ST. VINCENTG001 LIFE SAFETY PLANS 15140A 03.06.2018 100% CONSTRUCTION DOCUMENTS30029-INDIANAPOLIS - ST. VINCENT HEALTHADMINISTRATION OFFICE250 W. 96TH STREET - PARKWOOD BUILDINGINDIANAPOLIS, IN 46260AED ININD30029 1/16" = 1'-0" LIFE SAFETY PLAN - FIRST FLOOR1A 1/16" = 1'-0" LIFE SAFETY PLAN - SECOND FLOOR2A FLOOR PLAN NOTES - LIFE SAFETY 1 EXISTING 2-HR RATED EXIT CORRIDOR. 2 EXISTING 2-HR RATED STAIR ENCLOSURE. NO WORK THIS AREA. 3 EXISTING 2-HR RATED SHAFT ENCLOSURE. NO WORK THIS AREA. 7 03.30.2018 PR04- TENANT SHARED SPACE SCOPE 05/01/18 Nick Mishler