Loading...
HomeMy WebLinkAboutA113-THIRD-FLOOR-REFLECTED-CEILING-PLAN-Rev.2M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M D D D D M M D D OFFICE M 331 OFFICE 330 OFFICE 329 INTERVIEW 328 MEETING 327 CONFERENCE 325 OFFICE 322 OFFICE 321 AUDIT 320 MEETING 319 PATIO 318 OFFICE 332 IT OFFICE 333 OFFICE 334 OPEN OFFICE 335 COFFEE HUB 341 WAR ROOM 340 MARKETING 339 IT 338 STAIR 1 S1 OPEN OFFICE 342 OFFICE 343 OFFICE 344 OFFICE 345 OFFICE 346 OFFICE 347 OFFICE 348 CONFERENCE 352 TRAINING 353a TRAINING 353b TABLES 354 SOCIAL HUB 356 LOUNGE 315 STAIR 2 S2 LOUNGE 314 OPEN OFFICE 324 WAR ROOM GATHER 323 326 MEN 304 WOMEN 303 JAN 308 HALLWAY 309 LOBBY 302 CORRIDOR 355 GATHER 317 LOCKER 4 313 LOCKER 3 312 LOCKER 2 311 LOCKER 1 310 RECEPTION 301 OPEN OFFICE 336 IT 306 ELEC 307 SERVICE 305 BREAKOUT 351 STAGING 337 OPEN OFFICE 349 1 2 3 4 5 6 7 8 9 A B C D E F C.5 SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CLIENT ARCHITECT 17105 NOVEMBER 15, 2017 CONSTRUCTION ISSUE MERCHANTS CORPORATE CENTER CARMEL, IN D I L L O N CONSTRUCTION G R O U P CONSTRUCTION MANAGER # REVISION DATE THIRD FLOOR REFLECTED CEILING PLAN EXP. PAINTED 9'-0" 8'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" EXP. PAINTED EXP. PAINTED A113 9'-4" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 8'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-4" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" EXP. PAINTED 9'-0" 9'-0" 9'-4" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" SCALE: 01 REFLECTED CEILING PLAN THIRD FLOOR 1/8" = 1'-0" 9'-4" 9'-4" 9'-0" 8'-6" 8'-6" 9'-4" 9'-4" 9'-4" 9'-4" 9'-4" 8'-6" 9'-0" 9'-0" 9'-0" 9'-0" 8'-6" 9'-0" 9'-0" 9'-0" EXP. PAINTED 8'-0" CEILING LEGEND: 1.ARE LIGHTS, DIFFUSERS, AND SPRINKLER HEADS 2.BE ALL SUSPENDED ACOUSTICAL CEILINGS ARE TO AT-1 UNLESS NOTED OTHERWISE. DRAWINGS FOR ADDITIONAL INFORMATION. AT-1 LIGHT FIXTURE - SEE ELECTRICAL SUSPENDED 5/8" GYPSUM BOARD CEILING 24" x 24" DIFFUSER - SEE MECHANICAL RETURN OR EXHAUST - SEE MECHANICAL GENERAL CEILING NOTES: SHOWN FOR LOCATION ONLY. SEE ENGINEERING CEILING PLAN NOTES 1 NOT USED. NOT USED. 1/2" ALUMINUM REVEAL CHANNEL SCREED. 1/2" FORMED EIFS REVEAL. PARTIAL HEIGHT WALL BELOW. PROVIDE 6" CROWN MOLDING. RECESSED COVE LIGHTING. 2 3 24" X 24" X 1" ARMSTRONG OPTIMA CEILING TILES WITH TEGULAR EDGE. W-2 96" X 5-1/4" ARMSTRONG WOODWORKS LINEAR FINISH: MAPLE (NMP) SUSPENDED EIFS CEILING W-1 ARMSTRONG WOODWORKS CONCEALED CEILING SYSTEM WITH 24" X 72" X 3/4" PANELS. FINISH: MAPLE (NMP), W1 UNPERFORATED. 4 5 6 7 W-3 24" X 24" OPEN GRID SYSTEM (PAINTED BLACK) TILES AS SHOWN. FINISH: MAPLE (NMP), W2 PERFORATED. WITH ARMSTRONG WOODWORKS TEGULAR CEILING G-1 48" X 48" OPEN GRID W/ TEES AND TILES STACKED ON FLOOR. 2ND FLOOR ONLY. 48"x 6" LINEAR DIFFUSER - SEE MECHANICAL AT-1 W1 W1 W1 W1 4 TYP. 3 TYP. 3 TYP. W1 7 7 7 7 8'-0" 8'-0" 9'-0" W3 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 10'-0" 10'-0" 10'-0" 10'-0" 30'-0" W3 EXP. PAINTED 8'-0" EXP. PAINTED B/O BULKHEAD: 8'-6" T/O BULKHEAD: 10'-6" B/O BULKHEAD: 8'-6" T/O BULKHEAD: 10'-6" 8'-8" 8'-8" W3 W3 5 A120 1 3 6 A120 7 A120 3 9'-0" 4 A120 8 A120 8 A120 12 A120 12 A120 SIM. 5 A120 1 1 13 A120 05/01/18 Nick Mishler