HomeMy WebLinkAboutA114-FOURTH-FLOOR-REFLECTED-CEILING-PLAN-Rev.2M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M
M
M
M
M
D
D D
D
3
D
M
M
M
M
OFFICE
441
OFFICE
440
OFFICE
439
OFFICE
438
MEETING
434
OFFICE
427
OFFICE
426
PATIO
422
OFFICE
442
OFFICE
443
OFFICE
444
OPEN OFFICE
448
OFFICE
445
OFFICE
452
STAIR 1
S1
OPEN OFFICE
457
OFFICE
462
OFFICE
464
OFFICE
465
PRINTING
460
OFFICE
461
MEETING
463
CONFERENCE
417
LOUNGE
415
STAIR 2
S2
OPEN OFFICE
431
WAR ROOM
432
MEN
404
WOMEN
403
JAN
408
HALLWAY
409
LOBBY
402
OPEN OFFICE
466
OFFICE
421
REST.
413
MOTHER'S
ROOM
411
COFFEE HUB
410
LOBBY
401
IT
406
ELEC
407
SERVICE
405
OFFICE
458
OFFICE
455
OFFICE
430
OFFICE
429
REST.
414
OUTDOOR
MEETING 424
425
OFFICE
428
OFFICE
459
OFFICE
420
OFFICE
419
OFFICE
418
OFFICE
446
OFFICE
453
OFFICE
450
OFFICE
451
OFFICE
456
OPEN OFFICE
416
CORRIDOR
423
OFFICE
412
WAR ROOM
437
PRIVATE
435
PRIVATE
433
PHONE
460a
PHONE
460b
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
C.5
SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CLIENT ARCHITECT
17105
NOVEMBER 15, 2017
CONSTRUCTION ISSUE
MERCHANTS
CORPORATE
CENTER
CARMEL, IN
D I L L O N
CONSTRUCTION
G R O U P
CONSTRUCTION MANAGER
# REVISION DATE
FOURTH FLOOR
REFLECTED
CEILING PLAN
A114
9'-0"
9'-0" 9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0" 9'-0" 9'-0"
9'-0"
9'-0"
9'-0" 9'-0" 9'-0"
9'-0"
9'-8"
9'-0" 9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-4"
9'-0"
9'-0" 9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
EXP.
PAINTED
EXP.
PAINTED
EXP.
PAINTED
9'-0"
9'-0"
VARIES
9'-4"
EXP.
PAINTED
9'-0"
9'-0"
9'-4"
9'-0"
SCALE:
01 REFLECTED CEILING PLAN
FOURTH FLOOR
1/8" = 1'-0"
9'-0" 9'-0"
9'-4" 9'-4" 9'-4" 9'-4"
9'-0"
CEILING LEGEND:
1.ARE LIGHTS, DIFFUSERS, AND SPRINKLER HEADS
2.BE ALL SUSPENDED ACOUSTICAL CEILINGS ARE TO
AT-1 UNLESS NOTED OTHERWISE.
DRAWINGS FOR ADDITIONAL INFORMATION.
AT-1
LIGHT FIXTURE - SEE ELECTRICAL
SUSPENDED 5/8" GYPSUM BOARD CEILING
24" x 24" DIFFUSER - SEE MECHANICAL
RETURN OR EXHAUST - SEE MECHANICAL
GENERAL
CEILING NOTES:
SHOWN FOR LOCATION ONLY. SEE ENGINEERING
CEILING PLAN NOTES
1 NOT USED.
NOT USED.
1/2" ALUMINUM REVEAL CHANNEL SCREED.
1/2" FORMED EIFS REVEAL.
PARTIAL HEIGHT WALL BELOW.
PROVIDE 6" CROWN MOLDING.
RECESSED COVE LIGHTING.
2
3
24" X 24" X 1" ARMSTRONG OPTIMA CEILING TILES
WITH TEGULAR EDGE.
W-2
96" X 5-1/4" ARMSTRONG WOODWORKS LINEAR
FINISH: MAPLE (NMP)
SUSPENDED EIFS CEILING
W-1
ARMSTRONG WOODWORKS CONCEALED
CEILING SYSTEM WITH 24" X 72" X 3/4" PANELS.
FINISH: MAPLE (NMP), W1 UNPERFORATED.
4
5
6
7
W-3
24" X 24" OPEN GRID SYSTEM (PAINTED BLACK)
TILES AS SHOWN. FINISH: MAPLE (NMP), W2 PERFORATED.
WITH ARMSTRONG WOODWORKS TEGULAR CEILING
G-1
48" X 48" OPEN GRID W/ TEES AND TILES STACKED
ON FLOOR. 2ND FLOOR ONLY.
48"x 6" LINEAR DIFFUSER - SEE MECHANICAL
AT-1
AT-1
AT-1
W-1
W-2
6
4
TYP.
3 TYP.
7
7
30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"
30'-0" 10'-0" 10'-0" 10'-0" 10'-0" 30'-0"
5
A120
9'-0"
6
A120
9
A120
1
4
A120
05/01/18
Nick Mishler