Loading...
HomeMy WebLinkAboutA114-FOURTH-FLOOR-REFLECTED-CEILING-PLAN-Rev.2M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M D D D D 3 D M M M M OFFICE 441 OFFICE 440 OFFICE 439 OFFICE 438 MEETING 434 OFFICE 427 OFFICE 426 PATIO 422 OFFICE 442 OFFICE 443 OFFICE 444 OPEN OFFICE 448 OFFICE 445 OFFICE 452 STAIR 1 S1 OPEN OFFICE 457 OFFICE 462 OFFICE 464 OFFICE 465 PRINTING 460 OFFICE 461 MEETING 463 CONFERENCE 417 LOUNGE 415 STAIR 2 S2 OPEN OFFICE 431 WAR ROOM 432 MEN 404 WOMEN 403 JAN 408 HALLWAY 409 LOBBY 402 OPEN OFFICE 466 OFFICE 421 REST. 413 MOTHER'S ROOM 411 COFFEE HUB 410 LOBBY 401 IT 406 ELEC 407 SERVICE 405 OFFICE 458 OFFICE 455 OFFICE 430 OFFICE 429 REST. 414 OUTDOOR MEETING 424 425 OFFICE 428 OFFICE 459 OFFICE 420 OFFICE 419 OFFICE 418 OFFICE 446 OFFICE 453 OFFICE 450 OFFICE 451 OFFICE 456 OPEN OFFICE 416 CORRIDOR 423 OFFICE 412 WAR ROOM 437 PRIVATE 435 PRIVATE 433 PHONE 460a PHONE 460b 1 2 3 4 5 6 7 8 9 A B C D E F C.5 SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CLIENT ARCHITECT 17105 NOVEMBER 15, 2017 CONSTRUCTION ISSUE MERCHANTS CORPORATE CENTER CARMEL, IN D I L L O N CONSTRUCTION G R O U P CONSTRUCTION MANAGER # REVISION DATE FOURTH FLOOR REFLECTED CEILING PLAN A114 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-8" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-4" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" EXP. PAINTED EXP. PAINTED EXP. PAINTED 9'-0" 9'-0" VARIES 9'-4" EXP. PAINTED 9'-0" 9'-0" 9'-4" 9'-0" SCALE: 01 REFLECTED CEILING PLAN FOURTH FLOOR 1/8" = 1'-0" 9'-0" 9'-0" 9'-4" 9'-4" 9'-4" 9'-4" 9'-0" CEILING LEGEND: 1.ARE LIGHTS, DIFFUSERS, AND SPRINKLER HEADS 2.BE ALL SUSPENDED ACOUSTICAL CEILINGS ARE TO AT-1 UNLESS NOTED OTHERWISE. DRAWINGS FOR ADDITIONAL INFORMATION. AT-1 LIGHT FIXTURE - SEE ELECTRICAL SUSPENDED 5/8" GYPSUM BOARD CEILING 24" x 24" DIFFUSER - SEE MECHANICAL RETURN OR EXHAUST - SEE MECHANICAL GENERAL CEILING NOTES: SHOWN FOR LOCATION ONLY. SEE ENGINEERING CEILING PLAN NOTES 1 NOT USED. NOT USED. 1/2" ALUMINUM REVEAL CHANNEL SCREED. 1/2" FORMED EIFS REVEAL. PARTIAL HEIGHT WALL BELOW. PROVIDE 6" CROWN MOLDING. RECESSED COVE LIGHTING. 2 3 24" X 24" X 1" ARMSTRONG OPTIMA CEILING TILES WITH TEGULAR EDGE. W-2 96" X 5-1/4" ARMSTRONG WOODWORKS LINEAR FINISH: MAPLE (NMP) SUSPENDED EIFS CEILING W-1 ARMSTRONG WOODWORKS CONCEALED CEILING SYSTEM WITH 24" X 72" X 3/4" PANELS. FINISH: MAPLE (NMP), W1 UNPERFORATED. 4 5 6 7 W-3 24" X 24" OPEN GRID SYSTEM (PAINTED BLACK) TILES AS SHOWN. FINISH: MAPLE (NMP), W2 PERFORATED. WITH ARMSTRONG WOODWORKS TEGULAR CEILING G-1 48" X 48" OPEN GRID W/ TEES AND TILES STACKED ON FLOOR. 2ND FLOOR ONLY. 48"x 6" LINEAR DIFFUSER - SEE MECHANICAL AT-1 AT-1 AT-1 W-1 W-2 6 4 TYP. 3 TYP. 7 7 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 10'-0" 10'-0" 10'-0" 10'-0" 30'-0" 5 A120 9'-0" 6 A120 9 A120 1 4 A120 05/01/18 Nick Mishler