HomeMy WebLinkAboutA115-FIFTH-FLOOR-REFLECTED-CEILING-PLAN-Rev.2M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M
M M
M
M M
M
M M
M
M
M
M
M
M
M
M
M
M
M M
M
M
M
M
M
M
M
D
D
M
OFFICE
542
OFFICE
541
OFFICE
540
OFFICE
539
MEETING
532
OFFICE
528
OFFICE
527
PATIO
524
OFFICE
543
OFFICE
544
OFFICE
545 OPEN OFFICE
546
COFFEE HUB
548
OFFICE
551
STAIR 1
S1
OPEN OFFICE
555
BOARD ROOM
519
LOUNGE
520
STAIR 2
S2
OPEN OFFICE
524
WAR ROOM
533
MEN
504
WOMEN
503
JAN
508
HALLWAY
509
LOBBY
502
CORRIDOR
515
REST.
522
MEETING
510
LOBBY
501
IT
506
ELEC
507
SERVICE
505
OFFICE
557
OFFICE
547
OFFICE
531
OFFICE
530
REST.
521
OUTDOOR
525
FILE STORAGE
526
OFFICE
529
OFFICE
558
OFFICE
552
OFFICE
553
OFFICE
550
OFFICE
554
CORRIDOR
523
GATHER
513
WAR ROOM
537
PRIVATE
536
PRIVATE
535
PHONE
555a
PHONE
555b
PRINT
538
MEETING
561
OFFICE
559
OFFICE
560
PHONE
511
MOTHER'S
ROOM
512
OFFICE
516
OFFICE
517
OFFICE
518
PHONE
514a
PHONE
514b
OPEN OFFICE
514
M
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
C.5
SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CLIENT ARCHITECT
17105
NOVEMBER 15, 2017
CONSTRUCTION ISSUE
MERCHANTS
CORPORATE
CENTER
CARMEL, IN
D I L L O N
CONSTRUCTION
G R O U P
CONSTRUCTION MANAGER
# REVISION DATE
FIFTH FLOOR
REFLECTED
CEILING PLAN
A115
9'-0"
9'-0"
9'-0"
EXP.
PAINTED
EXP.
PAINTED
EXP.
PAINTED
EXP.
PAINTED
9'-0"
9'-0"
9'-0" 9'-0"
9'-0" 9'-0" 9'-0" 9'-0"
9'-0"
9'-0" 9'-0" 9'-0"
9'-8"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0" 9'-0" 9'-0"
VARIES
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0" 9'-0" 9'-0" 9'-0"
8'-8"
9'-0" 9'-0"
9'-0"
9'-0"
9'-4"
9'-0"
SCALE:
01 REFLECTED CEILING PLAN
FIFTH FLOOR
1/8" = 1'-0"
9'-0"
9'-0" 9'-0"
9'-4"
9'-0" 9'-0" 9'-0" 9'-0"
9'-4" 9'-0"
9'-4"
CEILING LEGEND:
1.ARE LIGHTS, DIFFUSERS, AND SPRINKLER HEADS
2.BE ALL SUSPENDED ACOUSTICAL CEILINGS ARE TO
AT-1 UNLESS NOTED OTHERWISE.
DRAWINGS FOR ADDITIONAL INFORMATION.
AT-1
LIGHT FIXTURE - SEE ELECTRICAL
SUSPENDED 5/8" GYPSUM BOARD CEILING
24" x 24" DIFFUSER - SEE MECHANICAL
RETURN OR EXHAUST - SEE MECHANICAL
GENERAL
CEILING NOTES:
SHOWN FOR LOCATION ONLY. SEE ENGINEERING
CEILING PLAN NOTES
1 NOT USED.
NOT USED.
1/2" ALUMINUM REVEAL CHANNEL SCREED.
1/2" FORMED EIFS REVEAL.
PARTIAL HEIGHT WALL BELOW.
PROVIDE 6" CROWN MOLDING.
RECESSED COVE LIGHTING.
2
3
24" X 24" X 1" ARMSTRONG OPTIMA CEILING TILES
WITH TEGULAR EDGE.
W-2
96" X 5-1/4" ARMSTRONG WOODWORKS LINEAR
FINISH: MAPLE (NMP)
SUSPENDED EIFS CEILING
W-1
ARMSTRONG WOODWORKS CONCEALED
CEILING SYSTEM WITH 24" X 72" X 3/4" PANELS.
FINISH: MAPLE (NMP), W1 UNPERFORATED.
4
5
6
7
W-3
24" X 24" OPEN GRID SYSTEM (PAINTED BLACK)
TILES AS SHOWN. FINISH: MAPLE (NMP), W2 PERFORATED.
WITH ARMSTRONG WOODWORKS TEGULAR CEILING
G-1
48" X 48" OPEN GRID W/ TEES AND TILES STACKED
ON FLOOR. 2ND FLOOR ONLY.
48"x 6" LINEAR DIFFUSER - SEE MECHANICAL
AT-1
W-1
W-1
5
4
3 TYP.
TYP.
3 TYP.
6
7
7
7
30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0"
30'-0" 10'-0" 10'-0" 10'-0" 10'-0" 30'-0"
1 CONST. ISSUE 2017-11-1
5
A120
9
AXXX
10
A120
4'-10"
4'-81
4"
3'-73
4"
2'-11
2"
2'-53
8"
2'-31
2"
4'-11
8"
05/01/18
Nick Mishler