Loading...
HomeMy WebLinkAbout04090153 Building PlansLUCRE FINANCIAL SERVICES AT CLAY TERRACE 14300 CLAY TERRACE BLVD, 2ND FLOOR, SUIT1 09 -08 - CARMEL, IN 46032 CONSTRUCTION RELEA PROJECT TEAM OWNER CLAY TERRACE PARTNERS, LLC 9777 COLLEGE AVENUE INDIANAPOLIS, IN 46280 317-575-3035 (F)317-564-3035 GENERAL CONTRACTOR LAUTH PROPERTY GROUP 9777 COLLEGE AVENUE INDIANAPOLIS, IN 46280 317-575-3035 (F)317-564-3035 ARCHITECT ROWLAND DESIGN INC. 701 EAST NEW YORK STREET INDIANAPOLIS, IN 46202 317-636-3980 (F)317-263-2073 PLUMBING DESIGN/BUILD EDWARDS MECHANICAL, INC. 6831 E. 32ND ST. INDIANAPOLIS, IN 46226 317-543-3460 (F)317-543-3476 HVAC DESIGN/BUILD ENTERPRISE ELECTRICAL & MECHANICAL CO. 6809 HILLSDALE INDIANAPOLIS, IN 46250 PHONE: 317-863-0007 FAX: 317-863-0021 ELECTRICAL DESIGN/BUILD BARTH ELECTRIC 1934 NORTH ILLINOIS STREET INDIANAPOLIS, IN 46202 317-924-6226 317-923-6938 CODE INFORMATION BUILDOUT SQUARE FOOTAGE: 2641 USABLE SQUARE FEET CONSTRUCTION TYPE: OCCUPANCY: a y� a Cod' APPLICABLE BUILDING CODES: 1998 IND (1997 UNIF 1998 INDIANA 1998 INDIA 1998 INDIA 1998 INIP ?'LDING CODE BUILDING CODE) PREVENTION CODE ELECTRIC CODE IECHANICAL CODE PLUMBING CODE INDEX OF DRAWINGS ARCHITECTURAL DRAWINGS A200 FLOOR PLAN A400 REFLECTED CEILING PLAN A700 FINISH PLAN AND SCHEDULE A810 ELECTRICAL & COMMUNICATIONS PLAN CLIENT LOGO AREA MAP RELEASED FOR COMIT C Subject to compliance with an P,O, ' of State and Loc OEPT 01= cOF ���.�E.�i,. , # -$-ff-FmAAP IOQblectto co„�tiarc„CQST E T OF r, and f .: SLI"aV no � CARMEL � ';I -Ar .r:o�``�t�ES -J CITY OF CARMEL/CLAY TOWNSHIP Dept. of Community Services -- Building & Code Enforcement One Civic Square P Floor; Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGRE ENI s the autho ' ed agent responsible for obtaining a permit or permits', I certify that t se plans re IDI, I, to those released fo construction by the Indiana Depart. of Fire & B ding ,Services. t so understand thats/�etermined that these plans are not identical, a TOP WORK O ER will I i4erve y uired under the Ordinances referenced below. Auth 'zed Signature Printed Name Re ired under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and ]Sec,:,,29.4.2 Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning O 3 .1 entitled "Violations and Penalties". S:Permi is /Forms/ AuthentStickerl 1-01 P /f s CODE INFORMATION BUILDOUT SQUARE FOOTAGE: 2641 USABLE SQUARE FEET CONSTRUCTION TYPE: OCCUPANCY: a y� a Cod' APPLICABLE BUILDING CODES: 1998 IND (1997 UNIF 1998 INDIANA 1998 INDIA 1998 INDIA 1998 INIP ?'LDING CODE BUILDING CODE) PREVENTION CODE ELECTRIC CODE IECHANICAL CODE PLUMBING CODE INDEX OF DRAWINGS ARCHITECTURAL DRAWINGS A200 FLOOR PLAN A400 REFLECTED CEILING PLAN A700 FINISH PLAN AND SCHEDULE A810 ELECTRICAL & COMMUNICATIONS PLAN CLIENT LOGO AREA MAP RELEASED FOR COMIT C Subject to compliance with an P,O, ' of State and Loc OEPT 01= cOF ���.�E.�i,. , # -$-ff-FmAAP IOQblectto co„�tiarc„CQST E T OF r, and f .: SLI"aV no � CARMEL � ';I -Ar .r:o�``�t�ES -J CITY OF CARMEL/CLAY TOWNSHIP Dept. of Community Services -- Building & Code Enforcement One Civic Square P Floor; Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGRE ENI s the autho ' ed agent responsible for obtaining a permit or permits', I certify that t se plans re IDI, I, to those released fo construction by the Indiana Depart. of Fire & B ding ,Services. t so understand thats/�etermined that these plans are not identical, a TOP WORK O ER will I i4erve y uired under the Ordinances referenced below. Auth 'zed Signature Printed Name Re ired under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and ]Sec,:,,29.4.2 Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning O 3 .1 entitled "Violations and Penalties". S:Permi is /Forms/ AuthentStickerl 1-01 P /f GENERAL NOTES: 1. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS, AND STANDARDS INCLUDING BUT NOT LIMITED TO THE INDIANA BUILDING CODE, THE INDIANA HANDICAPPED CODE, THE INDIANA PLUMBING, MECHANICAL, AND ELECTRICAL CODES, THE INDIANA FIRE CODE, THE AMERICANS WITH DISABILITIES ACT (ADA), AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITION. 2. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR TO START OF WORK REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER IMMEDIATELY. 3. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS REQUIRED FOR THE COMPLETION OF THE PROJECT. 4. ALL WORK 15 TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF THE OWNER'S FIXTURES, FURNISHINGS, AND EQUIPMENT. 5. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FINISHED FACE OF WALLS. 6. ALL DIMENSIONS REQUIRED ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER. DO NOT SCALE DIMENSIONS. -1. FINISHED DOOR OPENINGS IN ALL NEW PARTITIONS SHALL BE SET TO ALLOW FULL TRIM EXPOSURE (4' MIN.) FROM ADJACENT PERPENDICULAR PARTITION, UNLESS NOTED OTHERWISE. 8. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT. 9. ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED WITH THE ARCHITECT/DESIGNER AND LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION. 10. INSIDE CORNER DOOR RETURN, 4' TYPICAL FROM H.M. D24' -10Y4" 5'-0° FRAME (6' NET). VERIF'T ARCHITECTURAL FLOOR PLAN NOTES: APPLY THIS SHEET ONLY. G ALIGN WALL WITH EDGE OF WINDOW MULLION O CONTRACTOR TO PROVIDE GRAY BAR OR EQUAL TELEPHONE CABINET. CONTRACTOR TO VERIFY SIZE WITH LAUTH IT PRIOR TO PURCHASING UNIT. CABINET DIMENSIONS TO BE CONFIRMED PRIOR TO BUILDING ADJACENT WALL. 0 ALIGN WALL WITH EDGE OF COLUMN WRAP ® DEMOLITION PARTIAL FLOOR PLAN 1/4'= 1'4r DOOR SCHEDULE: OFFICE DOOR TO OFFICE 208: 3'0'x 5'0'X 1-3/4', PRE FINISHED, PRE MACHINED, SOLID CORE DOOR IN HOLLOW METAL KNOCKDOWN FRAME. HARDWARE: 2 PAIR BUTTS, MUTES, AND BEST 7KC LOCK SET. DOOR SPECIES, FINISH AND HARDWARE ARE TO MATCH BUILDING STANDARDS ALL OTHER OFFICE AND CONFERENCE ROOM DOORS: 3'0'x 8'0'X 1-3/4, PRE FINISHED, PRE MACHINED, SOLID CORE DOOR IN HOLLOW METAL KNOCKDOWN FRAME. HARDWARE: 2 PAIR BUTTS, MUTES, AND BEST 7KC PASSAGE SET. DOOR SPECIES, FINISH AND HARDWARE ARE TO MATCH BUILDING STANDARDS DOOR TO CORRIDOR FROM TENANT ENTRY: 3'0'x 5'0'X 1-3/4', PRE FINISHED, PRE MACHINED, SOLID CORE DOOR IN HOLLOW METAL BUILDING STANDARD FRAME WITH 18' WIDE SIDE LITE. SIDE LITE TO HAVE 2' HIGH MAIL SLOT IN GLASS, SET AT 24' AFF. HARDWARE: 2 PAIR BUTTS, MUTES, CLOSER AND LOCK SET TO MATCH BUILDING STANDARD. DOOR SPECIES, FINISH AND HARDWARE ARE TO MATCH EXISITNG. DEMOLITION NOTES: CONTRACTOR IS RESPONSIBLE FOR COMPLETE PATCH AND REPAIR OF ALL SURFACES DAMAGED DURING DEMOLITION AND/OR CONSTRUCTION. ALL DAMAGED SURFACES SHALL BE REPAIRED OR REPLACED USING MATERIALS WITH MINIMUM QUALITY EQUAL TO THAT OF ORIGINAL OR ADJACENT MATERIAL, WHICHEVER QUALITY 15 HIGHER ALL REPAIRED/REPLACED SURFACES ARE TO BE PREPARED TO RECEIVE FINISHES AS SCHEDULED WITHOUT VISIBLE SEAM OR SEPARATION 2. CONTRACTOR TO PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES. REFER TO FINISH SCHEDUI-E FOR ALL INTENDED FINISHES. 3. WHERE WALL AND FLOOR OUTLETS ARE TO BE REMOVED, ALL DEVICES AND WIRE ARE TO BE REMOVED BACK TO THEIR RESPECTIVE SOURCES. PATCH AND CAP ALL REMAINING OPENINGS AS REQUIRED TO PROVIDE A SMOOTH SURFACE FOR NcW FINISH WORK 4. ANY DOORS, FRAMES, TRIM, FIXTURES, AND OTHER ITEMS OF VALUE OR RE -USE POTENTIAL ARE TO BE SAVED AND RETURNED TO OWNER 5. REFER TO OTHER SHEETS FOR ADDITIONAL DEMOLITION INFORMATION. (o. SEE FNI5H PLANS FOR EXISTING CORRIDOR FINISHES FOR PATCHING. DEMOLITION PLAN NOTES: APPLY THIS SHEET ONLY. EXISTING WALL CONSTRUCTION TO BE REMOVED TO ALLOW -,]FOR NEW DOOR AND SIDE LITE. 2 ARCHITECTURAL FLOOR PLAN 1/4'= 1'-0' kk 4 ING LINE VINYL BASE WALL TYPE SCHEDULE EXISTING BUILDING WALL DEMISING WALL (IF NOT EXISTING) 3-5/8' 18 GA. METAL STUDS WITH 5/8' TYPE 'X' GYPSUM WALLBOARD TENANT SIDE. EXTEND TO DECK ABOVE. FILL WALL CAVITY WITH ACOUSTIC BATT INSULATION. 3-5/8' 25 GA. METAL STUDS WITH 5/8' TYPE 'X' GYPSUM WALLBOARD BOTH SIDES. EXTEND TO 4' ABOVE CEILING LINE. EXISTING EXTERIOR CONSTRUCTION TO BE COVERED WITH 2-1/2" 25 GA. METAL STUDS WITH 5/8' TYPE 'X' GYPSUM WALLBOARD ONE SIDE EXTEND TO 4' ABOVE CEILING LINE AS EXISTING CONDITIONS AND EXISTING FRAMING MAY REQUIRE. a�' 8Y' s ELEVATION 1/41= 1'-0' NORTW eLOCATION FLOOR PLAN ws r O >-1 FW— D cv X i m Y W C (_i Z m s � s W a z & v W a u c o L!a Z J` Q N FW— D cv �_°UA _ < O m Y W C (_i Z m C`7 Q z z F c Q z 0 LL NQ Fes` WQ &�Iq DQ �-J Cn_ W H 0 m DRAWING N0. A 2 TITLE: pum I f 0 CEILING PLAN NOTES: GYP BD PER STANDARD EXTERIOR BULKHEAD DETAILS 1. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL CHECK ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING ----_.-------------------- --- — — — — — — — — — — — — — --------- — — — HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO TYPICAL BUILDING THE ARCH ITECT'S/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR BULKHEAD SEE BASE BUILDING ARCHITECT t0 THE COMMENCEMENT OF ANY WORK 1 I I 1------� i---------*------ -----'--------- --------- ----- -----------------------:------- -- DRAWINGS FOR DETAILS 2. CEILINGS IN ALL AREAS SHALL BE INSTALLED IN STRICT AND HEIGHT. ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, AND SLATE AND LOCAL BUILDING CODES. I I I I 1 1 3. ALL LIGHT FIXTURE DIFFUSER, AND SPRINKLER HEAD LOCATIONS ARE PRELIMINARY UNTIL VERIFIED AND O ----+---------;---------i---------i----- ----------I--------------i---------i---------t------------------;----- -- -- -------------------- ---------------CHANGES I COORDINATED 33Y THE GENERAL CONTRACTOR � MADE t0 THIS PLAN MUST BE BROUGHT t0 THE � x T'S R'S TION PRIOR TO THE J I I 1 1 I I a � ' I I I I i I ' ' ' ARCHITEC /DESIGNS ATTENTION -------------------•------ - ---------i---- ---- COMM N OF ANY WORK N w --------------;----- E CEMENT � � � 4. CEILING HEIGHT THROUGHOUT THE SPACE IS V-&' AFF., . 53 yf W ---- -�-------------------------- -----------------------;--------- - EXCEPT AS NOTED ON THE DRAWINGS o BUILDING STANDARD H I I I i i I I ; -----, , m I ' I I J I I I 5. ALL DIMENSIONS l WHICH MAY BE LISTED ) ARE FROM Fx-' z Z $ W CENTERLINE t0 CENTERLINE OF FIXTURES. ' a ' ' H o 6. CEILING MATERIALS: SHALL BE BUILDING STANDARD 2'X 2 a c W �o ACOUSTICAL TILE UNLESS OTHERWISE NOTED. I ' ; ; ' 1 I 1 ' '------- '---------------- I----- '_________i_________i---______+______-________-_-1_________1_________T_________I 1 I __T______ ' I I I _T_________ T 1. SPRINKLER HEAD LOCATIONS AND QUANTITIES TO BE FIELD I ' ' I � I ' I I COORDINATED WITH CLECTRICAL LIGHTING AND MECHANICAL DIFFUSER AND GRILLES. INSTALLATION SHALL COMPLY WITH --------------- ----- --------- --------- I ' � ALL APPLICABLE CODES. SPRINKLERS t0 BE I , RECESSED -TYPE WITH WHITE COVERS I E, I I I � P D H DER � I I I I I I I I ' I I I 1 I ---------------- -------- i -- - - i --------i--------- ----- - -- 1---------1--- - 1-- -r--------- - .---------.------ ----------;--------;-------- TION AND QUANTITIES OF DIFFUSERS AND RETURN +-------- AIR GRILLESCA .::: M i RE TO BE CO-ORDINATED WITH THE HVAC I � I DESIGN / BUILD CONTRACTOR I I 1 --------i- 1---------1---------1---------I , I I ---------' I IC R1l.I 1 T_________T_________T_________i_________i_ I _________+_________' T_______-_T_________T_________T_________T______ �_________ _________ _________ I 1 I I I I I I 1 j lnt:i I ____-___i---------i_________________1---- .____1_________'--------- ' _ I I I 1 I I 1 I I i ' '-------------------------------____-- I 1 I I I I I T---------T---------T- CEILING FIXTURE KEY: t ;darn I I I , I I I I I I I I I I ----------- ---- I I I 1 ---------;---- -;--i---------+----- ------------- t--------- ;---------t -- : - ------ - ;---------;------- ------- BULDING STANDARD 2'x4' THREE LAMP, LAY -IN ---, I I FLUORESCENT LIGHT FIXTURE AND ELECTRONIC BALLAST I I I I I 1 I I I 1 I I 1 I I I I I I 1 I i 1 ---- -----------------+---------+---------+--------'-1---------1---------1---------'---------' -- ' ------T---------T---------T---------;---------;- T T- --T---------T---------T------ I I BUILDING STANDARD CEILING HUNG EXIT SIGN I I I I I 1 '------------ I I_______________________________________I 1 I_________T____-- , BUILDING STANDARD SUPPLY DIFFUSER r-----'--- I I ' 1 i I ' BUILDING STANDARD RETURN I I ------' i---------1 T--------- T------ I I I I i� BUILDING STANDARD SLOT DIFFUSER I I , I I I I I I I I I ' I I � W I I I _________1 ' I I ' i_________i______-__ ________ ___-__T_________ _________I i_________+- I I I T_________ T_________T______ I I I V I 1 I 1 1 I I 1 1 1 I i I I I I I 1 I I I ' i I 1 1________.' ' 1_________ 1_________i_________I_-_______'_________'_________'_________'______ I I I � Q � W m --a------------------------ I I ' , I I ; , _________1_____1----- i I I I I I I I 1 I I___.I1_____________ I I I I 1 I I 1 I I I I I I i I I I I I I I I I I I I I 1 I I 1 1 I 1 i 1 1 I I 1 I 1 1 1 I 1 I 1 I I I I ___-_____1_________L___ I I I 1 I I I , I ' I 1 I 8 I I 1 I I I I I I I - 2 I 1 I 1 GYP BD I I I I I ----- I I I I I I 1 I I T--r--�--T— AREA OF WORK 1 I � O I I I I I I I I I I I I I 1 I I I I I I I I I I 1 1 I I ; I I I I 1 I -----------1---------1---------------------------'--------- --------- ---------+--------- --------- ---------T-- + + CO ' Ijill LLLLJ _________+_________1_________i_________T_________i_________' '_________I _____________ _ --- --------- _________+_____--__' --------------_____+__ 7 i.M.i. I U I 1 I I I ; I I � � � i � I '-' • I I 1I 1 I °� _________ '--------- __________�_________'._________r ____-r_________�________�_________I__________ �L r'-I'CI]Ii I +«N�ni �Tr N Q ---- I-- REFLECTED Q CEILING PLAN & J �z P16 1X- 1'-0' CL o v N W D I W H a 0 DRAWING N0. LOCATION FLOOR PLAN ws A 0 NOW`4 TITLE: RM m I !f I a a a w ELECTRICAL KEY: 0 DUPLEX OUTLET, 18' AFF. DUPLEX OUTLET, 18' AFF., DEDICATED CIRCUIT DED. o ELECTRICIAN TO DETERMINE CORRECT VOLTAGE AND OTHER NEEDS FOR SPECIFIC APPLIANCE OR INSTRUMENT T DATA/COMMUNICATION OUTLET AT 18' AFF. POWER POLE FOR DATA AND ELECTRICAL POLE TO FEED ELECTRIFIED FURNITURE ® PANELS SUPPLIED BY TENANT ELECTRICAL & COMMUNICATIONS PLAN A810 1/V- 1'-V ELECTRICAL PLAN NOTES: APPLY THIS SHEET ONLY. OCONTRACTOR TO SUPPLY TELECOM CABINET FOR TENANTS DATA AND TELECOM EQUIPMENT, AS REQUIRED. GENERAL NOTES: 1. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS, AND STANDARDS INCLUDING BUT NOT LIMITED TO THE INDIANA BUILDING CODE, THE INDIANA HANDICAPPED CODE, THE INDIANA PLUMBING, MECHANICAL, AND ELECTR--AL CODES, THE INDIANA FIRE CODE, THE AMERICANS WITH DISABILITIES ACT (ADA), AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITION. 2. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR TO START OF WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER IMMEDIATELY. 3. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS REQUIRED FOR THE COMPLETION OF THE PROJECT. 4. ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF THE OWNER'S FIXTURES, FURNISHINGS, AND EQUIPMENT. 5. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FINISHED FACE OF WALLS. 6. ALL DIMENSIONS REQUIRED ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER DO NOt SCALE DIMENSIONS. 1. FINISHED DOOR OPENINGS IN ALL NEW PARTITIONS SHALL BE SET TO ALLOW FULL TRIM EXPOSURE (4' MIN.) FROM ADJACENT PERPENDICULAR PARTITION, UNLESS NOTED OTHERWISE. 8. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT. S. ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED WITH THE ARCHITECT/DESIGNER AND LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION. ELECTRICAL NOTES: I. ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS, AND NATIONALLY ACCEPTED CODES AND STANDARDS. 2. ELECTRICAL CONTRACTOR TO COORDINATE SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS OF TENANTS AS SPECIFICALLY INDICATED ON DRAWINGS. VERIFY ACTUAL REQUIREMENTS WITH ARCHITECT/DESIGNER PRIOR TO !NSTALLATION. 3. ALL WIRE AND CABLE SHALL BE 'B5% CONDUCTIVITY COPPER, UNLESS OTHERWISE REQUIRED. 4. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. 5. ALL OUTLET BOXES ARE TO BE SHERADIZED STEEL WITH PATTERNS AS REQUIRED. 6. ALL WIRING DEVICES TO BE SPECIFICATION GRADE BY ARROWHART, HUBBELL, PASS t SEYMOUR, OR SIERRA. 1. ALL DUPLEX RECEPTACLES ARE TO BE 20a. RATED WITH 'U' stn .:...:.:.:.::.::..::::.:.:.. D x SHAPED GROUNDING SLOT. w 8. CONTRACTOR TO PROVIDE MUD RING AND PULL STRING AT a �, TELEPHONE AND COMPUTER LOCATIONS AS INDICATED ON p I '� cd PLANS. COMPLETE TELEPHONE AND COMPUTER SYSTEMS o4 � W L;' (MATERIAL AND LABOR) ARE PROVIDED BY TENANT UNLESS 0-4 � W OTHERWISE INDICATED. W U z o W 9. ALIGN ALL THERMOSTATS VERTICALLY ABOVE SWITCHES AT a ' R La 60' AFF. COORDINATE WITH MECHANICAL CONTRACTOR IF A z a N THERMOSTAT IS NEEDED WHERE A SWITCH DOES NOT OCCUR, " ~ ``' a U COORDINA'T'E LOCATION WITH TENANT. 13. ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALL BE INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS. 14. PROVIDE EMERGENCY STROBES AND HORNS AS REQUIRED BY STATE AND LOCAL BUILDING CODES. 15. CONTRACTOR IS TO COORDINATE PLACEMENT OF EXIT stn .:...:.:.:.::.::..::::.:.:.. D LIGHTS WITH ENGINEER, FIRE OFFICIAL, AND ARCHITECT/DESIGNER ALL EXIT LIGHTING TO BE BUILDING STANDARD. m 0 W Li H W U AREA OF WORK I r--L--� &Pl LOCATION FLOOR PLAN ws Q U z Q z u - W Q 0 DRAWING N0. TITLE: am/ N co 0 CO ,I. :4 G) I r® NQ Wz �a DO (j)z r•� u �J:'] a r I I 0 I