Loading...
HomeMy WebLinkAboutC812-SITE-DETAILS-Rev.2™ Phone (888) 344-9044 Fax (423) 826-2112 2719 Kanasita Drive, Chattanooga, TN 37343 STORMWATER TREATMENT SOLUTIONS www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-11 Horseshoe PCS Standard Detail AS-11 PCS STD 02/03/14 Scale: Drawn By: Document: Date: TAG 1:30 U.S. Patent No. 6524473 and other Patent Pending * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. ** Orientation may vary from 90°, 180°, or custom angles to meet site conditions. 4 1/2" [114 mm] 1/2" [13 mm] 1" [25 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 1" [25 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 48" [1219 mm] Min. 12" [305 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete 8" [203 mm] Gravel Backfill Gravel Backf ill Plan View Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System Arched Baffle Gravel Backfill shall extend at least 3.5 feet outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Inlet A Arched Baffle Octagonal Base Plate Outlet A Vent Section A-A Bedding Undisturbed Soil Backfill 4 1/2" [114 mm] Cover Frame 1" [25 mm] Thick Expansion Joint 30" [762 mm] Material Riser #4 [13 mm] Rebar @ 6" [152 mm] Each Way 14" [356 mm] 1/2" [13 mm] 3,000 psi [20 MPa] (min) Concrete Manhole Frame & Cover Detail For Traffic Loading Areas NTS If traffic loading (H-20) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch [25 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Backfill (90% Proctor Density) 48" [1219 mm] Grade (Rim) Vent Slide riser over top ring and bolt in 4 places Riser Rim elevations to match finished grade. PCS risers should NOT be field cut by Contractor. Manhole Frame and Cover by Manufacturer. (See Details) Top Reinforcement Top Reinforcement Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Swirl Inlet Swirl Outlet STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ ACTUAL CONFIGURATION SHALL BE A TIGHT HORSESHOE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW DETAIL - AS-11 AND WQ-1 DETAILS NTS PLAN VIEW SECTION A-A A A JCT NTS GLR 8 A B 7 6 5 4 3 2 1 C D E F G H 8 7 6 5 4 3 2 1 A B C D E F G H NO DATE DESCRIPTION REVISION RECORD 1 11/10/17 ISSUED FOR CONSTRUCTION 2 12/08/2017RESUBMITTAL REVISIONS 3 12/22/2017RESUBMITTAL REVISIONS 4 01/15/2018RESUBMITTAL REVISIONS 530 E. Ohio Street · Suite G - Indianapolis, IN 46204 5 01/22/2018BICYCLE STORAGE RESPONSE 317-655-7777 · 877-746-0749 www.cecinc.com DATE: DWG SCALE: DRAWN BY: CHECKED BY: APPROVED BY: PROJECT NO: SHEET OF DRAWING NO.: 172-019 JANUARY 23, 2018 39 DILLON CONSTRUCTION GROUP MIDTOWN WEST BARRETT & STOKELY / MERCHANTS BANK 2ND STREET & 3RD AVENUE SW CARMEL, INDIANA P R O F E S S I O N A L E N G I N E E R I N D I A N A A A R O N C . H U R T PE10300058 STATE OF - N o R E G I S T E R E D * HAND SIGNATURE ON FILE 6 01/23/2018RESUBMITTAL REVISIONS SITE DETAILS C812 35 05/01/18 Nick Mishler