Loading...
HomeMy WebLinkAboutE-000-ELECTRICAL-SYMBOLS-&-ABBREVIATIONS-Rev.2SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CLIENT ARCHITECT 17105 NOVEMBER 15, 2017 CONSTRUCTION SET MERCHANTS CORPORATE CENTER CARMEL, IN E-000 ELECTRICAL SYMBOLS & ABBREVIATIONS a SHEET TYPE DESIGNATORS MATCH_LINE REFER TO ADDITIONAL FLOOR PLAN OVERLAP BEYOND AREA EXTENSION PLAN NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECT SCALE: DRAWING BLOCK TITLE 1/8" = 1'-0" ONE-LINE IDENTITY SYMBOLS CIRCUIT BREAKER (OPEN), "xxAF" INDICATES FRAME SIZE, CAPACITOR "yyAT" INDICATES TRIP SIZE CIRCUIT BREAKER (ENCLOSED), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" "yyAT" INDICATES TRIP SIZE, "zzA" INDICATES FUSE LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER. WITH RATING OPENING) CLOSING) DISCONNECT SWITCH UNFUSED FUSED CUTOUTS, "zzA" INDICATES FUSE RATING CURRENT TRANSFORMER CABINET INDICATES FUSED RATING DISCONNECT SWITCH AIR BREAK WITH FUSE,"zzA" OVERLOAD RELAY FUSE, "zzA" INDICATES FUSED RATING KIRK KEY INTERLOCK SYSTEM PHASES MOTOR AND LABEL, "3" DENOTES HORSEPOWER LIGHTNING ARRESTER AND GROUNDING TO PROTECT ALL MOTOR OPERATOR FOR CIRCUIT BREAKERS OR SWITCH NETWORK PROTECTOR PANEL BOARD POTHEAD SHUNT TRIP STRESS CONE RESISTOR PROTECTION GROUND FAULT CIRCUIT INTERRUPTER, PERSONNEL MAGNETIC STARTER WITH NEMA SIZE INDICATED GENERATOR "400-5A" INDICATED RATIO CURRENT TRANSFORMER, "3" INDICATES QUANTITY, POTENTIAL TRANSFORMER, "3" INDICATES QUANTITY CORNER GROUNDED DELTA 3-PHASE, 3-WIRE DELTA CONNECTION 3-PHASE, 4-WIRE WYE CONNECTION (GROUNDED ADJUSTABLE FREQUENCY DRIVE 3 REFERENCES DETAIL BUS DUCT OR BUS WAY NUMBER WIRE WAY TRANSFER SWITCH A xxAF yyAT xxAF yyAT yyAT xxAF yyAT xxAF yyAT 2 zzA zzA zzA CT K2 zzA PANEL 3 GFCI ST (3) ( 3) 400-5A AFD 3 xx-x-x M DUPLEX CONVENIENCE RECEPTACLE. 20A 125V. WALL POWER IDENTITY SYMBOLS SINGLE CONVENIENCE RECEPTACLE MOUNT DEVICE DOUBLE DUPLEX CONVENIENCE RECEPTACLE. SINGLE CONVENIENCE RECEPTACLE ON DUPLEX CONVENIENCE RECEPTACLE ON DOUBLE DUPLEX CONVENIENCE RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT EMERGENCY/STANDBY CIRCUIT CLOCK HANGER OUTLET RECESSED MOUNTED 8'-0" AFF EMERGENCY/STANDBY CIRCUIT SPECIAL RECEPTACLE MULTI-OUTLET ASSEMBLY OR 8" BELOW CEILING AS INDICATED MULTI-OUTLET ASSEMBLY FLOOR DUPLEX CONVENIENCE RECEPTACLE. FLUSH MOUNT FLOOR BOX, ADJUSTABLE, WITH BOTH POWER AND VOICE/DATA RECEPTACLES JUNCTION BOX MOTOR PUSH-BUTTON ON/OFF PUSH-BUTTON STATION THREE FUNCTION PUSH-BUTTON SWITCH PADLOCK CAPABILITY, "P"-INDICATES PILOT LIGHT TOGGLE DISCONNECT SWITCH THERMAL MOTOR SWITCH WITH HANDLE GUARD AND DISCONNECT SWITCH, FUSED TYPE DISCONNECT SWITCH, UNFUSED TYPE ENCLOSED CIRCUIT BREAKER MAGNETIC CONTACTOR MAGNETIC MOTOR STARTER COMBINATION MAGNETIC STARTER AND DISCONNECT SWITCH PHASE, PHASE, PHASE, GROUND PHASE, PHASE, NEUTRAL, NEUTRAL, GROUND HOMERUN PHASE, PHASE, PHASE, NEUTRAL, GROUND GROUND S S D P C W/O IDENTITY SYMBOLS SWITCHBOARD METER DEMAND METER (UTILITY) WEATHERPROOF WATTHOUR METER (UTILITY) LEG ETC. NOM CUSTOMER METER SYMBOLS WM D SWITCH IDENTITY SINGLE POLE/DOUBLE THROW SWITCH HORIZONTALLY MOUNTED-WITH ON POSITION TO THE LEFT SWITCH (EDIT AS NEEDED FOR 2-WAY, 3-WAY, OR a SWITCH (EDIT AS NEEDED FOR 2-WAY, 3-WAY, a SWITCH SINGLE POLE SWITCH SWITCH LEG ETC. CIRCUIT BREAKER SWITCH LOW VOLTAGE SWITCH DIMMER SWITCH. RATED 1000W, UNLESS OTHERWISE SWITCH IS ON GLOW SWITCH TOGGLE, GLOWS IN OFF POSITION V OVERRIDE SWITCH MISC WEATHERPROOF SINGLE POLE SWITCH SWITCH WITH PILOT LIGHT ON WHEN SWITCH IS ON MULTIPLE SWITCHES WIRED IN PARALLEL MIN OCCUPANCY SENSOR, CEILING MOUNTED, "P"- INDICATES TEMPERATURE ABBREVIATIONS AND TERMS Ø EWC ELECTRIC WATER COOLER A/C PHASE EXISTING FCU °F OL A EX OVERLOAD OUNCE OWNER FURNISHED/CONTRACTOR INSTALLED P OZ DEGREES FAHRENHEIT FOOT, FEET AIR CONDITIONING ACCU ID AMPERE FUSE POLE AFC BRAKE HORSEPOWER RPS AF PH PHASE G ABOVE FINISHED COUNTER FURN FURNACE POUNDS PER SQUARE INCH HO REV PSI FT RCPT PSIA POUNDS PER SQUARE INCH ABSOLUTE PTAC AFF ABOVE FINISHED FLOOR GROUND AIR HANDLING UNIT GC POUNDS PER SQUARE INCH GAUGE PACKAGED TERMINAL AIR CONDITIONER AHU AMPERES INTERRUPTING CAPACITY AVERAGE GFI FPVAV GROUND FAULT INTERRUPTING PSIG FLOOR AMERICAN NATIONAL STANDARDS INSTITUTE HAND-OFF-AUTOMATIC ARCHITECT ANSI HEATING HOT WATER PUMP OF/CI AVG OCCUPANCY SENSOR, WALL MOUNTED WITH OFF-AUTO RM REVOLUTIONS PER MINUTE HHWP ARCH TIMER SWITCH HUB OUTLET RECEPTACLE LOW VOLTAGE MASTER SWITCH HORIZONTAL REVOLUTIONS KEY OPERATED SWITCH WITH PILOT LIGHT ON WHEN KEY OPERATED SWITCH ROOM B/I HORSEPOWER RTU BOTTOM ELEVATION HOA SQUARE FOOT HR HORIZ CONNECTION RPM PHASE, NEUTRAL, GROUND, HOMERUN BE HP HOUR(S) REVOLUTIONS PER SECOND ROOF TOP UNIT BYPASS ISOLATION BUILDING HEATING ONLY ROOFTOP UNIT SF ST BRITISH THERMAL UNIT PER HOUR BSMT INSIDE DIAMETER BASEMENT BHP SQUARE CHILLER C CCW CIRCUIT BREAKER TO REMAIN CHWP STANDARD INVERT INT COND INV SW KELVIN CHILLED WATER PUMP TBR TO BE REMOVED CB K CLG SHUNT TRIP CH KILOWATT COMPRESSOR COOLING TOWER LBS CONDENSER MAXIMUM POUNDS TOP ELEVATION CONVECTOR UH TO BE INSTALLED CABINET UNIT HEATER MAX MBH MCA TRANSFER FAN TRANSFORMER, DRY TYPE, UNLESS OTHERWISE INDICATED MINIMUM CIRCUIT AMPS LTG CONDENSING UNIT TR CU TYP TF TRANS UNIT HEATER CUV CW MANUFACTURER MINIMUM MC DIRECT CURRENT CLASSROOM UNIT VENTILATOR MFR VOLTS DC VAV UV DISCONNECT SWITCH VB UNIT VENTILATOR MTD VARIABLE AIR VOLUME NATIONAL ELECTRIC CODE VFD VACUUM BREAKER W/ EACH INTERCOM UNIT - FLUSH MOUNT DRAWING DEDICATED CIRCUIT EF VARIABLE FREQUENCY DRIVE EL WIRE, WATT DED SYMBOLS WITH SECURITY IDENTITY ELECTRICAL CONTRACTOR NOMINAL OD EFF EC DOOR CHIME ETR NON-LINEAR DOOR BUZZER CAMERA CCTV COAXIAL CABLE OUTLET AND POWER OUTLET WITHOUT DOORBELL MASTER INTERCOM AND DIRECTORY UNIT ELECTRIC DOOR OPENER OUTSIDE DIAMETER, OVERFLOW DRAIN SECURITY DOOR ALARM MAGNETIC LOCK SECURITY CARD READER. "WP" INDICATES AMPERES ELECTRIC DOOR STRIKE AIC MOTION DETECTOR SECURITY CONTROL PANEL BLDG WEATHER-PROOF SECURITY EXIT PUSH BUTTON CWP SECURITY KEYPAD SECURITY DOOR CONTACTS IDENTITY SYMBOLS EQUIPMENT RACK-WALL MOUNTED TELEPHONE/DATA OUTLET DATA OUTLET FLOOR TYPE TELEPHONE/DATA OUTLET FLOOR TYPE MASTER ANTENNA SYSTEM OUTLET (MATV) DATA OUTLET SPEAKER BI-DIRECTIONAL PAGING-CEILING MOUNTED SPEAKER-CEILING MOUNTED TELEPHONE OUTLET FLOOR TYPE SPEAKER HORN CALL IN SWITCH MICROPHONE OUTLET-WALL MOUNTED TELEPHONE OUTLET-WALL MOUNTED CABLE ANTENNA SYSTEM OUTLET (CATV) TERMINAL CABINET WITH 3/4" PLYWOOD BACKING EQUIPMENT RACK-FREE STANDING INTERCOM UNIT-FLUSH MOUNTED TELEPHONE OUTLET MASTER INTERCOM AND DIRECTORY UNIT EQUIPMENT CABINET PLYWOOD BACKBOARD SHEET FOR CONTINUATION STROBE UNIT ONLY CARBON MONOXIDE DETECTOR. LINE VOLTAGE WITH AREA TYPE SMOKE DETECTOR USED AT DUCT WORK OPENING BATTERY BACKUP MANUAL PULL STATION BEAM SMOKE DETECTOR, "R"-INDICATES RECEIVER FLAME DETECTOR MOTOR OPERATED FIRE/SMOKE DUCT DAMPER WORK OPENING HORN AND STROBE DUCT SMOKE DETECTOR WITH TWO AUXILIARY CONTACTS SMOKE DETECTOR BEAM SMOKE DETECTOR, "S" INDICATES SENDING UNIT END-OF-LINE RESISTOR ELEVATOR RECALL WITH AUXILIARY CONTACTS SPEAKER AND STROBE TAMPER SWITCH, BY DIVISION 15 AUTOMATIC HEAT DETECTOR, "R" INDICATES RATE OF RISE SELF CONTAINED SMOKE DETECTOR-SINGLE STATION TYPE LOW PRESSURE SWITCH, BY DIVISION 15 TEMPERATURE 190°F AUTOMATIC HEAT DETECTOR, "F" INDICATES FIXED WATER FLOW SWITCH, BY DIVISION 15 HYDROGEN DETECTOR POST INDICATOR VALVE, BY DIVISION 15 F FIRE ALARM COMM IDENTITY SYMBOLS DRILL KEY SWITCH CODE TRANSMITTER FIRE ALARM MASTER BOX CONTACT CLOSURE) INDIVIDUALLY ADDRESSABLE MODULE- RELAY (PROVIDES AIR SAMPLING CONTROL/DETECTOR PANEL WITH KEY REPOSITORY (KNOX BOX) ASSOCIATED AIR SAMPLING PIPING NETWORK FIRE ALARM ANNUNCIATOR PANEL, 2 LINES OF 4° FIRE ALARM TERMINAL CABINET CHARACTERS LCD DISPLAY VOICE EVACUATION PANEL ADDRESS FOR CONTACT) FIRE FIGHTER'S PHONE INDIVIDUALLY ADDRESSABLE MODULE- MONITOR (PROVIDES FIRE ALARM CONTROL PANEL MOTOR CONTROL CENTER (MCC) TRANSPONDER BATTERY PACK AND CHARGER LIGHTING OR POWER PANEL, RECESSED DISTRIBUTION PANEL DISTRIBUTION IDENTITY FEEDER TRANSFORMER-PAD MOUNT LIGHTING OR POWER PANEL, SURFACE SYMBOLS METER DRY TYPE TRANSFORMER LIGHTING OR POWER PANEL ON NORMAL/GENERATOR DISTRIBUTION PANEL ON NORMAL/GENERATOR FEEDER CURRENT TRANSFORMER CABINET SURFACE MOUNTED 1'x4' FIXTURE TRANSFER SWITCH T METER AND SOCKET GENERATOR LIGHTING IDENTITY SYMBOLS RECESSED MOUNTED 1'x4' EMERGENCY FIXTURE SURFACE MOUNTED 2'x4' FIXTURE SURFACE MOUNTED 2'x4' EMERGENCY FIXTURE T RECESSED MOUNTED 2'x4' EMERGENCY FIXTURE SUSPENDED FIXTURE RECESSED MOUNTED 2'x4' FIXTURE RECESSED MOUNTED FIXTURE RECESSED MOUNTED 1'x4' FIXTURE SURFACE MOUNTED EMERGENCY FIXTURE SURFACE MOUNTED FIXTURE DETERMINED BY JOB SPECIFICATION SUSPENDED EMERGENCY FIXTURE POLE MOUNTED FIXTURE SURFACE MOUNTED 1'x4' EMERGENCY FIXTURE WALL MOUNTED FIXTURE RECESSED MOUNTED EMERGENCY FIXTURE LUMINAIRE STRIP TYPE FIXTURE (3 FOOT) POLE MOUNTED EMERGENCY FIXTURE INDICATED ON DWGS (MOUNTING HEIGHTS TO BE EXIT LIGHTING FIXTURE, ARROWS AND EXIT FACE AS VOLUME CONTROL SPEAKER BI-DIRECTIONAL PAGING-WALL MOUNTED WALL MOUNTED EMERGENCY FIXTURE SPEAKER-WALL MOUNTED EMERGENCY BATTERY REMOTE LIGHTING HEADS LUMINAIRE STRIP TYPE FIXTURE (2 FOOT) MICROPHONE OUTLET-FLOOR MOUNTED SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE ROADWAY LUMINAIRE-COBRA HEAD WALL MOUNTED FIXTURE WALL MOUNTED EMERGENCY FIXTURE BOLLARD TYPE SITE LIGHTING FIXTURE FIXTURE-DOUBLE OR SINGLE HEAD SPOT LIGHT COMMUNICATION EMERGENCY BATTERY UNIT WITH LIGHTING HEADS SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE LUMINAIRE STRIP TYPE FIXTURE (4 FOOT) NUMBER OF LIGHTS INDICATED ON DWGS AND SCHEDULE CCTV MONITOR OUTLET IN-GROUND OR FLOOR MOUNTED FIXTURE EXISTING TO REMAIN SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE CCTV CAMERA "WP" INDICATES WEATHER-PROOF EXTERIOR LIGHT TRACK, LENGTH AS INDICATED ON DWGS WITH EFFICIENCY NTS NOT TO SCALE EXHAUST FAN ELEVATION W NOT IN CONTRACT WP NL NIC NEC VF VENTILATION FAN NA NOT APPLICABLE VERT VERTICAL MEDIUM VOLTAGE CONDENSER WATER PUMP MV MISCELLANEOUS MOUNTED CLOCKWISE AUTO/MANUAL UON UNLESS OTHERWISE NOTED MCC MOTOR CONTROL CENTER CM TYPICAL N MECHANICAL CONTRACTOR TRANSITION TEMP THOUSAND Btu PER HOUR LIGHTING TE L CEILING TBI TWIN LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE kW COUNTERCLOCKWISE SWITCH INTERIOR STD CONDUIT IN INCH, INCHES SPEC SQ Hz HERTZ SPECIFICATION HRTU GENERAL CONTRACTOR E FAN POWERED VAV UNIT PE PNEUMATIC ELECTRIC FLR FAN COIL UNIT INDICATED. "LV" = LOW VOLTAGE "FL" = FLUORESCENT MOMENTARY CONTACT SWITCH XX' xxxV BUS DUCT PHASE, PHASE, GROUND PHASE, PHASE, NEUTRAL, GROUND PHASE, NEUTRAL, GROUND (UP/DOWN/STOP) MOTOR STARTER SWITCH XX' xxxV WIRE WAY xxA-xP xxx KVA xxxV xØ xW PRI NEUTRAL) GROUNDING CONNECTION-SYSTEM AND OR EQUIPMENT CONTACT NORMALLY CLOSED (NC) ("TO"-WITH TIMED CONTACT NORMALLY OPEN (NO) ("TC"-WITH TIMED CURRENT LIMITING FUSES, "xxAF" INDICATES FRAME SIZE, TRANSFER SWITCH INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE PRIMARY DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" FIRE ALARM IDENTITY SYMBOLS AIR COOLED CONDENSING UNIT 1 BtuH COMPR MO CONV CT CUH XX-XX-X-X DS DWG EA CONTROL RELAY CONTROL RELAY HORN UNIT ONLY REMOTE STATION FOR DUCT DETECTOR USED AT DUCT SMOKE DETECTOR-VISUAL AND AUDIBLE SIGNAL T xxxY/xxxV xØ xW SEC x xxxV xØ # G 0 xxx KW A. 16' GENERAL ELECTRICAL NOTES ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL xxAF GENERATOR INDIANA ELECTRICAL CODE AMENDMENTS, LOCAL/MUNICIPAL CODES, APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. THAN 12" IN LENGTH, NOR GREATER THAN 36" IN LENGTH. 8' ELECTRICAL CODE - LATEST EDITION ADOPTED BY INDIANA, THE DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE C. D. AND THE AUTHORITY HAVING JURISDICTION. F. VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT LESS E. B. ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR CONDUIT SEALING MATERIAL. 4' ARE ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE ALL CABLE SIZES SHALL UTILIZE COPPER CONDUCTORS. ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS MANUFACTURER'S WRITTEN RECOMMENDATIONS. AUTO TRANSFER SWITCHES AND THEIR SOURCES/LOADS, BETWEEN I. SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS FEEDERS FROM PANEL BOARDS BACK TO MAIN SWITCHBOARD, BETWEEN DRY-TRANSFORMERS AND THEIR SOURCES/LOADS. ARE NOT INDICATED G. CANNOT BE INSTALLED DUE TO CONFLICT WITH STRUCTURE OR OTHER CONFLICTS IN THESE LOCATIONS. EQUIPMENT, THE CONTRACTOR SHALL PROVIDE (2) 4" C. WITH INSULATED BUSHINGS THAT OVERLAP 1" INTO THE TRAY TO AVOID CABLE TRAY IS SHOWN ON THE PLANS. IF PORTIONS OF CABLE TRAY ON THE FLOOR PLAN DRAWINGS. FEEDERS AND SHALL BE SIZED AS INDICATED ON THE ONE LINE DIAGRAM. H. PART OF THE WORK, K. (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) ON THE CONTRACT DRAWINGS. SINGLE PHASE BRANCH CIRCUIT HOME DRAWING MODULE LOCATION J. USE LINK-SEALS. CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL GRAPHIC SCALE GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS, RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT HOME RUNS SHALL NOT BE COMBINED IN A RACEWAY UNLESS SHOWN AND A GROUNDING CONDUCTOR. NEUTRAL BACK TO THE PANEL. EACH SINGLE PHASE BRANCH CONDUCTOR SHALL HAVE A DEDICATED MORE THAN 6 INCHES FROM CABINETS, BOXES, FITTINGS, OUTLETS, WHERE LOW VOLTAGE (CONTROL) CABLING IS ALLOWED TO BE NUMERIC SCALE INSTALLED WITHOUT A RACEWAY, IT SHALL BE SUPPORTED PER L. SECTION 260523 NOT EXCEEDING INTERVALS OF 48 INCHES, AND NOT RACKS, FRAMES AND TERMINALS. N MODULE SUBSET DESIGNATORS GENERAL PLUMBING G-000 FIRE PROTECTION SHEET A-000 M-000 NORTH ARROW ARCHITECTURAL F-000 P-000 E-000 MECHANICAL ELECTRICAL IN DRAWING MODULE SECTION LOCATION PLAN SECTION LOCATION AT SUBSET SHEET EXTENSION DETAIL LOCATION IN BEYOND AREA SUBSET SHEET DRAWING MODULE REFERENCE SYMBOLS REFERENCE SECTION LOCATION THROUGH AN AREA FOR DETAIL LOCATION AT LARGE SCALE VIEW LOCATION SECTION INDICATOR: INFORMATION. REFERENCE DETAIL LOCATION FOR ADDITIONAL KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL ADDITIONAL INFORMATION. INFORMATION. DETAIL INDICATOR: IN DRAWING MODULE MATCH LINE INDICATOR: MODULE TITLE INDICATOR: AT SUBSET SHEET LARGE SCALE VIEW LOCATION ADDITIONAL INFORMATION. DRAWING BLOCK SHEET REFERENCE DRAWING MODULE LOCATION FOR REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. LIGHTING INDICATOR: REVISION INDICATOR: SHEET REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. MODULE "A" = FIXTURE TYPE, REFER TO FIXTURE SCHEDULE, "2" = CIRCUIT NUMBER, "a" = SWITCH IDENTIFICATION REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. REVISION CLOUD REVISION INDICATOR # # # # KEYNOTE INDICATORS NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES AREA LEADER NOTATION DESIGNATORS WITHIN THE DRAWING SET. GENERAL ELECTRICAL GENERAL NOTES: LINE LEADER NOTES: NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN GENERAL SHEET NOTES: THE DISCIPLINE. POINT LEADER NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR. RELATES TO ITEM TO IDENTIFY ITEMS. WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR NUMERICAL CHARACTER E-000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES) E-100 PLANS E-200 SECTIONS ELEVATIONS E-300 E-400 LARGE SCALE VIEWS (PLANS, ELEVATIONS OR SECTIONS) SCHEDULES OR DIAGRAMS E-500 DETAILS E-600 E-700 USER DEFINED E-800 USER DEFINED E-900 3D REPRESENTATIONS (ISOMETRICS) M P C # F CB M B B B W F H S F S M K M. ALL FEEDER CONDUCTORS SHALL BE ALUMINUM WHILE ALL BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER. UNDERGROUND AND CONCRETE ENCASED RACEWAYS SHALL BE RNC (SCHED. 40 PVC). EXPOSED RACEWAYS SHALL BE IMC OR EMT. MC CABLE MAY BE USED WHERE CONCEALED IN WALLS AND CEILINGS N. ALL LISTED SHORT CIRCUIT RATINGS FOR DISTRIBUTION EQUIPMENT ARE ESTIMATED. PROVIDE ARCHFLASH AND COORDINATION STUDIES OF SYSTEM TO DETERMINE FINAL VALUES. 05/01/18 Nick Mishler