HomeMy WebLinkAboutE-501-ELECTRICAL-DETAILS-Rev.2SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CLIENT ARCHITECT 17105 NOVEMBER 15, 2017 CONSTRUCTION SET MERCHANTS CORPORATE CENTER CARMEL, IN E-501 ELECTRICAL DETAILS W 96" EXIT 96" 48" 48" 72" 48" 36" 20" 20" 20" NOTE 2 20" 20" 96" 96" 72" 96" 48" 20" 48" 48" 84" WC NOTES: 1. EQUIPMENT MOUNTING HEIGHTS SHALL BE INDICATED UNLESS OTHERWISE NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS. 2. CONCEAL RECEPTACLE BEHIND WATER COOLER. VERIFY EXACT MOUNTING HEIGHTS. 3. WHERE DEVICES ARE LOCATED IN MASONRY WALLS LOCATE DEVICE WITHIN COARSING SO THAT MOUNTING INDICATED HERE IN IS NOT EXCEEDED. 4. ALL RECEPTACLES ABOVE KITCHEN COUNTER AND NEAR BATH VANITIES SHALL BE INSTALLED HORIZONTALLY AT +44" AFF TO TOP OF THE BOX. SYMBOLS: FLOOR CEILING SCALE: ELECTRICAL ELEVATION 1 NONE D M F H S F S J C S M SCALE: NONE LAY-IN FIXTURE SUPPORT DETAIL 1. LIGHTING FIXTURES SHALL BE SUPPORTED INDEPENDENTLY OF CEILING SYSTEM. UPON WRITTEN REQUEST TO THE ENGINEER, OTHER MEANS OF SUPPORT WILL BE CONSIDERED FOR APPROVAL. NOTE: FLEXIBLE CONDUIT DOUBLE LOOP SAFETY CHAIN MIN. 2 PER FIXTURE ANGLE IRON OR SLOTTED CHANNEL AS REQUIRED SECURELY SUPPORTED FROM STRUCTURE ABOVE CADDY CLAMPS OR EQUAL OUTLET BOX & SUPPORT ROD CEILING T-BAR CEILING LAY-IN TYPE FIXTURE STRUCTURE 2 4" OCTAGONAL JUNCTION BOX (AT LEAST 1.5" DEEP). DO NOT INSTALL SENSOR WITHOUT JUNCTION BOX. CEILING DEPLUGGABLE TERMINAL SENSOR (2) MOUNTING SCREWS FRONT COVER SCALE: TYPICAL OCCUPANCY SENSOR MOUNTING DETAIL 3 NONE SCALE: NONE LAY-IN CEILING EXIT SIGN MOUNTING DETAIL STEEL JOIST OR BEAMS ADDITIONAL ROD OR WIRE SUPPORT 1/FIXTURE. ADJUSTABLE SUPPORT BRACKET, 2/FIXTURE (ATTACH TO CEILING CHANNELS) TIE WIRE LAY-IN CEILING FIXTURE LAY-IN CEILING CHANNELS 4 SCALE: TYPICAL FLUSH MOUNTED SYSTEMS OUTLET 5 NONE CONDUIT STUBBED TO NEAREST CABLE TRAY ON SAME FLOOR AS OUTLET. SEE OUTLET DETAILS ON E501 FOR CONDUIT SIZES. FACEPLATE. FLUSH MOUNTED, 3" DEEP, 4" OR 4-11/16" SQUARE BOX. PROVIDE WITH SINGLE-GANG PLASTER RING IN GYPSUM BOARD OR PLASTER FINISHED WALL. PROVIDE 3-1/2 INCH DEEP MASONRY BOX IN MASONRY WALL. SCALE: NONE FIRE/SMOKE DAMPER WIRING DETAIL 1. SEE FIRE ALARM DRAWINGS AND POWER PLANS FOR LOCATIONS OF SMOKE DAMPER, DUCT DETECTOR, AND PANEL/BRANCH CIRCUIT PANEL NUMBER. 2. ALL EQUIPMENT SHOWN DARK BY DIVISION 26 OR 28. ALL EQUIPMENT SHOWN SHADED BY OTHER DIVISION. NOTES: BRANCH CIRCUIT CONDUIT/WIRING TO NEXT FIRE/SMOKE DAMPER BRANCH CIRCUIT CONDUIT/WIRING TO NEXT ADDRESSABLE DEVICE 4 WIRE FIRE ALARM NETWORK CIRCUIT FROM FACP BRANCH CIRCUIT CONDUIT/WIRING STANDBY POWER PANEL FROM 208/120V LEGALLY-REQUIRED DUCT DETECTOR FIRE/ SMOKE DAMPER DUCT OUTLINE AIRFLOW DIRECTION DUCT OUTLINE 7 PER ONE LINE DIAGRAM A SINGLE RACEWAY) (MAY BE COMBINED IN 2#14, 3/4"C. TELE. CABLE NOTES: TELE. OUTLET SECOND LOBBY FLOOR IN HOISTWAY IN ELEVATOR PIT FIRST LOBBY FLOOR #18 SHIELDED INDUSTRIAL VAPORTITE IN PIT FIXTURE RECEPTACLE GFI POWER FEED, SIZED 480V, 3Ø ELEVATOR 2#12,#12G., 3/4"C. MANUFACTURER/ INSTALLER CAB CAB HVAC CONTROL CAB LIGHTS BY DIVISION 26 BY ELEVATOR TO 480V PANEL PER PLANS CB CB IN HOISTWAY EQUIPMENT ROOM IN ELEVATOR FIRST FLOOR LOBBY BY DIV. 16 TWISTED PAIR FLOOR LOBBY THIRD SECOND FLOOR LOBBY FOURTH FLOOR LOBBY FLOOR LOBBY THIRD FLOOR LOBBY FOURTH SCALE: TYPICAL ELEVATOR WIRING DIAGRAM 8 NOT TO SCALE NOTES: 1. PROVIDE ENGRAVED PHOENELIC NAMEPLATE ON DISCONNECTS STATING MORE THAN ONE SOURCE SERVES THE ELEVATOR CABINET. 2. SHOULD THE GENERAL CONTRACTOR UTILIZE AN ELEVATOR MANUFACTURER THAT REQUIRE MORE ELECTRICAL WORK THAN SHOWN ON THIS DETAIL, THE COSTS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 3. IF ELEVATOR CAN BE OPERATED FROM NEC 702 OPTIONAL POWER SYSTEM, ALL HVAC EQUIPMENT SERVING THE ELEVATOR EQUIPMENT ROOM SHALL BE CONNECTED TO THE OPTIONAL POWER SYSTEM. 4. EQUIPMENT SHOWN SHADED IS BY ELEVATOR MANUFACTURER. ITEMS SHOWN DARK ARE BY DIVISION 26. TO 208/120V PANEL DEDICATED CIRCUIT TO 208/120V PANEL DEDICATED CIRCUIT IN ELEVATOR RECEPTACLE GFI 2#12,#12G., 3/4"C. TO 208/120V PANEL DEDICATED CIRCUIT TO 480/277V PANEL DEDICATED CIRCUIT MACHINE ROOM LIGHT FIXTURES IN ROOM 2#14, 3/4"C. CB 480V 3P CIRCUIT BREAKER, PER ONE LINE DIAGRAM WITH AUXILIARY N.O. CONTACT IN ELEVATOR MACHINE ROOM 20A/1P CIRCUIT BREAKER IN ELEVATOR MACHINE ROOM 2#10, #10G., 3/4"C. TO 208/120V PANEL PER PLANS FLOOR LOBBY FIFTH DOOR POWER SUPPLYCONTROLLER ELECTRIC STRIKE READER ON UNSECURED SIDE 120V TO SYSTEM CONTROL WIRING AND CONNECTION IN DOOR FRAME MAGNETIC DOORCONTACTS NOTES: 1. DOOR HARDWARE AND POWER SUPPLY FURNISHED BY OTHER TRADE. 2. PROVIDE WIRING PER SYSTE MANUFACTURING INSTRUCTIONS. SCALE: TYPICAL SECURE DOOR DETAIL 6 NONE CU GRD. BAR RACKS #6 AWG INSULATED GROUND CONDUCTOR MDF & IDF'S MAIN EQUIPMENT BONDING G JUMPER (SIZE IN ACCORDANCE WITH NEC ARTICLE 250) TO MAIN SERVICE EQUIPMENT SWITCHBOARD OR PANELBOARD GROUND BUS AT SERVICE ENTRANCE N G PANELBOARD G DISTRIBUTION PANELBOARD N N G PANELBOARD EQUIPMENT GROUND - SIZE AS SHOWN ON DRAWINGS TRANSFORMER C N B A BONDING JUMPERS (SIZE IN ACCORDANCE WITH NEC ARTICLE 250) N G COMMUNICATIONS SYSTEMS EQUIPMENT CABINET GROUND COMMUNICATIONS PLYWOOD BACKBOARD GROUND BAR TELEPHONE SERVICE DEMARK GROUND BAR 3/4"X10' CU GROUND ROD AS REQUIRED (SEE SECTION 260526) #3/0 CU BONDING JUMPER IF NOT FACTORY INSTALLED EQUIPMENT GROUND. SIZE AS SHOWN ON DRAWINGS EQUIPMENT GROUND - SIZE AS SHOWN ON DRAWINGS G NEUTRAL BUS GROUND BUS BUILDING STEEL (INDOOR) OR GROUND ROD (OUTDOOR) GENERATOR FRAME AND ENCLOSURE N C GENERATOR B A #3/0 BARE CU GROUNDING ELECTRODE CONDUCTOR #3/0 CU EQUIPMENT BONDING JUMPER BONDING BUSHING (TYPICAL) SERVICE EQUIPMENT ENCLOSURE (MAIN SWITCHBOARD) MAIN BONDING JUMPER (SIZE IN ACCORDANCE WITH NEC ARTICLE 250) PANELBOARD AUTOMATIC TRANSFER SWITCH ENCLOSURE (SWITCHED NTL) NOT TO SCALE TYPICAL GROUNDING DETAIL BUILDING STEEL OR INTERIOR METAL WATER PIPE AND GROUND ROD IF STEEL IS NOT AVAILABLE #3/0 BARE CU GROUNDING ELECTRODE CONDUCTOR BUILDING FOUNDATION REBAR #3/0 BARE CU GROUND RING INCOMING METAL WATER SERVICE INCOMING SERVICE METAL CONDUITS TRANSFORMER ENCLOSURE #3/0 BARE CU GROUNDING ELECTRODE CONDUCTOR IG IG IG TRANSFORMER C N B A NTL AS SHOWN ON DRAWINGS NO GROUND CABLE TO NTL UTILITY TRANSFORMER TO UTILITY TRANSFORMER ISOLATED GROUND- SIZE AS SHOWN ON DRAWINGS WHEN REQUIRED 3/4"X10' CU GROUND ROD (TYP.) BUILDING STEEL (TYP.) 9 CONC. SLAB PER PLANS FINISHED FLOOR STEEL COLUMN PER PLANS CL 3/4" x 10'-0" COPPER CLAD STEEL GROUND ROD FOOTINGS PER PLANS BONDING PLATE OR EXOTHERMIC WELD TO STEEL COLUMN EXOTHERMIC CONNECTION TO GROUND ROD CLASS II COPER GROUNDING CONDUCTOR 1" PVC CONDUIT SLEEVE SCALE: COLUMN GROUNDING DETAIL 10 NONE 05/01/18 Nick Mishler