HomeMy WebLinkAboutP-000-PLUMBING-SYMBOLS-&-ABBREVIATIONS-Rev.2SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CLIENT ARCHITECT 17105 NOVEMBER 15, 2017 CONSTRUCTION SET MERCHANTS CORPORATE CENTER CARMEL, IN P-000 PLUMBING SYMBOLS & ABBREVIATIONS PIPING IDENTITY SYMBOLS FLOW DIRECTION ARROW, PITCH DIRECTION ARROW PIPE RISE PIPE DROP PIPE CAP PIPE CONTINUES (REFERENCE ELSEWHERE) PIPE GUIDE PIPE ANCHOR FLEXIBLE CONNECTOR EXPANSION COMPENSATOR EXPANSION LOOP CONCENTRIC, ECCENTRIC FITTINGS UNION, FLANGED UNION GATE VALVE BALL VALVE GLOBE VALVE BUTTERFLY VALVE PLUG VALVE CHECK VALVE PRESSURE REDUCING VALVE REDUCED PRESSURE BACKFLOW PREVENTER DOUBLE CHECK BACKFLOW PREVENTER DOUBLE DETECTOR CHECK VALVE ASSEMBLY ANGLE VALVE RELIEF VALVE VALVE WITH OUTSIDE STEM & YOKE PNEUMATIC TWO-WAY CONTROL VALVE PNEUMATIC THREE-WAY CONTROL VALVE ELECTRIC TWO-WAY CONTROL VALVE ELECTRIC THREE-WAY CONTROL VALVE SOLENOID VALVE FLOW SWITCH PRESSURE SWITCH AQUASTAT ORIFICE FLOW METER VENTURI FLOW METER TURBINE FLOW METER CALIBRATED BALANCE VALVE AUTOMATIC FLOW CONTROL VALVE STRAINER STRAINER WITH CAPPED BLOWDOWN MANUAL AIR VENT AUTOMATIC AIR VENT VACUUM BREAKER TEMPERATURE/PRESSURE TAP THERMOMETER PRESSURE GAUGE STEAM TRAP WITH DESIGNATION REFRIGERATION SIGHT GLASS AIR FILTER/DRYER REFRIGERATION THERMAL EXPANSION VALVE INLINE PUMP DIFFERENTIAL PRESSURE TRANSMITTER WATER HAMMER ARRESTER WITH SCHEDULE TYPE P-TRAP AND RISER FLOOR DRAIN WITH SIZE & SCHEDULE TYPE END OF PIPE CLEANOUT FLOOR CLEANOUT WALL CLEANOUT EXTERIOR CLEANOUT OR RODDING HOLE THERMOSTATIC MIXING VALVE WITH SCHEDULE TYPE HOSE BIBB, WALL HYDRANT WITH SCHEDULE TYPE WATER METER GAS METER ROOF DRAIN, OVERFLOW DRAIN WITH SIZE POST INDICATOR VALVE FIRE DEPARTMENT CONNECTION VALVE TAMPER SWITCH UPRIGHT SPRINKLER HEAD PENDANT SPRINKLER HEAD DRY PENDANT SPRINKLER HEAD CONCEALED SPRINKLER HEAD SIDEWALL SPRINKLER HEAD F T P S M M CO 4"RD 4"OFD X X X REFERENCE SYMBOLS SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA FOR ADDITIONAL INFORMATION. KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. DRAWING BLOCK TITLE INDICATOR: REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL INFORMATION. MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. EQUIPMENT INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. DIFFUSER, GRILLE, REGISTER INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. TU-XL.## X X X X X PIPING LINE SYMBOLS HIGH PRESSURE STEAM (>61 PSIG) STORM DRAIN MEDIUM PRESSURE STEAM (16-60 PSIG) FOOTING/FOUNDATION DRAIN LOW PRESSURE STEAM (<15 PSIG) SANITARY WASTE (W) HIGH PRESSURE CONDENSATE SANITARY GREASE MEDIUM PRESSURE CONDENSATE SANITARY FORCED MAIN LOW PRESSURE CONDENSATE SANITARY VENT (V) BOILER BLOW DOWN ACID WASTE BOILER FEED ACID VENT PUMPED CONDENSATE DRAIN VACUUM PUMP DISCHARGE INDIRECT WASTE HUMIDIFICATION PUMP DISCHARGE MAKE UP WATER DOMESTIC COLD WATER (CW) AIR RELIEF VENT DOMESTIC HOT WATER SUPPLY (HW) HEAT RECLAIM PIPING DOMESTIC HOT WATER RETURN (HWR) HEATING WATER SUPPLY 140°F HOT WATER HEATING WATER RETURN 140°F HOT WATER RETURN REFRIGERANT DISCHARGE NON-POTABLE WATER REFRIGERANT SUCTION DRINKING WATER SUPPLY REFRIGERANT LIQUID DRINKING WATER RETURN REFRIGERANT HOT GAS SOFT WATER BRINE SUPPLY CHLORINATED WATER BRINE RETURN DISTILLED WATER CONDENSER WATER SUPPLY DEIONIZED WATER CONDENSER WATER RETURN FIRE SUPPRESSION CHILLED WATER SUPPLY NATURAL GAS (WC OR PSIG) CHILLED WATER RETURN GAS VENT DUAL TEMPERATURE SUPPLY LIQUID PETROLEUM DUAL TEMPERATURE RETURN MEDICAL COMPRESSED AIR (WC OR PSIG) HEAT PUMP WATER SUPPLY MEDICAL VACUUM HEAT PUMP WATER RETURN OXYGEN GLYCOL HEATING SUPPLY NITROGEN GLYCOL HEATING RETURN NITROUS OXIDE FUEL OIL SUPPLY CARBON DIOXIDE FUEL OIL RETURN WET VACUUM CLEANING FUEL OIL VENT DRY VACUUM CLEANING CONDENSATE DRAIN COMPRESSED AIR (WC OR PSIG) CONTROL WIRING TEMPERED WATER SUPPLY TEMPERED WATER RETURN LINETYPE DESIGNATORS THIN CONTINUOUS LINETYPE INDICATE EXISTING ITEMS TO REMAIN. INTERMEDIATE DASHED LINETYPE INDICATE EXISTING ITEMS TO BE REMOVED. INTERMEDIATE OR WIDE CONTINUOUS LINETYPE INDICATE NEW ITEMS. THIN HALFTONE LINETYPE INDICATE ITEMS BY OTHER DISCIPLINE. INDICATES POINT OF NEW CONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. INDICATES POINT OF DISCONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. SHEET TYPE DESIGNATORS 000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES) 100 PLANS 200 ELEVATIONS 300 SECTIONS 400 LARGE SCALE VIEWS (PLANS, ELEVATIONS OR SECTIONS) 500 DETAILS 600 SCHEDULES OR DIAGRAMS 700 (USER DEFINED) 800 (USER DEFINED) 900 3D REPRESENTATIONS (ISOMETRICS) NOTATION DESIGNATORS GENERAL NOTES: NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES WITHIN THE DRAWING SET. GENERAL MECHANICAL NOTES: NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN THE DISCIPLINE. GENERAL SHEET NOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR. SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR TO IDENTIFY ITEMS. HR DTR BF DVC WVC N0 N 0 MV MA GV LP G F DE DI CL SW DWR DWS 140°F 140°F PD D AV AW FD ST DTS FOV FOR FOS GHR GHS RHG CD HPWR HPWS RL H CWR CWS CR CS BR BS RS RD HHR HHS ARV MU VPD PC BBD LPC MPC HPC LPS MPS HPS FM SG ABBREVIATIONS AND TERMS Ø DIAMETER, PHASE ET EXPANSION TANK OAT OUTSIDE AIR TEMPERATURE (°F) °F DEGREES FAHRENHEIT EW EMERGENCY EYEWASH OBD OPPOSED BLADE DAMPER A/C AIR CONDITIONING EWC ELECTRIC WATER COOLER OD OUTSIDE DIAMETER, OVERFLOW DRAIN ACC AIR COOLED CONDENSER EWT ENTERING WATER TEMPERATURE (°F) OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED ACCU AIR COOLED CONDENSING UNIT EXH EXHAUST OSD OPEN SITE DRAIN AD AREA DRAIN, ACCESS DOOR EXIST EXISTING OZ OUNCE AFF ABOVE FINISHED FLOOR F FURNACE P PUMP AFMS AIR FLOW MEASURING STATION F&T FLOAT AND THERMOSTATIC STEAM TRAP PBD PARALLEL BLADE DAMPER AGA AMERICAN GAS ASSOCIATION FCO FLOOR CLEANOUT PC PLUMBING CONTRACTOR AHU AIR HANDLING UNIT FCU FAN COIL UNIT PD PRESSURE DROP AL ACOUSTICALLY LINED, ALUMINUM FD FLOOR DRAIN, FIRE DAMPER PE PNEUMATIC ELECTRIC AMB AMBIENT FDC FIRE DEPARTMENT CONNECTION PH PHASE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE FDTN FOUNDATION PIV POST INDICATOR VALVE AO ANALOG OUTPUT FE FIRE EXTINGUISHER PPM PARTS PER MILLION AP ACID PROOF, ACCESS PANEL FHC FIRE HOSE CABINET PRV PRESSURE REDUCING VALVE APD AIR PRESSURE DROP (IN. WC.) FLR FLOOR PSI POUNDS PER SQUARE INCH ARCH ARCHITECT FM FACTORY MUTUAL PSIA POUNDS PER SQUARE INCH ABSOLUTE ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE FOV FUEL OIL VENT PSIG POUNDS PER SQUARE INCH GAUGE ARV AIR RELIEF VALVE FPM FEET PER MINUTE PTAC PACKAGED TERMINAL AIR CONDITIONER AS AIR SEPARATOR FPVAV FAN POWERED VAV UNIT PVC POLYVINYL CHLORIDE ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING FS FLOOR SINK R REGISTER AND AIR CONDITIONING ENGINEERS FSC FIRE SUPPRESSION CONTRACTOR R12 REFRIGERANT (12, 22, ETC.) ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS FSD COMBINATION FIRE/SMOKE DAMPER RA RETURN AIR ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS FT FOOT, FEET RADN RADIATION ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS FTG FOOTING RAT RETURN AIR TEMPERATURE (°F) ATM ATMOSPHERE FTR FINNED TUBE RADIATION RCP REINFORCED CONCRETE PIPE AUTO AUTOMATIC G NATURAL GAS RD ROOF DRAIN AVG AVERAGE GA GAGE OR GAUGE REV REVOLUTIONS AVS ACID VENT STACK GAL GALLON RF RETURN FAN AW ACID WASTE GC GENERAL CONTRACTOR RG RETURN GRILLE AWWA AMERICAN WATER WORKS ASSOCIATION GIV GRAVITY INTAKE VENTILATOR RH RELATIVE HUMIDITY, RODDING HOLE BD BUTTERFLY DAMPER GPD GALLONS PER DAY RM ROOM BDD BACKDRAFT DAMPER GPH GALLONS PER HOUR RP RADIANT PANEL BE BOTTOM ELEVATION GPM GALLONS PER MINUTE RPM REVOLUTIONS PER MINUTE BF BARRIER FREE GR GRILLE, GRAINS RPS REVOLUTIONS PER SECOND BFC BELOW FINISHED CEILING GRV GRAVITY RELIEF VENTILATOR RTU ROOF TOP UNIT BHP BRAKE HORSEPOWER GT GREASE TRAP RV RELIEF VALVE, ROOF VENT BLDG BUILDING HB HOSE BIBB SA SUPPLY AIR BOD BOTTOM OF DUCT HD HEAD (FT.) SAN SANITARY BOP BOTTOM OF PIPING Hg MERCURY SD SUPPLY DIFFUSER, SMOKE DAMPER BSMT BASEMENT HHWP HEATING HOT WATER PUMP SEER SEASONAL ENERGY EFFICIENCY RATIO BT BATHTUB HO HUB OUTLET SF SQUARE FOOT, SUPPLY FAN, SAFETY FACTOR BTM BOTTOM HORIZ HORIZONTAL SG SUPPLY GRILLE BtuH BRITISH THERMAL UNIT PER HOUR HP HORSEPOWER, HEAT PUMP SU SHOWER UNIT CA COMPRESSED AIR HR HOUR(S) SK SINK CAV CONSTANT AIR VOLUME HRTU HEATING ONLY ROOFTOP UNIT SMACNA SHEET METAL AND AIR CONDITIONING CB CATCH BASIN HX HEAT EXCHANGER CONTRACTORS NATIONAL ASSOCIATION CCW COUNTERCLOCKWISE Hz HERTZ SP STATIC PRESSURE CD CONDENSATE DRAIN IB INVERTED BUCKET STEAM TRAP SPEC SPECIFICATION CO₂ CARBON DIOXIDE ID INSIDE DIAMETER SQ SQUARE CF CEILING FAN IE INVERT ELEVATION SR SUPPLY REGISTER CFM CUBIC FEET PER MINUTE IN INCH, INCHES SRV SAFETY RELIEF VALVE CH CHILLER INT INTERIOR SS SERVICE SINK, STAINLESS STEEL CHWP CHILLED WATER PUMP INV INVERT STD STANDARD CI CAST IRON IPS INTERNATIONAL PIPE STANDARD SV STEAM VENT CMP CORRUGATED METAL PIPE IW INDIRECT WASTE TCC TEMPERATURE CONTROL CONTRACTOR CO CLEANOUT K KELVIN TCP TEMPERATURE CONTROL PANEL COMPR COMPRESSOR KEC KITCHEN EQUIPMENT CONTRACTOR TD TEMPERATURE DIFFERENCE COND CONDENSER kW KILOWATT TE TOP ELEVATION CONV CONVECTOR LAB LABORATORY TEMP TEMPERATURE CP CONDENSATE PUMP LAT LEAVING AIR TEMPERATURE (°F) TF TRANSFER FAN CPVC CHLORINATED POLYVINYL CHLORIDE L LAVATORY TG TRANSFER GRILLE CT COOLING TOWER LBS POUNDS TMV THERMOSTATIC MIXING VALVE CU CONDENSING UNIT LD LINEAR DIFFUSER TONS TONS OF REFRIGERATION CUH CABINET UNIT HEATER LP LIQUID PETROLEUM TP TRAP PRIMER CUV CLASSROOM UNIT VENTILATOR LTG LIGHTING TRANS TRANSITION CV CONTROL VALVE LWT LEAVING WATER TEMPERATURE (°F) TS TAMPER SWITCH CW CLOCKWISE MA MIXED AIR TSP TOTAL STATIC PRESSURE (IN. WC.) CWP CONDENSER WATER PUMP MAT MIXED AIR TEMPERATURE (°F) TXV THERMAL EXPANSION VALVE dB DECIBEL MAX MAXIMUM TYP TYPICAL DB DRY BULB MB MOP BASIN UCD UNDERCUT DOOR DF DRINKING FOUNTAIN MBH THOUSAND Btu PER HOUR UH UNIT HEATER DG DOOR GRILLE MC MECHANICAL CONTRACTOR UL UNDERWRITERS LABORATORIES DH DUCT HEATER MCA MINIMUM CIRCUIT AMPS UON UNLESS OTHERWISE NOTED DI DIGITAL INPUT MCC MOTOR CONTROL CENTER UR URINAL DIA DIAMETER MD MOTORIZED DAMPER US UP STREAM DIFF DIFFUSER MFR MANUFACTURER UV UNIT VENTILATOR DN DOWN MH MANHOLE V VOLTS, VENT DO DIGITAL OUTPUT MIN MINIMUM VAC VACUUM DS DOWNSPOUT, DOWN STREAM MISC MISCELLANEOUS VAV VARIABLE AIR VOLUME DW DISTILLED WATER MS MOP SINK VB VACUUM BREAKER DWG DRAWING MTD MOUNTED VD VOLUME DAMPER DWH DOMESTIC WATER HEATER MV MANUAL VENT VEL VELOCITY DWV DRAIN, WASTE & VENT N NITROGEN VERT VERTICAL DX DIRECT EXPANSION NA NOT APPLICABLE VF VENTILATION FAN EA EXHAUST AIR NC NOISE CRITERIA, NORMALLY CLOSED VFD VARIABLE FREQUENCY DRIVE EAT ENTERING AIR TEMPERATURE (°F) NEC NATIONAL ELECTRIC CODE VTR VENT THROUGH ROOF EC ELECTRICAL CONTRACTOR NFC NATIONAL FIRE CODE VUV VERTICAL UNIT VENTILATOR ECO EXTERIOR CLEANOUT NFPA NATIONAL FIRE PROTECTION ASSOCIATION W WASTE, WATT EDR EQUIVALENT DIRECT RADIATION NFWH NON-FREEZE WALL HYDRANT WC WATER COLUMN EER ENERGY EFFICIENCY RATIO NIC NOT IN CONTRACT WB WET BULB EF EXHAUST FAN NO NORMALLY OPEN, NITROUS OXIDE WC WATER CLOSET EFF EFFICIENCY NOM NOMINAL WCO WALL CLEANOUT EG EXHAUST GRILLE NPW NON-POTABLE WATER WH WALL HYDRANT EL ELEVATION NTS NOT TO SCALE WPD WATER PRESSURE DROP (FT. HD.) EOM END OF MAIN DRIP O OXYGEN WSHP WATER SOURCE HEAT PUMP ES EMERGENCY SHOWER OA OUTSIDE AIR YD YARD DRAIN ESP EXTERNAL STATIC PRESSURE (IN. WG.) OAI OUTSIDE AIR INTAKE SECTION LOCATION IN DRAWING MODULE SECTION LOCATION AT SUBSET SHEET DETAIL LOCATION IN DRAWING MODULE DETAIL LOCATION AT SUBSET SHEET LARGE SCALE VIEW LOCATION IN DRAWING MODULE LARGE SCALE VIEW LOCATION AT SUBSET SHEET KEYNOTE INDICATORS SCHEDULE TYPE EQUIPMENT TYPE AIRFLOW (CUBIC FEET PER MINUTE) NUMERIC CHARACTER RELATES TO ITEM ALPHANUMERIC CHARACTER RELATES TO ASSOCIATED AIR HANDLER (OPTIONAL) AREA LEADER LINE LEADER POINT LEADER DRAWING MODULE LOCATION (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) REVISION CLOUD REVISION INDICATOR NUMERIC SCALE GRAPHIC SCALE IW A TWS TWR SEE XXX REFER TO ADDITIONAL SHEET FOR CONTINUATION FLOOR PLAN OVERLAP BEYOND AREA EXTENSION DISCIPLINE DESIGNATORS F-000 FIRE SUPPRESSION P-000 PLUMBING PD000 PLUMBING DEMOLITION PG000 PLUMBING GAS PS000 PLUMBING SANITARY PW000 PLUMBING WATER M-000 MECHANICAL MD000 MECHANICAL DEMOLITION MH000 MECHANICAL HVAC MP000 MECHANICAL PIPING PLAN PLAN GENERAL PLUMBING NOTES A. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. THE SAME ARE MADE A PART OF THESE CONTRACT DOCUMENTS AS IF REPEATED HEREIN. B. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS NOT BORNE BY THE UTILITY COMPANIES (OR DEPARTMENTS). C. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. D. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. E. THE ENGINEERING DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE ARCHITECTURAL DRAWINGS IN DEFINING THE WORK OF THE CONTRACT DOCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF ENGINEERING WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE ENGINEERING DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION, THE DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. F. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCING THE WORK. EXPLICIT DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. G. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BIDDING OR BEGINNING WORK ON THIS PROJECT. H. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. I. ANY DETAILS, SYSTEMS AND/OR MATERIALS WHICH ARE PROPOSED TO BE CHANGED MUST FIRST BE REVIEWED BY THE OWNER AND ARCHITECT/ENGINEER PRIOR TO THE PREPARATION OF SHOP DRAWINGS. J. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND TEMPLATE DRAWINGS FOR ALL MECHANICAL EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATORS, SPRING ISOLATION, ETC., NOT SHOWN ON THE DRAWINGS. K. SPECIFIC MODEL NUMBERS LISTED ON DRAWINGS AND IN SPECIFICATIONS ARE BASIS OF DESIGN AND ARE LISTED FOR REFERENCE PURPOSES. OTHER MANUFACTURERS AND MODELS MAY BE ACCEPTABLE AS SET FORTH IN THE SPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ADDITIONAL WORK RESULTING FROM INSTALLATION OF EQUIPMENT NOT LISTED AS BASIS OF DESIGN. L. ALL EQUIPMENT SHALL BE COMPLETELY INSTALLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE IN WORKING CONDITION PRIOR TO ACCEPTANCE BY THE OWNER. START-UP SHALL BE PERFORMED BY FACTORY AUTHORIZED REPRESENTATIVE. M. COORDINATE ALL FLOOR OPENINGS, EXACT LOCATION AND SIZE OF ALL WALL, CEILING OR ROOF PENETRATIONS REQUIRED FOR PIPING WITH G.C. AND OTHER TRADES. N. EACH BRANCH LINE SERVING EQUIPMENT (OR FIXTURES WITHIN ROOM OR BACK TO BACK TOILET ROOMS), SHALL BE VALVED INDEPENDENTLY OF OTHER FIXTURES REGARDLESS OF TYPE OF VALVES SHOWN (WHEN INDICATED.) O. PROVIDE ISOLATION VALVES AS DESCRIBED ABOVE AT EACH PIECE OF EQUIPMENT. P. PROVIDE P.D.I. RATED (AND SIZED) BELLOWS TYPE WATER HAMMER ARRESTORS ON ALL HOT AND COLD WATER BRANCH LINES SERVING FIXTURES AND EQUIPMENT. SEE DETAILS FOR ACCEPTABLE LOCATIONS, OTHER LOCATIONS MAY BE SHOWN ON PLANS Q. RUN FULL SIZE HOT AND COLD PIPE HEADER FULL LENGTH OF CHASE (UNLESS NOTED OTHERWISE) AND PROVIDE WATER HAMMER ARRESTORS AND APPROPRIATE ACCESS DOOR AND FRAME (WHEN REQUIRED). NUMERIC CHARACTER RELATES TO ITEM NORTH ARROW BEYOND AREA EXTENSION X X X X X MULTIPLIER ALPHANUMERIC CHARACTER RELATES (OPTIONAL) TO BUILDING LEVEL (OPTIONAL) F&T T M DPT CO₂ NPW FD HB-1 WH-1 FCO 2"FD-1 WCO ECO TMV-1 WHA-A N SCALE: 0 4' 8' 16' DRAWING TITLE X 1/8" = 1'-0" NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECT NOTE: A. ALL AREAS OF THE BUILDING SHALL BE PROTECTED BY AN AUTOMATIC WET / DRY SPRINKLER SYSTEM (S). GENERAL FIRE PROTECTION NOTES B. SPRINKLER SYSTEMS SHALL COMPLY WITH ALL AUTHORITIES HAVING JURISDICTION (INCLUDING, BUT NOT LIMITED TO) INDIANA BUILDING CODE, INDICNA PLUMBING CODE, NFPA STANDARDS 13. 13 R, 20 & 24, LOCAL FIRE DEPARTMENT. C. INTENT OF THESE DOCUMENTS ARE TO PROVIDE THE SPRINKLER CONTRACTOR A BASIS OF DESIGN AND TO ASSIST IN COORDINATION OF THE SYSTEM WITH OTHER TRADES. IT IS NOT THE INTENT OF THSES DOCUMENTS TO ALTER OF SUPERCEDE APPLICABLE CODES OR STANDARDS. D. THE SPRINKLER FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR THE DESIGN, LAYOUT AND THE HYDRAULIC CALCULATIONS OF THE PROPOSED SPRINKLER SYSTEM(S) AS REQUIRED TO MEET CODE REQUIREMENTS. E. INSTALL INSPECTORS TEST CONNECTIONS WITH 1-1/4" TEST DROP, BALL VALVE AND SIGHT GLASS. TERMINATE TEST PIPING OVER NEAREST FLOOR DRAIN OR THRU EXTERIOR WALL WHENEVER POSSIBLE F. SPRINKLERS: 1. AREAS THAT HAVE CEILINGS SHALL HAVE CONCEALED SPRINKLERS INSTALLED. 2. AREAS WITHOUT CEILINGS SHALL HAVE UPRIGHT, EXPOSED TYPE SPRINKLER S INSTALLED. 3. SPRINKLERS INSTALLED IN A GARAGE AREA SHALL HAVE WIRE GUARD. 4. SPRINKLER MANUFACTURERS: TYCO, VIKING. G. ALL AREAS THAT ARE SUBJECT TO FREEZING CONDITIONS SHALL BE PROTECTED WITH A DRY-PIPE SPRINKLER SYSTEM. H. CONTRACTOR SHALL BE RESPONSIBLE FOR CONDUCTING HIS OWN FLOW TEST, UPON WHICH HIS DESIGN IS TO BE BASED. A MINIMUM OF 10% DEGRADATION OF SYSTEM PRESSURE SHALL BE ASSUMED FOR SUMMER MONTHS. THE ENTIRE SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED. I. HYDRAULIC PLACARDS TO BE MOUNTED ON EACH ZONE RISER. J. THE FIRE DEPARTMENT CONNECTION (FDC) SHALL BE LOCATED ON EXTERIOR OF BUILDING. COORDINATE EXACT LOCATION WITH LOCAL FIRE DEPARTMENT AUTHORITY. K. POST INDICATOR VALVE (PIV) SHALL BE LOCATED WHERE SHOWN ON DRAWINGS, COORDINATE FINAL LOCATION WITH SITE/CIVIL CONTRACTOR. L. DRY-PIPE SYSTEM: AIR COMPRESSOR SHALL BE SIZED, FURNISHED AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR. 05/01/18 Nick Mishler