HomeMy WebLinkAboutP-601-PLUMBING-SCHEDULES-Rev.2SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT CLIENT ARCHITECT 17105 NOVEMBER 15, 2017 CONSTRUCTION SET MERCHANTS CORPORATE CENTER CARMEL, IN P-601 PLUMBING SCHEDULES MATERIAL OUTLET SIZE OUTLET TYPE MATERIAL SIZE TYPE NOTES: 1. PROVIDE DEEP SEAL P-TRAP. 2. PROVIDE AND INSTALL DRAIN WITH 'SURE-SEAL', 'TRAP-GAURD', 'QUAD-CLOSE', OR SIMILAR SEWER GAS BACKUP PROTECTION. 3. INTEGRAL P-TRAP. 4. PROVIDE WITH F-3750 FUNNEL / STRAINER MARK DESCRIPTION DRAIN BODY STRAINER INTEGRAL TRAP VANDAL PROOF SEDIMENT BUCKET FUNNEL INTEGRAL CLEANOUT MANUFACTURER WITH MODEL NUMBER NOTES FLOOR DRAIN SCHEDULE FD-1 FLOOR DRAIN CAST IRON AS NOTED NO HUB CAST IRON AS REQ'D YES YES NO NO NO NO J.R. SMITH #2005 1, 2 FD-2 FLOOR DRAIN CAST IRON AS NOTED NO HUB CAST IRON AS REQ'D NO NO NO NO NO J.R. SMITH #2005-F37 1, 2, VALVE SCHEDULE TYPE MANUFACTURER 2" AND SMALLER 2-1/2" AND LARGER MANUFACTURER WITH MODEL NUMBER GATE JENKINS MILWAUKEE STOCKHAM BALL JENKINS MILWAUKEE STOCKHAM BUTTERFLY JENKINS MILWAUKEE STOCKHAM CHECK JENKINS MILWAUKEE STOCKHAM THREADED/FLANGED PIPING 47-C 148 B-100 901A BA100 S-216-BR1-R-T - - - 4092 509 B-319 651-C 2885 G-623 - - - 2232-E ML-133-E LD-712-BS3-E 624-C F2974 G-931 1242-C 115 B-108 902A BA150 S-216-BR1-R-S - - - 4093 1509 B-309 NOTES 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 NOTES: 1. 2. VALVES MATERIAL (BODIES, DISC, GASKETS, LINING, PACKAGES, ECT.) SHALL BE APPROVED FOR THE SERVICE IN WHICH THEY ARE INSTALLED. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE INDICATED. 3. VALVES SHALL BE EQUIPPED WITH ACCESSORIES AS REQUIRED. NOTES: 1. USC APPROVED, FDA EPOXY COATED STRAINER, 7.5 FPS FLOW. 2. IN-LINE, INDEPENDENT CHECK VALVES WITH AN INTERMEDIATE RELIEF VALVE, NON-RISING STEM RESILIENT SEATED GATE VALVES. 3. PROVIDE UNIT WITH AIR GAP DRAIN ASSEMBLY, PIPE DRAIN TO NEAREST FLOOR DRAIN. 4. MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR. 5. LEAD FREE. MARK LOCATION SYSTEM TYPE DESIGN CAPACITY (GPM) PRESS. DROP (PSIG) SIZE (IN) MANUFACTURER WITH MODEL NUMBER NOTES BACKFLOW PREVENTER SCHEDULE BFP-1 WATER ENTRANCE ROOM MAIN CW SYSTEM REDUCED PRESSURE ZONE ASSEMBLY 210 12 3" WATTS LF909 1, 2, 3, 4, 5 BFP-2 WATER ENTRANCE ROOM MAIN CW SYSTEM REDUCED PRESSURE ZONE ASSEMBLY 210 12 3" WATTS LF909 1, 2, 3, 4, 5 DCVA-1 DOUBLE CHECK VALVE ASSEMBLY WATER ENTRANCE ROOM 1,000 6 8 " WATTS #LF709-S-6" FIRE PROTECTION SYSTEM 1, 2, 3, 4, 5 SUCT. (IN) DISCH (IN) HP RPM VOLTS PH NOTES 1. SKID MOUNTED PACKAGED DOMESTIC WATER PRESSURE BOOSTER SYSTEM. VARIABLE SPEED DRIVES, PROGRAMMABLE CONTROLS, SUCTION PRESSURE: 35 PSI. OVER ALL SYSTEM PRESSURE DISCHARGE BOOST PRESSURE OF OF 70 PSIG WITH A SUPPLY FLOW RATE OF 0 TO 420 GPM, VERTICALLY MOUNTED PUMPS, UNIT TO BE PROVIDED WITH A -" STAINLESS STEEL INLET AND DISCHARGE MANIFOLDS WITH WELDED OR 150 POUND FLANGE CONNECTIONS. UNIT DOES NOT REQUIRE TANK. CONTRACTOR TO BE PROVIDED WITH DIAPHRAGM TANK IF SUBMITTED PACKAGE DIFFERS FROM MARK LOCATION SYSTEM TYPE DESIGN CAPACITY (GPM) DESIGN CAPACITY (FT. HD) MIN EFF. PUMP MOTOR DATA MANUFACTURER WITH MODEL NUMBER NOTES PUMP SCHEDULE DWBP-1 WATER ENTRANCE DOMESTIC WATER DUPLEX DOMESTIC WATER BOOSTER PUMP PACKAGE 142 111 - - - 5.0 (EA) 3600 460 3 B&G: MODEL HVL-eHV SERIES 10 1,3,6 WATER HAMMER ARRESTOR SCHEDULE TYPE FIXTURE UNIT RATING I.P.S. J. R. SMITH NUMBER NOTES WHA-A 1-11 3/4" 5005 1 WHA-B 12-32 1" 5010 1 WHA-C 33-60 1" 5020 1 WHA-D 61-113 1" 5030 1 WHA-E 114-154 1" 5040 1 WHA-F 155-330 1" 5050 1 NOTES: 1. WATER HAMMER ARRESTORS SHALL BE SIZED AND INSTALLED PER THE PLUMBING DRAINAGE INSTITUTE (STANDARD PDI-WH 201) REQUIREMENTS IN ACCESSIBLE LOCATIONS ON THE COLD WATER AND HOT WATER PIPING WHERE FLUSH VALVES AND ANY OTHER QUICK CLOSING VALVES ARE USED. ROOF/OVERFLOW DRAIN SCHEDULE MARK DESCRIPTION DRAIN BODY STRAINER MANUFACTURER WITH MODEL NUMBER NOTES MATERIAL OUTLET SIZE OUTLET TYPE MATERIAL SIZE TYPE RD-1 ROOF DRAIN CAST IRON 6" NO-HUB CAST IRON CAST IRON J.R. SMITH #1010-E-R-C OFD-1 OVERFLOW ROOF DRAIN CAST IRON 6" NO-HUB CAST IRON CAST IRON J.R. SMITH #1080-E-R-C 2" WATER DAM NOTES: 1. PROVIDE UNDERDECK CLAMP AND SUMP RECEIVER, NICKEL BRONZE TOP FOR USE WITH LOOSE SET PAVERS. PIPING INSULATION SCHEDULE (INDOOR) SYSTEM FLUID TEMP. RANGE (ºF) INSULATION TYPE JACKET TYPE VAPOR BARRIER REQUIRED RUNOUTS (*NOTE 2) 1" & LESS 1.25" TO 2" 1.25" & GREATER INSULATION THICKNESS DOMESTIC HOT WATER & RETURN 100-130 MF OR FE FP - 0.5 0.5 0.5 1.0 DOMESTIC COLD WATER 40-75 MF OR FE FP - - 0.5 0.5 0.75 HORIZONTAL STORM WATER (*NOTE 3) 40-75 MF OR FE FP - - - 1.0 1.0 CONDENSATE DRAIN 40-55 MF OR FE FP - (*NOTE 1) 0.5 0.5 0.5 NOTES: 1. 2. RUNOUTS NOT EXCEEDING 12'-0" IN LENGTH 2" PIPE TO INDIVIDUAL HVAC TERMINAL UNITS. REFER TO MECHANICAL SHEETS. RUNOUTS THAT ARE NOT LARGER THAN 1" AND NON-CIRCULATING TO INDIVIDUAL PLUMBING UNITS. 3. INCLUDING EXISTING PIPING. FIELD VERIFY EXISTING SIZES AND LENGTHS. ABBREVIATIONS INSULATION TYPES JACKET TYPES FE FLEXIBLE ELASTOMETRIC FP FOIL & KRAFT MF MINERAL FIBER PAPER (FIBERGLASS) PVCPOLYVINYL CHLORIDE UNDERGROUND OVER HEAD SANITARY & VENT X X MATERIAL TYPE INSTALLATION LOCATION PIPING MATERIAL CAST IRON OR SCH 40 PVC SOLID WALL SYSTEM DOMESTIC WATER SOFT COPPER TYPE K X - X X HARD COPPER TYPE L X X PEX-a - NOTES HARD COPPER TYPE L X X - HARD COPPER TYPE L X X - FIRE PROTECTION SCH 40 BLACK STEEL - X 2 NOTES: 1. 2. 1. PIPING INSTALLED BELOW SLAB TO BE INSTALLED WITHIN A SCH 40 PVC PIPE SLEEVE. 2. THINWALL SPRINKLER PIPING WILL NOT BE PERMITTED ON THIS PROJECT. 1 1 - PLUMBING EQUIPMENT SCHEDULE MARK LOCATION MAKE AND MODEL NO. DESCRIPTION CAPACITY ELECTRICAL CHARACTERISTICS NOTES EWH-1 NOTES: 1. PROVIDE WITH AIR GAP FITTING. TERMINATE DRAIN LINE OVER FLOOR DRAIN. 2. PROVIDE WALL MOUNTING KIT 3. SET OUTLET TEMPERATURE AT 120° F. EWH-2 LOCHINVAR #HS-18-050 ELECTRIC WATER HEATER 18.0 KW TOTAL INPUT; 74.00 GPH RECOVERY AT 100ºF TEMPERATURE RISE; 50 GALLON CAPACITY 480 V, 3 PH, 60 HZ, CHRONOMITE #M-20L/277 ELECTRIC WATER HEATER 4.1 KW TOTAL INPUT; 0.35 GPH RECOVERY AT 100ºF TEMPERATURE RISE 277 V, 1 PH, 60 HZ, 1,6, 1, 2, 3,4,8, 4. MOUNT UNDERNEATH LAVATORY AS HIGH AS POSSIBLE WHILE STILL ALLOWING CLEARANCE FOR SERVICING. PROVIDE ONE EXTRA HEATING ELEMENT WITH EACH UNIT. PLUMBING FIXTURE ROUGH-IN SCHEDULE MARK FIXTURE TYPE ROUGH-IN SIZES FIXTURE MOUNTING HEIGHT WASTE NOTES SIZE VENT SIZE CW SIZE HW SIZE WC-1 WATER CLOSET 3" 2" 1" - FLOOR 15" RIM 1, 3 NOTES: 1. INSTALL ADA PLUMBING FIXTURES PER ANSI 117.1 GUIDELINES. 2. PROVIDE ADA OFFSET GRID STRAINER WITH PADDED SUPPLIES AND DRAIN. MANUFACTURER AMERICAN MODEL # FINISH WHITE TRAP INTEGRAL STOP VALVE SUPPLY FITTING REMARKS 3. TRAPS, SUPPLIES, ETC. TO BE CHROME. McGUIRE LF2165LK WC-2 WATER CLOSET -ADA - FLOOR 17" RIM 8, WHITE INTEGRAL INTEGRAL 3" 2" 1" L-1 LAVATORY WHITE McGUIRE B8902-C SLOAN FAUCET # ETF-80-4-PBDT McGUIRE LF2165LK 1 1/2" 1 1/2" 1/2" 1/2" COUNTERTOP MOUNTED - UR-1 URINAL WHITE 2" 1 1/2" 3/4" - WALL HUNG - - - SH1 SHOWER - ADA 1 1/2" 1 1/2" 1/2" 1/2" WD-1 FOOD WASTE DISPOSER BADGER 1/3 HP - 1 1/2" UNDER SINK MOUNTED 120V, 1 PH, 60 HZ, 1/3HP WMDP-1 CLOTHES WASHING MACHINE DRAIN PAN - - - FLOODSAVER WMBD32 - FLOOR MOUNTED - - - - - 32" x 27 1/2" x 3 1/2" DEEP I.D. IB-1 ICE MAKER SUPPLY BOX OATEY #38680 WHITE - - - - 1/2" - REFER TO DETAIL - PROVIDE INTEGRAL WATER HAMMER ARRESTER, CHROME PLATED 1/4 TURN BALL VALVE. PROVIDE FIRE RATED MODEL WHEN REQUIRED. HB-1 HOSE BIB - 3/4" - J.R. SMITH 5673-BFP ROUGH BRONZE 18" A.F.F. - - - WH-1 NON-FREEZE HOSE BIB J.R. SMITH 5619-PB-H POLISHED BRONZE - - 3/4" 24" A.F.G. - 4. BRUSHED NICKEL FINISH. - - SK-1 SINK ELKAY ELUHAD131650 STAINLESS 1 1/2" 1 1/2" 1/2" 1/2" - McGUIRE B8902-C McGUIRE LF2165LK - SK-2 SINK ELKAY STAINLESS 1 1/2" 1 1/2" 1/2" 1/2" McGUIRE B8902-C McGUIRE LF2165LK - - - - - - 6, - FP-1 WATER ENTRANCE FIRE FIRE BOOSTER PUMP PACKAGE 750 100 - - - 60 3600 460 3 AC AC8100 6x6x9F CAST IRON AS NOTED NO HUB CAST IRON AS REQ'D NO NO NO YES NO J.R. SMITH #2041 1, 2, 3, 4 STANDARD AMERICAN STANDARD AMERICAN STANDARD AMERICAN STANDARD FLOOR MOUNTED FIXTURE: FLOOR MOUNTED FIXTURE: UR-1 URINAL -ADA AMERICAN STANDARD 2" 1 1/2" 3/4" - WALL HUNG FD-3 FLOOR DRAIN NO NO AD-1 AREA DRAIN CAST IRON AS NOTED NO HUB CAST IRON AS REQ'D NO NO NO NO NO NO J.R. SMITH # 2614-y04 P-1 3RD. FLR. JAN. CLOSET DOMESTIC WATER RETURN EWH-3 LOCHINVAR JTCO-20FS ELECTRIC WATER HEATER SINGLE 2500 WATT ELEMENT TOTAL INPUT; 11 GPH RECOVERY AT 90ºF TEMPERATURE RISE 120 V, 1 PH, 60 HZ, 1,2 WASHBROOK 6501.001.020 WHITE MADERA 2624.001.020 MADERA 3249.001.020 SLOAN:COVER 140-1.6 WB-ES-S BEMIS #1655CT; WHITE ELONGATED PLASTIC SEAT,OPEN FRONT LESS SLOAN: 140-1.6 WB-ES-S COUNTERTOP MOUNTED SINGLE COMPARTMENT: FAUCET ELKAY # LK2477-CR BAR DECK WITH LEVER HANDLES COUNTERTOP MOUNTED DOUBLE COMPARTMENT: FAUCET ELKAY # LK100-CR, WITH SIDE SPRAY EWC-1 ELECTRIC WATER COOLER OASIS PF8ACSL 1 1/2" 1 1/2" 3/4" WALL MOUNTED-DUALHEIGHT DUAL-UNITS RH-1 ROOF HYDRANT WOODFORD SRH-MS 3/4" MOUNT AND SECURE TO ROOF FREEZLESS TYPE - NO DRAIN-LINE REQUIRED 5. FIBERGLASS TANKS WITH FLECK CONTROL HEAD AND ELECTRIC FLOW METER. ELUH3116 WITH POWERS MIXING VALVE # LF-496 WITH LAWLER MIXING VALVE # 801 6. THERMOSTATIC MIXING VALVE, LAWLER UNIT 25 gpm @ 10.0 PSI PRESSURE DROP IN-LINE 5.0 20' TDH 1" 1" 92 BELL & GOSSETT NBF-45 / 2-SPEED 2,5 2. PUMP SHALL BE CONTROLLED BY TIMER: B&G # TC-1 ET-1 AMTROL ST-5C ET-2 EXPANSION TANK BFP-1 BACKFLOW PREVENTOR FIRE SERVICE BACKFLOW PREVENTOR DOMESTIC WATER SERVICE EXPANSION TANK 3. EACH PUMP IS RATED 5.0 hp @ 71.0 gpm 4 4. MANUFACTURERS: AURORA -FAIRBANKS 5. MANUFACTURERS: B&G, GRUNDFOS, ROOMS: # 103, 104, 203, 204 AND 1ST. FLR BREAK RM. RM. # 308 RMS. # 108 & 208 WATER/ELECT. RMS. # 111 WATER/ELECT. RMS. # 111 RM. # 308 RM. # 308 AMTROL ST-12C TANK VOLUME= 2.0 MAX. ACCEPT. FACTOR= .45 TANK VOLUME= 6.4 MAX. ACCEPT. FACTOR= .50 WATTS MODEL LF909 SIZE: 4" WATTS MODEL 709DCDA SIZE: 6" 2940 1200 1 WATTS - BFP-2 DWS-1 AQUA SYSTEMS MODEL # 2900 WATER/ELECT. DOMESTIC WATER SOFTENER RMS. # 111 50.0 GPM @ 15 PSI DROP 125,000 GRAIN @ 10.0 LBS/CU/FT 120 V, 1 PH, 60 HZ, CONNECT TO GFI OUTLET 2" INLET/OUTLET CONNECTIOMS 5,8 5, 5. THIS UNIT IS TO PROVIDE COLD WATER TO ICE MAKERS AND COFFEE MAKERS. COORDINATE MOUNTING HEIGHT OF EACH WALL BOX WITH ARCHITECT. UNITS THAT SERVE COFFEE MAKERS SHALL BE INCLUDED A DUAL CHECK, IN-LINE BACKFLOW PREVENETOR, WATTS # SD-2. WASHBROOK 6501.001.020 WALL MOUNTED CONCEALED FLUSH VALVE: HARD-WIRED TYPE. WALL MOUNTED CONCEALED FLUSH VALVE BEMIS #1655CT; WHITE ELONGATED PLASTIC SEAT,OPEN FRONT LESS COVER WALL MOUNTED CONCEALED FLUSH VALVE SLOAN: 195 ES-S SLOAN: 195 ES-S WALL MOUNTED CONCEALED FLUSH VALVE: HARD-WIRED TYPE. ESTATE 0483.000 SH1 1/2" SHOWER ADJUSTABLE SPRAY SHOWER HEAD HAND-HELD SPRAY UNIT, METAL SPIRAL HOSE AND 24" SLIDE BAR 2" 1 1/2" 1/2" SEE ARCHITECTURAL DRAWINGS FOR SHOWER ENCLOSURE AND BASE 6. INSTALL THIS UNIT IN SINK # SK-2. 7. NOT USED 150 GPM @ 12 PSI DROP DOUBLE CHECK DETECTOR ASSEMBLY 750 GPM @ 8 PSI DROP MB-1 MOP BASIN FIAT # MSB-2424 MOLDED STONE 3/4" 3/4" FLOOR 3" 2" 7. FURNISH WITH OPTIONS: # 830-AA, 832-AA, 889-CC,E-88-AA,MSG2424 7, DW-1 DISHWASHER WHIRLPOOL 8212488RC # 1/2" 6 FT. NYLON BRAIDED WATER SUPPLY LINE, 38" BRASS COMPRESSION FITTING WITH ELBOW AND IN-LINE TEE. CONNECT WATER FROM SINK. ALSO SEE DETAIL 1/P-501 8. SEE DETAIL 5/P501 6. SEE DETAIL 12/P-501 9. SEE DETAIL 3/P501 8. PLUMBING CONTRACTOR TO FURNISH ONE 24 VOLT TRANSFORMER TO OPERATE FLUSH VALVES AT EACH FLOOR LEVEL, LOCATE TRANSFORMER ABOVE CEILING. e-705-M-2 - - - SEE ARCHITECTURAL DRAWINGS FOR SHOWER ENCLOSURE AND BASE VALVE POWERS VALVE POWERS e-705-M-2-0-6-Y-W 05/01/18 Nick Mishler