Loading...
HomeMy WebLinkAboutS111-G-GARAGE-PT-PLAN-Rev.2G1 G2 1 2 3 4 5 6 7 8 9 F GA GB GA.6 GA.3 GA.7 8.6 374K 4.00 1.75 6.25 240K 3.00 6.25 6.25 4.50 4.00 4.00 3.00 6.25 1.75 6.25 4.50 6.25 4.00 4.00 1.75 4.00 20 K/FT 4.00 1.75 6.25 6 K/FT 4.00 6.25 3.00 4.00 1.75 6.25 14 K/FT 4.00 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 4.00 4.00 1.75 6.25 14 K/FT 4.00 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 6.25 1.75 4.00 3.00 6.25 1.75 4.00 6 K/FT C.G. C.G. EQ EQ EQ C.G. C.G. PROVIDE (2) TENDONS @ SLAB C.G. FOR TEMP & SHRINKAGE BETWEEN, BEAMS TYP. TENDONS TO BE EQUALLY SPACED IN SPAN. EQ EQ EQ EQ C.G. C.G. C.G. C.G. C.G. C.G. PROVIDE (3) TEMP & SHRINKAGE TENDONS EQUALLY SPACED SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT ARCHITECT MERCHANTS CORPORATE CENTER CARMEL, IN CLIENT # DESCRIPTION DATE NOVEMBER 10, 2017 17104 ISSUED FOR CONSTRUCTION 2017-11-10 S111-G GARAGE PT PLAN S111-G SCALE: 3/32" = 1'-0" 1 INTER. GARAGE LEVEL - PT 1. REF. S001-G FOR STRUCTURAL NOTES, SCHEDULES & DESIGN DATA. 2. REF. S500-G FOR CONCRETE COLUMN SCHEDULE & DETAILS. 3. REF. S400-402-G FOR POST-TENSIONED CONCRETE TYPICAL DETAILS. 4. REF. S110-G LAYOUT PLAN FOR DIMENSIONS TO SLAB EDGES. 5. REF. S112-G MILD REINFORCEMENT PLAN FOR SIZE & SPACING OF MILD REINFORCEMENT. 6. FLOOR CONSTRUCTION: REF. PLAN FOR SLAB THICKNESS, UNBONDED PT ONE WAY AND TWO-WAY CONCRETE SLABS UNO. A. TENDONS ARE UNIFORMLY SPACED IN THE EAST-WEST DIRECTION. B. BANDED TENDONS SPAN IN THE NORTH-SOUTH DIRECTION. C. FORCES SHOWN ON THE PLAN ARE FINAL EFFECTIVE PRESTRESS FORCES. D. TENDON ORDINATES, INDICATED, ARE MEASURED IN INCHES FROM THE BOTTOM OF THE SLAB OR BEAM SOFFIT TO THE CENTERLINE OF THE TENDON. E. ANCHOR TENDONS AT MID-DEPTH OF SLAB AT PERIMETER AND AT OPENINGS. 7. REF. PLAN FOR T.O.S. ELEV. 8. GENERALLY, WHERE TWO LAYERS OF REINFORCING OR TENDONS INTERSECT, PLACE REINFORCING AND TENDONS PARALLEL TO THE NORTH-SOUTH DIRECTION IN THE OUTER MOST LAYER. 9. SLAB TOP BAR AND TOP TENDON COVER - 1" TYP, UNO. SLAB BOTTOM BAR AND BOTTOM TENDON COVER - 1", TYP. UNO. 10. PLAN LEGEND: FF DENOTES FINISH FLOOR T/'X' DENOTES TOP OF WALL, BEAM, ETC. B/'X' DENOTES BOTTOM OF WALL, BEAM, ETC. FD DENOTES FLOOR DRAIN, REF. 'P' DWGS. PD DENOTES PLAZA DRAIN, REF. 'P' DWGS. DENOTES SHEAR WALL HOLDDOWN BD DENOTES BEAM DEPTH 55K/FT DENOTES EFFECTIVE POST-TENSIONING FORCE AFTER ALL LOSSES FOR DISTRIBUTED TENDONS 600K DENOTES EFFECTIVE POST-TENSIONING FORCE AFTER ALL LOSSES FOR BANDED TENDONS DENOTES DEAD END OF TENDON POST TENSIONED PLAN NOTES: 05/01/18 Nick Mishler