Loading...
HomeMy WebLinkAboutS401-G-TYPICAL-PT-PETAILS-Rev.212 1 9" 9" 1 12 12 1 STRAIGHT 39" NOTES: 1. PLACE ANCHORS VERTICALLY IN SLABS GREATER THAN OR EQUAL TO 7" THICK. 2. PLACE ANCHORS HORIZONTALLY IN SLABS LESS THAN 7" THICK LENGTH OF TRANSITION CURVE 5'-0" MIN. STRESSING 1'-0" MIN. FOR C.L. 3" O.C. FOR VERTICAL ANCHORS 6" O.C. FOR HORIZONTAL ANCHORS SUPPORT BARS #3 HAIRPIN TOTAL EQUAL TO NUMBER OF TENDONS PLUS ONE ANCHORS SLAB EDGE (2)-#4@6” O.C., T&B GROMMET AT STRESSING END ONLY SLAB EDGE 2 STRANDS MIN. @ UNSUPPORTED SLAB EDGE, PARALLEL TO UNSUPPORTED EDGE TOP REBAR @ 12" O.C. MAX, TYP. BANDED TENDONS MAX 4 PER BUNDLE DISTRIBUTED TENDON SPACED @ 6 X SLAB THICKNESS OR 48" O.C., MAX. MAX. CURVATURE FOR 7" SLABS OR LARGER, PLACE ANCHOR UPRIGHT @ MIN. 3" O.C. FOR 6 1/2" SLAB OR LESS, PLACE ANCHORS HORIZONTALLY @ 6" O.C. MIN. SLAB EDGE 1'-0", TYP. STAGGER TOP REBAR 1'-0", TYP. STAGGER TOP REBAR 1.5H W 1.5H MILD REINFORCEMENT TO BE DISTRIBUTED WITHIN THE DIMENSION LINES, EA. WAY 1.5H W5H 1. A TOP PT AT CORNER COLUMNS B TOP REBAR AT CORNER COLUMNS NOTE: REBAR NOT SHOWN FOR CLARITY, REF. DETAIL B BELOW FOR REBAR INFORMATION. NOTES: 1. REF. DETAIL A ABOVE FOR ADDITIONAL INFORMATION. 2. TWO STRANDS MIN. TO PASS DIRECTLY OVER COLUMN, EA. WAY. 3. LEGEND: H = SLAB THICKNESS + D W = COL. WIDTH D = CAP/DROP DEPTH BELOW SLAB SOFFIT @ FACE OF COLUMN DISTRIBUTED TENDONS SPACED @ 8 X SLAB THICKNESS OR 60" O.C. MAX., U.N.O. BANDED TENDONS MAX 4 STRANDS PER BUNDLE NOTES: 1. REF. DETAIL A ABOVE FOR ADDITIONAL INFORMATION. 2. TWO STRANDS MIN. TO PASS DIRECTLY OVER COLUMN, EA. WAY. 3. LEGEND: H = SLAB THICKNESS + D W = COL. WIDTH D = CAP/DROP DEPTH BELOW SLAB SOFFIT @ FACE OF COLUMN TOP REBAR, MAX. 12" O.C. MILD REBAR TO BE PLACED WITHIN DIMENSION LINES, EA. WAY 1'-0", TYP. STAGGER TOP REBAR REBAR 1'-0", TYP. STAGGER TOP A TOP PT AT INTERIOR COLUMNS B TOP REBAR AT INTERIOR COLUMNS 1.5H W 1.5H NOTE: REBAR NOT SHOWN FOR CLARITY, REF. DETAIL B BELOW FOR REBAR INFORMATION. 1.5H W 1.5H SLAB EDGE 2 STRANDS MIN. @ UNSUPPORTED SLAB EDGE, PARALLEL TO UNSUPPORTED EDGE BANDED TENDONS MAX 4 PER BUNDLE DISTRIBUTED TENDON SPACED @ 6 X SLAB THICKNESS OR 48" O.C., MAX. MILD REINFORCEMENT TO BE DISTRIBUTED WITHIN THE DIMENSION LINES, EA. WAY MAX. CURVATURE FOR 7" SLABS OR LARGER, PLACE ANCHOR UPRIGHT @ MIN. 3" O.C. FOR 6 1/2" SLAB OR LESS, PLACE ANCHORS HORIZONTALLY @ 6" O.C. MIN. SLAB EDGE NOTE: REBAR NOT SHOWN FOR CLARITY, REF. DETAIL B BELOW FOR REBAR INFORMATION. A TOP PT AT EXTERIOR COLUMNS B TOP REBAR AT EXTERIOR COLUMNS 1'-0", TYP. STAGGER TOP REBAR 1'-0", TYP. STAGGER TOP REBAR TOP REBAR @ 12" O.C. MAX, TYP. 1.5H W 1.5H 1.5H W5H 1. NOTES: 1. REF. DETAIL A ABOVE FOR ADDITIONAL INFORMATION. 2. TWO STRANDS MIN. TO PASS DIRECTLY OVER COLUMN, EA. WAY. 3. LEGEND: H = SLAB THICKNESS + D W = COL. WIDTH D = CAP/DROP DEPTH BELOW SLAB SOFFIT @ FACE OF COLUMN SLAB EDGE 2 STRANDS MIN. @ UNSUPPORTED SLAB EDGE, PARALLEL TO UNSUPPORTED EDGE TOP REBAR @ 12" O.C. MAX, TYP. BANDED TENDONS MAX 4 PER BUNDLE DISTRIBUTED TENDON SPACED @ 6 X SLAB THICKNESS OR 48" O.C., MAX. MILD REINFORCEMENT TO BE DISTRIBUTED WITHIN THE DIMENSION LINES, EA. WAY SLAB EDGE REBAR 1'-0", TYP. STAGGER TOP REBAR 1'-0", TYP. STAGGER TOP 1.5H W 1.5H 1.5H W5H 1. A TOP PT AT CORNER COLUMNS B TOP REBAR AT CORNER COLUMNS NOTE: REBAR NOT SHOWN FOR CLARITY, REF. DETAIL B BELOW FOR REBAR INFORMATION. NOTES: 1. REF. DETAIL A ABOVE FOR ADDITIONAL INFORMATION. 2. TWO STRANDS MIN. TO PASS DIRECTLY OVER COLUMN, EA. WAY. 3. LEGEND: H = SLAB THICKNESS + D W = COL. WIDTH D = CAP/DROP DEPTH BELOW SLAB SOFFIT @ FACE OF COLUMN LOWER LAYER OF TOP REBAR, REF. PLAN #7 SUPPORT REBAR CHAIR TYP. PT SLAB REF. PLAN UNIFORMLY DISTRIBUTED PT TENDON UPPER LAYER OF TOP REBAR, REF. PLAN BANDED PT TENDON MIN., TYP. 2" CLR. T.O.C. EL. REF. PLAN LOWER LAYER OF TOP REBAR, REF. PLAN #7 SUPPORT REBAR CHAIR TYP. PT SLAB REF. PLAN BANDED PT TENDONS, NUMBER OF TENDONS PER BUNDLE MAY VARY UPPER LAYER OF TOP REBAR, REF. PLAN MIN., TYP. 2" CLR. T.O.C. EL. REF. PLAN UNIFORMLY DISTRIBUTED PT TENDON PT SLAB REF. PLAN h s<60" s<8h NOTE: S>d+2(NUMBER OF BARS) FOR 3/4" OR SMALLER AGGREGATE AND #8 BARS OR SMALLER. ALLOW GREATER SPACING FOR OTHER CONDITIONS. PT SLAB REF. PLAN h TENDON s>d db REBAR d s MAXIMUM SPACING A OF DISTRIBUTED TENDONS MINIMUM SPACING B BETWEEN BUNDLED TENDONS SUPPORT BAR OR SLAB BOLSTER UNIFORM TENDONS CLR. 2" MIN. BOTTOM REINF. REF. PLAN (1)-#4 CONT. GENERAL NOTES MIN. COVER, REF. SUPPORT WIDTH EQ EQ BANDED TENDONS (2)-#7 SUPPORT BARS, TYP. @ COL. SUPPORTS, ONE EA. SIDE BANDED TENDONS PLACE TOP REBAR WITHIN THIS STRIP 1.5T COL. WIDTH 1.5T SCHED. CONC. COLUMN REF. COL. SCHEDULE FOR REINF. PLACE DISTRIBUTED TENDONS WHICH FALL WITHIN THE LENGTHS OF TOP REBARS BELOW THE UPPERMOST LAYER OF REBAR. PLACE REMAINDER OF DISTRIBUTED TENDONS AS SHOWN ON PLANS T REF. PLAN NOTE: A MINIMUM OF TWO TENDONS SHALL BE PLACED IN EA. DIRECTION DIRECTLY OVER COL. REF. PLAN FOR TOP OF COL. REBAR DISTRIBUTED TENDONS UNDER BANDED TENDONS AT COLUMN HOOK COL. DOWELS AT TOP FLOOR COL. TO BE POURED FLUSH OR BELOW SLAB SOFFIT SCHED. REF. 0' - 0' 3" - 3" 0' - 2" PT SLAB, REF. PLAN T.O.C. EL. REF. PLAN (4)-#4X9'-0", E.W. U.N.O. ON PLAN (2)-#7 SUPPORT BARS, TYP. @ COL. SUPPORTS, ONE EA. SIDE COL. WIDTH REF. COL. SCHED. FOR SCHED. CONC. COLUMN REINF. PLACE DISTRIBUTED TENDONS WHICH FALL WITHIN THE LENGTHS OF TOP REBARS BELOW THE UPPERMOST LAYER OF REBAR. PLACE REMAINDER OF DISTRIBUTED TENDONS AS SHOWN ON PLANS NOTE: A MINIMUM OF TWO TENDONS SHALL BE PLACED IN EA. DIRECTION DIRECTLY OVER COL. HOOK COL. DOWELS AT TOP FLOOR COL. TO BE POURED FLUSH OR BELOW SLAB SOFFIT SCHED. REF. 3"3" 2" PT SLAB, REF. PLAN T REF. PLAN BANDED TENDONS T.O.C. EL. REF. PLAN (4)-#4X9'-0", E.W. U.N.O. ON PLAN. HOOK AT DISCONTINUOUS END SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT ARCHITECT MERCHANTS CORPORATE CENTER CARMEL, IN CLIENT # DESCRIPTION DATE NOVEMBER 10, 2017 17104 ISSUED FOR CONSTRUCTION 2017-11-10 S401-G TYPICAL PT DETAILS S401-G SCALE: NONE 5 FLARING AT BANDED TENDONS AT SLAB EDGE S401-G SCALE: NONE 3 TOP REINF. AT CORNER COLUMNS S401-G SCALE: NONE 1 TOP REINFORCEMENT AT INTERIOR COLUMNS S401-G SCALE: NONE 2 TOP REINFORCEMENT AT EXTERIOR COLUMNS S401-G SCALE: NONE 4 TOP REINF. AT INTERIOR CORNER COLUMNS S401-G SCALE: 3/4" = 1'-0" 10 SECTION THROUGH DISTRIBUTED TENDON AT COLUMN S401-G SCALE: 3/4" = 1'-0" 11 SECTION THROUGH BANDED TENDON AT COLUMN S401-G SCALE: 3/4" = 1'-0" 6 SPACING BETWEEN TENDONS S401-G SCALE: 3/4" = 1'-0" 9 BANDED TENDONS AT LOW POINT S401-G SCALE: 3/4" = 1'-0" 8 TYPICAL INTERIOR COLUMN S401-G SCALE: 3/4" = 1'-0" 7 TYPICAL EXTERIOR COLUMN 05/01/18 Nick Mishler