HomeMy WebLinkAboutS402-G-TYPICAL-PT-DETAIL5-Rev.21 12 ? ? 3'-0" 6" MAX. DIM. REINFORCEMENT 12" TO 18" (1)-#5 EA. SIDE 18" TO 2'-6" (1)-#5 T&B, EA. SIDE 2'-6" OR LARGER (2)-#5 T&B, EA. SIDE NOTES: 1. ALL OPENINGS LARGER THAN 12" SHALL BE TRIMMED AS SHOWN. 2. THESE BARS ARE IN ADDITION TO REBAR SHOWN ON PLANS. PT TENDON W/ SMOOTH CURVE TYP. 3" CLR. TYP. 1 1/2" CLR. TYP. 2'-0" MIN. (1)-#5X3'-0" T&B TYP. FOR LARGER THAN 24" OPNG. MAX. DIM. REINFORCEMENT 12" TO 18" (1)-#5 EA. SIDE 18" TO 2'-6" (1)-#5 T&B, EA. SIDE 2'-6" OR LARGER (2)-#5 T&B, EA. SIDE NOTES: 1. ALL OPENINGS LARGER THAN 12" SHALL BE TRIMMED AS SHOWN. 2. THESE BARS ARE IN ADDITION TO REBAR SHOWN ON PLANS. PT TENDON W/ SMOOTH CURVE TYP. 1 1/2" CLR. (1)-#5X3'-0", T&B TYP. FOR MORE THAN 24" OPNG. SLAB EDGE TYP. 2'-0" MIN. TYP. 24" MIN. 36" TYP. TYP. 3" CLR. 45° TYP. STEEL PIPE INSERT (SCHED.40) IS REQD. WHEN SLAB PENETRATION IS WITHIN 45 BEARING CONE OF TENDON ANCHOR W D PT TENDON SLAB EDGE CLR. 2 1 /2" PENETRATIONS FARTHER THAN 1.5 TIMES THE DIAMETER (D) OR WIDTH (W) BUT NOT LESS THAN 18" MIN. FROM ANCHOR, DO NOT REQUIRE STEEL PIPE INSERT CLR. 2 1/2" 1.5W OR 1.5D MIN. 18" 6" MIN. PT CONE OF INFLUENCE SLAB EDGE #5X7'-0" T&B 3'-0" 3'-0" #5X6'-0" T&B TRIM BARS 8" MIN. 24" MIN. D1 <D1 D2 EFFECTIVE LENGTH D1 ≤D1 D2 ≤D3 D3 NOTES: 1. INSERTS WHICH ARE CLOSER TO ONE ANOTHER THAN THE DIAMETER OF THE LARGER OF THE TWO ARE CONSIDERED TO FORM A COMBINED OPENING. 2. IF THE COMBINED OPENING IS LESS THAN 12" NO TRIM BARS ARE REQUIRED. 3. IF THE COMBINED OPENING IS MORE THAN 12", BUT LESS THAN 24", PROVIDE (1)-#5 T&B WITH 1'-0" EMBEDMENT PAST THE OPENING. 4. IF COMBINED OPENING IS LARGER THAN 24", REFER TO 1 / S402-. G PT TENDON CLR. 3" MIN. STRAIGHT 3'-0" MIN. REF. WHERE TENDON CURVATURE EXCEEDS 1:12, REF. TYP. MAX. CURVATURE 24" MIN. DISTANCE OF STRAIGHT TENDON PAST EDGE OF OPENING 9 / S402-G 9 / S402-G 1/3 PT 1/3 PT 1/3 PT PT SLAB PT TENDON NOTE: PT IS POST-TENSIONING ASSOCIATED WITH OPENING OR LARGER OPENING 6'-0" NOTE: 1. WHERE TENDON TURN IS MORE THAN 1:12, KEEP TENDONS MIN. 2" APART AT TURN. 2. PLACE HAIRPIN PER B/SECTION AT OPENING. 2" GAP BETWEEN TENDONS 12 >=1 2'-0", TYP. OPENING OR CENTER PT SLAB OF TENDON TURN EDGE OF OPENING WHERE IT OCCURS PT TENDON REF. PLAN #4 HAIRPIN PLACED RADIALLY TO HOLD TENDONS IN PLANE OF SLAB PLACE OVER CURVED LENGTH OF TENDON AT (72"/NUMBER OF STRANDS) IN. ON CENTER BUT NOT MORE THAN 18 INCHES APART C SECTION PT TENDON REF. PLAN HAIRPIN A PLAN B SECTION AT OPENING N, NUMBER OF TENDONS 3" TYP. ADD. (4)-#4 A SECTION 30" MIN. 24" MIN. 3N+5" 3" MAX. NOTES: 1. IF BLOCKOUT IS EXPOSED TO WEATHERING AND OR MOISTURE USE GROMMETS; CUT STRESSED STRANDS TAILS; PREPARE AND SEAL STRESSING POCKETS AS STIPULATED IN GENERAL NOTES; CAULK JOINT ALL AROUND. 2. CONTINUE ALL INTERRUPTED BARS SHOWN IN PLANS THROUGH THE BLOCKOUT. 3. FILL BLOCKOUT WITH NON-SHRINK CONCRETE REPAIR MATERIAL OF SAME SPECIFIED STRENGTH AS SLAB CONCRETE. B SECTION SHEAR KEY 3" X 1/2" TYP. STRAND TAILS REF. NOTES REF. NOTES PT SLAB REF. PLAN SLAB EDGE (1)-#4 T&B ≤12" 18" MIN. REF. ARCH. DRAWINGS 12" MIN. 3'-0" MIN. (1)-#4 T&B, TYP. ADDED REINF., U.N.O. PT SLAB REF. PLAN 6'-0" MIN. PT SLAB REF. PLAN TROWEL EDGE 1/2" 1 /2 " 2 1/2" MIN. CONT. DRIP, 3/4" MAX. PT SLAB REF. PLAN (4)-#5X8'-0" @ 6" O.C. E.W., U.N.O. ON PLAN COLUMN OR OTHER CONCENTRATED LOAD SLAB THICKNESS REBAR SPACING 12" O.C. 10" O.C. 8" O.C. 12" O.C. 8" OR LESS 8"<T<10" 10"<T<14" 14"<T<18" REINFORCEMENT 18"<T<20" 20"<T<24" 10" O.C. 9" O.C. PT SLAB REF. PLAN 45° 45° ALTERNATE T&B SLAB EDGE CONC. BEAM BEAM OR BANDED TENDONS 2 4 " NOTE: 1. PLACE SINGLE LAYERS AT MID-DEPTH OF SLAB. 2. PLACE TWO LAYERS AT TOP AND BOTTOM OF SLAB. NUMBER OF LAYERS 1 2 1 2 1 2 SHEET PROJECT INFO SEAL REVISIONS DRAWING TITLE PROJECT ARCHITECT MERCHANTS CORPORATE CENTER CARMEL, IN CLIENT # DESCRIPTION DATE NOVEMBER 10, 2017 17104 ISSUED FOR CONSTRUCTION 2017-11-10 S402-G TYPICAL PT DETAILS S402-G SCALE: NONE 1 MINIMUM TRIM BARS FOR INTERIOR OPENING IN SLAB S402-G SCALE: NONE 2 MINIMUM TRIM BARS AT SLAB EDGE OPENINGS S402-G SCALE: NONE 6 REINFORCEMENT AT ANCHORAGE ZONE PENETRATIONS S402-G SCALE: NONE 3 TRIM BARS AT INTERIOR CORNERS S402-G SCALE: NONE 7 TRIM BARS FOR MULTIPLE OPENINGS S402-G SCALE: NONE 8 TENDON PLACEMENT AT OPENING 24" OR LARGER S402-G SCALE: NONE 11 ARRANGEMENT OF TENDONS AT OPENING 6'-0" OR LARGER S402-G SCALE: NONE 9 TENDON PLACEMENT FOR TURNS MORE THAN 1:12 S402-G SCALE: NONE 10 INTERNAL STRESSING BLOCK OUT S402-G SCALE: NONE 4 MINIMUM SLAB EDGE REINFORCEMENT S402-G SCALE: NONE 5 TRIM BARS AT CANTILEVERED SLAB S402-G SCALE: 3/4" = 1'-0" 12 CONTINUOUS DRIP EDGE AT EXTERIOR SLAB OVERHANG S402-G SCALE: 3/4" = 1'-0" 13 MINIMUM REINFORCEMENT BELOW CONCENTRATED LOAD S402-G SCALE: 3/4" = 1'-0" 14 TEMPERATURE REINFORCEMENT BETWEEN BANDED TENDONS AND/OR BEAMS 05/01/18 Nick Mishler