HomeMy WebLinkAboutPrairie at Legacy 1203 Truss detailsRe:
IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed
in the jurisdictions(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific
information included is for MiTek’s customer’s file reference purpose only, and was not taken into account in the preparation
of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any
particular building. Before use, the building designer should verify applicability of the design parameters and properly
incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2.
The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by Timberland Home Center-Brazil, IN.
Liu, Xuegang
FOXHALL B
Pages or sheets covered by this seal: I25088925 thru I25088934
My license renewal date for the state of Indiana is July 31, 2016.
1500362
14515 North Outer Forty Drive
Suite 300
Chesterfield, MO 63017-5746
314-434-1200
MiTek USA, Inc.
October 13,2015
Job
1500362
Truss
A
Truss Type
COMMON
Qty
11
Ply
1
FOXHALL B
Job Reference (optional)
I25088925
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:29 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-D5jSPgTgPmgQHmQUGoOaAicpjwBlhkLtRSiz?ByTnam
Scale = 1:74.1
1 2
3
4 5
6
7
8
9
10
11
17 16 15 14 13 12
18 193x8
5x6
3x6
3x8 3x4
4x6
3x4
3x8
3x4
3x4
2x4
2x8
3x8 3x6
4x9
8-3-10
8-3-10
18-11-15
10-8-5
29-8-0
10-8-1
40-0-0
10-4-0
-0-11-4
0-11-4
5-3-10
5-3-10
12-1-15
6-10-5
18-11-15
6-10-0
25-9-12
6-9-14
32-7-10
6-9-14
40-0-0
7-4-6
40-11-4
0-11-4
1-4-410-10-30-4-36.00 12
Plate Offsets (X,Y)-- [10:0-0-0,0-0-4]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.83
0.90
0.66
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.25
-0.74
0.16
(loc)
10-12
10-12
10
l/defl
>999
>647
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 169 lb FT = 0%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF-S 1650F 1.6E *Except*
13-15: 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
5-14,6-14,7-14: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-4-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-14, 7-14, 3-17
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)17=1653/0-3-8, 10=1653/0-3-8
Max Horz 17=-5(LC 6)
Max Uplift17=-245(LC 6), 10=-247(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-2295/358, 4-5=-2108/361, 5-18=-1799/329, 6-18=-1698/362, 6-19=-1698/362,
7-19=-1797/329, 7-8=-2529/409, 8-9=-2696/375, 9-10=-2958/416, 2-17=-300/133
BOT CHORD 16-17=-186/1947, 15-16=-115/1888, 14-15=-115/1888, 13-14=-131/2042,
12-13=-131/2042, 10-12=-268/2572
WEBS 5-16=0/314, 5-14=-639/198, 6-14=-173/1147, 7-14=-843/220, 7-12=-23/629,
9-12=-383/197, 3-17=-2212/258
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 17=245,
10=247.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V1
Truss Type
GABLE
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088926
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:30 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-hHHqc0UIA4oHvw?gqWvpjw99vKkMQJa0f6RWXdyTnal
Scale = 1:55.8
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
5
6
7 8
9
10
11
12
13
14
15
16
17
18
19
35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
3x4
4x6
3x4
3x4
3x4
3x4
24-0-3
24-0-3
12-0-2
12-0-2
24-0-3
12-0-2
9-0-19.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.10
0.04
0.15
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
19
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 141 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3 *Except*
1-8,12-19: 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3 *Except*
10-27: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 10-27
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 24-0-3.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 28, 30, 31, 32, 33, 34, 35, 26, 25,
24, 23, 22, 21, 20
Max Grav All reactions 250 lb or less at joint(s) 1, 27, 28, 30, 31, 32, 19, 33, 34,
35, 26, 25, 24, 23, 22, 21, 20
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 30, 31, 32, 33, 34,
35, 26, 25, 24, 23, 22, 21, 20.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V2
Truss Type
VALLEY
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088927
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:31 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-9UrCqMUwxOw8W4asODQ2F7hJMk1b9l5AumB333yTnak
Scale = 1:49.7
1
2
3
4
5
6
7
13 12 11 10 9 8
14 15
3x4
4x6
3x4
3x4
21-4-3
21-4-3
10-8-2
10-8-2
21-4-3
10-8-2
8-0-19.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.18
0.17
0.20
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 76 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
1-11: 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 21-4-3.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 9, 8
Max Grav All reactions 250 lb or less at joint(s) 1, 7, 10 except 12=375(LC 7), 13=276(LC 1), 9=375(LC 8),
8=276(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-12=-293/145, 5-9=-293/145
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9, 8.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V3
Truss Type
VALLEY
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088928
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:32 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-egPa1hVZhh2?8E83yxxHoLES08KuuDNJ7QwdbWyTnaj
Scale = 1:43.6
1
2
3
4
5
9 8 7 6
10 11
3x4
4x6
3x4
3x4 2x4 2x4
2x4
2x4
2x4
18-8-3
18-8-3
9-4-2
9-4-2
18-8-3
9-4-2
7-0-19.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.31
0.36
0.13
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 62 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
5-7: 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 18-8-3.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-119(LC 6), 6=-119(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=452(LC 7), 6=452(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-336/172, 4-6=-337/173
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 119 lb uplift at joint 9 and 119 lb uplift at
joint 6.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V4
Truss Type
VALLEY
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088929
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:32 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-egPa1hVZhh2?8E83yxxHoLEUJ8O_uEiJ7QwdbWyTnaj
Scale = 1:39.2
1
2
3
4
5
8 7 6
9 10
3x4
4x6
3x4
5x6 2x4
2x4
2x4
2x4
16-0-3
16-0-3
8-0-2
8-0-2
16-0-3
8-0-2
6-0-19.00 12
Plate Offsets (X,Y)-- [7:0-3-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.17
0.09
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 52 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 16-0-3.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) except 8=-101(LC 6), 6=-101(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=368(LC 7), 6=368(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-278/146, 4-6=-278/146
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 8 and 101 lb uplift at
joint 6.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V5
Truss Type
VALLEY
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088930
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:33 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-6syyE1WBS?AsmOjFVeSWKYmcWXkCdgMSM4gA8yyTnai
Scale = 1:32.6
1
2
3
4
5
8 7 6
9 10
3x4
4x6
3x4
2x4 2x4
2x4
2x4
2x4
13-4-3
13-4-3
6-8-2
6-8-2
13-4-3
6-8-2
5-0-19.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.33
0.09
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 41 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-4-3.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 8, 6
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=255(LC 1), 8=308(LC 7), 6=308(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V6
Truss Type
VALLEY
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088931
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:34 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-a3WLSNXpDJIjNYIR3M_ltmJnrx1mM7ecakPkgOyTnah
Scale = 1:26.6
1
2
3
4
5 6
2x8
4x6
2x8
2x4
10-8-3
10-8-3
5-4-2
5-4-2
10-8-3
5-4-2
4-0-19.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.36
0.27
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 30 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=199/10-8-3, 3=199/10-8-3, 4=386/10-8-3
Max Uplift1=-33(LC 6), 3=-33(LC 6), 4=-4(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V7
Truss Type
VALLEY
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088932
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:34 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-a3WLSNXpDJIjNYIR3M_ltmJnRx3jM8EcakPkgOyTnah
Scale = 1:21.4
1
2
3
4
5 6
2x4
4x6
2x4 2x4
8-0-3
8-0-3
4-0-2
4-0-2
8-0-3
4-0-2
3-0-19.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.38
0.14
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 22 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=159/8-0-3, 3=159/8-0-3, 4=254/8-0-3
Max Uplift1=-37(LC 6), 3=-37(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V8
Truss Type
VALLEY
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088933
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:35 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-2F4jfjXR_cQZ?htdd3V_Qzs?pLLz5b8lpO9HCryTnag
Scale = 1:15.6
1
2
3
2x4
3x4
2x4
5-4-3
5-4-3
2-8-2
2-8-2
5-4-3
2-8-2
2-0-19.00 12
Plate Offsets (X,Y)-- [2:0-2-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.15
0.40
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 13 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-4-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=179/5-4-3, 3=179/5-4-3
Max Uplift1=-22(LC 6), 3=-22(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
Job
1500362
Truss
V9
Truss Type
VALLEY
Qty
1
Ply
1
FOXHALL B
Job Reference (optional)
I25088934
7.640 s Sep 29 2015 MiTek Industries, Inc. Tue Oct 13 15:36:35 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:bGeFAYaFjKIpKe8hqe4aIpzZg4n-2F4jfjXR_cQZ?htdd3V_Qzs1nLQ55b8lpO9HCryTnag
Scale: 1.5"=1’
1
2
3
2x4
3x4
2x4
2-8-3
2-8-3
1-4-2
1-4-2
2-8-3
1-4-2
1-0-19.00 12
Plate Offsets (X,Y)-- [2:0-2-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.02
0.07
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 6 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)1=72/2-8-3, 3=72/2-8-3
Max Uplift1=-9(LC 4), 3=-9(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
October 13,2015
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.