Loading...
HomeMy WebLinkAbout42200051 - JGC 185 - Energy CertificateEnergy Code Inspection Checklist Property David Weekley Homes 12179 Ams Run Carmel, IN 46032 Weather:Indianapolis, IN 5876 BRUNSON BST DAVIN-JG-5876 BRUNSON BST-DIA.blg Organization TopBuild Home Services 866-912-7233 Alan Smith Builder David Weekley Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 4/4/2018 Building Information Conditioned Area (sq ft)5062 Conditioned Volume (cubic ft)48537 Insulated Shell Area (sq ft)9999 The building assemblies and the energy features listed below have been modeled to demonstrate compliance with the IECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. TopBuild Home Services's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings [ ]1.Attic: R-38 Blown, Attic***************** (2838 s.f.) R-25.0 continuous insulation, R-13.0 cavity insulation. Name: Ceiling, All Insulation Grade: I II III Face / Inset Comments/Location Above-Grade Walls [ ]1.Wall: R-19 24oc AF R-3.3* (2311 s.f.), Between conditioned space and ambient R-3.3 continuous insulation, R-19.0 cavity insulation. Name: Ambient Insulation Grade: I II III Face / Inset Comments/Location [ ]2.Wall: R-19 (2x6)*** (414 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-19.0 cavity insulation. Name: Garage Insulation Grade: I II III Face / Inset Comments/Location Windows and Skylights Window-to-Wall Area Ratio: 0.20 [ ]1.Window: U .28, SHGC .29* (60 s.f., East), U-Value: 0.280, SHGC: 0.290 For windows without labeled U-factors, describe features: Name: Front Orientation: East Comments/Location Energy Code Inspection Checklist Property David Weekley Homes 12179 Ams Run Carmel, IN 46032 Weather:Indianapolis, IN 5876 BRUNSON BST DAVIN-JG-5876 BRUNSON BST-DIA.blg Organization TopBuild Home Services 866-912-7233 Alan Smith Builder David Weekley Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 4/4/2018 Page 2 of 6 Windows and Skylights [ ]2.Window: U .28, SHGC .29* (6 s.f., East), U-Value: 0.280, SHGC: 0.290 For windows without labeled U-factors, describe features: Name: Front fr dr Orientation: East Comments/Location [ ]3.Window: U .28, SHGC .29* (114 s.f., South), U-Value: 0.280, SHGC: 0.290 For windows without labeled U-factors, describe features: Name: Left Orientation: South Comments/Location [ ]4.Window: U .28, SHGC .29* (21 s.f., South), U-Value: 0.280, SHGC: 0.290 For windows without labeled U-factors, describe features: Name: Left fr dr Orientation: South Comments/Location [ ]5.Window: U .28, SHGC .29* (255 s.f., West), U-Value: 0.280, SHGC: 0.290 For windows without labeled U-factors, describe features: Name: Back Orientation: West Comments/Location [ ]6.Window: U .28, SHGC .29* (21 s.f., West), U-Value: 0.280, SHGC: 0.290 For windows without labeled U-factors, describe features: Name: Back fr dr Orientation: West Comments/Location [ ]7.Window: U .28, SHGC .29* (62 s.f., North), U-Value: 0.280, SHGC: 0.290 For windows without labeled U-factors, describe features: Name: Right Orientation: North Comments/Location Energy Code Inspection Checklist Property David Weekley Homes 12179 Ams Run Carmel, IN 46032 Weather:Indianapolis, IN 5876 BRUNSON BST DAVIN-JG-5876 BRUNSON BST-DIA.blg Organization TopBuild Home Services 866-912-7233 Alan Smith Builder David Weekley Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 4/4/2018 Page 3 of 6 Doors [ ]1.Door: Steel-urth w/brk******************* (18 s.f.), R-Value 4.4 Comments/Location [ ]2.Door: Steel-urth w/brk******************* (18 s.f.), R-Value 4.4 Comments/Location Frame Floors [ ]1.Floor: Uninsulated******************* (614 s.f.), Between conditioned space and enclosed crawl space R-0.0 continuous insulation, R-0.0 cavity insulation. Name: Over Crawl Insulation Grade: I II III Face / Inset Comments/Location Slab Floors [ ]1.Slab: Uninsulated (2224 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: Slab, Basement Insulation Grade: I II III Face / Inset Comments/Location Foundation Walls [ ]1.Wall: R-5 Ext, 8ft deep******************* (1426 s.f.), Between conditioned space and ambient/ground R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-5.0 exterior insulation. Name: Basement-Ambient Insulation Grade: I II III Face / Inset Comments/Location [ ]2.Wall: R-5 Ext, 8ft deep******************* (320 s.f.), Between conditioned space and garage/ground R-0.0 interior continuous insulation, R-0.0 interior cavity insulation, R-5.0 exterior insulation. Name: Basement-Garage Insulation Grade: I II III Face / Inset Comments/Location Energy Code Inspection Checklist Property David Weekley Homes 12179 Ams Run Carmel, IN 46032 Weather:Indianapolis, IN 5876 BRUNSON BST DAVIN-JG-5876 BRUNSON BST-DIA.blg Organization TopBuild Home Services 866-912-7233 Alan Smith Builder David Weekley Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 4/4/2018 Page 4 of 6 Foundation Walls [ ]3.Wall: R-11 Draped, 4ft*0**************** (290 s.f.), Between enclosed crawl space and ambient/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: Crawl-Ambient Insulation Grade: I II III Face / Inset Comments/Location [ ]4.Wall: R-11 Draped, 4ft*0**************** (23 s.f.), Between enclosed crawl space and garage/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: Crawl-Garage Insulation Grade: I II III Face / Inset Comments/Location Rim and Band Joists [ ]1.Joist: Ambient (153 s.f.), Between conditioned space and ambient R-3.3 continuous insulation, R-19.0 cavity insulation. Name: Ambient Insulation Grade: I II III Face / Inset Comments/Location Mechanical Equipment [ ]1.Heating: Fuel-fired air distribution, Natural gas, 93.0 AFUE. Make and Model Number [ ]2.Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number [ ]3.Water Heating: Conventional, Natural gas, 0.65 EF, 50.0 Gal. Make and Model Number Mechanical Ventilation System [ ]Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Air Cycler, 111 cfm, 24.0 hrs/day, 280.0 watts, No ECM Fan Motor. System description(make) Air Leakage Control [ ]Blower Door Test at Final __________________________ Energy Code Inspection Checklist Property David Weekley Homes 12179 Ams Run Carmel, IN 46032 Weather:Indianapolis, IN 5876 BRUNSON BST DAVIN-JG-5876 BRUNSON BST-DIA.blg Organization TopBuild Home Services 866-912-7233 Alan Smith Builder David Weekley Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 4/4/2018 Page 5 of 6 Air Leakage Control [ ]House is air-sealed so as to achieve 1.37 ELA/100sh or less at final blower door test. (Max CFM50 is: 2495) [ ]Visual inspection at rough for mandatory code air barrier and insulation features. Infiltration Requirements for IECC 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage and Insulation [ ]Duct System 1 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ]Duct System 1 Leakage to Outside is specified in REM/Rate at 0.030 CFM25 / CFA [ ]Duct System 1 Total Duct Leakage is specified in REM/Rate at 0.040 CFM25 / CFA Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): Requires ducts be tested and reported, but has no compliance thresholds. Notes Energy Code Inspection Checklist Property David Weekley Homes 12179 Ams Run Carmel, IN 46032 Weather:Indianapolis, IN 5876 BRUNSON BST DAVIN-JG-5876 BRUNSON BST-DIA.blg Organization TopBuild Home Services 866-912-7233 Alan Smith Builder David Weekley Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 4/4/2018 Page 6 of 6 Notes 2009 IECC Energy Cost Compliance Property David Weekley Homes 12179 Ams Run Carmel, IN 46032 Weather:Indianapolis, IN 5876 BRUNSON BST DAVIN-JG-5876 BRUNSON Organization TopBuild Home Services 866-912-7233 Alan Smith Builder David Weekley Homes HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Annual Energy Cost $/yr 2009 IECC As Designed Heating 254 234 Cooling 153 121 Water Heating 46 46 SubTotal - Used to Determine Compliance 452 401 Lights & Appliances 591 666 Photovoltaics -0 -0 Service Charge 248 248 Total 1291 1315 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.2)PASSES Duct Leakage (Section 403.2.2)PASSES Mandatory Requirements Check Box (2009 IECC)PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 11.3%. Name Alan Smith Signature Organization TopBuild Home Services Date 4 April 2018 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 12179 Ams Run, Carmel, IN by David Weekley Homes exceeds the minimum requirements for the 2009 International Energy Conservation Code The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Building Features Ceiling Flat R-38.0 Duct NA Sealed Attic:NA Duct Leakage to Outside:0.03 CFM25 / CFA Vaulted Ceiling NA Total Duct Leakage:0.04 CFM25 / CFA Above Grade Walls R-22.3 Infiltration:Htg: 1.37 Clg: 1.37 ELA/100sh Foundation Walls R-5.0 Window U-Value: 0.280, SHGC: 0.290 Exposed Floor R-0.0 Heating Fuel-fired air distribution, Natural gas, 93.0 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Natural gas, 0.65 EF, 50.0 Gal. Name Alan Smith Signature Organization TopBuild Home Services Date 4 April 2018