Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Trusses
Re: Liu, Xuegang Pages or sheets covered by this seal: I32548884 thru I32548948 My license renewal date for the state of Indiana is July 31, 2018. B18800879 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: 212 BRIDGEMONT AT JACKSONS GRA The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. February 27,2018 Job B18800879 Truss AT01 Truss Type Attic Qty 2 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548884 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:29 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-i1EupUfv4AQaqDpku_yQ4XfF9?mBAUSDxG_l7Vzh_lS Scale = 1:86.0 1 2 34 5 6 7 8 9 10 11 12 13 14 20 19 18 17 16 15 25 26 27 4x6 6x6 5x8 4x6 3x4 10x10 3x6 2x4 2x4 10x10 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 4x6 2x4 6x6 6x6 5x6 5x6 13-10-0 8-1-144-8-14 4-8-14 9-2-4 4-5-6 23-3-12 14-1-8 27-9-2 4-5-6 32-6-0 4-8-14 -0-10-8 0-10-8 4-8-14 4-8-14 9-2-4 4-5-6 9-5-2 0-2-14 10-1-11 0-8-9 12-8-2 2-6-7 19-9-14 7-1-13 22-4-5 2-6-7 23-0-14 0-8-9 23-3-12 0-2-14 27-9-2 4-5-6 32-6-0 4-8-14 33-4-8 0-10-8 1-5-412-0-01-5-412-0-010.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [8:0-5-4,0-2-12], [13:0-3-0,0-1-12], [17:0-4-12,0-5-0], [18:0-4-12,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.65 0.63 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.30 0.03 0.11 (loc) 17-18 17-18 15 18-19 l/defl >999 >999 n/a >999 L/d 480 360 n/a 240 PLATES MT20 Weight: 293 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SP No.1 BOT CHORD 2x6 SP 2400F 2.0E *Except* 17-18: onCENTER® AFL 2.1E 1 1/2" x 11 7/8" WEBS 2x4 SPF-S Stud *Except* 5-18,10-17,6-9: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-3 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-8. BOT CHORD Rigid ceiling directly applied or 9-9-10 oc bracing. WEBS 1 Row at midpt 25-26 JOINTS 1 Brace at Jt(s): 25, 26 REACTIONS.(lb/size) 20=1849/0-3-8, 15=1783/0-3-8 Max Horz 20=225(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2107/0, 3-4=-2203/0, 4-5=-2190/0, 5-6=-1484/26, 6-7=-433/116, 7-8=-287/141, 8-9=-436/113, 9-10=-1493/26, 10-11=-2174/0, 11-12=-2187/0, 12-13=-1998/0, 2-20=-1777/0, 13-15=-1689/0 BOT CHORD 19-27=0/1568, 18-27=0/1573, 17-18=0/1608, 16-17=0/1487 WEBS 5-18=0/923, 10-17=0/882, 12-17=-147/347, 6-25=-1355/0, 25-26=-1361/0, 9-26=-1365/0, 3-19=-409/62, 12-16=-537/68, 2-19=0/1447, 13-16=0/1350 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Ceiling dead load (5.0 psf) on member(s). 5-6, 9-10, 6-25, 25-26, 9-26; Wall dead load (5.0psf) on member(s).5-18, 10-17 7) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 17-18 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Attic room checked for L/360 deflection. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss AT02 Truss Type ATTIC Qty 12 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548885 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:30 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-ADoH0qgYrUYQRNOxSiUfdlBQuP6OvxZM9wkIfxzh_lR Scale = 1:86.0 1 23 4 5 6 7 8 9 10 11 12 13 19 18 17 16 15 14 24 25 26 4x6 6x6 5x8 4x6 3x4 10x10 3x6 2x4 2x4 10x10 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 4x6 2x4 6x6 6x6 4x6 5x6 13-10-0 8-1-144-8-14 4-8-14 9-2-4 4-5-6 23-3-12 14-1-8 27-9-2 4-5-6 32-6-0 4-8-14 4-8-14 4-8-14 9-2-4 4-5-6 9-5-2 0-2-14 10-1-11 0-8-9 12-8-2 2-6-7 19-9-14 7-1-13 22-4-5 2-6-7 23-0-14 0-8-9 23-3-12 0-2-14 27-9-2 4-5-6 32-6-0 4-8-14 33-4-8 0-10-8 1-5-412-0-01-5-412-0-010.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [7:0-5-4,0-2-12], [12:0-3-0,0-1-12], [16:0-4-12,0-5-0], [17:0-4-12,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.65 0.63 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.30 0.03 0.11 (loc) 16-17 16-17 14 17-18 l/defl >999 >999 n/a >999 L/d 480 360 n/a 240 PLATES MT20 Weight: 290 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SP No.1 BOT CHORD 2x6 SP 2400F 2.0E *Except* 16-17: onCENTER® AFL 2.1E 1 1/2" x 11 7/8" WEBS 2x4 SPF-S Stud *Except* 4-17,9-16,5-8: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 9-9-10 oc bracing. WEBS 1 Row at midpt 24-25 JOINTS 1 Brace at Jt(s): 24, 25 REACTIONS.(lb/size) 19=1799/0-3-8, 14=1784/0-3-8 Max Horz 19=-233(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2109/0, 2-3=-2207/0, 3-4=-2194/0, 4-5=-1485/26, 5-6=-433/116, 6-7=-288/141, 7-8=-436/113, 8-9=-1494/26, 9-10=-2175/0, 10-11=-2188/0, 11-12=-1999/0, 1-19=-1727/0, 12-14=-1689/0 BOT CHORD 18-26=0/1574, 17-26=0/1580, 16-17=0/1610, 15-16=0/1488 WEBS 4-17=0/927, 9-16=0/882, 11-16=-147/348, 5-24=-1355/0, 24-25=-1362/0, 8-25=-1367/0, 2-18=-411/63, 11-15=-538/68, 1-18=0/1465, 12-15=0/1350 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Ceiling dead load (5.0 psf) on member(s). 4-5, 8-9, 5-24, 24-25, 8-25; Wall dead load (5.0psf) on member(s).4-17, 9-16 7) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 16-17 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Attic room checked for L/360 deflection. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE01 Truss Type Common Supported Gable Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548886 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:30 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-ADoH0qgYrUYQRNOxSiUfdlBYSPE2v6BM9wkIfxzh_lR Scale = 1:49.0 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-11-0 9-11-0 -0-10-8 0-10-8 4-11-8 4-11-8 9-11-0 4-11-8 10-11-0 1-0-0 1-5-45-6-131-5-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.16 0.07 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 11 11 12 11 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 61 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 9-11-0. (lb) - Max Horz 20=-139(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 15, 14 except 20=-138(LC 4), 12=-127(LC 5), 19=-127(LC 5), 13=-119(LC 4) Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 15, 14 except (jt=lb) 20=138, 12=127, 19=127, 13=119. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE02 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548887 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:31 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-fPMfDAhAcngH3Wz70P?u9ykfhpZgeXfVOaTsCNzh_lQ Scale = 1:111.0 12 3 4 56 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 3x4 3x4 3x6 4x6 3x6 3x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 27-1-8 27-1-8 13-6-12 13-6-12 27-1-8 13-6-12 28-0-0 0-10-8 1-5-412-8-141-5-410.00 12 Plate Offsets (X,Y)-- [37:0-1-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.39 0.18 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 0.01 0.00 (loc) 24 24 25 23 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 262 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 12-35,11-36,10-38,9-39,13-34,14-33,15-32: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 12-35, 11-36, 10-38, 9-39, 13-34, 14-33, 15-32 REACTIONS.All bearings 27-1-8. (lb) - Max Horz 46=-315(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 38, 39, 40, 41, 42, 43, 44, 33, 32, 31, 30, 29, 28, 27 except 46=-231(LC 4), 25=-215(LC 5), 45=-219(LC 5), 26=-222(LC 4) Max Grav All reactions 250 lb or less at joint(s) 36, 38, 39, 40, 41, 42, 43, 44, 45, 34, 33, 32, 31, 30, 29, 28, 27, 26 except 46=272(LC 5), 25=268(LC 4), 35=360(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-9=-28/263, 9-10=-30/307, 10-11=-30/360, 11-12=-32/364, 12-13=-30/364, 13-14=-29/360, 14-15=-29/307, 15-16=-27/263 WEBS 12-35=-386/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 38, 39, 40, 41, 42, 43, 44, 33, 32, 31, 30, 29, 28, 27 except (jt=lb) 46=231, 25=215, 45=219, 26=222. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE03 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548888 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:33 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-boUPesiQ7Pw?Iq7V7q1MFNpx8c776ISosuyyGGzh_lO Scale = 1:86.0 1 2 34 5 6 7 8 9 10 11 12 13 14 20 19 18 17 16 15 25 26 67 4x6 6x6 5x8 4x6 3x4 10x10 3x6 10x10 3x6 3x6 4x6 6x6 6x6 5x6 5x6 13-10-0 8-1-144-8-14 4-8-14 9-2-4 4-5-6 23-3-12 14-1-8 27-9-2 4-5-6 32-6-0 4-8-14 -0-10-8 0-10-8 4-8-14 4-8-14 9-2-4 4-5-6 9-5-2 0-2-14 10-1-11 0-8-9 12-8-2 2-6-7 19-9-14 7-1-13 22-4-5 2-6-7 23-0-14 0-8-9 23-3-12 0-2-14 27-9-2 4-5-6 32-6-0 4-8-14 33-4-8 0-10-8 1-5-412-0-01-5-412-0-010.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [8:0-5-4,0-2-12], [13:0-3-0,0-1-12], [17:0-4-12,0-5-0], [18:0-4-12,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.65 0.63 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.30 0.03 0.11 (loc) 17-18 17-18 15 18-19 l/defl >999 >999 n/a >999 L/d 480 360 n/a 240 PLATES MT20 Weight: 351 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SP No.1 BOT CHORD 2x6 SP 2400F 2.0E *Except* 17-18: onCENTER® AFL 2.1E 1 1/2" x 11 7/8" WEBS 2x4 SPF-S Stud *Except* 5-18,10-17,6-9: 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-3 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-8. BOT CHORD Rigid ceiling directly applied or 9-9-10 oc bracing. WEBS 1 Row at midpt 25-26 JOINTS 1 Brace at Jt(s): 25, 26 REACTIONS.(lb/size) 20=1849/0-3-8, 15=1783/0-3-8 Max Horz 20=-225(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2107/0, 3-4=-2203/0, 4-5=-2190/0, 5-6=-1484/26, 6-7=-433/116, 7-8=-287/141, 8-9=-436/113, 9-10=-1493/26, 10-11=-2174/0, 11-12=-2187/0, 12-13=-1998/0, 2-20=-1777/0, 13-15=-1689/0 BOT CHORD 19-67=0/1568, 18-67=0/1573, 17-18=0/1608, 16-17=0/1487 WEBS 5-18=0/923, 10-17=0/882, 12-17=-147/347, 6-25=-1355/0, 25-26=-1361/0, 9-26=-1365/0, 3-19=-409/62, 12-16=-537/68, 2-19=0/1447, 13-16=0/1350 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Ceiling dead load (5.0 psf) on member(s). 5-6, 9-10, 6-25, 25-26, 9-26; Wall dead load (5.0psf) on member(s).5-18, 10-17 10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 17-18 11) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Attic room checked for L/360 deflection. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE04 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548889 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:33 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-boUPesiQ7Pw?Iq7V7q1MFNpzQcDC6T1osuyyGGzh_lO Scale = 1:75.0 12 3 4 5 6 7 8 9 10 11 12 23 22 21 20 19 18 17 16 15 14 13 3x6 3x6 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-3-8 13-3-8 -0-10-8 0-10-8 6-7-12 6-7-12 13-3-8 6-7-12 3-0-88-6-153-0-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.57 0.24 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 -0.00 -0.00 0.00 (loc) 1 1 13 2 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 102 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-18 REACTIONS.All bearings 13-3-8. (lb) - Max Horz 23=235(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 19, 20, 21, 17, 16, 15 except 23=-294(LC 4), 13=-300(LC 5), 22=-337(LC 5), 14=-284(LC 4) Max Grav All reactions 250 lb or less at joint(s) 18, 19, 20, 21, 17, 16, 15 except 23=316(LC 5), 13=269(LC 4), 22=325(LC 4), 14=338(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 20, 21, 17, 16, 15 except (jt=lb) 23=294, 13=300, 22=337, 14=284. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE05 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548890 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:34 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-3_2nsCj2ui2sw_iihXYbnbM8U0ZWrw4y4YiWoizh_lN Scale = 1:75.0 12 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x6 3x6 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-3-8 13-3-8 -0-10-8 0-10-8 6-7-12 6-7-12 13-3-8 6-7-12 14-2-0 0-10-8 3-0-88-6-153-0-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.55 0.23 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 13 13 14 13 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 103 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-19 REACTIONS.All bearings 13-3-8. (lb) - Max Horz 24=225(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 21, 22, 17, 16 except 24=-307(LC 4), 14=-303(LC 5), 23=-311(LC 5), 15=-307(LC 4) Max Grav All reactions 250 lb or less at joint(s) 19, 20, 21, 22, 18, 17, 16 except 24=287(LC 5), 14=284(LC 4), 23=336(LC 4), 15=333(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-25/256, 6-7=-27/269, 7-8=-27/269, 8-9=-25/256 WEBS 7-19=-275/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 22, 17, 16 except (jt=lb) 24=307, 14=303, 23=311, 15=307. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE06 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548891 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:35 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-XBcA3Ykgf0AjY8HuFF3qKovJ8QvgaNb5JCR3L8zh_lM Scale = 1:77.5 12 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x6 3x6 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-0-0 14-0-0 -0-10-8 0-10-8 7-0-0 7-0-0 14-0-0 7-0-0 14-10-8 0-10-8 3-0-88-10-83-0-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.55 0.24 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 0.00 0.00 (loc) 13 13 14 12 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 113 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 7-19: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-19 REACTIONS.All bearings 14-0-0. (lb) - Max Horz 24=-232(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 20, 21, 22, 18, 17, 16 except 24=-262(LC 4), 14=-258(LC 5), 23=-282(LC 5), 15=-279(LC 4) Max Grav All reactions 250 lb or less at joint(s) 24, 14, 20, 21, 22, 18, 17, 16 except 19=255(LC 7), 23=313(LC 4), 15=310(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-26/264, 6-7=-26/285, 7-8=-26/285, 8-9=-26/264 WEBS 7-19=-305/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 22, 18, 17, 16 except (jt=lb) 24=262, 14=258, 23=282, 15=279. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE07 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548892 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:35 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-XBcA3Ykgf0AjY8HuFF3qKovHFQt8aNM5JCR3L8zh_lM Scale = 1:99.9 1 2 3 4 5 6 78 9 10 11 12 13 14 15 16 29 28 27 26 25 24 23 22 21 20 19 18 17 3x6 3x6 3x6 3x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-5-0 16-5-0 -0-10-8 0-10-8 12-8-2 12-8-2 16-5-0 3-8-14 1-5-412-0-010.00 12 Plate Offsets (X,Y)-- [13:0-3-0,0-0-4], [23:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.67 0.33 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 -0.00 0.00 0.00 (loc) 1 1 17 2 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 184 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 16-17: 2x4 SP No.1 OTHERS 2x4 SPF-S Stud *Except* 15-18,14-19,12-20,11-21,10-22: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 13-16. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 16-17, 15-18, 14-19, 12-20, 11-21, 10-22 REACTIONS.All bearings 16-5-0. (lb) - Max Horz 29=362(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27 except 29=-233(LC 4), 28=-362(LC 6) Max Grav All reactions 250 lb or less at joint(s) 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28 except 29=471(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-29=-331/174, 2-3=-410/230, 3-4=-274/167, 4-5=-271/177 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27 except (jt=lb) 29=233, 28=362. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE08 Truss Type PIGGYBACK BASE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548893 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:36 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-?N9YHtlIQKIa9Is4pya3s0RUIqEhJmpFYsBdtbzh_lL Scale = 1:92.6 1 2 3 4 5 11 10 9 8 7 612 13 14 4x6 4x6 5x6 3x4 3x6 3x6 3x6 3x4 4x8 2x4 3x8 6-6-12 6-6-12 12-1-2 5-6-6 16-8-14 4-7-13 22-5-0 5-8-2 6-6-12 6-6-12 12-1-2 5-6-6 16-8-14 4-7-13 22-5-0 5-8-2 1-11-112-0-07-3-412-0-010.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [3:0-6-4,0-2-0], [4:0-4-4,0-2-0], [5:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.53 0.31 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.11 0.01 0.02 (loc) 8-10 10-11 6 8-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 174 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.1 *Except* 2-10,1-11,1-10,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-14 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-8, 3-7, 4-7, 5-6 REACTIONS.(lb/size) 11=1002/Mechanical, 6=1087/Mechanical Max Horz 11=355(LC 5) Max Uplift11=-19(LC 6), 6=-37(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1052/114, 2-3=-786/204, 3-4=-394/191, 4-5=-614/186, 1-11=-947/91, 5-6=-962/108 BOT CHORD 10-11=-346/292, 9-10=-198/724, 9-12=-198/724, 8-12=-198/724, 8-13=-143/512, 7-13=-143/512 WEBS 2-8=-351/171, 3-8=-78/464, 3-7=-369/122, 1-10=0/673, 5-7=-80/611 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 6. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE09 Truss Type COMMON SUPPORTED GAB Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548894 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:37 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-TZjwUDlxBdQRnRQHMg6IPD_iTDc52GOOnWwAP1zh_lK Scale: 1/8"=1' 1 2 34 56 7 8 9 10 11 12 13 14 15 16 17 18 19 20 2122 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 3x8 2x4 3x6 4x6 3x4 3x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 22-8-0 22-8-0 -0-10-8 0-10-8 11-2-0 11-2-0 22-8-0 11-6-0 23-6-8 0-10-8 1-8-911-0-41-5-410.00 12 Plate Offsets (X,Y)-- [17:0-3-0,0-3-0], [34:0-3-0,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.37 0.17 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 0.01 0.00 (loc) 22 22 23 21 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 203 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 12-32,11-33,10-35,13-31,14-30: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 12-32, 11-33, 10-35, 13-31, 14-30 REACTIONS.All bearings 22-8-0. (lb) - Max Horz 41=-268(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 35, 36, 37, 38, 39, 31, 30, 29, 28, 27, 26, 25 except 41=-184(LC 4), 23=-345(LC 5), 40=-203(LC 5), 24=-318(LC 4) Max Grav All reactions 250 lb or less at joint(s) 41, 33, 35, 36, 37, 38, 39, 40, 31, 30, 29, 28, 27, 26, 25 except 23=389(LC 4), 32=322(LC 6), 24=293(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 9-10=-16/258, 10-11=-18/312, 11-12=-20/322, 12-13=-24/322, 13-14=-22/312, 14-15=-19/258 WEBS 12-32=-343/0, 3-41=-364/297 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 35, 36, 37, 38, 39, 31, 30, 29, 28, 27, 26, 25 except (jt=lb) 41=184, 23=345, 40=203, 24=318. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE10 Truss Type Monopitch Supported Gable Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548895 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:37 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-TZjwUDlxBdQRnRQHMg6IPD_faDb22GQOnWwAP1zh_lK Scale = 1:71.6 1 2 3 4 5 6 12 11 10 9 8 7 3x4 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-10-0 8-10-0 1-8-39-0-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.56 0.24 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 6-7: 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-7 REACTIONS.All bearings 8-10-0. (lb) - Max Horz 12=257(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 7, 8, 9, 10 except 12=-337(LC 4), 11=-458(LC 5) Max Grav All reactions 250 lb or less at joint(s) 7, 8, 9, 10 except 12=582(LC 5), 11=309(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-12=-336/192, 1-2=-351/204 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 8, 9, 10 except (jt=lb) 12=337, 11=458. 9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE11 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548896 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:38 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-xmHIhZmZyxZIPb?TwNdXyQXw2dyynj2X?AgjyTzh_lJ Scale = 1:37.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 25 24 23 22 21 20 19 18 17 16 15 3x6 2x4 2x4 3x6 3x4 3x6 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-3-0 16-3-0 -0-10-8 0-10-8 14-11-5 14-11-5 16-3-0 1-3-11 0-9-84-6-53-5-43.00 12 10.00 12 Plate Offsets (X,Y)-- [2:0-4-6,0-0-3], [7:0-2-8,0-1-8], [13:0-4-5,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.19 0.13 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.01 0.00 -0.00 (loc) 1 1 15 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 80 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 2-2-2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-3-0. (lb) - Max Horz 2=144(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 15, 2, 17, 18, 19, 21, 22, 23, 24, 25 Max Grav All reactions 250 lb or less at joint(s) 15, 2, 16, 17, 18, 19, 21, 22, 23, 24 except 25=347(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 2, 17, 18, 19, 21, 22, 23, 24, 25. 9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE12 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548897 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:38 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-xmHIhZmZyxZIPb?TwNdXyQXsvdybnk3X?AgjyTzh_lJ Scale = 1:60.9 1 2 3 4 5 6 7 13 12 11 10 9 8 3x4 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 -0-10-8 0-10-8 6-10-0 6-10-0 1-5-47-1-910.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.39 0.16 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 -0.00 0.00 -0.00 (loc) 1 1 8 2 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-10-0. (lb) - Max Horz 13=211(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 8, 9, 10 except 13=-137(LC 4), 12=-228(LC 6) Max Grav All reactions 250 lb or less at joint(s) 8, 9, 10, 11, 12 except 13=279(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 9, 10 except (jt=lb) 13=137, 12=228. 9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE13 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548898 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:39 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-QyrgvvnBjFh90lafU58mUe34V1IgWBIhEqPHUvzh_lI Scale = 1:16.4 1 2 3 4 2x4 2x4 2x4 -0-10-8 0-10-8 3-3-8 3-3-8 0-6-02-1-126.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.14 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.01 0.00 -0.00 (loc) 1 1 4 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 4=119/3-3-8, 2=186/3-3-8 Max Horz 2=59(LC 5) Max Uplift4=-14(LC 6), 2=-35(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE14 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548899 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:39 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-QyrgvvnBjFh90lafU58mUe33T1G0W92hEqPHUvzh_lI Scale = 1:71.3 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 103x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-3-11 11-3-11 0-0-49-5-210.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.21 0.21 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 9-10 REACTIONS.All bearings 11-3-11. (lb) - Max Horz 1=270(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17 Max Grav All reactions 250 lb or less at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-269/146 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss GE15 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548900 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:39 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-QyrgvvnBjFh90lafU58mUe33h1JNWBmhEqPHUvzh_lI Scale = 1:28.0 1 2 3 4 7 6 52x4 2x4 2x4 2x4 2x4 2x4 2x4 4-10-11 4-10-11 0-0-44-0-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.20 0.06 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 4-10-11. (lb) - Max Horz 1=109(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6, 7 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 7. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss M01 Truss Type MONOPITCH Qty 4 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548901 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:40 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-u8P36FopUYp0ev9s2of?1rcB6RbLFcuqTU9q0Mzh_lH Scale = 1:89.8 1 2 3 4 7 6 5 8 9 10 3x6 3x8 3x6 3x4 3x6 4x6 4x6 3x6 6-8-0 6-8-0 13-4-0 6-8-0 6-8-0 6-8-0 13-4-0 6-8-0 1-8-312-9-89-1-1212-9-810.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [4:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.41 0.27 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.11 0.24 0.02 (loc) 5-6 5-6 9 5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 94 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 4-5,3-5: 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-5 REACTIONS.(lb/size) 7=566/Mechanical, 9=565/0-3-0 Max Horz 7=328(LC 6) Max Uplift9=-213(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-557/0, 2-3=-331/0, 5-8=-121/438, 4-8=-121/438, 1-7=-515/0 BOT CHORD 6-7=-352/76, 6-10=-141/346, 5-10=-141/346 WEBS 3-6=0/257, 3-5=-486/199, 1-6=0/276, 4-9=-569/214 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=213. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss M02 Truss Type MONOPITCH Qty 3 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548902 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:40 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-u8P36FopUYp0ev9s2of?1rc89Rb9FcqqTU9q0Mzh_lH Scale = 1:89.8 1 2 3 4 5 8 7 6 9 10 11 3x6 3x8 3x6 3x4 3x6 4x6 5x6 3x6 6-9-12 6-9-12 13-7-8 6-9-12 -0-10-8 0-10-8 6-9-12 6-9-12 13-7-8 6-9-12 1-5-412-9-89-1-1212-9-810.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [5:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.60 0.28 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.11 0.26 0.02 (loc) 6-7 6-7 10 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 96 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 5-6,4-6: 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-8-12 oc bracing. WEBS 1 Row at midpt 4-6 REACTIONS.(lb/size) 8=642/0-3-8, 10=574/0-3-0 Max Horz 8=391(LC 6) Max Uplift10=-213(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-589/0, 3-4=-358/0, 6-9=-117/441, 5-9=-117/441, 2-8=-589/0 BOT CHORD 7-8=-417/127, 7-11=-144/362, 6-11=-144/362 WEBS 4-7=0/273, 4-6=-498/198, 2-7=0/281, 5-10=-578/214 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=213. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss M03 Truss Type Monopitch Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548903 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:41 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-MLzRKboRFsxtG3k2bWAEZ38HErwe_zy_h8uOYozh_lG Scale = 1:91.1 1 2 3 4 5 8 7 6 9 103x6 4x8 4x6 3x4 3x6 4x6 5x6 3x6 6-9-12 6-9-12 13-7-8 6-9-12 -0-10-8 0-10-8 6-9-12 6-9-12 13-7-8 6-9-12 1-5-412-9-86-3-49-1-126-6-410.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [5:0-4-8,Edge], [6:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.70 0.33 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.12 0.08 0.12 (loc) 7-8 7-8 10 7-8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 76 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-1-11 oc bracing. REACTIONS.(lb/size) 8=597/0-3-8, 10=507/0-3-0 Max Horz 8=502(LC 6) Max Uplift10=-348(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-897/699, 3-4=-667/726, 6-9=-581/386, 5-9=-581/386, 2-8=-604/452 BOT CHORD 7-8=-891/187, 6-7=-981/695 WEBS 4-7=-361/227, 4-6=-551/731, 2-7=-291/480, 5-10=-511/644 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 8, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=348. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss PB01 Truss Type Piggyback Qty 14 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548904 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:41 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-MLzRKboRFsxtG3k2bWAEZ38Q0r_J_5I_h8uOYozh_lG Scale = 1:24.8 1 2 3 4 5 6 4x6 2x4 2x4 2x4 7-1-13 7-1-13 3-6-14 3-6-14 7-1-13 3-6-14 0-4-132-11-120-1-80-4-130-1-810.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-1-0], [4:0-2-1,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.14 0.09 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.01 0.00 -0.00 (loc) 5 5 4 5 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=168/5-10-11, 4=168/5-10-11, 6=182/5-10-11 Max Horz 2=-59(LC 4) Max Uplift2=-35(LC 6), 4=-40(LC 7) Max Grav 2=168(LC 1), 4=168(LC 1), 6=183(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss PB02 Truss Type Piggyback Qty 17 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548905 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:41 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-MLzRKboRFsxtG3k2bWAEZ38SZr?G_5Y_h8uOYozh_lG Scale = 1:14.2 1 2 3 4 5 6 4x6 2x4 2x4 2x4 4-7-13 4-7-13 2-3-14 2-3-14 4-7-13 2-3-14 0-4-131-11-40-1-80-4-130-1-810.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-1-0], [4:0-2-1,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.04 0.03 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 4 5 4 4 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=108/3-4-11, 4=108/3-4-11, 6=102/3-4-11 Max Horz 2=-35(LC 4) Max Uplift2=-26(LC 6), 4=-30(LC 7) Max Grav 2=108(LC 1), 4=108(LC 1), 6=105(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss PBE01 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548906 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:42 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-qXXpXxp30A3ktDJE9DhT6GhdbELjiYf7woex5Ezh_lF Scale = 1:24.8 1 2 3 4 5 6 7 10 9 8 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 7-1-13 7-1-13 3-6-14 3-6-14 7-1-13 3-6-14 0-4-132-11-120-1-80-4-130-1-810.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-1-0], [6:0-2-1,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-7-3 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.03 0.02 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 6 6 6 6 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 27 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-10-11. (lb) - Max Horz 2=48(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 2, 6, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6, 10, 8. 9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss PBE02 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548907 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:42 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-qXXpXxp30A3ktDJE9DhT6GhdJELaiYq7woex5Ezh_lF Scale = 1:14.3 1 2 3 4 5 4x6 2x4 3x6 2x4 3-8-14 3-8-14 2-3-14 2-3-14 3-8-14 1-5-0 0-4-131-11-40-1-80-7-90-1-810.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.04 0.03 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 1 1 4 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 OTHERS 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=108/3-1-5, 4=73/3-1-5, 5=91/3-1-5 Max Horz 2=38(LC 5) Max Uplift2=-25(LC 6), 4=-13(LC 7) Max Grav 2=108(LC 1), 4=73(LC 1), 5=96(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss PBE03 Truss Type Piggyback Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548908 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:42 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-qXXpXxp30A3ktDJE9DhT6GhdJELViYo7woex5Ezh_lF Scale = 1:14.2 1 2 3 4 5 6 4x6 2x4 2x4 2x4 4-7-13 4-7-13 2-3-14 2-3-14 4-7-13 2-3-14 0-4-131-11-40-1-80-4-130-1-810.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-1-0], [4:0-2-1,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.04 0.03 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 4 5 4 4 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=108/3-4-11, 4=108/3-4-11, 6=102/3-4-11 Max Horz 2=-35(LC 4) Max Uplift2=-26(LC 6), 4=-30(LC 7) Max Grav 2=108(LC 1), 4=108(LC 1), 6=105(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T01 Truss Type Piggyback Base Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548909 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:43 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-Ij5BlHqhnTBaVMuQjwCieUEeGecBRvbH9RNUdhzh_lE Scale = 1:92.9 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 1121 3x6 5x8 4x8 3x6 3x4 2x4 2x4 2x4 3x4 4x8 3x6 5x12 5x12 3x12 3x6 4x6 5x6 5x6 6-9-12 6-9-12 13-2-8 6-4-12 14-5-8 1-3-0 16-11-14 2-6-6 22-6-4 5-6-6 29-8-0 7-1-12 -1-2-8 1-2-8 6-3-14 6-3-14 6-9-12 0-5-14 12-4-4 5-6-8 13-2-8 0-10-4 14-5-8 1-3-0 16-11-14 2-6-6 22-6-4 5-6-6 29-8-0 7-1-12 1-8-712-0-01-5-42-0-012-0-010.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [5:0-4-0,0-1-4], [7:0-6-4,0-2-0], [10:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.67 0.32 0.43 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.15 0.03 0.02 (loc) 11-12 11-12 11 12-13 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 240 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 5-15,7-15,7-13,8-13: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-14 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 14-15. 1 Row at midpt 5-16, 6-15 10-0-0 oc bracing: 16-18 WEBS 1 Row at midpt 4-19, 7-13, 8-13 REACTIONS.(lb/size) 20=343/0-3-8, 11=974/0-3-8, 19=1232/0-3-8 Max Horz 20=303(LC 5) Max Uplift20=-64(LC 7), 11=-46(LC 7), 19=-21(LC 6) Max Grav 20=353(LC 10), 11=974(LC 1), 19=1232(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-683/182, 5-6=-508/184, 6-7=-507/185, 7-8=-750/223, 8-9=-842/129, 9-10=-1084/99, 2-20=-294/127, 10-11=-912/107 BOT CHORD 19-20=-304/304, 15-16=-76/425, 13-21=0/739, 12-21=0/739 WEBS 4-19=-1081/80, 4-16=0/525, 5-15=-84/418, 13-15=-9/622, 8-13=-429/173, 10-12=0/613 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 11, 19. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T02 Truss Type COMMON Qty 5 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548910 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:44 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-mveZydrKYnJR7WTdHekxBhmof2tiALXQO57297zh_lD Scale = 1:102.2 1 2 3 4 5 6 7 8 13 12 11 10 914 15 16 17 18 19 3x6 4x6 3x6 3x6 3x6 4x6 3x6 4x6 3x8 4x6 4x6 3x8 9-1-11 9-1-11 17-11-13 8-10-3 27-1-8 9-1-11 6-11-2 6-11-2 13-6-12 6-7-10 20-2-6 6-7-10 27-1-8 6-11-2 28-0-0 0-10-8 1-5-412-8-141-5-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.76 0.69 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.35 0.04 0.02 (loc) 10-12 12-13 9 10-12 l/defl >999 >913 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 176 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.1 *Except* 5-10,3-12,1-13,7-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10, 4-12, 3-13, 5-9 REACTIONS.(lb/size) 13=1342/Mechanical, 9=1406/0-3-8 Max Horz 13=-315(LC 4) Max Uplift13=-34(LC 6), 9=-65(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-366/130, 3-4=-1431/277, 4-5=-1426/276, 6-7=-422/191, 1-13=-340/137, 7-9=-446/212 BOT CHORD 13-14=-67/1065, 14-15=-67/1065, 12-15=-67/1065, 12-16=0/759, 11-16=0/759, 11-17=0/759, 10-17=0/759, 10-18=0/1060, 18-19=0/1060, 9-19=0/1060 WEBS 4-10=-146/707, 5-10=-258/264, 4-12=-147/714, 3-12=-266/265, 3-13=-1242/0, 5-9=-1183/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T03 Truss Type COMMON Qty 3 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548911 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:44 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-mveZydrKYnJR7WTdHekxBhmoe2tjAMtQO57297zh_lD Scale = 1:102.2 1 2 3 4 5 6 7 8 9 14 13 12 11 1015 16 17 18 19 20 3x6 4x6 3x6 3x6 3x6 4x6 3x6 4x6 3x8 4x6 4x6 3x8 9-1-11 9-1-11 17-11-13 8-10-3 27-1-8 9-1-11 -0-10-8 0-10-8 6-11-2 6-11-2 13-6-12 6-7-10 20-2-6 6-7-10 27-1-8 6-11-2 28-0-0 0-10-8 1-5-412-8-141-5-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.76 0.69 0.43 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.18 -0.35 0.04 0.02 (loc) 11-13 13-14 10 11-13 l/defl >999 >915 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 178 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.1 *Except* 6-11,4-13,2-14,8-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-11, 5-13, 4-14, 6-10 REACTIONS.(lb/size) 14=1404/0-3-8, 10=1404/0-3-8 Max Horz 14=-304(LC 4) Max Uplift14=-66(LC 6), 10=-66(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-423/192, 4-5=-1424/277, 5-6=-1424/277, 7-8=-423/191, 2-14=-446/212, 8-10=-446/212 BOT CHORD 14-15=-67/1058, 15-16=-67/1058, 13-16=-67/1058, 13-17=0/758, 12-17=0/758, 12-18=0/758, 11-18=0/758, 11-19=0/1058, 19-20=0/1058, 10-20=0/1058 WEBS 5-11=-146/706, 6-11=-258/264, 5-13=-146/706, 4-13=-258/264, 4-14=-1181/0, 6-10=-1181/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T04 Truss Type Common Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548912 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:44 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-mveZydrKYnJR7WTdHekxBhmol2qAALBQO57297zh_lD Scale = 1:102.2 1 2 3 4 5 6 10 9 8 711 12 13 3x6 5x6 2x4 3x6 3x6 4x6 3x6 3x8 3x6 9-1-11 9-1-11 18-8-8 9-6-13 -0-10-8 0-10-8 6-11-2 6-11-2 13-6-12 6-7-10 18-8-8 5-1-12 1-5-412-8-148-5-710.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.75 0.85 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.33 -0.59 0.01 0.01 (loc) 7-9 7-9 7 9 l/defl >662 >377 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 138 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.1 *Except* 4-9,2-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-9, 4-10, 6-7, 5-7 REACTIONS.(lb/size) 10=967/0-3-8, 7=965/Mechanical Max Horz 10=311(LC 6) Max Uplift10=-10(LC 6), 7=-102(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-371/195, 4-5=-854/171, 2-10=-411/214 BOT CHORD 10-11=-171/639, 11-12=-171/639, 9-12=-171/639, 8-9=-38/274, 8-13=-38/274, 7-13=-38/274 WEBS 4-9=-304/273, 5-9=-138/819, 4-10=-636/0, 5-7=-676/107 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10 except (jt=lb) 7=102. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T05 Truss Type COMMON Qty 6 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548913 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:45 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-E6Cy9ysyJ5RIkg2pqLFAkvJ_YSJivu3ZclsbhZzh_lC Scale = 1:65.9 1 2 3 4 7 6 5 4x6 5x6 2x4 2x4 3x8 5x6 6-7-12 6-7-12 13-3-8 6-7-12 -0-10-8 0-10-8 6-7-12 6-7-12 13-3-8 6-7-12 3-0-88-6-153-0-810.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [4:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.68 0.26 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.09 -0.00 0.00 (loc) 5-6 5-6 5 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 74 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-6 REACTIONS.(lb/size) 7=584/0-3-8, 5=518/0-3-8 Max Horz 7=235(LC 5) Max Uplift7=-34(LC 6), 5=-26(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-426/113, 3-4=-421/109, 2-7=-526/101, 4-5=-460/78 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T06 Truss Type Common Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548914 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:45 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-E6Cy9ysyJ5RIkg2pqLFAkvJ_VSIJvuAZclsbhZzh_lC Scale = 1:65.9 1 2 3 45 8 7 6 4x6 2x4 2x4 3x8 5x6 5x6 6-7-12 6-7-12 13-3-8 6-7-12 -0-10-8 0-10-8 6-7-12 6-7-12 13-3-8 6-7-12 14-2-0 0-10-8 3-0-88-6-153-0-810.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [4:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.69 0.28 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.09 0.00 0.00 (loc) 6-7 6-7 6 7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 76 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.(lb/size) 8=581/0-3-8, 6=581/0-3-8 Max Horz 8=225(LC 5) Max Uplift8=-37(LC 6), 6=-37(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-423/119, 3-4=-423/119, 2-8=-524/107, 4-6=-524/107 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T07 Truss Type COMMON Qty 4 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548915 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:46 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-iImKNIsa4OZ9Mqc?O3mPG6sGPseAeG_jrPc9E?zh_lB Scale = 1:68.1 1 2 3 4 5 6 7 10 9 8 4x6 3x8 3x4 3x4 2x4 3x4 2x4 3x4 7-0-0 7-0-0 14-0-0 7-0-0 -0-10-8 0-10-8 3-0-0 3-0-0 7-0-0 4-0-0 11-0-0 4-0-0 14-0-0 3-0-0 14-10-8 0-10-8 3-0-88-10-83-0-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.23 0.30 0.39 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.11 0.01 0.00 (loc) 9-10 9-10 8 9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 92 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 4-9: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 10=610/0-3-8, 8=610/0-3-8 Max Horz 10=-232(LC 4) Max Uplift10=-38(LC 6), 8=-38(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-386/146, 4-5=-386/146 WEBS 3-10=-464/6, 5-8=-464/6 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 8. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T09 Truss Type Common Qty 3 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548916 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:46 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-iImKNIsa4OZ9Mqc?O3mPG6sGOsdieGsjrPc9E?zh_lB Scale = 1:68.1 1 2 3 4 5 8 7 6 2x4 4x6 2x4 3x8 3x4 3x4 3x4 3x4 7-0-0 7-0-0 14-0-0 7-0-0 3-0-0 3-0-0 7-0-0 4-0-0 11-0-0 4-0-0 14-0-0 3-0-0 3-0-88-10-83-0-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.23 0.33 0.40 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.11 0.01 0.00 (loc) 7-8 7-8 6 7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 3-7: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 8=548/0-3-8, 6=548/0-3-8 Max Horz 8=-229(LC 4) Max Uplift8=-21(LC 7), 6=-21(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-392/135, 3-4=-392/135 WEBS 2-8=-474/19, 4-6=-474/19 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T10 Truss Type PIGGYBACK BASE Qty 6 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548917 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:47 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-BUKiaetCqih0__BCymHepKOL1FzCNjts43LimSzh_lA Scale = 1:94.0 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 1017 18 19 3x6 4x8 4x6 3x6 3x4 3x6 3x6 4x6 3x4 3x8 3x6 4x6 5x6 3x4 5x6 6-9-12 6-9-12 12-4-2 5-6-6 16-11-14 4-7-13 22-6-4 5-6-6 29-8-0 7-1-12 -1-2-8 1-2-8 6-9-12 6-9-12 12-4-2 5-6-6 16-11-14 4-7-13 22-6-4 5-6-6 29-8-0 7-1-12 1-8-912-0-01-5-412-0-010.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [5:0-6-4,0-2-0], [6:0-4-4,0-2-0], [9:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.62 0.38 0.41 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.15 0.02 0.01 (loc) 10-11 10-11 10 11-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 209 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 4-14,5-14,5-12,6-12,7-12: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-15 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-15, 5-14, 7-12 REACTIONS.(lb/size) 16=462/0-3-8, 15=1242/0-3-8, 10=1046/0-3-8 Max Horz 16=302(LC 5) Max Uplift16=-40(LC 6), 15=-44(LC 6), 10=-37(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-316/64, 4-5=-712/206, 5-6=-557/206, 6-7=-851/217, 7-8=-935/123, 8-9=-1177/93, 2-16=-408/105, 9-10=-984/103 BOT CHORD 15-16=-304/304, 13-14=-77/448, 13-18=-77/448, 12-18=-77/448, 12-19=0/810, 11-19=0/810 WEBS 4-15=-1031/125, 4-14=-7/486, 5-12=-74/349, 7-12=-413/174, 9-11=0/682 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 15, 10. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T11 Truss Type PIGGYBACK BASE Qty 3 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548918 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:47 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-BUKiaetCqih0__BCymHepKOMvFz5Nj7s43LimSzh_lA Scale = 1:94.0 1 2 3 4 5 6 7 8 15 14 13 12 11 10 916 17 18 3x6 4x8 4x6 4x6 3x4 3x6 3x6 4x6 3x4 3x8 3x6 3x6 5x6 3x4 6-9-12 6-9-12 12-4-2 5-6-6 16-11-14 4-7-13 22-6-4 5-6-6 29-1-0 6-6-12 -1-2-8 1-2-8 6-9-12 6-9-12 12-4-2 5-6-6 16-11-14 4-7-13 22-6-4 5-6-6 29-1-0 6-6-12 1-8-912-0-01-11-112-0-010.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [5:0-6-4,0-2-0], [6:0-4-4,0-2-0], [8:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.56 0.32 0.39 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.11 0.01 0.01 (loc) 10-11 9-10 9 10-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 207 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 4-13,5-13,5-11,6-11,7-11: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-13 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-14, 5-13, 7-11 REACTIONS.(lb/size) 15=474/0-3-8, 14=1201/0-3-8, 9=1030/Mechanical Max Horz 15=308(LC 5) Max Uplift15=-38(LC 6), 14=-46(LC 6), 9=-34(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-330/61, 4-5=-701/205, 5-6=-537/205, 6-7=-823/213, 7-8=-1084/122, 2-15=-419/105, 8-9=-975/97 BOT CHORD 14-15=-309/303, 12-13=-84/440, 12-17=-84/440, 11-17=-84/440, 11-18=0/748, 10-18=0/748 WEBS 4-14=-992/124, 4-13=-10/457, 5-11=-77/320, 7-11=-347/168, 8-10=0/698 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 14, 9. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T12 Truss Type PIGGYBACK BASE Qty 7 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548919 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:48 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-fhu4o_uqb0ptc8mOWUotLXxY4fKy6Bn0Ij5FIuzh_l9 Scale = 1:92.6 1 2 3 4 5 11 10 9 8 7 612 13 14 4x6 4x6 5x6 3x4 3x6 3x6 3x6 3x4 4x8 2x4 3x8 6-6-12 6-6-12 12-1-2 5-6-6 16-8-14 4-7-13 22-5-0 5-8-2 6-6-12 6-6-12 12-1-2 5-6-6 16-8-14 4-7-13 22-5-0 5-8-2 1-11-112-0-07-3-412-0-010.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [3:0-6-4,0-2-0], [4:0-4-4,0-2-0], [5:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.47 0.28 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.11 0.01 0.02 (loc) 8-10 10-11 6 8-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 174 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.1 *Except* 2-10,1-11,1-10,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-14 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-8, 3-7, 4-7, 5-6 REACTIONS.(lb/size) 11=1002/Mechanical, 6=1087/Mechanical Max Horz 11=355(LC 5) Max Uplift11=-19(LC 6), 6=-37(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1052/114, 2-3=-786/204, 3-4=-394/191, 4-5=-614/186, 1-11=-947/91, 5-6=-962/108 BOT CHORD 10-11=-346/292, 9-10=-198/724, 9-12=-198/724, 8-12=-198/724, 8-13=-143/512, 7-13=-143/512 WEBS 2-8=-351/171, 3-8=-78/464, 3-7=-369/122, 1-10=0/673, 5-7=-80/611 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 6. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T13 Truss Type ROOF SPECIAL Qty 8 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548920 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:48 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-fhu4o_uqb0ptc8mOWUotLXxZ2fHG69m0Ij5FIuzh_l9 Scale = 1:35.6 1 2 3 4 5 6 7 11 10 9 8 3x6 4x6 4x8 3x4 3x6 3x6 2x4 2x4 4x8 4x6 7-0-0 7-0-0 14-11-5 7-11-5 16-3-0 1-3-11 -0-10-8 0-10-8 7-0-0 7-0-0 14-11-5 7-11-5 16-3-0 1-3-11 0-9-84-6-53-5-43.00 12 10.00 12 Plate Offsets (X,Y)-- [2:0-5-14,Edge], [6:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix-S) 0.41 0.46 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.08 -0.24 0.03 0.05 (loc) 9-11 9-11 8 9-11 l/defl >999 >815 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 73 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 2-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-9 REACTIONS.(lb/size) 2=698/0-3-8, 8=643/0-3-8 Max Horz 2=142(LC 5) Max Uplift2=-76(LC 6), 8=-51(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-355/0, 3-4=-1252/187, 4-5=-318/52, 5-6=-260/69, 7-8=-709/62 BOT CHORD 2-11=-153/1247, 10-11=-153/1247, 9-10=-153/1247 WEBS 4-11=0/277, 4-9=-1036/189, 7-9=-47/686 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss design requires that a minimum of 7/16” structural wood sheathing be applied directly to the top chord and ½” gypsum sheetrock be applied directly to the bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss T14 Truss Type ROOF SPECIAL Qty 10 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548921 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:49 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-7tSS?KvSMJxkDHLa3BJ6ulUiy3d2rbZ9XNqpqKzh_l8 Scale = 1:106.2 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 3x6 4x6 4x6 3x4 8x8 2x4 3x4 3x6 3x6 4x6 4x10 3x6 2x4 5x6 3x6 6-4-0 6-4-0 12-4-8 6-0-8 12-6-4 0-1-12 20-9-4 8-3-0 26-0-0 5-2-12 32-11-8 6-11-8 -0-10-8 0-10-8 6-4-0 6-4-0 12-4-8 6-0-8 14-8-2 2-3-10 20-9-4 6-1-2 26-0-0 5-2-12 32-11-8 6-11-8 33-10-0 0-10-8 1-5-48-7-213-8-10-6-02-0-04-0-84-0-810.00 12 6.00 12 6.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [9:0-0-0,0-0-5], [13:0-4-8,0-2-0], [15:0-2-12,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.53 0.49 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.13 -0.34 -0.03 0.08 (loc) 13-14 13-14 14 16-17 l/defl >999 >719 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 200 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 13-15,6-13: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 5-3-4 oc bracing. WEBS 1 Row at midpt 13-15, 6-15, 6-13 REACTIONS.(lb/size) 17=459/0-3-8, 14=1459/0-3-8, 9=816/0-5-8 Max Horz 17=348(LC 5) Max Uplift17=-132(LC 7), 14=-236(LC 6), 9=-104(LC 7) Max Grav 17=473(LC 10), 14=1459(LC 1), 9=832(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-605/566, 4-5=-133/360, 5-6=-25/292, 6-7=-866/315, 7-8=-723/135, 8-9=-1206/129, 2-17=-474/376 BOT CHORD 16-17=-457/239, 15-16=-457/446, 14-15=-1382/614, 5-15=-280/172, 12-13=-30/983, 11-12=-30/983, 9-11=-30/983 WEBS 3-16=-356/245, 3-15=-543/676, 13-15=-31/296, 6-15=-892/267, 6-13=-388/1031, 7-13=-506/233, 8-13=-502/139, 2-16=-194/276 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 17=132, 14=236, 9=104. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548922 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:49 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-7tSS?KvSMJxkDHLa3BJ6ulUcC3blrXx9XNqpqKzh_l8 Scale = 1:45.2 1 2 3 6 5 47 8 9 10 3x8 4x6 3x8 3x6 3x6 10x10 4-11-8 4-11-8 9-11-0 4-11-8 4-11-8 4-11-8 9-11-0 4-11-8 1-5-45-6-131-5-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.90 0.63 0.82 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.04 -0.08 0.00 0.02 (loc) 4-5 4-5 4 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 117 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6=2972/0-3-8, 4=3086/0-3-8 Max Horz 6=-132(LC 3) Max Uplift6=-102(LC 6), 4=-106(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2647/135, 2-3=-2648/135, 1-6=-2167/98, 3-4=-2163/98 BOT CHORD 6-7=-148/340, 7-8=-148/340, 5-8=-148/340, 5-9=-36/360, 9-10=-36/360, 4-10=-36/360 WEBS 2-5=-64/3004, 1-5=-82/1670, 3-5=-83/1649 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=102, 4=106. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1322 lb down and 46 lb up at 2-0-12, 1322 lb down and 46 lb up at 4-0-12, and 1322 lb down and 46 lb up at 6-0-12, and 1322 lb down and 46 lb up at 8-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-6=-20 Concentrated Loads (lb) Vert: 7=-1322(B) 8=-1322(B) 9=-1322(B) 10=-1322(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548923 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:50 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-b30rDgv47d3brRwndvqLRy0mKTtIa3UIm1aMNnzh_l7 Scale = 1:102.2 1 2 3 4 5 6 7 8 13 12 11 10 914 15 16 17 18 19 2021 22 3x6 4x6 3x6 4x8 6x6 4x6 6x6 4x6 3x4 6x8 6x8 3x4 9-1-11 9-1-11 17-11-13 8-10-3 27-1-8 9-1-11 -0-10-8 0-10-8 6-11-2 6-11-2 13-6-12 6-7-10 20-2-6 6-7-10 27-1-8 6-11-2 1-5-412-8-141-5-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 1.00 0.87 0.48 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.47 0.02 0.02 (loc) 9-10 9-10 9 9-10 l/defl >999 >682 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 397 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SP No.1 *Except* 6-10,4-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 13=1836/0-3-8, 9=3658/0-3-8 Max Horz 13=312(LC 4) Max Uplift13=-24(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-583/189, 3-4=-350/217, 4-5=-1973/182, 5-6=-2788/81, 6-7=-1056/0, 7-8=-1289/0, 2-13=-552/211, 8-9=-935/14 BOT CHORD 13-14=-39/1469, 14-15=-39/1469, 12-15=-39/1469, 12-16=0/1272, 11-16=0/1272, 11-17=0/1272, 10-17=0/1272, 10-18=0/2096, 18-19=0/2096, 19-20=0/2096, 20-21=0/2096, 21-22=0/2096, 9-22=0/2096 WEBS 5-10=0/2281, 6-10=-218/275, 5-12=-217/429, 4-12=-217/274, 4-13=-1586/0, 6-9=-1695/37 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 639 lb down and 87 lb up at 18-10-0, 506 lb down at 20-9-4, 522 lb down at 22-9-4, and 546 lb down at 24-9-4, and 554 lb down at 26-11-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-5=-60, 5-8=-60, 13-14=-20, 14-15=-60, 15-16=-20, 16-17=-60, 17-19=-20, 19-21=-60, 9-21=-20 Concentrated Loads (lb) Vert: 9=-554(F) 18=-639(F) 20=-506(F) 21=-522(F) 22=-546(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss TG03 Truss Type GABLE Qty 1 Ply 2 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548924 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:52 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-XS7bdMxLfEJJ4l49lJtpWN6BeGXc2vIbDL3TRfzh_l5 Scale = 1:136.2 1 2 3 4 5 11 10 9 8 7 639 40 41 4243 4445 4647 4849 6x6 4x6 5x8 3x4 5x6 8x10 10x10 3x8 10x10 3x8 4x8 2x4 2x4 2x4 4x6 2x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2-3-10 2-3-10 8-4-12 6-1-2 14-4-2 5-11-6 20-7-0 6-2-14 2-3-10 2-3-10 8-4-12 6-1-2 14-4-2 5-11-6 20-7-0 6-2-14 11-9-08-7-213-8-12-6-010.00 12 6.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [7:0-3-8,0-5-0], [8:0-2-6,0-2-8], [9:0-3-8,0-5-0], [15:0-0-7,0-2-0], [18:0-1-8,0-1-0], [28:0-1-5,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.69 0.94 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.12 -0.27 0.03 0.07 (loc) 9-10 9-10 6 9-10 l/defl >999 >895 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 439 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud *Except* 2-10,3-10,3-9,1-10,5-6,5-7: 2x4 SP No.1, 1-11: 2x4 SP 2400F 2.0E OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-10, 1-11 REACTIONS.(lb/size) 11=5941/0-3-8, 6=6563/0-5-8 Max Horz 11=-454(LC 3) Max Uplift11=-305(LC 6), 6=-197(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1251/205, 2-3=-1343/187, 3-4=-4293/183, 4-5=-5861/205, 1-11=-5770/352, 5-6=-4499/166 BOT CHORD 11-39=-125/368, 10-39=-125/368, 10-40=-111/3690, 40-41=-111/3690, 41-42=-111/3690, 9-42=-111/3690, 9-43=-116/5171, 8-43=-116/5171, 8-44=-116/5171, 44-45=-116/5171, 7-45=-116/5171, 7-46=-21/322, 46-47=-21/322, 47-48=-21/322, 48-49=-21/322, 6-49=-21/322 WEBS 2-10=-288/1355, 3-10=-4605/306, 3-9=-137/4432, 4-9=-1889/158, 4-7=-51/1722, 1-10=-298/5033, 5-7=-101/5150 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 6) Vertical gable studs spaced at 1-4-0 oc and horizontal gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=305, 6=197. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1007 lb down and 44 lb up at 1-0-4, 1005 lb down and 45 lb up at 3-0-4, 1005 lb down and 45 lb up at 5-0-4, 982 lb down and 31 lb up at 7-0-4, 982 lb down and 31 lb up at 9-0-4, 982 lb down and 31 lb up at 11-0-4, 982 lb down and 31 lb up at 13-0-4, 982 lb down and 31 lb up at 15-0-4, 982 lb down and 31 lb up at 17-0-4, and 982 lb down and 31 lb up at 19-0-4, and 987 lb down and 29 lb up at 19-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss TG03 Truss Type GABLE Qty 1 Ply 2 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548924 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:52 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-XS7bdMxLfEJJ4l49lJtpWN6BeGXc2vIbDL3TRfzh_l5 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-5=-60, 6-11=-20 Concentrated Loads (lb) Vert: 39=-1007(B) 40=-1005(B) 41=-1005(B) 42=-982(B) 43=-982(B) 44=-982(B) 45=-982(B) 46=-982(B) 47=-982(B) 48=-982(B) 49=-987(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B18800879 Truss TG04 Truss Type Common Girder Qty 1 Ply 2 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548925 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:52 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-XS7bdMxLfEJJ4l49lJtpWN691Gay2yabDL3TRfzh_l5 Scale = 1:68.1 1 2 3 4 5 8 7 69 10 11 12 13 14 3x4 4x6 3x4 10x10 3x6 3x6 4x8 4x8 7-0-0 7-0-0 14-0-0 7-0-0 3-0-0 3-0-0 7-0-0 4-0-0 11-0-0 4-0-0 14-0-0 3-0-0 3-0-88-10-83-0-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.80 0.73 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.20 0.01 0.05 (loc) 6-7 6-7 6 6-7 l/defl >999 >835 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 199 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-7: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 8=4315/0-3-8, 6=4256/0-3-8 Max Horz 8=226(LC 4) Max Uplift8=-193(LC 6), 6=-191(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-254/79, 2-3=-2757/218, 3-4=-2757/218, 4-5=-258/79 BOT CHORD 8-9=-182/1503, 9-10=-182/1503, 10-11=-182/1503, 7-11=-182/1503, 7-12=-69/1503, 12-13=-69/1503, 13-14=-69/1503, 6-14=-69/1503 WEBS 3-7=-193/3189, 4-7=-91/968, 2-7=-91/968, 2-8=-2834/123, 4-6=-2831/123 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=193, 6=191. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1069 lb down and 48 lb up at 0-11-4, 1067 lb down and 49 lb up at 2-11-4, 1067 lb down and 49 lb up at 4-11-4, 1067 lb down and 49 lb up at 6-11-4, 1067 lb down and 49 lb up at 8-11-4, and 1067 lb down and 49 lb up at 10-11-4, and 1068 lb down and 49 lb up at 12-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-8=-20 Concentrated Loads (lb) Vert: 7=-1067(B) 9=-1069(B) 10=-1067(B) 11=-1067(B) 12=-1067(B) 13=-1067(B) 14=-1068(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss TG05 Truss Type Flat Girder Qty 1 Ply 2 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548926 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:53 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-?ehzrhyzQYRAivfMI1O22beVNg_NnXmlS?o0z5zh_l4 Scale = 1:53.81 2 4 35 2x4 3x4 2x4 4x6 4-0-0 4-0-0 4-0-0 4-0-0 8-2-15LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.12 0.46 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.02 -0.03 -0.00 0.01 (loc) 3-4 3-4 3 3-4 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 84 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud *Except* 1-3: 2x4 SP No.1 BRACING- TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 4=668/Mechanical, 3=573/0-3-8 Max Uplift4=-75(LC 3), 3=-64(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 945 lb down and 114 lb up at 1-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 3-4=-20 Concentrated Loads (lb) Vert: 5=-945(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V01 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548927 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:53 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-?ehzrhyzQYRAivfMI1O22beUwg3AnUulS?o0z5zh_l4 Scale = 1:70.1 1 2 3 4 7 6 583x4 2x4 2x4 2x4 2x4 2x4 2x4 11-10-5 11-10-5 0-0-49-10-1010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.15 0.15 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 62 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS.All bearings 11-10-0. (lb) - Max Horz 1=291(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 5 except 6=-120(LC 6), 7=-116(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=520(LC 1), 7=360(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-340/74 WEBS 3-6=-258/174 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 6=120 , 7=116. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V02 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548928 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:53 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-?ehzrhyzQYRAivfMI1O22beROg2?nTclS?o0z5zh_l4 Scale = 1:78.7 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9163x4 4x6 4x6 3x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 18-3-1 18-3-1 28-4-8 10-1-7 12-1-15 12-1-15 18-3-1 6-1-2 28-4-8 10-1-7 0-0-45-0-1210-1-100-0-410.00 12 6.00 12 Plate Offsets (X,Y)-- [12:0-3-0,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.37 0.23 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 129 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 4-13: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-13 REACTIONS.All bearings 28-4-8. (lb) - Max Horz 1=-235(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 10 except 14=-121(LC 6), 15=-121(LC 6), 11=-108(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 8, 10 except 13=413(LC 1), 14=497(LC 10), 15=393(LC 1), 11=380(LC 11), 9=474(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-14=-256/169, 2-15=-251/166, 7-9=-345/171 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 10 except (jt=lb) 14=121, 15=121, 11=108. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V03 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548929 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:54 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-TrFL21ybBsa1K3EYskvHboBaY4NeWxDuhfYaWYzh_l3 Scale = 1:69.0 1 2 3 4 5 6 7 8 15 14 13 12 11 10 93x4 4x6 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 16-3-1 16-2-12 23-0-8 6-9-7 10-1-15 10-1-15 16-3-1 6-1-2 23-0-8 6-9-7 0-0-43-4-128-5-100-0-410.00 12 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.47 0.27 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 *Except* 6-8: 2x4 SPF-S Stud BOT CHORD 2x4 SP No.1 *Except* 1-13: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-11-11. (lb) - Max Horz 1=-194(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 15, 9, 10 except 14=-128(LC 6), 11=-110(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 8, 10 except 12=410(LC 1), 14=423(LC 10), 15=254(LC 1), 11=398(LC 11), 9=363(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-14=-267/176, 7-9=-250/124 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 15, 9, 10 except (jt=lb) 14=128, 11=110. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V04 Truss Type GABLE Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548930 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:54 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-TrFL21ybBsa1K3EYskvHboBfH4O2WyfuhfYaWYzh_l3 Scale = 1:53.2 1 2 3 4 5 6 11 10 9 8 712133x4 4x6 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 14-3-1 14-3-1 17-8-8 3-5-7 8-1-15 8-1-15 14-3-1 6-1-2 17-8-8 3-5-7 0-0-41-8-126-9-100-0-410.00 12 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.17 0.24 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 65 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 *Except* 5-6: 2x4 SPF-S Stud BOT CHORD 2x4 SP No.1 *Except* 6-9: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-8-8. (lb) - Max Horz 1=-153(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7 except 11=-134(LC 6), 8=-109(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 6, 7 except 10=402(LC 1), 11=409(LC 10), 8=334(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-11=-273/179 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7 except (jt=lb) 11=134, 8=109. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V05 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548931 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:55 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-y1pkGNzDy9itxCokQSQW80klGUmbFQo2vJH72_zh_l2 Scale = 1:40.8 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-5 0-0-5 12-3-15 12-3-10 6-1-15 6-1-15 12-3-15 6-1-15 0-0-45-1-100-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.41 0.09 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-3-5. (lb) - Max Horz 1=112(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-112(LC 6), 6=-111(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=296(LC 10), 6=296(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=112, 6=111. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V06 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548932 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:55 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-y1pkGNzDy9itxCokQSQW80knWUleFRO2vJH72_zh_l2 Scale = 1:29.3 1 2 3 43x6 4x6 3x6 2x4 0-0-5 0-0-5 8-3-15 8-3-10 4-1-15 4-1-15 8-3-15 4-1-15 0-0-43-5-100-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.27 0.15 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=159/8-3-5, 3=159/8-3-5, 4=283/8-3-5 Max Horz 1=-73(LC 4) Max Uplift1=-15(LC 6), 3=-19(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V07 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548933 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:55 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-y1pkGNzDy9itxCokQSQW80kqqUmrFRx2vJH72_zh_l2 Scale = 1:14.1 1 2 3 4 2x4 4x6 2x4 2x4 4-3-10 4-3-10 4-3-15 0-0-5 2-1-15 2-1-15 4-3-15 2-1-15 0-0-41-9-100-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.12 0.08 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=80/4-3-5, 3=80/4-3-5, 4=122/4-3-5 Max Horz 1=-34(LC 4) Max Uplift1=-12(LC 7), 3=-14(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V08 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548934 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:56 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-QDN6Tj_rjTqkZMNw_9xlgDGs6u28_oLB8z1gaQzh_l1 Scale = 1:90.0 1 2 3 4 5 6 7 13 12 11 10 9 8 3x6 4x6 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 18-5-13 18-5-13 13-4-1 13-4-1 18-5-13 5-1-12 0-0-411-1-66-9-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.66 0.33 0.33 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 3-5: 2x4 SP No.1 BOT CHORD 2x4 SP No.1 *Except* 8-11: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 5-10: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-10 REACTIONS.All bearings 18-5-8. (lb) - Max Horz 1=243(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-101(LC 11), 12=-112(LC 6), 13=-148(LC 6), 9=-112(LC 7) Max Grav All reactions 250 lb or less at joint(s) 8, 1 except 10=472(LC 1), 12=482(LC 10), 13=492(LC 1), 9=426(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-270/164 WEBS 2-13=-299/197 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=101 , 12=112, 13=148, 9=112. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V09 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548935 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:56 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-QDN6Tj_rjTqkZMNw_9xlgDGwau2A_q2B8z1gaQzh_l1 Scale = 1:76.8 1 2 3 4 5 6 12 11 10 9 8 7133x4 4x6 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-5-13 16-5-13 11-4-1 11-4-1 16-5-13 5-1-12 0-0-49-5-65-1-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.44 0.33 0.22 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 79 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 *Except* 4-6: 2x4 SPF-S Stud BOT CHORD 2x4 SP No.1 *Except* 7-10: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 4-9: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-9 REACTIONS.All bearings 16-5-8. (lb) - Max Horz 1=272(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 9 except 7=-104(LC 11), 11=-125(LC 6), 12=-107(LC 6), 8=-121(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1 except 9=468(LC 1), 11=501(LC 10), 12=324(LC 1), 8=429(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-287/213 WEBS 3-11=-264/174 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9 except (jt=lb) 7=104, 11=125, 12=107, 8=121. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V10 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548936 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:57 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-uQxUh3?UUnybBWy7XtT_DRp43HRYjGKKNdmE7tzh_l0 Scale = 1:60.6 1 2 3 4 5 9 8 7 63x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-5-13 14-5-13 9-4-1 9-4-1 14-5-13 5-1-12 0-0-47-9-63-5-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.46 0.19 0.28 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 *Except* 3-5: 2x4 SPF-S Stud BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-5-8. (lb) - Max Horz 1=213(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 8 except 6=-105(LC 11), 9=-157(LC 6), 7=-127(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=454(LC 1), 9=509(LC 10), 7=430(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-320/208 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8 except (jt=lb) 6=105, 9=157, 7=127. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V11 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548937 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:57 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-uQxUh3?UUnybBWy7XtT_DRp4?HSajIwKNdmE7tzh_l0 Scale: 1/4"=1' 1 2 3 4 5 9 8 7 610 113x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 12-5-13 12-5-13 7-4-1 7-4-1 12-5-13 5-1-12 0-0-46-1-61-9-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.46 0.12 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 50 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 *Except* 3-5: 2x4 SPF-S Stud BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-5-8. (lb) - Max Horz 1=154(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 6 except 9=-122(LC 6), 7=-138(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=448(LC 1), 9=353(LC 10), 7=349(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-250/164 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6 except (jt=lb) 9=122, 7=138. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V12 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548938 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:57 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-uQxUh3?UUnybBWy7XtT_DRp4_HPNjJBKNdmE7tzh_l0 Scale = 1:35.2 1 2 3 43x6 4x6 3x6 2x4 0-0-5 0-0-5 10-5-13 10-5-8 5-4-1 5-4-1 10-5-13 5-1-12 0-0-44-5-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.46 0.26 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=209/10-7-9, 3=209/10-7-9, 4=372/10-7-9 Max Horz 1=96(LC 5) Max Uplift1=-19(LC 6), 3=-24(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V13 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548939 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:58 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-McVsuP06F44SogXJ5a_DleMKIhmASnOUcHWnfJzh_l? Scale = 1:24.3 1 2 3 43x4 4x6 3x4 2x4 0-0-5 0-0-5 6-8-2 6-7-13 3-4-1 3-4-1 6-8-2 3-4-1 0-0-42-9-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.17 0.16 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=123/6-7-9, 3=123/6-7-9, 4=224/6-7-9 Max Horz 1=-57(LC 4) Max Uplift1=-13(LC 7), 3=-17(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V14 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548940 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:58 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-McVsuP06F44SogXJ5a_DleMMPhnMSn?UcHWnfJzh_l? Scale = 1:10.0 1 2 3 2x4 3x4 2x4 2-7-13 2-7-13 2-8-2 0-0-5 1-4-1 1-4-1 2-8-2 1-4-1 0-0-41-1-60-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.03 0.09 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=75/2-7-9, 3=75/2-7-9 Max Horz 1=18(LC 5) Max Uplift1=-3(LC 6), 3=-3(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V15 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548941 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:58 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-McVsuP06F44SogXJ5a_DleMFchkYSmvUcHWnfJzh_l? Scale = 1:37.6 1 2 3 5 42x4 2x4 2x4 2x4 2x4 5-11-1 5-11-1 0-0-44-11-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.47 0.27 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=-13/5-10-12, 4=125/5-10-12, 5=318/5-10-12 Max Horz 1=135(LC 5) Max Uplift1=-50(LC 4), 4=-32(LC 5), 5=-112(LC 6) Max Grav 1=90(LC 6), 4=125(LC 1), 5=318(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=112. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V16 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548942 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:59 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-qo2E6l0k0OCJQq6VfIVSIsuRp54lBEFdqxFLBlzh_l_ Scale = 1:23.2 1 2 32x4 2x4 2x4 3-11-1 3-11-1 0-0-43-3-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.44 0.27 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=135/3-10-12, 3=135/3-10-12 Max Horz 1=85(LC 5) Max Uplift3=-30(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V17 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548943 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:59 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-qo2E6l0k0OCJQq6VfIVSIsuVa56uBEkdqxFLBlzh_l_ Scale = 1:22.2 1 2 3 42x4 4x6 2x4 2x4 0-0-5 0-0-5 6-0-10 6-0-5 3-0-5 3-0-5 6-0-10 3-0-5 0-0-42-6-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.14 0.13 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=110/6-0-1, 3=110/6-0-1, 4=200/6-0-1 Max Horz 1=-51(LC 4) Max Uplift1=-11(LC 7), 3=-15(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V18 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548944 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:39:59 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-qo2E6l0k0OCJQq6VfIVSIsuT054HBETdqxFLBlzh_l_ Scale = 1:25.4 1 2 3 43x4 3x4 2x4 5x6 0-0-5 0-0-5 7-9-12 7-9-7 3-5-11 3-5-11 7-9-12 4-4-1 0-0-42-10-110-0-410.00 12 8.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.30 0.30 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=123/7-9-1, 3=155/7-9-1, 4=276/7-9-1 Max Horz 1=-60(LC 4) Max Uplift1=-15(LC 7), 3=-20(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V19 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548945 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:40:00 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-I_cdJ51MniKA2_hiD?0hr3RhKVSvwhUn3b?uiCzh_kz Scale = 1:10.7 1 2 3 2x4 3x4 2x4 0-0-5 0-0-5 3-3-12 3-3-7 1-5-11 1-5-11 3-3-12 1-10-1 0-0-41-2-110-0-410.00 12 8.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.07 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=97/3-3-1, 3=97/3-3-1 Max Horz 1=-21(LC 4) Max Uplift1=-3(LC 6), 3=-5(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V20 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548946 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:40:00 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-I_cdJ51MniKA2_hiD?0hr3Rf7VSAwhUn3b?uiCzh_kz Scale = 1:18.0 1 2 3 2x4 2x4 2x4 2-10-11 2-10-11 0-0-42-4-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.21 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=94/2-10-7, 3=94/2-10-7 Max Horz 1=59(LC 5) Max Uplift3=-21(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V21 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548947 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:40:00 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-I_cdJ51MniKA2_hiD?0hr3RcgVQ3whUn3b?uiCzh_kz Scale = 1:23.1 1 2 32x4 2x4 2x4 3-10-11 3-10-11 0-0-43-2-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.43 0.27 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=134/3-10-7, 3=134/3-10-7 Max Horz 1=84(LC 5) Max Uplift3=-29(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 Job B18800879 Truss V22 Truss Type Valley Qty 1 Ply 1 212 BRIDGEMONT AT JACKSONS GRA Job Reference (optional) I32548948 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Feb 27 08:40:01 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:ZboPm0OzEMgBGAdrxQaSe_zwTD4-mBA?WR2_X?S1f7GumiXxNHzs6vqnf8kwIFkRFezh_ky Scale = 1:13.0 1 2 3 2x4 2x4 2x4 1-10-11 1-10-11 0-0-41-6-1510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.07 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=54/1-10-7, 3=54/1-10-7 Max Horz 1=34(LC 5) Max Uplift3=-12(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 27,2018 edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 8 7 6 54321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 8 7 6 54321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System General Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.