HomeMy WebLinkAboutA111WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
ENTRY
101
CAFE
106
DW
MEET
102
OPEN OFFICE
107
TOWN HALL
105
MEET
112
MEET
113
COPY
108
FOCUS
111
FOCUS
110
STORAGE
104
IT
103
DEV
OPEN OFFICE
114
FOCUS
109
12'-9" 12'-2" 2'-6"
86°
86°
14'-1"
6'-5"
14'-5"
7'-01
2
"
6'-8
1
4"
8'-4"
CLEAR
4'-3" 10'-10"
15'-4
1
2"
9'-6"
98°
86°
8'-4" 8'-4" 8'-4"
9'-10" 1'-6"
12'-03
4
"
102°
94°
102°
FE
FE
2'-6"
102°
1'-11"
78°
82°
2'-21
2
"
17'-73
4
"
10'-6"
9'-0"
EXPOSED DECK ABOVE
FRONT EDGE OF 1'-6" DEEP
DRYWALL WING WALL;
CONTINUOUS WITH BULKHEAD
ABOVE
FRONT EDGE OF 1'-6" DEEP
DRYWALL BULKHEAD;
CONTINUOUS WITH WING
WALL BELOW
SEE DOOR SCHEDULE FOR
DOOR AND FRAME DETAILS
ARCHITECTURAL
FLOOR PLAN
A111
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x
3
4", PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET
AND FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
PROVIDE (5) 18" DEEP ADJUSTABLE WHITE MELAMINE SHELVES ON
HEAVY DUTY K/V BRACKETS AND STANDARDS.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
COLUMN TO REMAIN EXPOSED AND UNFINISHED.
PROVIDE CONCEALED/ IN-WALL SUPPORT BRACKETS AT PARTIAL
HEIGHT WALL FOR ISLAND TOP AS REQUIRED.
_______________________________________________________________
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM
LOCATION WITH TENANT.
PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT
PROVIDED DISHWASHER AT THIS LOCATION.
PLAN NOTES
AREA NOT IN CONTRACT ARCHITECTURAL PLAN
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT WINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL
PARTIAL HEIGHT WALL
WALL TO DECK WITH INSULATION
35
8" METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL
W1
W2
WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W3
W4
PARTIAL HEIGHT WALL
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 40";
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
N
0 2' 4' 8' 16'
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
GENERAL NOTES
NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
TYP.
A111
1
A2 11
2
A2 11
3
A2 11
4
W2
W2
W2 W2
W2
W2
W2
PARTIAL HEIGHT WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 10''-6";
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL;
SEE ELEVATION 2/A111 & RCP FOR MORE
INFORMATION
W4
W4
W4
W5
W3
A111
2
0 1' 2' 4'
ELEVATION - EXTERIOR OF FOCUS 109, 110 + 111
A111
2
W2
A211
6
W5
PARTIAL HEIGHT WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 9''-5";
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL;
SEE ELEVATION 2/A111 & RCP FOR MORE
INFORMATION
05/03/18
Nick Mishler