Loading...
HomeMy WebLinkAboutA111WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT METAL STUD EXISTING WINDOW MULLION EQUAL ENTRY 101 CAFE 106 DW MEET 102 OPEN OFFICE 107 TOWN HALL 105 MEET 112 MEET 113 COPY 108 FOCUS 111 FOCUS 110 STORAGE 104 IT 103 DEV OPEN OFFICE 114 FOCUS 109 12'-9" 12'-2" 2'-6" 86° 86° 14'-1" 6'-5" 14'-5" 7'-01 2 " 6'-8 1 4" 8'-4" CLEAR 4'-3" 10'-10" 15'-4 1 2" 9'-6" 98° 86° 8'-4" 8'-4" 8'-4" 9'-10" 1'-6" 12'-03 4 " 102° 94° 102° FE FE 2'-6" 102° 1'-11" 78° 82° 2'-21 2 " 17'-73 4 " 10'-6" 9'-0" EXPOSED DECK ABOVE FRONT EDGE OF 1'-6" DEEP DRYWALL WING WALL; CONTINUOUS WITH BULKHEAD ABOVE FRONT EDGE OF 1'-6" DEEP DRYWALL BULKHEAD; CONTINUOUS WITH WING WALL BELOW SEE DOOR SCHEDULE FOR DOOR AND FRAME DETAILS ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x 3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET AND FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE (5) 18" DEEP ADJUSTABLE WHITE MELAMINE SHELVES ON HEAVY DUTY K/V BRACKETS AND STANDARDS. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. COLUMN TO REMAIN EXPOSED AND UNFINISHED. PROVIDE CONCEALED/ IN-WALL SUPPORT BRACKETS AT PARTIAL HEIGHT WALL FOR ISLAND TOP AS REQUIRED. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT PROVIDED DISHWASHER AT THIS LOCATION. PLAN NOTES AREA NOT IN CONTRACT ARCHITECTURAL PLAN AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL WALL TO DECK WITH INSULATION 35 8" METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL W1 W2 WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W3 W4 PARTIAL HEIGHT WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 40"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR N 0 2' 4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. GENERAL NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 TYP. A111 1 A2 11 2 A2 11 3 A2 11 4 W2 W2 W2 W2 W2 W2 W2 PARTIAL HEIGHT WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 10''-6"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; FIBERGLASS SOUND BATT INSULATION INSIDE WALL; SEE ELEVATION 2/A111 & RCP FOR MORE INFORMATION W4 W4 W4 W5 W3 A111 2 0 1' 2' 4' ELEVATION - EXTERIOR OF FOCUS 109, 110 + 111 A111 2 W2 A211 6 W5 PARTIAL HEIGHT WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 9''-5"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; FIBERGLASS SOUND BATT INSULATION INSIDE WALL; SEE ELEVATION 2/A111 & RCP FOR MORE INFORMATION 05/03/18 Nick Mishler