HomeMy WebLinkAboutA121R R R R R R R R R R R R R R R R R R R R R R R R R S N S N S N R R R R R R NL NL NL NL NL SN SN SN S N S N3 S N3 ELN ELN ELN ELN ELN ELN 10'-6" 11'-0" 10'-6" 11'-0" 11'-0" 12-0" 12'-0" 82° 6'-2 1 2 " SN 4'-6" S NG EQ. EQ. SN REFLECTED CEILING PLAN A121 CONTROL ENTRY, TOWN HALL, CAFE, COPY AND OPEN OFFICE LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. PROVIDE (4) 32" LONG UNDER CABINET LIGHT FIXTURES, BRUCK WUNDERCAB, 138540LED-32-35K, CONTROLLED WITH SEPARATE SWITCH. SEE ELEVATION FOR MORE INFORMATION. PROVIDE DRYWALL CEILING AT 10'-0" AFF AT THIS LOCATION. CEILING TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. WHERE APPLICABLE, TRANSITION FROM DRYWALL CEILING TO EXPOSED CEILING TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. CLEAN ALL EXPOSED SURFACES AND PREPARE FOR DRYFALL PAINT (PT4) PER MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. PROVIDE RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED IN THIS AREA. PORTION OF DRYWALL CEILING OUTSIDE OF FOCUS ROOM TO BE ANGLED. VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO DECK AT THIS LOCATION. SEE ELEVATION 2/A111 FOR MORE INFORMATION. EXPOSED CEILING ABOVE FOCUS ROOMS TO BE PAINTED WITH DRYFALL PAINT (PT4). NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. PROVIDE FLOATING DRYWALL CEILING AT 9'-0" AFF AT THIS LOCATION WITH 6" ARMSTRONG AXIOM TRIM AT EXPOSED EDGE. VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO DECK AT THIS LOCATION. EXTEND DRYFALL PAINT ON DECK ABOVE BEYOND EDGE OF BULKHEAD AS FAR BACK AS REQUIRED SUCH THAT ALL VISIBLE DECK AND COMPONENTS FROM EYE-LEVEL AT ANY POINT IN THE SPACE IS FINISHED WITH PT4. NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. DESIGN INTENT IS FOR ANGLE OF DRYWALL BULKHEAD TO ALIGN WITH WALL ANGLE AND FLOORING TRANSITION BELOW. PROVIDE DRYWALL CEILING AT 9'-0" AFF AT THIS LOCATION. CEILING TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. SEE ELEVATION 2/A111 FOR MORE INFORMATION. EXPOSED CEILING ABOVE FOCUS ROOMS TO BE PAINTED WITH DRYFALL PAINT (PT4). NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. DESIGN INTENT IS FOR SEAMLESS TRANSITION FROM HP-ID SUSPENDED FIXTURE TO HP-4 R RECESSED FIXTURE. TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 4" WIDE DRYWALL BULKHEAD EXTENDING FROM 9'-0" AFF TO EXPOSED CEILING. TRANSITION FROM DRYWALL CEILING TO EXPOSED CEILING TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL. 1. WHERE SHOWN, PROVIDE NEW 2'x2' 9 16" CEILING GRID AND 2'x2' FINE FISSURED REVEAL EDGE CEILING TILE (ARMSTRONG DUNE, OR SIMILAR). GRID TO BE INSTALLED AT 9'-0" AFF. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES PLAN NOTES SWITCH, PROJECTOR SCREEN LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH NP ND N N3 EXIT LIGHT FIXTURE, LED EDGE LIT LIGHT FIXTURE, 2'x2', LED, COLUMBIA LIGHTING - LCAT RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' AT 9'-0" AFF NIGHT LIGHT NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. NEW OR RELOCATED EXISTING TO REMAIN DIRECT PENDANT, LED, FINELITE HP-4-D, BOTTOM OF FIXTURES AT 9'-0" AFF, LENGTHS VARY, COORDINATE WITH ESL SPECTRUM, JENNIFER HALL 317.750.7221 jhall@esl-spectrum.com GYPSUM BOARD CEILING AT 9'-0" AFF LEGEND REFLECTED CEILING PLAN DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR N 0 2' 4' 8' 16' EMERGENCY LIGHT FIXTURE 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES A121 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) NG EXPOSED TO DECK AREA NOT IN CONTRACT AREA OF WORK RECESSED LIGHT FIXTURE, LED, FINELITE HP-4-R, LENGTHS VARY, COORDINATE WITH ESL SPECTRUM, JENNIFER HALL 317.750.7221 jhall@esl-spectrum.com R 2'-6" 05/03/18 Nick Mishler