10'-6" 11'-0" 10'-6" 11'-0" 11'-0" 12-0" 12'-0"
82°
6'-2
1
2
"
SN
4'-6"
S
NG
EQ.
EQ.
SN
REFLECTED
CEILING PLAN
A121
CONTROL ENTRY, TOWN HALL, CAFE, COPY AND OPEN OFFICE
LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE
MULTIPLE SWITCHES AS REQUIRED.
PROVIDE (4) 32" LONG UNDER CABINET LIGHT FIXTURES, BRUCK
WUNDERCAB, 138540LED-32-35K, CONTROLLED WITH SEPARATE
SWITCH. SEE ELEVATION FOR MORE INFORMATION.
PROVIDE DRYWALL CEILING AT 10'-0" AFF AT THIS LOCATION.
CEILING TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH.
WHERE APPLICABLE, TRANSITION FROM DRYWALL CEILING TO
EXPOSED CEILING TO BE A CLEAN VERTICAL BULKHEAD, FINISHED
SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND
CLEANLY CUT AT WALL TO CEILING LINE.
CLEAN ALL EXPOSED SURFACES AND PREPARE FOR DRYFALL PAINT
(PT4) PER MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING
EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING,
JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND
FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. PROVIDE
RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY DIFFUSERS AS
REQUIRED IN THIS AREA.
PORTION OF DRYWALL CEILING OUTSIDE OF FOCUS ROOM TO BE
ANGLED. VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO
DECK AT THIS LOCATION. SEE ELEVATION 2/A111 FOR MORE
INFORMATION. EXPOSED CEILING ABOVE FOCUS ROOMS TO BE
PAINTED WITH DRYFALL PAINT (PT4). NOTE THAT SPRINKLERS MAY
BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA.
PROVIDE FLOATING DRYWALL CEILING AT 9'-0" AFF AT THIS
LOCATION WITH 6" ARMSTRONG AXIOM TRIM AT EXPOSED EDGE.
VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO DECK AT THIS
LOCATION. EXTEND DRYFALL PAINT ON DECK ABOVE BEYOND
EDGE OF BULKHEAD AS FAR BACK AS REQUIRED SUCH THAT ALL
VISIBLE DECK AND COMPONENTS FROM EYE-LEVEL AT ANY POINT
IN THE SPACE IS FINISHED WITH PT4. NOTE THAT SPRINKLERS MAY BE
REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. DESIGN
INTENT IS FOR ANGLE OF DRYWALL BULKHEAD TO ALIGN WITH
WALL ANGLE AND FLOORING TRANSITION BELOW.
PROVIDE DRYWALL CEILING AT 9'-0" AFF AT THIS LOCATION.
CEILING TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. SEE
ELEVATION 2/A111 FOR MORE INFORMATION. EXPOSED CEILING
ABOVE FOCUS ROOMS TO BE PAINTED WITH DRYFALL PAINT (PT4).
NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW
CEILING IN THIS AREA.
DESIGN INTENT IS FOR SEAMLESS TRANSITION FROM HP-ID
SUSPENDED FIXTURE TO HP-4 R RECESSED FIXTURE.
TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 4"
WIDE DRYWALL BULKHEAD EXTENDING FROM 9'-0" AFF TO
EXPOSED CEILING. TRANSITION FROM DRYWALL CEILING TO
EXPOSED CEILING TO BE A CLEAN VERTICAL BULKHEAD, FINISHED
SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND
CLEANLY CUT AT WALL TO CEILING LINE. VERTICAL FACE OF
DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL.
1. WHERE SHOWN, PROVIDE NEW 2'x2'
9
16" CEILING GRID AND
2'x2' FINE FISSURED REVEAL EDGE CEILING TILE (ARMSTRONG
DUNE, OR SIMILAR). GRID TO BE INSTALLED AT 9'-0" AFF.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS
REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS
OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE
ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN
RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH
PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH
DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO
INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1
STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO
MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER
50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO
ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET.
4. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE
OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH
ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE
BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR
RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI).
EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE.
5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE
WHITE. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO
ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE
SHOWN ADJACENT ON PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND
IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS
LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL
OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE
CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE
BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE
PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
GENERAL NOTES PLAN NOTES
SWITCH, PROJECTOR SCREEN
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
NP
ND
N
N3
EXIT LIGHT FIXTURE, LED
EDGE LIT
LIGHT FIXTURE, 2'x2', LED,
COLUMBIA LIGHTING -
LCAT
RELOCATED
DIFFUSER, LAY-IN, 4"x4'
RELOCATED
DIFFUSER, LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2' AT
9'-0" AFF
NIGHT LIGHT
NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
NEW OR RELOCATED EXISTING TO REMAIN
DIRECT PENDANT, LED,
FINELITE HP-4-D, BOTTOM
OF FIXTURES AT 9'-0" AFF,
LENGTHS VARY,
COORDINATE WITH ESL
SPECTRUM, JENNIFER HALL
317.750.7221
jhall@esl-spectrum.com
GYPSUM BOARD
CEILING AT 9'-0" AFF
LEGEND
REFLECTED CEILING PLAN
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
N
0 2' 4' 8' 16'
EMERGENCY LIGHT
FIXTURE
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE
AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN
MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO
RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL
LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING
ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY
WITH THE INDIANA MECHANICAL CODE AND ALL OTHER
APPLICABLE CODES.
MECHANICAL NOTES
A121
1
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
VAV /
HEAT PUMP
SWITCH, GARBAGE DISPOSAL
(ABOVE COUNTERTOP)
NG
EXPOSED TO DECK
AREA NOT IN CONTRACT
AREA OF WORK
RECESSED LIGHT FIXTURE,
LED, FINELITE HP-4-R,
LENGTHS VARY,
COORDINATE WITH ESL