DOCUMENT APPROVAL
TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS.
___________________________________ _____________________________________________ _____________________________________________ ___________
TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE
ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN-OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT.
THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.
GENERAL PROJECT NOTES
1. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO
BASIC DESIGN-BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE
DESIGN-BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY
FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR
PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY
ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL
INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL,
ELECTRICAL AND PLUMBING DESIGN-BUILD CONTRACTORS SHALL COMPLY WITH ALL
APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM
SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-BUILD CONTRACTOR AND
MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE
SUPPRESSION AND FIRE ALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FOR
COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS.
2. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST
COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE
ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE
OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE
OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING
OWNER/LANDLORD.
4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES AS REQUIRED. PROVIDE
PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES.
CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS
REQUIRED BY CODE.
5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR
OTHER CONFLICTS.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF
THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL
PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER
APPLICABLE CODES.
8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER
AND DATA OUTLETS AS REQUIRED.
9. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE G.F.C.I.
10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO
BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND
PROVIDING APPROPRIATE TERMINALS AT FACE PLATE.
11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCHPLATES TO MATCH
EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO
PURCHASE.
12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN.
REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE
ENTRY
1 01
CAFE
1 06
DW
x
MEET
1 02
14'-1" 11'-10"
OPEN OFFICE
1 07
TOWN HALL
1 05
x
MEET
1 1 2
1 6'-5" 1 2'-7"
x
MEET
1 1 3
1 3'-9" 1 3'-7"
COPY
1 08
x
FOCUS
111
9'-6" 8'-0"
x
FOCUS
1 1 0
9'-6" 8'-0"
STORAGE
1 04
96 SF
IT
1 03
88 SF
DEV
OPEN OFFICE
1 1 4
x
FOCUS
1 09
9'-6" 8'-0"
ELN
ELN ELN ELN
ELN
ELN
FE
FE
LIFE SAFETY
L100
LIFE SAFETY PLAN
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DEMOLITION PLAN
DEMOLITION PLAN
D111
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
N
0 2' 4' 8' 16'
ELECTRIC OUTLET(S)
DATA OR
COMMUNICATION
OUTLET
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT
WALL
DOOR AND FRAME
CEILING GRID AND
TILES, 2'x4'
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
LIGHT FIXTURE, CAN
LIGHT SWITCH
LIGHT FIXTURE,
FLUORESCENT, 2'x2'
WINDOW / SIDELIGHT
CEILING GRID AND
TILES, 2'x2'
LIGHT FIXTURE, TRACK
LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
EXIT LIGHT
WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
ENTRY
101
CAFE
106
DW
MEET
102
OPEN OFFICE
107
TOWN HALL
105
MEET
112
MEET
113
COPY
108
FOCUS
111
FOCUS
110
STORAGE
104
IT
103
DEV
OPEN OFFICE
114
FOCUS
109
12'-9" 12'-2" 2'-6"
86°
86°
14'-1"
6'-5"
14'-5"
7'-01
2
"
6'-8
1
R
R
R R
R
R
R
R
R R R R
R
R R R
R
R
R
R
R
R
R
R
R
S
N
S
N
S
N
R R
R R
R R
NL
NL
NL
NL
NL
SN
SN
SN
S
N
S
N3
S
N3
ELN
ELN ELN ELN
ELN
ELN
10'-6" 11'-0" 10'-6" 11'-0" 11'-0" 12-0" 12'-0"
82°
6'-2
1
2
"
SN
4'-6"
S
NG
EQ.
EQ.
SN
REFLECTED
ENTRY
101
CAFE
106
DW
MEET
102
OPEN OFFICE
107
TOWN HALL
105
MEET
112
MEET
113
COPY
108
FOCUS
111
FOCUS
110
STORAGE
104
IT
103
DEV
OPEN OFFICE
114
FOCUS
109
FINISH PLAN
A131
CARPET
FLOOR COVERINGS
MFG: TBD ($28/SQ. YD. INSTALLED COST ALLOWANCE)
TYPE: --
PATTERN: --
COLOR: --
CONCRETE
EXISTING CONCRETE FLOOR TO BE SEALED
AND POLISHED
WALL BASE
MFG: JOHNSONITE
TYPE: 4" VINYL COVE,
1
8" GAUGE
COLOR: --
PAINT / WALLCOVERING
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: --
FINISH: EGGSHELL
MFG: TBD ($19.95/LINEAR YD. MATERIAL COST ALLOWANCE)
TYPE: VINYL
PATTERN: --
COLOR: --
PLASTIC LAMINATE / QUARTZ
MFG: TBD
COLOR: --
MISCELLANEOUS
3'-0"
ADA
(321
4" H)
DISHWASHER
BY
TENANT
2'-0"
2'-8"
REFRIG. BY
TENANT
3'-3"
(HOLD)
2'-10" 1 '-9" 2'-6"
WALL CABINETS
(SEE CASEWORK NOTE 1 )
SINGLE BOWL UNDER-MOUNT SINK: 18
GAUGE STAINLESS STEEL ELKAY
301
2"x18
1
2"x5
3
8" #ELUHAD281655 (OR
EQUAL) WITH KOHLER SIMPLICE FAUCET
#K-597-BL AND GARBAGE DISPOSAL
24" DEEP QUARTZ (QZ_) COUNTERTOP,
EXTEND AT ANGLED PORTION OF WALL
BASE CABINETS (SEE CASEWORK NOTE 1 )
OPEN ABOVE,
EXPOSED TO
DECK
DRYWALL BULKHEAD, SEE
DIMENSIONS ON
REFLECTED CEILING PLAN
1'-11"
ANGLED PORTION OF
WALL
FILLER PANEL AT ANGLED PORTION OF
WALL TO MATCH CASEWORK AT BASE
AND UPPER CABINETS
EXTEND DRYFALL PAINT ON DECK
ABOVE BEYOND EDGE OF BULKHEAD
AS FAR BACK AS REQUIRED SUCH THAT
ALL VISIBLE DECK AND COMPONENTS
FROM EYE-LEVEL AT ANY POINT IN THE
SPACE IS FINISHED WITH PT_.
MICROWAVE
BOX
2'-6"
1 '-31
2
"
1'-5"
3'-0"
1 '-6"
(2) BUILT-IN FULL SIZE KEGERATORS WITH
STAINLESS STEEL DOOR AND
INTEGRATED DRAIN SYSTEM; TAP
HANDLES AND DRIP TRAYS TO BE
ENTRY
101
REFRIG
BY
TENANT
CAFE
106
DW
MEET
102
OPEN OFFICE
107
TOWN HALL
105
MEET
112
MEET
113
COPY
108
FOCUS
111
FOCUS
110
STORAGE
104
IT
103
DEV
OPEN OFFICE
114
FOCUS
109
TV
TV
+60"
+60"
+48"
+48"
+44"
+44"
+44"
J
J
J
J
J
J
+42"
+42"
GFCI
GFCI
+24"
+60"
+60"
+60"
+60"
DED
DED
+44"
+72"
+72"
+72"
+72"
ELECTRICAL PLAN
E111
PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE OR
MAGLOCK AT DOOR FOR CARD READER (CARD READER BY
TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR.
SEE DOOR SCHEDULE FOR MORE DETAILS.
NOT USED.
PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
24" A.F.F.
PROVIDE POWER AND DATA AT HEIGHT NOTED ON PLAN FOR
TENANT'S WALL MOUNTED TELEVISION. COORDINATE EXACT
LOCATION WITH TENANT.
PROVIDE POWER AT THIS LOCATION FOR TENANT'S DISHWASHER
AND GARBAGE DISPOSAL.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
FOR ELECTRICAL AND DATA FOR TENANT'S WORKSTATIONS.
COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT
LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT
FOR APPROVAL PRIOR TO ORDERING.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POWER AND DATA
CENTERED IN ROOM WITH CONDUIT CONNECTION TO TENANT'S
WALL MOUNTED TELEVISION.
PLAN NOTES
ELECTRICAL PLAN
LEGEND
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
N
0 2' 4' 8' 16'
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE.
REPLACE WITH NEW AS REQUIRED.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
GENERAL NOTES
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
BOX, BLANK COVER PLATE
BOX, OPEN
POWER POLE FOR
ELECTRICAL AND DATA.
PROVIDE JUNCTION BOX
ABOVE CEILING.
POWER AND DATA POLE
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
CEILING MOUNTED
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
J
J
B
O
J
+42"
AREA NOT IN CONTRACT
AREA OF WORK
05/03/18
Nick Mishler
INCORPORATED INTO COUNTERTOP
PROVIDE (4) 32" LONG UNDER CABINET
LIGHT FIXTURES, BRUCK WUNDERCAB,
138540LED-32-35K, CONTROLLED WITH
SEPARATE SWITCH, INSTALLED AT BACK
OF CABINET
2'-0" 2'-0"
2'-0" 2'-0"
3'-6"
2'-8" 2'-8"
EXIST
4"V.
EXIST
4"W.
2"W.
F.F.
2"W.
2"W.
SINK
TO
BUILDING
DRAIN
F.F.
11
2"V.
CLG.
11
2"V.
CLG.
TO EXISTING
STACK
F1 F2
8'-2"
3'-0"
3'-4"
2" 2"
8'-0" 2"
F3
7'-10"
2" 3'-0"
8'-2"
8'-0" 2"
2" 4'-4" 2"
3
8" TEMPERED
GLASS
9'-6"
2" 3'-0"
8'-2"
8'-0" 2"
2" 6'-0" 2"
3
8" TEMPERED
GLASS,
BUTT-GLAZED
8'-0"
D1
3'-0"
1'-0" 8"
7" 7"
8'-0"
3'-0"
D2 D3
9'-0"
3'-0" 2'-6"
1
4" TEMPERED
GLASS, WOOD
FLUSH BEAD
STAINED TO
MATCH DOOR
4" STAINLESS STEEL
TOP RAIL
1 /2" TEMPERED GLASS
PROVIDE ONE PULL ON
EACH SIDE OF EACH
DOOR (TOTAL COUNT 4)
AS NOTED IN REMARKS
4" STAINLESS STEEL
BOTTOM RAIL
2'-6" 3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0" 1 '-9" 2'-6"
WALL CABINETS
(SEE CASEWORK NOTE 1 )
25" DEEP QUARTZ (QZ_)
COUNTERTOP WITH 4" HIGH
BACKSPLASH
BASE CABINETS
(SEE CASEWORK NOTE 1 )
4'-6"
HOLD
1 '-6" 3'-0"
OPEN
BELOW
3'-6"
4'-0" X 11'-0" QUARTZ(QZ_)
ISLAND AT 42"A.F.F. WITH
MITER FOLD EDGE DETAIL AT
CORNER SUCH THAT
HORIZONTAL QUARTZ
PATTERN TRANSITIONS TO
VERTICAL DIRECTION AND
EXTENDS TO FLOOR (NO
VINYL BASE AT QUARTZ).
ISLAND CENTERED ON WALL
BELOW, PROVIDE
CONCEALED/IN-WALL
SUPPORTS AS REQUIRED.
PARTIAL HEIGHT WALL
BELOW, PAINTED (PT_)
1 1 '-0"
BASE AS SCHEDULED
7" 7" 7"
1'-0"
(TYP.)
3'-6"
7" 7"
1'-0"
(TYP.)
7"
1
4" BIRCH VENEER
PLYWOOD ON
1
4" MDF
6" METAL STUDS @
APPROX. 16" O.C.
1
4" ROUND-OVER, TOP
AND BOTTOM EDGE
3
4" BIRCH VENEER
UNFINISHED PLYWOOD
1
2
"
6" METAL STUDS @
APPROX. 16" O.C.
LEDGER BOARD
4'-6" 12'-0"
1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-0"
SUPPORTING WALLS TO
BE BUILT WITH 6" METAL
STUDS, UNFINISHED
BIRCH PLYWOOD SEATS
TO BE BUILT IN SECTIONS
AS REQUIRED; CONFIRM
ANGLE AND EXACT
DIMENSIONS IN FIELD
PROVIDE CODE COMPLIANT
POWDER COATED ALUMINUM
HAND RAIL AS REQUIRED AT STEPS,
FINISH: TBD
PROVIDE CODE
COPLIANT GUARD RAIL
ALONG OPEN EDGE OF
SEATING PER IBC 1013.2,
FINISH: TBD
NOTE: TOWN HALL SEATING OCCUPANT LOAD = 16
NUMBER OF OCCUPANTS BASED ON 18" WIDTH OF SPACE PER
PERSON. ONE AISLE REQUIRED PER IBC TABLE 1021.2
DOOR SCHEDULE
# DIMENSIONS DOOR FRAME HARDWARE REM.
01 3'-0"X9'-0" (PAIR) R2,R3
02 PS
03 SL, CL
04 SL, CL
09 PP, CL R3
10 PP, CL R3
11 PP, CL R3
12 PS
13 PS
14 R1
DOOR SCHEDULE
INTERIOR DETAILS
A211
TYPICAL ALL SINGLE LOCATIONS,
GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN
ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF
BASE CABINET PRIOR TO ORDERING.
1. PROVIDE A.W.I. CUSTOM GRADE, FLUSH-OVERLAY CABINETS.
FABRICATE WITH PLASTIC LAMINATE (PL_) COVERED M.D.O. BOARD
WITH MOCKETT ______ PULLS. COORDINATE WITH ELEVATIONS FOR
QUANTITIES.
- AT CAFE 106 PROVIDE:
24" DEEP COUNTERTOPS
23" DEEP BASE CABINETS
11
1
2" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS
- AT COPY 108 PROVIDE:
25" DEEP COUNTERTOPS
24" DEEP BASE CABINETS
11
1
2" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS
- 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS
NOTED OTHERWISE.
CASEWORK NOTES
CL CLOSER
CR CARD READER BY TENANT (N.I.C.)
DL DUMMY LEVER
EL ELECTROMAGNETIC LOCK (PER IBC 2012)
ES ELECTRIC STRIKE BY TENANT (N.I.C.)
OL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSH/PULL - PROVIDE ONE ROCKWOOD POST MOUNT PULL ON
EACH SIDE OF DOOR (TOTAL COUNT 2 AT EACH DOOR). PULL TO BE
20", CLEAR ANODIZED WITH SQUARE ENDS, RM3120-20 628.
PS PASSAGE LATCHSET
RL ROLLER LATCHES
SL STOREROOM LOCKSET
HARDWARE LEGEND
NOTE: REFER TO FLOORPLAN
AND CASEWORK ELEVATIONS
FOR SINK LOCATIONS.
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
DOOR/FRAME TYPES
0 1' 2' 4'
ELEVATION - CAFE 106
A211
3
NOT TO SCALE
RISER DIAGRAM
A211
1
EXISTING -- -- SEE REMARK -- -- CR, ES, SL, CL
R1. FINISH TENANT SIDE OF DOOR AND FRAME TO MATCH SUITE
STANDARD STAIN COLOR. FINISH CORRIDOR SIDE OF DOOR AND
FRAME TO MATCH BUILDING STANDARD STAIN COLOR IN
COMMON CORRIDOR.
R2. CAP ENDS AND HEADER OF DRYWALL WRAPPED OPENING WITH
ALUMINUM CASING.
R3. PULLS TO BE ROCKWOOD 20" RM4020-US32D WITH HICKORY
WOOD AND BACK TO BACK MOUNTING.
3'-0"x8'-0"x1
3
4" D2
SOLID CORE
BIRCH VNR.
STAIN TBD F3 TIMELY ALUMATONE
REMARKS
DOOR/FRAME NOTES
1. PROVIDE PREMIUM WHITE BIRCH VENEER, PLAIN SLICED, GRADE A PER
WDMA I.S. #1-A BOOK MATCHED WHITE BIRCH WITH NO HEART WOOD,
ONLY SAP WOOD (LIGHT COLORED WOOD). PRE-MACHINE NEW DOORS
FOR CYLINDRICAL LOCKSETS.
2. PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE A.D.A.
ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS.
3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL
CORNERS UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND
LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION,
PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED
ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES.
ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE
INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
· 7'-0" HT. TO HAVE 3 HINGES
· GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
· FINISH TO MATCH HARDWARE SET
8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE
NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR
UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL
STOP.
TYPE MATERIAL FINISH TYPE MATERIAL FINISH
D3 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING EL, CR, CL
3'-0"x8'-0"x1
3
4" D1
SOLID CORE
BIRCH VNR.
STAIN TBD F1 TIMELY ALUMATONE
3'-0"x8'-0"x1
3
4" D1
SOLID CORE
BIRCH VNR.
STAIN TBD F1 TIMELY ALUMATONE
3'-0"x8'-0"x1
3
4" D2
SOLID CORE
BIRCH VNR.
STAIN TBD F2 TIMELY ALUMATONE
3'-0"x8'-0"x1
3
4" D2
SOLID CORE
BIRCH VNR.
STAIN TBD F2 TIMELY ALUMATONE
3'-0"x8'-0"x1
3
4" D2
SOLID CORE
BIRCH VNR.
STAIN TBD F2 TIMELY ALUMATONE
3'-0"x8'-0"x1
3
4" D2
SOLID CORE
BIRCH VNR.
STAIN TBD F3 TIMELY ALUMATONE
3'-0"x8'-0"x1
3
4" D2
SOLID CORE
BIRCH VNR.
STAIN TBD F3 TIMELY ALUMATONE
SEE REMARK
0 1' 2' 4'
ELEVATION - COPY 108
A211
2
0 1' 2' 4'
ELEVATION - CAFE 106
A211
4
7 TYP. SECTION THRU TOWN HALL SEATING
A211 0 6" 1' 2'
0 3" 6" 1' 2'
5 TYPICAL SECTION THRU BENCH
A211
A21 1
5
0 1' 2' 4'
ENLARGED PLAN - TOWN HALL 105
A211
6
A21 1
7
05/03/18
Nick Mishler
MFG: TBD
COLOR: --
PATTERN: --
FINISH PLAN
PLAN NOTES
MFG: TBD
COLOR: --
MFG: TBD
COLOR: --
MFG: TBD
COLOR: --
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
N
0 2' 4' 8' 16'
LEGEND
MFG: TBD ($6/SQ. FT. INSTALLED COST ALLOWANCE)
SIZE: --
PATTERN: --
COLOR: --
NOTE: PROVIDE SKIMCOAT OF ARDEX LEVELING LATEX
AS NEEDED FOR SMOOTH SUBFLOOR THAT WILL NOT
ALLOW FOR TELEGRAPHING OF IMPERFECTIONS IN THE
FLOOR
LUXURY VINYL TILE
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: --
FINISH: EGGSHELL
MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: --
FINISH: EGGSHELL
PROVIDE SCHLUTER SCHIENE TRANSITION STRIP AT FLOORING
TRANSITION, FINISH: BRUSHED STAINLESS STEEL (EB). PROVIDE
LEVELING LATEX UNDER CARPET AS SUCH THAT TOP OF FINISHES
ARE LEVEL. SEAM SEAL CARPET EDGES. CONTRACTOR TO
CONFIRM THAT TRANSITION PROFILE IS APPROPRIATE FOR
FLOORING MATERIALS.
PROVIDE JOHNSONITE SLIM LINE "J" PROFILE TRANSITION STRIP
CTA-XXX-J AT CONCRETE FLOORING TRANSITION, COLOR: TBD.
WALL FINISH AND VINYL BASE TO MATCH COMMON CORRIDOR
BUILDING STANDARD; COORDINATE WITH LANDLORD.
MFG: KRYLON
TYPE: ACRYLIC DRYFALL
COLOR: --
AREA NOT IN CONTRACT
AREA OF WORK
MFG: TBD ($28/SQ. YD. INSTALLED COST ALLOWANCE)
TYPE: --
PATTERN: --
COLOR: --
A211
6
MFG: TBD ($15/SQ. FT. MATERIAL COST ALLOWANCE)
TYPE: TILE PATTERN: --
COLOR: --
05/03/18
Nick Mishler
CEILING PLAN
A121
CONTROL ENTRY, TOWN HALL, CAFE, COPY AND OPEN OFFICE
LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE
MULTIPLE SWITCHES AS REQUIRED.
PROVIDE (4) 32" LONG UNDER CABINET LIGHT FIXTURES, BRUCK
WUNDERCAB, 138540LED-32-35K, CONTROLLED WITH SEPARATE
SWITCH. SEE ELEVATION FOR MORE INFORMATION.
PROVIDE DRYWALL CEILING AT 10'-0" AFF AT THIS LOCATION.
CEILING TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH.
WHERE APPLICABLE, TRANSITION FROM DRYWALL CEILING TO
EXPOSED CEILING TO BE A CLEAN VERTICAL BULKHEAD, FINISHED
SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND
CLEANLY CUT AT WALL TO CEILING LINE.
CLEAN ALL EXPOSED SURFACES AND PREPARE FOR DRYFALL PAINT
(PT4) PER MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING
EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING,
JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND
FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. PROVIDE
RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY DIFFUSERS AS
REQUIRED IN THIS AREA.
PORTION OF DRYWALL CEILING OUTSIDE OF FOCUS ROOM TO BE
ANGLED. VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO
DECK AT THIS LOCATION. SEE ELEVATION 2/A111 FOR MORE
INFORMATION. EXPOSED CEILING ABOVE FOCUS ROOMS TO BE
PAINTED WITH DRYFALL PAINT (PT4). NOTE THAT SPRINKLERS MAY
BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA.
PROVIDE FLOATING DRYWALL CEILING AT 9'-0" AFF AT THIS
LOCATION WITH 6" ARMSTRONG AXIOM TRIM AT EXPOSED EDGE.
VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO DECK AT THIS
LOCATION. EXTEND DRYFALL PAINT ON DECK ABOVE BEYOND
EDGE OF BULKHEAD AS FAR BACK AS REQUIRED SUCH THAT ALL
VISIBLE DECK AND COMPONENTS FROM EYE-LEVEL AT ANY POINT
IN THE SPACE IS FINISHED WITH PT4. NOTE THAT SPRINKLERS MAY BE
REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. DESIGN
INTENT IS FOR ANGLE OF DRYWALL BULKHEAD TO ALIGN WITH
WALL ANGLE AND FLOORING TRANSITION BELOW.
PROVIDE DRYWALL CEILING AT 9'-0" AFF AT THIS LOCATION.
CEILING TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. SEE
ELEVATION 2/A111 FOR MORE INFORMATION. EXPOSED CEILING
ABOVE FOCUS ROOMS TO BE PAINTED WITH DRYFALL PAINT (PT4).
NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW
CEILING IN THIS AREA.
DESIGN INTENT IS FOR SEAMLESS TRANSITION FROM HP-ID
SUSPENDED FIXTURE TO HP-4 R RECESSED FIXTURE.
TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 4"
WIDE DRYWALL BULKHEAD EXTENDING FROM 9'-0" AFF TO
EXPOSED CEILING. TRANSITION FROM DRYWALL CEILING TO
EXPOSED CEILING TO BE A CLEAN VERTICAL BULKHEAD, FINISHED
SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND
CLEANLY CUT AT WALL TO CEILING LINE. VERTICAL FACE OF
DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL.
1. WHERE SHOWN, PROVIDE NEW 2'x2'
9
1 6" CEILING GRID AND
2'x2' FINE FISSURED REVEAL EDGE CEILING TILE (ARMSTRONG
DUNE, OR SIMILAR). GRID TO BE INSTALLED AT 9'-0" AFF.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS
REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS
OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE
ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN
RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH
PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH
DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO
INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1
STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO
MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER
50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO
ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET.
4. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE
OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH
ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE
BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR
RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI).
EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE.
5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE
WHITE. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO
ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE
SHOWN ADJACENT ON PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND
IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS
LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL
OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE
CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE
BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE
PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
GENERAL NOTES PLAN NOTES
SWITCH, PROJECTOR SCREEN
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
NP
ND
N
N3
EXIT LIGHT FIXTURE, LED
EDGE LIT
LIGHT FIXTURE, 2'x2', LED,
COLUMBIA LIGHTING -
LCAT
RELOCATED
DIFFUSER, LAY-IN, 4"x4'
RELOCATED
DIFFUSER, LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2' AT
9'-0" AFF
NIGHT LIGHT
NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
NEW OR RELOCATED EXISTING TO REMAIN
DIRECT PENDANT, LED,
FINELITE HP-4-D, BOTTOM
OF FIXTURES AT 9'-0" AFF,
LENGTHS VARY,
COORDINATE WITH ESL
SPECTRUM, JENNIFER HALL
317.750.7221
jhall@esl-spectrum.com
GYPSUM BOARD
CEILING AT 9'-0" AFF
LEGEND
REFLECTED CEILING PLAN
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
N
0 2' 4' 8' 16'
EMERGENCY LIGHT
FIXTURE
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE
AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN
MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO
RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL
LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING
ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY
WITH THE INDIANA MECHANICAL CODE AND ALL OTHER
APPLICABLE CODES.
MECHANICAL NOTES
A121
1
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
VAV /
HEAT PUMP
SWITCH, GARBAGE DISPOSAL
(ABOVE COUNTERTOP)
NG
EXPOSED TO DECK
AREA NOT IN CONTRACT
AREA OF WORK
RECESSED LIGHT FIXTURE,
LED, FINELITE HP-4-R,
LENGTHS VARY,
COORDINATE WITH ESL
SPECTRUM, JENNIFER HALL
317.750.7221
jhall@esl-spectrum.com
R
2'-6"
05/03/18
Nick Mishler
4"
8'-4"
CLEAR
4'-3" 10'-10"
15'-4
1
2"
9'-6"
98°
86°
8'-4" 8'-4" 8'-4"
9'-10" 1'-6"
12'-03
4
"
102°
94°
102°
FE
FE
2'-6"
102°
1'-11"
78°
82°
2'-21
2
"
17'-73
4
"
10'-6"
9'-0"
EXPOSED DECK ABOVE
FRONT EDGE OF 1 '-6" DEEP
DRYWALL WING WALL;
CONTINUOUS WITH BULKHEAD
ABOVE
FRONT EDGE OF 1 '-6" DEEP
DRYWALL BULKHEAD;
CONTINUOUS WITH WING
WALL BELOW
SEE DOOR SCHEDULE FOR
DOOR AND FRAME DETAILS
ARCHITECTURAL
FLOOR PLAN
A111
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x
3
4", PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET
AND FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
PROVIDE (5) 18" DEEP ADJUSTABLE WHITE MELAMINE SHELVES ON
HEAVY DUTY K/V BRACKETS AND STANDARDS.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
COLUMN TO REMAIN EXPOSED AND UNFINISHED.
PROVIDE CONCEALED/ IN-WALL SUPPORT BRACKETS AT PARTIAL
HEIGHT WALL FOR ISLAND TOP AS REQUIRED.
_______________________________________________________________
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM
LOCATION WITH TENANT.
PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT
PROVIDED DISHWASHER AT THIS LOCATION.
PLAN NOTES
AREA NOT IN CONTRACT ARCHITECTURAL PLAN
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT WINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL
PARTIAL HEIGHT WALL
WALL TO DECK WITH INSULATION
35
8" METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL
W1
W2
WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W3
W4
PARTIAL HEIGHT WALL
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 40";
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
N
0 2' 4' 8' 16'
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
GENERAL NOTES
NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
TYP.
A1 1 1
1
A21 1
2
A21 1
3
A21 1
4
W2
W2
W2 W2
W2
W2
W2
PARTIAL HEIGHT WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 10''-6";
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL;
SEE ELEVATION 2/A111 & RCP FOR MORE
INFORMATION
W4
W4
W4
W5
W3
A1 1 1
2
0 1' 2' 4'
ELEVATION - EXTERIOR OF FOCUS 109, 110 + 111
A111
2
W2
A211
6
W5
PARTIAL HEIGHT WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 9''-5";
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL;
SEE ELEVATION 2/A111 & RCP FOR MORE
INFORMATION
05/03/18
Nick Mishler
LEGEND
LIGHT FIXTURE,
FLUORESCENT
EXHAUST FAN
EMERGENCY LIGHT
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
AREA NOT IN CONTRACT
AREA OF WORK
05/03/18
Nick Mishler
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
N
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
LIFE SAFETY NOTES
L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE
EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET
ALL LOCAL AND STATE CODES.
GENERAL NOTES
0 4' 8' 16'
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT
EP
EX
LEGEND
FIRE EXTINGUISHER
EXIT SIGN
FE
EMERGENCY LIGHT
FE
AREA NOT IN CONTRACT
AREA OF WORK
TRAVEL DISTANCE
SCOPE OF WORK OFFICE REMODEL OF SHELL OFFICE SPACE
TOTAL BUILDING AREA
TOTAL PROJECT AREA
CHANGE OF OCCUPANCY CLASS?
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
NO
OCCUPANCY CLASSIFICATION B(USINESS)
GEN. OFFICE SF 100
NUMBER OF EXITS REQUIRED: 2 PROVIDED: 2
SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0
TOTAL AREA ON THE FLOOR
SF
SF/FLOOR X STORIES SF
SF
19,305 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
=
TOTAL OCCUPANTS IN PROJECT AREA 59
CODE SUMMARY
PREVIOUS USE OF SPACE B(USINESS)
ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978? NO
5,870
5,870
19,305 4 77,220
59
- LED EDGE LIT
BUILDING CONSTRUCTION TYPE II-B
BUSINESS
EX
EX
EX
EX
TRAVEL DISTANCE = 122'
BUSINESS
EP
05/03/18
Nick Mishler
TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM
WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE
FOR WIRING THE BASE PANELS OF THE WORKSTATIONS.
13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE
SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL
CONDUITS TO JUNCTION BOXES.
14. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN
EXISTING SPACES. CONSULT WITH LANDLORD.
15. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE
NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES.
16. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A.
REQUIREMENTS.
17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE
COVER PLATE.
18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS,
SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED.
19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.
EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES
SHOWN ON PLAN ARE FOR REFERENCE ONLY.
20. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY
SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM &
DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS
OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION.
FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR
EXPENSE.
21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION
DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE
WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS
(I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS).
MECHANICAL &
ELECTRICAL NOTES
1. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA
BUILDING CODE FOR CLASS A FIRE RATINGS.
2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM
ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS,
CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR
NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS
3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF
ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING
AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR
TO PURCHASING NEW.
4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH
COATS.
5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR
OPENINGS AS NOTED ON FINISH PLAN (I.E. WHERE VCT MEETS CARPET).
6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE
NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK.
PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING
OWNER.
7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED.
8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO
MATCH ADJACENT WALL FINISH.
9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT
DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL
MILLWORK.
10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH
INFORMATION.
11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.
12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT
MANUFACTURER.
FINISH NOTES
1. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE
PROVIDED UNDER THE GENERAL CONTRACT.
2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE
(A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.
3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE
TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION.
4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON
PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE
ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING
SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.
5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION
DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY
REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL
CONTRACTOR.
6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC
LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED.
BACKSPLASHES TO BE FIELD APPLIED.
7. EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC
LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED
OTHERWISE. IF PVC EDGING IS BEING PROPOSED BY FABRICATOR FOR EDGES OF
CABINETS AND DRAWERS, FABRICATOR MUST PROVIDE SAMPLE OF COLOR MATCHING
SPECIFIED PLASTIC LAMINATE FOR APPROVAL.
8. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS
(CUSTOM PLASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINETRY).
9. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND
CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.
MILL/CASEWORK NOTES
1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO
DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS.
2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS
DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD,
PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT
STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE
FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR
OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT
MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE
CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR
AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR
INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM.
3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING
THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE
ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF
WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS.
4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE
BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN
THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING
AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY
OWNER.
5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR
DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN.
VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION.
6. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS
REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING
CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING
FINISHES TO REMAIN.
7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED.
SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION.
8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID
INSTRUCTIONS.
9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO
REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION
EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE
CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY
SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE
BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE
OWNER'S USE IN THE PROJECT.
10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION)
REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING
BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES,
AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES.
REFER TO SECTION 300.21.
11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING,
MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE
CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND
GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL
TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN
"AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS.
12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING
OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,
DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.
DEMOLITION NOTES
T111 COVER SHEET AND GENERAL PROJECT NOTES
L100 LIFE SAFETY PLAN
D111 DEMOLITION PLAN
A111 ARCHITECTURAL FLOOR PLAN
A121 REFLECTED CEILING PLAN: HVAC / LIGHTING
A131 FINISH PLAN
A211 DOOR SCHEDULE / INTERIOR DETAILS
E111 ELECTRICAL PLAN
INDEX OF DRAWINGS
VICINITY MAP
NOT TO SCALE
COVER SHEET AND
GENERAL NOTES
T111
NOT TO SCALE
KEY PLAN - 1ST FLOOR
DATE DESCRIPTION
ISSUE
04.09.18 REVIEW SET
04.16.18 PERMIT SET
REVISONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
MEMBERCLICKS
MIDTOWN EAST - 1ST FLOOR
571 MONON BLVD, CARMEL, IN 46032
AS AS
2017.461
1ST FLOOR
1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING
CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE .
2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND
LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE
CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK.
3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE
DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS
OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR
WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS
OF THE SCOPE OF WORK.
4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL
CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS
PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS.
NOTED DIMENSIONS TAKE PRECEDENCE.
5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY
DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC.
6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL
ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS
STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL,
AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE
CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN
ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE.
7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING
HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING
HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND
WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS
OF ADJACENT TENANTS.
8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL
COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE
OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER
FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR
DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE
CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES.
9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH
APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY
SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION.
10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND
SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS,
SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR
MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES.
11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO
CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT.
12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR
STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING
CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES
SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED
BY CONSTRUCTION CREWS.
13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF
DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST
PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6
MIL VAPOR BARRIER ON EACH SIDE.
14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED
BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF
THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING
MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS
INDICATED ON THE CEILING PLAN).
15. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY,
PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT
OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE.
16. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS
INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC.
17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR
APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO
DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT
INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER.
18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT
TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF
MATERIALS AND EQUIPMENT.
19. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY
STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL
CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH
ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL,
MECHANICAL, AND ELECTRICAL CONSTRUCTION.
20. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY
SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER.
21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER
TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY
CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER
DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT.
22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING
MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT
ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED
AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED.
23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING
WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION
JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS.
24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH
DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE
FOR FINISH.
25. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS.
26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE
CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT
REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL
CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK.
27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR
INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT.
28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM
BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE
DRAWINGS. WRITTEN DIMENSIONS GOVERN.
29. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS.
REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING
STANDARD.
30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS
REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL
CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND
SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT
DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL
CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR
AGREEMENT.
31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH
APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.
32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED
PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE
DAMPERED IF REQUIRED.
33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN
INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON L100 IS BASED UPON AVAILABLE
INFORMATION AND FIELD VERIFICATION.
34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND
WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW
CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED.
1. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE
GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN,
INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE
SPRINKLER SYSTEM.
3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE,
THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND
REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE
SUPPRESSION SYSTEMS.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND
SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE
MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK.
FIRE PROTECTION NOTES
N
05/03/18
Nick Mishler