Loading...
HomeMy WebLinkAboutMemberClicks_PermitSet_041618DW DOCUMENT APPROVAL TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. ___________________________________ _____________________________________________ _____________________________________________ ___________ TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN-OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT. THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. GENERAL PROJECT NOTES 1. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO BASIC DESIGN-BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE DESIGN-BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL, ELECTRICAL AND PLUMBING DESIGN-BUILD CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-BUILD CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS. 2. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING OWNER/LANDLORD. 4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES AS REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. 5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. 9. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE G.F.C.I. 10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. 11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCHPLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE ENTRY 1 01 CAFE 1 06 DW x MEET 1 02 14'-1" 11'-10" OPEN OFFICE 1 07 TOWN HALL 1 05 x MEET 1 1 2 1 6'-5" 1 2'-7" x MEET 1 1 3 1 3'-9" 1 3'-7" COPY 1 08 x FOCUS 111 9'-6" 8'-0" x FOCUS 1 1 0 9'-6" 8'-0" STORAGE 1 04 96 SF IT 1 03 88 SF DEV OPEN OFFICE 1 1 4 x FOCUS 1 09 9'-6" 8'-0" ELN ELN ELN ELN ELN ELN FE FE LIFE SAFETY L100 LIFE SAFETY PLAN DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DEMOLITION PLAN DEMOLITION PLAN D111 DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR N 0 2' 4' 8' 16' ELECTRIC OUTLET(S) DATA OR COMMUNICATION OUTLET NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. EXISTING TO BE REMOVED EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WALL DOOR AND FRAME CEILING GRID AND TILES, 2'x4' SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' LIGHT FIXTURE, CAN LIGHT SWITCH LIGHT FIXTURE, FLUORESCENT, 2'x2' WINDOW / SIDELIGHT CEILING GRID AND TILES, 2'x2' LIGHT FIXTURE, TRACK LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT EXIT LIGHT WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT METAL STUD EXISTING WINDOW MULLION EQUAL ENTRY 101 CAFE 106 DW MEET 102 OPEN OFFICE 107 TOWN HALL 105 MEET 112 MEET 113 COPY 108 FOCUS 111 FOCUS 110 STORAGE 104 IT 103 DEV OPEN OFFICE 114 FOCUS 109 12'-9" 12'-2" 2'-6" 86° 86° 14'-1" 6'-5" 14'-5" 7'-01 2 " 6'-8 1 R R R R R R R R R R R R R R R R R R R R R R R R R S N S N S N R R R R R R NL NL NL NL NL SN SN SN S N S N3 S N3 ELN ELN ELN ELN ELN ELN 10'-6" 11'-0" 10'-6" 11'-0" 11'-0" 12-0" 12'-0" 82° 6'-2 1 2 " SN 4'-6" S NG EQ. EQ. SN REFLECTED ENTRY 101 CAFE 106 DW MEET 102 OPEN OFFICE 107 TOWN HALL 105 MEET 112 MEET 113 COPY 108 FOCUS 111 FOCUS 110 STORAGE 104 IT 103 DEV OPEN OFFICE 114 FOCUS 109 FINISH PLAN A131 CARPET FLOOR COVERINGS MFG: TBD ($28/SQ. YD. INSTALLED COST ALLOWANCE) TYPE: -- PATTERN: -- COLOR: -- CONCRETE EXISTING CONCRETE FLOOR TO BE SEALED AND POLISHED WALL BASE MFG: JOHNSONITE TYPE: 4" VINYL COVE, 1 8" GAUGE COLOR: -- PAINT / WALLCOVERING MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: -- FINISH: EGGSHELL MFG: TBD ($19.95/LINEAR YD. MATERIAL COST ALLOWANCE) TYPE: VINYL PATTERN: -- COLOR: -- PLASTIC LAMINATE / QUARTZ MFG: TBD COLOR: -- MISCELLANEOUS 3'-0" ADA (321 4" H) DISHWASHER BY TENANT 2'-0" 2'-8" REFRIG. BY TENANT 3'-3" (HOLD) 2'-10" 1 '-9" 2'-6" WALL CABINETS (SEE CASEWORK NOTE 1 ) SINGLE BOWL UNDER-MOUNT SINK: 18 GAUGE STAINLESS STEEL ELKAY 301 2"x18 1 2"x5 3 8" #ELUHAD281655 (OR EQUAL) WITH KOHLER SIMPLICE FAUCET #K-597-BL AND GARBAGE DISPOSAL 24" DEEP QUARTZ (QZ_) COUNTERTOP, EXTEND AT ANGLED PORTION OF WALL BASE CABINETS (SEE CASEWORK NOTE 1 ) OPEN ABOVE, EXPOSED TO DECK DRYWALL BULKHEAD, SEE DIMENSIONS ON REFLECTED CEILING PLAN 1'-11" ANGLED PORTION OF WALL FILLER PANEL AT ANGLED PORTION OF WALL TO MATCH CASEWORK AT BASE AND UPPER CABINETS EXTEND DRYFALL PAINT ON DECK ABOVE BEYOND EDGE OF BULKHEAD AS FAR BACK AS REQUIRED SUCH THAT ALL VISIBLE DECK AND COMPONENTS FROM EYE-LEVEL AT ANY POINT IN THE SPACE IS FINISHED WITH PT_. MICROWAVE BOX 2'-6" 1 '-31 2 " 1'-5" 3'-0" 1 '-6" (2) BUILT-IN FULL SIZE KEGERATORS WITH STAINLESS STEEL DOOR AND INTEGRATED DRAIN SYSTEM; TAP HANDLES AND DRIP TRAYS TO BE ENTRY 101 REFRIG BY TENANT CAFE 106 DW MEET 102 OPEN OFFICE 107 TOWN HALL 105 MEET 112 MEET 113 COPY 108 FOCUS 111 FOCUS 110 STORAGE 104 IT 103 DEV OPEN OFFICE 114 FOCUS 109 TV TV +60" +60" +48" +48" +44" +44" +44" J J J J J J +42" +42" GFCI GFCI +24" +60" +60" +60" +60" DED DED +44" +72" +72" +72" +72" ELECTRICAL PLAN E111 PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE OR MAGLOCK AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. NOT USED. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 24" A.F.F. PROVIDE POWER AND DATA AT HEIGHT NOTED ON PLAN FOR TENANT'S WALL MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH TENANT. PROVIDE POWER AT THIS LOCATION FOR TENANT'S DISHWASHER AND GARBAGE DISPOSAL. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA FOR TENANT'S WORKSTATIONS. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. PROVIDE FLUSH MOUNT FLOOR CORE WITH POWER AND DATA CENTERED IN ROOM WITH CONDUIT CONNECTION TO TENANT'S WALL MOUNTED TELEVISION. PLAN NOTES ELECTRICAL PLAN LEGEND DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR N 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN BOX, BLANK COVER PLATE BOX, OPEN POWER POLE FOR ELECTRICAL AND DATA. PROVIDE JUNCTION BOX ABOVE CEILING. POWER AND DATA POLE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE CEILING MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX J J B O J +42" AREA NOT IN CONTRACT AREA OF WORK 05/03/18 Nick Mishler INCORPORATED INTO COUNTERTOP PROVIDE (4) 32" LONG UNDER CABINET LIGHT FIXTURES, BRUCK WUNDERCAB, 138540LED-32-35K, CONTROLLED WITH SEPARATE SWITCH, INSTALLED AT BACK OF CABINET 2'-0" 2'-0" 2'-0" 2'-0" 3'-6" 2'-8" 2'-8" EXIST 4"V. EXIST 4"W. 2"W. F.F. 2"W. 2"W. SINK TO BUILDING DRAIN F.F. 11 2"V. CLG. 11 2"V. CLG. TO EXISTING STACK F1 F2 8'-2" 3'-0" 3'-4" 2" 2" 8'-0" 2" F3 7'-10" 2" 3'-0" 8'-2" 8'-0" 2" 2" 4'-4" 2" 3 8" TEMPERED GLASS 9'-6" 2" 3'-0" 8'-2" 8'-0" 2" 2" 6'-0" 2" 3 8" TEMPERED GLASS, BUTT-GLAZED 8'-0" D1 3'-0" 1'-0" 8" 7" 7" 8'-0" 3'-0" D2 D3 9'-0" 3'-0" 2'-6" 1 4" TEMPERED GLASS, WOOD FLUSH BEAD STAINED TO MATCH DOOR 4" STAINLESS STEEL TOP RAIL 1 /2" TEMPERED GLASS PROVIDE ONE PULL ON EACH SIDE OF EACH DOOR (TOTAL COUNT 4) AS NOTED IN REMARKS 4" STAINLESS STEEL BOTTOM RAIL 2'-6" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 1 '-9" 2'-6" WALL CABINETS (SEE CASEWORK NOTE 1 ) 25" DEEP QUARTZ (QZ_) COUNTERTOP WITH 4" HIGH BACKSPLASH BASE CABINETS (SEE CASEWORK NOTE 1 ) 4'-6" HOLD 1 '-6" 3'-0" OPEN BELOW 3'-6" 4'-0" X 11'-0" QUARTZ(QZ_) ISLAND AT 42"A.F.F. WITH MITER FOLD EDGE DETAIL AT CORNER SUCH THAT HORIZONTAL QUARTZ PATTERN TRANSITIONS TO VERTICAL DIRECTION AND EXTENDS TO FLOOR (NO VINYL BASE AT QUARTZ). ISLAND CENTERED ON WALL BELOW, PROVIDE CONCEALED/IN-WALL SUPPORTS AS REQUIRED. PARTIAL HEIGHT WALL BELOW, PAINTED (PT_) 1 1 '-0" BASE AS SCHEDULED 7" 7" 7" 1'-0" (TYP.) 3'-6" 7" 7" 1'-0" (TYP.) 7" 1 4" BIRCH VENEER PLYWOOD ON 1 4" MDF 6" METAL STUDS @ APPROX. 16" O.C. 1 4" ROUND-OVER, TOP AND BOTTOM EDGE 3 4" BIRCH VENEER UNFINISHED PLYWOOD 1 2 " 6" METAL STUDS @ APPROX. 16" O.C. LEDGER BOARD 4'-6" 12'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-0" SUPPORTING WALLS TO BE BUILT WITH 6" METAL STUDS, UNFINISHED BIRCH PLYWOOD SEATS TO BE BUILT IN SECTIONS AS REQUIRED; CONFIRM ANGLE AND EXACT DIMENSIONS IN FIELD PROVIDE CODE COMPLIANT POWDER COATED ALUMINUM HAND RAIL AS REQUIRED AT STEPS, FINISH: TBD PROVIDE CODE COPLIANT GUARD RAIL ALONG OPEN EDGE OF SEATING PER IBC 1013.2, FINISH: TBD NOTE: TOWN HALL SEATING OCCUPANT LOAD = 16 NUMBER OF OCCUPANTS BASED ON 18" WIDTH OF SPACE PER PERSON. ONE AISLE REQUIRED PER IBC TABLE 1021.2 DOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM. 01 3'-0"X9'-0" (PAIR) R2,R3 02 PS 03 SL, CL 04 SL, CL 09 PP, CL R3 10 PP, CL R3 11 PP, CL R3 12 PS 13 PS 14 R1 DOOR SCHEDULE INTERIOR DETAILS A211 TYPICAL ALL SINGLE LOCATIONS, GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF BASE CABINET PRIOR TO ORDERING. 1. PROVIDE A.W.I. CUSTOM GRADE, FLUSH-OVERLAY CABINETS. FABRICATE WITH PLASTIC LAMINATE (PL_) COVERED M.D.O. BOARD WITH MOCKETT ______ PULLS. COORDINATE WITH ELEVATIONS FOR QUANTITIES. - AT CAFE 106 PROVIDE: 24" DEEP COUNTERTOPS 23" DEEP BASE CABINETS 11 1 2" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS - AT COPY 108 PROVIDE: 25" DEEP COUNTERTOPS 24" DEEP BASE CABINETS 11 1 2" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS - 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS NOTED OTHERWISE. CASEWORK NOTES CL CLOSER CR CARD READER BY TENANT (N.I.C.) DL DUMMY LEVER EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT (N.I.C.) OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL - PROVIDE ONE ROCKWOOD POST MOUNT PULL ON EACH SIDE OF DOOR (TOTAL COUNT 2 AT EACH DOOR). PULL TO BE 20", CLEAR ANODIZED WITH SQUARE ENDS, RM3120-20 628. PS PASSAGE LATCHSET RL ROLLER LATCHES SL STOREROOM LOCKSET HARDWARE LEGEND NOTE: REFER TO FLOORPLAN AND CASEWORK ELEVATIONS FOR SINK LOCATIONS. DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR DOOR/FRAME TYPES 0 1' 2' 4' ELEVATION - CAFE 106 A211 3 NOT TO SCALE RISER DIAGRAM A211 1 EXISTING -- -- SEE REMARK -- -- CR, ES, SL, CL R1. FINISH TENANT SIDE OF DOOR AND FRAME TO MATCH SUITE STANDARD STAIN COLOR. FINISH CORRIDOR SIDE OF DOOR AND FRAME TO MATCH BUILDING STANDARD STAIN COLOR IN COMMON CORRIDOR. R2. CAP ENDS AND HEADER OF DRYWALL WRAPPED OPENING WITH ALUMINUM CASING. R3. PULLS TO BE ROCKWOOD 20" RM4020-US32D WITH HICKORY WOOD AND BACK TO BACK MOUNTING. 3'-0"x8'-0"x1 3 4" D2 SOLID CORE BIRCH VNR. STAIN TBD F3 TIMELY ALUMATONE REMARKS DOOR/FRAME NOTES 1. PROVIDE PREMIUM WHITE BIRCH VENEER, PLAIN SLICED, GRADE A PER WDMA I.S. #1-A BOOK MATCHED WHITE BIRCH WITH NO HEART WOOD, ONLY SAP WOOD (LIGHT COLORED WOOD). PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. TYPE MATERIAL FINISH TYPE MATERIAL FINISH D3 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING EL, CR, CL 3'-0"x8'-0"x1 3 4" D1 SOLID CORE BIRCH VNR. STAIN TBD F1 TIMELY ALUMATONE 3'-0"x8'-0"x1 3 4" D1 SOLID CORE BIRCH VNR. STAIN TBD F1 TIMELY ALUMATONE 3'-0"x8'-0"x1 3 4" D2 SOLID CORE BIRCH VNR. STAIN TBD F2 TIMELY ALUMATONE 3'-0"x8'-0"x1 3 4" D2 SOLID CORE BIRCH VNR. STAIN TBD F2 TIMELY ALUMATONE 3'-0"x8'-0"x1 3 4" D2 SOLID CORE BIRCH VNR. STAIN TBD F2 TIMELY ALUMATONE 3'-0"x8'-0"x1 3 4" D2 SOLID CORE BIRCH VNR. STAIN TBD F3 TIMELY ALUMATONE 3'-0"x8'-0"x1 3 4" D2 SOLID CORE BIRCH VNR. STAIN TBD F3 TIMELY ALUMATONE SEE REMARK 0 1' 2' 4' ELEVATION - COPY 108 A211 2 0 1' 2' 4' ELEVATION - CAFE 106 A211 4 7 TYP. SECTION THRU TOWN HALL SEATING A211 0 6" 1' 2' 0 3" 6" 1' 2' 5 TYPICAL SECTION THRU BENCH A211 A21 1 5 0 1' 2' 4' ENLARGED PLAN - TOWN HALL 105 A211 6 A21 1 7 05/03/18 Nick Mishler MFG: TBD COLOR: -- PATTERN: -- FINISH PLAN PLAN NOTES MFG: TBD COLOR: -- MFG: TBD COLOR: -- MFG: TBD COLOR: -- DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR N 0 2' 4' 8' 16' LEGEND MFG: TBD ($6/SQ. FT. INSTALLED COST ALLOWANCE) SIZE: -- PATTERN: -- COLOR: -- NOTE: PROVIDE SKIMCOAT OF ARDEX LEVELING LATEX AS NEEDED FOR SMOOTH SUBFLOOR THAT WILL NOT ALLOW FOR TELEGRAPHING OF IMPERFECTIONS IN THE FLOOR LUXURY VINYL TILE MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: -- FINISH: EGGSHELL MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: -- FINISH: EGGSHELL PROVIDE SCHLUTER SCHIENE TRANSITION STRIP AT FLOORING TRANSITION, FINISH: BRUSHED STAINLESS STEEL (EB). PROVIDE LEVELING LATEX UNDER CARPET AS SUCH THAT TOP OF FINISHES ARE LEVEL. SEAM SEAL CARPET EDGES. CONTRACTOR TO CONFIRM THAT TRANSITION PROFILE IS APPROPRIATE FOR FLOORING MATERIALS. PROVIDE JOHNSONITE SLIM LINE "J" PROFILE TRANSITION STRIP CTA-XXX-J AT CONCRETE FLOORING TRANSITION, COLOR: TBD. WALL FINISH AND VINYL BASE TO MATCH COMMON CORRIDOR BUILDING STANDARD; COORDINATE WITH LANDLORD. MFG: KRYLON TYPE: ACRYLIC DRYFALL COLOR: -- AREA NOT IN CONTRACT AREA OF WORK MFG: TBD ($28/SQ. YD. INSTALLED COST ALLOWANCE) TYPE: -- PATTERN: -- COLOR: -- A211 6 MFG: TBD ($15/SQ. FT. MATERIAL COST ALLOWANCE) TYPE: TILE PATTERN: -- COLOR: -- 05/03/18 Nick Mishler CEILING PLAN A121 CONTROL ENTRY, TOWN HALL, CAFE, COPY AND OPEN OFFICE LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. PROVIDE (4) 32" LONG UNDER CABINET LIGHT FIXTURES, BRUCK WUNDERCAB, 138540LED-32-35K, CONTROLLED WITH SEPARATE SWITCH. SEE ELEVATION FOR MORE INFORMATION. PROVIDE DRYWALL CEILING AT 10'-0" AFF AT THIS LOCATION. CEILING TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. WHERE APPLICABLE, TRANSITION FROM DRYWALL CEILING TO EXPOSED CEILING TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. CLEAN ALL EXPOSED SURFACES AND PREPARE FOR DRYFALL PAINT (PT4) PER MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. PROVIDE RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED IN THIS AREA. PORTION OF DRYWALL CEILING OUTSIDE OF FOCUS ROOM TO BE ANGLED. VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO DECK AT THIS LOCATION. SEE ELEVATION 2/A111 FOR MORE INFORMATION. EXPOSED CEILING ABOVE FOCUS ROOMS TO BE PAINTED WITH DRYFALL PAINT (PT4). NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. PROVIDE FLOATING DRYWALL CEILING AT 9'-0" AFF AT THIS LOCATION WITH 6" ARMSTRONG AXIOM TRIM AT EXPOSED EDGE. VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO DECK AT THIS LOCATION. EXTEND DRYFALL PAINT ON DECK ABOVE BEYOND EDGE OF BULKHEAD AS FAR BACK AS REQUIRED SUCH THAT ALL VISIBLE DECK AND COMPONENTS FROM EYE-LEVEL AT ANY POINT IN THE SPACE IS FINISHED WITH PT4. NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. DESIGN INTENT IS FOR ANGLE OF DRYWALL BULKHEAD TO ALIGN WITH WALL ANGLE AND FLOORING TRANSITION BELOW. PROVIDE DRYWALL CEILING AT 9'-0" AFF AT THIS LOCATION. CEILING TO BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. SEE ELEVATION 2/A111 FOR MORE INFORMATION. EXPOSED CEILING ABOVE FOCUS ROOMS TO BE PAINTED WITH DRYFALL PAINT (PT4). NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. DESIGN INTENT IS FOR SEAMLESS TRANSITION FROM HP-ID SUSPENDED FIXTURE TO HP-4 R RECESSED FIXTURE. TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 4" WIDE DRYWALL BULKHEAD EXTENDING FROM 9'-0" AFF TO EXPOSED CEILING. TRANSITION FROM DRYWALL CEILING TO EXPOSED CEILING TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL. 1. WHERE SHOWN, PROVIDE NEW 2'x2' 9 1 6" CEILING GRID AND 2'x2' FINE FISSURED REVEAL EDGE CEILING TILE (ARMSTRONG DUNE, OR SIMILAR). GRID TO BE INSTALLED AT 9'-0" AFF. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES PLAN NOTES SWITCH, PROJECTOR SCREEN LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH NP ND N N3 EXIT LIGHT FIXTURE, LED EDGE LIT LIGHT FIXTURE, 2'x2', LED, COLUMBIA LIGHTING - LCAT RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' AT 9'-0" AFF NIGHT LIGHT NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. NEW OR RELOCATED EXISTING TO REMAIN DIRECT PENDANT, LED, FINELITE HP-4-D, BOTTOM OF FIXTURES AT 9'-0" AFF, LENGTHS VARY, COORDINATE WITH ESL SPECTRUM, JENNIFER HALL 317.750.7221 jhall@esl-spectrum.com GYPSUM BOARD CEILING AT 9'-0" AFF LEGEND REFLECTED CEILING PLAN DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR N 0 2' 4' 8' 16' EMERGENCY LIGHT FIXTURE 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES A121 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) NG EXPOSED TO DECK AREA NOT IN CONTRACT AREA OF WORK RECESSED LIGHT FIXTURE, LED, FINELITE HP-4-R, LENGTHS VARY, COORDINATE WITH ESL SPECTRUM, JENNIFER HALL 317.750.7221 jhall@esl-spectrum.com R 2'-6" 05/03/18 Nick Mishler 4" 8'-4" CLEAR 4'-3" 10'-10" 15'-4 1 2" 9'-6" 98° 86° 8'-4" 8'-4" 8'-4" 9'-10" 1'-6" 12'-03 4 " 102° 94° 102° FE FE 2'-6" 102° 1'-11" 78° 82° 2'-21 2 " 17'-73 4 " 10'-6" 9'-0" EXPOSED DECK ABOVE FRONT EDGE OF 1 '-6" DEEP DRYWALL WING WALL; CONTINUOUS WITH BULKHEAD ABOVE FRONT EDGE OF 1 '-6" DEEP DRYWALL BULKHEAD; CONTINUOUS WITH WING WALL BELOW SEE DOOR SCHEDULE FOR DOOR AND FRAME DETAILS ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x 3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET AND FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE (5) 18" DEEP ADJUSTABLE WHITE MELAMINE SHELVES ON HEAVY DUTY K/V BRACKETS AND STANDARDS. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. COLUMN TO REMAIN EXPOSED AND UNFINISHED. PROVIDE CONCEALED/ IN-WALL SUPPORT BRACKETS AT PARTIAL HEIGHT WALL FOR ISLAND TOP AS REQUIRED. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT PROVIDED DISHWASHER AT THIS LOCATION. PLAN NOTES AREA NOT IN CONTRACT ARCHITECTURAL PLAN AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL WALL TO DECK WITH INSULATION 35 8" METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL W1 W2 WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W3 W4 PARTIAL HEIGHT WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 40"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR N 0 2' 4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. GENERAL NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 TYP. A1 1 1 1 A21 1 2 A21 1 3 A21 1 4 W2 W2 W2 W2 W2 W2 W2 PARTIAL HEIGHT WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 10''-6"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; FIBERGLASS SOUND BATT INSULATION INSIDE WALL; SEE ELEVATION 2/A111 & RCP FOR MORE INFORMATION W4 W4 W4 W5 W3 A1 1 1 2 0 1' 2' 4' ELEVATION - EXTERIOR OF FOCUS 109, 110 + 111 A111 2 W2 A211 6 W5 PARTIAL HEIGHT WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 9''-5"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; FIBERGLASS SOUND BATT INSULATION INSIDE WALL; SEE ELEVATION 2/A111 & RCP FOR MORE INFORMATION 05/03/18 Nick Mishler LEGEND LIGHT FIXTURE, FLUORESCENT EXHAUST FAN EMERGENCY LIGHT PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL AREA NOT IN CONTRACT AREA OF WORK 05/03/18 Nick Mishler DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR N 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. LIFE SAFETY NOTES L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. GENERAL NOTES 0 4' 8' 16' EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN FE EMERGENCY LIGHT FE AREA NOT IN CONTRACT AREA OF WORK TRAVEL DISTANCE SCOPE OF WORK OFFICE REMODEL OF SHELL OFFICE SPACE TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) GEN. OFFICE SF 100 NUMBER OF EXITS REQUIRED: 2 PROVIDED: 2 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 19,305 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A = TOTAL OCCUPANTS IN PROJECT AREA 59 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO 5,870 5,870 19,305 4 77,220 59 - LED EDGE LIT BUILDING CONSTRUCTION TYPE II-B BUSINESS EX EX EX EX TRAVEL DISTANCE = 122' BUSINESS EP 05/03/18 Nick Mishler TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. 13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES. 14. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES. CONSULT WITH LANDLORD. 15. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. 16. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS. 17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVER PLATE. 18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED. 19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 20. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS (I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS). MECHANICAL & ELECTRICAL NOTES 1. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS 3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW. 4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. 5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN (I.E. WHERE VCT MEETS CARPET). 6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. 8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION. 11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT. 12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. FINISH NOTES 1. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION. 4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. 6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. 7. EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE. IF PVC EDGING IS BEING PROPOSED BY FABRICATOR FOR EDGES OF CABINETS AND DRAWERS, FABRICATOR MUST PROVIDE SAMPLE OF COLOR MATCHING SPECIFIED PLASTIC LAMINATE FOR APPROVAL. 8. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS (CUSTOM PLASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINETRY). 9. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED. MILL/CASEWORK NOTES 1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS. 2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS. 4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION. 6. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. 7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. 8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID INSTRUCTIONS. 9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION) REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES. REFER TO SECTION 300.21. 11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN "AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS, DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY. DEMOLITION NOTES T111 COVER SHEET AND GENERAL PROJECT NOTES L100 LIFE SAFETY PLAN D111 DEMOLITION PLAN A111 ARCHITECTURAL FLOOR PLAN A121 REFLECTED CEILING PLAN: HVAC / LIGHTING A131 FINISH PLAN A211 DOOR SCHEDULE / INTERIOR DETAILS E111 ELECTRICAL PLAN INDEX OF DRAWINGS VICINITY MAP NOT TO SCALE COVER SHEET AND GENERAL NOTES T111 NOT TO SCALE KEY PLAN - 1ST FLOOR DATE DESCRIPTION ISSUE 04.09.18 REVIEW SET 04.16.18 PERMIT SET REVISONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY MEMBERCLICKS MIDTOWN EAST - 1ST FLOOR 571 MONON BLVD, CARMEL, IN 46032 AS AS 2017.461 1ST FLOOR 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE . 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. 3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. 5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC. 6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. 7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. 8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. 10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. 11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. 12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE. 14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 15. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. 16. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC. 17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 19. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 20. ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER. 21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. 23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 25. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK. 27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 29. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. 32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON L100 IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. 1. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. FIRE PROTECTION NOTES N 05/03/18 Nick Mishler