Loading...
HomeMy WebLinkAboutA101.0 Demolition PlanR 4 4 5 4 3 4 3 4 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 2 2 2 3 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 4 4 4 4 4 4 4 4 4 4 4 4 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 11 11 17 3' - 8" 40' - 0 1/4" 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 9 15 15 15 16 16 2 16 16 4" 3' - 4" 12' - 8 1/2" 3' - 4" 7' - 7 1/2" 2' - 7" 3' - 0 1/8" 16 16 16 2 2 16 11 11 11 11 11 11 11 11 11 15 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 3 15 1 16 1 1 1 7 7 20 20 2 3 3 3 2 21 21 21 21 21 21 21 21 22 21 21 21 21 21 21 21 21 21 21 22 22 21 21 21 21 22 19 2 13 14 18 18 21 1 1 1 1 1 1 1 1 1 1 1 1 1 15 15 15 3 3 3 3 23 16' - 5 1/2" +/- 9' - 3 1/2" +/- 24 25 24 24 26 26 6' - 0" 4' - 9" 7 1 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 A A B B C C D D E E F F G G H H J J K K 7.2 7.2 D.6 D.6 D.7 D.7 3 2 3 7 7'-8" CLR 8' - 5" 9 9 9 3 6 4 4 12 4 4 21 15 1 4 16 15 18 DEMOLITION LEGEND EXISTING WALL TO BE TO BE REMOVED COMPETE, INCLUDING ALL WALL PROTECTION, ELECTRICAL, DATA, NURSE CALL, AND SECURITY DEVICES. REFER TO MEP DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. EXISTING WALL TO REMAIN KEYED NOTE BY ROOM KEYED NOTES BY OBJECT 1 1 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 A A B B C C D D E E F F G G H H J J K K 7.2 7.2 D.6 D.6 D.7 D.7 6 6 DEMOLITION GENERAL NOTES 1 THESE PLANS SHOW/PROVIDE NOTATION FOR ARCHITECTURAL SCOPE ONLY. MEP SCOPE TO BE COORDINATED THROUGH THE CONSTRUCTION DOCUMENTS PHASE. COORDINATE FURTHER WITH ARCHITECT AND MEP CONSULTANT AS REQUIRED DURING THE DEMOLITION PROCESS. 2 NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS (A101, A102, A104 AND A105) BEFORE PROCEEDING WITH SELECTIVE DEMOLITION. 3 WALL DEMOLITION THAT INTERSECTS WITH EXISTING EXTERIOR WALLS/WINDOW SILLS/GLAZING NEEDS TO BE DONE IN A WAY TO MINIMIZE DAMAGE TO THE CONSTRUTION THAT REMAINS. PATCHING WILL BE REQUIRED TO MAINTAIN A CONSISTENT LEVEL OF FINISH IN THESE AREAS. TRUE NORTH arcDESIGN PROJECT NUMBER: DATE: DRAWING TITLE: DRAWING NUMBER: REVISIONS: DRAWN BY: CLIENT PROJECT NUMBER: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. 4/5/2018 2:23:13 PM C:\Users\kfunston\Documents\Revit 2017 Local\250 W 96th_firestone bldg_CENTRAL_kfunston.rvt ASCENSION | ST. VINCENT A101 DEMOLITION PLAN - FIRST FLOOR 15140A 03.06.2018 100% CONSTRUCTION DOCUMENTS 30029-INDIANAPOLIS - ST. VINCENT HEALTH ADMINISTRATION OFFICE 250 W. 96TH STREET - PARKWOOD BUILDING INDIANAPOLIS, IN 46260 AED ININD30029 3/32" = 1'-0" 6A DEMOLITION PLAN - FIRST FLOOR DEMOLITION PLAN NOTES 1 NO WORK IN THIS AREA 2 REMOVE EXISTING DOOR, FRAME, HARDWARE COMPLETE, AND GLAZING, IF APPLICABLE. 3 REMOVE EXISTING METAL STUD WALL IN ITS ENTIRETY INCLUDING ITEMS INSTALLED, ATTACHED, AND/OR OTHERWISE DEPENDENT ON WALL CONSTRUCTION. 4 REMOVE EXISTING CARPET, ADHESIVE, AND WALL BASE COMPLETE. PREPARE SURFACE TO RECEIVE NEW FINISH. COORDINATE ALL CARPET RECYCLING WITH MANNINGTON LOOP PROGRAM PRIOR TO DEMOLITION. CONTACT STEVE HADRYCH AT 714-585-1902 FOR FURTHER INFORMATION. 5 REMOVE EXISTING VCT FLOORING, ADHESIVE AND WALL BASE COMPLETE. PREPARE SURFACE TO RECEIVE NEW FINISH. 6 REMOVE EXISTING LAY-IN ACOUSTIC TILE CEILING SYSTEM COMPLETE INCLUDING ITEMS INSTALLED, ATTACHED, AND/OR OTHERWISE DEPENDENT ON WALL CONSTRUCTION. COORDINATE WITH MEP DEMOLITION SCOPE. 7 REMOVE PORTION OF WALL FOR NEW OPENING. 8 EXISTING CEILING TO REMAIN IN PLACE. REMOVE, SALVAGE, AND REPLACE CEILING PADS AS REQUIRED FOR MEP WORK ABOVE CEILING. 9 EXISTING COLUMN: PROTECT FROM DAMAGE UNTIL CONSTRUCTION IS COMPLETE. 10 EXISTING BULKHEAD TO REMAIN. 11 REMOVE EXISTING WALL FLUSH TO ADJACENT WALL. PATCH AS REQUIRED FOR A CONSISTENT FINISH APPEARANCE. 12 REMOVE EXISTING CASEWORK COMPLETE. 13 REMOVE AND SALVAGE ACCESS FLOORING COMPLETE IN THIS LOCATION. 14 POTENTIAL FLOOR MOUNTED SECURITY FEATURE IN THIS AREA. FURTHER DETAIL WILL BE PROVIDED IN NEW CONSTRUCTION DRAWINGS IN TERMS OF NECESSARY FLOOR PATCHING. 15 EXISTING WALL CONSTRUCTION TO REMAIN. PROTECT UNTIL CONSTRUCTION IS COMPLETE. 16 EXISTING DOOR, FRAME, AND HARDWARE TO REMAIN. PROTECT UNTIL CONSTRUCTION IS COMPLETE. 17 REMOVE RAMP AND HANDRAILS COMPLETE. PATCH/INFILL FLOOR AS NECESSARY TO RECEIVE NEW FINISHES. 18 REMOVE AND SALVAGE GLASS FURNITURE WALL FOR REINSTALLATION. 19 REMOVE EXISTING WALL. REMOVE, SALVAGE AND PROTECT EXISTING WALL END CAP ATTACHED TO MULLION FOR POSSIBLE FUTURE USE. PROTECT EXISTING ADJACENT WALL/SILL/GLAZING. PATCH AS REQUIRED FOR A CONSISTENT FINISH APPEARANCE. FURTHER DETAIL FOR SILL PATCH WILL BE PROVIDED IN NEW CONSTRUCTION DRAWINGS. 20 REMOVE PORTION OF WALL FOR OWNER PROVIDED STAINED GLASS WINDOW UNIT. PROVIDE ADEQUATE FRAMING AND HEADER AT THIS LOCATION. VERIFY EXACT DIMENSIONS OF WINDOW UNIT. FURTHER DETAIL WILL BE PROVIDED IN NEW CONSTRUCTION DRAWINGS. 21 HORIZONTAL BLINDS AND ALUMINUM WINDOW SILLS TO REMAIN WHERE INSTALLED, PROTECT UNTIL CONSTRUCTION IS COMPLETE. FUTURE PLAZAS/FORUMS/BOARDROOMS TO POTENTIALLY HAVE NEW WINDOW TREATMENTS, FURTHER DETAIL WILL BE PROVIDED IN NEW CONSTRUCTION DRAWINGS. 22 IN THE EVENT THE WINDOW UNIT IS BISECTED BY A WALL, EXISTING HORIZONTAL BLINDS TO REMAIN DURING INITIAL DEMOLITION PHASE. FURTHER DETAIL TO BE PROVIDED DURING NEW CONSTRUCTION. 23 PORTION OF EXISTING RAISED FLOOR TO REMAIN. PROTECT UNTIL CONSTRUCTION IS COMPLETE. 24 EXISTING FIRE EXTINGUISHER AND CABINET TO REMAIN. PROTECT UNTIL CONSTRUCTION IS COMPLETE. 25 REMOVE AND SALVAGE FIRE EXTINGUISHER AND CABINET FOR REUSE. PROTECT UNTIL CONSTRUCTION IS COMPLETE. 26 EXISTING ELECTRICAL EQUIPMENT TO REMAIN. PROTECT UNTIL CONSTRUCTION IS COMPLETE. 1/16" = 1'-0" 6D DEMOLITION REFLECTED CEILING PLAN - FIRST FLOOR 5 01.03.2018 ASI002 6 01.26.2018 PR03- FIRST FLOOR SOUTH 05/01/18 Nick Mishler