HomeMy WebLinkAboutE102.0 Lighting PlanATS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS
D OR
OR D
D OR
OR D
OS
OS
OS
OS
OS
OS
OS
PP
D
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F2 F2 F2 F2
F1
F1 F1
F1 F1
F1 F1
F1 F1
F1 F1
F1
F1
F1
F1
F1 F1
F1
F1
F1
F1
F1 F1
F1
F1
F1
F1
F1 F1
F1
F1
F1
F1
F1
F1
F1
F1 F1
F1
F1 F1 F1
F3 F3 F3 F3 F3 F3 F3
F1
F3
F3
F3
F3
F3
F1 F1
F1 F1
F1
F1
F1
F1
F3 F3 F3 F3 F3 F3
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F3 F3
F3 F3
F3 F3
F3 F3
F3 F3
F3
F3
F3
F3
F3
F3
F3
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F3
F3
F3
F3 F3 F3 F3 F3
F3
F3
F3
P1
F1
F1 F1 F1 F1
F1 F1 F1 F1
F3 F3 F3 F3 F3
F3
F3
F3
F3
F1 F1 F1
F1
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F1
F1
F1
F1
F1
F1
F1
F1
F1 F1
F1
F1 F1
F1 F1
F1
F1
F1
F1
F1
F1
F1 F1
F1 F1
F1 F1
F1
EXEM
EXEM EXEM EXEM
EXEM
EXEM F1
EXEM EXEM
EXEM
EXEM-2
EXEM
EXEM-2
EXEM
EXEM
EXEM
P1C
P1A
P1B
L1
H1
H1A
LCP
EM
EM
EM
EM EM
EM
EM
EM
EM
EM
EM
L1- 1
LCP R1-3
L1- 3
4
L1- 2
L1- 4
LCP R1-2
4
L1- 6
LCP R1-1
4
4
4
4
LCP R1-6
4
4 4
P1C- 2
LCP R1-5
L1- 5
LCP R1-7
L1- 5
LCP R1-4
4
4
L1- 7
F1
F1
F3
F2
DP-1
EM
F12
F12
L1- 5
L1- 5
5
9
9
9
9
L1- 7
EXEM
F1
F1
F1
F1
F1
10' - 0"
PDU-2- 2
L1- 1
F1 F1
F1
F1 F1
F1
F1
F1
L1- 3
6' - 0"
EQ EQ
L1- 9
P2
P2
P2
LCP R1-8
P1B- 26
LCP R1-9
F3 F3 F3
F3
F3
F3
F3
F3 F3
F3
F4-6 EM
F4-6
F4-6
F4-6
F4-6
2
F2 F2
F2
F2
L1- 5
F2
F2
LIGHTING PLANS -
GENERAL NOTES
01. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR EXACT PLACEMENT OF ALL LIGHTING FIXTURES.
VERIFY EXACT CEILING CONSTRUCTION WITH
ARCHITECTURAL REFLECTED CEILING PLANS AND
PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY
MOUNTING HARDWARE.
02. ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL
REQUIRED STRUCTURAL SUPPORTS AS REQUIRED BY
THE AHJ. THIS INCLUDES A MINIMUM OF (2) HANGER
WIRES SIMILAR TO CEILING GRID WIRES OR JACK CHAIN
AT OPPOSITE CORNERS OF ALL RECESSED FIXTURES
TO PROVIDE SUPPORT INDEPENDANT OF THE CEILING
GRID. RECESSED FIXTURES LOCATED IN A FIRE-RATED
CEILING OR WALL SHALL BE PROVIDED WITH A 5-SIDED
RATED ENCLOSURE MATCHING THAT OF THE CEILING
OR WALL RATINGS. THE ENCLOSURE SHALL MEET
CODE AND MANUFACTURER'S REQUIRED CLEARANCES.
03. ALL LIGHT FIXTURES MOUNTED INSIDE OF AN
ARCHITECTURAL COVE SHALL EXTEND THE FULL
LENGTH OF THE COVE. CONTRACTOR TO VERIFY THE
EXACT COVE LENGTH, ORDER QUANTITY OF FIXTURES,
AND PROVIDE TELESCOPING END UNITS AS REQUIRED.
04. WHERE RUNNING CIRCUITS THROUGH AN EXPOSED
CEILING, ALL WORK SHALL BE PARALLEL AND
PERPINDICULAR TO THE BUILDING FRAMING. ALL
CIRCUITS SHALL BE IN CONDUIT UNLESS OTHERWISE
APPROVED BY OWNER (SEE SPECIFICATIONS).
05. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL
BE PROVIDED WITH AN APPROVED FIRE STOP SYSTEM
EQUAL TO OR GREATER THAN THE FIRE RATING OF
THE WALL TO PREVENT THE SPREAD OF FIRE.
06. RACEWAYS ARE NOT PERMITTED TO SERVE AS AN EGC.
07. ANY AND ALL EXTERIOR WALL PENETRATIONS SHALL BE
PROPERLY SEALED AND WATERPROOFED TO PREVENT
THE ENTRANCE OF AIR OR WATER.
08. ALL LINEAR FLUORESCENT FIXTURES SHALL HAVE AN
INTEGRAL UL LISTED BALLAST DISCONNECT FOR
FUTURE SERVICING OF THE FIXTURE.
09. ALL EMERGENCY LIGHTING WITH INDIVIDUAL BATTERY
BACKUP SHALL BE FED FROM THE SAME CIRCUIT AS
THE LIGHTING IN THE AREA WHICH IT SERVES.
LIGHTING PLANS -
KEYED NOTES
LIGHTING CIRCUIT TO BE CONTROLLED VIA LIGHTING
CONTROL PANEL. REFER TO SCHEMATICS.
CEILING OCCUPANCY SENSOR. LOCATE AWAY FROM ANY
HVAC OR OTHER AIR MOVEMENT THAT MAY TRIGGER
FALSE SENSING.
WALL OCCUPANCY SENSOR. PROVIDE MANUAL "OFF"
CONTROL.
EMERGENCY EGRESS LUMINAIRE. ALL EMERGENCY UNITS
ARE TO BE CONNECTED TO THE CIRCUIT SERVING THE
GENERAL LIGHTING WHERE THE UNITS ARE LOCATED
AHEAD OF ANY SWITCHING.
TYPICAL SOUND MASKING SYSTEM EMITTER. COORDINATE
LOCATIONS WITH INSTALLER.
DIGITAL LIGHTING CONTROL MODULE. INTERFACE WITH
DIMMING RELAY PACKS USING CAT 5 CABLE. LUTRON
CAT.# nPOD GFX WH. REFER TO DETAIL 1 / E601 FOR WIRING
SCHEMATIC.
DIMMING POWER / RELAY PACK. CONNECT TO DIGITAL WALL
CONTROL AND TO OTHER DOWNSTREAM RELAY PACKS
USING CAT 5 CABLE. LUTRON CAT.# nPP16(D)
TYPICAL MULTI-SERVICE MC CABLE WITH 277 V CONDUCTORS
AND 0-10 V DIMMING CONDUCTORS. SOUTHWIRE MC-PCS Duo
OR EQUAL.
LIGHTING CONTROL OVERRIDE SWITCH LOCATION. REFER TO
WIRING SCHEMATICS.
1
2
3
4
5
6
7
8
ALL NOTES MAY NOT BE USED ON THIS SHEET
9
C
E
N
G
I
N
E
E
R
L
A
N
O
I
S
S
O
R
P
E
F
I
A
N
A
D
N
I
I
E
T
R
E
D
S
G
E
R
No.
PE11400027
STATE OF
A
A
M
E
R
O
N
T.
Y
A
M
A
S
H
I
T
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
TRUE
NORTH
DEEM PROJECT NUMBER:
DATE:
DRAWING TITLE:
DRAWING NUMBER:
REVISIONS:
DRAWN BY:
CLIENT PROJECT NUMBER:
201 N. Delaware Street, Suite B
Indianapolis, IN 46204
317.951.9192 T | 317.951.9194 F
www.arcdesign.us
This drawing and its contents are the property
of arcDESIGN P.C., and shall not be
reproduced in whole or in part by any means,
mechanical or electronic, without express
written permission of arcDESIGN.
CERTIFICATION:
4/2/2018 11:07:48 AM C:\Projects\CAD Files\17040 - St. Vincent - Firestone Bldg\40-Revit (ConDocs)\17040 - StVincent_Firestone_ELEC_17.rvt
ASCENSION | ST. VINCENT
E301
LIGHTING PLAN -
LEVEL 1
17040
09.22.2017
PERMIT SET
INDIANAPOIS - ST. VINCENT HEALTH
ADMINISTRATION OFFICE
250 W. 96TH STREET - PARKWOOD BUILDING
INDIANAPOLIS, IN 46260
B.C.D.
NORTH
E301 3/32" = 1'-0"
1 LIGHTING PLAN - LEVEL 1
1 2017.10.24 OWNER REVIEW
2 2017.11.15 CONSTRUCTION ISSUE
3 2017.11.28 REVISED CONSTRUCTION
ISSUE
4 2017.12.12 LIGHTING REVISIONS
13 2018.03.20 REVISED FLOOR PLAN
14 2018.03.27 REVISED FLOOR PLAN
3
4
4 4
4
4
13
13
13
14 14
05/01/18