Loading...
HomeMy WebLinkAboutE102.0 Lighting PlanATS OS OS OS OS OS OS OS OS OS OS OS OS OS OS OS OS OS OS D OR OR D D OR OR D OS OS OS OS OS OS OS PP D 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 A A B B C C D D E E F F G G H H J J K K F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F2 F2 F2 F2 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F3 F3 F3 F3 F3 F3 F3 F1 F3 F3 F3 F3 F3 F1 F1 F1 F1 F1 F1 F1 F1 F3 F3 F3 F3 F3 F3 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 P1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F3 F3 F3 F3 F3 F3 F3 F3 F3 F1 F1 F1 F1 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 EXEM EXEM EXEM EXEM EXEM EXEM F1 EXEM EXEM EXEM EXEM-2 EXEM EXEM-2 EXEM EXEM EXEM P1C P1A P1B L1 H1 H1A LCP EM EM EM EM EM EM EM EM EM EM EM L1- 1 LCP R1-3 L1- 3 4 L1- 2 L1- 4 LCP R1-2 4 L1- 6 LCP R1-1 4 4 4 4 LCP R1-6 4 4 4 P1C- 2 LCP R1-5 L1- 5 LCP R1-7 L1- 5 LCP R1-4 4 4 L1- 7 F1 F1 F3 F2 DP-1 EM F12 F12 L1- 5 L1- 5 5 9 9 9 9 L1- 7 EXEM F1 F1 F1 F1 F1 10' - 0" PDU-2- 2 L1- 1 F1 F1 F1 F1 F1 F1 F1 F1 L1- 3 6' - 0" EQ EQ L1- 9 P2 P2 P2 LCP R1-8 P1B- 26 LCP R1-9 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F4-6 EM F4-6 F4-6 F4-6 F4-6 2 F2 F2 F2 F2 L1- 5 F2 F2 LIGHTING PLANS - GENERAL NOTES 01. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT PLACEMENT OF ALL LIGHTING FIXTURES. VERIFY EXACT CEILING CONSTRUCTION WITH ARCHITECTURAL REFLECTED CEILING PLANS AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY MOUNTING HARDWARE. 02. ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIRED STRUCTURAL SUPPORTS AS REQUIRED BY THE AHJ. THIS INCLUDES A MINIMUM OF (2) HANGER WIRES SIMILAR TO CEILING GRID WIRES OR JACK CHAIN AT OPPOSITE CORNERS OF ALL RECESSED FIXTURES TO PROVIDE SUPPORT INDEPENDANT OF THE CEILING GRID. RECESSED FIXTURES LOCATED IN A FIRE-RATED CEILING OR WALL SHALL BE PROVIDED WITH A 5-SIDED RATED ENCLOSURE MATCHING THAT OF THE CEILING OR WALL RATINGS. THE ENCLOSURE SHALL MEET CODE AND MANUFACTURER'S REQUIRED CLEARANCES. 03. ALL LIGHT FIXTURES MOUNTED INSIDE OF AN ARCHITECTURAL COVE SHALL EXTEND THE FULL LENGTH OF THE COVE. CONTRACTOR TO VERIFY THE EXACT COVE LENGTH, ORDER QUANTITY OF FIXTURES, AND PROVIDE TELESCOPING END UNITS AS REQUIRED. 04. WHERE RUNNING CIRCUITS THROUGH AN EXPOSED CEILING, ALL WORK SHALL BE PARALLEL AND PERPINDICULAR TO THE BUILDING FRAMING. ALL CIRCUITS SHALL BE IN CONDUIT UNLESS OTHERWISE APPROVED BY OWNER (SEE SPECIFICATIONS). 05. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROVIDED WITH AN APPROVED FIRE STOP SYSTEM EQUAL TO OR GREATER THAN THE FIRE RATING OF THE WALL TO PREVENT THE SPREAD OF FIRE. 06. RACEWAYS ARE NOT PERMITTED TO SERVE AS AN EGC. 07. ANY AND ALL EXTERIOR WALL PENETRATIONS SHALL BE PROPERLY SEALED AND WATERPROOFED TO PREVENT THE ENTRANCE OF AIR OR WATER. 08. ALL LINEAR FLUORESCENT FIXTURES SHALL HAVE AN INTEGRAL UL LISTED BALLAST DISCONNECT FOR FUTURE SERVICING OF THE FIXTURE. 09. ALL EMERGENCY LIGHTING WITH INDIVIDUAL BATTERY BACKUP SHALL BE FED FROM THE SAME CIRCUIT AS THE LIGHTING IN THE AREA WHICH IT SERVES. LIGHTING PLANS - KEYED NOTES LIGHTING CIRCUIT TO BE CONTROLLED VIA LIGHTING CONTROL PANEL. REFER TO SCHEMATICS. CEILING OCCUPANCY SENSOR. LOCATE AWAY FROM ANY HVAC OR OTHER AIR MOVEMENT THAT MAY TRIGGER FALSE SENSING. WALL OCCUPANCY SENSOR. PROVIDE MANUAL "OFF" CONTROL. EMERGENCY EGRESS LUMINAIRE. ALL EMERGENCY UNITS ARE TO BE CONNECTED TO THE CIRCUIT SERVING THE GENERAL LIGHTING WHERE THE UNITS ARE LOCATED AHEAD OF ANY SWITCHING. TYPICAL SOUND MASKING SYSTEM EMITTER. COORDINATE LOCATIONS WITH INSTALLER. DIGITAL LIGHTING CONTROL MODULE. INTERFACE WITH DIMMING RELAY PACKS USING CAT 5 CABLE. LUTRON CAT.# nPOD GFX WH. REFER TO DETAIL 1 / E601 FOR WIRING SCHEMATIC. DIMMING POWER / RELAY PACK. CONNECT TO DIGITAL WALL CONTROL AND TO OTHER DOWNSTREAM RELAY PACKS USING CAT 5 CABLE. LUTRON CAT.# nPP16(D) TYPICAL MULTI-SERVICE MC CABLE WITH 277 V CONDUCTORS AND 0-10 V DIMMING CONDUCTORS. SOUTHWIRE MC-PCS Duo OR EQUAL. LIGHTING CONTROL OVERRIDE SWITCH LOCATION. REFER TO WIRING SCHEMATICS. 1 2 3 4 5 6 7 8 ALL NOTES MAY NOT BE USED ON THIS SHEET 9 C E N G I N E E R L A N O I S S O R P E F I A N A D N I I E T R E D S G E R No. PE11400027 STATE OF A A M E R O N T. Y A M A S H I T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TRUE NORTH DEEM PROJECT NUMBER: DATE: DRAWING TITLE: DRAWING NUMBER: REVISIONS: DRAWN BY: CLIENT PROJECT NUMBER: 201 N. Delaware Street, Suite B Indianapolis, IN 46204 317.951.9192 T | 317.951.9194 F www.arcdesign.us This drawing and its contents are the property of arcDESIGN P.C., and shall not be reproduced in whole or in part by any means, mechanical or electronic, without express written permission of arcDESIGN. CERTIFICATION: 4/2/2018 11:07:48 AM C:\Projects\CAD Files\17040 - St. Vincent - Firestone Bldg\40-Revit (ConDocs)\17040 - StVincent_Firestone_ELEC_17.rvt ASCENSION | ST. VINCENT E301 LIGHTING PLAN - LEVEL 1 17040 09.22.2017 PERMIT SET INDIANAPOIS - ST. VINCENT HEALTH ADMINISTRATION OFFICE 250 W. 96TH STREET - PARKWOOD BUILDING INDIANAPOLIS, IN 46260 B.C.D. NORTH E301 3/32" = 1'-0" 1 LIGHTING PLAN - LEVEL 1 1 2017.10.24 OWNER REVIEW 2 2017.11.15 CONSTRUCTION ISSUE 3 2017.11.28 REVISED CONSTRUCTION ISSUE 4 2017.12.12 LIGHTING REVISIONS 13 2018.03.20 REVISED FLOOR PLAN 14 2018.03.27 REVISED FLOOR PLAN 3 4 4 4 4 4 13 13 13 14 14 05/01/18 Nick Mishler