HomeMy WebLinkAbout04090044 Building PlansM ATT H EW EIGHT PARKWOOD SPECIFICATIONS AND GENERAL NOTES 0 CONTRACT CONDITIONS 0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION ARCHITECT: cso 280 E. 96TH STREET, SUITE L k INDIAN POLIS, INDIANA 46240 13171 848" 8PA 00 (317) 574.0957 FAX CONTRACTOR: 02 0.3 DI'I uk CONSTRUCTION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 462 0 PHONE: (317)808-6 00 INDEX OF (DRAWINGS APPROVED m & BAYM � MPItM m wm � ME= mm KEYPLAN SCALE: NOT TO SCALE NORTH 0.4 0.5 0.6 1.2 1.3 1.4 1.5 1.6 1.7 1.8 ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. GENERAL REQUIREMENTS WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURf?Y, FURNITURE AND "FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP, SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6' X 6' ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE, THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. LACY AM EY SUITE 135 INDIANAPOLIS, INDIANA RICHTER 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY OPERATING FOR TEN DAYS. .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOR THE VARIOUS SUBSTRATES, AS INDICATED. FOLLOWING: IMPERIAL CABINET CO., THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WITH NO DISTORTIONS. .1 INC. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL: .2 MERILLAT INDUSTRIES, INC. YORKTOWNE CABINETS PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. WIDTH NOT TO EXCEED 1/8 U.O.N. A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: .3 2 DEMOLITION 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC 15/16 MECHANICAL AND ELECTRICAL OUTLETS. LATEX PRIMER. 2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL. 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE 7 JOINT SEALERS 2. NON-FERROUS METAL: ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS 2.2 WORK. WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS AND FIXTURES: 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, .1 "DOW CORNING 786"; DOW CORNING CORP. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION .2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND .3 "863 #345 WHITE'; PECORA CORP. "PROGLAZE 3. FERROUS STRUCTURE: 15/16.2 ELECTRICAL SYSTEMS. GENERAL CONTRACTOR SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING ADJACENT .4 WHITE"; TREMCO CORP. "OMNIPLUS"; A. ACRYLIC DRY FOG FLAT FINISH: IS TO PROVIDE A COMPLETE PACKAGE OF DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, SURFACES, INCLUDING WITH REGARD TO MATERIALS AND .5 SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER MECHANICAL, AND WORKMANSHIP, ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED REDUCIBLE ACRYLIC DRY FOG COATING PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING SURFACES: 4. NON-FERROUS STRUCTURE: 15/16.3 CERTIFIED ENGINEER. IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED .1 "CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL .2 "AC -20'; PECORA CORP. REDUCIBLE ACRYLIC DRY FOG COATING. DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) BE INCLUDED. .3 "SONOLAC'; SONNEBORN BUILDING PRODUCTS 8. WOOD: AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE .4 "TREMCO ACRYLIC LATEX 834'; TREMCO, INC. A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND HI DRAWINGS. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX 15/16.4 OBTAIN WRITTEN CLARIFICATION PRIOR PROCEEDING WITH WORK.1. SUBMIT FIRE SPRINKLER 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE 8 DOORS AND WINDOWS PRIMER -SEALER. LAYOUT FOR COORDINATION /APPROVAL BY THE ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL. SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES. NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: 15/16.5 COORDINATE WITH OTHER CEILING COMPONENTS. DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED OTHERWISE, DOORS TO BE BUILDING STANDARD FINISH. 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN PASTE WOOD FILLER OPEN GRAIN WOODS). ( ) SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR NOTED TO BE REPAIRED. 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN 15/16.6 OWNER'S AGENT. OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS, 8.4 AND LOCKSETS. GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 ALKYD STAIN. 3. SEALER: 1 COAT #4900 WONDER WOODSEALER WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK IN SCOPE OF CONTRACT. 9 FINISHES 4. FINISH: 2 COATS 4600 WONDER WOODSTAIN # 15/16.7 EQUIPMENT. SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING ALKYD SATIN VARNISH. 10. GYPSUM WALLBOARD: 15/16.8 GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. DATA AND COMMUNICATION DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A. ACRYLIC LATEX SATIN ENAMEL FINISH: CABLES ARE PROVIDED BY OTHERS AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL ETC, CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT .1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX PRIMER -SEALER. COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE INSTALLATION SHALL OCCUR. 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY 9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE "X" TAPERED LATEX SATIN ENAMEL. 13. PRECAST CONCRETE: 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND A. LATEX TEXTURE COATING -SAND FINISW (WET AREAS) 15/16.10 OUTLETS, UNLESS OTHERWISE NOTED. ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. 1. PRIMER: 1 COAT 1504" WONDER -SHIELD ACRYLIC LATEX HOUSE PAINT PRIMER. COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX TEXTURE COATING. 15/16.11 IVORY. WHERE FLUOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL 2.11 RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET. PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA- 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND 9,11 SMOOTH, CLE AN AND 15/16.12 PROVIDING PROPER ACCESS TO RECEPTACLES. IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. FINISHING OF GYPSUM BOARD..__ WALLCOVERING: APPLY WALLCOVERING SECURE, WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 FOR SPECIFIC LOCATION. CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET 5 METAL FABRICATIONS 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH -IN" DAMAGED OR SOILED 11l ES. ACCEPTABLE. CONSTRUCTION. 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS .2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6' FROM OUTSIDE CORNERS. OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL GN GENERAL NOTES REQUIRED TO COMPLETE WORK. REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES 6 WOOD AND PLASTIC .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS GNA CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND 10.1 UNLESS NOTED OTHERWISE. ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO "AMBASSADOR" REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION BUILDING STANDARD, PROVIDE JL INDUSTRIES SERIES, PROCEEDING WITH CONSTRUCTION. GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 197. MOISTURE 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR SEMI RECESSED, DUO -PANEL, FIELD PAINTED. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: 6.2 CONTENT. PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE CASED OPENING UNLESS NOTED OTHERWISE. A TO FINISHED FACE OF GYPSUM BOARD. EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'. MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH C. TO TOP OF FINISHED FLOORS. D. TO BOTTOM OF FINISHED CEILINGS. 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND CARPET. PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH 9.6 RESILIENT FLOORING: GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING EXISTING CONSTRUCTION AND WALL TYPES. JURISDICTION. .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI STANDARDS. ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT GN.5 OTHERWISE. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR .2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, TO FABRICATION OF MULTIPLE UNITS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING 6.5 COUNTERS: HIGH PRESSURE DECORATIVE (AMINATE COMPLYING WITH ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. GN.6 WITH CONSTRUCTION. CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). 9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL FOR THE ARCHITECT'S OBSERVATION 110N ION WITH REGARD TO DESIGN INTENT. HOLES AND LEVELING, ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM NOT PROCEED WITH INSTALL OF STUDS WITHOUT THIS .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACE VARIATION OF 9' IN 10 FEET, NON -CUMULATIVE. GN] OBSERVATION. FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT SURFACES. 2 PROVIDE 2 DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT ELECTRICAL OR DATA OUTLET LOCATIONS. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON- CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. 6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4008 FOR STANDARDS: GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. FLAMMABILITY: ASTM 2859 GNA CLOSE -IN OF WALLS. SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: SURFACE BURNING: ASTM E84 SMOKE DENSITY: ASTM E662 PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE. PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL SOUND ABSORPTION: ASTM C423 PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED THICKNESS). FADE RESISTANCE: AATCC 16E TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. STATIC RESISTANCE: AATCC 134 WARRANTY: 10 YEARS GN.10 JUNCTION BOXES ARE NOT PERMITTED. ALL APPLIANCES NOTE"D ON ELEVATIONS SHALL BE SUPPLIED BY .3 CABINET' HARDWARE SCHEDULE: CONTRACTOR. 1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. .1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES" BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL. fi�vU1avlo'3 9/2/04 CSO 1#24169 DOOR SCHEDULE DOOR FRAME HARDWARE REMARKS SIZE Engine ring Interio 1/4" TEMPERED Lands Z w Z GLASS INSET Q z Q z �i cwa af O (n wcn 6th Street, Suite 200 ,Indiana 46240 317.848.7 FAX 317.5 00 4.0957 ®Copyright 2001 C O W m L = _ 0 Q Q UOMOn ���UD 0- O all w = Q J Q J II II II II II O Z !Y = F— : w M w __jNaUo 100A RECEPTION 3'-0" g'-0" 1 3/4" WD/GL D3 WD D3 L,S,CL,DB _ 1008 RECEPTION 3'-0" g'-0" 1 3/4" WOOD D2 WD D2 BY—PASS 101A CONFERENCE 3'-0" 9'-0" 1 3/4" WOOD -9+ WD -8.1- S,L SEE 1&3/A202 101B CONFERENCE 3'-0" 9'-0" 1 3/4" WOOD -9+ WD -144- S,L SEE 1&3/A202 102 OFFICE 3'-0" 9'-0" 1 3/4" WOOD D4 WD D4 S,L 103 OFFICE 3'-0" 9'-0" 1 3/4" WOOD D4 WD D4 L,S,DB,CL 06 WALL LEGEND: NOTES: _ _ = EXISTING CONSTRUCTION TO BE REMOVED EXISTING PARTITION TO REMAIN NEW WALL PARTITION r, W1 2-1/2 25 GAUGE METAL STUDS ®24"O.C. ter: WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2 2-1/2" 25 GAUGE METAL STUDS @24"O.C. M WITH 5/8" GYPSUM WALL BOARD EACH r7 SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. DOOR SCHEDULE NOTES 1. ALL DOORS ARE TO BE NEW BUILDING STANDARD SOLID WOOD. WOOD STAIN TO MATCH DESIGNER SAMPLE. 2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD AT ALL NEW DOORS. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. COORDINATE KEYING LOCKSETS WITH TENANT. 5. ALL DOOR FRAMES ARE TO 2" WOOD, STAIN TO MATCH DESIGNER SAMPLE. 6. FRONT DOOR TO SUITE, EXTERIOR STAIN TO MATCH BUILDING STANDARD AND INTERIOR SIDE STAIN TO MATCH DESIGNER SAMPLE. 2" WOOD FRAME F— U w z 0 � j U LEVER n HARDWARE 00 �Uj ZOO • O w D1 D2 DOOR ELEVATIONS SCALE: 1/4"=l'—O" " WOOD RAME —PASS RDWARE F- 2 c� w �z C w U 7) oCkf F— N Xz 0 0 D3 FRAMMEOD WITH 1" CLEAR BORDER 1/4" TEMPERED 3/4" WHITE MELAMINE SHELF 3/4" WHITE MELAMINE TRIM, 3/4"D WHITE MELAMINE END SUPPORTS (TYP. EACH END) 1-1/4" dia. CHROME ROD NOTE: WHERE SPAN EXCEEDS 4'-0" A CENTER SUPPORT BRACKET IS TO BE USED COAT ROD/SHELF DETAIL SCALE: 1/21#=1 P-Ofo )STED APLIQUE 1" CLEAR BORDER LEVER HARDWARE DENOTES AREA NOT IN CONTRACT NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE 2" WOOD FRAME F- 2 CSO Architecture Engine ring Interio 1/4" TEMPERED Lands pe Architecture Land S GLASS INSET or r e Office W/FROSTED APLIQUE 6th Street, Suite 200 ,Indiana 46240 317.848.7 FAX 317.5 00 4.0957 ®Copyright 2001 C O WITH 1" CLEAR BORDER V) N R O all LEVER 0 0 T Uj m' W N "" 0 HARDWARE � U U D4 REFLECTED CEILING LEGEND: 171- NEW 2' X 4' PARABOLIC FLUORESCENT FIXTURE, TO MATCH BUILDING STANDARD NEW 6" INCANDESCENT DOWNLIGHT FIXTURE TO MATCH BUILDING STANDARD. f NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE TO MATCH BUILDING STANDARD. NEW 2 X 2 LAY—IN GRID SUSPENSION SYSTEM NEW TWO WAY SWITCH Tp NEW DIMMER SWITCH T3 NEW THREE—WAY SWITCH NL NIGHTLIGHT LOCATION GENERAL CONSTRUCTION NOTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER- DO NOT SCALE DRAWINGS. B. PROVIDE FIRE TREATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. E. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. F. ALL WALLS SHALL BE CHAULKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION G. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS H. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. I. BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBUNDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION. J. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. CONSTRUCTION PLAN NOTES: FP1 ALIGN FINISHED FACES. FP2 NEW SEMI -RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. 6 PROVIDE COAT ROD AND SHELF; REFERENCE DETAIL 1/A201. 1/3 OF COAT CLOSET TO BE ADA COMPLIANT. FP4 PROVIDE 3/4" x 4' x 4' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD. PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH PHONE BOARD TO BE INSTALLED ABOVE COAT ROD SHELF IN TOP RIGHT CORNER FPs COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL. FPs NEW DOOR TO BE INSTALLED, REMOVE EXISTING CORRIDOR WALL AND PREP FOR NEW OPENING GENERAL CEILING NOTES: A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. F. 4X4 CEILING GRID MAINS ARE EXISTING. GC TO PROVIDE BUILDING STANDARD GRID AND BUILDING STANDARD LIGHTS THROUGHOUT. I. CEILING HEIGHT IS 10'-0" A.F.F. UNLESS OTHERWISE NOTED. CEILING PLAN NOTES: 8 PROVIDE 3—WAY SWITCHING FOR ALL CAN LIGHTING IN CONFERENCE ROOM. CAN LIGHTING TO BE ON A DIMMER SWITCH. cP2 PROVIDE TWO SWITCHES AT THIS LOCATION, ALL 2X4 FLUORESCENTS TO BE ON ONE SWITCH, AND ALL CANS TO BE ON A DIMMER SWITCH. cPs CEILING MOUNTED PROJECTOR PROVIDED BY TENANT, INSTALLED BY GC 8 RECESSED CEILING PROJECTION SCREEN, PROVIDED & INSTALLED BY GC. CONSTRUCTION PLAN SCALE: 1/8"=11-0" NORTH REFLECTED CEILING PLAN SCALE: 1/8"=V-0" NORTH puke REAL coRPORATIDN 600 ast 96th Street Suite 100 India apolis, IN 46240 Phone (317) 808-6000 Fax: (317) 808-6797 I r r I I I r I it CSO Architecture Engine ring Interio Lands pe Architecture Land S rveying or r e Office 280 East Indianapoli 6th Street, Suite 200 ,Indiana 46240 317.848.7 FAX 317.5 00 4.0957 ®Copyright 2001 C O V) N R O all Im T Uj m' W N "" 0 I � U U z Wa � J a = V 0 _ L0 z OC �' J i' w F__ W V W 75Q Ld W V) LIL =Q W CC V (0 Z a Q 06 0 J Ul ;? z O W W o V 00 Q z 0 V Certi. r o t r 20Q3� 1 Drawing umber: 201 Cf Sheets Duke Jo Number: A/E Job Number: 2 169 I r r I I I r I it 5 A202 3/4" WOOD PANEL STAINED MATCH DESIGNER TO SAMPLE 1/4" GLASS WINDOW WITH 2" WOOD FRAME AND SITTING IN 4" BASE. PROVIDE FROSTED FILM APPLIQUE W/ 1" BORDER. n E 2 n n n n 2'—On 1 1, 6n 1 2,-0„ 1" 1, 6„ 1 2,-0„ 2Z 3,-0„ 2" DUPLEX WALL OUTLET CARPET - NEW QUADRAPLEX WALL OUTLET (sD o 00 DEDICATED CIRCUIT OUTLET 17 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING) Q NEW / / o 1 / c 0 I 00 / / / /IV C� FAX 317. o o) 0 U) .5 Q) O d' ~ 4" WOOD BASE, STAIN TO MATCH BUILDING STANDARD CONFERENCE ROOM ELEVATION 2 SCALE: 1/2"=1'-0" 1 /d" M ACC witinnw SAINTED WALL CONFERENCE ROOM ELEVATION SCALE: 1/2'=l' -O" 3/4" WOOD PANEL BEYOND. PANEL OVERLAPS WINDOW MULLIONS AND BASE BY 1 ". 1/4" GLASS WINDOW SURROUNED IN 2" WOOD FRAME AND INSET IN 4" BASE. PROVIDE FROSTED FILM APPLIQUE W/ 1" BORDER. 1/2- THK X 4" TALL WOOD BASE - STAINED TO MATCH BUILDING STANDARD, WOOD PANEL/ SECTION SCALE: 3/4"=1'-0" WINDOW PAINTED WALL 3/4" WOOD PANEL STAINED TO MATCH DESIGNER SAMPLE 1/4" GLASS WINDOW WITH 2" WOOD FRAME AND SITTING IN 4" BASE. PROVIDE FROSTED FILM APPLIQUE % 1" BORDER. 1'-6" 1n 2'-0" 1„ \1-6- 1n 2'-0" 1„ 1'-6,r DUPLEX WALL OUTLET CARPET - NEW QUADRAPLEX WALL OUTLET (sD NEW DEDICATED CIRCUIT OUTLET 17 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING) Q NEW / / o 1 / c 0 I 00 STANDARD. / / Indianapo 317.848. s, Indiana 46240 00 FAX 317. 74.0957 @Copyright 2001 0 U) .5 Q) CONFERENCE ELEVATION SCALE: 1/2"= l '-0" 1/4" GLASS WINDOW WITH 2" WOOD FRAME AND SITTING IN 4" BASE. PROVIDE FROSTED FILM APP QUE W/ 1" BORDER. L� 4" WOOD BASE, STAIN TO MATCH BUILDING STANDARD. ROOM 5 A202 3/4" WOOD PANEL STAINED TO MATCH DESIGNER SAMPLE 2" 2'_0„ 1" 1r 1" 2r_0n DUPLEX WALL OUTLET CARPET - NEW QUADRAPLEX WALL OUTLET (sD NEW DEDICATED CIRCUIT OUTLET 17 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING) Q NEW FLOOR MOUNTED DUPLEX OUTLET o 1 / / / STANDARD. 96th Street, Suite 200 Indianapo 317.848. s, Indiana 46240 00 FAX 317. 74.0957 @Copyright 2001 0 CONFERENCE 4 ELEVATION A202 I SCALE: 1/2"=1'-0" PAINTED WALL PAINTED WALL 4" WOOD BASE, STAIN TO MATCH BUILDING STANDARD. ROOM GENERAL ELECTRICAL NOTES: A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT AT PHONE AND DATA LOCATIO S AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. B. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIABLE WITH TENANT EQUIPMENT. D. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED ® 18" A.F.F. UNLESS OTHERWISE NOTED. ELECTRICAL PLAN NOTES: U PRUVIUE UEUICAIEU POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. E2 PROVIDE DEDICATED POWER FOR CEILING MOUNTED PROJECTOR. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS AND EXACT LOCATION WITH TENANT EQUIPMENT. E3 VERIFY EXACT LOCATION OF FLOOR MOUNTED OUTLET AND TELEPHONE WITH FURNITURE VENDOR AND/OR TENANT. ELECTRICAL LEGEND: GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED TO MATCH DESINGER SAMPLE, UNLESS OTHERWISE NOTED. B. ALL DOOR FRAMES TO BE 2" WOOD FRAMES, STAIN TO MATCH DESIGNER SAMPLE. C. ALL WOOD TRIM TO BE FINISHED TO MATCH DESIGNER SAMPLE. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHEIVE A SMOOTH TRANSITION FROM FINISH TO FINISH F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. G. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS, IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. H. PAINT NEW PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL FINISH. I. G.C. TO SUBMIT STAINED AND OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVI W AND APPROVAL, BEFORE PROCEEDING WITH MILLWWORK FINISHING PROCESS. J. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. K. PAINT ALL EXPOSED METAL SURFACES (ie. GRILLS HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE. FINISH PLAN NOTES: F1 WINDOW TO HAVE FROSTED APPLIQUE APPLIED TO GLASS ON INTERIOR SIDE 1" CLEAR BORDER TO REMAIN AROUND APPLIQUE. FINISH LEGEND: FLOORCOVERINGS NEW DUPLEX WALL OUTLET CARPET - NEW QUADRAPLEX WALL OUTLET (sD NEW DEDICATED CIRCUIT OUTLET 17 NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING) Q NEW FLOOR MOUNTED DUPLEX OUTLET ® NEW FLOOR MOUNTED TELEPHONE OUTLET GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED TO MATCH DESINGER SAMPLE, UNLESS OTHERWISE NOTED. B. ALL DOOR FRAMES TO BE 2" WOOD FRAMES, STAIN TO MATCH DESIGNER SAMPLE. C. ALL WOOD TRIM TO BE FINISHED TO MATCH DESIGNER SAMPLE. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHEIVE A SMOOTH TRANSITION FROM FINISH TO FINISH F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. G. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS, IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. H. PAINT NEW PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL FINISH. I. G.C. TO SUBMIT STAINED AND OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVI W AND APPROVAL, BEFORE PROCEEDING WITH MILLWWORK FINISHING PROCESS. J. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. K. PAINT ALL EXPOSED METAL SURFACES (ie. GRILLS HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE. FINISH PLAN NOTES: F1 WINDOW TO HAVE FROSTED APPLIQUE APPLIED TO GLASS ON INTERIOR SIDE 1" CLEAR BORDER TO REMAIN AROUND APPLIQUE. FINISH LEGEND: FLOORCOVERINGS CARPET - DIRECT GLUE c1 MFG: J & J INDUSTRIES PATTERN: FLOORED 9143 COLOR: IMPRESSED 916 BASE S4" WOOD BASE STRAIGHT PROFILE. STAIN TO MATCH BUILDING STANDARD. PAINT P1 MFG: SHERWIN WILLIAMS COLOR: SW6207 RETREAT FINISH: EGGSHELL WOOD FINISH ws1 WOOD STAIN AND SPECIES TO MATCH DESIGNER SAMPLE ELECTRICAL PLAN SCALE: 1/811= i I-011 NORTH FINISH PLAN SCALE: 1 /8"=1'-0" NORTH Que CORPORATION 600 East 96th Street Suite 100 Indiaapolis, IN 46240 Phon : (317) 808-6000 Fax: (317) 808-6797 ■ CSO Archite aure Engine ring Interio *- Landsc ape Architecture Land E urveying CorDorj to Office 280 East 96th Street, Suite 200 Indianapo 317.848. s, Indiana 46240 00 FAX 317. 74.0957 @Copyright 2001 0 U) .5 Q) O d' ' O = Uj mW — aI= QJ o U s W U CO) W �z = 9 Q Q �Z Z LL Ld 0a 0:� V V) -' 0 Z S� a (,C)Z J a �o a JLIJ F -Z V Q WU W o W _ � J W a Certifi C °O1i � o lOQ3& } .q ATE OF !' v SNP '( ,•��� . Drawin Number: 202 f Sheets Duke Jw Number: A/E Joumber: 24169 r I I I r I I r