INDEX OF DRAWINGS.
•
6.7
COVER
PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
•
FURNISHINGS
A201
DEMOLITION, CONSTRUCTION &FINISH PLAN
•
PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY,
A201
REFLECTED CEILING AND ELECTRICAL PLAN
APPROVED AS SUBMITTED APPROVED AS NOTED 1:1 REJECTED
SIGNATURE DATE
COMPANY
3RD FLOOR
KEYPLAN
SCALE: NTS
NORTH
B_ EE3 Is ol 11_1-ER
HAMILTON CROSSING III SUITE 330 CARMEL, INDIANA
SPECIFICATIONS AND GENERAL NOTES
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
1
1.1
1.2
1.3
1.4
Mi
1.6
1.7
1.8
CONTRACT CONDITIONS
THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION,
ENTITLED 'GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF
THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE
RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED
AS FOLLOWS:
3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND
FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE
PROCEEDING WITH CONSTRUCTION.
3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE
RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES,
3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY
GOVERNMENTAL FEES, LICENSES AND INSPECTIONS.
3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING
ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND
WORKMANSHIP.
10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY
PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE
CONTRACTOR'S RESPONSIBILITY.
WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES,
RULES AND REGULATIONS.
ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD
QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF
THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION
IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED
PROJECT.
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE
SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND
WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE
SPECIFIED CAPACITIES OF THE EQUIPMENT.
WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS
ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING
JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL
GOVERN THE WORK.
NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE
SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN
DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT
CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY
OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S
INTERPRETATION.
INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
GENERAL REQUIREMENTS
WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS
WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR
BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT,
THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS
INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE
AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL
COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING,
AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE
WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR
REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS.
CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
WORKMANSHIP.
SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE
FOLLOWING ITEMS:
.1 METAL FABRICATIONS.
.2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS.
.3 DOORS, FRAMES AND HARDWARE.
.4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL
PANEL ).
.5 VCT FLOORING AND BASE ( COLOR SAMPLES ).
.6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ).
.7 PAINT ( 6' X 6" ON ACTUAL SURFACE ).
.8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ).
.9 SIGNAGE ( SAMPLE SIGN ).
.10 LIGHT FIXTURES ( CATALOG CUTS ).
TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES,
TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER
WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR
THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING
CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S
AGENT.
THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND
OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR
SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS,
TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT
EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE.
THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES
ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT
ADDITIONAL CHARGE TO THE PARTY AFFECTED.
THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS
CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS
TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS.
SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED,
SUBMIT THE FOLLOWING INFORMATION:
.1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF
PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES.
.2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED.
.3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL
CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO
ACCOMMODATE THE SUBSTITUTION.
.4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL
AFFECT THE CONTRACT SUM AND CONTRACT TIME
STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME
FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING.
THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR
HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE
BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN
REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS.
1.12
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
5
5.1
6
6.1
6.2
6.3
6.4
6.5
6.6
PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL
6.7
MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10
PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
12
FURNISHINGS
CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION
PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS.
PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY,
EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE
6.8
DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING,
REINSTALL SUCH ITEMS.
12.1
CASEWORK:
PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED
PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION
WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY
.1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT
.1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE
NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND
OPERATING FOR TEN DAYS.
SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD
FOLLOWING:
MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN
6.9
INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND
FOR THE VARIOUS SUBSTRATES, AS INDICATED.
.1 IMPERIAL CABINET CO., INC.
THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE
STRAIGHT WITH NO DISTORTIONS.
.2 MERILIAT INDUSTRIES, INC.
INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL
6.10
JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM
1. FERROUS METAL
.3 YORKTOWNE CABINETS
PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD.
WIDTH NOT TO EXCEED 1/8 U.O.N.
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
6.11
GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL
1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC
15/16
MECHANICAL AND ELECTRICAL
DEMOLITION
OUTLETS.
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
15/16.1
MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND
COORDINATE DEMOLITION WITH CONSTRUCTION PLAKS TO DETERMINE
7
JOINT SEALERS
SEMI -GLOSS ENAMEL
ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE
EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE
2. NON-FERROUS METAL
RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS
BONDING/PATCHING OF EXISTING CONSTRUCTION TC REMAIN WITH NEW
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC
WORK.
7.1
ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS
1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR
EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT,
AND FIXTURES:
.1 "DOW CORNING 786"; DOW CORNING CORP.
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC
BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE,
OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION
.2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO.
SEMI -GLOSS FINISH
INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND
TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND
.3 863 #345 WHITE"; PECORA CORP.
"PROGLAZE
3. FERROUS STRUCTURE:
15/16.2
ELECTRICAL SYSTEMS.
GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF
SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING
.4 WHITE'; TREMCO CORP.
"OMNIPLUS";
A. ACRYLIC DRY FOG FLAT FINISH:
DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
.5 SONNEBORN BUILDING PRODUCTS
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A
WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED
REDUCIBLE ACRYLIC DRY FOG COATING
CERTIFIED ENGINEER.
TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR
7.2
ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING
4. NON-FERROUS STRUCTURE:
15/16.3
IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S
ADDITIONAL WORK RELATED TO SUCH ACTIVITIES.
WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED
SURFACES:
.1 "CHEM -CALK 600'; BOSTIK CONSTRUCTION PRODUCTS DIV.
A ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS
MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL
.2 "AC -20"; PECORA CORP.
'SONOLAC';
REDUCIBLE ACRYLIC DRY FOG COATING.
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN)
AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL
BE INCLUDED.
REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE
.3 SONNEBORN BUILDING PRODUCTS
.4 "TREMCO ACRYLIC LATEX 834'; TREMCO, INC.
8. WOOD:
A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH:
DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND
DRAWINGS.
1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX
15/16.4
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK.
SUBMIT ARE SPRINKLER
ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE
8
DOORS AND WINDOWS
PRIMER -SEALER.
LAYOUT FOR COORDINATION/APPROVAL BY THE
OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT
ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL
FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND
8.1
INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS
SEMI -GLOSS ENAMEL
COORDINATE WITH OTHER CEILING COMPONENTS.
METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW
NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER.
B. STAIN -VARNISH RUBBED FINISH:
15/16.5
DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
FINISHES.
8.2
INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED
1. FILLER: 1 COAT #4800 WONDER WOODSTAIN
SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR
EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL
OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH.
PASTE WOOD FILLER (OPEN GRAIN WOODS).
OWNER'S AGENT.
REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR
8.3
DOOR HARDWARE: BUILDING STANDARD WITH ADA ELVER HANDLE LATCH
2. STAIN: 1 COAT #96XX WONDER WOODSTAIN
15/16.6
OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED
NOTED TO BE REPAIRED.
AND LOCKSETS.
ALKYD STAIN.
WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED.
SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS.
8.4
GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048
3. SEALER: 1 COAT #4900 WONDER WOODSEALER
VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED
REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS
REQUIREMENTS FOR HEAT -STRENGTHENED GLASS.
QUICK DRY SEALER.
EQUIPMENT.
REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK
4. FINISH: 2 COATS #4600 WONDER WOODSTAIN
15/16.7
SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE
IN SCOPE OF CONTRACT.
9
FINISHES
ALKYD SATIN VARNISH.
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING
10. GYPSUM WALLBOARD:
15/16.8
DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND
DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS
9.1
GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645.
A. ACRYLIC LATEX SATIN ENAMEL FINISH:
INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS
"ELIMINATOR"
1. PRIMER: 1 COAT #50801 WONDER TONES LATEX
COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND
SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT
.1 INSTALL TYPE HEAD TRACK AT WALLS TERMINATING
PRIMER -SEALER.
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS.
AT CEILING. USE PREFORMED OUTSIDE CORNERS.
2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC
INSTALLATION SHALL OCCUR.
CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES
"X"
LATEX SATIN ENAMEL
15/16.9
DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF
AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY
9.2
GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE TAPERED
13. PRECAST CONCRETE:
OUTLETS, UNLESS OTHERWISE NOTED.
SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE-
EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND
A LATEX TEXTURE COATING -SAND FINISH (WET AREAS)
15/16.10
ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED
JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE
1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC
COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE
CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO
WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS.
LATEX HOUSE PAINT PRIMER.
IVORY.
DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS
2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX
15/16.11
WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY
PLUMBING, HVAC, ELECTRICAL, AND ARE PROTECTION SYSTEMS.
.1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED
TEXTURE COATING.
SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL
CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A
INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH
PROVIDING PROPER ACCESS TO RECEPTACLES.
RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT' SET.
MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA-
15/16.12
IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT,
216 RECOMMENDED SPECIFICATION FOR THE APPLICATION ANDAN
9.11
WALLCOVERING: APPLY WAIICOVERING SECURE, SMOOTH, CLE AND
FOR SPECIFIC LOCATION.
SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE
FINISHING OF GYPSUM BOARD.
WITHOUT WRINKLES, GAPS OR OVERLAPS.
15/16.13
CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET
DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN.
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO
9.4
CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM
.1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT
OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN"
METAL FABRICATIONS
DAMAGED OR SOILED TILES.
ACCEPTABLE
CONSTRUCTION.
.2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6" FROM
PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED
.1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS
OUTSIDE CORNERS.
OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS
IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL
GN
GENERAL NOTES
REQUIRED TO COMPLETE WORK.
REFLECTED CEILING PLAN SHALL GOVERN. 10
SPECIALTIES
.2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN
GN.1
CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND
WOOD AND PLASTIC
LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 10.1
FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO
REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO
UNLESS NOTED OTHERWISE
BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR" SERIES,
PROCEEDING WITH CONSTRUCTION.
CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE 'CONSTRUCTION
SEMI RECESSED, DUO -PANEL, FIELD PAINTED.
GN.2
DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED:
GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE
9 5
INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR
CONTENT.
CASED OPENING UNLESS NOTED OTHERWISE.
A. TO FINISHED FACE OF GYPSUM BOARD.
PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS.
EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA
.1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET
C. TO TOP OF FINISHED FLOORS.
C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'.
MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH
D. TO BOTTOM OF FINISHED CEILINGS.
FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND
CARPET.
PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA
GN.3
SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH
9.6
RESILIENT FLOORING:
EXISTING CONSTRUCTION AND WALL TYPES.
CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING
GNA
TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED
JURISDICTION.
1 UNLESS OTHERWISE NOTED, LAY TIED FROM CENTER MARKS
OTHERWISE.
FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI
ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT
GN.5
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
STANDARDS.
OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO
LOCATIONS DIMENSIONS AND TYPES DOOR AND WINDOW LOCATIONS
AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER.
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
.1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR
.2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID
NOTIFY DESIGNER FOR WRITTEN CLARIRCA11ON PRIOR TO PROCEEDING
TO FABRICATION OF MULTIPLE UNITS.
BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING
WITH CONSTRUCTION.
ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS.
GN.6
CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT
COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH
FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT.
NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS).
9.7
USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM
OBSERVATION.
.1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL
SURFACE VARIATION OF %" IN 10 FEET, NON -CUMULATIVE.
GN.7
FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT
SURFACES.
LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
.2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE
FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0" NON-
ELECTRICAL OR DATA OUTLET LOCATIONS.
9.8
CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING
CUMULATIVE. N011FY DESIGNER IF TOLERANCE IS EXCEEDED.
STANDARDS:
GN.8
CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO
CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4006 FOR
CLOSE -IN OF WALLS.
PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS.
FLAMMABILITY: ASTM 2859
GNA
SOUND INSULATED AND ARE RATED PARTITIONING SHALL BE CAULKED AT
SURFACE BURNING: ASTM E84
PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE.
.1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS:
SMOKE DENSITY: ASTM E662
PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE.
GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28
SOUND ABSORPTION: ASTM C423
PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED
(0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL
FADE RESISTANCE: AATCC 16E
TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL
THICKNESS).
STATIC RESISTANCE: AATCC 134
JUNCTION BOXES ARE NOT PERMITTED.
.2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28.
WARRANTY: 10 YEARS
GNAO
ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY
.3 CABINET HARDWARE SCHEDULE:
CONTRACTOR.
.1 INSTALL BROADLOOM CARPET BY DIRECT GLUE.
.1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES"
BY GRASS OR EQUAL.
.2 PULLS: WIRE PROJECTING TYPE, DRILLING 4' ON CENTER,
#4483 OR EQUAL AS MANUFACTURED BY STANLEY.
.3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH
MINIMUM 8 LBS. PULL; If SP 45 OR SP 46 OR EQUAL AS
MANUFACTURED BY STANLEY.
.4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES
WITH POSITIVE STOP AND LOCKOUT POSITION, WITH
HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS
MANUFACTURED BY KNAPE & VOGT.
.5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF
SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION
MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED
SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT
OR EQUAL
STATE t .?' .
nrn�aa
9/01/04
CSO #24249
3RD FLOOR
DEMOLITION PLAN
SCALE: 1/8" = 1'-0" NORTH
GENERAL DEMOLITION NOTES:
A. DEMOLISH EXISTING WALLS THAT ARE SHOWN DASHED, BACK TO A POINT
WHEREAS A SMOOTH SURFACE REMAINS FOR INSTALLATION OF NEW FINISHES.
B. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED.
REFERENCE FINISH PLAN TO COORDINATE LOCATIONS OF NEW FINISHES.
3RD FLOOR
FINISH PLAN
SCALE: 1/8" = 1'-0" NORTH
GENERAL FINISH NOTES:
A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS.
B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD.
C. ALL WOOD TRIM TO BE FINISHED TO MATCH EXISTING STAIN.
D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF ARCHITECT.
SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW.
E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS
TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE
A SMOOTH TRANSITION FROM FINISH TO FINISH
F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE
FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING
INSTALLATION.
G. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS.
IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD.
H. EXISTING WOOD DOORS AND TRIM THAT ARE TO REMAIN ARE TO BE SANDED AND
TOUCHED—UP TO MATCH EXISTING STAIN.
I. PAINT ALL EXPOSED M AL .SURFACES (ie. GRILLS HEATERS, AND FIRE
EXTINGUISHER CABINETS TO MATCH ADJACENT SURFACE.
J. ALL CARPET AND THE WALLCOVERING ON THE NORTH WALL ARE TO REMAIN. EXISTING
FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE
TO THEIR ORIGINAL CONDITION.
DEMOLITION PLAN NOTES:
of REMOVE SECTION OF WALL FOR NEW SUITE OPENING, REFER TO CONTSRUCTION PLAN
DEMOLITION LEGEND:
EXISTING CONSTRUCTION TO BE REMOVED.
EXISTING PARTITION TO REMAIN.
DENOTES AREA NOT IN CONTRACT.
FINISH PLAN NOTES:
S INSTALL FINISHES IN SUITE ENTRY AREA TO MATCH EXISTING CORRIDOR FINISHES.
FINISH LEGEND:
FLOORCOVERINGS WALLCOVERING
Ex EXISTING CARPET TO REMAIN. qD EXISTING WALLCOVERING TO REMAIN.
BASE PAINT
SVINYL BASE —4" COVE BASE P1 MFG: PORTER
MANUFACTURER: VPI COLOR: NEUTRA, 6752-1
COLOR: 32, MILKWEED FINISH: EGGSHELL
PLASTIC LAMINATE
MANUFACTURER: WILSONART LAMINATE
COLOR: FASHION GREY, D381-60
FINISH: MATTE
LOCATION: 3/4 WALL CAP.
3RD FLOOR U
CONSTRUCTION PLAN
SCALE: 1/8" = 1'-0" NORTH
GENERAL CONSTRUCTION NOTES: CONSTRUCTION PLAN NOTES:
A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS
NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE
ARE TO BE VERIFIED BY DESIGNER— DO NOT SCALE DRAWINGS.
B. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN
ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A).
C. REFER TO CONSTRUCTION FLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES.
D. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL.
E. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION
F. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE
OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS
G. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL
BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES.
H. BUILDING OWNER TO PROVIDE MINIBLINDS WHERE NEEDED AT ALL PERIMETER
WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION.
I. ALL NEW FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE.
LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS
THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE
NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC
PURPOSES ONLY.
3RD FLOOR
ELECTRICAL/DATA PLAN
SCALE: 1/8" = 1'-0" NORTH
GENERAL ELECTRICAL NOTES:
(5 ALIGN FINISHED FACES.
9 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS
USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION
FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT
BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/A201.
9 PATCH HOLE IN COLUMN. PREP FOR NEW WALL FINISH.
9 NEW OR RELOCATED RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED
IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF.
WALL LEGEND:
NOTES: EXISTING PARTITION TO REMAIN
NEW WALL PARTITION
® NEW LOW WALL PARTITION
W1 2-1/2" 25 GAUGE METAL STUDS ®24"O.C.
WITH 5/8" GYPSUM WALL BOARD EACH SIDE. M
WALLS TO EXTEND TO UNDERSIDE OF CEILING.
W2 2-1/2" 25 GAUGE METAL STUDS @24-O.C.
WITH 5/8" GYPSUM WALL BOARD EACH M
SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE
2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE
CEILING AND INSIDE WALL. INSULATION TO EXTEND 2'-0" IN
BOTH DIRECTIONS FROM CENTER LINE OF WALL.
;q= _T
W3 NEW LOW WALL CONSTRUCTION TO BE 60" A.F.F.: M
2-1/2" 25 GAUGE METAL STUDS ®16"O.C. to
WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND
TO + 60" A.F.F. WITH 6" PLASTIC LAMINATE (PL1) CAP. PROVIDE KNEE BRACES AT
END OF WALL.
110 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE
ELECTRICAL LEGEND:
A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT
AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA
SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. p
B. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. E
C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL
REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT.
D. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO
COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING RE UIREMENTS WITH TENANT AND/OR
FURNITURE DEALERSHIP FOR SYSTEMS BASE FEED AND,
POWER POLES.
ELECTRICAL CONTRACTOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE.
E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS
AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH.
F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED ® 18" A.F.F.
UNLESS OTHERWISE NOTED.
NEW DUPLEX WALL OUTLET.
NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING).
DENOTES EXISTING OUTLET LOCATION.
3RD FLOOR
REFLECTED CEILING PLAN (�
SCALE: 1/8" NORTH
GENERAL CEILING NOTES:
A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED.
B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO
ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES
IN CLOSE PROXIMITY ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION.
C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY
DISCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH
CONSTRUCTION.
D. MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR
TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND
NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS,
EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO
COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE
BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER
TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR
TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS
FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING.
E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL
SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT
OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY
CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR
IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND
OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR
SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION
OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR AESTHETIC
REVIEW ONLY.
F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING.
GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION.
G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS,
LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED.
CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT
CONDITION AS TO NOT SHOW LINE OF DEMOLITION.
H. RE—USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT
FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED
FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED,
RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION.
I. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED.
CEILING PLAN NO ES:
8 TIE SUITE ENTRY AREA CEILING GRID INTO EXI TING CORRIDOR CEILING GRID.
REFLECTED CEILING LEGEND:
EXISTING 2' X 4' FLUORESCENT FIXTURI TO BE REMOVED.
DOOR SCHEDULE
EXISTING 2' X 4' FLUORESCENT FIXTURE-
TO REMAIN.
DOOR
NEW OR RELOCATED 2' X 4' FLUORESCENT
FIXTURE, TO MATCH
HARDWARE
REMARKS
BUILDING STANDARD.
I
NEW CEILING MTD. EXIT LIGHT W/
DUAL
DIRECTION INDICATION
II
-LITE, TO MATCH BUILDING STANDARD.
EXISTING 2 X 2 LAY -IN GRID SU
PENSION SYSTEM.
Q
NEW OR RELOCATED 2' X 2' FLUORESCENT
FIXTURE, TO MATCH
Z
BUILDING STANDARD
NEW TWO WAY SWITCH.
NL
NIGHTLIGHT LOCATION.
DOOR SCHEDULE
DOOR
FRAME
HARDWARE
REMARKS
SIZE
II
Z w
w
¢
z
Q
Z
Q
Z
"'
CDcto
cn ¢w m
�ov�ic)
Z m
wa_
vo
=
vw
wLIJ
O Z
2
F-
w
w_j
to cn m
A
CORRIDOR
3'-0"
8'-O"
1 3/4"
WOOD
-
HM
-
L,S,DB,CL
301A
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
-
HM
-
L,S
ELECTRONIC STRIP
301B
CLOSET
WOOD
-
HM
-
POCKET DOOR
302
OFFICE
3'-0"
8'-0"
1 3/4"
WOOD
-
HM
-
L,S
ELECTRONIC STRIP
DOOR SCHEDULE NOTES
1. ALL DOORS TO BE BUILDING STANDARD SOLID WOOD DOORS.
2. ALL DOOR FRAMES ARE TO BE BUILDING STANDARD HOLLOW METAL FRAMES, COLOR TO MATCH BUILDING STANDARD.
3. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD.
4. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION.
5. COORDINATE KEYING LOCKSETS WITH TENANT.
TYPICAL WALL TYPE PREFINISHED ALUMINUM RECEIVER
TRIM `GB350" — FASTEN AT WINDOW
SILL & SET IN A CONTINUOUS BEAD OF
TYPICAL AT ALL EXTERIOR ACOUSTICAL SEALANT. TRIM COLOR
WALLS— 5/8- TYPE X G.W.B. TO MATCH BLDG. WINDOW MULLIONS.FINISH BELOW EXISTING
NE
WINDOW SILL COVER %—BELOWF EXISTING WINDOW SILL COVER
METAL STUD
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
WINDOW MULLION
DETAIL
A201 j SCALE: NTS