Loading...
HomeMy WebLinkAbout04090046 Building PlansARCHITECT: CSO 280 E. 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (31 574.7869 FAX CONTRACTOR: mti Duke REALTY CORPORATION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX OF DRAWINGS. • 6.7 COVER PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR • FURNISHINGS A201 DEMOLITION, CONSTRUCTION &FINISH PLAN • PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, A201 REFLECTED CEILING AND ELECTRICAL PLAN APPROVED AS SUBMITTED APPROVED AS NOTED 1:1 REJECTED SIGNATURE DATE COMPANY 3RD FLOOR KEYPLAN SCALE: NTS NORTH B_ EE3 Is ol 11_1-ER HAMILTON CROSSING III SUITE 330 CARMEL, INDIANA SPECIFICATIONS AND GENERAL NOTES 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1 1.1 1.2 1.3 1.4 Mi 1.6 1.7 1.8 CONTRACT CONDITIONS THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED 'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. GENERAL REQUIREMENTS WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT, THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6' X 6" ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. 1.12 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 5 5.1 6 6.1 6.2 6.3 6.4 6.5 6.6 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. .1 IMPERIAL CABINET CO., INC. THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WITH NO DISTORTIONS. .2 MERILIAT INDUSTRIES, INC. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL .3 YORKTOWNE CABINETS PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. WIDTH NOT TO EXCEED 1/8 U.O.N. A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC 15/16 MECHANICAL AND ELECTRICAL DEMOLITION OUTLETS. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC 15/16.1 MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND COORDINATE DEMOLITION WITH CONSTRUCTION PLAKS TO DETERMINE 7 JOINT SEALERS SEMI -GLOSS ENAMEL ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE 2. NON-FERROUS METAL RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS BONDING/PATCHING OF EXISTING CONSTRUCTION TC REMAIN WITH NEW A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC WORK. 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, AND FIXTURES: .1 "DOW CORNING 786"; DOW CORNING CORP. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION .2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND .3 863 #345 WHITE"; PECORA CORP. "PROGLAZE 3. FERROUS STRUCTURE: 15/16.2 ELECTRICAL SYSTEMS. GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING .4 WHITE'; TREMCO CORP. "OMNIPLUS"; A. ACRYLIC DRY FOG FLAT FINISH: DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND .5 SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED REDUCIBLE ACRYLIC DRY FOG COATING CERTIFIED ENGINEER. TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED SURFACES: .1 "CHEM -CALK 600'; BOSTIK CONSTRUCTION PRODUCTS DIV. A ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL .2 "AC -20"; PECORA CORP. 'SONOLAC'; REDUCIBLE ACRYLIC DRY FOG COATING. DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL BE INCLUDED. REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE .3 SONNEBORN BUILDING PRODUCTS .4 "TREMCO ACRYLIC LATEX 834'; TREMCO, INC. 8. WOOD: A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND DRAWINGS. 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX 15/16.4 OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. SUBMIT ARE SPRINKLER ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE 8 DOORS AND WINDOWS PRIMER -SEALER. LAYOUT FOR COORDINATION/APPROVAL BY THE OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL COORDINATE WITH OTHER CEILING COMPONENTS. METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS FINISHES. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. PASTE WOOD FILLER (OPEN GRAIN WOODS). OWNER'S AGENT. REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA ELVER HANDLE LATCH 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED NOTED TO BE REPAIRED. AND LOCKSETS. ALKYD STAIN. WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT #4900 WONDER WOODSEALER VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. EQUIPMENT. REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE IN SCOPE OF CONTRACT. 9 FINISHES ALKYD SATIN VARNISH. GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING 10. GYPSUM WALLBOARD: 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A. ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS "ELIMINATOR" 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT .1 INSTALL TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC INSTALLATION SHALL OCCUR. CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES "X" LATEX SATIN ENAMEL 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY 9.2 GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE TAPERED 13. PRECAST CONCRETE: OUTLETS, UNLESS OTHERWISE NOTED. SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND A LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PRIMER. IVORY. DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY PLUMBING, HVAC, ELECTRICAL, AND ARE PROTECTION SYSTEMS. .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED TEXTURE COATING. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH PROVIDING PROPER ACCESS TO RECEPTACLES. RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT' SET. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA- 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION ANDAN 9.11 WALLCOVERING: APPLY WAIICOVERING SECURE, SMOOTH, CLE AND FOR SPECIFIC LOCATION. SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE FINISHING OF GYPSUM BOARD. WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN" METAL FABRICATIONS DAMAGED OR SOILED TILES. ACCEPTABLE CONSTRUCTION. .2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CORNERS AND 6" FROM PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS OUTSIDE CORNERS. OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL GN GENERAL NOTES REQUIRED TO COMPLETE WORK. REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND WOOD AND PLASTIC LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 10.1 FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO UNLESS NOTED OTHERWISE BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR" SERIES, PROCEEDING WITH CONSTRUCTION. CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE 'CONSTRUCTION SEMI RECESSED, DUO -PANEL, FIELD PAINTED. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE 9 5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CONTENT. CASED OPENING UNLESS NOTED OTHERWISE. A. TO FINISHED FACE OF GYPSUM BOARD. PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET C. TO TOP OF FINISHED FLOORS. C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'. MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH D. TO BOTTOM OF FINISHED CEILINGS. FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND CARPET. PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH 9.6 RESILIENT FLOORING: EXISTING CONSTRUCTION AND WALL TYPES. CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED JURISDICTION. 1 UNLESS OTHERWISE NOTED, LAY TIED FROM CENTER MARKS OTHERWISE. FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION STANDARDS. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO LOCATIONS DIMENSIONS AND TYPES DOOR AND WINDOW LOCATIONS AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR .2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID NOTIFY DESIGNER FOR WRITTEN CLARIRCA11ON PRIOR TO PROCEEDING TO FABRICATION OF MULTIPLE UNITS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING WITH CONSTRUCTION. ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). 9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM OBSERVATION. .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACE VARIATION OF %" IN 10 FEET, NON -CUMULATIVE. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT SURFACES. LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT .2 PROVIDE 2' DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0" NON- ELECTRICAL OR DATA OUTLET LOCATIONS. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING CUMULATIVE. N011FY DESIGNER IF TOLERANCE IS EXCEEDED. STANDARDS: GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4006 FOR CLOSE -IN OF WALLS. PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. FLAMMABILITY: ASTM 2859 GNA SOUND INSULATED AND ARE RATED PARTITIONING SHALL BE CAULKED AT SURFACE BURNING: ASTM E84 PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: SMOKE DENSITY: ASTM E662 PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 SOUND ABSORPTION: ASTM C423 PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL FADE RESISTANCE: AATCC 16E TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL THICKNESS). STATIC RESISTANCE: AATCC 134 JUNCTION BOXES ARE NOT PERMITTED. .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. WARRANTY: 10 YEARS GNAO ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY .3 CABINET HARDWARE SCHEDULE: CONTRACTOR. .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. .1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES" BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4' ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; If SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL STATE t .?' . nrn�aa 9/01/04 CSO #24249 3RD FLOOR DEMOLITION PLAN SCALE: 1/8" = 1'-0" NORTH GENERAL DEMOLITION NOTES: A. DEMOLISH EXISTING WALLS THAT ARE SHOWN DASHED, BACK TO A POINT WHEREAS A SMOOTH SURFACE REMAINS FOR INSTALLATION OF NEW FINISHES. B. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH PLAN TO COORDINATE LOCATIONS OF NEW FINISHES. 3RD FLOOR FINISH PLAN SCALE: 1/8" = 1'-0" NORTH GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS. B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD. C. ALL WOOD TRIM TO BE FINISHED TO MATCH EXISTING STAIN. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. G. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. H. EXISTING WOOD DOORS AND TRIM THAT ARE TO REMAIN ARE TO BE SANDED AND TOUCHED—UP TO MATCH EXISTING STAIN. I. PAINT ALL EXPOSED M AL .SURFACES (ie. GRILLS HEATERS, AND FIRE EXTINGUISHER CABINETS TO MATCH ADJACENT SURFACE. J. ALL CARPET AND THE WALLCOVERING ON THE NORTH WALL ARE TO REMAIN. EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. DEMOLITION PLAN NOTES: of REMOVE SECTION OF WALL FOR NEW SUITE OPENING, REFER TO CONTSRUCTION PLAN DEMOLITION LEGEND: EXISTING CONSTRUCTION TO BE REMOVED. EXISTING PARTITION TO REMAIN. DENOTES AREA NOT IN CONTRACT. FINISH PLAN NOTES: S INSTALL FINISHES IN SUITE ENTRY AREA TO MATCH EXISTING CORRIDOR FINISHES. FINISH LEGEND: FLOORCOVERINGS WALLCOVERING Ex EXISTING CARPET TO REMAIN. qD EXISTING WALLCOVERING TO REMAIN. BASE PAINT SVINYL BASE —4" COVE BASE P1 MFG: PORTER MANUFACTURER: VPI COLOR: NEUTRA, 6752-1 COLOR: 32, MILKWEED FINISH: EGGSHELL PLASTIC LAMINATE MANUFACTURER: WILSONART LAMINATE COLOR: FASHION GREY, D381-60 FINISH: MATTE LOCATION: 3/4 WALL CAP. 3RD FLOOR U CONSTRUCTION PLAN SCALE: 1/8" = 1'-0" NORTH GENERAL CONSTRUCTION NOTES: CONSTRUCTION PLAN NOTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER— DO NOT SCALE DRAWINGS. B. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). C. REFER TO CONSTRUCTION FLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. D. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. E. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION F. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS G. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. H. BUILDING OWNER TO PROVIDE MINIBLINDS WHERE NEEDED AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION. I. ALL NEW FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. 3RD FLOOR ELECTRICAL/DATA PLAN SCALE: 1/8" = 1'-0" NORTH GENERAL ELECTRICAL NOTES: (5 ALIGN FINISHED FACES. 9 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/A201. 9 PATCH HOLE IN COLUMN. PREP FOR NEW WALL FINISH. 9 NEW OR RELOCATED RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. WALL LEGEND: NOTES: EXISTING PARTITION TO REMAIN NEW WALL PARTITION ® NEW LOW WALL PARTITION W1 2-1/2" 25 GAUGE METAL STUDS ®24"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. M WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2 2-1/2" 25 GAUGE METAL STUDS @24-O.C. WITH 5/8" GYPSUM WALL BOARD EACH M SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2 1/2" SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL. INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. ;q= _T W3 NEW LOW WALL CONSTRUCTION TO BE 60" A.F.F.: M 2-1/2" 25 GAUGE METAL STUDS ®16"O.C. to WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO + 60" A.F.F. WITH 6" PLASTIC LAMINATE (PL1) CAP. PROVIDE KNEE BRACES AT END OF WALL. 110 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE ELECTRICAL LEGEND: A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. p B. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. E C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. D. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING RE UIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP FOR SYSTEMS BASE FEED AND, POWER POLES. ELECTRICAL CONTRACTOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH. F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED ® 18" A.F.F. UNLESS OTHERWISE NOTED. NEW DUPLEX WALL OUTLET. NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING). DENOTES EXISTING OUTLET LOCATION. 3RD FLOOR REFLECTED CEILING PLAN (� SCALE: 1/8" NORTH GENERAL CEILING NOTES: A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR AESTHETIC REVIEW ONLY. F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. H. RE—USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. I. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED. CEILING PLAN NO ES: 8 TIE SUITE ENTRY AREA CEILING GRID INTO EXI TING CORRIDOR CEILING GRID. REFLECTED CEILING LEGEND: EXISTING 2' X 4' FLUORESCENT FIXTURI TO BE REMOVED. DOOR SCHEDULE EXISTING 2' X 4' FLUORESCENT FIXTURE- TO REMAIN. DOOR NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE, TO MATCH HARDWARE REMARKS BUILDING STANDARD. I NEW CEILING MTD. EXIT LIGHT W/ DUAL DIRECTION INDICATION II -LITE, TO MATCH BUILDING STANDARD. EXISTING 2 X 2 LAY -IN GRID SU PENSION SYSTEM. Q NEW OR RELOCATED 2' X 2' FLUORESCENT FIXTURE, TO MATCH Z BUILDING STANDARD NEW TWO WAY SWITCH. NL NIGHTLIGHT LOCATION. DOOR SCHEDULE DOOR FRAME HARDWARE REMARKS SIZE II Z w w ¢ z Q Z Q Z "' CDcto cn ¢w m �ov�ic) Z m wa_ vo = vw wLIJ O Z 2 F- w w_j to cn m A CORRIDOR 3'-0" 8'-O" 1 3/4" WOOD - HM - L,S,DB,CL 301A OFFICE 3'-0" 8'-0" 1 3/4" WOOD - HM - L,S ELECTRONIC STRIP 301B CLOSET WOOD - HM - POCKET DOOR 302 OFFICE 3'-0" 8'-0" 1 3/4" WOOD - HM - L,S ELECTRONIC STRIP DOOR SCHEDULE NOTES 1. ALL DOORS TO BE BUILDING STANDARD SOLID WOOD DOORS. 2. ALL DOOR FRAMES ARE TO BE BUILDING STANDARD HOLLOW METAL FRAMES, COLOR TO MATCH BUILDING STANDARD. 3. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD. 4. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 5. COORDINATE KEYING LOCKSETS WITH TENANT. TYPICAL WALL TYPE PREFINISHED ALUMINUM RECEIVER TRIM `GB350" — FASTEN AT WINDOW SILL & SET IN A CONTINUOUS BEAD OF TYPICAL AT ALL EXTERIOR ACOUSTICAL SEALANT. TRIM COLOR WALLS— 5/8- TYPE X G.W.B. TO MATCH BLDG. WINDOW MULLIONS.FINISH BELOW EXISTING NE WINDOW SILL COVER %—BELOWF EXISTING WINDOW SILL COVER METAL STUD CONTINUOUS BEAD OF ACOUSTICAL SEALANT WINDOW MULLION DETAIL A201 j SCALE: NTS Duke REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:317 808-6000 Fax: 317) 808-6797