Loading...
HomeMy WebLinkAbout04090047 Building PlansNOT ALL MAY APPLY Ro 2X2 FLUORESCENT LIGHT FIXTURE ::: :::.;:i;::.:;: NEW CEILING GRID/TILE TO BE INSTALLED WITH ACRYLIC LENS REFER TO FINISH SCHEDULE 0 RECESSED INCANDESCENT FIXTURE WITH ALZAK REFLECTOR AND WHITE TRIM RING. GYPSUM BOARD CEILING o PROVIDE J -BOX AND POWER FOR OWNER PROVIDED PENDANT LIGHT. REFER TO ENGINEERING DRAWINGS O RECESSED INTERIOR SPEAKER, WALL OR CEILING MOUNTED. COORD. WITH TENANT. "SURF" INDICATES EXTERIOR SURFACE MOUNTED SPEAKER. ®COMBINATION EXHAUST FAN/LIGHT. FAN DUCTED TO EXTERIOR. REFER TO ENGINEERING DRAWINGS NOTE: REFER TO ENGINEERING DRAWINGS FOR ALL LOCATIONS AND SPECIFICTIONS OF LIFE SAFETY, LIGHTING, POWER AND HVAC. ®KEYED NOTE OFFICE ROOM TAG. REFER TO FINISH SCHEDULE REFER SHEET WHERE SHOWN.10 000 14-0 SEMI -RECESSED FIRE EXTINGUISHER AND F.E. CABINET TO BE PROVIDED/INSTALLED BY G.C. O DOOR TAG. REFER TO DOOR SCHEDULE O SURFACE MOUNTED FIRE EXTINGUISHER OWINDOW TAG. REFER TO WINDOW 7HEDULE F.E. TO BE PROVIDED/INSTALLED BY G.C. NEW DOOR. REFER TO DOOR SCHEDULE SECTION CUT. REFER TO APPROPRIATE SHEET 7 i HEE ® NEW WINDOW. REFER TO WINDOW SCHEDULE ELEVATION TAG. # REFER TO APPROPRIATE SHEET LADDER. REFER TO SECTIONS AND NOTES HEE -1 EXTERIOR HOSE BIB. ! ENLARGED PLAN. METAL STUD FRAMED WALL. REFER TO ! REFER TO APPROPRIATE SHEET SECTIONS FOR WIDTH AND GAUGE. x` ./ HEE BRICK VENEER. REFER TO ELEVATIONS FOR TYPES ELEVATION TARGET. FINISH FLOOR ® EIFS OVER SUBSTRATE. REFER TO = 100'-0" U.O.N. SECTIONS FOR WIDTH AND PROFILE. xxx FINISH TAG. REFER TO FINISH LEGEND AND SCHEDULE REVISION REINFORCED CMU WALL. REFER Lk_`(TO ELEVATIONS. # `^ J� PARTIAL HEIGHT REINFORCED CMU WALL. z REFER TO PLAN FOR TOP OF WALL ELEVATION, PLAN OR TRUE NORTH EXISTING CONSTRUCTION TO REMAIN EXISTING DOOR/FRAME TO REMAIN BATT INSULATION; WIDTH OF FRAMING U.O.N. J\X= _ _ _ =DEMOLITION OF EXISTING CONSTRUCTION 33 VARIES REFLECTED CEILING PLAN 1/4-- = 1 "-0" 1'-6" 1'-3" CI R_ CI R ENLARGED PLAN 1/2" = 1'-0" 6'-7" TO C.L. OF nFMlglNC.' Wei i ENLARGED PLAN KEYNOTES NOTE; DIMENSIONS ARE FROM FINISH FACE i OF WALL TO CENTERLINE OF FIXTURE. UON. SURFACE MOUNTED PAPER TOWEL DISPENSER UNIT. MOUNT SO DISPENSER 1 R OPENING IS AT 48" AFF. UNIT PROVIDED BY OWNER, GC TO INSTALL. OSURFACE MOUNTED SOAP DISPENSER. MOUNT VERTICALLY SO CENTERLINE OF CONTROL IS AT 44" AFF. PROVIDED BY OWNER, GC. TO INSTALL. OADA COMPLIANT WALL MOUNTED LAVATORY. PROVIDE PROTECTIVE COVER OVER SUPPLY AND WASTE LINES. REFER TO ENGINEERING DRAWINGS FOR SPECIFICATIONS. LAVATORY TO BE MOUNTED WITH RIM AT 34" AFF. OSURFACE MOUNTED MIRROR. MOUNT BOTTOM AT 40" AFF, CENTERED OVER SINK. 4 BOBRICK B-290 2436 OR EQUAL. OADA COMPLIANT FLOOR MOUNTED WATER CLOSET. REFER TO ENGINEERING DRAWINGS FOR SPECIFICATIONS. RIM HEIGHT TO BE AT 18" AFF. 1 1/2" DIA S.S. GRAB BARS WITH SNAP FLANGES. BOBRICK B-68137. MOUNT SO 6 O CENTERLINE IS AT 36" AFF. OSURFACE MOUNTED TOILET TISSUE DISPENSER. MOUNT ® 28" AFF TO TOP. MOUNT HORIZONTALLY AT 36" FROM FACE OF BACK WALL TO FRONT EDGE OF PAPER ROLL. PROVIDED BY OWNER, GC TO INSTALL. CD4" 4" FLOOR DRAIN WITH POLISHED BRONZE STRAINER. TAPER CONCRETE TO DRAIN AT SAWCUT AREA. REFER TO ENGINEERING DRAWINGS FOR SPECIFICATIONS. PROJECT SQUARE FOOTAGE: 1,315 SF PORTION OF SF ®UNCONCENTRATED ASSEMBLY CALCULATION: 676 SF PORTION OF SF AT KITCHEN CALCULATION: 639 SF OCCUPANCY CALCULATION: 676 @ 15 SF PER PERSON + 639 @ 200 SF PER PERSON = 48 OCCUPANTS NUMBER OF EXITS REQUIRED: ONE NUMBER PROVIDED: ONE FLOOR PLAN 1/4" = 1'-0" 1 � VICINITY MAP U PROJECT LOCATION I_____ -q C 0 0--0 J No. To SCALE GENERAL NOTES Y TEF �l l ,CE BLVD. NOT ALL MAY APPLY 0,,,'' - - _ 9 UNLESS NOTED OTHERWISE. , -I : >3 2 j .- TYPICAL. tr - -I...... ....................................... ... ............ � . . 1. .. ............. . . . . . . . . . , . . . . . . . . . . . . , . . . . . . . . .... � . .. . . . . . . I . . . I .. ................... I ................................. .................... ... .................... r....... ................. . . . . .. ............................, I . . � , . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I . . _..­.....­ .. .............. 11.1 � ........ - .... �... 1. I I I 3. PROVIDE FIRE RATED WOOD BLOCKING IN METAL STUD WALLS FOR ANY WALL SUPPETO >- = - 0..................... � I co m W Z ASSEMBLIES. °: O 0 U C.) 104 .4 ~Hu. U - 19, OL� .= s .- d8 LINES, AND SUPPORTING BRACKETS/BLOCKING FOR CEILING HUNG ITEMS. Z) U .........j ................. TO THE ARCHITECT FOR REVIEW, PRIOR TO ORDERING ANY PRODUCTS. THE CONTRACTOR SHAI.L � TOILET WAS - N 7. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS AND JOB j w NzuW��Q ;�M�0�=z CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED IN DRAWINGS SHALL BE BROUGHT TO THE ., i. w -2 'G . = U 8. CONTRACTOR SHALL NOT SCALE THE DRAWINGS. 9. CONTRACTOR SHALL MAKE REPAIRS TO ANY DAMAGE TO EXISTING CONSTRUCTION IN a o• � PREPARATION FOR NEW FINISHES. -OPEN IT IS DELIVERED TO THE SITE. COORDINATE WITH THE OWNER ON SCHEDULES AND ANY ITEMS TAT ARE NOT TO BE UNLOADED BY THE CONTRACTOR. I cel tzE tv� CJ 103 a, _, Yc 3 � ::) Uf_ 3 z n F - zeOu �° PREP U Q§ d�UwO~�• _.,a Q -i aU-ju'C- �zWoozU 0-a U t AREA P, r Uu v v w.�o_U '- boo G 'a :D R O C v O jj� %O 0 "- � - - 00 � Q d' 00 - �" Z aJ 0:= y„ U O., :: :::::.::::::::::::... 00 Z 105 - n p 03=- - .....DINING .................. . Z � P%.. - STORAGE x V ar � s-0� -1 LU •:•.•.•.AREA .......1...0.....1 .:.:.:.:.:.:.:.....:.:.:.:.:.:.:.:...:.:.:.:...:.:: 1. i Ln -- 7A t ad n 75 - iw a LL w O 33..... j ['n F.. I- m z o . . '. V) W OA Z o N � Z Y F- 0 0 n c J /� co 10'-0" AFF cites z W 0 .\'..... . 31 (49z 7 U U in _ "' . . y E � r � 14'-9" AFF O _ - O :.f.: = .: :.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:..:.:.:.:.:.:.: O - 33 - __\ ... ... %.:.: -...,..I.. • .... . . ..., :..:.:.:0: •:...., I ........................:.....................:::::::::::.: I VARIES • •: "" = _ _.............................I O :... .::.................................... ::::::.::::::::::::..................I....................... .:...... ...:.....:..:.:.:.:.:.:.I.%:,:,:.:.:.:.'.:,:.:.:.:.:.::.::..... ::::::::::::::::::::::...:................:........... ....................... ::.:.:.:,:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.: ................... . - =33 = .. •. ... ... .... .. . :;.,:..,:0 ................................. { :•:•:•:•:•:•:•:•:•:•:•:.:.:..:.:.,........:•:::•. . ... ................. •..:. . O ..............................O PAINT FACE OF BULKHEAD P-2 = I 12'-9" AFF _ 0 4..........:...... 100 ' • • DINING:::::::................................................. •..:.:.:.:.:.:.:.:.:.:.:.:.:.:::.::.:.:.:.:.:...:::::::.::. 10, SERV NG - AR AREA;•;•.:•;•,•.•.•;•:•,•'•'.'•'•'.'•'.'.'.'.'.'.'..'.'.'.'.._' ..... '........ ."....I.�.........." ..1............" ...::::::.....o.::I:.:.::.::::::::::::::::::;::::::::. ...."........ .. ......'.....* :::;::::::::: ; ::;:::; ................ ......................0......... ::::::::;:.:.:.:..:::..:.:..:.:.:.::.:.: 32 = I......'....1.I,.., .......I" :: j::::.::: 14'-9" AFF = O l ........�..'...... ................... . • .' ................" ....".*...... .I... .I....*.. .I.......I....." ................................................................. ....................................................... ...."............*......"...... .......". ...."......I. ..."....I.... ..."..I...... I... ......'....." ....,.*......* ..., .I.�...." ...."..........."............".I.........'"............I...I...."............"............*...."............".............".........I...' ....",.....I. ..I....., ..................................... ...........I .�......... .` 1 ............................... •..:.:... - -I - - O :• 0 ................................ . . � . . . . . . :;; . . . . . . . . . . . . . . . . . . . . . . . . . * * . . . I . . . . . . . I . - _ - O _ . I UA: ..................................................e :.0:: I - .A, 33 VARIES REFLECTED CEILING PLAN 1/4-- = 1 "-0" 1'-6" 1'-3" CI R_ CI R ENLARGED PLAN 1/2" = 1'-0" 6'-7" TO C.L. OF nFMlglNC.' Wei i ENLARGED PLAN KEYNOTES NOTE; DIMENSIONS ARE FROM FINISH FACE i OF WALL TO CENTERLINE OF FIXTURE. UON. SURFACE MOUNTED PAPER TOWEL DISPENSER UNIT. MOUNT SO DISPENSER 1 R OPENING IS AT 48" AFF. UNIT PROVIDED BY OWNER, GC TO INSTALL. OSURFACE MOUNTED SOAP DISPENSER. MOUNT VERTICALLY SO CENTERLINE OF CONTROL IS AT 44" AFF. PROVIDED BY OWNER, GC. TO INSTALL. OADA COMPLIANT WALL MOUNTED LAVATORY. PROVIDE PROTECTIVE COVER OVER SUPPLY AND WASTE LINES. REFER TO ENGINEERING DRAWINGS FOR SPECIFICATIONS. LAVATORY TO BE MOUNTED WITH RIM AT 34" AFF. OSURFACE MOUNTED MIRROR. MOUNT BOTTOM AT 40" AFF, CENTERED OVER SINK. 4 BOBRICK B-290 2436 OR EQUAL. OADA COMPLIANT FLOOR MOUNTED WATER CLOSET. REFER TO ENGINEERING DRAWINGS FOR SPECIFICATIONS. RIM HEIGHT TO BE AT 18" AFF. 1 1/2" DIA S.S. GRAB BARS WITH SNAP FLANGES. BOBRICK B-68137. MOUNT SO 6 O CENTERLINE IS AT 36" AFF. OSURFACE MOUNTED TOILET TISSUE DISPENSER. MOUNT ® 28" AFF TO TOP. MOUNT HORIZONTALLY AT 36" FROM FACE OF BACK WALL TO FRONT EDGE OF PAPER ROLL. PROVIDED BY OWNER, GC TO INSTALL. CD4" 4" FLOOR DRAIN WITH POLISHED BRONZE STRAINER. TAPER CONCRETE TO DRAIN AT SAWCUT AREA. REFER TO ENGINEERING DRAWINGS FOR SPECIFICATIONS. PROJECT SQUARE FOOTAGE: 1,315 SF PORTION OF SF ®UNCONCENTRATED ASSEMBLY CALCULATION: 676 SF PORTION OF SF AT KITCHEN CALCULATION: 639 SF OCCUPANCY CALCULATION: 676 @ 15 SF PER PERSON + 639 @ 200 SF PER PERSON = 48 OCCUPANTS NUMBER OF EXITS REQUIRED: ONE NUMBER PROVIDED: ONE FLOOR PLAN 1/4" = 1'-0" 1 � VICINITY MAP U PROJECT LOCATION I_____ -q C 0 0--0 J No. To SCALE GENERAL NOTES Y TEF �l l ,CE BLVD. NOT ALL MAY APPLY 0,,,'' 1. ALL DIMENSIONS SHOWN ARE TO FACE OF MASONRY OR FACE OF METAL STUD FRN %, N Z UNLESS NOTED OTHERWISE. , U z N 2. PROVIDE DEEP LEG TRACK AF ALL METAL STUD CONNECTIONS WITH STRUCTURE AB Ea >3 2 j .- TYPICAL. tr Lu H .� ) i' 3. PROVIDE FIRE RATED WOOD BLOCKING IN METAL STUD WALLS FOR ANY WALL SUPPETO >- ITEMS. 0 2 ©Z U 4. PROVIDE APPROVED FIRE RAZED STOPPING MATERIALS IN ANY OPENINGS IN FIRE RAU ro co m W Z ASSEMBLIES. °: O 0 U C.) QQ 5. ALL MATERIALS WHICH WILL BE LOCATED IN THE CEILING PLENUM SHALL BE RATED KOR" INSTALLATION, OR PROTECTED TO PROVIDE .4 ~Hu. U COMPLIANCE. THIS INCLUDES, BUT IS NOT LI E POWER AND LOW VOLTAGE WIRING, TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AN DN 19, OL� .= s .- d8 LINES, AND SUPPORTING BRACKETS/BLOCKING FOR CEILING HUNG ITEMS. Z) U 6. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISH MATERIALS TO BE USED ON TFIgpl*J4 TO THE ARCHITECT FOR REVIEW, PRIOR TO ORDERING ANY PRODUCTS. THE CONTRACTOR SHAI.L � BEAR SOLE RESPONSIBILITY FOR ANY MATERIALS ORDERED INCORRECTLY WHEN THAT MATERIAL WAS NOT REVIEWED BY THE ARCHITECT. N 7. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS AND JOB j w NzuW��Q ;�M�0�=z CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED IN DRAWINGS SHALL BE BROUGHT TO THE ., i. w -2 'G ATTENTION OF THE ARCHITECT IMMEDIATELY. = U 8. CONTRACTOR SHALL NOT SCALE THE DRAWINGS. 9. CONTRACTOR SHALL MAKE REPAIRS TO ANY DAMAGE TO EXISTING CONSTRUCTION IN a o• � PREPARATION FOR NEW FINISHES. 10. THE GENERAL CONTRACTOR SHALL UNLOAD AND SECURELY STORE OWNER'S EQUIPMENT A IT IS DELIVERED TO THE SITE. COORDINATE WITH THE OWNER ON SCHEDULES AND ANY ITEMS TAT ARE NOT TO BE UNLOADED BY THE CONTRACTOR. KEY NOTES 1. NEW PRE -FINISHED ALUMINUM STOREFRONT SYSTEM IN EXISTING OPENING. REFER TO 6/A1.2 AND 1/A1.3 FOR MORE INFORMATION. GC TO FIELD VERIFY ALL OPENING DIMENSIONS, AND PROVIDE ALL MATERIALS, ACCESSORIES, HARDWARE ANG SEALANTS FOR COMPLETE INSTALLATION. 2. GC TO POUR SLAB FOR "LEAVE OUT" PORTION OF FLOQR AND ANY NEW CUTS IN FLOOR. SLAB TO BE 4" CONCRETE REINF. WITH 6x6-W1.4xW1.4 WWF ON 6 MIL VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILE, REFER TO SHELL DRAWINGS FOR LOCATIONS OF CONTROL JOINTS. FINISH TO BE SMOOTH FOR EXPOSED INSTALLATION. 3. FINISH WALL TO ACHIEVE 1 HOUR RATING. REFER TO 4/A1.2 FOR DETAIL AND UL CLASSIFICATION. 4. FURR OUT EXT. WALLS WITH 1 5/8" METAL STUDS, 6 MIL VAPOR BARRIER AND 5/8" TYPE "X" GYP BOARD, FULL HEIGHT, 5. SEMI RECESSED FIRE EXTINGUISHER CABINET WITH 10# ABC EXTINGUISHER, MOUNT WITH TOP OF ROUGH OPENING AT 5'-4" AFF. 6. 3'-0" TALL 3 5/8" METAL STUDS AND 5/8" GYP BOARD PARTIAL HEIGHT WALL. PROVIDE 30" WIDE X 1 112" TALL COUNTER. FRONT EDGE OF COUNTER TO HAVE BULNOSE EDGE. (2) 1X18 ADJUSTABLE SHELVES BELOW COUNTER. SHELVES, STANDARDS AND COUNTER PROVIDED AND INSTALLED BY GC. FACE OF COUNTER TO BE 4" FROM FACE OF WALL. 7. 3 5/8" METAL STUD DECORATIVE COLUMN AND 5/8" GYP BOARD. REFER TO REFLECTED CEILING PLAN FOR BULKHEADS. COORDINATE WITH OWNER. 8. 24" SQUARE MOP SINK WITH WALL MOUNT FAUCET AND MOP HANGER. REFER 10 ENGINEERING DRAWINGS. PROVIDE FRP-1 ON WALLS FROM MOP SINK TO 6'-6" AFF. SEAL ALL JOINTS. 9, NEW WATER HEATER. MOUNT ON SHELF AT 8'-O" AFF. REFER TO ENGINEERING DRAWINGS. 10, 18" WIDE X 1 1/2" THK., PLASTIC LAMINATE BAR COUNTER. TOP OF COUNTER AT 42" AFF. PROVIDE 3" SQUARE TUBE STEEL SUPPORT LEGS, ANCHORED TO FLOOR, AT 38" OC. LEG FINISH TO MATCH ADJACENT STOREFRONT. COUNTER AND SUPPORTS PROVIDED AND INSTALLED BY GC. 11. RESIDENTIAL STYLE DISHWASHER, PROVIDED BY OWNER, INSTALLED BY GC. REFER TO ENGINEERING DRAWINGS FOR PLUMBING AND ELECTRCIAL REQUIREMENTS. 12. PROVIDE WATER LINE TO OWNER PROVIDED GOFFEE AND ESPRESSO MACHINES. ESPRESSO MACHINE TO HAVE UNDERCOUNTER WATER SOFTENER/FILTER. REFER TO ENGINEERING DRAWINGS. 13. WATER SUPPLY L NE TO WATER COOLED GELATO MACHINE. REFER TO ENGINEERING DRAWINGS. 14. OWNER PROVIDED EQUIPMENT. REFER TO ENGINEERING DRAWINGS FOR ANY PLUMBING OR ELECTRICAL REQUIREMENTS. GC TO PROVIDE CONNECTIONS IF REQUIRED. 15. 30" DEEP PLASTIC LAMINATE BASE CABINETS WITH PLASTIC LAMINATE COUNTER ABOVE. CABINETS PROVIDED BY OWNER, COUNTER PROVIDED AND INSTALLED BY GC. 16. 24" DEEP PLASTIC LAMINATE COUNTER WITH (2) 1X18 ADJUSTABLE SHELVES BELOW. COUNTER AND SHELVES PROVIDED AND INSTALLED BY GC. 17. (1) 1 X 12X 15' LONG MELAMINE SHELF, (1) 1X24X15' LONG MELAMINE SHELF AND (1) 1X24X19'-5" LONG MELAMINE SHELF ON 48" LONG HEAVY DUTY KV STANDARDS, PROVIDED AND INSTALLED BY GC. MOUNT SO LONG SHELF IS ABOVE DOOR. 18. 24" DEEP OPEN COUNTER. Pf OVIDE FULL SUPPORT AT EXPOSED END, ANDS PORT LEG AT MID LENGTH. CABINETS AND COUNTER PROVIDED BY OWNER AND INSTALLED BY GC. AT "SIM" CABINET TO BE 18" DEEP. 19. BOTTOM OF STOREFRONT TO B PRE -FINISHED ALUMINUM SPANDRAL PANELS. BOTH INTERIOR AND EXTERIOR SIDES ARE TO BE FINISHED. 20. THREE BAY SINK PROVIDED BY OWNER AND INSTALLED BY GC. REFER TO ENGINEERING DRAWINGS. 21. WALL CABINET PROVIDED BY OWNER AND INSTALLED BY GC. PROVIDE F.R. BL CKING IN WALL. 22. PROVIDE END SPLASH AT END F COUNTER, ADJACENT TO REFRIGERAT R. TOP OF SPLASH TO ALIGN WITH BACK SPLASH. END SPLASH TO EXTEND OUT TO FACE 0 COUNTER. MATCH COUNTER FINISH. 23. DIPPING WELL PROVIDED BY 0 NER, INSTALLED IN COUNTER BY GC. REFER TO ENGINEERING DRAWINGS. 24. UNDER COUNTER ICEMAKER PR VIDED BY OWNER. REFER TO ENGINEERING DRAWINGS. 25. (3) 1 X 12 MDF SHELVES, WRAPPED IN PL -2. SUPPORT ON KV 71 NARRO FACE STANDARDS AND 170 BRACKETS, ANA HROME FINISH, 3'-6" LONG. SHELVES AND BRACKETS PROVIDED AND INSTALLED BY GC. PROVIDE MIRROR BETWEEN STANDARDS. PROV DE CLEAR SEALANT AT ALL EDGES. REFER TO LEVATION FOR MOUNTING LOCATION. 26. 21 " TALL X 36" LONG X 1 " TH . PLASTIC LAMINATE WALL ON TOP OF COUNTER ALIGN WITH FRONT EDGE OF COUNTER. RA IUS EXPOSED CORNER 6". PROVIDED AND INSTALLED BY GC. 27. RESIDENTIAL ELECTRIC STOVE AIND CABINET MOUNTED MICROWAVE/EXHAUST FAN PROVIDED BY OWNER. EXHAUST FAN TO BE DUCTED TO EXTERIOR. REFER TO ENGINEERING CRAWINGS. 28. PRE -CAST CONCRETE COLUMNS AND BALUSTRADES, PROVIDED AND INSTALLED BY OWNER. 29. (1) 1 X 12X7' LONG MELAMINE S ELF AND (2) 1 X24X7' LONG MELAMINE SHELVE ON HEAVY DUTY KV STANDARDS, PROVIDED AND INSTALLED BY GC. 30. (4) 1 X24X6'-3" LONG MELAMINE SHELVES ON HEAVY DUTY KV STANDARDS, PRO IDED AND INSTALLED BY GC. MOUNT WITH BOT OM SHELF AT 36" AFF. 31. 5/8" GYP BOARD CEILING, SMOOTH, OVER USG DRYWALL SUSPENSION SYSTEM Dtl OR ' EQUAL. Q NO PENETRATIONS TO BE PERMITTED IN CEILING. ANY SPRINKLER HEADS MUT BE FULLY RECESSED AND COVERED WITH PAINTABLE COVER TRIM. 32. SAME AS 31 ABOVE, EXCEPT RE ER TO ENGINEERING DRAWINGS FOR PENETRATIONS IN CEILING. 33. BULKHEAD FORMED OUT OF GYP BOARD, LAYER AS REQUIRED TO FORM CURVE . MINIMUM TOTAL THICKNESS TO BE 5/ ". REFER TO PLANS FOR HEIGHTS. FLAT BULK EADS TO BE FINISHED IN 5/8" GYP BOARD. 34. NOT USED 35. NOT USED 36. SINK. REFER TO ENGINEERING RAWINGS FOR SPECIFICATIONS. I 1l, � - , ,_-a �., _--I' -----___ = ry � > abs QO M Lu �o 1: z N >� I-_ 3W m R �y Y a 0 U ZU�c20Z w Qm �g� ;; 3 � LuQit]UV� .= s .- v, ! � Z) U LLIu 2-Z03�� x � w w � � � w � 2 O Q � � N � j w NzuW��Q ;�M�0�=z N 00 ., i. w -2 'G - = U 0Q0�Qc a o• � � �N Q z F-ZWW3zu Z<o - I cel tzE tv� CJ QZc 00<cL 0 a, _, Yc 3 � ::) Uf_ 3 z n F - zeOu �° U Q§ d�UwO~�• _.,a Q -i aU-ju'C- �zWoozU 0-a U t F- J: P, r Uu v v w.�o_U '- boo G 'a :D R C v jj� %O 0 "- � / 00 � Q d' 00 �" Z aJ 0:= y„ U O., W 00 Z °` - n p 03=- M 0 Z � P%.. 0 x V ar � s-0� -1 LU . tom. i Ln J JM 7A t ad n 75 - iw a LL w O :l j ['n F.. I- m z o V) W OA Z o N � Z Y F- 0 0 n c J /� co cites z W 0 v (49z 7 U U in z luE cd w ct wq V) �: C-) � ao E �U = o W ,14 w P4 > sem. c3 � V a Uiv, O = .� y,, E U � E a U U O C.. 0 a a, r C 1 = ry � > abs QO M � �o V)� N m R �y Y u Qm �g� ;; 3 � .= s .- v, ! � a, U x � w ,n .� ca W a, N N ;y N 00 ., i. w -2 'G - -r' a o• � <- �N m � tzE tv� CJ z a, _, Yc 3 � m r- 'o aR- Z 3 z n F °.E�E _.,a a) -E 0-a t a, = O a=- M.0 P, r Uu v v '- boo G 'a :D R C v E- °� v O a) r 2 o -a •B J . ° V 4 a, �" aJ 0:= y„ U R� � � , A v - n 03=- __ `" x V ar � s-0� -1 �- o �= ,� 7A t ad n 75 - iw a � ��, = c :l Q � OA `� �'•i n c R cites zz v `_` c w "' . . y E � r � J J W � > M w M � �o V)� 0 w �i Qm �g� Ln Q �* W14 - C) � w ,n Ln N N � N 00 cc 40 rwft Lu IIIIIIIIIIIIIIIIIIIIIIIIIII (A - 0 0 1 rk > v q .'ll •. 4 C4 PA •. z • • .. ��..�.....a►' • U (3 Nw 'emo• 4>iw uj CC ,4 ld u IIIIIIIIIIIIIIIIIIIII a •>m z I= Oct o" 0 uj mi mi 16 liiiiiiiim U Lu <_ 1 4 cN cc mi q 4 qw u � u GEL04002 MARK TYPE SIZE MATERIAL FINISH RATING FRAME MATERIAL FINISH RATING HARDWARE HEAD DTL. JAMB DTL. REMARKS 100 2 3-6x8-0ALUM./GLASS J PRE -FIN. -- 6/A1.2 SIM ALUMINUM PRE -FIN. -- 1 HOLLOW o (-- FRAME Lo SCWD/ w STUD IN z C14 N \ \ Q °=00�L)I =0�"'~Q� ,,�/ LL 103 2 3-0x7-0 P-1 __ A HOLLOW MTL P-3 -- 3 UZ L)0 J 0 Z LL 2 V POPLAR d�Uw0~m dwwwLuzL • V) Lu Z OU u 104 1 3-0X7-0 SCWD/ P-1 __ A HOLLOW MTL P-3 -- 2 UNDERCUT DOOR 1" POPLAR V O 00 w J n m W S U W w V) SEE SCHEDULE TYPE I GYP BOARD CEILING AT 14'-9" AFF GYP BOARD BULKHEAD ON NORTH WALL (12'-9" AFF) REFER TO FLOOR PLAN COLUMN, P-2 DEMISING WALL. REFER TO 4/A1.2 FOR DETAIL PROVIDE TROWELED FINISH, PAINTED P-1 BASE B-2 w J 0 W 2 U w w V) �.. CORE WOOD DOOR SUBMIT SAMPLES TO ARCHITECT HARDWARE SET #1 HARDWARE SET #2 HARDWARE SET #3 4 HINGES W/ NR PINS 3 HINGES 3 HINGES 1 ALUMINUM PUSH/PULL 1 THUMBTURN LOCKSET 1 PASSAGE SET 1 DEAD BOLT 3 MUTES 3 MUTES 1 CLOSER 1 CLOSER 2 KICKPLATES 34" X 6" 1 PERIMETER SEAL 2 KICKPLATES 34" X 6" 1 STOP 1 SWEEP 1 CLOSER 1 WALL STOP 1 THRESHOLD FINISH: US26D FINISH: TBD FINISH: TBD SEE SCHEDULE FINISHED ALUMINUM STOREFRONT DOOR WITH 1/4" TEMPERED GLASS TYPE 2 DOOR AND FRAME TYPES 1/2" = 1'-0" nll AAAA IIIIf1T11 rl" TYPE A METAL OR METAL STALLATION INTERIOR ELEVATION 1/2" = 1'-0" 2'-0" ALUCOBOND AT OPENING ADDITIONAL STRUCTURAL OF STOREFRONT TIRED =D ALUMINUM TUBULAR ;WITH BRACKETS AS REQ.) tE RESISTANT AWNING. f0 ELEVATION FOR COLOR. ALL SUPPORTS, I'S AND FRAMES TO BE COATED TO MATCH COLOR. SECTURE WITH ;TENERS. SEAL ALL kTIONS WITH CLEAR TYP. OF AWNING TO HAVE PED EDGE BRICK BEYOND ISHED ALUMINUM ONT SYSTEM ING OPENING HED ALUMINUM 'D SPANDRAL PANEL ON INTERIOR AND 2. MATCH STROEFRONT COLOR. PAVERS L a WALL TYPE 3 1 1/2" = 1'-0" TYP. BOTH SIDES OF WALL. 5/8" GYPSUM BOARD. EXTEND TO CEILING GRID LINE FRICTION FIT FULL DEPTH SOUND ATTENUATION BLANKET 3 5/8" 25 GA. METAL STUDS AT 16" OC. PROVIDE CHICAGO METALLIC ELIMINATOR TRACK AT CEILING/WALL INTERSECTION. 12'-4" +/- EXISTING R.O. 4" SHIM 12'-32 +/- FRAME EQUAL EQUAL 3'-6" GYP BOARD CEILING AT 14'-9" AFF LINE OF CEILING IN SERVING AREA BEYOND AT 12'-0" AFF. (C-1) 3'-6" X 1'-9" X 1" THK. PLASTIC LAMINATE SCREEN, FLUSH WITH FACE OF COUNTER, PL -2 3 5/8- STUDS 5/8" GYP. BOARDTAL FACEON EACH ICE b-1 WALL TYPE 2 1 1/2" - 1'-0" " SHIM EQUAL EQUAL TYP. BOTH SIDES OF WALL. 5/8" GYPSUM BOARD. EXTEND TO STRUCTURE ABOVE FRICTION FIT FULL DEPTH SOUND ATTENUATION BLANKET 3 5/8" 25 GA. METAL STUDS AT 16" OC. PROVIDE CONTINUOUS DEEP LEG TRACK AT TOP OF WALL/STRUCTURE INTERSECTION. AT "SIM" USE 6" 25 GA. STUDS TO CREATE WALL. rcSTOREFRONT ELEVATION 1/2" = 1'-0" 1 "X 1 " ALUMINUM MUNTINS, PRE -FINISHED. ATTACH TO EXTERIOR SIDE OF TEMPERED GLASS W/ 2 SIDE NEOPRENE TAPE HORIZONTAL MULLION AT STOREFRONT SECTION WITH DOOR ONLY. REFER TO 1/A1.3 1" INSULATED CLEAR GLASS IN PRE -FINISHED ALUMINUM STOREFRONT PREFINISHED ALUMINUM INSULATED SPANDRAL PANEL FINISHED ON INTERIOR AND EXTERIOR. MATCH STROEFRONT COLOR. T = TEMPERED GLASS 1 2 WALL TYPE 1 1 1/2" = 1'-0" WALL TYPE 4 1 1/2" = 1'-0" TYP. BOTH SIDES OF WALL. 5/8" GYPSUM BOARD. EXTEND TO CEILING GRID LINE 3 5/8" 25 GA. METAL STUDS AT 16" PROVIDE CHICAGO METALLIC ELIMINATOR TRACK AT CEILING/WALL INTERSECTION. TYP. BOTH SIDES OF WALL. 5/8" TYPE "X" GYPSUM BOARD. ATTACH GYP. BOARD WITH 1 1/4" TYPE "S" DRYWALL SCREWS AT 8" OC. AT EDGES AND 12" OC AT INTERMEDIATE STUDS. STOP GYP BOARD 1/2" FROM TOP OF WALL AND PROVIDE CONT. FIRE SAFE JOINTS. FILL WALL SOLID WITH SAFB INSULATION STUD PDEPTH I(N6S jLATION TO MATCH EXISTING 6" METAL STUDS AT 16" OC, INSTALLED BY BUILDING OWNER. VERIFY LOCATION OF WALL MATCHES PLAN, AND NOTIFY ARCHITECT OF ANY DISCRPANCI S. NOTE: WALL CONSTRUCTED TO ACHEIVE 1 HOUR FIRE RATING, PER UL LISTING. PROVIDE NECESSARY FIRE STOPPING MATERIAL AT ANY PENETRATIONS. (UL ASSEMBLY U465) GYP BOARD ON OPPOSITE SIDE OF DEMISING WAL S TO BE PROVIDED AND INSTALLED BY ADJACENT TENANT TIME OF THEIR BUILD OUT. BUILDING OWNER SHALLV RIFY THAT TOTAL WALL ASSEMBLY IS CONSTRUCTED AS SHOWN HEREIN. NOTE: COORDINATE WITH OWNER ON COLUMN DETAIL WHICH IS TO MATCH COLUMNS IN OWNER'S MURAL. INTERIOR ELEVATION 1/2" = 1'-0" EANDAD C0�8T GYP EBD., PD OF AIN ED L X 1 3/4" THK. TRIM WITH RAD. EDGE T. AND B. M SET AT ANGLE TO FLOOR PLAN TE 6 FOR INFORMATION. IN CONSTRUCTED OF METAL AND 5/8" GYP BD., P-2 L X 1 3/4" THK. TRIM WITH RAD. EDGE T. AND B. TRIM SET AT ANGLE 1/2" TRIM STOCK TRIM WITH G. EDGE QUARTER ROUND B-1 �,,.,.. ~ o C14- >� �W m m V cD Ln W W 2 w J 0 � c7�zQo3:Lu-- z Lu N g w HOLLOW o (-- FRAME Lo w STUD IN TYPE A METAL OR METAL STALLATION INTERIOR ELEVATION 1/2" = 1'-0" 2'-0" ALUCOBOND AT OPENING ADDITIONAL STRUCTURAL OF STOREFRONT TIRED =D ALUMINUM TUBULAR ;WITH BRACKETS AS REQ.) tE RESISTANT AWNING. f0 ELEVATION FOR COLOR. ALL SUPPORTS, I'S AND FRAMES TO BE COATED TO MATCH COLOR. SECTURE WITH ;TENERS. SEAL ALL kTIONS WITH CLEAR TYP. OF AWNING TO HAVE PED EDGE BRICK BEYOND ISHED ALUMINUM ONT SYSTEM ING OPENING HED ALUMINUM 'D SPANDRAL PANEL ON INTERIOR AND 2. MATCH STROEFRONT COLOR. PAVERS L a WALL TYPE 3 1 1/2" = 1'-0" TYP. BOTH SIDES OF WALL. 5/8" GYPSUM BOARD. EXTEND TO CEILING GRID LINE FRICTION FIT FULL DEPTH SOUND ATTENUATION BLANKET 3 5/8" 25 GA. METAL STUDS AT 16" OC. PROVIDE CHICAGO METALLIC ELIMINATOR TRACK AT CEILING/WALL INTERSECTION. 12'-4" +/- EXISTING R.O. 4" SHIM 12'-32 +/- FRAME EQUAL EQUAL 3'-6" GYP BOARD CEILING AT 14'-9" AFF LINE OF CEILING IN SERVING AREA BEYOND AT 12'-0" AFF. (C-1) 3'-6" X 1'-9" X 1" THK. PLASTIC LAMINATE SCREEN, FLUSH WITH FACE OF COUNTER, PL -2 3 5/8- STUDS 5/8" GYP. BOARDTAL FACEON EACH ICE b-1 WALL TYPE 2 1 1/2" - 1'-0" " SHIM EQUAL EQUAL TYP. BOTH SIDES OF WALL. 5/8" GYPSUM BOARD. EXTEND TO STRUCTURE ABOVE FRICTION FIT FULL DEPTH SOUND ATTENUATION BLANKET 3 5/8" 25 GA. METAL STUDS AT 16" OC. PROVIDE CONTINUOUS DEEP LEG TRACK AT TOP OF WALL/STRUCTURE INTERSECTION. AT "SIM" USE 6" 25 GA. STUDS TO CREATE WALL. rcSTOREFRONT ELEVATION 1/2" = 1'-0" 1 "X 1 " ALUMINUM MUNTINS, PRE -FINISHED. ATTACH TO EXTERIOR SIDE OF TEMPERED GLASS W/ 2 SIDE NEOPRENE TAPE HORIZONTAL MULLION AT STOREFRONT SECTION WITH DOOR ONLY. REFER TO 1/A1.3 1" INSULATED CLEAR GLASS IN PRE -FINISHED ALUMINUM STOREFRONT PREFINISHED ALUMINUM INSULATED SPANDRAL PANEL FINISHED ON INTERIOR AND EXTERIOR. MATCH STROEFRONT COLOR. T = TEMPERED GLASS 1 2 WALL TYPE 1 1 1/2" = 1'-0" WALL TYPE 4 1 1/2" = 1'-0" TYP. BOTH SIDES OF WALL. 5/8" GYPSUM BOARD. EXTEND TO CEILING GRID LINE 3 5/8" 25 GA. METAL STUDS AT 16" PROVIDE CHICAGO METALLIC ELIMINATOR TRACK AT CEILING/WALL INTERSECTION. TYP. BOTH SIDES OF WALL. 5/8" TYPE "X" GYPSUM BOARD. ATTACH GYP. BOARD WITH 1 1/4" TYPE "S" DRYWALL SCREWS AT 8" OC. AT EDGES AND 12" OC AT INTERMEDIATE STUDS. STOP GYP BOARD 1/2" FROM TOP OF WALL AND PROVIDE CONT. FIRE SAFE JOINTS. FILL WALL SOLID WITH SAFB INSULATION STUD PDEPTH I(N6S jLATION TO MATCH EXISTING 6" METAL STUDS AT 16" OC, INSTALLED BY BUILDING OWNER. VERIFY LOCATION OF WALL MATCHES PLAN, AND NOTIFY ARCHITECT OF ANY DISCRPANCI S. NOTE: WALL CONSTRUCTED TO ACHEIVE 1 HOUR FIRE RATING, PER UL LISTING. PROVIDE NECESSARY FIRE STOPPING MATERIAL AT ANY PENETRATIONS. (UL ASSEMBLY U465) GYP BOARD ON OPPOSITE SIDE OF DEMISING WAL S TO BE PROVIDED AND INSTALLED BY ADJACENT TENANT TIME OF THEIR BUILD OUT. BUILDING OWNER SHALLV RIFY THAT TOTAL WALL ASSEMBLY IS CONSTRUCTED AS SHOWN HEREIN. NOTE: COORDINATE WITH OWNER ON COLUMN DETAIL WHICH IS TO MATCH COLUMNS IN OWNER'S MURAL. INTERIOR ELEVATION 1/2" = 1'-0" EANDAD C0�8T GYP EBD., PD OF AIN ED L X 1 3/4" THK. TRIM WITH RAD. EDGE T. AND B. M SET AT ANGLE TO FLOOR PLAN TE 6 FOR INFORMATION. IN CONSTRUCTED OF METAL AND 5/8" GYP BD., P-2 L X 1 3/4" THK. TRIM WITH RAD. EDGE T. AND B. TRIM SET AT ANGLE 1/2" TRIM STOCK TRIM WITH G. EDGE QUARTER ROUND B-1 J Z ~ o F- >� �W m m V Qii7u�U�cc - Z Ln W U f- uu� Z2a�oG u w J ~ � c7�zQo3:Lu-- z Lu N g w w�dLw02 0¢?c�W� o (-- �zu���a Lo w 2 V z C14 N \ \ Q °=00�L)I =0�"'~Q� ,,�/ LL Z ►-wWW3zu o?CLm��� QZa O0<0 cC UZ L)0 J 0 Z LL 2 V d�Uw0~m dwwwLuzL • V) Lu Z OU u . 1uuF- z 0 z< uu0 I—oWX V O 00 N cV aCZo� W Q � z Q . M 0 z ^ U w Ln J — U- w M m z W 0 U Z m QwwZ 0 0 u u U - vi Z J W ~ F- j m m w Ln o " w J � a � � z Lu N g o p 0 Lo w Ij D CN C14 N \ \ !2 co 00 a W GEL04002 A1.2 INTERIOR ELEVATION 1/2" = 1'-0" FRP-1 TO UNDERSIDE OF CABINETS, TYP. PAINT ABOVE FRP-1 6'-6" AFF PAINT ABOVE CEILING C-1 AT 12'-0" AF UPPER CABINETS PROVIDED BY OWNER, INSTALLED BY GC. REFER TO 6/A1.2 FOR MORE INFO. FRP-1 TO UNDERSIDE OF CABINETS, TYP. PAINT ABOVE 1 1/2" THK. PLASTIC LAMINATE COUNTER, BY OWNER PLASTIC LAMINATE BACK SPLASH, BY OWNER SINK, REFER TO ENGINEERING DRAWINGS CABINET DOORS, MATCH UPPER CABINET FINISH B-2 —� INTERIOR ELEVATION 1/2" = 1'-0" 12'-10" 1'-0" COORDINATE WITH OWNER ON FINAL LAYOUT, SCOPE AND EQUIPMENT REQUIREMENTS. INTERIOR ELEVATION 1/2* = 1'-0" INTERIOR ELEVATION 1/2" = V -0 - COORDINATE WITH OWNER ON FINAL LAYOUT, SCOPE AND EQUIPMENT REQUIREMENTS. FRP -1 6'-6" AFF PAINT ABOVE NOTE: ELEVATION SHOWN FOR REFERENCE ONLY COORDINATE WITH OWNER ON FINAL LAYOUT, SCOPE AND EQUIPMENT REQUIREMENTS. INTERIOR ELEVATION 1/2" = 1'-0" z O t0 tblian Dessert PRE -FINISHED ALUMINUM STOREFRONT SYSTEM COLOR TBD 3-6 X 8-0 PRE -FINISHED ALUMINUM DOOR T = TEMPERED GLASS NOTE: SUBMIT SHOP DRAWINGS AND FINISH SAMPLES OF FRAME, ALUMINUM PANEL AND GLAZING FOR REVIEW. REFER TO 6/A1.2 FOR ELEVATION OF STOREFRONT. FRP-1 6'-6" AFF PAINT ABOVE B-2 � T 1 "X 1 " MUNTINS APPLIED TO EXTERIOR SIDE OF 1" INSUL. CLEAR TEMPERED GLASS. PRE -FINISHED COLOR TBD FIRE RESISTIVE AWNING MATERIAL OVER ALUMINUM FRAME. AWNING COLOR TBD, AS MANU. BY SUNBRELLA, OR EQUAL T Espresso ALUMINUM SPANRAL PANELS GLAZED INTO STOREFRONT, COLOR TO MATCH FRAME 1" INSULATED CLEAR GLASS, TYPICAL T EXISTING BUILDING ELEVATION - NEW STOREFRONT 1/4" = 1'-0" P-1 2'-6" 1'-3" z P-4 0 �F nW o P-2 U P-2 OPEN RANGE LU n P-2 N m pp 0E-�o�c� 12'-10" w CcWD=CL �Z�W� P-1 H 2 ucc ai oWo00u� U 4'-1" 4'-1" Q 5' J) F- Z a W Z U cn Z in u ZFQ-coc0°e�$ QZ0- CLD ZU<0--= U �N�Zeou - Q�u ,OF-� w Inc Lu z REFER TO ENGINEERING DWGS LU LA ZWpOZu U • 3: 0 �uu?a�00 WC -1 (MURAL) PROVIDED BY OWNER = W o U i Lu LL O oo v rq 00 GIC Z O 103 O P-2 ^ P-2 Z Q . M FAUX PAINTING U INTERIOR ELEVATION 1/2" = 1'-0" 12'-10" 1'-0" COORDINATE WITH OWNER ON FINAL LAYOUT, SCOPE AND EQUIPMENT REQUIREMENTS. INTERIOR ELEVATION 1/2* = 1'-0" INTERIOR ELEVATION 1/2" = V -0 - COORDINATE WITH OWNER ON FINAL LAYOUT, SCOPE AND EQUIPMENT REQUIREMENTS. FRP -1 6'-6" AFF PAINT ABOVE NOTE: ELEVATION SHOWN FOR REFERENCE ONLY COORDINATE WITH OWNER ON FINAL LAYOUT, SCOPE AND EQUIPMENT REQUIREMENTS. INTERIOR ELEVATION 1/2" = 1'-0" z O t0 tblian Dessert PRE -FINISHED ALUMINUM STOREFRONT SYSTEM COLOR TBD 3-6 X 8-0 PRE -FINISHED ALUMINUM DOOR T = TEMPERED GLASS NOTE: SUBMIT SHOP DRAWINGS AND FINISH SAMPLES OF FRAME, ALUMINUM PANEL AND GLAZING FOR REVIEW. REFER TO 6/A1.2 FOR ELEVATION OF STOREFRONT. FRP-1 6'-6" AFF PAINT ABOVE B-2 � T 1 "X 1 " MUNTINS APPLIED TO EXTERIOR SIDE OF 1" INSUL. CLEAR TEMPERED GLASS. PRE -FINISHED COLOR TBD FIRE RESISTIVE AWNING MATERIAL OVER ALUMINUM FRAME. AWNING COLOR TBD, AS MANU. BY SUNBRELLA, OR EQUAL T Espresso ALUMINUM SPANRAL PANELS GLAZED INTO STOREFRONT, COLOR TO MATCH FRAME 1" INSULATED CLEAR GLASS, TYPICAL T EXISTING BUILDING ELEVATION - NEW STOREFRONT 1/4" = 1'-0" P-1 2'-6" 1'-3" z ILO M MICRO I LOCKING 0 �F nW o W Q U XJ F -Lu Q[auOw OPEN RANGE LU n CD 0 to CN \ N m pp 2'-0" NOTE: ELEVATION SHOWN FOR REFERENCE ONLY COORDINATE WITH OWNER ON FINAL LAYOUT, SCOPE AND EQUIPMENT REQUIREMENTS. INTERIOR ELEVATION 1/2" = 1'-0" ' J Q 12'-4" +/- TYP. ROUGH OPENING app.uccino T J3__ V¢- z H g o �F nW o W Q U XJ F -Lu Q[auOw < W :D LU n CD 0 to CN \ N m pp 0E-�o�c� w CcWD=CL �Z�W� H 2 ucc ai oWo00u� U a Q 5' J) F- Z a W Z U Z in u ZFQ-coc0°e�$ QZ0- CLD ZU<0--= U �N�Zeou - Q�u ,OF-� w Inc Lu z LU LA ZWpOZu U • 3: 0 �uu?a�00 W o U Lu LL O oo v rq 00 GIC Z O O% W Q00 Z Q . M O U Lu Ln — O w M m Z Q m W LuN Z ~ O co u Q W 0 O o u u u; Z J3__ V¢- W H g j C=m L o W Q � z 0 0 Lu Lo N CN 1-1 CD 0 to CN \ N m pp v �C EAR SEALANT, ICAL O I DEMISING WALL L CATION I W v�W � o c;O k z� d rn b.. u -L NOTE: ELEVATION SHOWN FOR REFERENCE ONLY COORDINATE WITH OWNER ON FINAL LAYOUT, SCOPE AND EQUIPMENT REQUIREMENTS. 2 INTERIOR ELEVATION A1.3 MATERIALS SCHEDULE MARK MATERIAL MANUFACTURER COLOR PATTERN/TEXTURE NUMBER REMARKS W qdt¢�� u CT -1 CERAMIC TILE TBD N F- Q�m u W CT -2 CERAMIC TILE TBD Q H Lu w Lu Lij a( �oCw�x P-1 PAINT SHERWIN WILLIAMS CHAMPAGNE SATIN FINISH SW6644 GENERAL WALL COLOR AND UNDERFACE OF ARCHES U P-2 PAINT PORTER DUSTY APRICOT SATIN FINISH 6808-2 FACE OF COLUMNS, BULKHEAD AND ARCHES P-3 PAINT CUSTOM MATCH BASE B-1 SEMI GLOSS FINISH <F-cC Qno Z(LFn. P-4 PAINT PORTER POWDER BLUE SATIN FINISH 6488-1 GYP BOARD CEILING U P-5 PAINT TBD QzuWO~� d w: W Z FRP-1 FIBERGLASS REINF. PANELS KEMLITE IVORY NUBBY FINISH -- SEE SCHEDULE AND ELEVATIONS FOR HEIGHTS. tx-Ou?< uu0 WC -1 WALL COVERING BY OWNER -- -- -- PROVIDED BY OWNER, INSTALLED BY GC W B-1 VINYL BASE FLEXCO FJORD SCULPTURES SC -043 (WOOD PROFILE) PROVIDED BY OWNER, INSTALLED BY GC Lu B-2 VINYL BASE ROPPE EGGSHELL COVE BASE P179 4 1/2" HIGH, 1/8" 00 PL -1 PLASTIC LAMINATE FORMICA QUILTED ALUMINUM QUILTED FINISH 5163-15 0C z PL -2 PLASTIC LAMINATE PIONITE JEWEL MAHOGANY MATTE FINISH WY351-H PL -3 PLASTIC LAMINATE WILSONART PEARL SILVER LS MATTE FINISH D487-07 PL -4 PLASTIC LAMINATE WILSONART NATURAL ALUMINUM POLISHED 6251-419 U CAB -1 PRE-MANU. CABINETS BY OWNER -- -- -- PROVIDED BY OWNER, INSTALLED BY GC — cr) C-1 ACOUSTICAL CEILING TILE USG WHITE CLEAN ROOM 100 56091 PROVIDE 15/16" DONN DX GRID, WHITE W ROOM FINISH SCHEDULE Z Y F- 0 MARK ROOM NAME FLOORING BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CABINETS/ COUNTERTOPS CEILING MAT./ HEIGHT REMARKS 100 DINING AREA CT -1 B-1 P-2 P-1 /P-2 P-2 P -1/P-2 PL -2 GYP BD. P-5 14-9 101 DINING AREA CT -2 B -1/B-2 P WC P' 2 P-1 P-2 P-1 /P-2 GYP 1BD.9P-4 102 SERVING AREA STAINED CONCRETE B-2 FRP-l/ P-1 FRP-l/ P-1 FRP-l/ P-1 FRP-l/ P-1 CAB -1 */* PL-1,PL-3 C-1 / 12-0 FLOOR JOINTS, CRACKS, AND IMPERFECTIONS TO BE CAU *COUNTERS/ CABINETS AND SHELVES IN THIS ROOM PRO KED IDED BY OWNER 103 PREP AREA STAINED CONCRETE B-2 FRP-1 6'-6"/FRP-1 P-1 6'-6" + 6'-6"/ P-1 6'-6" + FRP-1 6'-6-/ P-1 6'-6" + P-1 CAB -1 */ PL -3 ' C-1/ 11-0 FLOOR JOINTS, CRACKS, AND IMPERFECTIONS TO BE CAU COUNTERS / CABINETS AND SHELVES IN THIS ROOM PROVIDED KED BY OWNER 104 TOILET ROOM STAINED CONCRETE B-2 FRP-1 4'-O-/FRP-1 P-2 4'-0" + 4'-O"/FRP-1 P-2 4'-0" +[P-2 4'-O"/FRP-1 4'-0" + 4'-0"/ P-2 4'-0" + C-1/ 11-0 105 STORAGE ROOM STAINED CONCRETE B-2 P-1 P-1 I P-1 1 P-1 C-1/ 11-0 FLOOR PLAN 1/4" = 1'-0" w r 0 iQ >> H � U W qdt¢�� u V W N F- Q�m u W F- 61 Z�wH Q H Lu w Lu Lij a( �oCw�x I<— �Z�oWC~wQ uac►-� O U aWOo0u� N 1-11 Q „x oF- <m °W3zu 00 z w <F-cC Qno Z(LFn. �0JF-Z�2 U ce �QN�Zou QzuWO~� d w: W Z • W !'Zwoo u v�Zw�OZrJ U � tx-Ou?< uu0 W U Lu �-- 0 00 V) fV 00 0C z O 0� W Qcc)z — °% M 0 z U U 1 i MJ Ln ..J — — cr) O w M } Z a m c7 W Z Y F- 0 m U w Z 0 o U u V) z J W iQ H � W M V N � W � Q H Lu cl C) O W tl ij N 1-11 --%. N 00 00 GEL04002 A1.4 ELECTRICAL EQUIPMENT AND MATERIAL DISCONNECT SWITCH #1: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 30 AMP, 480 VOLT, FUSIBLE, WITH 20 AMP FUSES AND NEMA 3R ENCLOSURE. SQUARE D #H361 RB. DISCONNECT SWITCHES #2: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 30 AMP,480 VOLT, FUSIBLE, WITH 5 AMP FUSES AND NEMA 1 ENCLOSURE. SQUARE D #H361 RB. PANEL AH®: SQUARE D TYPE NFCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 277/480 VOLT, 3 PH., 4 WIRE. AIC RATING AS REQUIRED - VERIFY IN FIELD WITH UTILITY. TRANSFORMER: 75 KVA, DRY TYPE. SQUARE D #75T3H. PRIMARY: 480 VOLT, 3 PH., 3 WIRE. SECONDARY: 120/208 VOLT, 3 PH., 4 WIRE. PANEL AA®: SQUARE D TYPE NQODCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3 PH., 4 WIRE. AIC RATING AS REQUIRED - VERIFY IN FIELD WITH UTILITY. TIME CLOCK: DPDT, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH RESERVE POWER FEATURE. TORK #W220L. DEVICES AND COVERPLATES LISTED BELOW SHALL BE COLOR COORDINATED WITH THE ARCHITECT AND/OR INTERIOR DESIGNER PRIOR TO PURCHASE DUPLEX RECEPTACLES: HUBBELL #5362. GROUND FAULT RECEPTACLE: HUBBELL #GF -5362. ISOLATED GROUND RECEPTACLES: HUBBELL #IG -5362. QUAD RECEPTACLES: TWO (2) HUBBELL #5362 DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. IG QUAD RECEPTACLES: TWO (2) HUBBELL #IG -5362 DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. FLOOR RECEPTACLES: HUBBELL #HBL-5362 IN A #B-2524 BOX WITH #S-3725 FLUSH COVER. WEATHERPROOF RECEPTACLES: HUBBELL #GF -5362 WITH "A8" ALUMINUM COVER PLATE. TELEPHONE/MODEM/HYPERCOM OUTLETS: HUBBELL TYPE RJ11C WITH WHITE COVER PLATE. DATA OUTLETS: HUBBELL TYPE RJ45 WITH COVER PLATE. SINGLE POLE SWITCHES: HUBBELL #HBL-1221. DIMMER SWITCHES: LUTRON #N-2000, 20 AMP, 120 VOLT. COVERPLATES: HUBBELL, COLOR AS REQUIRED BY ARCHITECT AND/OR INTERIOR DESIGNER. ELECTRICAL WORK NOTES 1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS AND CLAY TERRACE MEP CRITERIA DRAWINGS MEP1, MEP2 AND MEP3 - CONTACT LANDLORD FOR COPIES OF DRAWINGS. 2. THE SPACE IS NEW AND HAS NOT PREVIOUSLY BEEN OCCUPIED. REMOVE EXISTING LIGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, WIRE, ETC., NOT REQUIRED FOR THE NEW INSTALLATION. UNUSED FIXTURES SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE. 3. FURNISH AND INSTALL ALL NEW LIGHTING FIXTURES AS PART OF THE ELECTRICAL CONTRACT. 4. FURNISH AND INSTALL NEW 277/480 VOLT, 3 PH., 4 WIRE, 150 AMP ELECTRICAL SERVICE TO SPACE (CRITERIA INDICATES THAT LANDLORD HAS OR WILL PROVIDE AN EMPTY CONDUIT WITH PULL STRING TO THE SPACE-VERFIY EXACT SIZE WITH LANDLORD (2" MIN)) - UTILIZE THIS CONDUIT AND FURNISH AND INSTALL THE SERVICE WIRING AS SHOWN AND CALLED FOR. LEAVE 15' WIRE COIL IN LANDLORD=S WIREWAY ABOVE LANDLORD=S DISTRIBUTION EQUIPMENT. 5. LANDLORD HAS OR WILL PROVIDE A NEW 150 AMP CIRCUIT BREAKER OR A 200 AMP FUSIBLE SWITCH WITH 150 AMP FUSES IN LANDLORD=S ELECTRICAL EQUIPMENT (COST FOR THIS ITEM(S) SHALL BE BY THE TENANT - COORDINATE WITH LANDLORD). OVERCURRENT PROTECTION SHALL BE 150 AMP. FIELD VERIFY WITH THE LANDLORD THE EXACT EQUIPMENT TYPES, LOCATIONS, ORIENTATIONS, SIZES, ETC. COORDINATE WITH THE LANDLORD ANY REQUIRED WORK AT THE DISTRIBUTION CENTER TO ENSURE COMPATIBILITY AND ACCEPTABILITY WITH LANDLORD=S EQUIPMENT. IF ANY ISSUES ARISE WITH REGARD THE INSTALLATION OF SERVICE AND EQUIPMENT, CONTACT ARCHITECT AND/OR ENGINEER PRIOR TO BID FOR DISPOSITION. LANDLORD=S ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO LANDLORD=S SERVICE EQUIPMENT AS REQUIRED AT TENANT=S EXPENSE. CONTACT THE LANDLORD TO COORDINATE THIS PORTION OF THE WORK. NO EXTRAS WILL BE ALLOWED FOR WORK NOT INCLUDED IN BASE BID. 6. FURNISH AND INSTALL THREE (2) NEW ELECTRICAL PANELS AH®, AA®, AND A 75 KVA TRANSFORMER AS SHOWN AND CALLED FOR. 7. CONNECT ALL CIRCUITS TO PANELS AS REQUIRED. CIRCUITS SHALL BE ARRANGED ON THE PANELS IN STRICT ACCORDANCE WITH THE NUMBERS SHOWN ON THE DRAWINGS. NO VARIATION OR DEVIATION FROM THE DRAWING WILL BE ACCEPTED. ANY CHANGE IN CIRCUITING DUE TO ACTUAL FIELD CONDITIONS MUST BE APPROVED BY THE ENGINEER PRIOR TO AFFECTING THE CHANGE. ANY WORK PERFORMED ASIDE FROM THAT SHOWN, INDICATED OR IMPLIED MUST BE APPROVED BY THE PROJECT MANAGER AND/OR ENGINEER BEFORE STARTING. ALL. UNUSED CIRCUITS SHALL BE UTILIZED AS SPARES. 8. FURNISH AND INSTALL NEW TYPEWRITTEN PANEL DIRECTORIES IN t.'_L NEW PANELS. 9. PROVIDE TEMPORARY WIRING AS REQUIRED WHILE SERVICE AND EQUIMENT ARE BEING INSTALLED TO ALLOW FOR LIGHTING AND POWER FOR CONSTRUCTION PURPOSES. WHEN INSTALLING SERVICE AND EQUIPMENT, KEEP SHUTDOWN TIME TO A MINIMUM. 10. TELEPHONE SERVICE TO THE SPACE WILL BE PROVIDED BY THE LANDLORD. CONTACT THE TELEPHONE COMPANY TO ARRANGE FOR ANY CHANGE IN TELEPHONE SERVICE. FURNISH AND INSTALL ALL ADDITIONAL CONDUIT REQUIRED IN THE SPACE. 11. FURNISH AND INSTALL NEW TELEPHONE TERMINAL BOARD FOR THE NEW INSTALLATION. NEW TELEPHONE TERMINAL BOARD SHALL BE 12" X 12" PLYWOOD, 3/4" THICK, MOUNTED ON WALL, READY TO RECEIVE TELEPHONE EQUIPMENT. 12. TEMPERATURE CONTROL WORK, WILL BE A PART OF THE MECHANICAL CONTRACT. ALL CONTROL WIRING SHALL BE IN CONDUIT. 13. SEE ARCHITECTURAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE, EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. MECHANICAL EQUIPMENT AND MATERIAL - A.C. UNITS: SEE A.C. UNIT SCHEDULE. CEILING DIFFUSERS: SEE AIR DEVICE SCHEDULE. RETURN AIR REGISTERS: SEE AIR DEVICE SCHEDULE. TOILET EXHAUST FAN: SEE FAN SCHEDULE. WATER CLOSET: CONTACT INTERIOR DESIGNER FOR SPECIFICATION. MOP SINK: STERN-WILLIAMS #MTB -2424, FLOOR MOUNTED, TERRAZO, 24" X 24", COMPLETE WITH INTEGRAL 3" BRASS DRAIN, STAINLESS STEEL DOME WITH STRAINER AND SCREWS AND #8344.112 AMERICAN STANDARD FAUCET WITH TOP BRACE, STOPS AND VACUUM BREAKER. LAVATORY: CONTACT INTERIOR DESIGNER FOR SPECIFICATION. 3 COMPARTMENT SINK: CONTACT INTERIOR DESIGNER FOR SPECIFICATION. COUNTER HAND SINKS: CONTACT INTERIOR DESIGNER FOR SPECIFICATION. STATE #LDK-40-10MS, ELECTRIC, 16 GPH ® 100o RISE, 406 GALLON STORAGE, 1,650 WATTS, 120 VOLT, 1 PH, 60 HZ. FLOOR DRAINS: ZURN #ZN-456-P, CAST IRON BODY, DEEP SEAL TRAP, FLOOR LEVEL CLEANOUT AND NICKEL BRONZE TYPE AB® STRAINER COMPLETE WITH 1/2" TRAP PRIMER CONNECTION. CLEANOUTS: ZURN #ZN-1400-3, WITH SQUARE NICKEL BRONZE COVER. WALL CLEANOUTS: ZORN #ZB-1443-3, WITH SQUARE POLISHED BRONZE ACCESS COVER AND FRAME. TRAP PRIMERS: ZURN #Z-1022. WATER METER: AALIANT MODEL #N100BR N, WITH U.S. GALLON READING REGISTER. GREASE TRAP: 20 POUND CAPACITY WITH 10 GPM. DUCTWORK: RIGID: GALVANIZED SHEET METAL, IN ACCORDANCE WITH ASHRAE AND SMACNA REQUIREMENTS FOR LOW PRESSURE DUCTWORK (1" WC). FLEXIBLE (IF USED -BY GC): WIREMOLD TYPE WCK OR EQUAL FLEXIBLE CLASS 1 AIR DUCT, METALIZED POLYESTER FILM LAMINATED ON STEEL WIRE REINFORCING, WITH 1.5" THICK, 3/4 LB DENSITY FIBERGLASS INSULATION AND FIRE RETARDENT REINFORCED VAPOR BARRIER (HI -VINYL) AND SHALL MEET NFPA 90A AND UL STANDARD 181. PIPING MATERIALS: DOMESTIC COLD WATER: TYPE L HARD TEMPER COPPER WITH WROUGHT SWEAT FITTINGS. WASTE AND VENT: STANDARD WEIGHT CAST IRON WITH NO -HUB FITTINGS. REFRIGERANT PIPING: TYPE K HARD TEMPER COPPER WITH WROUGHT SWEAT FITTINGS AND 95-5 SOLDER. CONDENSATE PIPING: TYPE L HARD TEMPER COPPER WITH WROUGHT SWEAT FITTINGS. DUCTWORK INSULATION (SUPPLY AND OUTSIDE): WRAP IN ACCORDANCE WITH THE FOLLOWING: WRAP: 1.5" THICK, 3/4 LB. DENSITY FIBERGLASS INSULATION WITH VAPOR BARRIER JACKET PIPING INSULATION: DOMESTING COLD AND HOT WATER: 1.5" THICK, 3/4 LB. DENSITY FIBERGLASS WITH VAPOR BARRIER JACKET. ALL LIQUID REFRIGERANT PIPING AND SUCTION REFRIGERANT PIPING: 1/2" THICK FLEXIBLE FOAMED PLASTIC. ARMSTRONG "ARMAFLEX-2". MECHANICAL WORK NOTES 1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS. REFER IN PARTICULAR TO LANDLORD'S TENANT HANDBOOK AND CLAY TERRACE MEP CRITERIA DRAWINGS MEP1, MEP2 AND MEP3 - CONTACT LANDLORD FOR COPIES OF DRAWINGS. 2. THE LANDLORD WILL PROVIDE WATER, SEWER AND VENT PIPING STUBS AT OR NEAR THE SPACE. EXTEND AND CONNECT WATER, SEWER AND VENT PIPING AS SHOWN. MORE THAN ONE UTILITY STUB MAY EXIST WITHIN SPACE - VERIFY LOCATION OF CLOSEST STUB AND UTILIZE IT AS REQUIRED. CAP ALL STUBS NOT REQUIRED FOR THIS INSTALLATION. FURNISH AND INSTALL A METAL PLUGGED TEE IN THE VENT PIPING TO PERMIT CONNECTION TO THE VENT STACK - VERIFY EXACT LOCATION AND REQIUIREMENTS IN FIELD. 3. CONTACT LOCAL UTILITY COMPANY TO ARRANGE FOR WATER SERVICE AND METER INSTALLATION. FURNISH AND INSTALL WATER METER AS SHOWN AND CALLED FOR. 4. ONE (1) NEW TOILET ROOM WILL BE CONSTRUCTED. FURNISH AND INSTALL ab FURNIS????NEW PLUMBING FIXTURES, INCLUDING LAVATORY, WATER CLOSET, MOP SINK, WATER HEATER, ETC., IN THE LOCATIONS SHOWN - IN ADDITION, FURNISH AND INSTALL ALL HAND SINKS AND OTHER PLUMBING ITEMS THROUGHOUT THE SPACE AS SHOWN???? AND CALLED FOR. CONNECT ALL WATER, WASTE AND VENT TO LANDLORD PROVIDED STUBS IN THE SPACE AND EXTEND TO ALL NEW FIXTURE LOCATIONS. VERIFY EXACT LOCATION OF LANDLORD PROVIDED STUBS AND LENGTH OF PIPING REQUIRED IN FIELD PRIOR TO BID. BASE BID SHALL INCLUDE ALL PIPING NECESSARY FOR A COMPLETE INSTALLATION AND CONNECTION TO ALL PROVIDED STUBS. 5. NEW WATER HEATER SHALL BE MOUNTED ON THE DECK ABOVE THE MOP SINKIN THE LOCATION SHOWN AND CALLED FOR. WATER HEATER SHALL BE SECURED TO THE FLOOR AND OR WALL AS REQUIRED. NEW WATER HEATER SHALL BE MOUNTED IN A GALVANIZED DRAIN PAN, 6" DEEP. PRESSURE/TEMPERATURE RELIEF VALVE AND THE DRAIN PAN SHALL BE PIPED TO THE MOP SINK WITH APPROVED AIR GAP AS REQUIRED. 6. CUT AND PATCH THE FLOOR AS REQUIRED TO INSTALL NEW WASTE PIPING. 7. THE ELECTRICAL CONTRACTOR WILL PROVIDE COMBINATION FAN/LIGHT FIXTURE IN LOCATION SHOWN. EXTEND TOILET EXHAUST DUCTWORK TO LANDLORD PROVIDED TOILET EXHAUST DUCTWORK. 8. FURNISH AND INSTALL NEW A.C. SPLIT SYSTEMS AS SHOWN AND CALLED FOR, INCLUDING CONDENSING UNIT AND AIR HANDLING UNITS AS REQUIRED FOR COMPLETE SYSTEMS. 9. SET NEW CONDENSING UNIT ON ROOF IN LOCATION SHOWN (VERIFY EXACT MOUNTING LOCATIONS IN FIELD WITH LANDLORD). LANDLORD MAY HAVE IDENTIFIED AREAS ON THE ROOF FOR MOUNTING OF CONDENSING UNITS - VERIFY IN FIELD WITH LANDLORD PRIOR TO MOUNTING ANY EQUIPMENT, ROUTING ANY PIPING, ETC. 10. AIR HANDLING UNIT SHALL BE INSTALLED IN THE LOCATION SHOWN AND CALLED FOR. EXACT LOCATIONS SHALL BE ADJUSTED TO ACCOMMODATE INSTALLATION ABOVE THE CEILING AS REQUIRED. 11. THE NEW AIR HANDLING UNIT SHALL BE SUSPENDED AND SUPPORTED FROM ABOVE AS SHOWN AND CALLED FOR. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NEW SUPPORTS. IF REQUIRED, MECHANICAL CONTRACTOR SHALL ENLIST THE SERVICES OF A REGISTERED PROFESSIONAL STRUCTURAL ENGINEER TO REVIEW AND CERTIFY THE PROPOSED SUPPORT ARIOR TO AFFECTING ANY WORK OR CONSTRUCTING ANY SUPPORT. ANY DRAWINGS AND/OR SPECIFICATIONS REQUIRED BY THE BUILDING DEPARTMENT AND/OR LANDLORD FOR THE PROPOSED SUPPORT SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. ANY AND ALL DESIGN, CERTIFICATION AND SUBMITTALS REQUIRED FOR THIS WORK SHALL BE BY THE CONTRACTOR AT THE CONTRACTOR=S EXPENSE. 12. AIR HANDLING UNIT SHALL BE MOUNTED IN A GALVANIZED DRAIN PAN, 2" DEEP (SECONDARY TO THE DRAIN PAN INSIDE THE UNIT). EVAPORATOR COILS AND DRAIN PANS SHALL BE PIPED TO THE MOP SINK WITH APPROVED AIR GAPS. ENSURE PROPER INSTALLATION OF ALL CONDENSATE DRAIN PIPING (MAINTAIN PROPER SLOPE, ETC.) AND FURNISH AND INSTALL A CONDENSATE DRAIN PUMP IF REQUIRED TO PROPERLY RID THE SPACE OF CONDENSATE AND MAINTAIN PROPER DRAINAGE. 13. ANY AND ALL SYSTEMS REQUIRING ANY WORK TO THE ROOF SHALL BE COORDINATED AND PERFORMED BY THE LANDLORD=S DESIGNATED ROOFING CONTRACTOR AS REQUIRED. CONTACT THE LANDLORD=S ROOFING CONTRACTOR TO COORDINATE ANY ROOF WORK AS REQUIRED. 14. FURNISH AND INSTALL CLEAN FILTERS IN THE AIR HANDLING UNITS AFTER ALL WORK IS COMPLETED AND THE PROJECT IS TURNED OVER TO THE OWNER. 15. FURNISH AND INSTALL ALL NEW EQUIPMENT, DUCTWORK, PIPING, DIFFUSERS, REGISTERS, GRILLES, ETC. AS SHOWN AND CALLED FOR AND REQUIRED. 16. SUPPLY AND OUTSIDE AIR DUCTWORK SHALL BE WRAPPED WITH THE INSULATION SPECIFIED. WRAP SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSION. 17. DUCTWORK, PIPING, ETC., SHALL BE SUSPENDED FROM JOISTS. 18. CUTTING AND PATCHING OF ROOF FOR REFRIGERANT PIPING SHALL BE DONE IN STRICT ACCORDANCE WITH THE LANDLORD=S REQUIREMENTS - CONTACT LANDLORD TO DETERMINE AND COORDINATE. 19. TEMPERATURE CONTROLS, INCLUDING WIRING, SHALL BE PART OF THE MECHANICAL CONTRACT. FURNISH AND INSTALL ALL REQUab FURNIS????IRED CONTROL WIRING AND CONDUIT TO THE THERMOSTAT. G.C. WILL BE RESPONSIBLE FOR SEQUENCING UNIT TO ACCOMODATE PROPER CONTROL OF HEATING AND COOLING CYCLES (SEE MINIMUM LEVEL OF OPERATION AS SHOWN IN TEMPERATURE CONTROL WORK NOTES BELOW). FURNISH AND INSTALL A??LED?? SMOKE DETECTOR IN THE RETURN AIR DUCT AT THE A.C. UNIT THAT WILL SHUT THE UNITS DOWN WHEN SMOKE IS SENSED. 20. FIBERGLASS DUCTWORK IS NOT PERMITTED. 21. FLEXIBLE DUCTWORK MAY BE USED FOR DIFFUSER CONNECTIONS ONLY AND SHALL BE LIMITED IN LENGTH TO 5'-0". 22. ALL DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA STANDARDS AND RECOMMENDATIONS. 23. SEE ARCHITECTURAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE, EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. ELECTRICAL WORK NOTES - GENERAL 1. ELECTRICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 2. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 3. ELECTRICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 4. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. AT NO TIME SHALL ANY WORK BE UNDERTAKEN WHICH SHALL INTERFERE WITH THE NORMAL OPERATION OF BUSINESS. ANY SHUTDOWN MUST OCCUR AFTER REGULAR BUSINESS HOURS AND MUST BE CLEARED WITH THE MANAGEMENT WITH PROPER PRIOR NOTICE GIVEN TO THE OWNER'S REPRESENTATIVE. 5. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ERRORS, OMMISSIONS OR DISCREPENCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 6. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 7. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER/ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 8. ALL WIRE SHALL BE COPPER. MINIMUM SIZE #12 AWG. ALL CONDUCTORS #10 AND SMALLER SHALL HAVE TYPE "THHN" INSULATION. CONDUCTORS LARGER THAN #10 SHALL HAVE TYPE "THW" INSULATION. 9. ALL WIRE SHALL BE IN CONDUIT AND SHALL BE CONCEALED FROM VIEW. EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES PARALLEL WITH OR PERPENDICULAR TO COLUMN LINES OR BEAMS AND SHALL BE SEPERATED BY AT LEAST 3" INCHES FROM DOMESTIC WATER LINES WHENEVER ALONG SIDE OR ACROSS SUCH LINES. ROMEX IS NOT PERMITTED. FLEXIBLE CONDUIT OR TYPE MC CABLE MAY BE USED FOR FIXTURE AND EQUIPMENT CONNECTIONS ONLY, AND WHERE SO USED SHALL BE GROUNDED WITH A SEPERATE FULL SIZED GREEN GROUNDING CONDUCTOR. FLEXIBLE CONDUIT CONNECTIONS SHALL BE LIMITED TO 3'-0" IN LENGTH. CONDUIT EXPOSED TO WEATHER SHALL BE RIGID. ALL OTHER CONDUIT SHALL BE EMT. CONDUIT FITTINGS SHALL BE COMPRESSION OR THREADED TYPE, USE OF SET SCREW FITTINGS IS NOT ACCEPTABLE. 10. CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT IN UNFINISHED AREAS MAY BE EXPOSED. 11. HOME RUNS OVER 100' IN LENGTH SHALL BE #10 WIRE. 12. CONTRACTOR SHALL ENSURE THAT ENTIRE INSTALLATION IN ACCORDANCE WITH N.E.C. ARTICLE 110-26 AND THAT ALL REQUIRED OPERATING AND MAINTENANCE CLEARANCES ARE MAINTAINED AND ACCOUNTED FOR. ADJUSTMENTS TO LAYOUT SHOWN TO ACCOMODATE CLEARANCE REQUIREMENTS SHALL BE DISCUSSED WITH ARCHITECT AND/OR ENGINEER SO AS TO MINIMIZE IMPACT ON OTHER SYSTEMS. CONTACT ARCHITECT AND/OR ENGINEER FOR DISPOSITION. 13. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND BRANCH DEVICES AS REQUIRED. 14. SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. 15. PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL ELECTRICAL SERVICE EQUIPMENT INCLUDING DISCONNECT SWITCHES, PANELS, PUSHBUTTONS AND STARTERS. 16. LIGHTING CIRCUITS WHICH ARE SWITCHED AT PANELS SHALL BE FITTED WITH TYPE "SWD" BREAKERS SUITABLE FOR SWITCHING SERVICE. 17. FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORY(IES). IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. 18. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 19. FURNISH AND INSTALL PANEL LOCKS WHERE SHOWN ON THE DRAWINGS. 20. WIRE EMERGENCY BALLAST AND BATTERY LIGHTS ON SAME CIRCUIT IN AREA AND AHEAD OF LOCAL SWITCHING. 21. EXTERIOR SIGNAGE (IF APPLICABLE) WILL BE FURNISHED AND INSTALLED BY SIGN CONTRACTOR. CONNECT TO SIGNS AND PROVIDE POWER AS REQUIRED FOR A COMPLETE INSTALLATION. COORDINATE THIS PORTION OF THE WORK WITH SIGN CONTRACTOR AND/OR OWNER=S REPRESENTATIVE AS REQUIRED. 22. FURNISH AND INSTALL A 1 1/4" CONDUIT FOR INCOMING TELEPHONE SERVICE TO NEW PLYWOOD BACKBOARD TO LOCATION AS DIRECTED BY LOCAL TELEPHONE COMPANY. VERIFY EXACT LOCATION AND REQUIREMENTS WITH TELEPHONE COMPANY AND LANDLORD'S REPRESENTATIVE IN FIELD. 23. FURNISH AND INSTALL ALL LIGHTING FIXTURES FOR THE PROJECT AS SHOWN AND CALLED FOR. INSTALL ALL FIXTURES AS REQUIRED FOR A COMPLETE INSTALLATION. LEAVE PROTECTIVE COVERING/FILM IN PLACE ON FIXTURES UNTIL FINAL CLEAN-UP. INSTALL LIGHTING FIXTURES IN RATED CEILING SO AS TO MAINTAIN INTEGRITY OF RATING. REPLACE ANY LAMPS THAT HAVE EXPIRED DURING CONSTRUCTION AND MAKE ALL ADJUSTMENTS TO FIXTURES FOR DIRECTION AS REQUIRED PRIOR TO COMPLETION. 24. NOT USED. 25. SWITCHES SHALL BE MOUNTED 4'-6" ABOVE FLOOR. 26. GENERAL PURPOSE RECEPTACLES SHALL BE MOUNTED IN THE BASE OF WALL AS REQUIRED WITH THE ELECTRICAL FEEDS TO EACH RECEPTACLE INSTALLED DOWN IN THE WALL. SEE ARCHITECTURAL DRAWINGS FOR ALL HEIGHTS, DIMENSIONS AND CONFIGURATIONS OF DEVICES NOT INDICATED ON THESE DRAWINGS. REFERENCE SAME DRAWINGS FOR EQUIPMENT NOT IDENTIFIED. 27. VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES AND FLANGES AS REQUIRED. 28. ALL GENERAL PURPOSE RECEPTACLES SHALL BE MOUNTED IN THE BASE OF WALL AS REQUIRED WITH THE ELECTRICAL FEEDS TO EACH RECEPTACLE INSTALLED DOWN IN THE WALL. SEE ARCHITECTURAL DRAWINGS FOR ALL HEIGHTS, DIMENSIONS AND CONFIGURATIONS OF DEVICES NOT INDICATED ON THESE DRAWINGS. REFERENCE SAME DRAWINGS FOR EQUIPMENT NOT IDENTIFIED. ALL WIRING FOR DEVICES SHALL BE IN WALLS AS REQUIRED. USE OF POWER POLES FOR DEVICE WIRING SHALL BE STRICLY COORDINATED WITH THE ARCHITECT/GENERAL CONTRACTOR OR OWNERS REPRESENTATIVE PRIOR TO INSTALLATION. 29. VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES AND FLANGES AS REQUIRED. 30. IG AND GFI RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WIRE, THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPLICED BETWEEN THE DEVICE AND THE PANEL GROUND BUS. 31. MOUNTING HEIGHTS OF OTHER EQUIPMENT ARE NOTED ON ARCHITECTURAL DRAWINGS. 32. SUPPORT ALL FIXTURES ACROSS CEILING TEES OR FROM STRUCTURE ABOVE. IN NO CASE SHALL CEILING TILES OR PLASTER CEILING SUPPORT ANY FIXTURES. 33. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. AND SYMBOLS LIST, FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS. 34. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, AND ONE YEAR GUARANTEE, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 35. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 36. PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND/OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 37. COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. SERV 38. ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. ANY UNAUTHORIZED CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT, ENGINEER AND/OR OWNER'S REPRESENTATIVE. 39. UPON COMPLETION OF WORK, PREPARE LIGHTING AND POWER PROJECT RECORD AS-BUILTS. PRESENT THE COMPLETED DRAWINGS TO THE OWNER. AS -BUILT DRAWINGS SHALL INCLUDE ALL BRANCH CIRCUIT WORK, ANY PANELBOARD INFORMATION, FINAL SWITCHING, ETC. 40. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE PROOFED TO THE SAME OR GREATER RATING THAN THAT OF THE ASSEMBLY. WHERE CONFLICT OCCURS, NOTIFY THE ARCHITECT. 41. ALL FUSES 600 AMPERES OR LESS SHALL BE UL LISTED, CLASS RK1 OR J, LOW -PEAK, DUAL ELEMENT, TIME DELAY, 600 VOLT. ACCEPTABLE MANUFACTURES ARE BUSSMAN, GOULD OR SHAWMUT. 42. VERIFY LOCAL CONDITIONS AT SITE. 43. COMPLY WITH ALL APPLICABLE CODES. 44. SECURE AND PAY FOR ALL REQUIRED PERMITS MECHANICAUPLUMBING WORK NOTES - GENERAL 1. MECHANICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 2. MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 3. MECHANICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 4. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. AT NO TIME SHALL ANY WORK BE UNDERTAKEN WHICH SHALL INTERFERE WITH THE NORMAL OPERATION OF BUSINESS. ANY SHUTDOWN MUST OCCUR AFTER REGULAR BUSINESS HOURS AND MUST BE CLEARED WITH THE MANAGEMENT WITH PROPER PRIOR NOTICE GIVEN TO THE OWNER'S REPRESENTATIVE. 5. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER OF ERRORS, OMMISSIONS OR DISCREPENCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 6. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 7. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER/ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 8. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 9. WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 10. ON ALL PROJECTS WITH AIR CONDITIONING EQUIPMENT WHICH INCLUDES COMPRESSORS (ROOFTOP, SPLIT SYSTEMS, ETC.), INCLUDE AN EXTENDED FOUR (4) YEAR WARRANTY FOR THE COMPRESSOR. 11. VOLUME DAMPERS, SPLITTERS AND DEFLECTORS SHALL BE INSTALLED IN ALL DUCTS TO PERMIT ACCURATE BALANCING OF SYSTEM. THE DAMPERS, SPLITTERS AND DEFLECTORS SHALL BE ADJUSTED TO SATISFY THE HVAC REQUIREMENTS OF THE CONDITIONED SPACE AND LOCKED IN PLACE AS REQUIRED. 12. WORK SHALL ALSO INCLUDE TESTING AND BALANCING OF A.C. SYSTEM BY A CERTIFIED BALANCING CONTRACTOR. CONTRACTOR SHALL SUBMIT COPIES OF TEST AND BALANCE REPORTS SHOWING DETAILED RESULTS OF WORK, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: FLOW READINGS, STATIC PRESSURES, TEMPERATURE READINGS, MOTOR AMPERAGE, BALANCING OF AIR QUANTITIES TO PLAN REQUIREMENTS, ETC. AS REQUIRED. MAKE ALL ADJUSTMENTS AS REQUIRED TO PROVIDE DESIGN AIR FLOW. 13. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 14. WHERE APPLICABLE, FURNISH AND INSTALL VIBRATION ISOLATION AS REQUIRED TO REDUCE, LIMIT OR REMOVE ALL VIBRATIONS FOR ALL MOVING EQUIPMENT. VIBRATION ISOLATION SHALL BE IN ACCORDANCE WITH ASHRAE RECOMMENDATIONS. 15. PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL MECHANICAL EQUIPMENT INCLUDING TENANT=S NAME AND SPACE NUMBER. LETTERS SHALL BE 2" HIGH OR AS REQUIRED BY THE LANDLORD. 16. ALL FABRICATED COMPONENTS (CONTRACTOR OR MANUFACTURER) OF THE OUTSIDE AIR, SUPPLY AIR, RETURN AIR AND EXHAUST AIR SYSTEMS SHALL BE CONSTRUCTED AND INSTALLED AIR TIGHT. THE INSTALLED SYSTEMS SHALL BE PRESSURE TESTED AS REQUIRED. 17. ALL LOW PRESSURE DUCTWORK SHALL BE TESTED AT 2" WATER COLUMN WITH 5% ALLOWABLE LEAKAGE. TEST SECTIONS AS THE INSTALLATION PROCEEDS. ANY LEAKS SHALL BE SEALED BEFORE THE NEXT SECTION IS INSTALLED. TESTED SECTIONS SHALL BE MARKED WITH INDELIBLE MARKER SHOWING DATE AND INITIALS OF CONTRACTOR FOREMAN RESPONSIBLE FOR TESTS. 18. FURNISH TWO (2) COPIES OF AS BUILT DRAWINGS OF THE A.C. SYSTEM TO THE TENANT FOR REVIEW AND APPROVAL, OR SUBMIT A LETTER TO THE TENANT CONFIRMING THAT THE SYSTEM WAS INSTALLED AS PER PLANS AND SPECIFICATIONS. 19. ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 20. SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. 21. FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, PIPING VALVES, CLEANOUTS, ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING CLEARANCE AND ACCESS. 22. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EACH FIXTURE. FURNISH AND INSTALL AN ACCESSIBLE SERVICE VALVE ON ALL BRANCH PIPING. 23. FURNISH AND INSTALL CHAMBER SHOCK ABSORBERS AS SHOWN TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. 24. FURNISH AND INSTALL PRESSURE REGULATOR ON THE INCOMING WATER SERVICE AS CALLED FOR AND REQUIRED. 25. FURNISH AND INSTALL ALL PIPE HANGERS, CARRIERS, SADDLES, AND SUPPPOTS TO PROPERLY SUPPORT AND PROTECT ALL PIPING IN THE SPACE AS REQUIRED. HANGERS FOR HORIZONTAL PIPING WHERE PIPING IS TO BE INSULATED BE LARGE ENOUGH TO PASS INSULATION AND SHALL BE ELCEN FIG. 12 CLEVIS TYPE, WITH MEANS FOR VERTICAL ADJUSTMENT. INSTALL HANGERS AS FOLLOWS: PIPE SIZE HANGER ROD SIZE MAXIMUM SPACING 1/2- TO 1 " 3/8" 8'-0" O.C. 1-1/4" TO 2" 3/8" 10'-0" O.C. 2-1/2- AND ABOVE 1/21) 10'-0" O.C. 26. VERIFY LOCATION, DEPTH AND SIZE OF EXISTING SANITARY SEWER AT SITE. CONNECT AS REQUIRED. SEWER SHALL BE INSTALLED WITH 1/4" PITCH PER FOOT AND OUTSIDE SEWER SHALL BE INSTALLED WITH MINIMUM OF 3'-0" COVER. 27. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 28. ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 29. FURNISH AND INSTALL TRAP PRIMERS ON ALL FLOOR DRAINS. 30. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 31. PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND/OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 32. COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. 33. ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. ANY UNAUTHORIZED CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE. 34. NOT USED. 35. VERIFY LOCAL CONDITIONS AT SITE. 36. COMPLY WITH ALL APPLICABLE CODES. 37. SECURE AND PAY FOR ALL REQUIRED PERMITS. 38. SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. 39. ALL INSULATION MATERIALS, INCLUDING, BUT NOT LIMITED TOO DUCT INSULATION AND PIPING INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. 41. DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMILAR METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON EACH END THREADED TO MATCH THE ADJACENT PIPING. METAL COMPONENTS SHALL BE SEPARATED BY A NYLON INSULATOR TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE: ASTM A-234 MECHANICAL WORK NOTES - AIR FILTERS 1. ON THE DAY OF STORE CONSTRUCTION COMPLETION/TURNOVER, THE AIR CONDITIONING EQUIPMENT FILTERS, IF ANY, (WHETHER NEW CONSTRUCTION OR EXISTING) SHALL BE REPLACED WITH NEW FILTERS. C\2 .-4 co o I 1 C\2 co co U O C\2 �to ccC\2 Z co r- aA �� �Zwwo CID�: a) Z oo 0 U O C\2 w 0 co co z d" Z�too= C\2A t�.1 0-4 MEP w mi W WATER NEA ABOVE MOF FLOOR PLAN — WATER PIPING WORK SCALE: 1/411 = 1'-0" FI OOR PLAN — WASTE AND VENT PIPING WORK SCALE: 1/4" = 1'-0" W D18 1--i D17 c/ P4 W.-•4 Coco Un W p —ooi C\2 ao c� WaArk� pm� z ~ �-+ H ,,� O o `I rT w Z ;'" c CONNECT TO LL.'S F5 (m Zei c0 C\2 r� o �A ��wco SAN. STUB- VERIFY L.L'S 4" SAN. EXACT LOCATION I IN FIELD W.C.. 1LAV1 I I I I 4" W. t 2" V. 4" F.D. I I I I W/ C.O. I I � CONNECT TO LL.'SI I IN I 2" IN. I " FID. VENT STUB- VERIFY „ 1 1/ IV. / ¢.0. EXACT LOCATION IN FIELD — I .... J I OP SIN 3" W. 1 1/2- V. C.O. I I I DD I I , 3COMPARTMENT SINK I I I I I 2" W. 11/2" V. D D .1 I SINK I 2" W. 1 1/2' V. I SYMBOLS AND ABBREVIATIONS W.C. LAV. WATER CLOSET LAVATORY I F.D. 4, v 111 D ` I W W/ MS MOP SINK SAN. SANITARY SEWER I W. WASTE V. VENT I I C.W. COLD WATER I H.W. HOT MATER ( J I F.W. FILTERED WATER DRAIN F.D. ' p F.D. FLOOR w/ C.O. W C.O. CLEAN OUT SINK I 2" W. 1 1/2' V. O I .0 � ] H DE 2" F.D. of----� C.O. 2" F.D. 0E. W/ C.O. _ FI OOR PLAN — WASTE AND VENT PIPING WORK SCALE: 1/4" = 1'-0" J J Q m � o m N Z:) o N W w z FW- U Q �* �r 0 Lu un ,n N co 00 aIW -Ui+ 4Qao�C U�u GEL04002 W 1--i c/ P4 W.-•4 Coco Un W p cc I I C\2 ao c� WaArk� pm� z ~ �-+ z Cf ,,� O o `I rT w Z ;'" c F+i F5 (m Zei c0 C\2 r� o �A ��wco J J Q m � o m N Z:) o N W w z FW- U Q �* �r 0 Lu un ,n N co 00 aIW -Ui+ 4Qao�C U�u GEL04002 WATER HEATER ON PLATFORM ABOVE MOP SINK 1" DRAIN DOWN TO MOP SINK WITH APPROVED AIR GAP EXPANSION TANK 3/4"-n LANDLORD PROVIDED 1" COLD WATER PIPE TO SPACE (VERIFY EXACT LOCATION IN FIELD PRIOR TO BID) 3/4" SINK l (FILTERED WATER) LAV. 3 COMPARTMENT SINK BALL VALVE WITH 3/4" HOSE CONNECTOR <1 SINK SINK SINK ICE MAKER (FILTERED WATER) IN FLOOR 3/4" 3/4" DIPPER WELL COFFEE MAKER �IN FLOOR DIPPER WELL �— 3/4" ESPRESE (FILTER DIPPER WELL R 3/4- 7 F L O O R P L A N — WATER PIPING W O R I� IN FLOOR /no SCALE: 1/411 = 1'-0" THROUGH FLOOR (TYPICAL) SYMBOLS AND ABBREVIATIONS W.C. WATER CLOSET LAV. LAVATORY MS MOP SINK SAN. SANITARY SEWER W. WASTE V. VENT C.W. COLD WATER H.W. HOT WATER F.W. FILTERED WATER F.D. FLOOR DRAIN C.O. CLEAN OUT LANDLORD PROVIDED 2" VENT PIPE TO \ SPACE (VERIFY EXACT LOCATION IN X FIELD PRIOR TO BID) 2" 1 1/2" 1 1/2" -_---- LANDLORD PROVIDED 4" SANITARY PIPE TO SPACE (VERIFY EXACT LOCATION IN FIELD PRIOR TO BID) SINK 1 1/2- 2" F.D. W/ C.O. FLOOR PLAN — WASTE AND VENT PIPING WORK SCALE: 1/411 1'-0" N �PNC00 'E 600 h -■1 W C\2CO .--4 u -Z W .•--� CO Cc co CSO CC\2 I I Th z z H ►-^ 2 2 0 (v .-•� o o p U O wzz°�w za -!4=C� �� o �= v-LnPr-4co z•_..� Cp O v N �PNC00 'E 600 �1S.pR0% J J Q m M N D o U UJ of m z F u p o 0 ii �) Lu N 00 00 GELO4OO2 P-2