Loading...
HomeMy WebLinkAbout04090032 Building PlansABBREVIATIONS AFF ABOVE FINISHED FLOOR JC JANITOR'S CLOSET ACC ACCESS JT JOINT ACOUS ACOUSTICAL JST JOIST ADD ADDENDUM KIT KITCHEN ADN ADHESIVE OWNER: ADJ ADJACENT LBL LABEL AGG AGGREGATE LAB LABORATORY A/C AIR CONDITIONING LAD LADDER ALT ALTERNATE LAM LAMINATE(D) ALUM ALUMINUM LAV LAVATORY ANCH ANCHORANCHORAGE LH LEFT HAND AB ANCHOR BOLT L LENGTI4 ANDD ANODIZED LTL LINTEL ARCH ARCWITECT (URAL) LL LIVE LOAD ASPI-I ASPHALT LVR LOUVER AUTO AUTOMATIC MH MANHOLE 55MT BASEMENT MFR MANUFACTURE(R) BO BOARD MAS MASONRY BRCS BEARING MO MASONRY OPENING 5RS PL BEARING PLATE MAT MATERIAL (5) BM BEAM MAX MAXIMUM BLK BLOCK MECW MECWANIC(AL) BLKG BLOCKING MED MEDIUM BRD BOARD MTL METAL BS BOTH SIDES MTL/FUR METAL FURRING: BOT BOTTOM MIN MINIMUM BLDG. BUILDING MISC MISCELLANEOUS BO BY OTHERS MLD MOLDING, MOULDING MOV MOVABLE CAB CABINET MULL MULLION CI CAST IRON NAT NATURAL CIPC CAST -IN-PLACE CONCRETE N NORTH CB CATCH BASIN NIC NOT IN CONTRACT CLG CEILING NT5 NOT TO SCALE GER CERAMIC OC ON CENTER($) CT CERAMIC TILE OPNG OPENING CMU CONCRETE MASONRY UNIT OFF OPPOSITE CLR CLEAR (ANCE) OPW OPPOSITEWAND COL COLUMN OD OUTSIDE DIAMETER COMP COMPOSITION (COMPOSITE) O.F.C.I. OWNER FURNISHED CONTRACTOR INSTALLED GONG CONST CONCRETE CONSTRUCTION PTD PAPER TOWEL DISPENSER CONT CONTINUOUS,CONTINUE PVMT PAVEMENT CONTR CONTRACT (OR) PED PEDESTAL CJ CONTROL JOINT PERF PERFORATE (D) CORR CORRUGATED PLAS PLAM PLASTER PLASTIC LAMINATE CL CENTER LINE PL PLATE DL DEAD LOAD PWD PLYWOOD DEMO DEMOLISH, DEMOLITION PSF POUNDS PER SQUARE FOOT DTL DETAIL PSf POUNDS PER SQUARE INCH DIA DIAMETER PREFIN PREFINISHED DIAD DIAGONAL PL PROPERTY LINE DIM DIMENSION QB QUARRY BASE DN DOWN Qt QUARRY TILE DR DOOR DS DOWNSPOUT DT DRAIN TILE RAD RADIUS DWG DRAWING REF REFERENCE DF DRINKING FOUNTAIN REFR REFRIGERATOR REG REGISTER EJ EXPANSION JOINT J REINF REINFORCE(D),(fNG) EJ EXPANSION RES RESILIENT EWC ELECTRIC WATER COOLER RA RETURN AIR ELEV ELEVATION/ELEVATOR REV REVISIONCS),REVISED EMER EMERGENCY RI4 RIGHT HAND EXW EXHAUST R RISER EX/EXIST EXISTING RD ROOF DRAIN EB EXPANSION BOLT RFG ROOFING EXPN ANC EXPANSION ANCHOR RM ROOM EXP EXPOSED RO ROUGH OPENING EXT EXTERIOR RB RUBBER BASE EIFS EXTERIOR INSULATED RT RUBBER TILE FINISH SYSTEM SCWED SCWEDULE FB FACE BRICK SEC SECTION FAST FASTEN (ER) SWT SWEET FIN FINISW(ED) SIM SIMILAR FE FIRE EXTINGUISHER SLV SLEEVE FH FIRE HYDRANT SC SOLID CORE FHC FIRE HOSE CABINET S SOUTH FP FIREPROOF SPEC SPECIFICATION(S) FLSH FLASHING SQ SQUARE FLEX FLEXIBLE 85 STAINLESS STEEL FLR FLOORING) STD STANDARD FD FLOOR DRAIN STL STEEL FTG FOOTING ST. DR. STORM DRAIN FND FOUNDATION STRUCT STRUCTURAL FR FRAME (D),(ING) SUSP SUSPENDED FUR FURRED (ING) 5Y5 6Y5TEM PUT FUTURE GA GAGEJGAUGE THK THICK (NESS) GALV GALVANIZED TH THRESHOLD GC GENERAL CONTRACT(OR) TOS TOP OF STEEL GL GLA55;3LAZING T TYP TREAD TYPICAL GL BLK GLASS BLOCK GB GRAB BAR U.L. UNDERWRITER'S LABORATORY GD GRADE, GRADING UNO UNLESS NOTED OTHERWISE GYP GYPSUM UR URINAL GYP BD GYPSUM BOARD VB VAPOR BARRIER WD HEAD VERT VERTICAL WDW HARDWARE VIN VINYL WWD HARDWOOD VB VINYL BASE WGT WEIGHT VF VINYL FABRIC WVAC WEATING/VENTILATING VT VINYL TILE AIR GOND. HC HOLLOW CORE WC WATER CL05ET HM HOLLOW METAL WTRPRFG WATERPROOFING WOR HORIZONTAL WW WATER NEATER W5 HOSE BIBS WWF WELDED WIRE FABRIC W WIDTW, WIDE INCL INCLUDE(D),(ING) WIN WINDOW ID INSIDE DIAMETER WD WOOD INS INSULATE(D)PON) INT INTERIOR t AND t ANGLE m AT CENTERLINE O DIAMETER/ROUND • POUND/NUMBER DRAFTING SYMBOLS, i�LEVATION OR rRK POINT UVER REFERENCE wlWINDOW REFERENCE EXTERIOR ELEVATION A�fd3 REFERENCE 35 ZD A601 INTERIOR ELEVATION REFERENCE l� NAME ROOM IDENTIFICATION 101 ORTH ARROW NORT4 q WALL TYPE 14 PLAN KEYNOTE DEMOLITION KEYNOTE DOOR SYMBOL NEW DOOR (EXISTING TO BE NOTED) WALL AND / OR DOOR I_ f; TO BE REMOVED J SECTION REFERENCE A3fdb BUILDING SECTION A3W DETAIL REFERENCE GYPSUM BOARD/ PLASTER CEILINGS FLOOR }=LAN DRAWING TITLE SCALE: I/8' ■ I'-0' 15 E TA I L DETAIL REFERENCE A-1 SCALE:I/8'■I'-0' - - - - - - PROPERTY LINE MATERIAL LEGEND CONCRETE MASONRY UNIT BRICK ' CONCRETE RIGID INSULATION BATT INSULATION ® WOOD BLOCKING WOOD SHIMS FINISH• CARPENTRY 77-� STEEL PLYWOOD GRANULAR FILL/ GRAVEL BED UNDISTURBED SOIL/ SOIL BACKFILL LM= CERAMIC OR QUARRY TILE CARPET ACOUSTICAL TILE CEILING: DRAWING INDEX A-0.1 TITLE SWEET ARCHITECTURAL A-1.1 PLANS - FLOOR, CEILING 4 EQUIPMENT A-1.2 DETAILS - ELEVATIONS 4 SECTIONS MECHANICAL 4 ELECTRICAL M-1.1 HVAC PLAN E-1 ELECTRICAL PLAN CODE SUMMARY: LOCATION: CLASSIC CLEANERS a CLAY TERRACE CLAY TERRACE BOULEVARD, SUITE 160 CARMEL, INDIANA 46032 OCCUPANCY CLASSIFICATIONS: MERCANTILE (RETAIL SHOPS) GROUP M OCCUPANCY (309.1) - PREVIOUSLY 'B' CONSTRUCTION TYPE: TYPE II , BASED UPON ALLOWABLE AREA (504.505) REFER TO BUILDING SWELL DOCUMENTATION BY OTHERS ALLOWABLE AREEA:BASIC ALLOWABLE: TABLE 503 REFER TO BUILDING SHELL DOCUMENTATION BY OTHERS BUILDING ELEMENTS: BUILDING ELEMENTS, INCLUDING STRUCTURAL FRAME, BEARING WALLS, INTERIOR PARTITIONS 4 TENANT DEMISING WALLS ARE OF NON-COMBUSTIBLE CONSTRUCTION. TENANT DEMISING WALLS ARE ONE WOUR CONSTRUCTION. AUTOMATIC SPRINKLERS: AUTOMATIC SPRINKLERS ARE REQUIRED. DESIGN WILL BE SUBMITTED SEPARATELY BY PROJECT SPRINKLER DESIGNER FIRE ALARM SYSTEM: FIRE ALARM SYSTEM IS REQUIRED, DESIGN TO BE SUBMITTED SEPARATELY (1001.2.8, IFC) SMOKE DETECTORS: SMOKE DETECTORS ARE REQUIRED FOR WVAC SHUTDOWN FOR SYSTEMS DELIVERING IN EXCESS OF 2000 CFI1(606.1, IMG) TENANT NOTE: THIS TENANT SPACE IS 101 S.F. AND WILL BE OCCUPIED BY CLASSIC CLEANERS. GROUP 'M' OCCUPANCY GENERAL PROJECT NOTES: 1. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, LICENSES AND CERTIFICATES AS REQUIRED BY ALL GOVERNING AGENCIES AND CODE JURISDICTIONS. . ALL WORK SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL REQUIREMENTS FOR ALL PORTIONS OF THE REQUIRED WORK, BY ALL TRADES. 3, CONTRACTOR SHALL CLOSELY COORDINATE WITH OWNER FOR ACCE55 TO SPACES, TEMPORARY UTILITIES AND TEMPORARY PARTITIONS, DUMPSTER LOCATION, SECURITY AND SCHEDULE. 4. CONTRACTOR SHALL REMOVE ALL DEMOLISHED MATERIALS FROM TWE SITE AS REQUIRED AND CLEAN OWNER'S PREMISES FROM ALL DEBRIS AND DIRT AS REQUIRED PER OWNER'S GUIDELINES. 5. CONTRACTOR SWALL COORDINATE OWNER'S EQUIPMENT INSTALLATIONS AND COORDINATE WITH OWNER'S TELECOMM t SECURITY VENDORS. PRO SITE WI L D OATS VICINITY MAP NOT TO SCALE CLASSIC CLEANERS, SUITE 160 r<<�► �- SITE PLAN NOT TO SCALE V!OF� i� Reg cA,mp�ianoe 0ca� Gri�S S41119a States aLn 01\0 j St. OEP'T I s H � o z N O N 05 w N oN - C� 41 Z oz cn Oma°o zci � ~� 0 Ell U o U V as o w �a�� uc' Y, tea, w °'U d IF z jz ow F -f O x ° 7 v z W F.r m NORTH A.ZCHITECT CIVRA STONE CRAIG W. kAPP Associates, LLC Architecture GYPSUM BOARD 118WStClarSt Indianapolis, IN 46204 Ph 317/423-45 PLASTER ON Emil: METAL LATH DRAWING INDEX A-0.1 TITLE SWEET ARCHITECTURAL A-1.1 PLANS - FLOOR, CEILING 4 EQUIPMENT A-1.2 DETAILS - ELEVATIONS 4 SECTIONS MECHANICAL 4 ELECTRICAL M-1.1 HVAC PLAN E-1 ELECTRICAL PLAN CODE SUMMARY: LOCATION: CLASSIC CLEANERS a CLAY TERRACE CLAY TERRACE BOULEVARD, SUITE 160 CARMEL, INDIANA 46032 OCCUPANCY CLASSIFICATIONS: MERCANTILE (RETAIL SHOPS) GROUP M OCCUPANCY (309.1) - PREVIOUSLY 'B' CONSTRUCTION TYPE: TYPE II , BASED UPON ALLOWABLE AREA (504.505) REFER TO BUILDING SWELL DOCUMENTATION BY OTHERS ALLOWABLE AREEA:BASIC ALLOWABLE: TABLE 503 REFER TO BUILDING SHELL DOCUMENTATION BY OTHERS BUILDING ELEMENTS: BUILDING ELEMENTS, INCLUDING STRUCTURAL FRAME, BEARING WALLS, INTERIOR PARTITIONS 4 TENANT DEMISING WALLS ARE OF NON-COMBUSTIBLE CONSTRUCTION. TENANT DEMISING WALLS ARE ONE WOUR CONSTRUCTION. AUTOMATIC SPRINKLERS: AUTOMATIC SPRINKLERS ARE REQUIRED. DESIGN WILL BE SUBMITTED SEPARATELY BY PROJECT SPRINKLER DESIGNER FIRE ALARM SYSTEM: FIRE ALARM SYSTEM IS REQUIRED, DESIGN TO BE SUBMITTED SEPARATELY (1001.2.8, IFC) SMOKE DETECTORS: SMOKE DETECTORS ARE REQUIRED FOR WVAC SHUTDOWN FOR SYSTEMS DELIVERING IN EXCESS OF 2000 CFI1(606.1, IMG) TENANT NOTE: THIS TENANT SPACE IS 101 S.F. AND WILL BE OCCUPIED BY CLASSIC CLEANERS. GROUP 'M' OCCUPANCY GENERAL PROJECT NOTES: 1. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, LICENSES AND CERTIFICATES AS REQUIRED BY ALL GOVERNING AGENCIES AND CODE JURISDICTIONS. . ALL WORK SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL REQUIREMENTS FOR ALL PORTIONS OF THE REQUIRED WORK, BY ALL TRADES. 3, CONTRACTOR SHALL CLOSELY COORDINATE WITH OWNER FOR ACCE55 TO SPACES, TEMPORARY UTILITIES AND TEMPORARY PARTITIONS, DUMPSTER LOCATION, SECURITY AND SCHEDULE. 4. CONTRACTOR SHALL REMOVE ALL DEMOLISHED MATERIALS FROM TWE SITE AS REQUIRED AND CLEAN OWNER'S PREMISES FROM ALL DEBRIS AND DIRT AS REQUIRED PER OWNER'S GUIDELINES. 5. CONTRACTOR SWALL COORDINATE OWNER'S EQUIPMENT INSTALLATIONS AND COORDINATE WITH OWNER'S TELECOMM t SECURITY VENDORS. PRO SITE WI L D OATS VICINITY MAP NOT TO SCALE CLASSIC CLEANERS, SUITE 160 r<<�► �- SITE PLAN NOT TO SCALE V!OF� i� Reg cA,mp�ianoe 0ca� Gri�S S41119a States aLn 01\0 j St. OEP'T I s H � o z N O N 05 w N oN - C� 41 Z oz cn Oma°o zci � ~� 0 Ell U o U V as o w �a�� uc' Y, tea, w °'U d IF z jz ow F -f O x ° 7 v z W F.r m NORTH A.ZCHITECT CIVRA CRAIG W. kAPP Associates, LLC Architecture - Planning - Interiors 118WStClarSt Indianapolis, IN 46204 Ph 317/423-45 99 Fax 317/423-4996 Emil: cwrappassociates(i w.can PROJECT NUMBER s 405ZO OWNER: CLASSIC CLEANERS >m 0 �o H 1 'd U a w w W U � H �) W O kn kn d" U - 3336 STATE OF s �t T1Pi A N e�leaT �E TITLE SHEET 11tM01Gtdt'J ala, KTA. PALM 1/6/04 ommmw. C 04mm.n.. AVa 0.1 HW 8UPPLY TO SYSTEM SEE PLAN � — CW SUPPLY TO WATER HEATER SEE I -LAN I = r -OL BALL VALVE UNION DIELECTRIC (TYP) 1 DISCHARGE TIP RELEIF VALVE WATER INTO DRAIN PAN HEATER GALvANMED SHEET METAL •. DRAIN PAN lZ® GA. 11/2' DEEP 'PIPE FULL SIZE TO APPROVED .WATER NEATER DETAIL N.TA INSTALL CONDENSATE TRAP FURNISHED WITH ROOFTOP UNIT DISCHARGE AWAY FROM SERVICE AREAS OF UWT-7 PIPE REDUCER FROM BRANCH PIPE SIZE TO UNIT CONNECTION SIZE. AT UNIT CONNECTION GROUND JOINT PIPE UNiON GAS SHUT-OFF COCK BRANIC14 OFF TOP OF GAS PIPE MAIN LONG DIRT LEG FULL SIZE OF BRANCH PIPE— PIPE-- SUPPORt 8EE BRANCH PIPE SEE PLAN FOR 61M DETAILS ROOFTOP UNIT CONNECTIONS N.T.S. SANITARY RiSER DIAGRAM RTA ELEC RACK BY TENANT OWNER EQUIP., PLUM5., M. 4 E. FLOOR PLAN SCALE: i/4' - 1'-0' GENERAL NOTES: GI. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS G2. OVERALL ROOM DIMENSIONS ARE FROM CENTER OF WALL TO CENTER OF WALL. PERIMETER WALLS ARE ONLY EXCEPTION (OUTSIDE FACE OF WALL). G3. PLUMBING FIXTURES DIMENSIONED FROM FINISHED WALL. G4. ALL UNDERGROUND SANITARY, F.D: S AND GA.'S BY LANDLORD. PLUMBING FIXTURES: P-1 HANDICAP TANK TYPE WATER CLOSET, GERBER °21118 EL COMBO TOILET, BEMIS 01955 C SEAT, 3/8' ODx 5/8' OD ANGLE SUPPLY KiT t WAX RING. P-2 HANDICAP WALL HUNG LAVATORY, GERBER 012654 20x 18 CHINA LAVATORY, DELTA 0501 LAYATORI' FAUCET, INSULATION KIT ADA, I I/4' TRAP < 3I8' Opx 5/8' OD ANGLE SUPPLY KiT. P-3 STUBBED 4' DRAIN BY LANDLORD- SEE SHELL BUILDING PLUMBING P-4 FLOOR DRAM, 2' PVC WITH NB TOP. P-5 NOT USED P-6 INSTANTANEOUS ELECTRIC WATER HEATER EE MAX. 110 VOLT. PLUMBING SPECIFICATIONS THE WORK INCLUDES PROVIDING NEW MATERIALS, FITTINGS AND ACCESSORIES NECESSARY FOR A COMPLETE FUNCTIONING PLUMBING SYSTEM. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND/ OR ORDINANCES AND IS SUBJECT TO INSPECTION CONTRACTOR SHALL PAY HOOKUP CHARGES, PERMITS, AND ALL OTHER EXPENSES RELATED TO THE PLUMBING SYSTEM. PIPING SYSTEMS -GENERAL. PIPING SHALL BE RISA PARALLEL t0 BUILDING LINES AND SUPPOR'T'ED AND ANCHORED AS REQUIRED t0 FACILITATE EXPANSION AND CONTRACTION. ALL PIPING SHALL BE CONCEALED EXCEPT IN UNFINISHED SPACES. INSTALL AS REQUIRED t0 MEET ALL CONSTRUCTION CONDITIONS AND t0 ALLOW FOR INSTALLATION OF OTHER WORK SUCH AS DUCTS AND ELECTRICAL CONDUIT. At ALL CONNECTIONS BETWEEN FERROUS PiPING AND NONFERROUS PIPING, PROVIDE AN ISOLATING DIALECTIC UNiON. ALL HANGERS SHALL BE COMPATIBLE WITH PIPING MATERIAL TO PREVENT CORROSION. PROVIDE ALL FITTINGS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY TO FACILITATE THE PLUMBING SYSTEM'S FUNCTIONING AS INDICATED BY TWE DESIGN AND THE EQUIPMENT INDICATED. SEWER AND WASTE PiPING; PROVIDE ALL DRAINS AND SEWER WITHIN THE BUILDING WITH CONNECTION t0 THE ON-SITE SANITARY DRAINAGE SYSTEMS. SANITARY DRAINAGE PIPING ABOVE PVC IF ALLOWED BY LOCAL CODES. ALL DRAINAGE PIPING SHALL BE UNIFORMLY PiTCHED, 1/4' PER FOOT UNLESS OTHERWISE REQUIRED BY EXISTING CONDITIONS, OR INDICATED ON THE DRAWINGS. PLASTIC VENT SYSTEMS IN RETURN AIR PLENLM ARE ALLOWED. VENT SYSTEMS SHALL BE CARRIED THROUGH THE ROOF WITH APPROPRIATE FLASHING. STORM SEWER PIPING: PROVIDE ALL DRAINS AND SEWERS WITHIN THE BUILDING WITH CONNECTION TO THE ON-SITE STORM SEWER SYSTEMS. STORM SELLER PIPING ABOVE FLOOR AND STORM SEILER PIPING BELOW GRADE SHALL BE PVC IF ALLOWED BY LOCAL CODES. ALL STORM SEWER PIPING SHALL BE REQUIRED BY UNIFORMLY PITCHED, 1/4' PER FOOT UNLESS OTHERWISE REQUIRED BY EXISTING CONDITIONS, OR INDICATED ON THE DRAWINGS. CONDENSATE AND INDIRECT DRAIN PIPING: PROVIDE PVC TUBING CLEANOUTS: PROVIDE CLEANOUTS AT ENDS OF EACH HORIZONTAL RLN, AND AT BASE OF ALL VERTICAL WASTE AND DRAM PIPES. CLEANOUTS SHALL BE OF SAME SIZE AS PIPES THEY SERVE, CONFORMING TO CODE REQUIREMENTS. PROVIDE SUITABLE WALL OR FLOOR CLEANOUTS WITH ACCESSORIES TO OBSCURE P1001 VIEW. WATER DISTRIBUTION PIPING: HOT AND COLD WATER PIPING SHALL BE 1/2' MINIMUM, TYPE L COPPER TUBING WITH WROUGHT COPPER FITTINGS AND SWEAT CONNECTIONS. PROVIDE WATER HAMMER ARRESTERS AT EACH FIXTURE OR GROUP OF FIXTURES AS REQUIRED. INSTALL CHROME PLATED GRASS ESCUTCHEON PLATES AT ALL PENETRATIONS THROUGH FINISHED SURFACES (INCLUDING CABINET INTERIORS). USE TM ANTIMONY SOLDER 95/5 FOR ALL SWEAT FITTINGS OF COPPER PIPING. PIPE INSULATION: INSULATE ALL LISTED SERVICE PIPING AS FOLLOWS, DOMESTIC COLD/NOT WATER STORM WATER PIPING. PROVIDE 1' PRE-FOFIMED FIBERGLASS, ASJ/66-11, FLAME SPREAD 25, SMOKE DEVELOPED 50, ASTM C-541. WHERE PERMITTED BY LOCAL CODES, PROVIDE 1/2' SELF-ADHESIVE UNICELLULAR FOAM PIPE INSULATION WiTH PRE -FORMED PVC FIMNG COVED EQUAL TO SELF-ADHESIVE ARMSTRONG 2000 WITH K FACTOR OF 021 AT 15 WASTE TEMPERATURE BELOW 60 DEGREES F. PROVIDE SHUTOFF VALVES FOR SERVICE TO EACH PLUMBING FIXTURE, AR EQUIPMENT ITEM, TO FACILITATE ISOLATION FOR REPAIR OR REPLACEMENT. VALVES SHALL BE EQUAL TO JENKINS 0002-T BALL VALVE, CHROME -FINISHED BRONZE, TEFLON SEATS AND PACKING, 400 LB. WANG., SOLDER END. PROVIDE ACCESS PANELS WHEiRE CONCEALED CONTROL DEVICES, VALVES, ETCETRA ARE CONCEALED WITHIN WALLS. WHERE ACCESS FOR ADJUSTMENT AND MAINTENANCE IS POSSIBLE THROUGH LAY -IN SUSPENDED CEILING, OMIT ACCESS PANELS. INSTALLATION-. THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION. CAP PIPE OPENINGS TO EXCLUDE DiRT UNTIL FIXTURES ARE INSTALLED AND FINAL CONNECTIONS ARE MADE. SET FIXTURES LEVEL AND IN PROPER ALIGNMENT. INSTALL SUPPLIES M PROPER ALIGNMENT WITH FIXTURES. INSTALL SILICONE SEALANT BETWEEN FIXTURES AND ADJACENT SURFACE. GYP. 50. CEILING 49 15'-0' APP., PAINT, PERIM. TROFFER W/ PERIM. TROFFER SEE DETAIL Is/A-2.1 COSTOMER SERVICE COUNTER, PURNIS14ED AND INSTALLED BY TENANT ------- CEILING --CEILING HUNG LIGHT FIXTURES I / OO ER SERVICE COUNTERS,T. LEASE LINE AT CENTER LINE OF TENANT DEMISING WALL, TYP. — LEASE LINE: EXTENT OF TENANT'S STOREFRONT 2'x 4' SUSPENDED LAY -IN CEILING. 2'x 2' LAY -IN FIXTURE, BY EC —\ or TENANT CODE SUMMARY: Location: Classic Cleaners at Clay Terrace Clay Terrace Boulevard, Space A01 Carmel, Indiana Code: 2003 Indiana Building Code Occupancy: Mercantile Group 'B' Retell t Service (304 t 309) i Construction type: Ii -B (Sprinkled) Interior Finlehes: Chapter 8, Class C Sprinkler, Alarm t Detectors, Refer to Base Building Summary 39'-4 9/16' ff 3 Asa NEW 4' coNG1RETE SLAB oN GRADE, REIN. w/6x6-W1AxWl.4 W.W.F. ON 6 MIL. VAPOR BARRIER OVER 4' (MIN.) OF COMPACTED 053 STONE. (SEE 2/A2.1) STORAGE EDGE OF EXISTING CONCRETE SLAB ON GRADE EXISTING RE -BAR, RE POSITION AS REQUIRED - EXiST. DOWN SPOUT t GLEAN -OUT PURR w/ MA 15/8' - G.B„ PROVIDE 8'x8' A( A ACCESS DOOR is Ata CLEAN-OUT FLOOR PLAN SCALE: 1/4' ■ 1'-0' GENERAL NOTES I. All Wood Trim Shall Be White Pine or Birch Veneer and Stained To Match Tenant's Casework Laminate Tops (Wilson Art 1054-60 'Wild Cherry'). CONTRACTOR SHALL SUBMIT SAMPLE 1=0R OWNER APPROVAL. 2. Provide 5/8' TcWe 'X' Gyp. Bd. from Slab to Deck Above At All Exterior Wall* And All Demising Walls.- Paint All Wall Surfaces. 3. Contractor Shall Coordinate All Work With Landlord And Owner Ar Required And Engage Landlord's Roofer And Sprinkler Contractor's for Related Work of This Contract. 4. Contractor Shall Cloeely Coordinate All Work With Owner And With Owner a Equipment Rsquirements. 5. Contractor to Verify with Owner and Provide all Necessary Surface Applied Blocking Required for Installation of Owner Supplied and Installed Equipment. 6. Contractor shall provide 36' a 42' ADA grab bars, mirrlr, tissue t paper towel disp. in restroom. I HOUR PARTITION: U.L. DESIGN 011465 I -LAYER 5/8' GWJ5. EA. SIDE 6' MTL. STUDS. T_ 4 s 2 EDGE OF C ONCRETE WALL AT FLOOR -- _ ELEVATION CHANGE - LEASE LINE AT OUTSIDE FACE OF EXTERIOR WALL DOOR SCPEDULE 101A 3'-0' x 1'-0' Aluminum Entry Door and Frame to Match New Storefront. Provide push/Pull w/ Deadbolt And LCN Closer. Locking Hardware to Accept 6 Pin Best Core t Closer. 1018 Cased (Wood) Door Opening, 3'-b' x 1'-0', Finished Door Head 1'-0' . 3 1/4' Beaded Casing on Customer Service Side, Std. 2 1/4' Colonial Casing on Storage Side. Door Jambe 'Finger Fluted', See Detail This Sheet. ® V-0' x 1'-0' HM Frame w/ Solid Core, Birch Veneered, Wood Door (Stain). Privacy Lock t Door Stop. (Stained) 1"'001 C WALLS CRAIG W. RAPP Arcbibachlre 4' SANITARY BY L.L. 118 w. sr. (ar'rft bdimmolhON46204 Pk 317/423.4999 F 8414111: 317/423-1996 NOTE: (EtG. MAKE ALL CONN. AFTER 5A5E SPR LiNE STUBBED BY L.L. SPR CEILING HFiGHT REMARK& OWNER'S EQUiP. IN PLACE) NAh'Ir= OMTR. VSIM LEX GRINNELL') TO DY L.L. S UJ A01-01 L055Y EXTEND SYS. t SUBMIT DESIGNA WOOD P-I,WC-1 P-I,ur_-I P-I'Wr--I P-I,l11C-I GYP. 5D. /PAINT DOCUMENTS TO RESPECTIVE I, 2, 4 A01-02 STORAGE SEALED GONG 4' V TYR HAMPER BY TENANT (5) JURISDICTION. P P 5-JOIST/DECK - PAINT - 4 AOI -03 TOILET VCT 4' V P P P P ACOUSTIC, 2x4 8' 3, 4 1. WALL COVERING (WC -1) FURNISHED BY OWNER INSTALLED BY CONTRACTOR 28' X 60' X 36' H. WORK GTR BY TENANT TYP. 18' X 48' SHELVES BY TENANT C) EXISTING 4' PVC VENT THRU ROOF U4ndam' llltt//Ij,,'''//i _.... 3 6 STATE 20 AMP I$OL. GRC. mom► Foeecwx-now FLOOR, CEiLINCs t EQUIP. iawia� AS NOTED °N` -i /(o /04 3/8' CA_ OWNER'SOMPUI cl�>iuR� Cm CUR --- ---------- I Al. �- --M +40 AFF �..___. _ ' � ---_ _.... _. 2' VENT TO ROOF ' I , 20 AMP tSOL. GRD FOR ; OILNER'S COMPUTED R1C1 "BY MC — _.. P-6, ABOVE CEILING TOILET 3/8' Call. I 3/8' 140. I I P-2 DATA/V0 CE I`. 3/4' C. IN SLAB ;' L. PANEL I'C (TELEPHONE) BY LL. 48 LINTER SLOT DI SIRS, 4 SANITARY STUB BY L.L. BY tiq.LOBBY I S(MODIFY AS REQUIRED) E EG. PANEL I I/2'C (ELECT) r, I I A01-01 � BY LL. 1/2 SW TCHED, IN Bt. OF LIGHT I T R FOR OPEN SIGN IZOY FOR 1/2 HP MIR (20 AMP) S�It C44T LOW OLT`CA1ti LfCxF#tH�v L HW 8UPPLY TO SYSTEM SEE PLAN � — CW SUPPLY TO WATER HEATER SEE I -LAN I = r -OL BALL VALVE UNION DIELECTRIC (TYP) 1 DISCHARGE TIP RELEIF VALVE WATER INTO DRAIN PAN HEATER GALvANMED SHEET METAL •. DRAIN PAN lZ® GA. 11/2' DEEP 'PIPE FULL SIZE TO APPROVED .WATER NEATER DETAIL N.TA INSTALL CONDENSATE TRAP FURNISHED WITH ROOFTOP UNIT DISCHARGE AWAY FROM SERVICE AREAS OF UWT-7 PIPE REDUCER FROM BRANCH PIPE SIZE TO UNIT CONNECTION SIZE. AT UNIT CONNECTION GROUND JOINT PIPE UNiON GAS SHUT-OFF COCK BRANIC14 OFF TOP OF GAS PIPE MAIN LONG DIRT LEG FULL SIZE OF BRANCH PIPE— PIPE-- SUPPORt 8EE BRANCH PIPE SEE PLAN FOR 61M DETAILS ROOFTOP UNIT CONNECTIONS N.T.S. SANITARY RiSER DIAGRAM RTA ELEC RACK BY TENANT OWNER EQUIP., PLUM5., M. 4 E. FLOOR PLAN SCALE: i/4' - 1'-0' GENERAL NOTES: GI. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS G2. OVERALL ROOM DIMENSIONS ARE FROM CENTER OF WALL TO CENTER OF WALL. PERIMETER WALLS ARE ONLY EXCEPTION (OUTSIDE FACE OF WALL). G3. PLUMBING FIXTURES DIMENSIONED FROM FINISHED WALL. G4. ALL UNDERGROUND SANITARY, F.D: S AND GA.'S BY LANDLORD. PLUMBING FIXTURES: P-1 HANDICAP TANK TYPE WATER CLOSET, GERBER °21118 EL COMBO TOILET, BEMIS 01955 C SEAT, 3/8' ODx 5/8' OD ANGLE SUPPLY KiT t WAX RING. P-2 HANDICAP WALL HUNG LAVATORY, GERBER 012654 20x 18 CHINA LAVATORY, DELTA 0501 LAYATORI' FAUCET, INSULATION KIT ADA, I I/4' TRAP < 3I8' Opx 5/8' OD ANGLE SUPPLY KiT. P-3 STUBBED 4' DRAIN BY LANDLORD- SEE SHELL BUILDING PLUMBING P-4 FLOOR DRAM, 2' PVC WITH NB TOP. P-5 NOT USED P-6 INSTANTANEOUS ELECTRIC WATER HEATER EE MAX. 110 VOLT. PLUMBING SPECIFICATIONS THE WORK INCLUDES PROVIDING NEW MATERIALS, FITTINGS AND ACCESSORIES NECESSARY FOR A COMPLETE FUNCTIONING PLUMBING SYSTEM. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND/ OR ORDINANCES AND IS SUBJECT TO INSPECTION CONTRACTOR SHALL PAY HOOKUP CHARGES, PERMITS, AND ALL OTHER EXPENSES RELATED TO THE PLUMBING SYSTEM. PIPING SYSTEMS -GENERAL. PIPING SHALL BE RISA PARALLEL t0 BUILDING LINES AND SUPPOR'T'ED AND ANCHORED AS REQUIRED t0 FACILITATE EXPANSION AND CONTRACTION. ALL PIPING SHALL BE CONCEALED EXCEPT IN UNFINISHED SPACES. INSTALL AS REQUIRED t0 MEET ALL CONSTRUCTION CONDITIONS AND t0 ALLOW FOR INSTALLATION OF OTHER WORK SUCH AS DUCTS AND ELECTRICAL CONDUIT. At ALL CONNECTIONS BETWEEN FERROUS PiPING AND NONFERROUS PIPING, PROVIDE AN ISOLATING DIALECTIC UNiON. ALL HANGERS SHALL BE COMPATIBLE WITH PIPING MATERIAL TO PREVENT CORROSION. PROVIDE ALL FITTINGS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY TO FACILITATE THE PLUMBING SYSTEM'S FUNCTIONING AS INDICATED BY TWE DESIGN AND THE EQUIPMENT INDICATED. SEWER AND WASTE PiPING; PROVIDE ALL DRAINS AND SEWER WITHIN THE BUILDING WITH CONNECTION t0 THE ON-SITE SANITARY DRAINAGE SYSTEMS. SANITARY DRAINAGE PIPING ABOVE PVC IF ALLOWED BY LOCAL CODES. ALL DRAINAGE PIPING SHALL BE UNIFORMLY PiTCHED, 1/4' PER FOOT UNLESS OTHERWISE REQUIRED BY EXISTING CONDITIONS, OR INDICATED ON THE DRAWINGS. PLASTIC VENT SYSTEMS IN RETURN AIR PLENLM ARE ALLOWED. VENT SYSTEMS SHALL BE CARRIED THROUGH THE ROOF WITH APPROPRIATE FLASHING. STORM SEWER PIPING: PROVIDE ALL DRAINS AND SEWERS WITHIN THE BUILDING WITH CONNECTION TO THE ON-SITE STORM SEWER SYSTEMS. STORM SELLER PIPING ABOVE FLOOR AND STORM SEILER PIPING BELOW GRADE SHALL BE PVC IF ALLOWED BY LOCAL CODES. ALL STORM SEWER PIPING SHALL BE REQUIRED BY UNIFORMLY PITCHED, 1/4' PER FOOT UNLESS OTHERWISE REQUIRED BY EXISTING CONDITIONS, OR INDICATED ON THE DRAWINGS. CONDENSATE AND INDIRECT DRAIN PIPING: PROVIDE PVC TUBING CLEANOUTS: PROVIDE CLEANOUTS AT ENDS OF EACH HORIZONTAL RLN, AND AT BASE OF ALL VERTICAL WASTE AND DRAM PIPES. CLEANOUTS SHALL BE OF SAME SIZE AS PIPES THEY SERVE, CONFORMING TO CODE REQUIREMENTS. PROVIDE SUITABLE WALL OR FLOOR CLEANOUTS WITH ACCESSORIES TO OBSCURE P1001 VIEW. WATER DISTRIBUTION PIPING: HOT AND COLD WATER PIPING SHALL BE 1/2' MINIMUM, TYPE L COPPER TUBING WITH WROUGHT COPPER FITTINGS AND SWEAT CONNECTIONS. PROVIDE WATER HAMMER ARRESTERS AT EACH FIXTURE OR GROUP OF FIXTURES AS REQUIRED. INSTALL CHROME PLATED GRASS ESCUTCHEON PLATES AT ALL PENETRATIONS THROUGH FINISHED SURFACES (INCLUDING CABINET INTERIORS). USE TM ANTIMONY SOLDER 95/5 FOR ALL SWEAT FITTINGS OF COPPER PIPING. PIPE INSULATION: INSULATE ALL LISTED SERVICE PIPING AS FOLLOWS, DOMESTIC COLD/NOT WATER STORM WATER PIPING. PROVIDE 1' PRE-FOFIMED FIBERGLASS, ASJ/66-11, FLAME SPREAD 25, SMOKE DEVELOPED 50, ASTM C-541. WHERE PERMITTED BY LOCAL CODES, PROVIDE 1/2' SELF-ADHESIVE UNICELLULAR FOAM PIPE INSULATION WiTH PRE -FORMED PVC FIMNG COVED EQUAL TO SELF-ADHESIVE ARMSTRONG 2000 WITH K FACTOR OF 021 AT 15 WASTE TEMPERATURE BELOW 60 DEGREES F. PROVIDE SHUTOFF VALVES FOR SERVICE TO EACH PLUMBING FIXTURE, AR EQUIPMENT ITEM, TO FACILITATE ISOLATION FOR REPAIR OR REPLACEMENT. VALVES SHALL BE EQUAL TO JENKINS 0002-T BALL VALVE, CHROME -FINISHED BRONZE, TEFLON SEATS AND PACKING, 400 LB. WANG., SOLDER END. PROVIDE ACCESS PANELS WHEiRE CONCEALED CONTROL DEVICES, VALVES, ETCETRA ARE CONCEALED WITHIN WALLS. WHERE ACCESS FOR ADJUSTMENT AND MAINTENANCE IS POSSIBLE THROUGH LAY -IN SUSPENDED CEILING, OMIT ACCESS PANELS. INSTALLATION-. THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION. CAP PIPE OPENINGS TO EXCLUDE DiRT UNTIL FIXTURES ARE INSTALLED AND FINAL CONNECTIONS ARE MADE. SET FIXTURES LEVEL AND IN PROPER ALIGNMENT. INSTALL SUPPLIES M PROPER ALIGNMENT WITH FIXTURES. INSTALL SILICONE SEALANT BETWEEN FIXTURES AND ADJACENT SURFACE. GYP. 50. CEILING 49 15'-0' APP., PAINT, PERIM. TROFFER W/ PERIM. TROFFER SEE DETAIL Is/A-2.1 COSTOMER SERVICE COUNTER, PURNIS14ED AND INSTALLED BY TENANT ------- CEILING --CEILING HUNG LIGHT FIXTURES I / OO ER SERVICE COUNTERS,T. LEASE LINE AT CENTER LINE OF TENANT DEMISING WALL, TYP. — LEASE LINE: EXTENT OF TENANT'S STOREFRONT 2'x 4' SUSPENDED LAY -IN CEILING. 2'x 2' LAY -IN FIXTURE, BY EC —\ or TENANT CODE SUMMARY: Location: Classic Cleaners at Clay Terrace Clay Terrace Boulevard, Space A01 Carmel, Indiana Code: 2003 Indiana Building Code Occupancy: Mercantile Group 'B' Retell t Service (304 t 309) i Construction type: Ii -B (Sprinkled) Interior Finlehes: Chapter 8, Class C Sprinkler, Alarm t Detectors, Refer to Base Building Summary 39'-4 9/16' ff 3 Asa NEW 4' coNG1RETE SLAB oN GRADE, REIN. w/6x6-W1AxWl.4 W.W.F. ON 6 MIL. VAPOR BARRIER OVER 4' (MIN.) OF COMPACTED 053 STONE. (SEE 2/A2.1) STORAGE EDGE OF EXISTING CONCRETE SLAB ON GRADE EXISTING RE -BAR, RE POSITION AS REQUIRED - EXiST. DOWN SPOUT t GLEAN -OUT PURR w/ MA 15/8' - G.B„ PROVIDE 8'x8' A( A ACCESS DOOR is Ata CLEAN-OUT FLOOR PLAN SCALE: 1/4' ■ 1'-0' GENERAL NOTES I. All Wood Trim Shall Be White Pine or Birch Veneer and Stained To Match Tenant's Casework Laminate Tops (Wilson Art 1054-60 'Wild Cherry'). CONTRACTOR SHALL SUBMIT SAMPLE 1=0R OWNER APPROVAL. 2. Provide 5/8' TcWe 'X' Gyp. Bd. from Slab to Deck Above At All Exterior Wall* And All Demising Walls.- Paint All Wall Surfaces. 3. Contractor Shall Coordinate All Work With Landlord And Owner Ar Required And Engage Landlord's Roofer And Sprinkler Contractor's for Related Work of This Contract. 4. Contractor Shall Cloeely Coordinate All Work With Owner And With Owner a Equipment Rsquirements. 5. Contractor to Verify with Owner and Provide all Necessary Surface Applied Blocking Required for Installation of Owner Supplied and Installed Equipment. 6. Contractor shall provide 36' a 42' ADA grab bars, mirrlr, tissue t paper towel disp. in restroom. I HOUR PARTITION: U.L. DESIGN 011465 I -LAYER 5/8' GWJ5. EA. SIDE 6' MTL. STUDS. T_ 4 s 2 EDGE OF C ONCRETE WALL AT FLOOR -- _ ELEVATION CHANGE - LEASE LINE AT OUTSIDE FACE OF EXTERIOR WALL DOOR SCPEDULE 101A 3'-0' x 1'-0' Aluminum Entry Door and Frame to Match New Storefront. Provide push/Pull w/ Deadbolt And LCN Closer. Locking Hardware to Accept 6 Pin Best Core t Closer. 1018 Cased (Wood) Door Opening, 3'-b' x 1'-0', Finished Door Head 1'-0' . 3 1/4' Beaded Casing on Customer Service Side, Std. 2 1/4' Colonial Casing on Storage Side. Door Jambe 'Finger Fluted', See Detail This Sheet. ® V-0' x 1'-0' HM Frame w/ Solid Core, Birch Veneered, Wood Door (Stain). Privacy Lock t Door Stop. (Stained) 1"'001 C WALLS CRAIG W. RAPP Arcbibachlre LLC - IntKim 118 w. sr. (ar'rft bdimmolhON46204 Pk 317/423.4999 F 8414111: 317/423-1996 FLOOR 5A5E O CEILING HFiGHT REMARK& Na NAh'Ir= � � S UJ A01-01 L055Y CERAMIC WOOD P-I,WC-1 P-I,ur_-I P-I'Wr--I P-I,l11C-I GYP. 5D. /PAINT 15' I, 2, 4 A01-02 STORAGE SEALED GONG 4' V P P P P 5-JOIST/DECK - PAINT - 4 AOI -03 TOILET VCT 4' V P P P P ACOUSTIC, 2x4 8' 3, 4 1. WALL COVERING (WC -1) FURNISHED BY OWNER INSTALLED BY CONTRACTOR 2. CERAMIC FLOOR TILE FURNISHED BY OWNER INSTALLED BY CONTRACTOR 3. VCT AND VINYL BASE AS SELECTED BY OWNER 4. PAiNT COLORS AS SELECTED BY OWNER ARCHITEC C CRAIG W. RAPP Arcbibachlre LLC - IntKim 118 w. sr. (ar'rft bdimmolhON46204 Pk 317/423.4999 F 8414111: 317/423-1996 PROJECrWJI> 20405 O NAME CLAM CUW EM W W O W� W w 0 UW U llm� O U4ndam' llltt//Ij,,'''//i 3 6 STATE OF + a mom► Foeecwx-now FLOOR, CEiLINCs t EQUIP. iawia� AS NOTED °N` -i /(o /04 0041040r. IMAM BE cl�>iuR� Cm CUR SIM Al. �- --M r I i' 5/8' GYP. BD. OVER 2 1/2' MTL. STUD • 16' O.C. SUSP. GYP. BD. CEILING BULKHEAD • 15'-0' AFF. -� 2 LAYERS 5/8' GYP. SO. W/ MTL. CASING BEAD * PERIM. OF LOBBY CLG. - PAINT — PERIM. TROFFER SEE DETAIL 5/A2J TENANT'S EXIT SIGN — 2 1/2' STUD w/ 5/8' GYP. — BD, 4 BATT INSULATION AT SPANDREL GLASS PANELS CONC. SLAB 6 MIL. VAPOR BARRIER 2'x48' PERIMETER INSULATION 4' GRANULAR FILL 'LANDLORD'S SLC NEUTRAL COLUMN 12' 1. 12' i 8' SOLDIER COURSE r— re -w [7w Mi UTILITY SIZE BRICK 8' CAST STONE ,�- ACCENT LIG44T BY 'ARK', MODEL AGB -101 OR EQUAL, /-30' ARM, (BLACK FINISH) YANDLORD'S SWELL CONSTRUCTION W/ ALUCOBOND PANELS BOT. OF ALUCOBOND JK 414--W -- PROVIDE I' INSULATED OPAQUE SPANDREL GLASS PANELS ABOVE ALL V-0' 141014 WORIZ MULLIONS. 4' AWNING FABRIC SHALL BE 'SUNBRELLA', 46011 ROYAL BLUE W/ 6 1/2' HIGH WHITE LETTERING. RETURN FABRIC AT END PANELS. ALINING FRAME SHALL BE 1' BLK ALUM, SQ. TUBE w/ CONT. WIELDED JOINTS, ANCHORED TO ALUM. STOREFRONT SECTIONS W/ STD. 'Z' CLIPS 0 ! CLASSIC I UTILITY SIZE BRICK VENEER CLEANERS I 2x4 1/2' ANNODIZED ALUM. TENANT 61 STOREFRONT - COLOR CHAMPAGNE. 4' SILL STARTER AS MFR'D BY KAUNEER SERIES 4500 OR APROVED EQUAL w/ MATCHING DOOR PULL AND HARDWARE. GLASS SHALL SE I' INSULATED UNITS w/ LOW 'E', LIGWT BRONZE COATING, TEMPERED WWERE REQUIRED BY CODE. PROV. SHIMS 4 Of i SEALANT * PERIM., BOTW SIDES. ( 8' ALUM. SILL E SILL STARTER 61 fn 4' CONC. SIDEWALK BY LANDLORD i '4 I FIRST FLOOR 4' GRANULAR FILL 31 5ECTION A2J SCALE: 1/2' = 1'-0' 4 PLAN DETAIL A2J SCALE: 1/2' a I'-0' CONC. FOOTING 4 I/2' ANOO. ALUM. PROV, TREATED WD. SWIMS 4 2x 1/4' SEALANT JT. BOTW SIDES STOREFRONT 1/2, NO 2'x4 1/2' ANNODIZED ANT 2 1/2"MA, 4 ALUM. STOREFRONT CYYF*. BD. COLON CWAMPAGsN9 ~- ,LOSURE 21x4 1/2' ANNODIZED EDGE OF SLABALUM. S COLOR, G PAGNT E \ \ EDGE OF SLAM EDGE OF SIDEWALK BY LANDLORD ' ;4 " lSLM COLUMN j EDGE OFSID K BY LANDLORD _J i i LANDLORD'S BLDG._ NEUTRAL COLUMN AT \AX) `\ Al A! T nA2 A,2J LANDLORD'S TYP. E CONSTRUCTION TENANT STOREFRONT K'eI""""�N0F,TH ELEVATION A2J SCALE: 1/4' - I'-0' 8', 20 GA, M.S. * 16' OAC. {LATH 3/4' FR PLYWOOD CAP 4 2 X 8 TREATED WD. BAND BOARD • PERIMETER I X 8 BAND BOARD, PAINTIeD W/ 1 X 4 * TOP 3 /5/8', 20 GA. M.S. • 16' OCG. ill W/ 5/8' GYP. BD. EA SIDE, 2 X 4 LAY -IN CLG. PAINTEp • 8'-0' AFF. 3 DETAIL 6 WALL CAP �1_ SCALE: 1/2' = V-0' TENANT 2 1/2'M.S. 4 5/8'GY10. BD. ENCLOSURE --. ---. TENANT 31/2"A. 4 5/8'GYP. BD. WALL -BLDG. COLUMN -- TENANT 5/8'GYP. BD. WALL PLAN DETAIL AZJ SCALE: 1/2' - I'-0' I o,vt�crt�n�� I art vtVG ,w�IV GiLf+A7.7 �IWRVI�L DCLVW VINr'- CGJJC. I � I UJEST ELEVATION A2J SCALE: 1/4' = I'-0' E 2' X BLOCKING, AS REQUIRED CONTIN. 2' X 4' BLK'G LIGWT FIXTURE $Y E.G. BLK'G AS REQ'D 3 1/4' COLONIAL OGEE CROWN MOLD CCM 325), WOOD STAINED 1/4' BIRCH VENEER PLYWOOD (STAINED) OVER 1X FRAME (TYP.) -r WOOD CAP MOLD (MM 125). STAINED 8' 4 1/4' COLONIAL OGEE CROWN MOLD (CM 425), STAINED, PROVIDE BLOCKING AS REQ'D. NOTE: MOLDING: NUMBERS ARE FROM 'DAVIDSON LUMBER GO.' L I G H T TROFFER DETAIL AFP. Y 5/8' GYPSUM BOARD CEILING TENANT FUW PAINT -3 NIGHT DEPQ X 18 1/2'H FRS -PAINT-I LIGHT TROFFER SEE DETAIL 8/A2J TARGET LANDLORD'S TYP, BLOCK, (TS 1/16'x 3 ALUCOBOND PANEL 1/8'x 31/8") e - Planning - Interiors 118 W. St. Ph 317/42 air a k d mq)obs, lN46204 -4999 Fac: 3171423-4996 Emsil: TENANT'S 5'-0' X 8' - 31/2 5EADEr. CASING AFF. FABRIC AWNING W/ 6 OWNER: SERIF STYLE LETTEF (5'WIGNLETTERS • I II I INTERIOR ELEC. OPE Cud=® 'SIGN' BY TENANT SIDE USE 'n I (MIN V-0' BACK FRS STD. 2 1/4' ONIAL STOREFRONT) OPENING. FLUTTER CASING (C L - - - - - J L - _ - J INTERIOR APPLIED WOOD JAMBS / (BUSINESS WOURS 4 4AIR RAIL (CR 44I 0 z TENANT'S ALUM. ST( :r 9 SYSTEM, SEE SECTI V w a ►-a V Al LANDLORD'S TYP. kn CAST STONE PANEL 9 a�nNgn� ltrrrrprjrrr' s�`� �GISTFR� • .� 'y A '`�N.� � 3336 z s• STATE OF :° 8' WIGW ALUMINUM .11: .. BASE 4 SILL I 8' TENANT STOREFRONT K'eI""""�N0F,TH ELEVATION A2J SCALE: 1/4' - I'-0' 8', 20 GA, M.S. * 16' OAC. {LATH 3/4' FR PLYWOOD CAP 4 2 X 8 TREATED WD. BAND BOARD • PERIMETER I X 8 BAND BOARD, PAINTIeD W/ 1 X 4 * TOP 3 /5/8', 20 GA. M.S. • 16' OCG. ill W/ 5/8' GYP. BD. EA SIDE, 2 X 4 LAY -IN CLG. PAINTEp • 8'-0' AFF. 3 DETAIL 6 WALL CAP �1_ SCALE: 1/2' = V-0' TENANT 2 1/2'M.S. 4 5/8'GY10. BD. ENCLOSURE --. ---. TENANT 31/2"A. 4 5/8'GYP. BD. WALL -BLDG. COLUMN -- TENANT 5/8'GYP. BD. WALL PLAN DETAIL AZJ SCALE: 1/2' - I'-0' I o,vt�crt�n�� I art vtVG ,w�IV GiLf+A7.7 �IWRVI�L DCLVW VINr'- CGJJC. I � I UJEST ELEVATION A2J SCALE: 1/4' = I'-0' E 2' X BLOCKING, AS REQUIRED CONTIN. 2' X 4' BLK'G LIGWT FIXTURE $Y E.G. BLK'G AS REQ'D 3 1/4' COLONIAL OGEE CROWN MOLD CCM 325), WOOD STAINED 1/4' BIRCH VENEER PLYWOOD (STAINED) OVER 1X FRAME (TYP.) -r WOOD CAP MOLD (MM 125). STAINED 8' 4 1/4' COLONIAL OGEE CROWN MOLD (CM 425), STAINED, PROVIDE BLOCKING AS REQ'D. NOTE: MOLDING: NUMBERS ARE FROM 'DAVIDSON LUMBER GO.' L I G H T TROFFER DETAIL AFP. Y 5/8' GYPSUM BOARD CEILING TENANT FUW PAINT -3 NIGHT DEPQ X 18 1/2'H FRS -PAINT-I LIGHT TROFFER SEE DETAIL 8/A2J GYP. BRD. 4' COLONIAL BASE CPG 425), STAINED CFT-I NOTE.• MOLDING NUMBERS ARE F?ROf-I "DAVIDSON LUMBER CO.' WALL SECTION Is L IGlI4T TROFFER NEW 4' CONCRETE SLAB ON - GRADE, REINF. w/6x6-WI.4xWIA W.W.F. ON 6 MIL. VAPOR BARRIER OVER 4' (MIN.) OF COMPACTED 53 STONE. EXISTING CONCRETE FLOOR SLAB 3 1/4' BEADED CASING STD. 2 1/4' COLONIAL (C 350) CUSTOMER SERV. CASING (C 356) SIDE STM RM. SIDE t::- FLUTTED JAMB 4 HEAD EXISTING 8' CAST -IN-PLACE CONCRETE WALL wA4 RE -BAR • +/.8' OL. EXIST. re__� DOOR C A 5 (NG AJOIO FLOOR SLAB • JOIONING SPACE A2.1 1 1/2" = 1'-0' DUALL. SECTION Tho 'a DEPOSITORY AA2.1 I"=1t-01 2 SECTION �2_NTS -6' +/- I'OR TO LIGHT VALANCE • PERIMETER 3 1/8'X3 1/8' TARGET C BLOCK, (TS 1/16'x 3 Aprz. IV 1/8'x 31/8") e - Planning - Interiors 118 W. St. Ph 317/42 air a k d mq)obs, lN46204 -4999 Fac: 3171423-4996 Emsil: 2 1/2' CHAIR FAIL (CR 44), STAINED 31/2 5EADEr. CASING AFF. (C 350) OWNER: -----PAINT-1 GYP. BRD. 4' COLONIAL BASE CPG 425), STAINED CFT-I NOTE.• MOLDING NUMBERS ARE F?ROf-I "DAVIDSON LUMBER CO.' WALL SECTION Is L IGlI4T TROFFER NEW 4' CONCRETE SLAB ON - GRADE, REINF. w/6x6-WI.4xWIA W.W.F. ON 6 MIL. VAPOR BARRIER OVER 4' (MIN.) OF COMPACTED 53 STONE. EXISTING CONCRETE FLOOR SLAB 3 1/4' BEADED CASING STD. 2 1/4' COLONIAL (C 350) CUSTOMER SERV. CASING (C 356) SIDE STM RM. SIDE t::- FLUTTED JAMB 4 HEAD EXISTING 8' CAST -IN-PLACE CONCRETE WALL wA4 RE -BAR • +/.8' OL. EXIST. re__� DOOR C A 5 (NG AJOIO FLOOR SLAB • JOIONING SPACE A2.1 1 1/2" = 1'-0' DUALL. SECTION Tho 'a DEPOSITORY AA2.1 I"=1t-01 2 SECTION �2_NTS -6' +/- I'OR TO LIGHT VALANCE • PERIMETER 3 1/8'X3 1/8' TARGET C BLOCK, (TS 1/16'x 3 . RAPP Associates, LLC 1/8'x 31/8") e - Planning - Interiors 118 W. St. Ph 317/42 air a k d mq)obs, lN46204 -4999 Fac: 3171423-4996 Emsil: CwrvpasaodawS@aol.com 31/2 5EADEr. CASING 2040SAM (C 350) OWNER: NAME %AMC CLLR M ON STORAGE SIDE USE CASED WOOD STD. 2 1/4' ONIAL OPENING. FLUTTER CASING (C ). WOOD JAMBS 2 I/2' 4AIR RAIL (CR 44I 0 _ 4' COLONIA4 BASE CPG 425) I INTERIOR ELEVATION A2.I NTS r I 9 I RCHITECT C RA CRAIG . RAPP Associates, LLC Architect e - Planning - Interiors 118 W. St. Ph 317/42 air a k d mq)obs, lN46204 -4999 Fac: 3171423-4996 Emsil: CwrvpasaodawS@aol.com PROJECT NUMBER 2040SAM OWNER: NAME %AMC CLLR M w H w 0 w V w a ►-a V C kn kn a�nNgn� ltrrrrprjrrr' s�`� �GISTFR� • .� 'y A '`�N.� � 3336 z s• STATE OF :° .11: .. CERfkICAMbN D7 ,OILS ELEVATI 4 SECTIONS Mai" WAS AS ED °A' 16/04 /04 onruwrn ` CwR 2.1 r I 9 I HVAC FLOOR PLAN SCAM 1/4' = V-0' ARCHITE T Cw CRAIG W. RAPP Associates, Architecture - Plann' LLC g - Interiors 118 W. St. Clair St. Indiso Ph: 317/4234999 Fm: Email: cwrapp apolis, IN 46204 317/423-4996 ciates@aol.com PROJECT ER 204V5,00 OWNER: NAM CL4= CLU NM W � 1 W� Z W W� W � L 0 kn r l veII1L►IIHi No. -* PE10100 76 *_ STATE OF NALE mn� CIIiTTF1CA710 AFR�T DQlgtlr?Ipi PLAN HVAC 0111111valk. .CACI AS NOTED comm mn JTL amomm m. JW❑ ws Ml. r I I /. 0 I I NOTE: (E,C, MAKE ALL CONN, AFTER OWNER'S EQUIP, IN PLACE) GENERAL NOTES: ALL WORK TO BE DONE IN ACCORDANCE WITH LOCAL ,AND NATIONAL ELECTRICAL CODES. LIGHT FIXTURE SCHEDULE MARK DESCRIPTION A 2x2 LAY IN BATH B RECESSED CANS (LOBBY) C 4' STRIPS IN BACK AREA (2 LAMP) D CEILING HUNG LIGHTS E EXIT LIGHT F (5) 4', (6) 3', (2) 2', (1) 18' STRIPS (VALANCE) (MISC SIZES TO MAKE CONTINUOUS) 'l,ectricaI pl, it-J[N SCALE: 1/2" 2l1/480 VOLT 100 AMP MAIN BREAKER PANEL 3 PHASE PANE 120/208 VOLT BY LANDLORD 3 PHASE I" C 24 CIRCUIT WITH 4 O6 60 AMP / N GROUND PER NEG - 30 KvA BY TENANT TRANSFORMER GROUND PER NEC RISER DIAGRAM 1 I/4 lUltl-I 4 "2 PANEL ;II=ORI" IE R Vav 3 24 CIRCUIT Nc. 10200 95j STA OF ELECTRIC L CONTRACTOR: ELGENCO, INC. (31 7) 32 — 1 090 ISSUE DATES & REVISIONS: 7/30/0 E-1 SHEET NO. a a I 0 I r I