HomeMy WebLinkAboutG0.0 Cover SheetSPACE F30A - LANDLORD IMPROVEMENTS PROJECT OWNER ARCHITECT CONTRACTOR PROJECT TEAM red architecture + planning 855 Grandview Ave, Suite 295 Columbus, Ohio 43215 P: 614.487.8770 F: 614.487.8777 CONTACT: Stephan Sahayda PROJECT INFORMATION PROJECT DESCRIPTION SHELL BUILDING CODE SUMMARY SEPARATION: N/A IBC SECTION 508.3.3 FIRE SUPPRESSION: FULLY SPRINKLERED IBC SECTION 903 USE GROUPS: M MERCANTILE IBC SECTION 304 CONSTRUCTION TYPE: LENGTH OF TRAVEL: GENERAL CONSTRUCTION NOTES 1. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCES. 2. THE SLOPE OF PUBLIC WALKS SHALL NOT EXCEED MAX. CROSS SLOPE 2 %. 3. WALKING SURFACES SLOPING GREATER THAN 2 % SHALL BE SLIP RESISTANT. 4. PROVIDE A 60" x 60" MIN. LANDING ON STRIKE SIDE OF DOOR WITH 44" MINIMUM WIDTH IN DIRECTION OF TRAVEL. 5. WALKS SHALL EXTEND 24" TO THE SIDE OF THE STRIKE EDGE OF DOOR OR GATE T HAT SWINGS TOWARD THE WALK. 6. EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THAN 3'-0" WIDE BY 6'-8" HIGH CAPABLE OF OPENING 90 DEGREES AND MOUNTED SO THAT THE CLEAR WIDTH OF THE EXIT SHALL BE A MINIMUM OF 32". 7. THRESHOLDS TO BE A MAXIMUM OF 1 2"ABOVE THE ADJACENT FINISHED FLOOR. 8. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS FOR INTERIOR DOORS AND 15 LBS FOR EXTERIOR DOORS. 9. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC SLIDERS SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE. 10. THE BUILDING SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIIDELINES (ADAAG) AND ANSI A117.1-2009, INCLUDING BUT NOT LIMITED T0 IBC CHAPTER 11. 11. CONTROLS AND OPERATING MECHANISMS SHALL BE ACCESSIBLE AND HAVE MOUNTING HEIGHTS COMPLYING WITH ANSI 4.27. 12. ALL ROOM, DIRECTIONAL, AND INFORMATION SIGNS SHALL BE ACCESSIBLE DESIGN COMPLYING WITH ANSI 4.13 AND 4.30. ACCESSIBILITY INFORMATION SITE LOCATION MAP 1. THE USE OF THESE DOCUMENTS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. REUSE OR REPRODUCTION OF THE DOCUMENTS, (WHOLE OR IN PART) FOR ANY OTHER PURPOSE IS PROHIBITED. RED ARCHITECTURE + PLANNING RETAINS ALL RIGHTS OF OWNERSHIP. 2. THE A.I.A. DOCUMENT A201-2007, GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, SHALL APPLY TO THE PROJECT. A COPY OF THE GENERAL CONDITIONS IS AVAILABLE AT THE OFFICES OF RED ARCHITECTURE + PLANNING. 3. THE CONTRACTOR AND SUB-CONTRACTORS SHALL BE SOLELY RESPONSIBLE FOR COMPLYING WITH ALL FEDERAL, STATE, AND LOCAL SAFETY REQUIREMENTS TOGETHER WITH EXERCISING PRECAUTIONS AT ALL TIMES FOR THE PROTECTION OF PERSONS INCLUDING EMPLOYEES AND PROPERTY. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SUB-CONTRACTORS TO INITIATE, MAINTAIN, AND SUPERVISE ALL SAFETY REQUIREMENTS, PRECAUTIONS, AND PROGRAMS IN CONNECTION WITH THE WORK. 4. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL WORK AND FOR THE MEANS, METHODS, PROCEDURES, TECHNIQUES, AND SEQUENCE OF CONSTRUCTION. 5. GENERAL CONTRACTOR SHALL PROVIDE ALL REQUIRED PERMITS, FEES, AND INSPECTIONS AS MAY BE REQUIRED BY GOVERNING BODIES HAVING LEGAL JURISDICTION. 6. THE GENERAL CONTRACTOR IS TO GUARANTEE ALL WORK INCLUDING WORK DONE BY SUB-CONTRACTORS FOR A PERIOD OF A MINIMUM ONE (1) YEAR COMMENCING WITH THE DATE OF SUBSTANTIAL COMPLETION OF THE WORK, OR AS STATED IN CONTRACT WITH OWNER. WHICHEVER IS GREATER. 7. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SCHEDULING AND MONITORING OF ON-SITE TESTING AND INSPECTION SERVICES AS LISTED IN THE PROJECT MANUAL AND GENERAL CONDITIONS A201. 8. WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS EITHER IN CONTRACT OR NOT IN CONTRACT HE SHALL BE RESPONSIBLE FOR LOSS AND/ OR DAMAGE TO THESE ITEMS. 9. GENERAL CONTRACTOR TO HAVE JOB PHONE ON PREMISES DURING ENTIRE CONSTRUCTION PERIOD. 10. THE GENERAL CONTRACTOR & EACH SUBCONTRACTOR IS TO HAVE A FULL TIME QUALIFIED SUPERVISOR ON THE SITE AT ALL TIMES WHILE WORK IS BEING PERFORMED. 11. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF THE WORK ALL EXITS, EXIT LIGHTING, FIRE PROTECTION DEVICES, AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 12. THE GENERAL CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND EXISTING FIELD CONDITIONS WITH THE DRAWINGS. IN PARTICULAR: OVERALL WALL DIMENSIONS, SOIL CONDITIONS, INCOMING UTILITIES, ETC. GENERAL CONTRACTOR IS TO REPORT IMMEDIATELY TO THE ARCHITECT ANY VARIANCES OR FIELD CONDITIONS THAT MAY CAUSE CONSTRUCTION PROBLEMS PRIOR TO COMMENCING WORK. 13. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. ALL PARTITION LOCATIONS, ALL DOOR AND OPENING LOCATIONS SHALL BE SHOWN ON FLOOR PLAN. IN CASE OF CONFLICT NOTIFY THE ARCHITECT. FLOOR PLAN BY ARCHITECT SUPERSEDES ALL OTHER PLANS. ALL DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES INCLUDING CARPET, PAD, CERAMIC TILE, V.C.T., SLATWALL, ETC. 14. ALL DIMENSIONS SHOWN ARE TO FACE OF MASONRY (BLOCK OR BRICK) OR FRAMING UNLESS SPECIFICALLY NOTED OTHERWISE. 15. ALL DIMENSIONS ON ARCHITECTURAL DRAWINGS LOCATING STRUCTURAL ELEMENTS ARE TO CENTERLINE OF STEEL COLUMNS AND STEEL BEAMS UNLESS NOTED OTHERWISE. 16. ALL DIMENSIONS SHOWN ARE NOMINAL DIMENSIONS UNLESS SPECIFICALLY NOTED OTHERWISE. 17. EGRESS DOORS SHALL BE PROVIDED PER IBC SECTIONS 1014 THROUGH 1024. 18. ALL DOOR HANDLES SHALL BE OF THE LEVER TYPE, HARDWARE SHALL BE MOUNTED NO HIGHER THAN 48" ABOVE FINISH FLOOR. 19. ALL ACCESS PANELS SHALL BE 24"X30" UNLESS OTHERWISE NOTED. 20. ALL GLASS UNITS LOCATED IN HAZARDOUS LOCATIONS AS INDICATED IN IBC 2406.3 SHALL COMPLY WITH TEST REQUIREMENTS OF CONSUMER PRODUCT SAFETY COMMISSION 16, CFR PART 1201 FOR HUMAN IMPACT LOADS. 21. ALL SAW CUTTING AND CORING LOCATIONS SHALL BE REVIEWED IN FIELD BY THE GENERAL CONTRACTOR PRIOR TO CUTTING/CORING. 22. ALL WOOD IS TO BE FIRE-RETARDANT TREATED PER AWPA C20 AND C27 AND SHALL NOT HAVE A FLAME SPREAD OF GREATER THAN 25 WHEN TESTED IN ACCORDANCE WITH ASTM E-84. PER IBC SECTION 2303.2. 23. ALL EXTERIOR WOOD BLOCKING IS TO BE PRESSURE TREATED PER AWPA U1 AND M4. 24. ALL FASTENERS, CONNECTORS, OR OTHER HARDWARE IN DIRECT CONTACT WITH PRESERVATIVE TREATED OR FIRE RETARDANT TREATED WOOD SHALL BE STAINLESS STEEL TYPE 304 OR TYPE 316, OR HOT-DIPPED GALVANIZED STEEL ASTM A653, CLASS G-185 WITH 1.85 OUNCES OF ZINC PER SQUARE FOOT TO REDUCE THE CORROSION PROCESS . 25. FIREBLOCKING SHALL BE INSTALLED IN CONCEALED SPACES OF STUD WALL AND PARTITIONS, INCLUDING FURRED OR STUDDED-OFF SPACES OF MASONRY OR CONCRETE WALLS, AND AT THE CEILING AND FLOOR OR ROOF LEVELS. PER IBC SECTION 717.2.2. 26. FIREBLOCKING SHALL BE INSTALLED AT ALL INTERCONNECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS OVER CABINETS, DROP CEILINGS, COVE CEILINGS AND SIMILAR LOCATIONS. PER IBC SECTION 717.2.3. 27. REQUIRED FLAME SPREAD RATING: INTERIOR FINISH OF WALLS AND CEILINGS SHALL HAVE A FLAME SPREAD RATING NOT GREATER THAN THAT DESIGNATED BY THE CLASS PRESCRIBED FOR THE VARIOUS GROUPS LISTED IN IBC TABLE 803.5, WHEN TESTED IN ACCORDANCE WITH IBC SECTION 803.2. 28. PROVIDE PORTABLE FIRE EXTINGUISHERS WITH U.L. LABEL AND A RATING OF NOT LESS THAN 4A 80B:C WITH 75 FT TRAVEL DISTANCE TO ALL POSITIONS OF BUILDING OR AS DIRECTED BY THE FIRE DEPARTMENT FIELD INSPECTOR. BUILDING CODE INFORMATION LIST OF DRAWINGS COVER SHEET REVISION FEB 10, 2017 PRELIMINARY PERMIT/BID DRAWING HAS BEEN ISSUED OR REVISED DRAWING HAS BEEN RE-ISSUED WITH NO REVISIONS GENERAL G0.0 COVER SHEET G0.1 ADAAG / ANSI DETAILS G0.2 ADAAG / ANSI DETAILS G0.3 LIFE SAFETY PLAN ARCHITECTURAL A1.1 ARCHITECTURAL FLOOR PLAN AND REFLECTED CEILING PLAN A1.2 ENLARGED RESTROOM PLANS AND ELEVATIONS A8.1 DOOR HARDWARE, SCHEDULE, AND NOTES FIRE PROTECTION FP.1 FLOOR PLAN FIRE PROTECTION MECHANICAL DRAWINGS M1.1 MECHANICAL AND PLUMBING PLAN M2.1 MECHANICAL AND PLUMBING SCHEDULES AND DETAILS M3.1 SPECIFICATIONS PLUMBING M3.2 SPECIFICATIONS MECHANICAL M3.3 SPECIFICATIONS MECHANICAL ELECTRICAL DRAWINGS E1.1 ELECTRICAL PLAN E7.1 SPECIFICATIONS ELECTRICAL THIS PROJECT CONSISTS OF LANDLORD'S IMPROVEMENTS TO AN EXISTING 743 SQ FT INTERIOR TENANT SPACE WITHIN AN OUTDOOR MALL BUILDING. LANDLORD'S WORK INCLUDES THE CONSTRUCTION OF A NEW RESTROOM, ADDITION OF A JANITORS SINK, AND MECHANICAL, ELECTRICAL, AND PLUMBING WORK. NO EXTERIOR WORK IS TO BE PERFORMED. ANY MODIFICATIONS TO SPRINKLER SYSTEM/ FIRE ALARM SYSTEM SHALL BE PERFORMED BY A LICENSED SPRINKLER/ FIRE ALARM CONTRACTOR UNDER A SEPARATE PERMIT AT DISCRETION OF A LICENSED CONTRACTOR. NO CHANGE TO USE, OCCUPANCY OR EGRESS PROJECT LOCATION MEP ENGINEER red architecture + planning 855 Grandview Ave, Suite 295 Columbus, Ohio 43215 P: 614.487.8770 F: 614.487.8777 CONTACT: Doug Smelker TBD IBC SECTION 602 IBC SECTION 1016.1 II-B, UNPROTECTED M 250' KEY LOCATION PLAN 14390 CLAY TERRACE BLVD re d CARMEL, INDIANA 46032 WPG007 SPACE F30A - LANDLORD IMPROVEMENTS PROJECT NUMBER: SHEET: FOR WASHINGTON PRIME GROUP 180 EAST BROAD STREET, COLUMBUS, OH 43215 ISSUE DATE PERMIT FEB. 01, 2018 COPYRIGHT 2018. ALL DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE PROPERTY OF RED ARCHITECTURE + PLANNING LLC AND MAY NOT BE USED, DUPLICATED OR ALTERED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. G0.0 2/1/2018 8:05 AM AREA OF WORK BUILDING CODE 2014 INDIANA BUILDING CODE PLUMBING CODE 2012 INDIANA PLUMBING CODE MECHANICAL CODE 2014 INDIANA MECHANICAL CODE ELECTRICAL CODE 2008 NATIONAL ELECTRIC CODE LIFE SAFETY CODE 2014 INDIANA FIRE CODE ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE GAS CODE 2014 INDIANA FUEL GAS CODE ACCESSIBILITY CODE ANSI A117.1-2009 AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) 2010 USE AREA S.F. / PERSON OCCUPANT LOAD IBC TABLE 1004.1.1 EGRESS REQUIRED O.L. X .20" = IBC 1005.1 EXITS REQUIRED IBC TABLE 1021.1 EXITS PROVIDED EGRESS WIDTH PROVIDED 36" FIRE SUPPRESSION: CONSTRUCTION TYPE: LENGTH OF TRAVEL: OCCUPANT LOAD: IIB, UNPROTECTED M 250' USE GROUPS: FULLY SPRINKLERED PLUMBING FIXTURES PROVIDED: IBC SECTION 903 IBC SECTION 309 IBC SECTION 602 IBC TABLE 1016.1 IBC TABLE 1004.1 M MERCANTILE IBC TABLE 2902.1 M USE GROUP SPACE F30A 743 SQ. FT. 30 25 36" 1 1 TENANT SPACE CODE SUMMARY Washington Prime Group 180 East Broad Street Columbus, Ohio 43215 P: 614.887.5664 CONTACT: Chad Biniker WATER CLOSET/URINALS MALE/FEMALE LAVAT0RIES NUMBER OF FIXTURES PROVIDED 1 1 REQUIRED NUMBER OF FIXTURES .25/.25 .15/.15 OCCUPANT LOAD M 25 1:50 .25/.25 1:80 .15/.15 USE OCC. MALE/FEMALE MS 1 1 1 CALC. CALC. EGRESS: REQ'D PROVIDED EGRESS WIDTH (OCC LOAD x .2") = 25 x .2" = 5" 36" IBC SECTION 1005.1 NUMBER OF EXITS: 1 1 IBC SECTION 1021.2 EXIT ACCESS TRAVEL DISTANCE: 250'-0" 35'-11" IBC TABLE 1016.1 COMMON PATH OF TRAVEL: 75'-0" 11'-6" IBC SECTION 1014.3 FEB 01, 2018 04/30/18 Nick Mishler