Loading...
HomeMy WebLinkAbout04090073 Building PlansARCHITECT: jr4a CSO INTERIORS 280 E. PARKWOOD SUITE 200 INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (317) 574.0957 FAX Mal 6' - & CONTRACTOR: Du VAWke REALTY CORPORATION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX OF DRAWINGS • COVER • A201 DEMOLITION & CONSTRUCTION PLAN • A202 REFLECTED CEILING & ELECTRICAL PLAN • A801 FINISH PLAN & ELEVATIONS El APPROVED AS 511BMIfn E] APPROVED M N018 EIREJECTED SMTM DATE CWMY KEYPLAN SCALE: NOT TO SCALE NORTH SPH ERION ATLANTIC WORKFORCE, FIVE PARKWOOD SPECIFICATIONS AND GENERAL NOTES 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1 1.1 1.2 1.3 1.4 1.5 1.6 CONTRACT CONDITIONS THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION, INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. GENERAL REQUIREMENTS WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE, WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. THE CONTRACTOR SHALL COORDINATE 0 RDINAIE AND SCHEDULE WORK 8Y OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND "FURNISHED AND/OR INSTALLED" ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6" X 6" ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6" X 6" ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9" X 9" DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING, THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. SUITE 125 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. 2 DEMOLITION 2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE EXTENT OF WORK, PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW WORK. 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL BE INCLUDED. 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE DRAWINGS. 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES. 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR NOTED TO BE REPAIRED. 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK IN SCOPE OF CONTRACT. 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE -- OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO DEMOLITION OPERATIONS, UTILITY SERVICE SHALL BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET. 2.11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. 5 METAL FABRICATIONS 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS REQUIRED TO COMPLETE WORK. 6 WOOD AND PLASTIC 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE CONTENT. 6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32". 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI STANDARDS. .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR TO FABRICATION OF MULTIPLE UNITS. 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACES. .2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS. 6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4008 FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL THICKNESS). .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. .3 CABINET HARDWARE SCHEDULE: .1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES" BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL. INDIANAPOLIS, IN 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY OPERATING FOR TEN DAYS. 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM WIDTH NOT TO EXCEED 1/8 U.O.N. 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL OUTLETS. 7 JOINT SEALERS 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS AND FIXTURES: .1 "DOW CORNING 786"; DOW CORNING CORP. .2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. .3 "863 #345 WHITE"; PECORA CORP. .4 "PROGLAZE WHITE"; TREMCO CORP. .5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING SURFACES: .1 "CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. .2 "AC -20"; PECORA CORP. .3 "SONOLAC"; SONNEBORN BUILDING PRODUCTS .4 "TREMCO ACRYLIC LATEX 834"; TREMCO, INC. 8 DOORS AND WINDOWS 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH, 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH AND LOCKSETS, 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. 9 FINISHES 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. .1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING AT CEILING. USE PREFORMED OUTSIDE CORNERS. 9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE "X" TAPERED EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA - 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD. 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM DAMAGED OR SOILED TILES. .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN. .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS UNLESS NOTED OTHERWISE. 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CASED OPENING UNLESS NOTED OTHERWISE. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH CARPET. 9.6 RESILIENT FLOORING: .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. .2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. 9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM SURFACE VARIATION OF X" IN 10 FEET, NON -CUMULATIVE. 9.8 CARPEL: INSTALL CARPETING WHICH MEETS THE FOLLOWING STANDARDS: FLAMMABILITY: ASTM 2859 SURFACE BURNING: ASTM E84 SMOKE DENSITY: ASTM E662 SOUND ABSORPTION: ASTM C423 FADE RESISTANCE: AATCC 16E STATIC RESISTANCE: AATCC 134 WARRANTY: 10 YEARS .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, REINSTALL SUCH ITEMS. .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOR THE VARIOUS SUBSTRATES, AS INDICATED. 1. FERROUS METAL: A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL 2. NON-FERROUS METAL: A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC SEMI -GLOSS FINISH 3. FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING 4. NON-FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING. 8. WOOD: A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL B. STAIN -VARNISH RUBBED FINISH: 1. FILLER: 1 COAT 14800 WONDER WOODSTAIN PASTE WOOD FILLER (OPEN GRAIN WOODS). 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN ALKYD STAIN. 3. SEALER: 1 COAT #4900 WONDER WOODSEALER QUICK DRY SEALER. 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN ALKYD SATIN VARNISH. 10. GYPSUM WALLBOARD: A. ACRYLIC LATEX SATIN ENAMEL FINISH: 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC LATEX SATIN ENAMEL 13. PRECAST CONCRETE: A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC LATEX HOUSE PAINT PRIMER. 2. FINISH: 1 COAT #44101 DEV -VO -TD( LAID( TEXTURE COATING. 9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLE AN AND WITHOUT WRINKLES, GAPS OR OVERLAPS. .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT ACCEPTABLE. .2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6" FROM OUTSIDE CORNERS. 10 SPECIALTIES 10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, SEMI RECESSED, DUO -PANEL, FIELD PAINTED. LLC c11HSNM01 A -M / 13MM A0 x,10 S301nPJ3S AIINfIImoo :101d3a Sapo; j powtf Pie 0181S 110 t.0091n6AaU 11E Ljom aoue!jdwoo o4 joe(gnS ;UI1;i.SN0�11#��t3S'b3'#3 ', y 12.1 CASEWORK: .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: .1 IMPERIAL CABINET CO., INC. .2 MERILLAT INDUSTRIES, INC. .3 YORKTOWNE CABINETS 15/16 MECHANICAL AND ELECTRICAL 15/16.1 MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND ELECTRICAL SYSTEMS. 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF DESIGN/BUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, AND PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A CERTIFIED ENGINEER. 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK, 15/16.4 SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL COORDINATE WITH OTHER CEILING COMPONENTS. 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OWNER'S AGENT. 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE EQUIPML:NT/APPLIANCE FOR WHICH IT WAS DESIGNATED. VERIFY EQUIPMEM MOUNTING REQUIREMENTS FOR SCHEDULED EQUIPMENT. 15/16.7 SWITCHES SHALL 13E GANGED UNDER ONE PLATE. DIMMERS SHALL BE GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE INSTALLATION SHALL OCCUR, 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF OUTLETS, UNLESS OTHERWISE NOTED, 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE IVORY. 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL PROVIDING PROPER ACCESS TO RECEPTACLES. 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL FOR SPECIFIC LOCATION. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT OF `ROUGH -IN" CONSTRUCTION. GN GENERAL NOTES GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: A. TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. C. TO TOP OF FINISHED FLOORS. D. TO BOTTOM OF FINISHED CEILINGS. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, EXISTING CONSTRUCTION AND WALL TYPES. GN.4 TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED OTHERWISE. GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS OBSERVATION. GN] FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0" NON- CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS. GN.9 SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED TO STUD FRAMING, AT THESE PARTITIONS, BACK TO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY TENANT. CITY OF CARMEL/CLAY TOWNSHIP Dept. of Community Services - Building & Code Enforcement One Civic Square 1" Floor; Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT As the authorized agent responsible for obtaining a permit or permits', I certify that these plans are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building Services. I also understand that if it is determi: d that these plans are not identical, a STOP WORK ORDER will be served, as required u ir the Ordinances referenced below. Authorized Signature Printed Name 'Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 L and Section 29.4.3 entitled "Administration". Required Uy Carmel / Clay Township Zoning Ordinance, Section 31.1 entitled "Violations and Penalties". S:Permits/Forms/AuthentStickerll-OI -�� / F -OV J ` wQ U_ O W O LO �No z0� Q 1 LO Jai Z zZ� oQ =0 ;�Rt1Q910Q3& >' t �ST�CTf �F f= $ inoao °°��, 08/18/04 CSO #24200 ci DEMOLITION PLAN SCALE: 1 /8"=1'-0" NORTH CONSTRUCTION PLAN SCALE: 1/8"= i I -oft NORTH DEMOLITION LEGEND: EXISTING DUPLEX WALL OUTLET TO BE DEMOLISHED EXISTING QUADRAPLEX WALL OUTLET TO BE DEMOLISHED ,`D EXISTING DEDICATED CIRCUIT OUTLET TO BE DEMOLISHED EXISTING PHONE/DATA WALL OUTLET TO BE DEMOLISHED WALL LEGEND: NOTES: _ — = EXISTING CONSTRUCTION TO BE REMOVED EXISTING PARTITION TO REMAIN NEW WALL PARTITION NOTE: ALL WALLS TO BE W1 UNLESS OTHERWISE NOTED, W1 2-1/2" 25 GAUGE METAL STUDS @24"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK o NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE GENERAL CONSTRUCTION NOTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER- DO NOT SCALE DRAWINGS. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. E. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. F. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. G. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. H. ALL WALLS SHALL BE CHAULKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION I. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS J. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARTION FOR NEW FINISHES. K. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. L. BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBUNDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION. M. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. LIFSAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. N. EXISTING DOORS AND DOOR FRAMES TO BE REUSED DURING CONSTRUCTION DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION. 0. ALL NEW WORKSURFACES TO RECIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT GENERAL DEMOLITION NOTES: A. DEMOLISH EXISTING WALLS THAT ARE SHOWN DASHED, BACK TO A POINT WHEREAS A SMOOTH SURFACE REMAINS FOR INSTALLATION OF NEW FINISHES. B. REMOVE ELECTRICAL AND DEVICE LINES IN WALLS THAT ARE SHOWN DASHED INCLUDING ALL ATTACHED WIRING. DEMOLISH ELECTRICAL DEVICES AND WIRING BACK TO A POINT WHEREAS PROPER PREPARATION FOR NEW FINISHES IS POSSIBLE. SEE ELECTRICAL AND FINISH PLANS FOR MORE INFORMATION. C. REMOVE ALL WALLS, MILLWORK, DOORS, AND DOOR FRAMES AS SHOWN DASHED. RESERVE DOORS AND DOOR FRAMES FOR RE -USE IN NEW PROJECT SCOPE. D. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH SHEET, A801, TO COORDINATE LOCATIONS OF NEW FINISHES E. REMOVE ALL EXISTING FLOOR OUTLETS SHOWN. PROVIDE AN EVEN FLOOR SURFACE IN PREPARATION FOR NEW FLOOR FINISH. F. ALL EXISTING BLINDS AT PERIMETER WINDOW LOCATIONS ARE TO BE CLEANED AND REPAIRED IF NECESSARY AT PROJECT COMPLETION. G. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNERS DIRECTION UNLESS OTHERWISE NOTED. DEMOLITION PLAN NOTES: REMOVED EXISTING DOOR/DOOR FRAME AND SAVE FOR REUSE. REMOVE EXISTING MILLWORK AND PLUMBING. CAP D2 PLUMBING AS NECESSARY. CONSTRUCTION PLAN NOTES: FP1 ALIGN FINISHED FACES. FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/A201. FP3 NEW OR RELOCATED RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. FP4 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER/REFRIGERATOR AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT. Fps COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL. FPs PROVIDE 18"X20" PAINTED PLYWOOD SHELF (25LBS. CAPACITY) TO BE INSTALLED BY G.C. COORDINATE W/ TENANT EXACT LOCATION AND MOUNTING HEIGHT. FP7 REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER 5 SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER Fpg G.C. TO INSTALL TENANT PROVIDED DISHWASHER. G.C. TO CONFIRM UNIT IS IN WORKING ORDER AND IS NOT LEAKING BEFORE TURNING UNIT OVER TO TENANT. Fps PROVIDE 5/8" x 4' x 8' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD. PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH TYPICAL WALL TYPE TYPICAL AT ALL EXTERIOR WALLS- 5/8" TYPE X G.W.B. FINISH BELOW EXISTING WINDOW SILL COVER METAL STU D PREFINISHED ALUMINUM RECEIVER TRIM "GB350". FASTEN AT WINDOW SILL & SET IN A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. TRIM COLOR TO MATCH BLDG. WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT WINDOW MULLION (`_1� DETAIL �,G,ENis DOOR SCHEDULE CSO Architecture DOOR Interiors FRAME Land Surveying HARDWARE REMARKS SIZELLJ w cn 0 w U I o C) N r Z �O mm Z W M z Q z O Q z O � ��o �p0 z m � _ _ va- ¢ ~ N Q 0O(l o0 nL ;o v � CD Q D-1 � W J a :2 __j F-- 1 w II II II 11 II cn__jm JViC1.UD Z O 100 RECEPTION 2@3'-0'8'-0" w 1 3/4" WD/GL D2 WD D2 L,S,CL,DB Q O Lo z 3 N 101 CONFERENCE 3'-0" 8'-0" 1 3/4" WOOD D4 HM D4 PS,S ~ Z 102 STORAGE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 L,S O 103 TELECOM 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 L,S SEE NOTE #5 104 BREAKROOM 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 105 OPEN OFFICE 3'-0" 8'-0" 1 3/4" WD/GL D1 HM D1 PS,S % "lilt 106 COPY/FAX 3'-0" 8'-0" 1 3/4-1 WOOD D1 HM D1 PS,S 107 INTERVIEW 3'-0" 8'-0" 1 3/4" WOOD D3 HM D3 PS,S 108 OFFICE/INTER. 3'-0" 8'-0" 1 3/4" WOOD D3 HM D3 PS,S DOOR SCHEDULE NOTES 1. ALL DOUKS ARE TO BE BLDG. STD. ALL DOOR FRAMES TO BE PAINTED P1. 2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD WHERE NEEDED. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. COORDINATE KEYING LOCKSETS WITH TENANT. 5. TELECOM 103 DOOR TO BE LOUVERED. w ON '_n" 1'-0" D3 TIMELY FRAME HARDWARE TIMELY FRAME 1/4" CLEAR TEMPERED GLASS SIDELIGHT. HARDWARE ZI n)1 T1 ,It t- _ CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @Copyright 2001 w cn 0 w U I o C) Co r Z �O mm m0 ai' U CD r � N ^ O 3 Q)� U L V) w� U o� J ~ N Z v 00 a � J a O LL Z O use ry 0 w o z o 00 '� w Q O Lo z 3 N N m CO) V DOOR/FRAME ELEVATIONS SCALE: 1/411=11-0" SII 1 /2"HW, 1 /2 "CW, & 1-1/4"V CONNECT TO BUILDING MAINS 2"W TO BUILDING DRAIN PLUMBING (*`�2 ISOMETRIC �01 SCALE: NTS U2 -n" )'-n', D4 .._�WOOD FRAME -1/4" TEMPERED GLASS INSET LEVER HARDWARE TIMELY FRAME ,,1/4" CLEAR TEMPERED GLASS SIDELIGHT. LEVER HARDWARE Duke REALT1f cottPow►noN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @Copyright 2001 w cn 0 w U I o C) Co r N NLli �O mm m0 ai' U CD r � N ^ O 3 Q)� U L V) J w W Z v a � J a O LL Z O use Q w o z V 00 '� Q O Lo z 3 N N CO) V �W� Z _ J Q L- 0 ~ Z avQ v a z W Q ad _I >Z Z F.. U. - O a J Z O O 2 — W c W a CO Certified ts�ttoo � rUC sss % "lilt AMi1MIS ! 0 STATE OF �f/f0/4It D w e r. A201 Of Sheets Duke Job Number: A/E Job Number: 24200c REFLECTED CEILING PLAN SCALE: 1/8"=1 1-011 NORTH ELECTRICAL PLAN SCALE: 1/8"= i $—opt NORTH REFLECTED CEILING LEGEND: EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE, TO MATCH BUILDING STANDARD EXISTING CEILING MTD. EXIT LIGHT TO BE REMOVED AND SAVED FOR RE—USE. 1KCEILING MTD. EXIT LIGHT. DUAL—LITE 14:11 NEW BLDG. STD. WALL WASHER EXISTING 2 X 2 LAY—IN GRID SUSPENSION SYSTEM NL NIGHTLIGHT LOCATION ELECTRICAL LEGEND: SYMBOL DESCRIPTION Architecture DUPLEX WALL OUTLET Interiors QUADRAPLEX WALL OUTLET 8D DEDICATED CIRCUIT OUTLET 0 PHONE/DATA WALL OUTLET (BOX AND PULL STRING) (i) NEW FLOOR MOUNTED DUPLEX OUTLET ® NEW FLOOR MOUNTED PHONE/DATA OUTLET 6GFI GROUND FAULT INTERUPT CIRCUIT OUTLET +44 DENOTES HEIGHT A.F.F +66 DENOTES HEIGHT A.F.F N DENOTES NEW ELECTRICAL LOCATION GENERAL CEILING NOTES: A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING, E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFEiY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. F. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. G. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. H. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. I. CEILING HEIGHT IS 8'-6" A.F.F. UNLESS OTHERWISE NOTED. GENERAL ELECTRICAL NOTES: A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT AT PHONE AND DATA LOCATIO S AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. B. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIABLE WITH TENANT EQUIPMENT. D. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING RE UIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP FOR SYSTEMS BASE FEED AN[ OR POWER POLES. ELECTRICAL CONTRATOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH. F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED ® 18" A.F.F. UNLESS OTHERWISE NOTED. ELECTRICAL PLAN NOTES: E� PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. E2 CORE DRILL. LOCATIONS TO BE VERIFIED BY TENANT'S FURNITURE VENDOR. E3 PROVIDE (1 GROUND BAR IN TELECOM 103 WITH A SOLID 6" CABLE TO COLD WATER PIPE OR BLDG. GROUND. (1)#6 STRANDED TO THE TELEPHONE SYSTEM AND (1) #12 SOLID WIRE TO PATCH PANEL. G.C. TO VERIFY SPECIFICATIONS AND LOCATIONS W/ TENANT. E4 NEW DUPLEX OUTLET WITH DEDICATED CIRCUIT TO BE MOUNTED AT SHELF HEIGHT. VERIFY EXACT LOCATION AND HEIGHT W/ TENANT. Duke REALTY C0%VRAn0N 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @Copyright 2001 w I U Li U I o 0 M Q 00 O p N 0 T tu m� N o V= o O o U J ..I Z a w W -j V a CC J O a L v CC Q p Z V O O o W 0 Z J 3N W V hL cn 06 LitP _1 �- 0 :Da Z a �, z z aW Q-' LU J � 0 �' Z LL - (� a o W Z O w c1c J LL W LU Z a 0 Certif' Toe" s i o_ 100361 r STATE OF m �N ANP •` ���� Iff0190N Drawing Number: A202 Of Sheets Duke Job Number: A/E Job Number: 24200C FINISH PLAN SCALE: 1/810= 1 1-0" Q2'-0' 3'-3' 2'-0' 2'-6' 2'-0' E �s1,-Ick, I i I I I � I I I I I I I l 1 CARPET - DIRECT GLUE c1 MFG: PATCRAFT J -4 ko PATTERN: SOUND INVESTMENT Corporate Office COLOR: ESTATE PLANNING vcT1 VINYL COMPOSITION TILE I w MFG: CONGOLEUM I C O O \ PATTERN: CHOICES BASE COLOR: CH17 ANTIQUE WHITE 61 VINYL BASE -4" COVE BASE m- � MANUFACTURER: JOHNSONITE 0 ' W C COLOR: 45 SANDALWOOD / / s V J i 1/4" CLEAR TEMPERED GLASS IN BLDG. STD. FRAME w W cc SINGLE BOWL STAINLESS P STEEL SINK WITH 36 GOOSENECK FAUCET. AN F DISHWASHER '; LL. 0 PLASTIC 36" A. AND 4' 0 Q _ _ 3N r PROVIDED BYr I= LLJ —I 06 N- a D z z TENANT ;' QJ / / \ / / \ / t / s a CO) z z 0 cc X8,01 W �r x a 2'-3' L 2'-0" L L S-0' L L 2'-0' 2'-6' 2--0- 2" 2" BREAKROOM 1 ELEVATION �01 SCALE: 1/2" = 1'-0" 8"15 2'-3" 2'-6" 2'-6" 2'-6" �s1,-Ick, I i I I I � I I I I I I I l 1 CARPET - DIRECT GLUE c1 MFG: PATCRAFT J -4 ko PATTERN: SOUND INVESTMENT Corporate Office COLOR: ESTATE PLANNING vcT1 VINYL COMPOSITION TILE I w MFG: CONGOLEUM I C O O \ PATTERN: CHOICES BASE COLOR: CH17 ANTIQUE WHITE 61 VINYL BASE -4" COVE BASE m- � MANUFACTURER: JOHNSONITE 0 ' W C COLOR: 45 SANDALWOOD / / s V J i 1/4" CLEAR TEMPERED GLASS IN BLDG. STD. FRAME w W cc CO) A L z LL. 0 PLASTIC 36" A. AND 4' 0 Q o 3N F I= LLJ —I 06 N- a D z z a�z Q QJ / 1\ / \ t-1, / t / s a CO) z z 0 cc W x a 2'-3' 2'-6" L 2'-6' L 2'-6- '8n WORKROOM 4 ELEVATION A801 SCALE: 1/2" = 1'-0" NORTH BUILDING STANDARD CABINETRY: TIMBERLAKE CASCADE MAPLE, SQUARE SPICE W/ (2) ADJUSTABLE SHELVES. 4" CHROME —WIRE PULLS. STIC LAMINATE COUNTER A.F.F. WITH 1-1/2" EDGE 4" BACKSPLASH. PL1 „ 1Y" BUILDING STANDARD CABINETRY: TIMBERLAKE CASCADE MAPLE, SQUARE SPICE W/ (1) ADJUSTABLE SHELF. BUILDING STANDARD CABINETRY: - TIMBERLAKE CASCADE MAPLE, SQUARE SPICE W/ (2) ADJUSTABLE SHELVES. 4" CHROME -WIRE PULLS. LAMINATE COUNTER F. WITH 1-1/2" EDGE BACKSPLASH. PL1 BUILDING STANDARD CABINETRY: -TIMBERLAKE CASCADE MAPLE, SQUARE SPICE W/ (1) ADJUSTABLE SHELF. FINISH LEGEND: FLOORCOVERINGS �s1,-Ick, I i I I I � I I I I I I I l 1 CARPET - DIRECT GLUE c1 MFG: PATCRAFT J -4 ko PATTERN: SOUND INVESTMENT Corporate Office COLOR: ESTATE PLANNING vcT1 VINYL COMPOSITION TILE I w MFG: CONGOLEUM I C O O \ PATTERN: CHOICES BASE COLOR: CH17 ANTIQUE WHITE 61 VINYL BASE -4" COVE BASE m- � MANUFACTURER: JOHNSONITE 0 ' W C COLOR: 45 SANDALWOOD PAINT MFG: ICI P1 COLOR: 631 SUDAN SAND FINISH: EGGSHELL P2 MFG: ICI COLOR: 464 BROWN BAG FINISH: SEMI -GLOSS LOCATION: DOOR FRAMES PLASTIC LAMINATE F -PL -1-1 MANUFACTURER: WILSONART COLOR: 4479-60 PEWTER BRUSH FINISH: MATTE FINISH PLAN NOTES aFINISHES TO MATCH EXISTING CORRIDOR FINISHES. GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED TO MATCH EXISTING DOORS. B. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD. C. ALL WOOD TRIM TO BE FINISHED TO MATCH EXISITNG STAIN. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPORVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHEIVE A SMOOTH TRANSITION FROM FINISH TO FINISH F REEBMIT SPPVIADS OF ALL CARPETS PROJECT SCOPE VIWAND AROALLBYESIGNERBEFORERCEDING WITHLOORN6 INSTALLATION. G. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. H. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. I. EXISTING WOOD DOORS AND TRIM THAT ARE TO REMAIN ARE TO BE SANDED AND TOUCHED -UP TO MATCH EXISTING STAIN. J. PAINT NEW OR EXISTING PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL FINISH. K. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. L. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. M. PAINT ALL EXPOSED M AL SURFACES (ie. GRILLS, HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE. N. ALL DRYWALL BULKHEADS ARE TO BE PAINTED (PX), UNLESS OTHERWISE NOTED ON REFLECTED CEILING PLANS. 0. GROUT COLOR TO BE 100% EPDXY, COLOR TO BE SELECTED BY DESIGNER. P. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. BREAKROOM K`2ELEVATION �11 SCALE: 1/2" = 1'-0" 2'-0" 2'-0" 2" WORKROOM 5 ELEVATION �01 SCALE: 1/2" = V-0" )LINTER Q /2" EDGE • PL1 /4" WHITE MELAMINE SHELVING V K&V SHELF BRACKETS (12"DP.) ROVIDE BLOCKING AS REVD. /_ BLOCKING AS NECESSARY -- SINK AND HARDWARE ABOVE, DOOR AND TOEKICK ONE CONTINUOUS PIECE TO MEET ADA REQUIREMENTS. ASTRAGAL ON CABINET DOOR. 3 SECTION SCALE: 1" = V-0" NOTE: A801 SINK PIPES BELOW ARE TO BE WRAPPED FOR COMPLIANCE WITH ADA GUIDELINES. �s1,-Ick, I i I I I � I I I I I I I l 1 rw r r J -4 ko Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @copyright 2001 -- SINK AND HARDWARE ABOVE, DOOR AND TOEKICK ONE CONTINUOUS PIECE TO MEET ADA REQUIREMENTS. ASTRAGAL ON CABINET DOOR. 3 SECTION SCALE: 1" = V-0" NOTE: A801 SINK PIPES BELOW ARE TO BE WRAPPED FOR COMPLIANCE WITH ADA GUIDELINES. RECEPTION 6 ELEVATION A801 SCALE: 1/2" = 1'-0" Duke REALT cortPow►noN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 V rw r r J -4 ko Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @copyright 2001 w V) I w U I C O O \ o t 0 0 m- � N 0 ' W C mC9 -o � / / s V J i 1/4" CLEAR TEMPERED GLASS IN BLDG. STD. FRAME w W RECEPTION 6 ELEVATION A801 SCALE: 1/2" = 1'-0" Duke REALT cortPow►noN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @copyright 2001 w V) I w U I C O O \ 4J \ a0 0 0 m- � N 0 ' W C mC9 -o � U� 0 s V J J w W cc CO) 0 z LL. 0 Q 0 Q o W 3N W I= LLJ —I 06 N- a D z z a�z Q QJ LU o — a -� �- z u. - s a CO) z z 0 cc W x a C e r Y, i�s C, 'i L r �Rt�I910f13& } o �7`ATE;Z?F i• ' ANP Drawing Number: A801 Of Sheets Duke Job Number: A/E Job Number: 24200C