Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
04080103 Building Plans
CLAY TERRACE CARMEL, IN 46033 u KEY PLAN SIGNFAL P I I1__-, • SITE L] LANU,' ANt tlUttt ONOWW VICINITY MAP NQ FINISH NOTES FLOOR TILE FT1 CROSSVILLE, POMPEII SERIES *V650, 18"x18" CERAMIC TILE COLOR: FORUM STONE FTZ CROSSVILLE, POMPEII SERIES OV555, 18"x18" CERAMIC TILE COLOR: LAVA BROWN LONGUST DISTRIBUTING PHONE: (480) 130-3385 FT3 DAL -TILE 6"x6", *OTIO, DIABLO QUARRY RED FLOOR TILE GROUT: CUSTOM GROUT *60 CHARCOAL -SEAL ALL FLOOR TILE GROUT WALL TILE WTl DAL -TILE 4-1/4" x 4-1/4", 00135, ALMOND TILE WAINSCOT 4'-0" A.F.F. ON ALL RESTROOM WALLS. PAINT PTD SHERWIN WILLIAMS - SEMI GLOSS, MORNING SUN CSW 6612), GYP. BOARD CLG, WALLS AND SOFFIT PT2 SHERWIN WILLIAMS (COMMERCIAL DIV) - SHERWOOD 864XXN 1210/4380 - CENTER BROWN WHITE. PT3 PRIME WALLS BEHIND WALL COVERING WITH GARDZ PRIMER BY ZINSSER, PER INSTRUCTIONS AND SPECIFICATIONS ISSUED BY IMAGE CRAFT. WALL COVERING WCl IMAGECRAFT CUSTOM COVERING GSC CUSTOM WALL - RED WC2 IMAGECRAFT CUSTOM COVERING CSC CUSTOM SOFFIT - RED INSTALL PER INSTRUCTIONS 4 SPECIFICATIONS ISSUED BY IMAGE CRAFT. CONTACT: CATHY EUWING 602-216-2082 WWW.IMCRAFT.COM/COL DSTONE CEILING CGI GLOSS -WHITE CEILING GRID CG2 GLOSS -BLACK CEILING GRID ATl WHITE VINYL -FACED GYPSUM BOARD TILES, 2'x 4' AT2 ARMSTRONG, FINE FISSURED, TECH BLACK, 2' x 4' GB1 GYPBOARD CEILING, PAINT PTI. PLASTIC LAMINATE PL1 WILSONART - MATTE, "4166-60 PAMPAS - BACK SERVICE COUNTER TOP, BACKSPLASH, AND CABINET FACES. PL2 FORMICA - MATTE, *1285-58 VIOLIN FIGURED ANNIGRE - WAINSCOT AND DOORS. PROVIDE 3/4" x 3/4" TRIM PIECE FOR WAINSCOT AT ALL OUTSIDE CORNERS. PL3 FORMICA - POLISHED, *211-90 BLACKSTONE - SERVICE COUNTER TOP, SERVICE COUNTER FASCIA AND FACE OF DHEA. PL4 WHITE MELAMINE - INTERIOR CABINETS FRP FIBERGLASS -REINFORCED PLASTIC PANEL SYSTEM. NOTE: PROVIDED AT MOP SINK ENCLOSURE AND WORK AREA, FULL NGT. TILE BASE Bl CROSSVILLE, POMPEII SERIES OV550, 18"x18" CERAMIC TILE COLOR: FORUM STONE. CUT TO CREATE 6" HIGH BASE. B2 CROSSVILLE, POMPEII SERIES OVS55, IS"x18" CERAMIC TILE COLOR: LAVA BROWN. CUT TO CREATE 6" HIGH BASE. CBI DAL -TILE 6"x6", *OTIO, DIABLO QUARRY RED, COVED BASE. CB2 DAL -TILE 4-1/4" x 4-1/4", *3401, ALMOND, COVED BASE RESTROOMS ONLY ELECTRICAL NOTE: ELECTRICAL RECEPTACLES AND OUTLET COVERS TO BE BLACK IN THE LOBBY, IVORY IN THE SERVICE AREA AND WHITE IN THE KITCHEN. BROWN MAY BE SUBSTITUTED IN THE LOBBY WAINSCOT. PROJECT INFORMATION TENANT IMPROVEMENT PLANS PROJECT ADDRESS: CLAP TERRACE, SUITE 528 v CARMEL, IN W i r 3 PROPOSED USE: ICE CREAM SHOP�� v b° SUITE AREA: 1494 S.F. 3� w i co N OCCUPANCY TYPE: MERCANTILE (M) 2 Q a JURISDICTION: CITY OF CARMEL f C 5c). �' a SPRINKLERED: FULLY �Q 6lotwo r y O " v u CONSTRUCTION TYPE: IIN •✓c A'���j ' APPLICABLE CODES, G��� G.:ii 7�S�� b U U O F. , p c 1997 UNIFORM BUILDING CODE (�r (�� U o " A V ° r. p v v C 1997 INDIANA MECHANICAL CODEV� '~ E U " 1993 INDIANA PLUMBING CODE'U c o u , 1991 INDIANA ELECTRICAL CODE U � O OCCUPANCY LOAD FOR EGRESS: c z" G >" EU V 0 PUBLIC (RETAIL): 440 5F / 30 = 14.1 NON-PUBLIC (WORK AREA): 1354 5F / 200 = 53 U U O Z i c TOTAL: 20 OG UP INC EXITS REQUIRED: I (LESS THAN 50 OCCUPANTS) A w c EXITS PROVIDED: I z z o ° H STREET, SUITE 150 PLUMBCO PLUMBING FIXTURE UNT: PUBLIC (RETAIL): 440 SF / 200 = 2.2 A O 5 v c X. ARIZONA 85018 NON-PUBLIC (WORK AREA): 1054 SF / 200 = 53 7 ) 277-7877 PH TOTAL: , (602) 277-8288 FAX OCCUPANT LOAD LE55 THAN 10, THEREFORE (1) UNISEX RESTROOM REQUIRED ENGINEER: PROJECT TEAM CORPORATE: GOLD STONE CREAMERY mo 16101 N. 82nd STREET *A-4 HENDERSON SCOTTSDALE, Az 85260 ENGINEERS PH: (460) 348-1104 FX: (480) 348-1118 SIMON PROPER ROUP INCORPORATED FRANCHISEE: DON SALATICH TENANT COORDI TION 8325LENE AE,X KS DRIVE 66214U11695 00 1424 WYNSTONE COURT RECEIVED TEL: 913-307-5300 69 FAX: 913-307-5400 WEST CHESTER, OH 050 WEB: WWW. HENDERSONENGINEERS.COM FX: ( 513) 159-2814 �y y� qo0 0350000670 FACILITIES FM GROUP INC U MANAGEMENT: 2944 N. 44TH STREET, SUITE 150 ARCHITECT: PHOENIX, AZ 85018 PH: (602) 211-1811 FX: (602) 211-8288 GENERAL NOTES DAVID A. UDKOW DIVISION 1 GENERAL REG2UIIEMENTS 11881 N. 113TH WAY L THE INTENT OF THESE DOCUMENTS IS TO PROVIDE FOR THE 1. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE DISCOVERY, PH: (602) 211-1811 CONSTRUCTION OF THIS PROJECT, COMPLETE AND FUNCTIONAL PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF ELECTRICAL / IN ALL RESPECTS. THE CONTRACTOR SHALL BE RESPONSIBLE PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, 8325 LENEXA DRIVE, STE 400 FOR THIS RESULT. THE OMISSION OF EXPRESS REFERENCE TO INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, ENGINEER: WORK NECESSARY AND REASONABLY INCIDENTAL FOR THE POLYCHLORINATED BIPHENYL (PCB) OR OTHER SUBSTANCES. FX: (913) 301-5400 COMPLETE CONSTRUCTION OF THE PROJECT SHALL NOT BE 5- COMPLY WITH APPLICABLE CODES AND/OR ORDINANCES CONCERNING CONSTRUED AS RELEASING THE CONTRACTOR FROM HIS DEMOLITION OPERATIONS, REFUSE REMOVAL, AND DISPOSAL - RESPONSIBILITIES. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, DIVISION 3 CONCRETE CLEARANCES AND CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK FAILURE TO DO SO CONSTITUTES 1, CLEAN, GRIND AND FILL EXISTING CONCRETE TO ACCEPT VINYL ACCEPTANCE AND RESPONSIBILITY FOR ALL EXISTING CONDITIONS. TILE, CARPET, OR CERAMIC TILE. THE CONTRACTOR WILL NOT BE ALLOWED ADJUSTMENTS IN THE TIME 2_ FLOORS TO RECEIVE TILE OR SHEET VINYL SHALL NOT VARY OR MONEY REQUIRED TO RECTIFY THE SITUATION_ MORE THAN 1/4" PER 10 FEET. 3, DO NOT SCALE DRAWINGS. GIVEN DIMENSIONS SHALL GOVERN. DIVISION 5 METALS LARGE SCALE DRAWINGS SHALL GOVERN OVER SMALL SCALE DRAWINGS. L STEEL FRAMING: WITH EACH TYPE OF METAL FRAMING REQUIRED, 4_ THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL PROVIDE MANUFACTURER'S STANDARD STEEL RUNNER, BLOCKING, PURCHASED, FABRICATED AND FINISHED ITEMS FOR REVIEW BY LINTELS, CLIP ANGELS, SHOES, REINFORCEMENTS, FASTENERS AND THE ARCHITECT UNLESS WAIVED BY THE SAME. ACCESSORIES AS RECOMMENDED BY THE MANUFACTURER FOR THE 5. ALL EQUIPMENT, MATERIALS AND ARTICLES INCORPORATED APPLICATIONS INDICATED. INTO THE PROJECT SHALL BE NEW AND UNDAMAGED. ALL 2. METAL STUDS: OPEN BOX SHAPED SECTIONS, 3-1/2 INCH x 25 GAGE WORKMANSHIP SHALL BE WITHIN INDUSTRY STANDARDS. MIN. (20 GAGE FOR STUDS OVER 14'-0" IN HEIGHT AND AT WALL AT 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND WATER HEATER/MOP SINK ENCLOSURE). REPLACEMENT OF DAMAGE TO AREAS CAUSED BY HIS WORK AT NO ADDITIONAL COST TO THE OWNER DIVISION 1 THERMAL s MOISTURE PROTECTION 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY CONDITIONS RELATING TO JOB CONSTRUCTION INCLUDING A SAFE 1. ALL INSULATING MATERIALS IN CONCEALED SPACES HAVE A FLAME ENVIRONMENT FOR OCCUPANTS OF AREAS ADJACENT TO THE SPREAD RATING OF 15 OR LESS AND A SMOKE DEVELOPED RATING WORK AREA, RATING OF 450 OR LESS PER ASTM E84. 8. THE CONTRACTOR SHALL PAY ALL FEES FOR PERMITS DIVISIONS DOOR$ 4 WINDOWS NECESSARY FOR PROPER COMPLETION OF WORK, UNLESS NOTED OTHERWISE. 1. ALL GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO THE 9. SHOULD THE CONTRACTOR OBSERVE ERRORS, DISCREPANCIES STANDARDS SET FORTH IN THE LOCAL BUILDING CODE. OR OMISSIONS IN THE CONTRACT DOCUMENTS, HE SHALL PROMPTLY 2• ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE NOTIFY THE ARCHITECT REQUESTING CLARIFICATION. THE USE OF A KEY OR SPECIAL KNOWLEDGE. CONTRACTOR SHALL NOT PROCEED WITH WORK AFFECTED BY SUCH ERRORS, DISCREPANCIES OR OMISSIONS WITHOUT RECEIVING 3. MANUALLY OPERATED EDGE OR SURFACE -MOUNTED FLUSH BOLTS CLARIFICATIONS. ADJUSTMENTS INVOLVING SUCH CONDITIONS MADE AND SURFACE BOLTS OR ANY OTHER TYPE OF DEVICE THAT MAY BE BY THE CONTRACTOR WITHOUT PRIOR CLARIFICATION BY THE USED TO CLOSE OR RESTRAIN THE DOOR ARE PROHIBITED. WHERE ARCHITECT, SHALL BE AT THE CONTRACTOR'S OWN RISK EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC FLUSH COMPLICATIONS ARISING FROM PROCEEDING WITHOUT CLARIFICATION BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH SHALL BE RESOLVED AT THE CONTRACTOR'S EXPENSE. BOLTS SHALL HAVE NO DOORKNOB OR SURFACE -MOUNTED HARDWARE. 10, ALL WORK PERFORMED ON THIS PROJECT SHALL COMPLY WITH THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES, LAWS OPERATION. AND ORDINANCES. 4. PANIC HARDWARE, WHERE INSTALLED, SHALL COMPLY WITH THE LOCAL 11, ANYTHING IN THE CONTRACT DOCUMENTS NOT WITHSTANDING, THE BUILDING CODE. THE ACTIVATING MEMBER SHALL BE MOUNTED AT 36 CONTRACTOR ACCEPTS THE RESPONSIBILITY OF CONSTRUCTING A TO 44 INCHES ABOVE THE FLOOR THE UNLATCHING FORCE SHALL NOT WATERTIGHT, WEATHER TIGHT PROJECT. EXCEED 15 POUNDS WHEN APPLIED IN THE DIRECTION OF TRAVEL. 12. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ROOF EQUIPMENT WITH OWNER PRIOR TO INSTALL. CENTER EQUIPMENT DIVISION 9 FINISHES OVER BEAM OR COLUMN UNLESS DIRECTED OTHERWISE BY OWNER 1. INTERIOR FINISHES TO HAVE A MAXIMUM FLAME SPREAD RATING OF 200 13. CONTRACTOR SHALL PROVIDE 2x BLOCKING AT ALL WALL MOUNTED AND MAXIMUM SMOKE DEVELOPMENT RATING OF 450. EQUIPMENT OR ACCESSORIES. 2. STUD PARTITIONS TO BE ANCHORED SO AS TO RESIST A LATERAL 14. ALL SIGNS, INCLUDING WINDOW SIGNS, TO BE SUBMITTED FOR REVIEW AND LOAD OF 5 PSF AS FOLLOWS, BOTTOM PLATE: ANCHOR TO SUB APPROVAL UNDER SEPERATE PERMIT BY OWNER/CONTRACTOR FLOOR WITH 300" POWER DRIVEN PINS AT 48" O.C. ICBG 01639 15. ALL ANGLES AT 45' OR 90" UNO. 3. GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE SMOOTH FINISH, UNLESS NOTED OTHERWISE. DIVISION 2 DEMOLITIONt HAZARDOUS MATERIALS 4_ THE CONTRACTOR SHALL PROVIDE AND INSTALL CAULKING WHERE 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION NOT SPECIFICALLY PERFORMED BY OTHER TRADES. REQUIRED TO ALLOW FOR ALL PROPOSED NEW WORK 5. CERAMIC TILE FLOORS SHALL NOT VARY MORE THAN 1/4" PER 10 FEET. 2. PATCH, REPAIR, REPLACE AND FINISH ANY FLOOR, WALL OR CEILING TO MATCH ADJACENT ,AREAS WHERE DEMOLITION DIVISION 10 SPECIALTIES HAS BEEN REQUIRED. 1. SUITE NUMBER OR ADDRESS TO BE POSTED ABOVE DOOR 3. PROVIDE PROPER SHORING AND DISCONNECTION OF ALL UTILITIES 2. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND PRIOR TO DEMOLITION. INSTALLATION / MODIFICATION TO THE FIRE SPRINKLER SYSTEM. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE CONTRACTOR SHALL SUBMIT DRAWING TO GOVERNING AUTHORITY SITE FREE OF DEBRIS, FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WITH WORK. 5_ THE CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER PRIOR DIVISION 12 FURNISHINGS TO START OF WORK, THE REQUIREMENTS FOR CORING OF FLOOR I. ALL MILLWORK TO BE CUSTOM GRADE AS CHOSEN BY OWNER SLAB FOR ALL REQUIRED WORK PROVIDE CASEWORK WITH ALL NECESSARY HARDWARE, HINGES AND PULLS. 6. THE ARCHITECT AND ENGINEERS, AND CONSULTANTS SHALL HAVE NO DIVISION 18 MECHANICAL RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS L VERIFY EXISTING MECHANICAL EQUIPMENT (HVAC) IS IN FULL WORKING MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT ORDER, REPLACE FILTERS THROUGHOUT SYSTEM. LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL 2. VERIFY FRESH AIR SETTING, HUMIDITY CONTROLS, BALANCE, ETC_ (PCB) OR OTHER TOXIC SUBSTANCES. ARE ADEQUATE FOR PROPOSED USE. REPLACE AND/OR MODIFY SYSTEM AS REQUIRED FOR COMPLIANCE WITH LOCAL GOVERNMENTAL AGENCIES REQUIREMENTS. KEY PLAN SIGNFAL P I I1__-, • SITE L] LANU,' ANt tlUttt ONOWW VICINITY MAP NQ FINISH NOTES FLOOR TILE FT1 CROSSVILLE, POMPEII SERIES *V650, 18"x18" CERAMIC TILE COLOR: FORUM STONE FTZ CROSSVILLE, POMPEII SERIES OV555, 18"x18" CERAMIC TILE COLOR: LAVA BROWN LONGUST DISTRIBUTING PHONE: (480) 130-3385 FT3 DAL -TILE 6"x6", *OTIO, DIABLO QUARRY RED FLOOR TILE GROUT: CUSTOM GROUT *60 CHARCOAL -SEAL ALL FLOOR TILE GROUT WALL TILE WTl DAL -TILE 4-1/4" x 4-1/4", 00135, ALMOND TILE WAINSCOT 4'-0" A.F.F. ON ALL RESTROOM WALLS. PAINT PTD SHERWIN WILLIAMS - SEMI GLOSS, MORNING SUN CSW 6612), GYP. BOARD CLG, WALLS AND SOFFIT PT2 SHERWIN WILLIAMS (COMMERCIAL DIV) - SHERWOOD 864XXN 1210/4380 - CENTER BROWN WHITE. PT3 PRIME WALLS BEHIND WALL COVERING WITH GARDZ PRIMER BY ZINSSER, PER INSTRUCTIONS AND SPECIFICATIONS ISSUED BY IMAGE CRAFT. WALL COVERING WCl IMAGECRAFT CUSTOM COVERING GSC CUSTOM WALL - RED WC2 IMAGECRAFT CUSTOM COVERING CSC CUSTOM SOFFIT - RED INSTALL PER INSTRUCTIONS 4 SPECIFICATIONS ISSUED BY IMAGE CRAFT. CONTACT: CATHY EUWING 602-216-2082 WWW.IMCRAFT.COM/COL DSTONE CEILING CGI GLOSS -WHITE CEILING GRID CG2 GLOSS -BLACK CEILING GRID ATl WHITE VINYL -FACED GYPSUM BOARD TILES, 2'x 4' AT2 ARMSTRONG, FINE FISSURED, TECH BLACK, 2' x 4' GB1 GYPBOARD CEILING, PAINT PTI. PLASTIC LAMINATE PL1 WILSONART - MATTE, "4166-60 PAMPAS - BACK SERVICE COUNTER TOP, BACKSPLASH, AND CABINET FACES. PL2 FORMICA - MATTE, *1285-58 VIOLIN FIGURED ANNIGRE - WAINSCOT AND DOORS. PROVIDE 3/4" x 3/4" TRIM PIECE FOR WAINSCOT AT ALL OUTSIDE CORNERS. PL3 FORMICA - POLISHED, *211-90 BLACKSTONE - SERVICE COUNTER TOP, SERVICE COUNTER FASCIA AND FACE OF DHEA. PL4 WHITE MELAMINE - INTERIOR CABINETS FRP FIBERGLASS -REINFORCED PLASTIC PANEL SYSTEM. NOTE: PROVIDED AT MOP SINK ENCLOSURE AND WORK AREA, FULL NGT. TILE BASE Bl CROSSVILLE, POMPEII SERIES OV550, 18"x18" CERAMIC TILE COLOR: FORUM STONE. CUT TO CREATE 6" HIGH BASE. B2 CROSSVILLE, POMPEII SERIES OVS55, IS"x18" CERAMIC TILE COLOR: LAVA BROWN. CUT TO CREATE 6" HIGH BASE. CBI DAL -TILE 6"x6", *OTIO, DIABLO QUARRY RED, COVED BASE. CB2 DAL -TILE 4-1/4" x 4-1/4", *3401, ALMOND, COVED BASE RESTROOMS ONLY ELECTRICAL NOTE: ELECTRICAL RECEPTACLES AND OUTLET COVERS TO BE BLACK IN THE LOBBY, IVORY IN THE SERVICE AREA AND WHITE IN THE KITCHEN. BROWN MAY BE SUBSTITUTED IN THE LOBBY WAINSCOT. PROJECT INFORMATION TENANT IMPROVEMENT PLANS PROJECT ADDRESS: CLAP TERRACE, SUITE 528 v CARMEL, IN W i r 3 PROPOSED USE: ICE CREAM SHOP�� v b° SUITE AREA: 1494 S.F. 3� w i co N OCCUPANCY TYPE: MERCANTILE (M) 2 Q a JURISDICTION: CITY OF CARMEL f C 5c). �' a SPRINKLERED: FULLY �Q 6lotwo r y O " v u CONSTRUCTION TYPE: IIN •✓c A'���j ' APPLICABLE CODES, G��� G.:ii 7�S�� b U U O F. , p c 1997 UNIFORM BUILDING CODE (�r (�� U o " A V ° r. p v v C 1997 INDIANA MECHANICAL CODEV� '~ E U " 1993 INDIANA PLUMBING CODE'U c o u , 1991 INDIANA ELECTRICAL CODE U � O OCCUPANCY LOAD FOR EGRESS: c z" G >" EU V 0 PUBLIC (RETAIL): 440 5F / 30 = 14.1 NON-PUBLIC (WORK AREA): 1354 5F / 200 = 53 U U O Z i c TOTAL: 20 OG UP INC EXITS REQUIRED: I (LESS THAN 50 OCCUPANTS) A w c EXITS PROVIDED: I z z o ° H STREET, SUITE 150 PLUMBCO PLUMBING FIXTURE UNT: PUBLIC (RETAIL): 440 SF / 200 = 2.2 A O 5 v c X. ARIZONA 85018 NON-PUBLIC (WORK AREA): 1054 SF / 200 = 53 7 ) 277-7877 PH TOTAL: , (602) 277-8288 FAX OCCUPANT LOAD LE55 THAN 10, THEREFORE (1) UNISEX RESTROOM REQUIRED ENGINEER: PROJECT TEAM CORPORATE: GOLD STONE CREAMERY mo 16101 N. 82nd STREET *A-4 HENDERSON SCOTTSDALE, Az 85260 ENGINEERS PH: (460) 348-1104 FX: (480) 348-1118 SIMON PROPER ROUP INCORPORATED FRANCHISEE: DON SALATICH TENANT COORDI TION 8325LENE AE,X KS DRIVE 66214U11695 00 1424 WYNSTONE COURT RECEIVED TEL: 913-307-5300 69 FAX: 913-307-5400 WEST CHESTER, OH 050 WEB: WWW. HENDERSONENGINEERS.COM FX: ( 513) 159-2814 �y y� qo0 0350000670 FACILITIES FM GROUP INC U MANAGEMENT: 2944 N. 44TH STREET, SUITE 150 ARCHITECT: PHOENIX, AZ 85018 PH: (602) 211-1811 DRAWING INDEX A-1 PROJECT INFO, FINISH NOTES, GENERAL NOTES, 4 DOOR 4 WALL TYPES A-2 FLOOR / EQUIPMENT PLANS AND EQUIPMENT SCHEDULE A-3 REFLECTED CEIBING PLAN AND FLOOR FINISH PLAN A-4 ELEVATIONS OWNER A-5 DETAILS M-1 MECHANICAL SPECS 4 NOTES/PLUMBING SPECS 4 NOTES *� /� I /� I M-2 MECHANICAL PLAN, SCHEDULES, SYMBOLS 4 DETAIL DOM SALATICH P-1 PLUMBING PLAN, SCHEDULES 4 SYMBOLS '1424 WYNSTONE COURT P-2 PLUMBING RISER 4 DETAILS p E-1 ELECTRICAL LIGHTING/POWER PLANS 4 SYMBOLS LEGEND WEST CHESTER, OH 05706S E-2 ELECTRICAL SCHEDULES, SPECIFICATIONS 4 DETAILS DOOR TYPES PROJECT TITLE D NEW DOOR: SOLID CORE PRE -FINISHED (PL2) BOTH SIDES, 3 -0 x 1'-0" x 1-3/4", PAINT ALL FOUR EDGES BLACK, W/ TIMELY METALDOOR p� p REQUIREMENTS BL SEE SCHEDULE. PER ADA COLD STONE CREAMER`' D2 EXISTING DOOR DOOR TO REMAIN. PROVIDE NEW HARDWARE, IF CLAY TERRACE - SUITE 826 REQUIRED, PER ADA - SEE SCHEDULE. O /� D3 1 NEW DOOR PAIR 3'-0" x '-l' 2" STOREFRONT DOORS WITH CARMEL, IN 46033 KAWNEER DOOR FRAME, ROCKWOOD BLACK, CUSTOM FLAT DOOR PULLS. PER ADA REQUIREMENTS - SEE SCHEDULE NOTE- ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE STORE * 1241 OF A KEY OR SPECIAL KNOWLEDGE. ALL THRESHOLDS SHALL BE A 1; `IAXIMUM OF 1/2" HEIGHT AND BEVELED. PROJECT NO: 04221 HARDWARE SCHEDULE FILE NAME: 04221-1241-AlAwg s��aP�`O \g TFC 0 INTERIOR DOORS Fo DATE: 1/2/04 : No. 33568 = LOBBY / WORK AREA: ENTRANCE LOCKSET, LEVER TYPE, SINGLE-ACTION, CLOSER Sla OF DRAWN BY: CH � iy TOILET ROOM: I P, rr`� PRIVACY SET, LEVER TYPE, SINGLE ACTION, CLOSER, H I WEATHERSTRIPPING. REVIEWED BY: DD EXTERIOR DOORS REV. DESCRIPTION DATE WORK AREA / EXTERIOR: PANIC HARDWARE, CLOSER. LOBBY - EXTERIOR: LOCKSET, LEVER TYPE, CLOSER, WEATHERSTRIPPING. THUMB TURN DEAD50LTS AND MANUAL FLUSH BOLTS ARE PROHIBITED. CITY SUBMITTAL 1/8/04 NOTE: CENTER OF LEVER TO BE INSTALLED 36" ABOVE FINISH FLOOR SHEET TITLE HARDWARE FINISH TO BE BRUSHED STAINLESS. PROJECT INFO, RNISH NOTES, THE DOOR MAY HAVEAS LONG AS THERE SONT A SIGN ON OR ADJACENT O THENDOOR TATIHARDWAINNG THIS DOOR GENERAL NOTES AND MUST REMAIN UNLOCKED DURING BUSINESS HOURS." DOOR 4 WALL TYi=ES WALL TYPES SOWN NEW INTERIOR STUD WALL, SEE DETAIL I/A-5 FOR CONSTRUCTION. SHEET NO. SMOOTH FINISH AT WALL COVERING. EXISTING WALL TO REMAIN. NEW LOW WALL, TOP OF WALL 3'-2" AFF SMOOTH FINISH AT WALL COVERING. NOTE: GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE SMOOTH FINISH, UNLESS NOTED OTHERWISE. N FX: (602) 211-8288 DESIGN DAVID A. UDKOW ARCHITECT: 11881 N. 113TH WAY SCOTTSDALE, AZ 85259 PH: (602) 211-1811 FX: (602) 211-8288 ELECTRICAL / HENDER60N ENGINEERS INC. MECHANICAL / 8325 LENEXA DRIVE, STE 400 PLUMBING LENEXA, KS 66214-1895 ENGINEER: PH: (913) 301-5300 FX: (913) 301-5400 DRAWING INDEX A-1 PROJECT INFO, FINISH NOTES, GENERAL NOTES, 4 DOOR 4 WALL TYPES A-2 FLOOR / EQUIPMENT PLANS AND EQUIPMENT SCHEDULE A-3 REFLECTED CEIBING PLAN AND FLOOR FINISH PLAN A-4 ELEVATIONS OWNER A-5 DETAILS M-1 MECHANICAL SPECS 4 NOTES/PLUMBING SPECS 4 NOTES *� /� I /� I M-2 MECHANICAL PLAN, SCHEDULES, SYMBOLS 4 DETAIL DOM SALATICH P-1 PLUMBING PLAN, SCHEDULES 4 SYMBOLS '1424 WYNSTONE COURT P-2 PLUMBING RISER 4 DETAILS p E-1 ELECTRICAL LIGHTING/POWER PLANS 4 SYMBOLS LEGEND WEST CHESTER, OH 05706S E-2 ELECTRICAL SCHEDULES, SPECIFICATIONS 4 DETAILS DOOR TYPES PROJECT TITLE D NEW DOOR: SOLID CORE PRE -FINISHED (PL2) BOTH SIDES, 3 -0 x 1'-0" x 1-3/4", PAINT ALL FOUR EDGES BLACK, W/ TIMELY METALDOOR p� p REQUIREMENTS BL SEE SCHEDULE. PER ADA COLD STONE CREAMER`' D2 EXISTING DOOR DOOR TO REMAIN. PROVIDE NEW HARDWARE, IF CLAY TERRACE - SUITE 826 REQUIRED, PER ADA - SEE SCHEDULE. O /� D3 1 NEW DOOR PAIR 3'-0" x '-l' 2" STOREFRONT DOORS WITH CARMEL, IN 46033 KAWNEER DOOR FRAME, ROCKWOOD BLACK, CUSTOM FLAT DOOR PULLS. PER ADA REQUIREMENTS - SEE SCHEDULE NOTE- ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE STORE * 1241 OF A KEY OR SPECIAL KNOWLEDGE. ALL THRESHOLDS SHALL BE A 1; `IAXIMUM OF 1/2" HEIGHT AND BEVELED. PROJECT NO: 04221 HARDWARE SCHEDULE FILE NAME: 04221-1241-AlAwg s��aP�`O \g TFC 0 INTERIOR DOORS Fo DATE: 1/2/04 : No. 33568 = LOBBY / WORK AREA: ENTRANCE LOCKSET, LEVER TYPE, SINGLE-ACTION, CLOSER Sla OF DRAWN BY: CH � iy TOILET ROOM: I P, rr`� PRIVACY SET, LEVER TYPE, SINGLE ACTION, CLOSER, H I WEATHERSTRIPPING. REVIEWED BY: DD EXTERIOR DOORS REV. DESCRIPTION DATE WORK AREA / EXTERIOR: PANIC HARDWARE, CLOSER. LOBBY - EXTERIOR: LOCKSET, LEVER TYPE, CLOSER, WEATHERSTRIPPING. THUMB TURN DEAD50LTS AND MANUAL FLUSH BOLTS ARE PROHIBITED. CITY SUBMITTAL 1/8/04 NOTE: CENTER OF LEVER TO BE INSTALLED 36" ABOVE FINISH FLOOR SHEET TITLE HARDWARE FINISH TO BE BRUSHED STAINLESS. PROJECT INFO, RNISH NOTES, THE DOOR MAY HAVEAS LONG AS THERE SONT A SIGN ON OR ADJACENT O THENDOOR TATIHARDWAINNG THIS DOOR GENERAL NOTES AND MUST REMAIN UNLOCKED DURING BUSINESS HOURS." DOOR 4 WALL TYi=ES WALL TYPES SOWN NEW INTERIOR STUD WALL, SEE DETAIL I/A-5 FOR CONSTRUCTION. SHEET NO. SMOOTH FINISH AT WALL COVERING. EXISTING WALL TO REMAIN. NEW LOW WALL, TOP OF WALL 3'-2" AFF SMOOTH FINISH AT WALL COVERING. NOTE: GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE SMOOTH FINISH, UNLESS NOTED OTHERWISE. N D2 F A-4 FLOOR / EQUIPMENT PLAN SCALE= 1/4"=1'-m" NORTH KEY NOTES OI NEW TELEPHONE MOUNTING BOARD, O 60" TURNING DIAMETER PER ADA REQUIREMENTS. O PROVIDE 3" GAP BETWEEN SNEEZE GUARD AND ADJACENT EQUIPMENT AND/OR WALL. O LOCATION OF NEW ELECTRICAL PANELS. O PROVIDE 2" DIAMETER HOLE WITH GROMMET AT REGISTER FOR POWER CORD. COORDINATE LOCATION WITH OWNER. O STAINLESS STEEL SPLASH GUARD - COORDINATE WITH OWNER_ O BOTTOM OF HEADER AT 7'-0" AFF, TIMELY METAL FRAME AT CASED OPENING W/ NO STOPS. KEY NOTES (continued.-) O WALL FINISH TO MATCH LOBBY WALL. O NEW FLOOR MOUNTED TRANSFORMER, SEE ELECTRICAL DRAWINGS. lm NEW FLOOR DRAIN -SLOPE TILE TO DRAIN, SEE PLUMBING DRAWINGS FOR EXACT LOCATION 11 NEW ELECTRIC HAND DRYER MOUNTED ON WALL. SEE ELECTRICAL DRAWINGS FOR EXACT MODEL. Schedule of FumM^ FixhjvA Equipment Miscellansom and Additional Items mu u� m wd Z wj�tu m w z (3 DESCRIFTION MAKE / MODEL � O> � 10w O � 0 (>- Z z O +- O w ►- O n Q� U n Q REMARKS FURNITURE coLD STONE CORPORATE sTANDAmn IN 010 ITEM TO BE PURCHASED THROUGH COLD STONE CREAMERY CORPORATE STANDARDS PR)GRAM. F1 2 TRASH RECEPTACLE MODEL 415 DT, BLACK 15GAL. COLD STONE CORPORATE STANDARDS** F2 2 FRONT SERVICE COUNTER CUSTOM MILLWORK SEE DETAIL 6/A-5 F3 1 BACK COUNTER CUSTOM MILLWORK SEE DETAIL 7/A-5 F4 2 SNEEZE GUARD CUSTOM SEE DETAIL 8/A-5 F5 1 STAINLESS STEEL TABLE WITH WHEELS TARRISON #WT -3072 30" x 72" LOCATE PER OWNER F6 6 WIRE RACK (2)48" LONG x 18" DEEP, (4)36" LONG x 18" DEEP F7 2 SPLIT WIRE RACK (MOUNTED ABOVE SINK) 8'-0" LONG x 16" DEEP (SPLIT ONE INTO 2 SECTIONS TO MOUNT ON EACH SIDE OF FAUCET COORDINATE MOUNTING HEIGHT WITH OWNER, F8 1 STAINLESS STEEL TABLE WITH WHEELS TARRISON #WT -2430 24" X 30" F9 1 FLOOR SAFE (LOCATE 6" MIN. FROM WALL) VAULT MASTERS - MODEL CSC 2820 SECURE TO FLOOR PER MFG'RS INSTRUCTIONS F10 3 TABLE BASE AND TOP EMU KISS #955 ADA ACCESSIBLE, TABLE CLEAR HEIGHT 28" F11 6 CHAIR EMU COUPOLE #355 F12 3 VINYL COATED SHELVING CLOSET MAID OR EQUAL- 48" LONG x 16" DEEP, INSTALLED IN KITCHEN AT +7'-6" A.F.F. FVCTUM8 X1 1 24" x 24" MOP SINK FIAT SB -2424 SEE PLUMBING X2 1 WATER HEATER (MOUNTED ABOVE MOP SINK) RUUD ELDR-S40 480/3 6kW QQ WITH 6000 WATT ELEMENTS TOP AND BOTTOM - SEE DETAIL 4/A-5 WIRED FOR SIMULTANEOUS OPERATION X3 1 3 COMP. SINK W/ 2 18" DRAINBOARDS TARRISON #PS3-18LR W/ FISHER 2210 -WB PRE -RINSE SEE PLUMBING X4 2 DIPWELL SERVER 15" DIPWELL 1/4" 3/4" VERIFY MOUNTING WITH COUNTER BUILD -OUT - SEE DETAIL 9/A --5— EXTEND DRAIN LINE TO FLOOR SINK, NO 90' OR SHARP BI=NDS X5 1 WALL HUNG HAND SINK JUST A33338 1/2" 1/2" 2" FISHER #1744 FAUCET X6 2 BLACK, 5 BLADE CEILING FAN HAMPTON BAY 52" HUNTINGTON III, REMOVE LIGHT KIT 115/1 0 DO NOT INSTALL LIGHT KIT. X7 2 FROST TOP FAUCET FISHER FAUCET 3042 3/8" X8 4 12" x 12" FLOOR SINK JOSAM #49020AS-3-45 1/4" SEE PLUMBING X9 0 1 COMP. SINK W/ 18" DRAINBOARD UNIVERSAL STAINLESS 1N1618 -R -D18 SEE PLUMBING X10 0 ELECTRIC HANDICAP DRINKING FOUNTAIN OASIS PLF8SKPE 1/5 4.3 1 3/8" 1-1/2" SEE PLUMBING X11 1 SURFACE MOUNTED HAND SINK JUST SL -1921 -A -GR 1/2" 1/2" 2" FISHER #1744 FAUCET X12 1 WALL HUNG HAND SINK (LAVATORY) AMERICAN STANDARD LUCERNE 1/2" 1/2" 2" SYMMONS S -74-G SELF METERING FAUCET EOMMENT El 1 WALK-IN COOLER MASTER BILT, CP -8-12R8 208-230/1 3/4 ❑-' 5'-8" x 7'-9" COMBINED SIZE IS 11'-7" x 7'-9" OUTLET AT +92" A.F.F. MAINTAIN 2" AIR SPACE AROUND ALL SIDES E2 1 WALK-IN FREEZER 208-230/1 2 ❑-' 5'-8" x T-9" E3 2 FROST TOP ATLAS WF5 120/1 1/3 9.8 6 1 AT INLICONE STRUCTIONSERIMETER PER MANUFACTURERS E4 1 DIPPING CABINET GHEA-12, TO BE ASSEMBLED BY GEN. CONTRACTOR 220/1 1/2 10 TO BE ASSEMBELED BY GENERAL CONTRACTOR E5 1 HARDENING CABINET MASTER-BILT IHC -48 1 230/1 1 1 2 / 11.5 Eli OF OUTLET TA +92" A.F.F. CONTRACTOR TO INSTALL CONDENSATE PAN ASSEMBLY. E6 1 WATER-COOLED BATCH FREEZER COLDELITE LB -502 208-230/3 3 36 E], 1/2" 1" BOTTOM OF OUTLET @ 66" A.F.F. E7 2 CASH REGISTER PANASONIC 5500 POS (REQUIRES PC & DATA CONDITIONED PHONE LINE) 115/1 .028 0.35 67 PROVIDE CAT5 CABLE FROM POS TO PC AND DATA CONDITIONED PHONE LINE, COORDINATE WITH OWNER. E8 3 CONE IRON GOLD MEDAL MODEL 5020 120/1 1.0 8.3 6 BOTTOM OF OUTLETX@FOR 40 FATURE USE E9 1 HOT TOPPING SERVER FSP #82060 120/1 .5 4.2 BOTTOM OF OUTLET @ 40" A.F.F. E10 2 BLENDER VITA -MIX MODEL 35100 W/ 1 EXTRA VITA -MIX 15506 CANNISTER 120/1 2 11.2 BOTTOM OF OUTLET @ 40" A.F.F. Ell 1 REFRIGERATED DISPLAY CASE MASTER-BILT BLG-52 220/1120/1 25 5.9 E12 1 CONVECTION OVEN TURBOFAN E25 110/1 1.6 16.6 BOTTOM OF OUTLET @ +38" A.F.F. ` E13 1 UNDER COUNTER REFRIGERATOR SILVER KING SKR-48 DOUBLE DOOR, CASTERS PROVIDED 115/1 5.5 W/ 3" CASTERS - REMOVE LEGS - 32" MAX HEIGHT BOTTOM OF OUTLET @ +18" A.F.F. E14 1 UNDER COUNTER FREEZER SILVER KING SKF -27 SINGLE DOOR, CASTERS PROVIDED 115/1 6.0 W/ 3 CASTERS - REMOVE LEGS - 32 MAX HEIGHT BOTTOM OF OUTLET @ +18" A.F.F. E15 1 CREDIT CARD MACHINE 115/1 0 E16 1 DIP SERVER D1-1 #92000 120/1 .5 4.2 BOTTOM OF OUTLET @ +38" A.F.F. El 1 REACH -IN FREEZER MASTER-BILT CCR-49DF MISCELLANEOUS REAS M1 1 MENU BOARD CUSTOM COLD STONE CORPORATE STANDARDS** M2 0 P.O.P. SIGNAGE CUSTOM 120/1 0.59 TIOELCI CUUITEINTO EOXTERIOR RATE SIGNAGED TIMER. M3 4 STAINLESS STEEL STRAINER BASKET SYSCO INSERT IN EACH FLOOR SINK M4 3 LIQUID SOAP DISPENSER SYSCO M5 3 PAPER TOWEL DISPENSER SYSCO M6 1 ORIGINALS BOARD 48" x 48" M7 3 WALL GRAPHICS 48" x 48" M8 2 GRANITE STONE - 13 1/2" x 66 1/2 3/4" THICK, POLISHED TOP & SIDES, UNPOLISHED BOTTOM, EASED EDGE. COLOR IMPALA BLACK OR ABSOLUTE BLACK. ADD( OM& REAS Al 1 DESK WITH FILE CABINET AND COMPUTER 115/1 SUPPLIED BY OWNER A2 1 MUZAK SYSTEM 115/1 db COORDINATE W/ OWNER & MUZAK, INSTALL 8 AT +7'-6" A.F,F. A3 2 PHONE - SUPPLIED BY OWNER, COORDINATE MOUNTING HEIGHT W/ OWNER. A4 0 MULTIPLE TIER LOCKERS A5 6 STANCHION POST LAWRENCE METALS - TENSABARRIER 9 2 FIRE EXTINGUISHER 2A:1OBC uaHr FIMRES q L1 36 DOWNLIGHT - LOBBY LSI #26910; SERIES 206V CFL 42W TPL UNIV CLBK DGCF Q 1_2 19 DQWNLIGHT - SERVICE AREA LSI #27282; SERIES 206H CFL 42W TPL UNIV W CL q L3 4 WALL WASH LIGHT - SERVICE AREA LSI #26914; SERIES 206WW CFL 226 QUAD UNIV W LSL 1_4 9 2' x 4' TROFFER LIGHT - WORK AREA LSI #26916; SERIES TG 2X4 432W T8 LBA UNIV q L5 1 SURFACE MOUNT LIGHT - RESTROOM LSI #26918; SERIES 78 11-1/2" 4' 232W T8 UNIV L5 6 EMERGENCY LIGHT LSI #EM -B-120/277, CATALOG #74168 1_7 2 EXIT SIGN LSI #EX 2 R B 120/277 EM, CATALOG #74167 1_8 2 2 LAMP FLUORESCENT 1' x 4' SURFACE FIXTURE PROVIDED BY EQUIPMENT MANUFACTURER INSTALLED BY ELECTRICAL CONTRACTOR LOCATED INSIDE COOLER / FREEZER L9 1 TIMER FOR SIGNAGE INTERMATIC T103 120/1 OO SUPPLIED BY OWNER, INSTALLED BY OTHER CC -0 0-- A G P INC 2944 N. 44TH STREET, SUITE 150 PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ENGINEER: .> t HENDERSON ENGINEERS INCORPORATED 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0350000670 ARCHITECT: DAVID A. MKOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON SALATICH "1424 WYNSTONE COURT WEST CHESTER, OH 05069 PROJECT TITLE COLD STONE CREAMERY CLAY TERiZ4CE - SUITE 928 CARMEL.. IN 46 033 STORE 0 1241 PROJECT NO: 04221 FILE NAME: 04221-1241-42.dwg DATE: 7/2/04 DRAWN BY: CH REVIEWED BY: DD REV. I DESCRIPTION * S t N33568� o �STTp�.� DATE / \ 1 CITY SUBMITTAL 1 -1/8/04 SHEET TITLE FLOOR / EQUIPMENT PLANS AND EQUIPMENT SCHEDULE SHEET NO. A-2 +1 F. ill REFLECTED CEILING PLAN SCALE: I/4" = I' -m" NORTH Lu 0 10' -roll FLOOR FINISH PLAN SCALE: 1/4"=V-011 NORTH KEY NOTES O PAINT (PT1) ON GYPSUM BOARD CEILING (WHERE OCCURS). O2 SOFFIT AT 10'-0" AFF., PAINT BACK AND BOTTOM (PTI). O RECESSED CAN LIGHT FIXTURE_ PROVIDE WALL WASH FIXTURES AT MENU BOARDS, AS INDICATED WITH ARROWS. SPACING OF FIXTURES MUST REMAIN CONSISTANT WITH THI5 PLAN TO MAINTAIN COLD STONE CREAMERY'S LIGHTING CRITERIA. ID REMOVE EXISTING CEILING TILE IF OCCURS. RETURN TO BUILDING STOCK OR DISPOSE OF PER OWNER O NEW OR EXISTING SUSPENDED CEILING GRID. O RE -PAINT EXISTING GRID (IF OCCURS) PER FINISH NOTES. O STEREO SPEAKER PER TENANT_ O SEAL ALL FLOOR TILE GROUT. O NEW FLOOR DRAIN -SLOPE TILE TO DRAIN, SEE PLUMBING DRAWINGS FOR EXACT LOCATION NOTES C 0 �C Fl� E A G P INC 1. FOR EQUIPMENT AND FIXTURE SCHEDULE, SEE SHEET A-2. 2944 N. 44TH STREET, SUITE 150 2. FOR FINISH NOTES, SEE SHEET A-1. PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ARCHITECT: DAVID A. UDKOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON SALATICH 1424 WYNSTONE COURT WEST CHESTER, OH 050ro9 PROJECT TITLE COLD STONE CREAMERY CLAY TERRACE - SUITE 928 CARMEL, IN 46033 STORE 0 1241 PROJECT NO: 04221 A . U0 ;.1 FILE NAME: 04221-1241-A3.dwg ��'�P \ S TF 0 DATE: -1/2/04o.33568`� _ s STS ATE OF DRAWN BY: CH REVIEWED BY: DD , I T REV. I DESCRIPTION DATE / \ I CITY SUBMITTAL 1 -1/8/04 SHEET TITLE REFLECTED CEILING PLAN AND FLOOR FINISH PLAN SHEET NO. A-3 5'-0" FROM LEASE 0 Z A U 0 1 IN 'A' ELEVATION SCALE= 1/4"=1'-0" z W U 0 FROM LEASE L'-IfCJ" 4 -SCJ" .2 -ICJ '+ -V11 0 -ro" IF -SCJ � M7 M7 M6 M7 IL 3 WCl 4 Jr 'D' ELEVATION SCALE: 1/4" =1' -0" 'E' ELEVATION SCALE: 1/4''=l'-011 2 13 ALUCOBOND ARCHITECTURAL CLADDING SYSTEM m 6� 'B' ELEVATION SCALE: 1/4"=l'-011 SCALE: 1/4''=l' -O" 'F' ELEVATION SCALE: I/4" =1'-0" ABOLITE AD 100 WITH GALVANIZED ALUMINUM FINI5H ALUCOBOND ARCHITECTURAL CLADDING SYSTEM BENEATH BLACK CANVAS AWNING ALUMINUM STOREFRONT SYSTEM WITH BRUSHED STEEL FIN15H IN CLEAR GLASS BASE BUILDING CAST STONE N m KEY NOTES O ONE COURSE OF TILE BASE, COVED (C51) ENTIRE LENGTH OF CABINET BASE. O P -LAM WAINSCOT (PL2) 3'-0" FROM FINISH FLOOR. INSTALL WITH WOOD GRAIN IN VERTICAL DIRECTION. PAINT WALL SURFACE BLACK BEHIND SEAMS OR INSTALL 1-2" x 4" BATTONS STAINED TO MATCH CHAIR RAIL. O CUSTOM VINYL WALL COVERING (WCI) APPLIED TO GYPSUM BOARD. PAINT WALLS (PT3) PER MANUFACTURER'S INSTRUCTIONS_ O 4" BIRCH (OR MAPLE) CHAIR RAIL STAINED (PT2). O PAINT (PTI) ON GYPSUM BOARD (WHERE OCCURS). O PROVIDE (PL2) FINISH ON BOTH SIDES OF LOW WALL. O PROVIDE 3" GAP BETWEEN SNEEZE GUARD AND ADJACENT EQUIPMENT AND/OR WALL. O NOT USED. O SOFFIT AT S'-6" AFF., PAINT BACK AND BOTTOM (PTI). 10 ALIGN BOTTOM OF DHEA FLUSH WITH COVED TILE BASE. 11 FIELD VERIFY EXISTING DOOR/WINDOW CONDITIONS, VERIFY WITH OWNER. CONFIRM TEMPERED GLAZING AT REQUIRED LOCATIONS. 12 PLASTIC LAMINATE (PL1)_ 13 PLASTIC LAMINATE (PL2). C4:) PLASTIC LAMINATE (PL3). 15 PLASTIC LAMINATE (PL4). 16 4" HIGH BACKSPLASH - FINISH WITH (PLI). ff NOT USED. 18 CERAMIC TILE BASE, (B1) AND (52) WHERE OCCURS PER FLOOR FINISH PLAN. i9 PROVIDE SUPPORT LEG FOR COUNTERTOP BETWEEN UNDER COUNTER EQUIPMENT. ALL EXPOSED FACES FINI5H TO MATCH CABINETS. 20 NOT USED 21 �o" BIRCH CAP ON TOP OF LOW WALL, STAINED (PT2). NOTES 1. FOR EQUIPMENT AND FIXTURE SCHEDULE, SEE SHEET A-2. 2. FOR FINISH NOTES, SEE SHEET A-1. GROUP INC t 2944 N. 44TH STREET, SUITE 150 PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ARCHITECT: DAVID A. UDKOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON SALATICIS 1424 UJYN-STONE COUNT WEST CHESTER, OW 050ro9 PROJECT TITLE COLD STONE CREAMERY CLAY TERRACE - SUITE 928 CARMEL, IN 46033 STORE 0 1241 PROJECT NO: 04221 FILE NAME: 04221-1241-,44.dwg DATE: x/2/04 No. 33568 z ST'JE OF '� 3 DRAWN BY: CH REVIEWED BY: DD ��u uu�►M REV. DESCRIPTION DATE L_�, I CITY SUBMITTAL 1/8/04 SHEET TITLE ELEVATIONS SHEET NO. A-4 STRUCTURE BRACE WALL TO STRUCTURE ABOVE W/ 2-1/2 25 GA METAL STUDS a 4'-0" ` ` 42" GR MAX ALTERNATE DIRECTION `� `� �� �' ROOF DECKING AREA AND ANCHORED W/ 2-1/4" `� ` �� �� 60" D DRYWALL SCREWS. ATTACH TO TOP PLATE W/ 2-1/2" STUD SCREWS. SLIP TRACK ATTACH TO TOP PLATE W/ ADA SIGNAGE LAY -IN CEILING 2-1/2" STUD SCREWS. 71 3-1/2" METAL STUDS -w 24" O.G. 3-1/2" METAL STUDS a 24" O.C. 3 1/2" SOUND BATTS AT W/ 5/8" TYPE X GYP. BOARD. 3 1/2" SOUND BATTS TENANT SIDE ONLY FULL HEIGHT Z 18" MI FRONT APPROACHES HINGE SIDE APPROACHES W/ 5/8 TYPE X GYP. BD. TOILET ROOM 4 NEW �-3�0" GRAB BAR EACH SIDE. USE TYPE WR DEMISING WALLS USE TYPE WR GYP. BEHIND z �, 2 TILE AND WET AREAS - GYP. BD. WET AREAS. AT WATER CLOSET 18" MI 06" X 48" CLEAR SPACE = = a CONNECT TO CONCRETE FLOOR CONNECT TO CONCRETE FLOOR ,nv W/ .14" DIA. x 2-1/2" LONG RAMSET/ W/ .14" DIA. x 2-1/2" LONG RAMSET/ AT LAVATORY REDHEAD POWDER ACTUATED FASTENERS REDHEAD POWDER ACTUATED FASTENERS 30" X 48" CLEAR SPACE -777j 0777/77 48" O.C. PER ICBG REPORT *1639 48" O.G. PER ICBO REPORT *1639 LATCH SIDE APPROACHES 1TYPICAL NEW WALL SECTIONA TYPICAL NEW DEMISING WALL SECTION .���OILET ROOM H.C. REQUIREMENTS .CLEARANCES AT DOORS SCALE: NONE WATER HEATER 3/4" T4P RELIEF LINE ii li DOWN THRU WALL TO ii DRAIN INTO MOP SINK G.I. PAN UNDER WATER HEATER W/ DRAIN LINE DOWN THRU WALL TO DRAIN II INTO MOP SINK j u PROVIDE FRP ON ALL EXPOSED SURFACES AT MOP SINK ENCLOSURE u I' ;I I` SURFACE MOUNTED 24" x 24" MOP SINK SCALE: NONE WATER HEATER SHALL BE STRAPPED AND BOLTED IN PLACE PER THE MANUFACTURERS RECOMMENDATIONS PER CBC SECTION 510.5. DASHED LINE INDICATES SET ON 3/4" PLYWOOD REQUIRED CLEARANCE OF SHELF OVER METAL OPTION UNDER FIXTURE ENCLOSURE / FRAMING — INTERMEDIATE 3-1/2" MIRROR MIRROR SCALE= NONE 25 PTI 24" 12"M �1-1/2" TO 1-3/4" 1-1/2" r PLYWOOL AS RE( GRAB BAR DETAIL 54" MIN_ "MAX 42" MIN PT1 25 35 m 20 GAGE HORIZONTAL 0 Q X `� TOE coO STUD N F d CLEARANCE F Q X 3l m - CONTINUOUS TRACK, w `r z ATTACH TO STUD W/ _� (P = 8" z m '�t = O - m (2) *10 SGREWS. ` N , N 36 am MIN. 11" MIN 6u MAX. FIXTURE DEPTH 15" MIN. 42" IS" FINISH FLOOR c_ FINISH FLOOR MIN. CLEAR TO — 3-1/2"x20 CSA. MTL. STUDS LEG CLEARANCE 1� MIN. FINISH FLOOR LAVATORY OR WALL 12" O.C. -a ALL WALLS SUPPORTING WATER HEATER PLATFORM A TYPICAL LAVATORY B)ROOM TOILET C TYPICAL TOILET SIDE ELEVATION ELEVATION SIDE ELEVATION WATER HEATER/MOP SINK DETAIL TOILET ROOM H.C. REQUIREMENTS SCALE: NONE 30" BACK COUNTER SCALE: NONE DIPPING WELL MOUNTING SCALE: 1" = 1'-0" 24 SNEEZE GUARD SCALE: 1" = 1'-0" 24 23 12" 23 FLOOR SINK ENCLOSURE -PLAN VIEW 24 ZE GUARD 1/8" 1 EDGE OF COUNTER SCALE: NONE FRONT COUNTER SCALE: 1" = 1'-0" TYP. CEILING GRID SUSPENSION FOR LAY -IN ACOUSTICAL PANELS 1" = 1'-0" \ •/ SCALE: NONE EXISTING BUILDING STRUCTURE KEY NOTES Oi CLEAR GLASS SNEEZE GUARD - SEE DETAIL 9/4-5 FOR MORE INFO, O3/4" MARINE GRADE PLYWOOD GLUED AND SCREWED TO 3/4" EXTERIOR GRADE PLYWOOD CABINET TOP AND BOTTOM SHELF. O EXP05ED COUNTERTOP 5URFACE5 AT BACK COUNTER TO BE PLASTIC LAMINATE CPLD AND/OR PENDING CITY REQUIREMENTS, SOLID SURFACING (TBD). ORESTROOM WALL FINISH TO BE (WTI) TO 4'-0" A.F.F., BASE (C52),AND (PTI) ABOVE TILE WAINSCOT. O LIQUID SOAP DISPENSER (M4). O FROST TOP, SHOWN DASHED FOR CLARITY. O WHITE MELAMINE (PL4) ON SURFACES INSIDE CABINETS. O CERAMIC TILE BASE (CBl). O1-1/2"x1-1/2" ALUMINUM ANGLE FASTENED TO THE CABINET WITH COUNTERSINK SCREWS FLUSH WITH THE FACE OF ANGLE. SILICONE SEALER AT ALL EDGES / JOINTS. 10 3/4"x3/4" FULL HEIGHT ALUMINUM ANGLE AT ALL OUTSIDE CORNERS, TYP_ SILICONE SEALER AT ALL EDGES / JOINTS. I1 SCREW AND GLUE COUNTERTOP TO 2-1/4" x 6" HORIZONTAL HEADER BEAM. 12 PLASTIC LAMINATE (PL3) AT ALL EXTERIOR CABINET FACES. 13 3/4" EXTERIOR GRADE PLYWOOD CABINET- G4) ABINET.14 3/4" EXTERIOR GRADE PLYWOOD DOOR, TYP. WITH PLASTIC LAMINATE (PLU AT ALL FACES, BLOOM 135 HINGE AT TOP OF EACH CABINET DOOR, VERIFY WITH OWNER. 15 3" x 1-1/8" HORIZONTAL MARINE GRADE PLYWOOD MEMBER WITH PLASTIC LAMINATE FINISH (PLU AT ALL EXPOSED FACES. liv PRESSURE TREATED WOOD MEMBERS 5-1/2" HIGH, FASTENED TO EXISTING FLOOR AS REQUIRED. 1D PROVIDE STAINLESS STL FACE PLATE (FULLY WRAP EDGES OF BLOCKING). INSTALL PRIOR TO DIPWELL. SEAL ALL SPACES BETWEEN DIPWELLS AND PLATE PER HEALTH DEPARTMENT. 18 1/2" x 4" HIGH MARINE GRADE PLYWOOD BAGKSPLASH, COVER WITH (PLI). lg C.R_ LAURENGE WATER CLEAR SILICONE WHERE GLASS MEETS. NO GAP BETWEEN PIECES OF GLASS. 20 COUNTERTOP BULLNOSE TO BE RUBBER BUMPER MOULDING 303-1500 (SIZE TO FIT) MANUFACTURED BY OUTWATER PLASTIC INDUSTRIES. COLOR: BLACK 21 BOX OUT OPENING AT BASE CABINET AROUND FLOOR SINK - SEE PLAN FOR LOCATIONS. 22 FLOOR SINK WITH PLASTIC STRAINER BASKET. 23 EXTEND CERAMIC TILE BASE AND FLOOR TILE AROUND FLOOR SINK AT CABINET BASE. 24 CABINET BASE. 25 5/S" MOISTURE RESISTANCE GYP. BOARD. 2(o DIPPER WELL UNIT - VERIFY MODEL W/ EQUIPMENT SCHEDULE. 2 i PROVIDE ADEQUATE BLOCKING TO ALIGN REAR OF DIPPING WELL WITH BULLNOSE MOLDING. 28 3/8" TEMPERED GLASS PANELS, POLISH EXPOSED ENDS ONLY. 29 3/8" TEMPERED GLASS PANELS, BULLNOSE EXPOSED EDGE OF GLASS AND POLISH EXPOSED EDGES. 30 3/8" TEMPERED GLASS VERTICALS AT EACH END, SET IN C.R. LAURENGE WATER CLEAR SILICONE 31 PL,4STIC: L.AI"IINATE 32 C.R. LAURENGE WATER CLEAR SILICONE, CONTINUOUS. 33 POLISH THIS EDGE OF VERTICAL GLASS ONLY. 34 COUNTER TOP. 35 CONTINUOUS FLOW TYPE DISPENSER. 3C HOT WATER AND DRAIN PIPES TO BE INSULATED. 3� LEVER TYPE FAUCETS. 38 TILE BASE (BI) CUT TO 6" HIGH 39 WALL. 40 ONE VERTICAL SUPPORT S" FROM WALL 4'-0" APART. G� 41 TWO "2 SPLAY WIRES PERPENDICULAR TO MAIN RUNNER 42 TWO *2 SPLAY WIRES AT 12'O.C. EACH WAY. 43 OVER 56* FIXTURE SUPPORT DIRECTLY TO STRUCTURE. 44 UNDER 56" FIXTURE PROVIDE (2) 02 SLACK WIRES PLU5 ATTACH 4 CORNERS TO GRID. 45 GL IP 4 CORNERS. 4io LIGHT FIXTURE OR CEILING DIFFUSER. 4i CROSS TEE: HEAVY-DUTY SYSTEM OF GRID/RUNNERS (FOR INTERMEDIATE - DUTY SYSTEM ADDITIONAL WIRES NECESSARY TO RUNNERS 3' FROM ALL FIXTURE CORNERS). IC50 -E5 4071. BLDG. STD5. 25.2.0 48 SEISMIC COMPRESSION STRUT: 12'-0" O.C. 1/2" RIGID STEEL CONDUIT TO BE PLACED OVER VERTICAL WIRE. CUT TUBE TO LENGTH LE55 THAN OPEN SPACING. (IF REQUIRED BY LOCAL JUR151CTION) 49 LAMINATE THE UNDERSIDE OF THE COUNTERTOP AND CABINET BASE AT THE TOE KICK ON THE EMPLOYEE SIDE OF THE FRONT AND BACK COUNTERS BRACE HEADER TO STRUCTURE ABOVE WITH 2-1/2" x 25 GA. METAL STUDS AT 48" O.G. MAX. ALTERNATE DIRECTION AND ANCHORED W/ i (3) 2-1/4" DRYWALL SCREWS ` TOP BOTTOM -y- 5-1/2" 5-1/2" x 25 GA. METAL STUDS AT 24" O.G. W/ 1/2" GYP_ BOARD EACH FACE AS SHOWN LAY -IN CEILING AT 10'-0" A.F.F.' BOTTOM OF SOFFIT AT 8'-6" A.F.F. (,-;�SOFFIT DETAIL SCALE: NT5 (3) SCREWS .0 EXISTING STRUCTURE GROUP INC t 2944 N. 44TH STREET, SUITE 150 PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ENGINEER: �? HENDERSON ENGINEERS INCORPORATED 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0350000670 1 ARCHITECT: DAVID A. UDKOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON SALATIGN -1424 U11'NSTONE COURT WEST CHESTER, ON 05069 PROJECT TITLE COLD STONE CREAMERY CLAY TERRACE - SUITE 528 CARMEL, IN 46033 STORE * 1241 PROJECT NO: 04221 FILE NAME: 04221-1241-A5.dwg DATE: 7/2/04 DRAWN BY: CH REVIEWED BY: DD REV. DESCRIPTION GST No. 33568 �*3 STATE OF DATE CITY SUBMITTAL -1/8/04 SHEET TITLE DETAILS SHEET NO. A-5 AIR CONDITIONING, HEATING, AND VENTILATION SPECIFICATIONS NOT ALL SECTIONS MAY BE USED. REFER TO PLANS. SCOPE OF WORK 1.) ALL WORK INCLUDED UNDER THIS SECTION CONSISTS OF FURNISHING ALL MATERIALS, EQUIPMENT AND LABOR, AND THE PERFORMING OF ALL FUNCTIONS, EXCEPT AS OTHERWISE SPECIFIED HEREIN OR SHOWN ON THE DRAWINGS TO BE PERFORMED BY OTHERS, FOR THE INSTALLATION ALL HEATING AND COOLING EQUIPMENT, PIPING AND ALL DUCTWORK, GRILLES, REGISTERS, ETS., INCLUDING ALL CONNECTIONS TO EACH SYSTEM AS SPECIFIED HEREIN AND SHOWN ON THE DRAWINGS. IT SHALL FURTHER INCLUDED FURNISHING AND INSTALLING ALL MISCELLANEOUS ITEMS REQUIRED FOR THE OPERATION OF THE SYSTEM, WHETHER SPECIFICALLY CALLED OUT OR NOT. COORDINATION 1.) ALL CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATING WORK WITH OTHER TRADES AFFECTED BY EACH OTHERS WORK. CODES AND PERMITS 1.) ALL MATERIALS, EQUIPMENT AND INSTALLATION MUST COMPLY WITH ALL APPLICABLE LAWS, CODES, RULES AND REGULATIONS, REQUIRED BY CITY, COUNTY AND STATE, AS WELL AS FEDERAL REQUIREMENTS. 2.) PERMITS: OBTAIN AND PAY FOR ALL REQUIRED PERMITS, LICENSES AND FEES. 3.) INSPECTIONS: FURNISH OWNER WITH CERTIFICATE OF INSPECTION AND APPROVAL BY LOCAL AUTHORITIES PRIOR TO FINAL ACCEPTANCE OF THE PROJECT BY THE OWNER. ALL WORK MUST BE INSPECTED. PRODUCTS 1.) ALL PRODUCTS SHALL BE NEW AND UNUSED OF ESTABLISHED AND REPUTABLE AMERICAN MANUFACTURERS. ITEMS OF EQUIPMENT USED FOR THE SAME PURPOSE SHALL BE OF THE SAME MANUFACTURER. 2.) SYSTEMS SHALL BE COMPLETE AND OPERABLE. ANY ACCESSORIES REQUIRED FOR THE OPERATION OF THE SYSTEM SHALL BE INCLUDED AS THROUGH SPECIFICALLY INDICATED TO THE PROVIDED. SUCH ACCESSORIES WOULD INCLUDE FILTERS, CONDENSATE DRAINS, RELIEF VALVES, SERVICE VALVES, THERMOSTATS, VIBRATION INSULATORS, ETC. MOTOR STARTERS FOR PRE WIRED EQUIPMENT (AND OTHER PROTECTION AND CONTROL DEVICES) ARE ALSO INCLUDED IN THIS SPECIFICATION. 3.) SPECIFIC REFERENCE TO A MANUFACTURER'S PRODUCT IS ONLY TO ESTABLISH TYPE, QUALITY, AND PERFORMANCE REQUIRED. THESE QUALIFICATIONS ARE IN ADDITION TO THE REQUIREMENTS SHOWN ON THE DRAWINGS AND HEREIN THESE SPECIFICATIONS. LISTING OF ALTERNATE EQUIPMENT MANUFACTURERS SHALL NOT BE CONSTRUED AS AN UNCONDITIONAL APPROVAL OF THE PRODUCTS OF THOSE MANUFACTURERS. SUBSTITUTIONS 1•) SUBSTITUTIONS OF MATERIALS OR PRODUCTS SHOWN HEREIN SHALL BE AT THE OWNER'S, ARCHITECTS, OR ENGINEER'S WRITTEN APPROVAL ONLY WITH COPIES OF APPROVAL SENT TO THE PROJECT FILE. ANY DEVIATION FROM THESE DRAWINGS WILL NOT BE ALLOWED. TEMPERATURE CONTROLS AND WIRING 1.) WIRING IS INCLUDED UNDER THE ELECTRICAL DIVISION OF THE SPECIFICATIONS BUT ALL INTEGRAL STARTERS, CONTROLS, RELAYS AND OTHER DEVICES ARE INCLUDED UNDER THE MECHANICAL DIVISION. ALL EQUIPMENT, DEVICES AND WIRING SHALL CONFORM TO THE NATIONAL ELECTRIC CODE. ALL CONTROLS SHALL BE FURNISHED AND PROPERLY IDENTIFIED WITH INSTRUCTIONS FOR PROPER CONNECTIONS. RESPONSIBILITY FOR PROPER DISCONNECTIONS AND OPERATION IS INCLUDED UNDER THE MECHANICAL CONTRACTORS RESPONSIBILITY. VERIFY ALL VOLTAGES, PHASES AND ELECTRICAL CONNECTIONS WITH THE ELECTRICAL CONTRACTOR BEFORE ORDERING ANY EQUIPMENT, AND IF DISCREPANCIES OCCUR, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR HIS DECISION. DUCTWORK 1.) ALL DUCTWORK AND PLENUMS SHALL BE GALVANIZED SHEET METAL. FABRICATE AND INSTALL ALL DUCTWORK IN STRICT CONFORMANCE WITH THE LATEST SMACNA MANUAL, AND APPROPRIATE MECHANICAL CODE FOR LOW VELOCITY DUCT CONSTRUCTION STANDARDS. 2.) EACH DUCT SYSTEM SHALL BE COMPLETE WITH ALL REQUIRED DUCTWORK FITTINGS, TURNING VANES, SPLITTER DAMPERS AND SUPPORTS, AND EXTRACTORS AT ALL RIGHT ANGLE TAKEOFFS AND TEES. 3.) DUCTWORK SHALL BE GALVANIZED, PRIME -GRADE, LOCK -FORMING QUALITY STEEL (LFQ) HAVING A GALVANIZED COATING OF 1-3/4 OUNCES. 4.) CROSSBREAK ALL SIDES OF ALL DUCTS. DUCTWORK SHALL BE INSTALLED WITH NO OBJECTIONABLE NOISE, AND CONTRACTOR SHALL PROVIDE ANY ADDITIONAL STIFFENERS REQUIRED. 5.) ALL LONGITUDINAL SEAMS SHALL BE PITTSBURGH LOCK SEAM, HAMMERED FLAT, WITH ALL TRAVERSE JOINTS TAPED WITH 8 OZ. CANVASS AND SEALED WITH ARABOL, AIR TIGHT. 6.) PROVIDE DOUBLE THICKNESS, FACTORY FABRICATED GALVANIZED SHEET STEEL TURNING VANES WITH AIRFOIL CONTOUR IN ALL RIGHT ANGLE ELBOWS, TEES, AND ELBOWS WITH RADIUS LESS THE 1-1/2 TIMES THE WIDTH OF THE DUCT. 7.) ALL ROUND DUCT BRANCH TAKEOFFS SHALL BE PROVIDED WITH 45 DEGREE HIGH EFFICIENTCY TAKE -OFFS. 8.) DUCT SIZES SHOWN ON THE DRAWINGS ARE TO THE INSIDE OF ACOUSTICAL LININGS. INCREASE SIZES OF DUCTS AS REQUIRED TO ACCOMMODATE ACOUSTICAL INSULATION. 9.) DUCTWORK SHALL CONFORM TO DIMENSIONS ON THE DRAWINGS, UNLESS PROHIBITED BY LOCATION OF STRUCTURAL MEMBERS. IN CASE OF CHANGE IN DIMENSIONS, CROSS SECTIONAL AREAS SHALL BE MAINTAINED. 10.) ALL DUCTS SHALL BE SUBSTANTIALLY SUPPORTED WITH HANGERS TO THE STRUCTURE. SUPPORTS SHALL NOT BE PLACED OVER 10 FEET APART ALONG THE LENGTH OF THE DUCT. HANGERS SHALL CONFORM TO ALL SMACNA REQUIREMENTS. 11.) FLEXIBLE ROUND DUCTS TO OUTLETS SHALL BE THERMALFLEX TYPE MKE, A MAXIMUM LENGTH OF 5-0" LONG (ONLY WHERE INDICATED ON THE DRAWINGS). 12.) ALL FACTORY -MADE DUCTS MUST BE CLASS 0 OR 1 AS APPROVED BY THE APPROPRIATE MECHANICAL CODE. ACOUSTICAL LINER 1.) ALL SHEET METAL DUCT AS FOLLOWS: A.) SUPPLY AND RETURN DUCTS 15'-0" FROM UNITS MINIMUM. SCOPE AND THICKNESS: A.) ALL SHEET METAL SUPPLY AND RETURN PLENUMS, RETURN DUCTWORK: 1" ACOUSTICAL LINER. B.) ALL DUCTWORK EXPOSED TO WEATHER (OTHER THAN EXHAUST): 2" C.) MATERIAL: MINIMUM 1-1/2 LB. NEOPRENE OR HEAVY DENSITY COATED FIBERGLASS DUCT LINER SUITABLE FOR VELOCITIES UP TO 4,000 FPM COMPLYING WITH NFPA 90A. D.) APPLICATION: COATED DUCT LINER SHALL BE CUT TO ASSURE OVERLAPPED AND COMPRESSED LONGITUDINAL CORNER JOINTS. APPLY LINER WITH COATED SURFACE FACING THE AIR STREAM AND ADHERED WITH 100' COVERAGE FIRE RETARDANT ADHESIVE. COAT ALL EXPOSED LEADING EDGES AND AL TRANSVERSE JOINTS WITH FIRE RETARDANT ADHESIVE. THE LINER SHALL BE ADDITIONALLY SECURED WITH MECHANICAL FASTENERS WHICH SHALL COMPRESS THE DUCT LINER SUFFICIENTLY TO HOLD IT FIRMLY IN THE PLACE AS FOLLOWS: E.) INSTALLATION FOR VELOCITIES TO 2,000 FPM: FASTENERS SHALL START WITHIN 3" OF THE UPSTREAM TRANSVERSE EDGES OF THE LINER AND 3" FROM THE LONGITUDINAL JOINTS AND SHALL BE SPACED AT A MAXIMUM OF 12" O.C. AROUND THE PERIMETER OF THE DUCT. EXCEPT THAT THEY MAY BE A MAXIMUM OF 12" FROM A CORNER BREAK. ELSEWHERE, THEY SHALL BE MAXIMUM OF 18" O.C. EXCEPT THAT THEY SHALL BE PLACED NOT MORE THAN 6" FROM A LONGITUDINAL JOINT OF THE LINER NOR 12" FROM A CORNER BREAK. COAT ALL EXPOSED JOINTS AND EDGES OF TRANSVERSE JOINTS WITH A FIRE RETARDANT ADHESIVE. THERMAL INSULATION 1.) GENERAL: ALL INSULATION, MATERIAL, COVERINGS, ADHESIVE, VAPOR -BARRIERS AND TAPES SHALL CONFORM TO NFPA 90A, FLAME SPREAD CLASSIFICATION NOT TO EXCEED 25 AND SMOKE DEVELOPMENT, NOT TO EXCEED 50. 2.) ALL RECTANGULAR DUCTS AND ROUND DUCTS SHALL BE INSULATED WITH 2" THICK .75 LB DENSITY FIBERGLASS BLANKET WITH FRK (FOIL REINFORCED KRAFT) VAPOR BARRIER FACING. INSULATION SHALL HAVE A CONDUCTIVITY NOT TO EXCEED 0.27 BTU PER INCH PER SQUARE FOOT PER DEGREE FAHRENHEIT PER HOUR AT 75 DEGREE FAHRENHEIT MEAN TEMPERATURE. 3.) INSULATION SHALL BE WRAPPED TIGHTLY ON THE DUCTWORK WITH ALL CIRCUMFERENTIAL JOINTS BUTTED AND LONGITUDINAL JOINTS OVERLAPPED A MINIMUM OF 2". ADHERE INSULATION TO METAL ON THE BOTTOM OF RECTANGULAR DUCTWORK OVER 24" WIDE WITH 4" STRIP OF INSULATION BONDING ADHESIVE, BENJAMIN FOSTER 85-15, OR EQUAL, AND ADDITIONALLY SECURE INSULATION WITH MECHANICAL FASTENERS AT NOT MORE THAN 18" O.C. ON ALL JOINTS, THE 2" FLANGE OF THE FACING OR THE 2" OVERLAP SHALL BE SECURED USING 9/16" FLARE -DOOR STAPLES APPLIED 6" O.C. AND TAPED WITH MINIMUM 3" WIDE FOIL REINFORCED KRAFT TAPE. ALL PIN PENETRATIONS OR PUNCTURES IN FACING SHALL ALSO BE TAPED. VERTICAL DUCTS SHALL HAVE INSULATION ADEQUATELY SECURED TO PREVENT SLIPPING. 4.) EXHAUST DUCTS SHALL NOT BE INSULATED. GRILLES, REGISTERS AND DIFFUSERS 1.) FURNISH AND INSTALL ALL GRILLES, REGISTERS, CEILING DIFFUSERS AND DOOR GRILLES WHERE INDICATED. THEY SHALL BE OF SIZE AND MODEL SPECIFIED ON THE DRAWINGS. 2•) ALL GRILLES, REGISTERS, AND CEILING DIFFUSERS MUST BE SET FLUSH AND TRUE TO WALL OR CEILING TO PREVENT AIR LEAKAGE AROUND EDGES. ALL UNITS SHALL BE PROVIDED WITH NEOPRENE GASKETING AROUND THE INSIDE OF THE FRAME. 3•) ALL UNITS SHALL BE FACTORY FINISHED, OF COLOR SELECTED BY THE ARCHITECT, OR AS OTHERWISE INDICATED. 4•) PAINT ALL DUCTWORK, TURNING VANES, INSULATION, ETC. THAT IS VISIBLE THROUGH GRILLES, REGISTERS, OR CEILING DIFFUSERS FLAT BLACK. EQUIPMENT 1 •) ALL EQUIPMENT SHALL BE LABELED WITH STEEL TAGS EMBOSSED WITH 1/4" HIGH LETTERS, PERMANENTLY ATTACHED. TAG SHALL CLEARLY INDICATE THE AREA SERVED BY THE EQUIPMENT. FINAL TESTS 1.) BEFORC ACCEPTANCE AND FINAL PAYMENT, IT SHALL BE DEMONSTRATED THAT ALL APPARATUS IS FUNCTIONING PROPERLY AND EFFICIENTLY. THE CONTRACTOR SHALL MAKE A THOROUGH TEST OF EACH SUPPLY, RETURN, AND EXHAUST SYSTEM TO ENSURE THAT EACH DIFFUSER AND REGISTER HAS THE PROPER QUANTITY OF AIR IN ACCORDANCE WITH AABC OR NEBB. GUARANTEE 1.) THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FROM DEFECT OF WORKMANSHIP, AND SHALL REPLACE OR REPAIR WITHOUT ADDITIONAL COST TO THE OWNER ALL DEFECTIVE MATERIAL AND WORKMANSHIP, FOR A PERIOD OF (1) YEAR AFTER COMPLETITON AND ACCEPTANCE. MECHANI CAL GENERAL NOTES 1.) THE CONTRACTOR SHALL DO ALL THE NECESSARY CUTTING OF WALLS AND CEILING. 2.) NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT PERMISSION FROM THE ARCHITECT AND THE ENGINEER. 3.) PATCH AROUND ALL OPENINGS TO MATCH EXISTING CONSTRUCTION. 4.) DUCTWORK CONSTRUCTION AND INSTALLATION INCLUDING SHEET METAL GAUGES, REINFORCEMENT, JOINT SEALING, AIR LEAKAGE, AND DETAILS NOT SPECIFICALLY SHOWN ON DRAWINGS SHALL BE IN ACCORDANCE WITH 2000 IMC CHAPTER 6 LOW VELOCITY DUCT CON`_;TRUCTION STANDARDS. 5.) ALL DUCT DIMENSIONS SHOWN ARE CLEAR DIMENSIONS INSIDE DUCT LINER. 6.) TURNING VANES SHALL BE INSTALLED IN ALL MITERED ELBOWS. 7.) INSTALL A COMPLETE AND WORKING MECHANICAL SYSTEM IN STRICT ACCORDANCE WITH THE APPROPRIATE MECHANICAL CODE AND SMACNA STANDARDS. 8.) COORDINATE EXACT LOCATION OF MECHANICAL EQUIPMENT, AIR DEVICES, PIPING, DUCTWORK, ETC., WITH PLUMING, ELECTRICAL, STRUCTURAL, ARCHITECTURAL AND GENERAL CONTRACTORS DRAWINGS. 9.) WORKMANSHIP: ALL EQUIPMENT APPURTENANCES, DEVICES AND PIPING SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN CONFORMITY WITH THE PROVISIONS AND INTENT OF THE LATE';T EDITION OF THE APPROPRIATE MECHANICAL CODE. 10.) LOCATE ALL EXHAUST AIR OUTLETS 10'-0" MIN. FROM MECHANICAL EQUIPMENT OUTSIDE AIR INTAKES. 11.) LIGHTING LOCATIONS TAKE PRECEDENCE OVER DIFFUSER LOCATION. CONTRACTORS SHALL MAKE NECESSARY ADJUSTMENTS TO DIFFUSERS TO AVOID ANY CONFLICT WITH LIGHTING LAYOUT. 12.) PROVIDE ALL EXHAUST AIR DUCTS WITH BACK DRAFT DAMPER. 13.) PROVIDE VOLUME DAMPER AT EACH AND EVERY SUPPLY AIR BRANCH DUCT TAKE -OFF, EXCEPT OVER HARD CEILINGS. 14.) TAKE -OFF FITTING SHALL BE BELL MOUTH SPIN -IN TYPE WITH QUADRANT DAMPER. 15.) UNDERCUT ALL DOORS TO ROOMS WHERE A SUPPLY DIFFUSER EXISTS BUT NO RETURN GRILLE IS PRESENT BY A MINIMUM OF 1". THIS WILL ALLOW FOR FREE MIGRATION OF RETURN AIR. 16.) CONTRACTOR SHALL CLEAN AND INSPECT ALL EXISTING EQUIPMENT PRIOR TO COMMENCING WORK. NOTIFY BUILDING OWNER OF ANY DYSFUNCTIONAL EQUIPMENT IMMEDIATELY. 17.) CONTRACTOR SHALL INSURE THAT ALL EXISTING MECHANICAL EQUIPMENT IS IN SATISFACTORY WORKING CONDITION SO HE MAY MAKE PROVISIONS IN HIS BID TO ACCOMMODATE ANY REPLACEMENTS REQUIRED. 18.) VERIFY EXACT SIZE, LOCATION, ROUTING, ETC., OF ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, AIR DEVICES, SENSORS, PIPING, ETC., WHICH ARE TO BE REMOVED REPLACED, ABANDONED, REWORKED, ETC., AS REQUIRED AND AS SHOWN ON DRAWINGS. 19.) ALL TEMPERATURE CONTROLS ARE TO BE TESTED, ADJUSTED AND CALIBRATED FOR PROPER OPERATION. 20.) THE GENERAL CONTRACTOR SHALL BRING ALL SURFACES (FLOOR, WALLS, AND CEILINGS) BACK TO ORIGINAL CONDITION AFTER MODIFICATIONS HAVE BEEN MADE. 21.) PROVIDE CLEARANCES AS PER MANUFACTURER'S RECOMMENDATIONS. 22.) PROVIDE EQUIPMENT IDENTIFICATION PER APPROPRIATE MECHANICAL CODE. 23.) INSTALL CLEANOUTS AT EVERY 90 -DEGREE TURN ON AIR CONDITIONING CONDENSATE DRAIN LINES. 24.) MOUNT ALL THERMOSTATS AT 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE, COORDINATE EXACT LOCATION WITH THE ARCHITECT. 25.) IF ABOVE CEILING DUCTWORK IS FABRICATED OF SHEET METAL, HANGERS SHALL BE INSTALLED AS REQUIRED BY LATEST EDITION OF SMACNA HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE. DUCT SIZE: GAUGE: SUPPORT: SPACING: 12" & UNDER 26 GA. (2) 1" X 22 GA. STRAPS ® 10 FT. 13" TO 30" 24 GA. (2) 1 " X 18 GA. STRAPS ® 10 FT. 31 " TO 40" 22 GA. (2) 1 " X 18 GA. STRAPS ® 10 FT. 40" & OVER 20 GA. (2) 1 " X 18 GA. STRAPS @ 10 FT. PLUMBING SPECIFICATIONS SCOPE OF WORK 1.) ALL WORK REQUIRED CONSISTS OF PERFORMING ALL LABOR AND FURNISHING ALL MATERIALS, FIXTURES AND EQUIPMENT REQUIRED TO PROVIDE A COMPLETE PLUMBING INSTALLATION AS INDICATED ON THE DRAWINGS. IT SHALL FURTHER INCLUDE FURNISHING AND INSTALLING ALL MISCELLANEOUS ITEMS REQUIRED FOR THE OPERATION OF THE SYSTEMS, WHETHER SPECIFICALLY CALLED FOR OR NOT. CONNECT ALL EQUIPMENT FURNISHED UNDER OTHER TRADES AS REQUIRED. DETERMINE IN ADVANCE THE SHUT -DOWN OF EXISTING UTILITIES. CODES 1.) ALL MATERIALS, EQUIPMENT AND INSTALLATION MUST COMPLY WITH ALL APPLICABLE LAWS, CODES, RULES, AND REGULATION, REQUIRED BY CITY, COUNTY AND STATE, AS WELL AS FEDERAL REQUIREMENTS. PERMITS 1.) THIS CONTRACTOR SHALL PAY FOR ALL PERMITS, LICENSES AND FEES REQUIRED BY STATE AND LOCAL AUTHORITIES. INSPECTION 1.) FURNISH OWNER WITH CERTIFICATE OF INSPECTION AND APPROVAL BY LOCAL AUTHORITIES PRIOR TO FINAL ACCEPTANCE OF THE PROJECT BY THE OWNER. ALL WORK MUST BE INSPECTED. MATERIALS 1.) WATER PIPING: A. ALL PIPING SHALL CONFORM TO THE REQUIREMENTS OF THE ANSI SAFETY CODE AND BE FREE FROM ALL DEFECTS AND BE PROPERLY IDENTIFIED. B. ABOVE GROUND: SHALL BE TYPE "L" HARD DRAWN COPPER TUBING CONFORMING TO ASTM B 88-72. C. BELOW GROUND: (INSTALLED IN CONCRETE OR UNDER CONCRETE) TYPE "K" SOFT DRAWN COPPER TUBING, CONFORMING TO ASTM B 88-72, SPIRALLY WRAP PIPING BELOW GRADE OR FLOORS WITH 3 LAYERS OF 20 MIL POLYETHYLENE TAPE WITH 1/2 OVERLAP. INSTALL NO PIPING JOINTS BELOW FLOOR. D. ALL COPPER TUBING SHALL UTILIZE SWEAT FITTINGS SOLDERED WITH ASTM B 32, ALLOY SN95, SN94, OR E, LEAD FREE SOLDER. 2.) SOIL, WASTE, AND VENT PIPING: A. CAST IRON: NO -HUB CAST IRON, CISPI 301-72T SPECIFICATION FOR ALL SOIL, WASTE AND VENT PIPING 2 INCHES AND LARGER WITH STANDARD WEIGHT FITTINGS. USE STAINLESS STEEL NO -HUB CAST IRON COUPLINGS THROUGHOUT THE PROJECT. B. GALVANIZED IRON: SCHEDULE 40 STANDARD WEIGHT CONFORMING TO ASTM A72-68, FOR ALL VENT PIPING 1-1/2" AND SMALLER. USE WROUGHT IRON SCREWED FITTINGS TO MATCH PIPE. MAKE ALL SCREWED JOINTS WITH TEFLON TAPE. C. ALL SOIL AND WASTE PIPING 3" AND SMALLER SHALL SLOPE MINIMUM OF 1/4" PER FOOT, PIPING 4" AND LARGER SHALL SLOPE MIN. OF 1/8" PER FOOT. D. ABS: ABS PIPING CONFORMING TO ASTM D2661-78 FOR ALL SOIL, WASTE AND VENT PIPING WITH MATCHING FITTINGS. ABS ABOVE AND BELOW GRADE FOR COMBUSTIBLE CONSTRUCTION OR ALLOWED BY LOCAL JURISDICTION. ABS FOR NON-COMBUSTIBLE CONSTRUCTION BELOW GRADE ONLY. 3.) NOT USED 4.) VALVES: A. SIZE OF SHUT-OFF VALVES, CONTROL VALVES, BALANCING COCKS, UNIONS ETC., SHALL BE FULL LINE SIZE. 5.) PIPE HANGERS: A. PIPE HANGERS SHALL BE MICHIGAN #400 FOR STEEL PIPING,#402 FOR GAS AND COPPER PIPING. SUPPORT PIPING 3/4" AND LESS AT 6'-0" 0/C, 1-1/4" AND SMALLER 8'-0" 0/C, AND PIPING 1-1/2" AND LARGER 10'-0" 0/C. WASTE PIPING SHALL BE SUPPORTED AT 5'-0" 0/C. PROVIDE 3/8" DIA. THREADED ROD PROPERLY BRACED FOR SEISMIC RESTRAINT ZONE 2A. 6.) PIPE INSULATION: A. ALL HOT WATER PIPING AND HOT WATER RETURN PIPING (IF APPLICABLE) SHALL HAVE 1 INCH THICK FIBERGLASS INSULATION WITH ASJ JACKET, HAVING A THERMAL CONDUCTIVITY (K -FACTOR) OF 0.24 AT 85 DEGREES MEAN TEMPERATURE. B. THE MAXIMUM FIRE HAZARD CLASSIFICATION OF THE INSULATION SYSTEM SHALL NOT HAVE MORE THAN A FLAME SPREAD OF 25, AND A FUEL CONTRIBUTED RATING OF 50, AND A SMOKE DEVELOPED RATING OF 50, WHEN TESTED IN ACCORDANCE WITH U.L. REQUIREMENTS. PIPE COVERING SHALL BEAR THE U.L. LABEL. C. INSULATE ALL FITTINGS VALVE BODIES ETC. WITH SINGLE OR MULTIPLE LAYERS OF INSULATION WITH PREFABRICATED FITTINGS WITH P.V.C. JACKETS. D. SUBMIT SHOP DRAWINGS FOR ALL INSULATION MATERIALS. 7.) CLEAN OUTS: (ZURN, JOSAM, SMITH) A. CLEAN OUTS SHALL BE THE SAME SIZE AS THE LARGEST DOWNSTREAM PIPE IT IS SERVING. NO PLASTIC CLEAN OUTS WILL BE ACCEPTED, PLUGS SHALL BE BRONZE. 8.) PIPE INSTALLATION: A. INSTALL PIPING TO BEST SUIT FIELD CONDITIONS, COORDINATE LAYOUT OF PIPING WITH DUCT WORK AND OFFSET PIPING AS REQUIRED TO CLEAR NEW DUCTWORK. REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER. THIS CONTRACTOR SHALL FURNISH AND INSTALL A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER (BFP) AS SCHEDULED ON THE DRAWINGS, IF REQUIRED BY LOCAL CODE, AND A PRESSURE REDUCING VALVE (PRV) AS REQUIRED ON THE DOMESTIC WATER SERVICE, IMMEDIATELY DOWNSTREAM FROM THE POINT OF WATER SERVICE ENTRY. PROVIDE PRESSURE REDUCING VALVE WHEN DOMESTIC WATER PRESSURE EXCEEDS 80 PSI. ELECTRIC WATER HEATER: WATER HEATERS SHALL BE BY A. 0. SMITH, BRADFORD -WHITE, LOCHINVAR STATE, RHEEM OR RUUD WITH CAPACITY AS SCHEDULED ON THE DRAWINGS. ALL UNITS SHALL BE ELECTRIC GLASSLINED TANK TYPE COMPLETE WITH STEEL JACKET, FIBERGLASS INSULATION, MAGNESIUM ANODE, INTEGRAL THERMOSTATS AND CONTROLS, AND TEMPERATURE & PRESSURE RELIEF VALVE. WATER HEATERS SHALL BE UL LISTED AND MEET ASHRAE 90.113 STANDARDS FOR THERMAL EFFICIENCY AND STANDBY HEAT LOSS. PROVIDE NSF STAMP AND 6" HIGH LEGS AS REQUIRED BY LOCAL AUTHORITY. WATER HEATER ACCESSORIES: RELIEF VALVE: WATER HEATER RELIEF VALVE SHALL BE OF THE TEST LEVER TYPE, WITH AUTOMATIC RESET, COMBINATION TEMPERATURE AND PRESSURE RELIEF, APPROVED AND STAMPED BY THE AMERICAN GAS ASSOCIATION. IT SHALL BE INSTALLED DIRECTLY ON THE HEATER TANK, OR IN THE HOT WATER OUTLET, NOT MORE THAN 3" FROM THE TANK. THE TEMPERATURE SHALL BE NORMALLY SET TO RELIEVE AT 210 F AND THE PRESSURE RELIEF SHALL BE AT 125 PSI. THE RELIEF VALVE DISCHARGE LINE SHALL BE PIPED DOWN AND TERMINATE 6" ABOVE A FLOOR DRAIN. EXPANSION TANK: EXPANSION TANKS SHALL BE AMTROL "THERM-X-TROL" AS SCHEDULED ON THE DRAWINGS OR EQUAL BY ARMSTRONG, BELL & GOSSETT OR TACO. ALL UNITS SHALL BE CONSTRUCTED OF WELDED CARBON STEEL, WITH A FDA APPROVED BUTYL RUBBER DIAPHRAGM, TAPS FOR PRESSURE GAGE, AIR CHARGING FITTING, AND DRAIN FITTING. SUPPORT AS DETAILED ON THE DRAWINGS. CHARGE TANK WITH TO A PRESSURE EQUAL TO THE STATIC WATER PRESSURE. EXISTING CONDITIONS: 1.) THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF ALL UTILITIES PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE WORK HE MUST PREFORM, IN ADDITION TO WHAT IS SHOWN HERE -IN, AND INCLUDE IN HIS BID AN AMOUNT TO DO SUCH WORK. CONDENSATE DRAIN: 1.) PROVIDE FULL SIZED 4" DEEP TRAPPED CONDENSATE DRAIN, COPPER TYPE "M" HARD DRAWN,(SCHEDULE 40 PVC FOR DUCTED RETURN SITUATIONS)FOR EACH AIR CONDITIONING UNIT AND EVAPORATIVE COOLING UNITS. RUN PIPING TO NEAREST FLOOR SINK, LAVATORY TAILPIECE, MOP SINK OR DRAIN OR AS INDICATED ON THE DRAWINGS. SLOPE ALL PIPING MINIMUM OF 1/8" PER FOOT. UNIONS: 1.) PROVIDE A UNION BETWEEN CONNECTIONS TO EACH FIXTURE, DEVICE OR PIECE OF EQUIPMENT FOR DISCONNECTING OF PIPING. STERILIZATION: 1.) STERILIZE THE ENTIRE WATER DISTRIBUTION SYSTEM THOROUGHLY WITH A SOLUTION CONTAINING NOT LESS THAN 50 PARTS PER MILLION OF AVAILABLE CHLORINE. FOR CHLORINATING MATERIALS USE SODIUM HYPOCHLORITE SOLUTION CONFORMING TO FEDERAL SPEC. 0-8-441, GRADE D, AND INTRODUCE INTO THE SYSTEM BY USE OF A COCK AT A SLOW, EVEN, CONTINUOUS RATE. ALLOW THE STERILIZING SOLUTION TO REMAIN IN THE SYSTEM FOR A PERIOD OF 8 HOURS, DURING WHICH TIME ALL VALVES AND FAUCETS SHALL BE OPENED AND CLOSED SEVERAL TIMES. AFTER STERILIZATION, FLUSH THE SOLUTION FROM THE SYSTEM WITH CLEAN WATER UNTIL THE RESIDUAL CHLORINE CONTENT IS NOT GREATER THAN 0.2 PARTS PER MILLION. PLATE COUNT SHALL INDICATE COUNT LESS THAN 100 BACTERIA PER CC. TESTING: 1.) FILL DOMESTIC WATER SYSTEM WITH WATER AND PRESSURIZE TO 125 PSI AND MAINTAIN FOR (4) FOUR HOURS WITH NO PRESSURE DROP. 2•) FILL WASTE, SOIL, AND VENT SYSTEM WITH WATER TO HIGHEST POINT OF THE SYSTEM. HOLD PRESSURE FOR (4) HOURS WITH NO DROP IN WATER LEVEL. 3.) NOTE USED. 4•) TEST AND OBTAIN APPROVAL ON ALL UNDERGROUND PIPING BEFORE COVERING WORK. PROVIDE WRITTEN TESTING REPORT TO ARCHITECT. CLEANING: 1.) AT THE COMPLETION OF THE WORK AND PRIOR TO FINAL ACCEPTANCE,ALL PARTS OF THE WORK INSTALLED UNDER THIS SPECIFICATION SHALL BE THOROUGHLY CLEANED. ALL EQUIPMENT, FIXTURES, PIPE, VALVES AND FITTING SHALL BE CLEANED OF GREASE, METAL CUTTINGS AND SLUDGE WHICH MAY HAVE ACCUMULATED BY OPERATION OF THE SYSTEM FOR TESTING HERE -IN BEFORE SPECIFIED OR FROM OTHER CAUSES. GUARANTEE: 1.) THE CONTRACTORS SHALL GUARANTEE ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FROM DEFECT OF MATERIAL AND WORKMANSHIP, AND SHALL REPLACE OR REPAIR, WITHOUT ADDITIONAL COST TO THE OWNER, ALL DEFECTIVE MATERIAL AND WORKMANSHIP FOR A PERIOD OF (1) YEAR AFTER COMPLETION AND ACCEPTANCE. COORDINATION: 1.) ALL CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATING WORK WITH OTHER TRADES AFFECTED BY EACH OTHERS WORK AND FOR CUTTING AND RE -FINISHING OF EXISTING WALLS, FLOORS, SOLID AND SUSPENDED CEILINGS ETC., WHERE REQUIRED BY WORK SHOWN AND NOTED HERIN. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. ITEMS SUCH AS PIPE, FITTINGS, ETC., SHALL NOT BE INSTALLED IN CONFLICT WITH EQUIPMENT. COORDINATE ALL CUTING AND PATCHING WITH THE GENERAL CONTRACTOR. SUB -CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF HIS WORK. OBTAIN WRITTEN PERMISSION OF ARCHITECT BEFORE PROCEEDING WITH ANY CUTTING OR PATCHING OF STRUCTURAL SYSTEMS. SUBSTITUTIONS: 1 •) SUBSTITUTIONS OF MATERIALS OR PRODUCTS SHOWN HERIN SHALL BE AT THE OWNER'S, ARCHITECT'S OR ENGINEER'S WRITTEN APPROVAL ONLY WITH COPIES OF APPROVAL SENT TO THE ARCHITECT FOR PROJECT FILE. DEVIATION FROM THESE DRAWINGS WILL NOT BE ALLOWED. RECORD DRAWINGS: 1 •) PROVIDE TWO (2) SETS OF "RECORD" DRAWINGS AND TWO (2) BOUND SETS OF ALL OPERATIONS MANUALS, DIAGRAMS, SERVICE CONTRACTS, GUARANTEES, ETC., ONE FOR THE OWNER AND ONE FOR BUILDING OPERATIONS DEPARTMENT. OBTAIN A COMPLETE SET OF RECORD DRAWINGS OF EXISTING CONSTRUCTION FROM THE OWNERS FOR INFORMATION ON EXISTING CONDITIONS. INCORPORATE ANY EXISTING CONDITIONS ON NEW RECORD DRAWING REQUIRED TO SHOW THE "INSTALLED" INSTALLATION. PLUMBING GENERAL NOTES 1.) EXACT LOCATION OF PLUMBING FIXTURES SHALL BE DETERMINED FROM ARCHITECTURAL DRAWINGS. 2.) CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH NEW WASTE LINES ARE TO BE CONNECTED BEFORE MAKING UP OR INSTALLATION OF NEW WASTE SYSTEM. 3.) THE INSTALLATION OF ALL VALVES, UNIONS, THERMOMETERS, GAUGES, OR OTHER INDICATING OR RECORDING EQUIPMENT, OR SPECIALTIES REQUIRING FREQUENT READING, REPAIRS, ADJUSTMENT, INSPECTION, REMOVAL OR REPLACEMENT SHALL BE CONVENIENTLY AND ACCESSIBLY LOCATED WITH REFERENCE TO THE FINISHED BUILDING. 4.) ALL VENTS THROUGH ROOF SHALL BE MINIMUM 10'-0" FROM ALL AIR INTAKES, EVAPORATIVE COOLERS, ETC. 5.) CONTRACTOR SHALL NOT CUT HOLES IN STRUCTURAL MEMBERS WITHOUT FIRST SECURING WRITTEN APPROVAL FROM THE SHELL ARCH./STRUCT. ENGINEER. 6•) CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS. 7•) CONTRACTOR SHALL ROUGH -IN ALL WASTES AND SUPPLIES TO SPECIAL EQUIPMENT ACCORDING TO MANUFACTURERS SHOP DRAWINGS AND MAKE FINAL CONNECTIONS. ALL SUPPLIES SHALL BE VALVED. 8•) WHEN WATER PIPE AND SEWERS ARE LAID PARALLEL TO EACH OTHER, ONE OF THE FOLLOWING PROCEDURES MUST BE FOLLOWED: 8.1) THE HORIZONTAL DISTANCE BETWEEN THE WATER PIPE AND SEWER SHALL NOT BE LESS THAN SIX (6) FEET. EACH LINE SHALL BE LAID IN A SEPARATE TRENCH OR THE SPACE IN BETWEEN FILLED WITH COMPACT FILL. 8.2) THE WATER SERVICE PIPE MAY BE PLACED IN THE TRENCH WITH THE BUILDING DRAIN AND/OR BUILDING SEWER , PROVIDED THE BOTTOM OF THE WATER SERVICE PIPE, AT ALL POINTS SHALL BE AT LEAST TWELVE (12) INCHES ABOVE THE TOP OF THE SEWER LINE, AND SHALL BE PLACED ON A SOLID SHELF EXCAVATED AT ONE SIDE OF THE COMMON TRENCH. SAID WATER SERVICE AND SEWER SHALL BE CONSTRUCTED OF MATERIALS APPROVED FOR USE WITHIN A BUILDING AND PRESSURE TESTED TO ENSURE WATER TIGHTNESS BEFORE BACKFILLING. NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. cuiuD C R E A M t K Y GROUP INC 2944 N. 44TH STREET, SUITE 150 PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ENGINEER: mo u9j HENDERSON ENGINEERS INCORPORATED 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENCINEERS.COM 0450000591 ARCHITECT: DAVID A. UDKOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON 5felLAT I `iH 1424 W rNSTONE COURT WEST CPE5TER, OP 0E�0ro9 PROJECT TITLE COLD STONE CREAMER"'' CLAl" TERRACE - SUITE 528 CARMEL, IN 46033 STORE # 1241 PROJECT NO: 04221All ,e�eaaaats<t/�� �`a1fi FILE NAME: 0450000591MI.dwg aq' 60920153 DATE: 1/2/04 8 T AT E 0 r - DRAWN BY: CDS j�gC REVIEWED BY: KLB1J P l�� REV. DESCRIPTION DATE 0 CITY SUBMITTAL 1/2/04 SHEET TITLE MECHANICAL SPECS & NOTES/PLUMBING SPECS & NOTES SHEET NO. SUPPORT HANGER PER SMACMA REQUIREMENTS RL F RS S-5 1 MECHANICAL FLOOR PLAN SCALE: 11/4"=V-0" N KEYED NOTES: MOUNT PROGRAMMABLE THERMOSTAT FOR EACH FAN COIL UNIT INSIDE DOOR TO KITCHEN AT 48" AFF ON JUNCTION BOX PROVIDED BY ELECTRICAL CONTRACTOR. COORDINATE EXACT LOCATION WITH THE ELECTRICAL CONTRACTOR. LOCATE RETURN AIR TEMPERATURE SENSOR IN RA DUCT. O VOLUME DAMPER SHALL BE ACCESSIBLE FOR ADJUSTMENT. ® GENERAL CONTRACTOR SHALL PROVIDE 1" DOOR UNDERCUT. COORDINATE WITH ARCHITECT. ROUTE 8"0 EXHAUST DUCT UP THRU ROOF TO ROOF CAP. MAINTAIN 10'-0" MINIMUM FROM ALL OUTSIDE AIR INTAKES. © DO NOT ROUTE ANY DUCTWORK OR PIPING OVER ELECTRICAL PANELS. O PROVIDE MINIMUM CLEARANCE PER NEC REQUIREMENTS. ® PROVIDE 5'-0" OF STRAIGHT DUCT PRIOR TO FIRST TAP FROM ROOFTOP UNIT FOR NOISE REDUCTION AND REQUIREMENTS FOR LAMINAR FLOW FROM THE ELECTRIC RESISTANT HEATING ELEMENT. O CONDENSING UNIT (CU) SHALL BE INSTALLED ON ROOF. REFER TO SCHEDULE FOR MORE INFORMATION. 10 TRANSITION FROM ECONOMIZER OUTSIDE AIR OPENING TO ROUND DUCT TO GOOSE NECK ON ROOF. ABBREVIATIONS S=' FROM STRUCTURE' SUPPLY AIR DIFFUSER SCHEDULE FCU -1 AND FCU -2 SUPPLY FANS SHALL OPERATE CONTINUOUSLY WITH FILE NAME: 0450000591M2.dwg RIGID METAL DUCT HP OCCUPIED OPERATION. ELECTRIC HEAT OR CONDENSING UNIT SHALL ENERGIZE AS REQUIRED TO MAINTAIN THERMOSTAT SETPOINT RE: SPECIFICATIONS o PLAN MANUFACTURER MODEL FRAME OBD FINISH REMARKS WITHIN 15 MINUTES, ECONOMIZER OUTSIDE AIR DAMPERS SHALL HR CLOSE TO MINIMUM POSITION AND DX COIL / CONDENSING UNIT SHALL R NALLY ENERGIZE TO MEET SETPOINT. H METAL DRAW BAND OVER MARK WHEN SMOKE DETECTORS OF FCU -1 & FCU -2 ACTIVATE SUPPLY AIR WITH FANS SHALL CONTINUE TO SHUT DOWN. REFRIGERANT LIQUID LINE ALT DUCTWORK (TYPICAL) PRE -INSULATED FLEXIBLE DUCT ---- AS REQUIRED, NOT TO EXCEED S-1 KRUEGER 1400-23 24 x 24 NO WHITE T—BAR CODE SUCTIONLANT INEBUILDING BFF BELOW FINISHED S-2 KRUEGER 1400-23 24 x 24 NO BLACK T—BAR LENGTH OF 5'-0". INSTALL = INSULATE[ PERMANENTLY SEALED AND _ METAL DRAW S-3 KRUEGER 1400-23 24 x 24 NO BLACK SURFACE KILOWATT SO SMOKE DETECTOR SUPPORTED TO PREVENT KINKING OVER INSULA BTUH BTU PER HOUR KEC EQUIPMENT CONTRACTOR S-4 KRUEGER 1400-22 12 X 12 NO WHITE SURFACE AND SHARP TURNS. (TYPICAL) - CEILING DIFFUSER WITH HIGH EFFICIEN OPTIONAL VOLUME NECK - __ DAMPER IF SCHEDULED= - TAKEOFF EXTE == = INSULATED WF S-5 KRUEGER 1240-23 24 x 24 NO WHITE T—BAR CONNECTION LF LINEAL FEET SQ IN SQUARE INCH CUBIC FEET PER R-1 EXHAUST AND RETURN AIR GRILLE SCHEDULE _ = = VOLUME DAMF COORDINATE NOMINAL LAY -IN _ DAMPER LOCK SIZE OR PROVIDE MODULE MOUNTING FRAME FOR HARD EXTENSION CEILING APPLICATION. PLAN MANUFACTURER MODEL FRAME OBD FINISH REMARKS MFG/MFGR DEG DEGREE CEILING MARK ASSOCIATION DIRECT DIGITAL C E'LING DIFFUSER DETAIL R-1 KRUEGER S80H-23 24 x 24 NO WHITE T—BAR R-2 KRUEGER S80H-23 24 x 24 NO BLACK T—BAR TRANSFER AIR ENT ENTERING MUA MAKE UP AIR UNIT TYP R-3 KRUEGER S80H-23 12 x 12 NO WHITE T—BAR 2 NO SCALE R-4 KRUEGER S80H-23 12 x 12 NO BLACK T—BAR EXHAUST FAN SCHEDULE EF MARK SERVICE LOCATION MANUFACTURER MODEL TYPE CFM E.S.P. IN MOTOR HP RPM V PH HZffA, OTES EF -1 RESTROOMS GREENHECK SP -9 100 0.50 DIRECT 129 W 813 120/1/60B,C,D NO NORMALLY OPEN VAC VACUUM FIRE -SMOKE VARIALBE AIR FSD DAMPER NOTES: OUTSIDE AIR A. EQUIPMENT PROVIDED BY MECHANICAL CONTRACTOR. VOLUME B. ELECTRICAL CONTRACTOR SHALL PROVIDE INTERLOCK FOR FAN OPERATION WITH LIGHT SWITCH PER LOCATION ON ELECTRICAL DRAWINGS. C. SUPPLIER SHALL FURNISH EQUIPMENT WITH CABINET FAN SUPPORT ROD KIT 12" ROOF CURB, BACKDRAFT DAMPER, ROOF CAP, SCREEN AND WHITE EXHAUST GRILLE. FLA D. SUPPORT FAN CABINET WITH ALL—THREAD ROD FROM STRUCTURE. FULL LOAD AMPS ROOF HOOD SCHEDULE R" ON CENTER MARK SERVICE MANUFACTURER MODEL CFM MAX. THROAT MAX. PD. THROAT CURB NOTES INTAKE EXHAUST POINT OF VEL. FPM IN DIAMETER L" x W" CONNECTION RH-1 RELIEF GREENHECK GRSR-10 375 600 0.05 10" 19" x 19" A,B,C,D,E CONTRACTOR RH-2 RELIEF GREENHECK GRSR-30 2820 600 0.06 30" 40" x 40" A,B,C,D,E GAL GALLON 0 DIAMETER MECHANICAL SYMBOLS DUCTUJORK / SYMBOLS NOTES: A. EQUIPMENT PROVIDED BY MECHANICAL CONTRACTOR. EXISTING DUCTWORK OR EQUIPMENT TO REMAIN B. SUPPLIER SHALL FURNISH EQUIPMENT AND ALL COMPONENTS BY THE GREENHECK FAN CORPORATION OR EQUAL COOK (LOREN) COMPANY OR ACME ENGINEERING AND MANUFACTURING CORPORATION. C. SUPPLIER SHALL PROVIDE WITH 1/4" ALUMINUM BIRDSCREEN. ROUND DUCT BRANCH TAKEOFFS D. SUPPLIER SHALL PROVIDE WITH MANUFACTURER'S STANDARD INSULATED ROOF CURB WITH MINIMUM HEIGHT OF 15". E. SUPPLIER SHALL PROVIDE WITH INTEGRAL BAROMETRIC OPERATED DAMPER. DEGREE HIGH EFFICIENTCY FCU SPLIT SYSTEM — FAN COIL UNIT SCHEDULE (ELECTRIC HEATING) - ELBOW WITH TURNING VANES FAN COIL MANUAL VOLUME DAMPER BLOWER FAN PERFORMANCE COOLING COIL HEATING COIL RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP MARK SERVICE LOCATION MAN UFACT. MODEL TONS SUPPLY 0/A ESP .x. TC SHC ELEC 1`10TES REGISTER OR GRILLE CFM CFM IN HP V PH HZ MBH (MBH) kw st V/PH HZ DIFFUSER WITH 3 -WAY BLOW FCU -1 SERVICE / LOBBY LENNOX CB29-65 5.0 1850 250 0.50 1/5 480/3/60 55.5 — 25/3 480/3/60 _A THRU Q M1 LOWER NUMBER INDICATES SHEET NUMBER FCU -2 KITCHEN / OFFICE LENNOX CB29-41 3.0 1080 200 0.50 1/5 480/3/60 34.0 — 15/3 480/3/60 A THRU Q NOTES: A. EQUIPMENT PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR. B. EQUIPMENT COOLING CAPACITY BASED ON 80° F DB / 67° F WB EVAPORATOR COIL E.A.T. AND 105°F ENTERING AMBIENT. C. SUPPLIER SHALL FURNISH EQUIPMENT WITH ALL COMPONENTS BY LENNOX INDUSTRIES, INC. OR EQUAL TRANE OR CARRIER. D. SUPPLIER SHALL FURNISH EQUIPMENT WITH 2 SETS OF 1" DISPOSABLE PLEATED FILTERS (FARR 30/30 OR APPROVED EQUAL). PRIOR TO STORE OPENING, MECHANICAL CONTRACTOR SHALL REMOVE SUPPLIER'S FILTERS AND INSTALL CLEAN SET OF FILTERS. E. SUPPLIER SHALL FURNISH EQUIPMENT WITH REMOTE SENSOR, 7 DAY PROGRAMMABLE THERMOSTAT AND SUBBASE WITH STAGED HEATING AND COOLING SWITCH, INCLUDING ACRYLIC, VANDAL PROOF, LOCKING THERMOSTAT COVER. (LOCATION AS SHOWN ON PLANS.) INSTALLED BY MECHANICAL CONTRACTOR. F. SUPPLIER SHALL FURNISH EQUIPMENT WITH ELECTRIC HEAT MODULE, FUSES (3) AND SINGLE—POINT POWER SOURCE CONTROL BOX. ELECTRIC HEAT MODULE FIELD INSTALLED, G. SUPPLIER SHALL FURNISH REFRIGERANT PIPING AND ACCESSORIES WITH EQUIPMENT AND INSTALLED BY MECHANICAL CONTRACTOR. H. SUPPLIER SHALL FURNISH EQUIPMENT WITH EMD14-65 ECONOMIZER DAMPER MODEL WITH ADJUSTABLE THREE POSITION ELECTRONIC SPRING RETURN DAMPER MOTOR AND INTEGRAL 24 VOLT STEP DOWN TRANSFORMER. PROVIDE WIRING HARNESS CATALOG NUMBER 14H57 AND SCHEMATIC FOR PROPER INTERLOCK. J. PROVIDE FLEXIBLE VIBRATION BOOTS AT ALL DUCT CONNECTIONS. K. SUPPLIER SHALL FURNISH EQUIPMENT WITH HORIZONTAL SUPPORT FRAME KIT. SUSPEND FAN COIL UNIT FROM STRUCTURE PER MANUFACTURERS RECOMMENDATIONS. L. PROVIDE SECONDARY DRAIN PAN. M. COORDINATE WITH PLUMBING CONTRACTOR TO PROVIDE SEPARATE CONDENSATE DRAIN PIPING FROM EACH FAN COIL AND EACH SECONDARY DRAIN PAN TO MOP SINK WITH CODE APPROVED AIR GAP. M. DIVISION 16 SHALL PROVIDE LOW VOLTAGE CONTROL WIRING IN CONDUIT FOR REMOTE CONTROL OF UNIT. P. DIVISION 16 SHALL PROVIDE SMOKE DETECTORS IN SUPPLY AND RETURN AIR DUCTS. Q. INSTALL BOTTOM OF UNIT AT 1'-6" ABOVE CEILING ELEVATION FOR FILTER RACK ACCESS. SPLIT SYSTEM — CONDENSING UNIT SCHEDULE cU MARK SERVICE LOCATION MANUFACTURER MODEL TC MBH V PH HZ NOTES CU -1 SERVICE / LOBBY LENNOX HS -29-060 55.5 460/3/60 A, B, C,D,E CU -2 KITCHEN / OFFICE LENNOX HS -29-036 34.0 460/3/60 A,B,C,D,E NOTES: A. EQUIPMENT PROVIDED BY MECHANICAL CONTRACTOR. B. EQUIPMENT COOLING CAPACITY BASED ON 80° F DB / 67° F WB EVAPORATOR COIL E.A.T. AND 105°F ENTERING AMBIENT. C. SUPPLIER SHALL FURNISH EQUIPMENT WITH LIQUID LINE FILTER DRYER AND SIGHT GLASS. D. SUPPORT UNIT ON 4" x 4" TREATED WOOD SUPPORTS. E. DIVISION 16 SHALL PROVIDE UNIT DISCONNECT SWITCH WITH CIRCUIT PROTECTION AND 120V GFCI OUTLETS ON UNIT CABINET. RL F RS S-5 1 MECHANICAL FLOOR PLAN SCALE: 11/4"=V-0" N KEYED NOTES: MOUNT PROGRAMMABLE THERMOSTAT FOR EACH FAN COIL UNIT INSIDE DOOR TO KITCHEN AT 48" AFF ON JUNCTION BOX PROVIDED BY ELECTRICAL CONTRACTOR. COORDINATE EXACT LOCATION WITH THE ELECTRICAL CONTRACTOR. LOCATE RETURN AIR TEMPERATURE SENSOR IN RA DUCT. O VOLUME DAMPER SHALL BE ACCESSIBLE FOR ADJUSTMENT. ® GENERAL CONTRACTOR SHALL PROVIDE 1" DOOR UNDERCUT. COORDINATE WITH ARCHITECT. ROUTE 8"0 EXHAUST DUCT UP THRU ROOF TO ROOF CAP. MAINTAIN 10'-0" MINIMUM FROM ALL OUTSIDE AIR INTAKES. © DO NOT ROUTE ANY DUCTWORK OR PIPING OVER ELECTRICAL PANELS. O PROVIDE MINIMUM CLEARANCE PER NEC REQUIREMENTS. ® PROVIDE 5'-0" OF STRAIGHT DUCT PRIOR TO FIRST TAP FROM ROOFTOP UNIT FOR NOISE REDUCTION AND REQUIREMENTS FOR LAMINAR FLOW FROM THE ELECTRIC RESISTANT HEATING ELEMENT. O CONDENSING UNIT (CU) SHALL BE INSTALLED ON ROOF. REFER TO SCHEDULE FOR MORE INFORMATION. 10 TRANSITION FROM ECONOMIZER OUTSIDE AIR OPENING TO ROUND DUCT TO GOOSE NECK ON ROOF. ABBREVIATIONS SEQUENCE OF OPERATION: SEQUENCE OF OPERATION (FCU -1, FCU -2) DESCRIPTION ABBREVIATION DESCRIPTION FCU -1 AND FCU -2 SUPPLY FANS SHALL OPERATE CONTINUOUSLY WITH FILE NAME: 0450000591M2.dwg ECONOMIZER DAMPERS AT MINIMUM OUTSIDE AIR POSITION DURING HP OCCUPIED OPERATION. ELECTRIC HEAT OR CONDENSING UNIT SHALL ENERGIZE AS REQUIRED TO MAINTAIN THERMOSTAT SETPOINT DUCT (ADJUSTABLE). BAND FCU -1 AND FCU -2 SHALL COOL SPACE UPON A CALL FOR COOLING WITH TION 100% OUTSIDE AIR ECONOMIZER IF OUTDOOR AIR ENTHALPY IS EQUAL RETURN AIR TO OR LESS THAN 18.0 BTU/LB OF DRY AIR. IF SETPOINT IS NOT MET WITHIN 15 MINUTES, ECONOMIZER OUTSIDE AIR DAMPERS SHALL HR CLOSE TO MINIMUM POSITION AND DX COIL / CONDENSING UNIT SHALL R NALLY ENERGIZE TO MEET SETPOINT. H K,5 ER AND WHEN SMOKE DETECTORS OF FCU -1 & FCU -2 ACTIVATE SUPPLY AIR WITH FANS SHALL CONTINUE TO SHUT DOWN. RL F RS S-5 1 MECHANICAL FLOOR PLAN SCALE: 11/4"=V-0" N KEYED NOTES: MOUNT PROGRAMMABLE THERMOSTAT FOR EACH FAN COIL UNIT INSIDE DOOR TO KITCHEN AT 48" AFF ON JUNCTION BOX PROVIDED BY ELECTRICAL CONTRACTOR. COORDINATE EXACT LOCATION WITH THE ELECTRICAL CONTRACTOR. LOCATE RETURN AIR TEMPERATURE SENSOR IN RA DUCT. O VOLUME DAMPER SHALL BE ACCESSIBLE FOR ADJUSTMENT. ® GENERAL CONTRACTOR SHALL PROVIDE 1" DOOR UNDERCUT. COORDINATE WITH ARCHITECT. ROUTE 8"0 EXHAUST DUCT UP THRU ROOF TO ROOF CAP. MAINTAIN 10'-0" MINIMUM FROM ALL OUTSIDE AIR INTAKES. © DO NOT ROUTE ANY DUCTWORK OR PIPING OVER ELECTRICAL PANELS. O PROVIDE MINIMUM CLEARANCE PER NEC REQUIREMENTS. ® PROVIDE 5'-0" OF STRAIGHT DUCT PRIOR TO FIRST TAP FROM ROOFTOP UNIT FOR NOISE REDUCTION AND REQUIREMENTS FOR LAMINAR FLOW FROM THE ELECTRIC RESISTANT HEATING ELEMENT. O CONDENSING UNIT (CU) SHALL BE INSTALLED ON ROOF. REFER TO SCHEDULE FOR MORE INFORMATION. 10 TRANSITION FROM ECONOMIZER OUTSIDE AIR OPENING TO ROUND DUCT TO GOOSE NECK ON ROOF. ABBREVIATIONS 04221 ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION 9O%jata+t��,,�, I'tg f1T^ f�is FILE NAME: 0450000591M2.dwg ABOVE FINISHED HP HORSEPOWER OR DATE: AFF 609201 w FLOOR HEAT PUMP RA RETURN AIR ARCH ARCHITECT HR HOUR REL RELIEF AIR AUX K,5 AUXILLIALRY IMC INTERNATIONAL MECHANICAL CODE RL REFRIGERANT LIQUID LINE ALT IBC INTERNATIONAL REFRIGERS ALTERNATE CODE SUCTIONLANT INEBUILDING BFF BELOW FINISHED IWG INCHES OF WATER FLOOR GAUGE RTU ROOFTOP UNIT BTM BOTTOM KW KILOWATT SO SMOKE DETECTOR KITCHEN BTUH BTU PER HOUR KEC EQUIPMENT CONTRACTOR S SENSOR CD CONDENSATE DRAIN SS STAINLESS STEEL CONN CONNECTION LF LINEAL FEET SQ IN SQUARE INCH CUBIC FEET PER SHEET METAL & CFM MINUTE LBS POUNDS SMACNA A/C CONTRACTORS NATIONAL MFG/MFGR DEG DEGREE MA UF MANUFACTURER ASSOCIATION DIRECT DIGITAL SHT SHEET DDC CONTROL MAX MAXIMUM EXH/EA EXHAUST MIN MINIMUM TA TRANSFER AIR ENT ENTERING MUA MAKE UP AIR UNIT TYP TYPICAL ESP EXTERNAL STATIC PRESSURE NTS NOT TO SCALE UTR UP THROUGH NATIONAL PIPE ETR EXISTING TO REMAIN NFPA PROTECTION VD VOLUME DAMPER ASSOC. FF FINISHED FLOOR NC NORMALLY CLOSED V VOLTS FD FIRE DAMPER NO NORMALLY OPEN VAC VACUUM FIRE -SMOKE VARIALBE AIR FSD DAMPER OSA/OA OUTSIDE AIR VAV VOLUME VARIABLE FLA FULL LOAD AMPS OC ON CENTER VFD FREQUENCY DRIVE FPM FEET PER MINUTE OBD OPPOSED BLADE DAMPER XFMR TRANSFORMER POINT OF FT FEET POC CONNECTION GENERAL POLYVINYL GC CONTRACTOR PVC CHLORIDE GA GAUGE PH PHASE GAL GALLON 0 DIAMETER MECHANICAL SYMBOLS DUCTUJORK / SYMBOLS DESCRIPTION EXISTING DUCTWORK OR EQUIPMENT TO REMAIN NEW DUCTWORK ROUND DUCT BRANCH TAKEOFFS WITH 45 DEGREE HIGH EFFICIENTCY TAKE -OFFS. ELBOW WITH TURNING VANES MANUAL VOLUME DAMPER RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP \ RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN SUPPLY AIR DUCT UP .x. .y, SUPPLY AIR DUCT DOWN TYPE, CFM OF DIFFUSER; REGISTER OR GRILLE S-1 R_1 AIR DEVICE REFERENCE 425 850 UPPER NUMBER INDICATES AIR DEVICE TYPE LOWER NUMBER INDICATES CFM DIFFUSER WITH 3 -WAY BLOW RTU EQUIPMENT REFERENCE UPPER NUMBER INDICATES EQUIPMENT DESIGNATION 1 LOWER NUMBER INDICATES EQUIPMENT NUMBER DETAIL REFERENCE 1 UPPER NUMBER INDICATES DETAIL NUMBER M1 LOWER NUMBER INDICATES SHEET NUMBER OT THERMOSTAT TS TEMPERATURE SENSOR CONNECTION POINT OF NEW WORK TO EXISTING MD MOTORIZED DAMPER N OTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 2944 N. 44TH STREET, SUITE 150 PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ENGINEER: mo HENDERSON ENGINEERS INCORPORATED 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0450000591 ARCHITECT: DAVID A. UDKOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON SAL,4TICH 1424 UJYNSTO E COURT WE5T CHE5TER, OH OSO(o9 PROJECT TITLE COLD STONE CREAMERY CLAY TERRACE - SUITE 525 CARMEL, IN 46033 STORE # 1241 PROJECT NO: 04221 9O%jata+t��,,�, I'tg f1T^ f�is FILE NAME: 0450000591M2.dwg DATE: -7/2/04 609201 w STA -E. OF DRAWN BY: GDS REVIEWED BY: K,5 REV. DESCRIPTION DATE 0 CITY SUBMITTAL 7/2/04 SHEET TITLE MECHANICAL PLAN, 5CHE DULEJ' , SYM50L5, 4 DETAIL SHEET NO. M-2 ..'� "� 19 5 X8 X4_ a P2 \ —4,>GW— CDN N WCO 4 P2 20 E3 (TYPICAL) a m In0 C) N V E a 'o 0 O `z 0 U rn Lo 0 0 w v E com U m .2 cn 0 U (7 2�j PLUMBING W, SCALE: 1/4"=V-0" '-0" No IBM xw" 21117 EXISTING 2" CW TO REMAIN -Y r� i 16 X7 L _j L_J 17 E3 I ' 18 X4 X8 1 /2„HW Mi h 3/4„CW 1 PLUMBING WATER SCALE: 1/4"=V-0” '-0” ND GAS P LAN AVN PLUMBING SYMBOLS QTY. MARK SYMBOLS ABBREV. DESCRIPTION - W WASTE PIPING - S SEWER PIPING X1 GW GREASE WASTE 4 V VENT PIPING — — CW COLD WATER PIPING — — HW HOT WATER PIPING -- - - -- HWR HOT WATER RETURN PIPING X5 G NATURAL GAS PIPING - ROOF 2 FW FILTERED WATER PIPING FROST TOP FAUCET R.D. ROOF DRAIN LEADER 1 OD ROOF OVERFLOW DRAIN LEADER 2 D CD INDIRECT OR CONDENSATE DRAIN X12 Gy GATE VALVE 2 V GLOBE VALVE BATCH FREEZER RV RAI I VAI VF 1 CV CHECK VALVE r PV PLUG VALVE HUR S.V. SOLENOID VALVE - SOV SHUTOFF VALVE 26 PNV PNEUMATIC VALVE 13 BV BUTTERFLY VALVE —�� 6 FEET PER SECOND DUE TO UNKNOW EXISITNG REDUCER FIXTURE COUNTS. –r� HB HOSE BIBB F_ FIRE SPRINKIFIR PIPINGF FS FLOOR SINK ED FLOOR DRAIN 0 FCO ECO FLOOR OR EXTERIOR CLEANOUT WCO WALL CLEANOUT —d TP TRAP PRIMER O RD / OD ROOF DRAIN/ OVERFLOW DRAIN J� VTR VENT THRROOF POP POSITIVE DISPLACEMENT PUMP CP CENTRIFUGAL PUMP POC POINT OF CONNECTION BETWEEN NEW AND EXISTING PLUMBING EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED) REFER TO PLUMBING FIXTURE SCHEDULE AND PLANS O ARCHITECTURAL EQUIPMENT DESIGNATION NOTE: NOT ALL SYMBOLS MAY APPLY. PLUMBING FIXTURE SCHEDULE* MARK CONNECTION SIZES PLUMB ARCH. FIXTURE DESCRIPTION COLD HOT WASTE VENT BFP BACKFLOW ASSEMBLY WATTS 007QT–S: DOUBLE CHECK VALVE ASSEMBLY WITH STRAINER INSTALLED UPSTREAM. 1-1/4" -- -- HWC ADA WATER CLOSET AMERICAN STANDARD CADET #2292.100: 1.6 GPF, TANK TYPE, PRESSURE ASSISTED, CHURCH ELONGATED WHITE, OPEN–FRONT, SOLID SEAT INSTALLED AT 17 1/2„ __ 3" 2" HUR ADA URINAL AMERICAN STANDARD WASHBROOK, 1.0 GPF, SLOAN REGAL FLUSH VALVE, RIM MOUNTED AT 17" AFF 1 2" 1-1/2 TMV THERMOSTATIC MIXING VALVE POWERS #480. INSTALLED UNDER LAVATORY WITH SET TEMPERATURE AT 100'F. 1/2" 1/2" -- WCO WALL CLEANOUT JR SMITH 4530 CLEANOUT WITH COVER -- -- -- -- FCO FLOOR CLEANOUT JR SMITH 4020 WITH ROUND NICKEL BRONZE TOP -- -- 4" -- ECO EXTERIOR CLEANOUT JR SMITH 4261L CAST IRON DOUBLE FLANGED HOUSING,HEAVY DUTY SECURED SCORIATED CAST IRON COVER BODY. -- _– 4„ –_ FD FLOOR DRAIN JR SMITH 2DO5L: CAST IRON BODY WITH FLASHING COLLAR, ADJUSTABLE 6" SQUARE NICKEL BRONZE STRAINER. USE PUSH–ON JOINT OF OUTLET SIZE AS SHOWN ON PLANS, 1/2" -- 2" 2" TP TRAP PRIMER PRECISION PLUMBING PRODUCTS # PR -500 "PRIME RTTE AND INTEGRAL VACUUM BREAKER. INSTALL THE VALVE AT A MINIMUM OF 12" ABOVE FINISHED FLOOR 1/2" -- -- -- ET EXPANSION TANK AMTROL THERM–X–TROL fST-5 3/4" -- -- -- GI–AF GREASE INTERCEPTOR ABOVE FLOOR JAY R SMITH f8120. 40 POUND GREASE CAPACITY WELDED STEEL CONSTRUCTION WITH 20 GPM FLOW RATE' LOW PROFILE MODEL MOUNTED ON FLOOR BENEATH SINK. 4" 2" GI–BF1 GREASE INTERCEPTOR BELOW FLOOR JAY R SMITH f8050, 100 POUND GREASE CAPACITY WELDED STEEL CONSTRUCTION WITH 50 GPM FLOW RATE' FULLY RECESSED IN FLOOR SLAB WITH HEIGHT EXTENSION AS REQUIRED, TOP OF COVER FLUSH WITH FINISHED FLOOR. 4" 2" GI–BF2 GREASE INTERCEPTOR BELOW FLOOR JAY R SMITH 8050GT, 100 POUND GREASE CAPACITY WELDED STEEL CONSTRUCTION WITH 50 GPM FLOW RATE' AUTOMATIC DRAW–OFF MODEL MOUNTED BELOW FLOOR BENEATH SINK. 4" 2" X1 24"x24" MOP SINK REFERENCE SCHEDULE SHEET A-2 3/4" 3/4" 3" 2" X2 WATER HEATER REFERENCE SCHEDULE SHEET A-2-- X3 3 COMPARTMENT SINK WITH (2) 18 DRAINBOARDS REFERENCE SCHEDULE SHEET A -2 3/4" 3/4" 2" 2" X4 DIPWELL REFERENCE SCHEDULE SHEET A-2, SERVER 15" DIPWELL (BY OWNER) 1/2" -- 3/4" -- X5 WALL HUNG HAND SINK REFERENCE SCHEDULE SHEET- A-2, 1/2" 1/2" 2" 2" X7 FROST TOP FAUCET REFERENCE SCHEDULE SHEET A-2 1/2" -- -- -- X8 FLOOR SINK REFERENCE SCHEDULE SHEET A-2 __ __ 3" 2" X9 1 COMPARTMENT SINK WITH (1) 18" REFERENCE SCHEDULE SHEET A-2 3/4" 3/4" 2" 2" X10 DRINKING HANDICAP REFERENCE SCHEDULE SHEET A-2 1/2" 1/2" 3" 2" X11 SURFAND SINKTED REFERENCE SCHEDULE SHEET A-2 1/2" 2" 1-1/2" X12 ADA WALL HUNG LAVATORY REFERENCE SCHEDULE SHEET A-2 1/2" 1/2' 2" 1-1 /2" E3 FROST TOP REFERENCE SCHEDULE SHEET A-2, BY OWNER 1„ E6 WATER COOLED FREEZER REFERENCE SCHEDULE SHEET A-2,1/2" BY OWNER 1 -- * NOT ALL ITEMS MAY BE USED. KEYED NOTES: O1 COORDINATE AND INSTALL NEW TENANT'S 1" COLD WATER SERVICE LINE BACK TO EXISTING METER. O2 DO NOT ROUTE ANY PIPING OVER ELECTRICAL PANELS. O3 CONDENSATE DRAIN FROM WALK–IN FREEZER AND COOLER NOT REQUIRED WITH CONDENSERS INTEGRAL TO UNIT. 4O 1/2" HOT AND COLD WATER DOWN IN WALL TO SERVE LAVATORY AND WATER CLOSET. O5 FIELD VERIFY EXACT SIZE, LOCATION, DIRECTION OF FLOW, AND INVERT OF EXISTING MALL MAIN WASTE LINE. COORDINATE AND CONNECT NEW TENANT'S WASTE LINE INTO EXISTING MALL'S WASTE MAIN. O1" HOT AND COLD WATER TO WATER HEATER MOUNTED ABOVE MOP SINK. OPROVIDE SEPARATE T&P VALVE PIPING AND DRAIN PAN WASTE PIPING TO TERMINATE OVER FLOOD RIM OF MOP SINK WITH CODE APPROVED AIR GAP. O3/4" HOT AND COLD WATER DOWN IN WALL TO SERVE MOP SINK. O3/4" HOT AND COLD WATER DOWN IN WALL TO SERVE 3–COMP SINK FAUCET. 10 INSTALL 2" INDIRECT WASTE PIPING WITH BOWL DRAIN VALVES TO FLOOR SINK AT 3–COMPARTMENT SINK. 11 1/2" HOT AND COLD WATER DOWN IN WALL TO SERVE WALL MOUNTED SINK. 12 1/2" COLD WATER DOWN IN WALL TO SERVE BATCH FREEZER. 13 COORDINATE AND INSTALL 1" INDIRECT WASTE LINE ROUTED TO NEAREST FLOOR SINK FROM BATCH FREEZER. 14 1/2" HOT WATER AND 3/4" COLD WATER DOWN IN WALL TO SERVICE COUNTER MOUNTED HAND SINK. INSTALL 1/2" COLD WATER TO COUNTER MOUNTED SINK AND INSTALL TWO 1/2" COLD WATER LINES TO BELOW SLAB. 15 COORDINATE AND INSTALL 1/2" COLD WATER LINES BELOW SLAB TO SERVE DIPPER WELLS AND FROST TOP FAUCETS AS INDICATED ON DRAWINGS. 16 COORDINATE AND INSTALL 1/2" COLD WATER TO FROST TOP FAUCET. 17 COORDINATE AND INSTALL 1/2" COLD WATER UNDER EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS TO SERVE FROST TOP FIXTURES. 18 COORDINATE AND INSTALL 1/2" COLD WATER TO DIPPER WELL. 19 COORDINATE AND INSTALL 3/4" INDIRECT WASTE LINE ROUTED TO NEAREST FLOOR SINK FROM DIPPER WELL. 20 COORDINATE AND INSTALL 1" INDIRECT WASTE LINE ROUTED TO NEAREST FLOOR SINK FROM FROST TOP CABINET. 21 COORDINATE WITH GENERAL CONTRACTOR FOR ROOF PENETRATION OF NEW 4"VTR. 22 INSTALL DOUBLE CHECK BACKFLOW PREVENTER ON WING WALL AT 48" AFF. 23 INSTALL SANITARY PIPING TO AVOID CONFLICT WITH COLUMN FOOTING. 24 1" CONDENSATE PIPING TO MOP SINK FROM EACH FAN COIL UNIT AND SECONDARY DRAIN PANS. 25 PROVIDE ROCKWELL OR EQUAL UTILITY GRAD WATER METER WITH REMOTE READER PER LANDLORD'S REQUIREMENTS GENERAL NOTES: 1. FOR WASTE AND VENT SIZING SEE SCHEMATIC ON SHEET P2. 2. REFER TO SHEET A-2 FOR KITCHEN EQUIPMENT SCHEDULE CALLOUTS. 3. ALL FLOOR SINKS WILL HAVE INDIRECT WASTE TO KEEP SEAL. THEREFORE, NO TRAP PRIMERS ARE REQUIRED. 4. ALL PLUMBING INSTALLATION SHALL CONFORM TO THE LATEST VERSION OF THE LOCALLY ACCEPTED PLUMBING CODE. 5. ITEMS LISTED IN THE PLUMBING FIXTURE SCHEDULE AND PLANS NOT REFERENCED BY SHEET A-2 SHALL BE PROVIDED BY THIS CONTRACTOR. WATER CALCULATIONS 04221 QTY. MARK DESCRIPTION FIXTURE TOTAL UNITS 1 X1 MOP SINK 4 4 1 X3 3 COMP. SINK 4 4 2 X4 DIPWELL 2 4 1 X5 HAND SINK - WALL HUNG 2 2 2 X7 FROST TOP FAUCET 1 2 1 X11 HAND SINK - COUNTER TOP 2 2 1 X12 LAVATORY 2 2 1 E6 BATCH FREEZER 1 1 1 HWC HANDICAP WATER CLOSET 5 5 0 HUR I HANDICAP URINAL 5 0 TOTAL FIXTURE_ UNIT_(FU) -____ 26 TOTAL GPM _ 13 NOTE: PIPE SIZED CONSERVATIVELY BASED ON 6 FEET PER SECOND DUE TO UNKNOW EXISITNG FIXTURE COUNTS. PIPE SIZING CHART 1 FU = 2 GPM = 1/2" 10 FU = 8 GPM = 3/4" 30 FU = 20 GPM = 1" NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS–BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. COLD C R E A m C n Y X–J, 2944 N. 44TH STREET, SUITE 150 PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ENGINEER: m10 u9j HENDERSON ENGINEERS INCORPORATED 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0450000591 ARCHITECT: DAVID A. UDKOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON 5ALATICH 1424 UWYNSTONE COURT WEST CHE5TER1 CH 050(o9 PROJECT TITLE COLD STONE CREAMERY CLAY TERRACE - SUITE 525 CARMEL, IN 46033 STORE # 1241 PROJECT NO: 04221 FILE NAME: 0450000591PI.dwg5�'�'�T`t; 920153 ' DATE: 1/2/04 ,�, STA—t: CP DRAWN BY: CDS J' REVIEWED BY: KLB REV. DESCRIPTION DATE Q CITY SUBMITTAL 7/2/04 SHEET TITLE PLUMBING PLAN, SCHEDULES AND SYMBOLS SHEET NO. EXISTING SANITARY 6'S / PIPING TO REMAIN. PLUMBING NOTES: %\ COMPLY WITH ALL LOCAL, COUNTY, AND FEDERAL CODES, "'OOLD fo3wON EXISTING 1" \ VALVED AND 4"VTR ORDINANCES, RULES, AND REGULATIONS. COMPLY WITH ALL REFERENCED COMMERCIAL STANDARDS, CAPPED PIPING ti SPECIFICATIONS, CODES, RULES, ETC. C R E A M E R Y 2'V EXACT LOCATION OF PLUMBING FIXTURES SHALL BE DETERMINED \ T2,V J FROM ARCHITECTURAL DRAWINGS. BEFORE SUBMITTING BID, THE PLUMBING CONTRACTOR SHALL REVIEWm 2" EXISTING- FCO � THE ARCHITECTURAL DRAWINGS AND THE EQUIPMENT DRAWINGS AND COLD WATER WCO 3 SHALL INCLUDE IN HIS BID AN AMOUNT TO FURNISH AND INSTALL ANY " 3 ENTRY I 2' FIXTURES WHICH ARE SHOWN IN ADDITION TO FIXTURES SHOWN ON 1I \� 1„ rJ �6" THE PLUMBING DRAWINGS. YIY \ ADEQUATELY SUPPORT ALL PIPING AGAINST SAGGING, POCKETING, 0X TMV .3/4" 2 J X1 SWAYING AND DISPLACEMENT. PROPERLY SPACE AND APPLY 1 G� 3"W HANGERS PER MSS SP-69. FD CONTRACTOR SHALL ROUGH-IN WASTES AND SUPPLIES TO SPECIAL+ 1/2"CW BFP HWC EQUIPMENT ACCORDING TO MANUFACTURER'S SHOP DRAWINGS AND°. i HWC O X2 MAKE FINAL CONNECTIONS. ALL SUPPLIES SHALL BE VALVED. i I , \ / x3 /e 4"W EXPOSED PIPING OTHER THAN SPECIFICALLY NOTED OTHERWISE - / GROUPN� . FD ��� _ \ � / X8 4 W SHALL BE CHROME PLATED. WHERE WATER PIPES AND VALVES ARE ,.. C) t X8 E610 p GI-BF2 EXPOSED IN TOILET AREAS, PIPING SHALL BE THREADED CHROME AND 1/2" CW �,,� / `? SHALL HAVE CHROME PLATED ESCUTCHEONS AND VALVE AS P2 BELOW FLOOR \ �/ / REQUIRED. 2944 N. 44TH STREET, �SUITE 150 AND ESUB-CONTRACTORSRAL, MECHANICAL, ES ALL COORDINA EAL AND U^THIEIR WORKNG RPRIORSTO PHOENIX, ARIZONA 85018 4„GW INSTALLATION TO PROVIDE FOR PROPER CLEARANCES BETWEEN (602) 277-7877 PH / EQUIPMENT, DUCTWORK, PIPING, JOISTS, CEILINGS, ETC. (602) 277-8288 FAX 3 • / 3 Y SUPPLIER SHALL NOT QUOTE PRICES OR SUPPLY EQUIPMENT TO CONTRACTORS WITHOUT REVIEWING PLANS AND SPECIFICATIONS. c� X3 DOMESTIC WATER PIPING ENGINEER: USE TYPE "L' HARD DRAWN COPPER FOR ALL DOMESTIC WATER LINES ABOVE GRADE AND TYPE "K” SOFT ANNEALED BELOW GRADE. USE WROUGHT COPPER SOLDER TYPE FITTINGS AT ALL COPPER PIPE CN 04 N X4 E3 / / PDI GREASE INTERCEPTOR CALCULATION APPROVED. MECHANICALLY EXTRACTED FITTINGS ARE NOT. MAKE NO JOINTS BELOW CONCRETE SLABS. H E N D E R S O N *� / X8 X7 �°` � ENGINEERS X7 _ .J / 14 FLOOR 1 Count all contributing fixtures, measure and calculate capacities as follows: USE 95-5 TIN-ANTIMONY SOLDER ON ALL SOLDERED JOINTS 1/2" INCORPORATED S-) PENETRATION Rinse Sinks: THROUGH 2"; PREPARE JOINTS WITH SOLVENT AND EMERY CLOTH. 8325 LENEXA DRIVE SUITE 400 �\ X5I (TYPICAL) 3 18 W x 18 L x _ 12 L-u. in / 231 = 50.5_ gallons LENEXA, KS. 66214-1695 I W x L x Cbu. in / 231 = 0.0 - gallons CONTRACTOR SHALL EXTEND WATER PIPING TO ALL FIXTURES, TEL: 913-307-5300 ,, �' W x L x Dbu. in / 231 = 0.0 gallons OUTLETS AND EQUIPMENT. PROVIDE SHUT-OFF VALVES OR FIXTURE FAX: 913-307-5400 W x L x Dku. in / 231 = 0.0 gallons STOPS AS REQUIRED FOR PROPER SERVICE. WEB: WWW. HENDERSONENG I NEERS. COM v X4 E3 / Pot Sinks: 0450000591 X8 X7 WCO 0 W x L x D:u. in / 231 = 0.0 gallons ALL HOT WATER SUPPLY PIPING MAINS SHALL BE INSULATED WITH 1 " / Y W x L x fbu. in / 231 = 0.0 gallons THICK MINIMUM DENSITY 4.0 LBS. PER CUBIC FOOT FIBER GLASS PIPE 1 2"CW / Service Sinks: INSULATION, DROPS SHALL BE INSULATED WITH 1/2" THICKNESS OF THE X4 / / 0 24 W x 24 L x 6 Fku. in 231 / 0.0 gallons SAME. THERMAL CONDUCTIVITY "K" VALUE SHALL NOT EXCEED 0.24 AT ARCHITECT: = EAN WATER RISER \ / ���� 1-A TOTAL = 50.5 gallons EXPOSED ELOCATIONS,TTEMPERATURE. PROVIDE METAL JACKET AT ALL Ox7 C� l---'-----� N0 SCALE / I`L T i 1/2 CW B 2 50.5 Total Gallons from 1-A x 0.75 (fill factors) / 2 minute drain down period = 18.9 GPM SIZE ALL HANGERS ON INSULATED LINES TO FIT AROUND OUTSIDEDIAMETER OF INSULATION SPECIFIED WITH ALLOWANCES FOR DAVID A. UDKOW, ARCHITECT Y WASTCONTRACTOR SHALL VERIFY LOCATION OF EXISTING WATER MAINS E AND VENT RISER 3 0 Number of Floor Sinks or Drains (Except Indirect Wastes from Above) x 4.0 = 0 GPM GALVANIZED SHEET METAL SHIELD. / — — — N0 SCALE Q I 4 0 Number of Miscellaneous Kettle Lines, etc. at Capacity or at Manufacturers 1 N. 113th WAY Rated Discharge = 0 GPM = 0 GPM AND TAPS. 1180 5 0 Dishwasher: Manufacturer's Peak Rate of Drain Flow GPM INSTALL DIELECTRIC FITTING BETWEEN FERROUS AND NON-FERROUS SCOT750ALE, AZ 85259 (Initial rate with full tank-Request from manufacturer) = 0 GPM MATERIALS. 5-A DRAIN PIPING (602) 277-7877 PH Dishwasher: Manufacturer's Rated Consumption per cycle: gallons x cycles per hour = gallons/hour / 60 = 0 GPM INDIRECT AND CONDENSATE DRAIN LINES SHALL BE TYPE 'M' HARD (602) 277-8288 FAX DRAWN 6 Specialized Equipment: 2 with discharge at: 2.0 gpm = 4 GPM COPPER WITH SOLDER JOINTS UNLESS SPECIFICALLY NOTED CLEANOUT PLUG 6-A TOTAL 22.9 GPM OTHERWISE. PROVIDE P-TRAP ON CONDENSATE LINES FROM A/C UNITS AND EVAPORATIVE COOLERS AND DRAIN TO APPROVED RECEPTACLE, AS SPECIFIED. APPLY TEFLON PIPE MAY SLOPE AT 1/8" PER FOOT MINIMUM. � - - - JOINT COMPOUND EXTEND AS 7 Loading Influences TO CLEANOUT DRAIN OR VENT Menu: Italian and Oriental - Total GPM (from 6-A) x 25% 0 GPM CONDENSATE DRAINS INSIDE THE BUILDING SHALL BE INSULATED WITH PLUG THREADS. Menu: 24 Hour Operation - Total GPM (from 6-A) x 25% 0 GPM CLOSED CELL AEROTUBE PIPE INSULATION, AS MANUFACTURED BY OWNER COLUMN OR MANVILLE. PROVIDE MINIMUM OF 1/2" THICKNESS TO PRECLUDE PARTITION AS Adjusted Total GPM -----23----- GPM CONDENSATION ACCUMULATION. CAULK W/ CLEAR SILICON WHERE CLEANOUT SHOWN ON - SEALANT AROUND PERIMETER TEE I CONCEALED FLOOR PLAN. PIPE RELIEF DRAIN FOR WATER HEATER TO OUTSIDE OR APPROVED FLASHING AND COUNTERFLASHING IN A WALL, CHASE RECEPTACLE AND TERMINATE A MINIMUM OF 6" ABOVE GROUND OR * I ��I �� I�I ' H OF VENT THRU ROOF IS BY --- OR PARTITION, USE CLEANOUT PROVIDE CLEANOUT WITH ADJUSTABLE CLEANOUT TOP WITH VARIATIONS SUITABLE APPROVED RECEPTACLE POINTING DOWNWARD. USE TYPE "M" HARD �OI V J_ ROOFING CONTRACTOR. MINIMUM 12" ABOVE ROOF FINISHED FLOOR PROVIDE SPECIFIED ACOVOR TEE, STRAIGHT FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR DRAWN COPPER WITH SOLDER JOINTS FOR DRAIN AND SLOPE AT 1/4" ���� ����tO, I COW I�� PLUMBING CONTRACTOR NORMALLY. EXTEND TOTEE WITH UNFINISHED FLOORS). CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. PER FOOT MINIMUM. I I� l.# ' TO COORDINATE INSTALL. HEIGHT OF PARAPET WHEN SCHEDULED. FERRULE, OR III I I ' I //�� //�� Q WITHIN 10' OF PARAPET. COMBINATION CLEANOUT PLUG AS SPECIFIED. SANITARY PIPING WEST �1"fE:STE:�� CH !L/ 70(o J HUB AT FLOOR WYE AND APPLY TEFLON JOINT COMPOUND EIGHTH BEND TO THE CLEANOUT PLUG THREADS FOR SANITARY WASTE AND VENT PIPING, USE STANDARD WEIGHT RISER LENGTH ROOF INSULATION AND/OR OTHER - ASPHALT COATED NO-HUB CAST IRON PIPE AND FITTINGS EXCEPT AS REQUIRED FITTINGS AS VENTS 2 1/2" AND SMALLER MAY USE GALVANIZED STEEL PIPE. II II ROOF DECK FOR DEPTH OF REQUIRED TO CONNECT NO-HUB CAST IRON AND FITTINGS TOGETHER WITH i FLOOR SINK HORIZONTAL PIPE. HAVE CLEANOUT STAINLESS STEEL SHIELD-CLAMP ASSEMBLIES ABOVE FLOOR. ALL PROJECT TITLE CORE DRILL ROOF OR ANCHOR PIPE TO ROOF OPENING WITHIN SAME SIZE AS FLOOR SLAB ON GRADE JOINTS BELOW FLOOR SHALL BE MG CAST IRON COUPLINGS OR HUSKY PROVIDE SLEEVE IF DECK WITH U-BOLT AROUND PROVIDE A LONG 2" OF FINISH SEWER UP TO 4" SERIES 4000 STAINLESS STEEL COUPLINGS. USE APPROVED PATTERN REQUIRED BY TYPE OF PIPE AND ANGLE IRON SWEEP ELBOW AT WALL SURFACE. MAXIMUM MEMBRANE CLAMP DRAINAGE TYPE CAST IRON FITTINGS ON ALL WASTE PIPING. ROOF DECK. PROVIDE WELDED OR SCREWED TO END OF LINE, OR FIRE STOP SEAL BETWEEN ROOF DECK OR JOIST. A COMBINATION WYE CONCRETE AS REQUIRED FOR LONG SWEEP ELBOW AT SLOPE ALL SOIL WASTE DRAIN PIPING AT A GRADIENT SLOPE OF NOT COLI) 8TO' `E GfRE,4MEfR"r PIPE AND SLEEVE OR DECK MINIMUM 12" BELOW ROOF AND EIGHTH BEND FLOOR SLAB DEPTH OF SEWER END OR TURN OF RUN LESS THAN 1/4" PER FOOT UNLESS SPECIFICALLY NOTED ON THECom) 5UITE Q 20 PROVIDE PIPE INCREASER _ IN RUN OF LINE. DRAWINGS. SLOPE OF LESS THAN 1/4" DUE TO SITE CONDITIONS MUST CLAM TERRACE ERQS `ACE - ` UITE ` IF/WHERE CODE REQUIRES A NO-HUB PIPE CONNECTORS DIRECTION SANITARY AND/OR COMBINATION WYE AND MINIMUM 3' VENT THRU ROOF ON CAST IRON PIPE OR STORM SEWER, SIZE EIGHTH BEND IN RUN, BE APPROVED BY THE ADMINISTRATIVE AUTHORITY. CA'r=W%4MEL, IN 46033 BELL AND SPIGOT IF PVC. , - _ _ _ OF FLOW PER PLAN REDUCING TYPE IF CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO P-TRAP. REFER TO SPECIFICATIONS AND SCHEDULES FOR MORE DIRECTION OF FLOW OF PIPE. OR INSTALLING NEW WASTE LINE. REQUIRED. ENTER TOP WHICH NEW WASTE LINES ARE TO BE CONNECTED BEFORE MAKING UP - � _ � REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR INFORMATION. PROVIDE WCO AT BASE OF RAIN-LEADER MINIMUM THREE FEET FROM PROPERTY LINE, OR TEN FEET HORIZONTAL DOWNSPOUTS AND SOIL STACKS. PROVIDE WCO WHERE SHOWN ON REFER TO SPECIFICATIONS AND SCHEDULE FOR MORE INFORMATION. CONDENSATE PIPING # STO�'E 1241 OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH - - PLAN, AND ON SANITARY WASTE BRANCHES LONGER THAN FIVE LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE AIR INTAKE, F ONE FOOT FROM ANY VERTICAL SURFACE. LOCATE VTR FEET NOT SERVED WITH I FLOOR CLEANOUT. LOCATE ABOVE GREATER THAN 45° AT 50' INTERVALS ON STRAIGHT RUNS AND/OR UNIT CONDENSATE DRAIN PIPING INSTALLED WITHIN THE BUILDING PROJECT NO: 04221 MINIMUM 18" FROM PARAPET, EXPANSION JOINT, EQUIPMENT CURB, ETC. - - FIXTURE FLOOD RIM WITHIN FOUR FEET OF FLOOR. CONSULT OFFSET IN CEILING SPACE WHERE REQUIRED TO MEET THESE CONDITIONS. LOCAL CODES AND OFFICIALS FOR OTHER WCO REQUIREMENTS. WHERE SHOWN ON PLANS AND RISERS. PROVIDE BACKFILL PER SHALL BE TYPE "M" FOR 1" AND SMALLER OR "DWV" FOR 1-1/4" AND c, y+,�,�. ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUT WHERE THERE LARGER HARD TEMPER COPPER TUBE WITH WROUGHT COPPER IS 18" CLEAR AROUND, FOR ACCESSIBILITY. CONSULT LOCAL DRAINAGE PATTERN FITTINGS AND SOLDERED CONNECTIONS MADE UP FILE NAME: 0450000591P2Awg ae` 41ST; r� ° c10 6 VENT THRU ROOF rJ FL R SINK DETAIL q)YN ALL C LEAN 0 UT CODES AND OFFICIALS FOR OTHER REQUIREMENTS. WITH 95/5 SOLDER. INSTALL CLEANOUTS AT ALL ELBOWS AND TURNSGREATER THAN 45 DEGREES. UNIT CONDENSATE DRAIN PIPING C092f1463N0 SCALE NO SCALE O SCALE INSTALLED OUTSIDE THE BUILDING AND ABOVE GROUND SHALL BE DATE: x/2/04 t L FLOOR R C LEAN 0 UT DETAIL SCHEDULE 40 PVC, WHERE ALLOWED BY CODE. TERMINATE INTERIOR o^. 'aATC' O�- a NO SCALE PIPING IN BUILDING AT MOP SINK AS SHOWN ON DRAWINGS. (NOTE: DRILL HOLE IN SIDE PROVIDE 1" THICK ELASTOMERIC INSULATION DRAWN BY: CDS PVC PIPING IS NOT ALLOWED IN CEILING RETURN AIR PLENUMS). , N OF BOX AND OVER HEAT TRACING ON CONDENSATE DRAIN COLD WATER SUPPLY HOT WATER SUPPLY .f o PROVIDE GROMMET INSTALL ELECTRIC HEATING CABLE FOR TO FIXTURES AS TO WATER HEATER a OR SLEEVE WITH CONDENSATE DRAINS LOCATED IN FREEZERS. SHOWN ON PLANS --��� CHECK VALVE REVIEWED BY: KLB J i t ' SILICONE SEAL HEATING CABLE IS PROVIDED BY OTHERS. AROUND PIPE INSTALL ASME —COLD WATER TO EXPANSION REV. DESCRIPTION DATE • � - � C1 TANK AS SHOWN ON PLANS PENETRATION TO _ -_ _.._ -__ _ TEMPERATURE AND _ 3MAKE IT WATERTIGHT. DX COIL PRESSURE RELIEF VALVE AUTOMATIC VACUUM RELIEF a 180 DEGREE ELBOW 2" VENT IN WALL 2" VENT IN WALL FURNISHED WITH WATER BEHIND BACKSPLASH CO - CD HEATER VALVE (WHEN REQUIRED) INSTALL DRAIN 0 6" ABOVE RIM CO LINE BEHIND PROVIDE A HARD COPPER RELIEF PROVIDE TRAP WITH 2" SHUT-OFF VALVE 1 SHELVING IN PIPE HANGER NEXT TO ELBOW FROM CW SUPPLY TYPICAL VALVE DISCHARGE LINE FULL SIZE PROVIDE CLEANOUT ( ) In TRAP SEAL AT BOTTOM WALK-IN BOX. TO HEATER, NO OF VALVE OUTLET a GREASE TRAP OF RISER FLAT AGAINST IN TURNS AND ENDS ��-- PROVIDE PIPE UNION, COORDINATE. PIPE UNION: DIELECTRIC INTERVENING VALVES REFERENCE OF PIPE. DIELECTRIC IF REQUIRED 6" WATERTIGHT PAN UNDER s AIR INTAKE SPECIFICATIONS WALL DISCHARGE OVER IN FIELD IF REQUIRED FOR FOR DISSIMILAR METALS 0 WATER HEATER WITH DRAIN PIPE CITY SUBMITTAL x/2/04 o AND FLOOR DRAIN WITH AIR GAP o DISSIMILAR METALS z V SCHEDULES OF TWICE PIPE DAIMETER MAKE CONNECTION (TYPICAL) SHEET TITLE CLEANOUTS IN I MINIMUM 2". TO COIL AS REQUIRED. WELDED STEEL EXPANSION GENERAL CONTRACTOR TO m TANK WITH POLYPROPYLENE ELECTRIC WATER HEATER; ENDS OF PIPE CLEAN- CLEANOUT PROVIDE WATER HEATER ANCHOR RISER TO BOX EXTERIOR WALL. REFER TO SPECIFICATIONS U � OUT 2 GW f LINING, FDA APPROVED FOR SUPPORT. REFERENCE O O DOMESTIC WATER SERVICE AND SCHEDULE ARCHITECTURAL PLAN. FLOOR SHUTOFF VALVE FLOOR SINK FLOOR WALK-IN COOLER OR FREEZER BOX. 1 BUTYL DIAPHRAGM DRAIN VALVE BY WATER PLUMBING RISER cc m i HEATER MANUFACTURER _ ROUTE RELIEF VALVE DISCHARGE FLOW CONTROL FITTING LINE AND DRAIN PAN LINE TO AND DETAILS FLOOR SINK _ _ _ _ __._ _ _ FILL TANK WITH AIR CODE APPROVED RECEPTOR AND PRESSURE TO MATCH DISCHARGE WITH 6" AIR GAP. GW SEE FLOOR PLAN FOR FLOOR DRAIN LOCATION. WATER PRESSURE, PIPING ARRANGEMENT SHOWN IN SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. THEN OPEN VALVE In INSTALL PIPE AS HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX WITH SUPPORTS AT REFER TO SPECIFICATIONS, SCHEDULES AND NOTES FOR MORE INFORMATION. PIPING C) W MAXIMUM SIX FEET CENTERS. USE TYPE "M" HARD COPPER TUBE AND FITTINGS WITH PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT ARRANGEMENT SHOWN IS SCHEMATIC. VERIFY ALL CONNECTION SIZES AND LOCATIONS NOTE: SHEET NO. FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. o LEAD-FREE SOLDER JOINTS SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PER MANUFACTURERS REQUIREMENTS. ADJUST TO SUIT FIELD CONDITIONS. REFER TO z PROVIDE CHROMATONE PAINT ON PIPE EXTERIOR TO BOX. INSTALL PIPE MINIMUM 3/4-PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. FLOOR PLANS FOR PIPE SIZES. PROVIDE SEISMIC STRAP OR BRACING IF/AS REQUIRED EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS FROM BOX WALL, AND 6" FROM FLOOR. DO NOT PASS ACROSS OPENING OF DOORWAY. BY LOCAL AUTHORITIES. PROVIDE HEAT TRAP AND AUTOMATIC VACUUM RELIEF VALVE AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. FIELD VERIFY ALL m ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. WHEN REQUIRED BY LOCAL AUTHORITIES. EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY UTILITY SINK AND GREASE TRAP WALK - I N B 0 X CONDENSATE DRAIN COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES o 0 NO SCALE NO SCALE 8 S MALL EXPANSION TANK ELECTRIC WATER HEATER AND EXISTING CONDITIONS. . o NO SCALE NO SCALE U Ln 0 0 0 Ln 0 z m E m U m 0 0 U �ANELBOARD "CSC2" PANELBOARD "CSC" 14 1 ELECTRICAL LIGHTING FLOOR PLAN 1/4"= 1 '0" N PANELBOARD "CSC2" PANELBOARD "CSC" 13 (PART.) 5 9 CSC2-25 T CSC2-20 17 CSC X2 ❑ 37 (PART) TRANSFORMER "CSC" CSC2-34 t39 .. CSC2-23 2 ELECTRICAL POWER 1/4"= 1'0" N ELECTRICAL SYMBOLS LEGEND WIRING DEVICES & OUTLETS ra SINGLE POLE WALL SWITCH (NO LETTER DESIGNATION) SWITCH LETTER DESIGNATIONS AS FOLLOWS: FILE NAME: 0450000591EI.dwg a = SWITCH "a" DATE: DUPLEX RECEPTACLE — NEMA 5-20R ° 4—PLEX RECEPTACLE — NEMA 5-20R RECEPTACLE MOUNTED ABOVE COUNTER OR BACKSPLASH DRAWN BY: CEILING MOUNTED RECEPTACLE HEAVY DUTY TYPE RECEPTACLE ISOLATED GROUND (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) GFCI RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: C = CLOCK HANGER TYPE IG = ISOLATED GROUND DESCRIPTION E = EMERGENCY POWER GFCI = GROUND FAULT RECEPTACLE S = SWITCHED WP = WEATHERPROOF Mo V TELEPHONE OUTLET — FLOOR OR WALL MOUNTED In V DATA OUTLET — FLOOR OR WALL MOUNTED ® v TELE/DATA OUTLET — FLOOR OR WALL MOUNTED * TELE/DATA OUTLET SHALL BE MOUNTED AT SAME ELEVATION AS ADJACENT POWER RECEPTACLE UNLESS NOTED OTHERWISE. 0 MULTI—SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER OUTLETS A A = TYPE A, SEE SCHEDULE ❑J 0 JUNCTION BOX CIRCUITING & WIRING 7 5 3 HOMERUN TO PANELBOARD, ARROWS INDICATE NUMBER OF CIRCUITS, P1 HASH MARKS INDICATE NUMBER OF CONDUCTORS; INFORMATION AT ARROWS OR ARE CIRCUIT NUMBERS AND PANELBOARD. P 1-3,5,7 GROUND WIRE IN CONDUIT ("GREEN—WIRE" GROUNDING) }� ISOLATED GROUND WIRE IN CONDUIT (GREEN WITH YELLOW STRIPE) CONDUIT CONCEALED CONDUIT IN/UNDER FLOOR/GROUND CONSTRUCTION POWER EQUIPMENT & DEVICES = ELECTRICAL PANELBOARD (SURFACE OR FLUSH MOUNT) o Q TERMINAL CABINET (SURFACE OR FLUSH MOUNT), TYPE AS NOTED ELECTRICAL DISTRIBUTION PANELBOARD 0 SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD PLYWOOD TERMINAL BOARD FOR TELEPHONE SYSTEM U.N.O. SIZE AS NOTED 60 3/35 LED DISCONNECT SWITCH — "60/3/35" DENOTES AMPERES/POLE/FUSE NF= NON—FUSED CB= CIRCUIT BREAKER (35/3/CB) MOTOR TS TIME SWITCH FSSMOKE DETECTOR IN DUCT: RD—RETURN DUCT RD SD—SUPPLY DUCT LIGHTING FLUORESCENT LIGHT FIXTURE: A a a = SWITCHED TO SWITCH "a" 0 a A = LIGHT FIXTURE TYPE "A" 0 LIGHT FIXTURE — CEILING / WALL MOUNTED (SEE LIGHT FIXTURE SCHEDULE) ® EXIT SIGN — CEILING / WALL MOUNTED, ARROWS AS INDICATED (SEE LIGHT FIXTURE SCHEDULE) p�4 EMERGENCY BATTERY PACK LIGHT FIXTURE — CEILING / WALL MOUNTED (SEE LIGHT FIXTURE SCHEDULE) 4V COMBINATION EMERGENCY BATTERY PACK LIGHT FIXTURE/EXIT SIGN — CEILING / WALL MOUNTED (SEE LIGHT FIXTURE SCHEDULE) 0 WALL WASH LIGHT FIXTURE — CEILING MOUNTED (SEE LIGHT FIXTURE SCHEDULE) AUDIO / VIDEO ABBREVIATIONS OS CEILING MOUNTED SPEAKER WP — WEATHERPROOF GFCI — GROUND FAULT CIRCUIT INTERRUPTER TYP — TYPICAL AFF — ABOVE FINISHED FLOOR REF — REFERENCE PART — PARTIAL CIRCUIT AFC — AVAILABLE FAULT CURRENT GENERAL NOTES: 1, REFER TO EQUIPMENT SCHEDULE ON ARCHITECTURAL PLANS FOR ALL ELECTRICAL EQUIPMENT LOCATIONS AND EXACT DEVICE MOUNTING HEIGHTS PRIOR TO ROUGH IN. 2. REFER TO ARCHITECTURAL DRAWING, SHEET A-1 FOR OVERALL KEY PLAN. 3. PROVIDE TYPED PANELBOARD SCHEDULES. 4. REFER TO ARCHITECTURAL SHEETS FOR TAG DESCRIPTIONS AND ADDITIONAL INFORMATION, INCLUDING MOUNTING HEIGHTS. KEYED NOTES: ❑1 VERIFY LOCATION OF EXISTING SIGNAGE JUNCTION BOX AND EXTEND CONDUIT TO TIMESWITCH AS REQUIRED. ❑2 PROVIDE STRUCTURAL SUPPORT PER NEC 422.18 FOR CEILING FAN. JUNCTION BOX SHALL BE LISTED FOR CEILING FAN USE. ❑3 PROVIDE SWITCH BANK CONSISTING OF SWITCHES UNDER A COMMON FACEPLATE FOR CONTROL OF LIGHTING. ® PROVIDE A 4"X4" OUTLET BOX AT 18" AFF WITH A 3/4" CONDUIT STUBBED INTO ACCESSIBLE CEILING WITH PULL CORD. TYPICAL FOR TELEPHONE/DATA OUTLETS. ❑5 TIMESWITCHES FOR TENANT SIGNAGE AND EXHAUST FAN TO BE LOCATED ABOVE PANELBOARDS. © INSTALL SPEAKER BACK BOX FURNISHED BY OWNER. ❑7 3/4" CONDUIT TO MUSAK HEAD—END. ® DISCONNECT PROVIDED WITH EQUIPMENT. 0 PROVIDE 1" CONDUIT BACK TO LANDLORD'S TELEPHONE BACKBOARD FOR TENANT'S TELEPHONE CABLE. COORDINATE ROUTING WITH LANDLORD. PROVIDE 1' -6"x4' -0"x0'-3/4" FIRE RATED PLYWOOD ON WALL APPROXIMATELY 3'-0" AFF FOR TELEPHONE EQUIPMENT. 10 INSTALL LIGHT FIXTURE INSIDE FREEZER/COOLER. 11 WP/GFCI RECEPTACLE ON ROOF WITH FULLY ENCLOSED, WHILE—IN—USE COVERPLATE. 12 INSTALL SHOW WINDOW RECEPTACLE IN CEILING TILE OR ABOVE WINDOW. BLACK RECEPTACLE WITH BLACK COVERPLATE. 13 JUNCTION BOX FOR FUTURE TENANT SIGNAGE. PROVIDE 3/4" EMPTY CONDUIT WITH PULL WIRE BACK TO PANELBOARD SPECIFIED. 14 REMOTE WEATHERPROOF HEADS ON BUILDING EXTERIOR. INSTALL AT APPROXIMATELY 8'-0" ABOVE GRADE. 15 JUNCTION BOX FOR T—STAT AT 48" AFF. COORDINATE LOCATION AND MOUNTING HEIGHT WITH DIVISION 15. 16 PROVIDE SMOKE DETECTORS IN SUPPLY AND RETURN AIR DUCTS. PROVIDE JUNCTION BOX FOR MOTORIZED DAMPERS, SMOKE DETECTORS AND AUDIBLE/VISUAL ANNUNCIATING DEVICE AT CEILING. CIRCUIT AS SHOWN. SEE MECHANICAL PLANS FOR DESCRIPTION OF OPERATION. 17 TRANSFORMER "CSC" SHALL BE SUSPENDED FROM STRUCTURE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS, AND SHALL BE MOUNTED BELOW THE CEILING AND ABOVE 6'-6" AFF. REFER TO DETAIL 3 ON SHEET E-1 FOR ADDITIONAL INFORMATION. NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS—BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. cohl) 8 G n E A IVI c m a xx i 2944 N. 44TH STREET, SUITE 150 PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ENGINEER: mo u9j HENDERSON ENGINEERS INCORPORATED 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENCINEERS.COM 0450000591 ARCHITECT: DAVID A. MOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON 5ALATICH -1424 WYN5T0NE COURT WEST CHESTER, OSI 0r20(o9 PROJECT TITLE COLD STONE CREAMERY CLAY TERRACE - SUITE 528 CARMEL, IN 46033 STORE # 1241 PROJECT NO: 04221 ra n FILE NAME: 0450000591EI.dwg pe DATE: 1/2/04 ° DRAWN BY: ARC O REVIEWED BY: RAN REV. DESCRIPTION DATE A CITY SUBMITTAL 1/2/04 SHEET TITLE ELECTRICAL LIGHTING/POWER PLANS & SYMBOLS LEGEND SHEET N0. E-1 11 0 ELECTRICAL SPECIFICATIONS 1.) CONDUIT LAYOUTS SHOWN ON THE PLANS ARE DIAGRAMMATIC, NOT INDICATING THE ROUTING REQUIRED. THE CONTRACTOR SHALL ROUTE CONDUITS AS REQUIRED BY THE CONDITIONS OF INSTALLATION. 2.) ALL EQUIPMENT PROVIDED BY THE ELECTRICAL CONTRACTOR SHALL BE LISTED AND LABELED BY A NATIONALLY -RECOGNIZED TESTING AGENCY, ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION, FOR THE CONDITIONS OF INSTALLATION. 3.) DEVICE LOCATIONS SHOWN ON THE DRAWINGS ARE APPROXIMATE. EXACT DEVICE LOCATIONS SHALL BE AS INDICATED ON THE ARCHITECTURAL PLANS OR AS DIMENSIONED. IF NOT SHOWN ON THE ARCHITECTURAL PLANS OR DIMENSIONED ON THE ELECTRICAL PLANS, VERIFY EXACT LOCATION WITH THE ARCHITECT PRIOR TO ROUGH -IN. 4.) PLANS INDICATE THE NUMBER OF PHASE, NEUTRAL, AND GROUND CONDUCTORS WHERE MORE THAN THREE CONDUCTORS ARE TO BE INSTALLED IN A CONDUIT (THREE OR LESS CONDUCTORS ARE NOT SHOWN). ADDITIONAL CONDUCTORS REQUIRED FOR CONTROL SHALL BE INCLUDED EVEN IF NOT EXPLICITLY SHOWN. 5•) WHERE SIZE IS NOT SHOWN ON THE DRAWINGS, CIRCUITS SHALL CONSIST OF #12 PHASE AND GROUNDED (NEUTRAL CONDUCTORS) AND A #12 CU GROUND IN 3/4" CONDUIT. 6.) UNLESS SPECIFICALLY NOTED OTHERWISE, THE ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO ALL UTILIZATION EQUIPMENT SHOWN ON THE DRAWINGS. VERIFY THE TYPE OF FINAL CONNECTION AND PROVIDE APPROPRIATE WIRING METHOD. 7.) THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL, PLUMBING AND GENERAL CONTRACTORS, PRIOR TO ORDERING OR INSTALLATION OF ANY EQUIPMENT, TO VERIFY MECHANICAL AND PLUMBING EQUIPMENT REQUIREMENTS ARE PROVIDED IN THE ELECTRICAL DESIGN. THE CONTRACTOR WILL NOT BE COMPENSATED FOR COSTS ASSOCIATED WITH CHANGING THE ELECTRICAL SYSTEMS TO MATCH UTILIZATION EQUIPMENT, EVEN IF THE ELECTRICAL WORK IS INSTALLED PER THE ELECTRICAL DRAWINGS. 8.) THE ELECTRICAL CONTRACTOR SHALL REVIEW THE MECHANICAL PLANS, PRIOR TO BID, AND DETERMINE THE LOCATION OF SMOKE OR FIRE/SMOKE DAMPERS, IF ANY. UNLESS OTHERWISE NOTED ON THE ELECTRICAL PLANS, EACH SMOKE OR FIRE/SMOKE DAMPER SHALL BE CONNECTED TO THE NEAREST RECEPTACLE CIRCUIT, NOT TO EXCEED THREE (3) DAMPERS ADDED TO ANY CIRCUIT. INCLUDE IN THE BASE BID BID ONE (1) DUCT SMOKE DETECTOR PER SMOKE OR FIRE/SMOKE DAMPER SHOWN ON THE MECHANICAL PLANS. 9.) UNLESS NOTED OTHERWISE, EACH DAMPER DUCT SMOKE DETECTOR SHALL BE RATED 24VAC AND SHALL BE CONNECTED TO THE FIRE ALARM PANEL (IF ANY) ON A SEPARATE ZONE. 10.)SMOKE OR FIRE/SMOKE DAMPERS SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM (IF ANY) AND SHALL BE CONTROLLED BY THE FIRE ALARM CONTROL PANEL (IF ANY). 11.)THE ELECTRICAL CONTRACTOR SHALL REVIEW THE PLANS, PRIOR TO BID, TO DETERMINE THE NUMBER AND LOCATION OF HVAC UNITS. THE ELECTRICAL CONTRACTOR SHALL INCLUDE, IN THE BASE BID, DUCT SMOKE DETECTORS FOR EACH UNIT. THE DETECTORS SHALL BE RATED 24VAC WITH INTEGRAL TRANSFORMATION FOR CONNECTION TO THE POWER SUPPLY OF THE UNIT IT IS TO CONTROL (VERIFY VOLTAGE). PROVIDE THE DETECTORS TO THE MECHANICAL CONTRACTOR FOR INSTALLATION IN THE DUCT. CONNECT EACH DETECTOR TO SHUT DOWN IT'S ASSOCIATED UNIT AND TO REPORT STATUS TO THE FIRE ALARM CONTROL PANEL (IF ANY) ON A SEPARATE ZONE. 12.)SOME CONDUCTOR SIZES ARE BASED ON THE USE OF 75 DEGREE C CONDUCTOR RATINGS. THE CONTRACTOR SHALL VERIFY, PRIOR TO INSTALLATION OF CONDUCTORS OR CONDUIT FEEDING ANY EQUIPMENT, THAT ALL ELECTRICAL EQUIPMENT IS RATED FOR USE WITH 75 DEGREE C WIRING. IF ANY EQUIPMENT IS RATED FOR USE WITH LESS THAN 75 DEGREE C CONDUCTORS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY FOR EVALUATION/CORRECTION. 13.)UNLESS SPECIFICALLY NOTED OTHERWISE, SYSTEMS PROVIDED OR INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE COMPLETE AND FULLY -FUNCTIONING AFTER INSTALLATION. COMPONENTS NOT SHOWN, BUT REQUIRED FOR THE PROPER OPERATION OF THE EQUIPMENT OR SYSTEM, SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE PROJECT. 14.)THE CONTRACTOR SHALL PERFORM ALL ACCEPTANCE TESTS REQUIRED OR RECOMMENDED BY EQUIPMENT MANUFACTURERS. i. REMOVE ALL ACCESSIBLE ABANDONED WIRING ABOVE CEILING. j. FURNISH AND INSTALL FIRE FUEL SHUT-OFF SERVICES INCLUDING GAS SUPPLY VALVE. k. FURNISH AND INSTALL ALL CONNECTIONS INCLUDING POWER AND CONTROL WIRING TO ALL WALK-IN BOXES AND TO THE REMOTE COMPRESSORS. REFER TO KITCHEN CONSULTANT DRAWINGS FOR SPECIFIC REQUIREMENTS. ALL RECEPTACLES MOUNTED WITHIN 6'-0" OF SINK, , ALL REST ROOMS AND EXTERIOR MOUNTED SHALL BE GFCI TYPE. m. ALL EXTERIOR DEVICES SHALL BE WEATHERPROOF. n. FOR EACH EQUIPMENT ITEM NOT PROVIDED WITH CORD AND PLUG CONNECTION, THE CONTRACTOR SHALL VERIFY THE EQUIPMENT CONTAINS AN INTEGRAL UNIT SWITCH COMPLYING WITH NEC, 422.34. IF THE EQUIPMENT HAS NO UNIT SWITCH, PROVIDE A LOCK -OFF DEVICE AT THE BRANCH CIRCUIT BREAKER FEEDING THE EQUIPMENT. 28.) UTILITY COORDINATION a. AS REQUIRED, THE CONTRACTOR SHALL SUBMIT A COMPLETE SET OF DRAWINGS TO ELECTRICAL AND TELCO UTILITIES WITHIN ONE WEEK OF NOTICE TO PROCEED. b. WHEN REQUIRED, THE CONTRACTOR SHALL NOT TRENCH OR INSTALL CONDUITS (ON THE UTILITY OR LOAD SIDE) TO THE SERVICE ENTRANCE DEVICE, THE UTILITY TRANSFORMER (PRIMARY OR SECONDARY), OR TO THE UTILITY CONNECTION POINT BEFORE RECEIVING A FINAL DESIGN FROM THE UTILITY. c. WHEN REQUIRED, THE CONTRACTOR SHALL NOT INSTALL EQUIPMENT PADS FOR THE SERVICE ENTRANCE DEVICE OR ANY UTILITY EQUIPMENT (TRANSFORMERS, SWITCHING CABINETS, ETC) PRIOR TO RECEIPT OF FINAL PLANS FROM THE UTILITY OR LANDLORD. d. WHEN REQUIRED, THE CONTRACTOR SHALL NOT BE COMPENSATED FOR ADDITIONAL WORK REQUIRED TO MEET THE REQUIREMENTS OF THE UTILITY WHICH IS THE RESULT OF PROCEEDING PRIOR TO RECEIPT OF A FINAL UTILITY DESIGN. 15.)ALL 15/20A, 120V RECEPTACLES INSTALLED IN WORK AREA (KITCHEN) SHALL BE GFCI PROTECTED. 16.)UNLESS OTHERWISE NOTED, ALL EQUIPMENT DISCONNECTS SHALL BE NEMA TYPE 3R, FUSIBLE, 30A, 3 POLE. FUSE PER EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS. 17.)DEVICE BOXES SHOWN BACK-TO-BACK SHALL BE OFFSET A MINIMUM OF TWELVE (12) INCHES TO REDUCE SOUND TRANSMISSION BETWEEN ROOMS. 18.)ALL PENETRATIONS IN WALLS SHALL BE SEALED WITH FLEXIBLE ACOUSTIC CAULKING. CAULKING SHALL BE APPLIED AROUND OUTLET BOXES TO PROVIDE A COMPLETE SEAL BETWEEN THE BOX AND THE WALL. 19.)PRIOR TO TRENCHING IN ANY AREA, THE CONTRACTOR SHALL CONTACT ELECTRICAL, COMMUNICATIONS/DATA, CABLE TV, GAS, AND WATER UTILITY PROVIDERS (BLUE STAKE) AND HAVE ALL UTILITIES IN THE AREA IDENTIFIED. IN ADDITION, THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A SUBCONTRACTOR SPECIALIZING IN THE LOCATION OF UNDERGROUND STRUCTURES TO IDENTIFY ANY OBSTACLES IN THE PATH OF TRENCHING (PRIOR TO COMMENCING WORK). DAMAGE TO ANY UNDERGROUND STRUCTURES SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE PROJECT. 20.)LIGHT FIXTURES IN SUSPENDED CEILINGS SHALL BE INSTALLED IN COMPLIANCE WITH LOCAL BUILDING CODE, REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: a. LIGHT FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. b. INSTALL (OR VERIFY THE EXISTENCE OF, A #12 GAGE HANGER WIRE WITHIN 3" OF EACH CORNER OF THE LIGHT FIXTURE. c. INSTALL TWO #12 GAGE WIRES FROM EACH FIXTURE TO THE STRUCTURE ABOVE, CONNECTED TO OPPOSITE CORNERS OF THE FIXTURE. FOR FIXTURES WEIGHING LESS THAN 56 POUNDS, THESE WIRES MAY BE SLACK. FOR FIXTURES WEIGHING 56 POUNDS OR MORE, THESE WIRES SHALL BE TIGHTENED TO CARRY THE FULL WEIGHT OF THE FIXTURE. d. PENDANT -HUNG FIXTURES SHALL BE SUPPORTED FROM THE STRUCTURE ABOVE WITH A #9 GAGE WIRE OR OTHER APPROVED SUPPORT METHOD WHICH DOES NOT DEPEND ON THE CEILING SUPPORT SYSTEM. 21.) LIGHT FIXTURES MOUNTED IN CEILINGS WHICH FORM AN AIR -HANDLING SPACE (PLENUM) SHALL BE SPECIFICALLY LISTED FOR SUCH INSTALLATION. 22.) LIGHT FIXTURES MOUNTED IN FIRE -RATED CEILINGS SHALL BE SPECIFICALLY LISTED TO MAINTAIN THE FIRE RATING. 23.) WHERE THE PLANS INDICATE A LIGHT FIXTURE IS TO BE PROVIDED WITH SPECIAL FEATURES/SWITCHING (DIMMING, EMERGENCY, THREE-LEVEL, ETC) THE CONTRACTOR SHALL PROVIDE THESE FIXTURES WITH THE APPROPRIATE BALLASTING TO ACCOMODATE THE SPECIAL FEATURE. THE CONTRACTOR SHALL PROVIDE THE FIXTURES AS INDICATED IN THE LIGHT FIXTURE SCHEDULE, WITH MODIFICATIONS AS REQUIRED BY PLAN NOTES. 24.)WHERE A MANUAL MOTOR STARTER IS SHOWN ON THE PLANS, THE CONTRACTOR SHALL VERIFY THE DEVICE PROVIDED IS LABELED "SUITABLE AS MOTOR DISCONNECT". 25.)WHERE A COMBINATION CONTROLLER IS SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL VERIFY THE DEVICE PROVIDED IS LABELED "SUITABLE AS MOTOR DISCONNECT" AND IS LISTED AS A BRANCH CIRCUIT OVERLOAD AND SHORT-CIRCUIT PROTECTIVE DEVICE. 26.) DEMOLITION NOTES: a. FOR EQUIPMENT BEING REMOVED AND REPLACED, THE CONTRACTOR SHALL DE -ENERGIZE THE EQUIPMENT AND MAKE IT SAFE PRIOR TO REMOVAL. COMPLY WITH OSHA REQUIREMENTS FOR LOCKING -OUT AND TAGGING EQUIPMENT TO PREVENT INADVERTENT RE -ENERGIZING. b. WHERE EQUIPMENT IS BEING REMOVED, BUT NOT REPLACED, REMOVE THE CONDUCTORS FEEDING THE EQUIPMENT BACK TO THE POINT WHERE THEY RECEIVE POWER (CIRCUIT BREAKER OR BRANCH CIRCUIT TAP). REMOVE ACCESSIBLE CONDUITS. ABANDON IN-PLACE INACCESSIBLE CONDUITS. AFTER REMOVAL OF EQUIPMENT, REPAIR ANY OPENING LEFT TO MATCH SURROUNDING WALLS, CEILINGS, OR FLOORS TO THE OWNER'S SATISFACTION. c. COORDINATE WITH THE OTHER TRADES, PRIOR TO BID, AND INCLUDE IN THE BASE BID THE ELECTRICAL DISCONNECTION OF ANY EQUIPMENT BEING DEMOLISHED, EVEN IF NOT EXPLICITLY UNLESS NOTED OTHERWISE, REMOVE ALL DEMOLISHED EQUIPMENT FROM THE PROPERTY AND IDENTIFIED IN THE ELECTRICAL PLANS. d. DISPOSE OF IT PROPERLY (IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL ENVIRONMENTAL REGULATIONS). FEES ASSOCIATED WITH DISPOSAL SHALL BE INCLUDED IN THE CONTRACTOR'S BASE BID. 27.) NOTES A THRU L BELOW APPLY TO ALL KITCHEN AREAS. a. FINAL CONNECTION TO ALL KITCHEN EQUIPMENT SHALL BE MADE WITH U.L. LISTED "SEAL-TITE" FLEXIBLE CONDUIT. b. THE ELECTRICAL CONTRACTOR SHALL MAKE FINAL ELECTRICAL CONNECTIONS TO ALL KITCHEN FOOD SERVICE AND RELATED EQUIPMENT. EX c• THIS SYMBOL IDENTIFIES FOOD SERVICE EQUIPMENT AS IT IS SHOWN ON THE PLANS. SEE ARCHITECTRUAL DRAWINGS FOR ADDITIONAL INFORMATION. d. THE ELECTRICAL CONTRACTOR SHALL VERIFY ROUGH -IN REQUIREMENTS, LOCATIONS, MOUNTING HEIGHTS, VOLTAGE, PHASE, AMPS, HP, KW, ETC. FOR ALL FOOD SERVICE EQUIPMENT PRIOR TO ROUGH -IN. e. PROVIDE SEAL-OFF'S FOR ALL CONDUITS ENTERING OR LEAVING WALK-IN BOXES. f. KITCHEN HOOD EXHAUST, MAKE-UP AIR UNIT AND GAS SOLENOID VALVE SHALL BE INTERLOCKED TOGETHER. WHEN MAKE-UP AIR UNIT IS ON, EXHAUST FAN, AND GAS SOLENOID VALVE IS ON. WHEN MAKE-UP AIR UNIT IS OFF, EXHAUST FAN AND GAS SOLENOID VALVE IS OFF. PROVIDE REQUIRED RELAYS. g. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE ROUGH -IN REQUIREMENTS, LOCATIONS, ORIENTATION, VOLTAGE PHASE, HP, KW, ETC. FOR ALL HVAC AND PLUMBING EQUIPMENT PRIOR TO ROUGH -IN. h. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL DISCONNECT SWITCHES, INTERLOCKS, CONDUIT, WIRING AND INSTALLATION AS SPECIFICALLY OUTLINED WITHIN THE DRAWINGS. LCk LCk TS 29.) NOT USED. 30.) PROVIDE TIME SWITCHES WITH NUMBER AND TYPES OF CONTACTS, SEQUENCE, AND VOLTAGE AS NOTED ON DRAWINGS OR AS REQUIRED BASED ON THE TIME SWITCH FUNCTION AND THE NUMBER OF BRANCH CIRCUITS CONTROLLED. TIME SWITCHES SHALL BE ELECTRONIC DIGITAL TYPE WITH MANUAL BYPASS SWITCH, AND NEMA ENCLOSURE SUITABLE FOR THE ENVIRONMENT INSTALLED. TIME SWITCHES SHALL BE AS MANUFACTURED BY INTERMATIC, PARAGON OR TORK. 31.) FURNISH AND INSTALL SQUARE D TYPE NQOD LIGHTING/POWER PANELBOARDS, OR EQUIVALENT SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC, AS SCHEDULED AND LOCATED ON THE DRAWINGS. THE PANELBOARD SHALL BE COMPLETE WITH THERMAL MAGNETIC MOLDED CASE CIRCUIT BREAKERS OF THE BOLT -ON TYPE ASSEMBLED IN A FINISHED CABINET. ALL 2 AND 3 POLE BREAKERS SHALL BE COMMON TRIP. BREAKERS USED AS SWITCHES FOR 120 VOLT LIGHTING CIRCUITS SHALL BE APPROVED FOR THE PURPOSE MARKED "SWD". EACH PANELBOARD SHALL CONTAIN A TYPEWRITTEN CARD DIRECTORY INDICATING EXACTLY WHAT EACH CIRCUIT CONTROLS. PLUG-IN TYPE BREAKERS WILL NOT BE ACCEPTABLE. BREAKERS USED FOR THE PROTECTION OF HVAC EQUIPMENT SHALL BE HACR TYPE. PANELBOARD: CSC FAULT CURRENT: <10,000a EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: 10,000A FULLY RATED MAIN SIZE/TYPE: MLO SERVES: COLD STONE CREAMERY VOLTS/PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE SECTION(S): 1 LOCATION: WORK AREA CKT N0. DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS PHASE DESCRIPTION CKT N0. A B C A B C 1 WORK AREA/RR/LOBBY/EM LIGHTS 2,440 12 20 1 3 30 10 6,010 WATER HEATER 2 3 LOBBY/SERVICE/EM LIGHTS 1,006 12 20 1 3,462 4 5 SPARE 2 7 20 1 3,462 6 7 SPARE WALK-IN COOLER 874 20 1 3 20 12 1,911 CU -1 8 9 SPARE REACH IN 2 DOOR FREEZER 1,236 20 1 1,911 10 11 SPACE ONLY 10 30 2 1 1,911 12 13 SPACE ONLY 2,080 1 20 1 3 20 12 _ 3,379 CU -2 14 15 SPACE ONLY 20 12 360 TELEPHONE BOARD RECEPT 20 1 3,379 16 17 SPACE ONLY 1 1 20 1 3,379 18 19 SPACE ONLY 12 20 1 1 1 12 25 TIMESWITCHES SPACE ONLY 20 21 SPACE ONLY 1 20 1 12 1 1_ DUCT DETECTOR 180 12 SPACE ONLY 22 23 SPACE ONLY 12 708 REFRIGERATED DISPLAY CASE 28 29 1 1 10 20 1 SPACE ONLY 24 25 SPACE ONLY 31 SHOW WINDOW RECEPT 360 1 1 1 33 MUSAK RECEPT SPACE ONLY 26 27 SPACE ONLY 1 20 12 1 1 COMPUTER RECEPT 360 12 SPACE ONLY 28 29 SPACE ONLY 12 37 CONE IRON 1 1_ 20 1 1 SPACE ONLY 30 31 FCU -1 8,969 6 45 3 1 1 20 12 SPACE ONLY 32 33 8,969 1 15 1 1 SPACE ONLY 34 35 8,969 1 DF SPACE ONLY 36 37 FCU -2 5,346 10 25 3 3 60 OL 16,588 _ PANELBOARD CSC2 TRANSFORMER 38 39 5,346 14,744 40 41 5,346 17,628 42 SUBTOTAL 1 16,755 1 15,321 1 14,315 1 LOAD CONN. VA DF LOAD F -27-,88-8T23,496 26,380 SUBTOTAL TOTAL PHASE A - VA 44,643 AMPS 161 TOTAL PHASE B - VA 38,817 AMPS 140 TOTAL PHASE C - VA 40,695 AMPS 147 TOTAL PANEL - VA 124,155 AMPS 149 CONN. VA DF LCK - LOCKABLE TAB EM - EMERGENCY LIGHTS THIS CIRCUIT OL - REFER TO ONE LINE COOLING HEATING 42,945 LIGHTING 3,446 GEN. RECEPTS MOTORS SUPP. HEAT MISC EQUIP 12,934 1.00 1.00 1.25 1.0/.5 1.00 1.00 0.50 REFRIGERATION 1.00 DISPLAY CASE 1.25 KITCHEN 1.00 TOTAL DEMAND VA 93,498 AMPS 112 PANELBOARD: CSC2 FAULT CURRENT: <10,000A EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: 10,000A MAIN SIZE/TYPE: 150A MCB SERVES: COLD STONE CREAMERY VOLTS/PHASE: 208Y/12OV, 3PH, 4W MOUNTING: SURFACE SECTIONS : 1 LOCATION: WORK AREA CKT NO. DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS/PHASE DESCRIPTION CKT A B C N0. A B C 1 CEILING FANS 1,200 12 20 1 1 20 12 1,176 FROST TOP 2 3 FROST TOP 1,176 12 20 1 2 20 12 _ 1,196 -HARD ---NING CABINET 4 1,196 6 5 DIPPING CABINET 1,040 12 20 2 7 1,040 1 20 12 504 DIP SERVER 8 9 WALK-IN COOLER 874 12 20 2 3 45 6 4,320 BATCH FREEZER 10 4,320 12 4,320 14 11 874 13 REACH IN 2 DOOR FREEZER 1,236 12 20 1 15 WALK-IN FREEZER 2,080 10 30 2 1 20 12 1,380 UNDER COUNTER FREEZER/REFRIG 16 17 2,080 1 20 12 1,848 BLEND/HOT TOPPING 18 19 SPARE 2 LAMP FLUORESCENT 1' X 4' XX 20 1 1 20 12 360 TELEPHONE BOARD RECEPT 20 21 SPARE XX 20 1 1 20 12 134 COOLER/FREEZER LIGHTS 22 180 CASH REGISTER 24 23 CONVENIENCE RECEPT 1,260 12 20 1 1 20 12 25 TIMESWITCHES 200 12 20 1 1 20 1 12 1,600 CONVECTION OVEN 26 27 DUCT DETECTOR 180 12 20 1 1 20 12 708 REFRIGERATED DISPLAY CASE 28 29 SIGNAGE 1,200 10 20 1 2 35 8 2,600 REFRIGERATED DISPLAY CASE 30 2,600 32 31 SHOW WINDOW RECEPT 360 12 20 1 33 MUSAK RECEPT 500 12 20 1 1 20 12 1,200 TENANT SIGNAGE (FUTURE) 34 180 CASH REGISTER 36 35 COMPUTER RECEPT 360 12 20 1 1 20 12 37 CONE IRON 996 12 20 1 1 20 12 996 CONE IRON 38 39 CONE IRON 996 12 20 1 1 20 12 SPARE 40 41 EF -1 130 12 15 1 1 20 12 360 CU FCU RECEPT 42 SUBTOTAL 77 7K5,806 1 6,944 LOAD CONN. VA DF 11,556 8,938 1 10,684 1 SUBTOTAL TOTAL PHASE A - VA 16,588 AMPS 138 TOTAL PHASE B - VA 14,744 AMPS 123 TOTAL PHASE C - VA 17,628 AMPS 147 TOTAL PANEL - VA 48,960 AMPS 136 1 LOAD CONN. VA DF REFRIGERATION 6,376 1.00 TS - VIA TIMESWITCH DISPLAY CASE 1,25 KITCHEN 34,072 0.65 TOTAL DEMAND VA 1 39,778 AMPSI 110 COOLING HEATING LIGHTING 11334 GEN. RECEPTS 5,668 MOTORS 1,3.30 SUPP. HEAT MISC EQUIP 180 1.00 1.00 1.25 1.0/. 1.00 1.00 0.50 J)NUW WINUUW LlUMINU LUAU IWLUUtU IN rttULN ULMANU BUILDING ELECTRICAL SERVICE LOAD SUMMARY MANUFACTURER VOLTAGE/ MARK MODEL NUMBER INPUT WATTS LAMP TYPE MOUNTING REMARKS BUILDING OCCUPANCY TYPE: M BUILDING SQUARE FOOTAGE: 1,694 SERVICE DESCRIPTION: 480Y/277V, 3PH, 4W LOAD DESCRIPTION Connected KVA Demand FACTOR Demand KVA HVAC - SUMMER 15.87 100% 0.00 HVAC - WINTER 42.95 100% 42.95 LIGHTING 3.58 125% 4.48 RECEPTACLES 5.67 100%;50% 5.67 KITCHEN EQUIPMENT 34.07 65% 22.15 MOTOR LOADS 1.33 100% 1.33 SUPPLEMENTAL ELECTRIC HEAT 0.00 100% 0.00 MISCELLANEOUS EQUIPMENT 13.11 50% 6.56 REFRIGERATION EQUIPMENT 6.38 100% 6.38 DISPLAY CASE 0.00 125% 0.00 COMPUTER LOADS 0.00 100%1 0.00 EXTERIOR LIGHTING 1.20 125%1 1.50 TOTAL LOAD 124.16 KVA 93.50 TOTAL AMPACITY 149.34 AMPS 112.46 SERVICE AMPACITY 200 AMPS 200.00 SPARE CAPACITY 51 AMPS 88 SHOW WINDOW / TRACK LIGHTING DEMAND ADDED TO EXISTING PAD MOUNT UTILITY TRANSFORMER MC C_ EXISTING LANDLORD WIREWAY 480Y/277V 30 4W EXISTING 200A 1 13P NEW 200A LPS-R EXISTING 2" CONDUIT ROUTED FROM -- TENANT SPACE INTO ELECTRICAL ROOM. PROVIDE CONDUCTORS FROM TENANT SPACE TO PANEL "CSC". APPROXIMATE DISTANCE = 100 FT. FIELD VERIFY EXACT LOCATION AND LENGTH AND ADJUST CONDUCTOR SIZE PER NEC AS NECESSARY TO LIMIT VOLTAGE DROP TO 3%. BOND 1 STEEL. NO SCALE CD FEEDER SCHEDULE: 63 60A, (3)#4, (1)#10G, 1" C 204 200A, (4)#3/0, (1)#6G, EXISTING 2" C 6150 150A, #6 BARE COPPER GROUND, 3/4" C T154 150A, (4)#1/0, (1)#6G, 2" C V) 0 KEYED NOTES: Q`� �1 PROVIDE NEW FUSE IN EXISTING DISCONNECT. 0 M [-2] VERIFY EXISTING UTILITY METER SOCKET LOCATION. z PROVIDE METER AS REQUIRED. TX1 45KVA GENERAL NOTES: 480 30 208/120V 30/4W 1. COORDINATE METER SIZE AND LOCATION WITH SERVING UTILITY COMPANY. N 0 V) D 0 o' a 0 m J w z aQ. DIAGRAM LIGHT FIXTURE SCHEDULE (FOR REFERENCE ONLY RE: A-2) MANUFACTURER VOLTAGE/ MARK MODEL NUMBER INPUT WATTS LAMP TYPE MOUNTING REMARKS LSI #26910; FILE NAME: 0450000591E2.dwg SERIES 206V CFL 142W TPL DATE: -1/2/04 ° 6" RECESSED VERTICAL L1 UNIV CLBK DGCF 277V/42W 1/42W TRI -TUBE FLUOR. RECESSED DOWNLIGHT LSI #27282; REVIEWED BY: RAN 6" RECESSED VERTICAL SERIES 206H CFL 142W TPL REV. DESCRIPTION DATE DOWNLIGHT/FOOD PREP L2 UNIV W C 277V/42W 1/42W TRI -TUBE FLUOR. / RECESSED LENSED LSI #26914; SERIES 206WW CFL 226W 6" RECESSED LENSED L3 QUAD UNIV W LSL 277V/52W 2/26W Q -TUBE FLUOR. RECESSED WALL WASH LSI #26916; SERIES G 2X4 432W T8 4 LAMP L 2' X 4' L4 LBAUNIV 277V/128W (4) 32W. T8 RECESSED RECESSED URE LSI #26918; SERIES 78 11-1/2" 4' 232W T8 UNIV 2 LAMP FLUORESCENT 1' X 4' L5 277V/67W (2) 32W. T8 SURFACE RECESSED FIXTURE LSI EMERGENCY EXIT SIGN WITH LIGHT EMEX-2-R-B-120/277 HEADS AND INTEGRAL BATTERY L6 277V/14W W/ FIXTURE UNIVERSAL BACKUP LSI EMERGENCY EXIT SIGN WITH EMEXR-2-R-W-120/277 EMERGENCY LIGHTING, REMOTE HEADS L7 277V/14W W/ FIXTURE UNIVERSAL AND INTEGRAL BATTERY BACKUP FURNISHED BY WALK-IN COOLER FURNISHED BY WALK-IN COOLER MANUFACTURER, INSTALLED BY L8 MANUFACTURER 120V/67W (2) 32W. T8 SURFACE ELECTRICAL CONTRACTOR LSI EM -B-120/277 EMERGENCY LIGHTING WITH EM 277V/12W W/ FIXTURE UNIVERSAL INTEGRAL BATTERY BACKUP LSI EXIT SIGN WITH INTEGRAL BATTERY EX -2 -R -B -120/277 -EM BACKUP EX 277V 4W W/ FIXTURE UNIVERSAL SCHEDULE NOTES: 1. SUPPLY FIXTURES AS SPECIFIED, NO SUBSTITUTIONS ALLOWED. 2. FIXTURES WILL BE SUPPLIED BY NATIONAL ACCOUNT DISTRIBUTOR AND SHIPPED COMPLETE WITH EXCEPTION OF "BY OWNER" FIXTURES. NO BACKORDERS ALLOWED. 3, ALLOW 2 WEEKS FOR SHIPPING AFTER FACTORY RECEIPT OF ORDER. 4. ALL LAMPS PER COLD STONE CREAMERY SPECIFIED COLOR TEMPERATURE. 5. TYPES 12' AND 13' SHALL BE USED OVER ALL FOOD PREP AREAS. 6. SPACING OF FIXTURES SHALL REMAIN CONSISTENT WITH BASE PLANS TO MAINTAIN COLD STONE CREAMERY'S LIGHTING CRITERIA. NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. cohl) acl mlON& 2944 N. 44TH STREET, SUITE 150 PHOENIX, ARIZONA 85018 (602) 277-7877 PH (602) 277-8288 FAX ENGINEER: M u9j HENDERSON ENGINEERS INCORPORATED 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENCINEERS.COM 0450000591 ARCHITECT: DAVID A. MOW, ARCHITECT 11881 N. 113th WAY SCOTTSDALE, AZ 85259 (602) 277-7877 PH (602) 277-8288 FAX OWNER DON 5ALATIC:H -1424 WYN5TONE COURT WE5T CHE-5TER, CH 080(o9 PROJECT TITLE COLD 5TONE CREA EERY CLAY TEfRRACE - 5UITE 528 CAfiR IEL, IN 46033 STOfRE # 1241 PROJECT NO: 04221 r FILE NAME: 0450000591E2.dwg DATE: -1/2/04 ° DRAWN BY: ARCS REVIEWED BY: RAN REV. DESCRIPTION DATE CITY SUBMITTAL 1/2/04 SHEET TITLE ELECTRICAL SCHEDULES, SPECIFICATIONS & DETAILS SHEET NO. E-2