Loading...
HomeMy WebLinkAboutENERGY CERTIFICATEEnergy Code Inspection Checklist Property Drees Homes 12190 Frenzel Parkway Carmel, IN 46032 Weather:Indianapolis, IN Layton CON BST 4BD SUN RM BN RM DREIN-JG 193-12190 Frenzel Organization Top Build Home Services 866-912-7233 Alan Smith Builder Drees Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 3/27/2018 Building Information Conditioned Area (sq ft)5156 Conditioned Volume (cubic ft)50236 Insulated Shell Area (sq ft)10268 The building assemblies and the energy features listed below have been modeled to demonstrate compliance with the IECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. Top Build Home Services's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings [ ]1.Attic: R-40 Blown, Attic* (1960 s.f.) R-27.0 continuous insulation, R-13.0 cavity insulation. Name: FLAT Insulation Grade: I II III Face / Inset Comments/Location [ ]2.Vaulted: R-38, Vaulted0* (170 s.f.) R-27.0 continuous insulation, R-13.0 cavity insulation. Name: SLOPED Insulation Grade: I II III Face / Inset Comments/Location Above-Grade Walls [ ]1.Wall: R-15 (2x4) OSB* (3114 s.f.), Between conditioned space and ambient R-0.0 continuous insulation, R-15.0 cavity insulation. Name: AMB Insulation Grade: I II III Face / Inset Comments/Location [ ]2.Wall: R-15 (2x4)* (612 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-15.0 cavity insulation. Name: GAR Insulation Grade: I II III Face / Inset Comments/Location Energy Code Inspection Checklist Property Drees Homes 12190 Frenzel Parkway Carmel, IN 46032 Weather:Indianapolis, IN Layton CON BST 4BD SUN RM BN RM DREIN-JG 193-12190 Frenzel Organization Top Build Home Services 866-912-7233 Alan Smith Builder Drees Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 3/27/2018 Page 2 of 6 Above-Grade Walls [ ]3.Wall: R-15 (2x4)* (255 s.f.), Between conditioned space and attic R-0.0 continuous insulation, R-15.0 cavity insulation. Name: ATTIC KW Insulation Grade: I II III Face / Inset Comments/Location Windows and Skylights Window-to-Wall Area Ratio: 0.12 [ ]1.Window: U=.30 SHGC =.21* (78 s.f., North), U-Value: 0.300, SHGC: 0.210 For windows without labeled U-factors, describe features: Name: FRONT Orientation: North Comments/Location [ ]2.Window: U=.30 SHGC =.21* (76 s.f., East), U-Value: 0.300, SHGC: 0.210 For windows without labeled U-factors, describe features: Name: LEFT Orientation: East Comments/Location [ ]3.Window: U=.30 SHGC =.21* (190 s.f., South), U-Value: 0.300, SHGC: 0.210 For windows without labeled U-factors, describe features: Name: BACK Orientation: South Comments/Location [ ]4.Window: U=.30 SHGC =.21* (66 s.f., South), U-Value: 0.300, SHGC: 0.210 For windows without labeled U-factors, describe features: Name: BACK PORCH Orientation: South Comments/Location [ ]5.Window: U=.30 SHGC =.21* (40 s.f., West), U-Value: 0.300, SHGC: 0.210 For windows without labeled U-factors, describe features: Name: RIGHT Orientation: West Comments/Location Energy Code Inspection Checklist Property Drees Homes 12190 Frenzel Parkway Carmel, IN 46032 Weather:Indianapolis, IN Layton CON BST 4BD SUN RM BN RM DREIN-JG 193-12190 Frenzel Organization Top Build Home Services 866-912-7233 Alan Smith Builder Drees Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 3/27/2018 Page 3 of 6 Windows and Skylights [ ]6.Window: U=.30 SHGC =.21* (18 s.f., West), U-Value: 0.300, SHGC: 0.210 For windows without labeled U-factors, describe features: Name: RIGHT PORCH Orientation: West Comments/Location [ ]7.Window: U=.30 SHGC =.21* (24 s.f., West), U-Value: 0.300, SHGC: 0.210 For windows without labeled U-factors, describe features: Name: RIGHT PORCH FR DR Orientation: West Comments/Location Doors [ ]1.Door: Steel-urth w/brk (24 s.f.), R-Value 4.4 Comments/Location [ ]2.Door: Steel-urth w/brk (21 s.f.), R-Value 4.4 Comments/Location Frame Floors [ ]1.Floor: R-30* (297 s.f.), Between conditioned space and ambient conditions R-0.0 continuous insulation, R-30.0 cavity insulation. Name: OVER GAR Insulation Grade: I II III Face / Inset Comments/Location [ ]2.Floor: R-30* (197 s.f.), Between conditioned space and ambient conditions R-0.0 continuous insulation, R-30.0 cavity insulation. Name: OVER AMB Insulation Grade: I II III Face / Inset Comments/Location Energy Code Inspection Checklist Property Drees Homes 12190 Frenzel Parkway Carmel, IN 46032 Weather:Indianapolis, IN Layton CON BST 4BD SUN RM BN RM DREIN-JG 193-12190 Frenzel Organization Top Build Home Services 866-912-7233 Alan Smith Builder Drees Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 3/27/2018 Page 4 of 6 Slab Floors [ ]1.Slab: Uninsulated (1626 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: SLAB Insulation Grade: I II III Face / Inset Comments/Location Foundation Walls [ ]1.Wall: R-11 Draped, 4ft* (1178 s.f.), Between conditioned space and ambient/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: BGW AMB Insulation Grade: I II III Face / Inset Comments/Location [ ]2.Wall: R-11 Draped, 4ft* (531 s.f.), Between conditioned space and garage/ground R-11.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: BGW GAR Insulation Grade: I II III Face / Inset Comments/Location Rim and Band Joists [ ]1.Joist: AMB (247 s.f.), Between conditioned space and ambient R-0.0 continuous insulation, R-15.0 cavity insulation. Name: AMB Insulation Grade: I II III Face / Inset Comments/Location [ ]2.Joist: ATTIC (81 s.f.), Between conditioned space and ambient R-0.0 continuous insulation, R-15.0 cavity insulation. Name: ATTIC Insulation Grade: I II III Face / Inset Comments/Location Mechanical Equipment [ ]1.Heating: Fuel-fired air distribution, Natural gas, 93.0 AFUE. Make and Model Number [ ]2.Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number Energy Code Inspection Checklist Property Drees Homes 12190 Frenzel Parkway Carmel, IN 46032 Weather:Indianapolis, IN Layton CON BST 4BD SUN RM BN RM DREIN-JG 193-12190 Frenzel Organization Top Build Home Services 866-912-7233 Alan Smith Builder Drees Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 3/27/2018 Page 5 of 6 Mechanical Equipment [ ]3.Water Heating: Conventional, Natural gas, 0.65 EF, 50.0 Gal. Make and Model Number Mechanical Ventilation System [ ]Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 99 cfm, 24.0 hrs/day, 22.5 watts. System description(make) Air Leakage Control [ ]Blower Door Test at Final __________________________ [ ]House is air-sealed so as to achieve 3.00 ACH50 or less at final blower door test. (Max CFM50 is: 2512) [ ]Visual inspection at rough for mandatory code air barrier and insulation features. Infiltration Requirements for IECC 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage and Insulation [ ]Duct System 1 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ]Duct System 1 Leakage to Outside is specified in REM/Rate at 0.030 CFM25 / CFA [ ]Duct System 1 Total Duct Leakage is specified in REM/Rate at 0.040 CFM25 / CFA [ ]Duct System 2 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ]Duct System 2 Leakage to Outside is specified in REM/Rate at 0.030 CFM25 / CFA [ ]Duct System 2 Total Duct Leakage is specified in REM/Rate at 0.040 CFM25 / CFA Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Energy Code Inspection Checklist Property Drees Homes 12190 Frenzel Parkway Carmel, IN 46032 Weather:Indianapolis, IN Layton CON BST 4BD SUN RM BN RM DREIN-JG 193-12190 Frenzel Organization Top Build Home Services 866-912-7233 Alan Smith Builder Drees Homes REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP Registry ID: Date: 3/27/2018 Page 6 of 6 Duct Leakage Code Requirements for IECC Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): Requires ducts be tested and reported, but has no compliance thresholds. Notes 2009 IECC Energy Cost Compliance Property Drees Homes 12190 Frenzel Parkway Carmel, IN 46032 Weather:Indianapolis, IN Layton CON BST 4BD SUN RM BN RM Organization Top Build Home Services 866-912-7233 Alan Smith Builder Drees Homes HERS Projected Rating NA Rating No:NA Rater ID:BDRGNP REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Annual Energy Cost $/yr 2009 IECC As Designed Heating 1255 1145 Cooling 181 141 Water Heating 177 177 SubTotal - Used to Determine Compliance 1613 1463 Lights & Appliances 658 663 Photovoltaics -0 -0 Service Charge 248 248 Total 2519 2374 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.2)PASSES Duct Leakage (Section 403.2.2)PASSES Mandatory Requirements Check Box (2009 IECC)PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 9.3%. Name Alan Smith Signature Organization Top Build Home Services Date 27 March 2018 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 12190 Frenzel Parkway, Carmel, IN by Drees Homes exceeds the minimum requirements for the 2009 International Energy Conservation Code The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Building Features Ceiling Flat R-40.0 Duct NA Sealed Attic:NA Duct Leakage to Outside:0.03 CFM25 / CFA Vaulted Ceiling R-40.0 Total Duct Leakage:0.04 CFM25 / CFA Above Grade Walls R-15.0 Infiltration:Htg: 3.00 Clg: 3.00 ACH50 Foundation Walls R-11.0 Window U-Value: 0.300, SHGC: 0.210 Exposed Floor R-30.0 Heating Fuel-fired air distribution, Natural gas, 93.0 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Natural gas, 0.65 EF, 50.0 Gal. Name Alan Smith Signature Organization Top Build Home Services Date 27 March 2018