Loading...
HomeMy WebLinkAboutA000.31900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office111/14/2016PLAN REVISIONS........................ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 Rick Starkey09/30/2016 LEFT Allison II 2377.300.00.CPM -- 10/14/2016 PLOTTED: December 5, 2016 / Annie Ki / 2377-ALLISON II-CZ-BASE-EL-CR2G.DWG A3-CR2G 3FB.1Craftsman 2G3 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleSCALE:REAR ELEVATION1/8" = 1'-0"- TOP OF PLATE TOP OF PLATE TOP OF FOUNDATION\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF FOUNDATION TOP OF PLATE TOP OF PLATE \A1;9'-1{\H0.750000x;\S1#8;}" \A1;4'-8{\H0.750000x;\S1#8;}"\A1;3'-9{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.\A1;12'-2{\H0.750000x;\S1#8;}"\A1;HDR. HGT. TYP. SCALE:LEFT ELEVATION1/8" = 1'-0"- 127127 OPT. 2/8 SERVICE DOOROPT.OPT.OPT. 127 124 OPT.1 SCALE:RIGHT ELEVATION1/8" = 1'-0"- 127 124 \A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF FOUNDATION TOP OF PLATE TOP OF PLATE 127 OPT.OPT.OPT.OPT.OPT.OPT. SCALE:FRONT ELEVATION1/4" = 1'-0"- \A1;8'-1{\H0.750000x;\S1#8;}" \A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF FOUNDATIONTOP OF FLOOR TOP OF FLOOR TOP OF PLATE WINDOW HEAD HGT. WINDOW HEAD HGT. TOP OF PLATE \A1;2'-2{\H0.750000x;\S7#8;}"\A1;3'-2{\H0.750000x;\S7#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;AT GARAGE\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. AT GARAGE SIMILARCL-01AD 2.1 HORIZONTAL SIDING, PER SPEC 6" TRIM, PER SPEC 8" TRIM, PER SPEC 8" TRIM, PER SPEC 6" RAKE BOARD, PER SPECFRIEZE, PER SPEC ROOF SHINGLES, PER SPEC HORIZONTAL SIDING, PER SPECSHAKE SIDING, PER SPEC 10" TRIM, PER SPEC FYPON #BKT14X16X4, OR EQUIVALENT SHAKE SIDING, PER SPEC 6" TRIM, PER SPEC 6" TRIM, PER SPEC FRIEZE, PER SPEC STONE SILL, PER SPECSTONE VENEER, PER SPEC 6" FASCIA BOARD, PER SPEC 125 125 125125125 125 FYPON #BKT14X16X4, OR EQUIVALENT SCALE:ROOF PLAN1/8" = 1'-0"- "B"406ROOF AREA:SQ. FT. OPT. POT VENTS\A1;6'-0" \A1;21'-0" MIN. 132 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR PORCH ROOF 5:125:125:125:12 5:125:12 4:124:12 7:12 7:127:12 7:12 PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION OPT. GUTTER AND DOWNSPOUTS "A"2031ROOF AREA:SQ. FT. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP.\A1;1'-0"\PTYP. \A1;6'-0" \A1;1'-0"\PTYP. SCALE: SIDE AND REAR WINDOW TRIM PER COMMUNITY SPECS1/4" = 1'-0"- VINYL DIMENSIONAL TRIM ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ELEVATION CR2G ROOF AREA "A"SQ FTG 2031 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 2.71 3.39 3.39 49.90 8 0 AT EAVE 4.06 3.39 3.40 50.10 0 49.00 TOTAL (MIN)6.77 6.77 6.79 100.00 3 HIGH - RIDGE VENT 2.71 3.39 3.38 49.80 0 0 27.00 AT EAVE 4.06 3.39 3.40 50.20 0 49.00 TOTAL (MIN)6.77 6.77 6.78 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "B"SQ FTG 406 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.54 0.68 0.85 48.41 2 0 AT EAVE 0.81 0.68 0.90 51.59 0 13.00 TOTAL (MIN)1.35 1.35 1.75 100.00 3 HIGH - RIDGE VENT 0.54 0.68 0.75 49.54 0 0 6.00 AT EAVE 0.81 0.68 0.76 50.46 0 11.00 TOTAL (MIN)1.35 1.35 1.51 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 05/14/18 David Rutti