Loading...
HomeMy WebLinkAboutA001.01900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office111/14/2016PLAN REVISIONS........................ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 Rick Starkey09/30/2016 LEFT Allison II 2377.300.00.CPM -- 10/14/2016 PLOTTED: December 5, 2016 / Annie Ki / 2377-ALLISON II-CZ-BASE-PLAN.DWG A0 B-1.1Basement Foundation Plan. SUMP w/ CHECK VALVE, VERIFY LOCATIONOPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATION PROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE OPT. 4140 SL & EGRESS WELL #1, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT. 4140 SL & EGRESS WELL #2, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT. 4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT. 4140 SL & EGRESS WELL #3, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) SLOPE \A1;48'-0" - OVERALL\A1;19'-6"\A1;10'-6"\A1;5'-5{\H0.750000x;\S1#2;}" \A1;54'-0" - OVERALL \A1;20'-8" \A1;33'-4" \A1;47'-0" \A1;54'-0" - OVERALL \A1;5'-4" \A1;1'-8" \A1;48'-0" - OVERALL \A1;31'-6"\A1;16'-6" \A1;22'-8{\H0.750000x;\S1#2;}" \A1;10'-7{\H0.750000x;\S1#2;}"\A1;10'-3{\H0.750000x;\S1#2;}" \A1;3'-6{\H0.750000x;\S1#2;}" \A1;3'-6{\H0.750000x;\S1#2;}" \A1;15'-11{\H0.750000x;\S1#2;}" \A1;11'-8" \A1;10'-8"\A1;18'-8" \A1;1'-7{\H0.750000x;\S1#2;}"\A1;16'-3"\A1;1'-7{\H0.750000x;\S1#2;}"\A1;1'-1{\H0.750000x;\S1#2;}"\A1;8'-3"\A1;1'-1{\H0.750000x;\S1#2;}" FURNACE PER MECHANICAL PLANS WATER HEATER, PER SPECOPT. WATER SOFTENER, PER SPEC RADON VENT PER CODE, VERIFY LOCATION \A1;2'-11{\H0.750000x;\S3#4;}" \A1;18'-8" \A1;19'-5"\A1;12'-1" \A1;6'-4"\A1;6'-9"\A1;14'-0{\H0.750000x;\S1#2;}"\A1;4'-4{\H0.750000x;\S1#2;}" \A1;5'-0" \A1;2'-7{\H0.750000x;\S1#4;}" \A1;2'-0" \A1;18'-8" - ℄ OF OPT. DOOR 2A2 B.1 1A2 B.11A2 B.1 2A2 B.1 3A2 B.2 3A2 B.2 4A2 B.2 4A2 B.2 SCALE:BASEMENT FOUNDATION PLAN1/4" = 1'-0"- PERIMETER DRAIN, PER SPEC OPT\PROUGH IN BATHUP 7 RISERSHANDRAIL, PER CODE1234567 \A1;6'-5{\H0.750000x;\S1#2;}"\A1;4'-5{\H0.750000x;\S1#4;}"\A1;7'-0" \A1;29'-4" \A1;20'-6{\H0.750000x;\S1#2;}" \A1;1'-5{\H0.750000x;\S1#2;}" SLAB/UNEXCAVATED (SEE STRUCTURAL PLANS) POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS \A1;12'-6{\H0.750000x;\S1#2;}" \A1;7'-4" \A1;2'-0" \A1;19'-2{\H0.750000x;\S3#4;}"\A1;12'-3{\H0.750000x;\S1#4;}" 12345678 CONCRETE SLABUNEXCAVATED(SEE STRUCTURAL PLANS) BASEMENT - UNFINISHEDSLAB (SEE STRUCTURAL PLANS) LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) \A1;2'-7{\H0.750000x;\S1#2;}"ADD RISER W/ OPT. 9'-0" POUR \pxql;2/8 FD \A1;18'-8"ALTERNATE SUMP PUMP LOCATION - VERIFY LOCATION IN FIELD SCALE:ALTERNATE SUMP PUMP LOCATION1/4" = 1'-0"- 36x60 SHOWER FOUNDATION NOTES\pxi-3,l3,t3;{\LGENERAL SPECIFICATIONS\P}\P1. WHERE DISCREPANCIES BETWEEN SOILS REPORT AND STRUCTURAL DRAWINGS OCCUR, CONTACT THE STRUCTURAL ENGINEER.\P2. FINISH GRADE SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE.\P3. SURFACE WATER TO DRAIN AWAY FROM STRUCTURE. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10 FEET (2% FOR IMPERVIOUS SURFACES)IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P4. GARAGE SLAB SHALL SLOPE A MIN. OF 2" AWAY FROM STRUCTURE.\P5. CONCRETE STOOPS AND PORCH/PATIO SLABS SHALL SLOPE A MIN. OF 1/4" PER FOOT AWAY FROM STRUCTURE.\P6. PROVIDE BEARING LEDGE FOR MASONRY AS INDICATED BY STRUCTURAL DRAWINGS.\P7. FOR ADDITIONAL INFORMATION SEE STRUCTURAL DRAWINGS AND NOTES 05/14/18 David Rutti