Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
I32320886.3_Shadow_wood
Re: Liu, Xuegang Pages or sheets covered by this seal: I32320886 thru I32320957 My license renewal date for the state of Indiana is July 31, 2018. 3_Shadow_wood Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: 3 shadow wood The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. February 2,2018 Job 3_SHADOW_WOOD Truss GE01 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320886 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:19 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-qy1r1eRpIyqPc2a6MXOK7_57lpts17aFv2f6vfzpDdc Scale = 1:37.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 14 2x4 2x4 2x4 3x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 14-0-8 14-0-8 1-10-9 1-10-9 9-10-10 8-0-2 14-0-8 4-1-14 15-0-8 Job 3_SHADOW_WOOD Truss GE02 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320887 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:20 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-J8bDE_RR3FyGEB9IwEvZfBeKdDD5mZnO7iOfR6zpDdb Scale = 1:51.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 3x6 3x6 4x6 4x6 4x6 29-11-0 29-11-0 6-2-8 6-2-8 23-6-10 17-4-2 29-11-0 6-4-6 1-9-4 4-10-8 0-7-9 4-10-8 6.00 12 8.00 12 Plate Offsets (X,Y)-- [20:0-3-12,0-2-0], [36:0-2-10,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 Job 3_SHADOW_WOOD Truss GE03 Truss Type GABLE Qty 2 Ply 1 3 shadow wood Job Reference (optional) I32320888 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:21 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-nL9bSKS3qZ46rLkUUyRoCPARUdURV_dYMM8DzYzpDda Scale = 1:88.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 67 8 9 10 11 12 13 14 15 16 17 18 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 3x4 3x4 3x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job 3_SHADOW_WOOD Truss GE04 Truss Type GABLE Qty 2 Ply 1 3 shadow wood Job Reference (optional) I32320889 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:21 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-nL9bSKS3qZ46rLkUUyRoCPANtdVfVwgYMM8DzYzpDda Scale = 1:97.2 Sheet Front Right Option 8-8-8 1 Ply 7/16OSB8 1 2 3 4 5 6 12 11 10 9 8 7 3x6 3x6 4x10 4x8 3x6 3x6 2x4 3x4 3x6 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6-8-13 6-8-13 11-3-8 4-6-11 Job 3_SHADOW_WOOD Truss GE05 Truss Type GABLE COMMON Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320890 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:22 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-FXj_ffTibtCzTVJh1fy1lcje?0uzETHhb0tmW_zpDdZ Scale: 1/4"=1' Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 4x6 2x4 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 Job 3_SHADOW_WOOD Truss GE06 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320891 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:23 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-jjGMs?UKMAKq5futbNTGHqGlhQ9IzuMrqgdK2RzpDdY Scale = 1:119.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 5x8 2x4 5x6 5x8 3x6 5x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job 3_SHADOW_WOOD Truss GE07 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320892 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:23 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-jjGMs?UKMAKq5futbNTGHqGnFQ91zvWrqgdK2RzpDdY Scale = 1:66.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 13 12 11 10 9 8 2x4 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-4-12 9-4-12 9-4-12 9-4-12 0-0-4 7-10-0 10.00 12 Plate Offsets (X,Y)-- [7:0-4-2,Edge], [8:0-2-8,Edge], [15:0-1-4,0-1-0], [16:0-0-11,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 Job 3_SHADOW_WOOD Truss GE08 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320893 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:24 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Bwqk4LVy7UShipS394_Vq1o?qqaMiLm_2KMtatzpDdX Scale = 1:54.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 2x4 3x4 4x6 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-8-8 13-8-8 -1-0-0 1-0-0 6-10-4 6-10-4 Job 3_SHADOW_WOOD Truss GE09 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320894 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:25 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-f6O6HhVauoaYKz1GjoVkMFL82EwzRoy7H_6Q6JzpDdW Scale = 1:90.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 3x4 3x4 4x6 3x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job 3_SHADOW_WOOD Truss J01 Truss Type Jack-Closed Qty 4 Ply 1 3 shadow wood Job Reference (optional) I32320895 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:25 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-f6O6HhVauoaYKz1GjoVkMFL0hEriRjM7H_6Q6JzpDdW Scale = 1:102.2 1 2 3 4 5 10 9 8 7 6 11 12 3x6 8x8 3x6 4x8 3x6 5x8 3x4 3x6 3x4 3x6 3x6 3x6 11-11-2 6-8-5 6-8-5 13-2-3 6-5-13 19-10-8 6-8-5 6-8-5 6-8-5 13-2-3 6-5-13 19-10-8 6-8-5 1-3-5 14-6-5 9-1-12 14-6-5 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-2-9], [5:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL Job 3_SHADOW_WOOD Truss J02 Truss Type Jack-Closed Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320896 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:26 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-7IyUV1WCf5iPy6cSGV0zvSu8FeCsAAnHWer_flzpDdV Scale = 1:81.9 1 2 3 4 7 6 5 8 8x14 MT18HS 3x6 5x8 3x4 4x8 3x4 3x6 7-7-12 7-7-12 15-3-9 7-7-12 15-5-5 0-1-12 7-7-12 7-7-12 15-3-9 7-7-12 15-7-1 0-3-8 1-3-5 11-8-1 8-11-5 11-8-1 8.00 12 Plate Offsets (X,Y)-- [4:0-4-8,Edge], [7:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code Job 3_SHADOW_WOOD Truss J03 Truss Type Jack-Closed Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320897 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:26 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-7IyUV1WCf5iPy6cSGV0zvSuD2eDwAD9HWer_flzpDdV Scale = 1:71.3 1 2 3 4 7 6 5 8 3x6 6x6 3x6 6x8 3x4 6x6 3x4 6-6-10 6-6-10 13-1-3 6-6-10 13-2-15 0-1-12 6-6-10 6-6-10 13-1-3 6-6-10 13-4-11 0-3-8 1-3-5 10-2-8 9-2-1 10-2-8 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-2-9], [4:0-2-9,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code Job 3_SHADOW_WOOD Truss J04 Truss Type Jack-Open Qty 5 Ply 1 3 shadow wood Job Reference (optional) I32320898 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:26 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-7IyUV1WCf5iPy6cSGV0zvSuIYeFhAHxHWer_flzpDdV Scale = 1:31.3 1 2 5 3 4 3x6 3x4 4-0-0 4-0-0 -1-0-0 1-0-0 4-0-0 4-0-0 1-3-0 4-7-0 4-1-3 4-7-0 10.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.37 Job 3_SHADOW_WOOD Truss J05 Truss Type Jack-Open Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320899 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:26 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-7IyUV1WCf5iPy6cSGV0zvSuMXeHTAHxHWer_flzpDdV Scale = 1:15.1 1 2 5 3 2x4 4 2x4 2-0-0 2-0-0 -1-0-0 1-0-0 2-0-0 2-0-0 0-11-0 1-11-0 1-6-5 1-11-0 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.11 0.04 0.00 Job 3_SHADOW_WOOD Truss J06 Truss Type Jack-Open Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320900 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:27 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-bVWtiNXqQPqGZGBeqCXCRgQV01cXvkAQkIbXBCzpDdU Scale = 1:14.7 1 2 5 3 4 3x4 2x4 1-4-15 1-4-5 -1-11-5 1-11-5 1-4-15 1-4-15 1-3-0 1-10-4 5.15 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.26 0.05 0.00 Job 3_SHADOW_WOOD Truss J07 Truss Type Jack-Open Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320901 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:27 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-bVWtiNXqQPqGZGBeqCXCRgQWh1cQvkAQkIbXBCzpDdU Scale = 1:18.3 1 2 5 3 4 2x4 2x4 2-0-0 2-0-0 -1-0-8 1-0-8 2-0-0 2-0-0 1-1-5 2-5-5 2-0-2 2-5-5 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.15 0.06 Job 3_SHADOW_WOOD Truss J08 Truss Type Jack-Open Structural Gable Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320902 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:27 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-bVWtiNXqQPqGZGBeqCXCRgQW?1cevkAQkIbXBCzpDdU Scale = 1:17.9 1 2 5 3 4 2x4 2x4 0-2-9 0-2-9 2-5-9 2-3-0 -1-4-0 1-4-0 2-5-9 2-5-9 1-1-3 2-4-9 0-4-11 1-11-13 2-4-8 6.25 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Job 3_SHADOW_WOOD Truss M01 Truss Type Monopitch Qty 9 Ply 1 3 shadow wood Job Reference (optional) I32320903 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:28 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-4h4FwjYSBjy7BQmqOw3R_tzVVRu_e0CazyK5jezpDdT Scale = 1:77.0 1 2 3 4 5 6 11 10 9 8 7 12 13 3x6 4x8 10x10 4x8 3x6 3x6 3x4 3x4 3x6 3x6 6-10-0 6-10-0 13-5-8 6-7-8 20-3-8 6-10-0 -1-0-0 1-0-0 6-10-0 6-10-0 13-5-8 6-7-8 20-3-8 6-10-0 0-11-0 11-0-12 9-1-12 11-0-12 6.00 12 Plate Offsets (X,Y)-- [6:0-4-8,Edge], [11:Edge,0-7-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 Job 3_SHADOW_WOOD Truss M02 Truss Type Monopitch Qty 5 Ply 1 3 shadow wood Job Reference (optional) I32320904 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 10:47:24 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-naEqBWzhgLP53zOkBK6nBSMHrjMTHFnpZTffl0zpCDX Scale = 1:67.6 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 3x6 2x4 2x4 3x6 2x4 2x4 3x4 4x6 3x8 4x8 3x4 3x6 4x8 6x10 3x6 3x6 1-3-0 1-3-0 2-3-8 1-0-8 8-4-12 6-1-4 14-6-0 6-1-4 20-3-8 5-9-8 -1-0-0 1-0-0 1-3-0 1-3-0 2-3-8 1-0-8 Job 3_SHADOW_WOOD Truss M03 Truss Type Monopitch Qty 8 Ply 1 3 shadow wood Job Reference (optional) I32320905 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:29 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Yted73Y5y04_paL1ydagX5WnDrGsNXajCc4eF4zpDdS Scale = 1:45.7 1 2 3 4 7 6 5 3x6 10x10 4x6 3x4 3x4 5-6-0 5-6-0 11-0-0 5-6-0 -1-0-0 1-0-0 5-6-0 5-6-0 11-0-0 5-6-0 0-11-0 6-5-0 6.00 12 Plate Offsets (X,Y)-- [7:Edge,0-7-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. Job 3_SHADOW_WOOD Truss M04 Truss Type Monopitch Qty 6 Ply 1 3 shadow wood Job Reference (optional) I32320906 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:29 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Yted73Y5y04_paL1ydagX5Wp2rHFNegjCc4eF4zpDdS Scale = 1:29.6 1 2 3 5 4 3x6 3x4 2x4 2x4 4-10-8 4-10-8 -1-0-0 1-0-0 4-10-8 4-10-8 1-1-0 4-4-0 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.28 0.10 0.00 DEFL. Job 3_SHADOW_WOOD Truss M05 Truss Type Monopitch Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320907 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:29 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Yted73Y5y04_paL1ydagX5WpXrH7NegjCc4eF4zpDdS Scale = 1:29.6 1 2 4 3 3x4 3x6 3x4 2x4 4-10-8 4-10-8 4-10-8 4-10-8 1-1-0 4-4-0 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.32 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Job 3_SHADOW_WOOD Truss T01 Truss Type Hip Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320908 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:30 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-03C?KPZjjKCrQkwDVL5v3I2u0Fbq64JsRGpBoXzpDdR Scale = 1:46.5 1 2 3 4 5 9 8 7 6 3x8 4x6 4x6 2x4 3x4 3x8 3x4 6x6 3-10-9 3-10-9 7-10-10 4-0-2 14-0-8 6-1-14 3-10-9 3-10-9 7-10-10 4-0-2 14-0-8 6-1-14 15-0-8 1-0-0 3-1-12 6-4-9 1-3-0 6-4-9 10.00 12 Plate Offsets (X,Y)-- [2:0-4-4,0-2-0], [3:0-4-4,0-2-0], [4:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code Job 3_SHADOW_WOOD Truss T02 Truss Type HIP Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320909 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:30 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-03C?KPZjjKCrQkwDVL5v3I2?5FdI6?TsRGpBoXzpDdR Scale = 1:62.0 1 2 3 4 5 6 11 10 9 8 7 2x4 4x6 3x6 3x4 3x8 3x8 2x4 3x8 2x4 3x4 3-0-7 3-0-7 5-10-9 2-10-2 5-10-10 0-0-1 5-10-10 0-0-1 9-10-7 3-11-12 14-0-8 4-2-1 3-0-7 3-0-7 5-10-9 2-10-2 5-10-10 0-0-1 5-10-10 0-0-1 9-10-7 3-11-12 14-0-8 4-2-1 15-0-8 1-0-0 3-1-12 Job 3_SHADOW_WOOD Truss T03 Truss Type Common Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320910 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:31 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-UGlNYkaLUeKi2uVP32c8cWbAeezZrWW0fwZlKzzpDdQ Scale = 1:62.1 1 2 3 4 5 6 11 10 9 8 7 3x6 4x6 2x4 2x4 3x4 3x4 3x8 3x4 3x4 3x6 3-0-9 3-0-9 5-10-10 2-10-1 9-10-5 3-11-11 14-0-8 4-2-3 3-0-9 3-0-9 5-10-10 2-10-1 9-10-5 3-11-11 14-0-8 4-2-3 15-0-8 1-0-0 3-1-12 8-0-9 1-3-0 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 Job 3_SHADOW_WOOD Truss T04 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320911 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:31 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-UGlNYkaLUeKi2uVP32c8cWb4meucrSu0fwZlKzzpDdQ Scale = 1:57.2 1 2 3 4 5 6 7 14 13 12 11 10 9 8 4x6 4x8 4x6 3x4 3x6 3x6 3x6 3x4 2x4 3x8 3x4 3x6 2x4 4x8 4-10-8 4-10-8 9-6-8 4-8-0 15-3-9 5-9-1 21-0-10 5-9-1 25-5-12 4-5-2 29-11-0 4-5-4 4-10-8 4-10-8 9-6-8 4-8-0 15-3-9 5-9-1 21-0-10 5-9-1 25-5-12 4-5-2 29-11-0 4-5-4 1-9-4 Job 3_SHADOW_WOOD Truss T05 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320912 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:32 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-ySJll4bzFxSZg14cdm7N8j7AL2FdauQ9uaIIsPzpDdP Scale = 1:66.9 1 2 3 4 5 6 12 11 10 9 8 7 6x6 4x8 4x6 3x6 3x6 3x6 3x8 3x4 3x8 3x6 2x4 4x8 6-6-8 6-6-8 12-10-8 6-4-0 18-6-10 5-8-2 24-2-12 5-8-2 29-11-0 5-8-4 6-6-8 6-6-8 12-10-8 6-4-0 18-6-10 5-8-2 24-2-12 5-8-2 29-11-0 5-8-4 1-9-4 8-2-8 0-7-9 8-2-8 6.00 12 8.00 12 Job 3_SHADOW_WOOD Truss T06 Truss Type Roof Special Qty 4 Ply 1 3 shadow wood Job Reference (optional) I32320913 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:32 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-ySJll4bzFxSZg14cdm7N8j7Fu2DMavq9uaIIsPzpDdP Scale = 1:73.6 1 2 3 4 5 6 7 12 11 10 9 8 3x6 5x6 3x6 3x6 3x6 3x6 3x6 3x8 3x6 2x4 6x6 4x8 8-1-15 8-1-15 16-1-7 7-11-7 23-0-2 6-10-11 29-11-0 6-10-14 8-1-15 8-1-15 16-1-7 7-11-7 23-0-2 6-10-11 29-11-0 6-10-14 1-9-4 9-9-15 0-7-9 6.00 12 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [4:0-3-11,0-2-8], [7:0-3-8,Edge], [11:0-2-8,0-1-8] LOADING (psf) TCLL Job 3_SHADOW_WOOD Truss T07 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320914 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:33 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Qet8zQcb?FbPHBfoBTechwgRMSckJJHJ7E2sOszpDdO Scale = 1:48.9 1 2 3 4 5 6 13 12 11 10 9 8 7 4x6 4x8 4x6 3x4 3x6 3x6 3x6 3x4 2x4 4x8 4x6 2x4 4x6 4-8-7 4-8-7 9-2-5 4-5-15 15-3-1 6-0-11 21-3-12 6-0-11 23-1-0 1-9-4 4-8-7 4-8-7 9-2-5 4-5-15 15-3-1 6-0-11 21-3-12 6-0-11 23-1-0 1-9-4 1-9-4 6-4-7 5-2-4 6-4-7 6.00 12 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [3:0-5-0,0-2-0], [5:0-4-4,0-2-0], [8:0-2-8,0-2-0], [12:0-2-8,0-1-8] LOADING (psf) Job 3_SHADOW_WOOD Truss T08 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320915 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:33 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Qet8zQcb?FbPHBfoBTechwgNZSbZJLdJ7E2sOszpDdO Scale = 1:59.4 1 2 3 4 5 11 10 9 8 7 6 5x6 4x6 4x6 3x4 3x6 3x6 3x6 3x4 4x8 3x8 2x4 6-4-7 6-4-7 12-6-5 6-1-15 18-9-12 6-3-7 23-1-0 4-3-4 6-4-7 6-4-7 12-6-5 6-1-15 18-9-12 6-3-7 23-1-0 4-3-4 1-9-4 8-0-7 5-2-4 8-0-7 6.00 12 8.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [3:0-5-0,0-2-0], [4:0-3-12,0-2-0], [5:Edge,0-1-12], [10:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 Job 3_SHADOW_WOOD Truss T09 Truss Type ROOF SPECIAL Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320916 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:33 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Qet8zQcb?FbPHBfoBTechwgNhSZfJLmJ7E2sOszpDdO Scale = 1:72.8 1 2 3 4 5 10 9 8 7 6 3x6 5x6 5x6 3x6 3x6 3x6 3x6 5x6 3x8 3x4 8-0-7 8-0-7 15-10-5 7-9-15 16-3-12 0-5-7 23-1-0 6-9-4 8-0-7 8-0-7 15-10-5 7-9-15 16-1-1 0-2-11 16-3-12 0-2-11 23-1-0 6-9-4 1-9-4 9-8-7 5-2-4 6.00 12 8.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [4:0-2-15,Edge], [5:Edge,0-1-12], [9:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL Job 3_SHADOW_WOOD Truss T10 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320917 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:34 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-urRWAmcDmZjGvLD_kB9rE8DWmswD2ocSLtnPxIzpDdN Scale = 1:73.2 1 2 3 4 5 10 9 8 7 6 3x6 5x6 5x8 3x6 3x6 3x6 3x4 6x6 3x8 3x4 8-1-15 8-1-15 16-1-7 7-11-7 23-1-0 6-11-9 8-1-15 8-1-15 16-1-7 7-11-7 23-1-0 6-11-9 1-9-4 9-9-15 5-2-4 6.00 12 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [4:0-3-6,0-2-8], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Job 3_SHADOW_WOOD Truss T11 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320918 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:34 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-urRWAmcDmZjGvLD_kB9rE8DZ5sw62o7SLtnPxIzpDdN Scale = 1:73.1 1 2 3 4 5 6 12 11 10 9 8 7 3x6 4x6 4x6 3x4 3x6 3x6 3x4 4x8 4x8 2x4 5x6 3x8 8-1-15 8-1-15 16-1-7 7-11-7 18-4-12 2-3-5 18-6-8 0-1-12 26-7-8 8-1-0 26-9-4 0-1-12 8-1-15 8-1-15 16-1-7 7-11-7 18-4-12 2-3-5 26-9-4 8-4-8 1-9-4 9-9-15 2-8-12 6.00 12 8.00 12 Job 3_SHADOW_WOOD Truss T12 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320919 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:35 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-M1?uO6dsXsr7XVoBIuh4mLlmwGGTnFKcaXXyTkzpDdM Scale = 1:73.1 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 3x6 4x6 3x6 3x4 3x6 3x6 3x4 4x8 4x6 3x4 3x8 2x4 3x6 5x6 3x6 8-1-15 8-1-15 16-1-7 7-11-7 18-4-12 2-3-5 18-6-8 0-1-12 23-9-0 5-2-8 29-0-3 5-3-4 29-1-15 0-1-12 29-3-11 0-1-12 8-1-15 8-1-15 16-1-7 7-11-7 18-4-12 Job 3_SHADOW_WOOD Truss T13 Truss Type Roof Special Qty 2 Ply 1 3 shadow wood Job Reference (optional) I32320920 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:35 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-M1?uO6dsXsr7XVoBIuh4mLlmxGGVnEccaXXyTkzpDdM Scale = 1:73.7 1 2 3 4 5 6 7 8 14 13 12 11 10 9 3x6 4x6 3x6 3x4 3x6 3x6 3x4 4x8 4x6 3x4 3x6 2x4 5x6 4x6 8-1-15 8-1-15 16-1-7 7-11-7 18-4-12 2-3-5 24-1-13 5-9-1 29-11-0 5-9-3 8-1-15 8-1-15 16-1-7 7-11-7 18-4-12 2-3-5 24-1-13 5-9-1 29-11-0 5-9-3 1-9-4 Job 3_SHADOW_WOOD Truss T14 Truss Type Roof Special Qty 8 Ply 1 3 shadow wood Job Reference (optional) I32320921 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:36 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-rDZGbSeUIAz_8fNNsbCJJZIwvfZEWcJlpBGW?AzpDdL Scale = 1:109.5 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 3x6 5x6 3x6 3x6 5x8 3x6 3x6 4x10 3x4 3x6 4x6 5x8 3x6 2x4 3x4 5x6 4x8 11-5-7 6 -8-0 6-8-0 13-1-8 6-5-8 19-7-0 6-5-8 25-1-7 5-6-7 32-0-2 6-10-11 Job 3_SHADOW_WOOD Truss T15 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320922 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:36 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-rDZGbSeUIAz_8fNNsbCJJZIyzfcRWetlpBGW?AzpDdL Scale = 1:75.3 1 2 3 4 5 6 7 13 12 10 9 8 11 3x6 5x6 3x6 3x4 3x6 3x6 3x4 3x8 3x6 2x4 5x6 4x8 8-1-15 8-1-15 11-0-0 2-10-1 16-1-7 5-1-7 23-0-2 6-10-11 29-11-0 6-10-14 8-1-15 8-1-15 16-1-7 7-11-7 23-0-2 6-10-11 29-11-0 6-10-14 1-9-4 9-9-15 0-7-9 6.00 12 Job 3_SHADOW_WOOD Truss T16 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320923 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:37 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-JQ7eoof63U5rmpyZQJjYrmr7h3_GFBFu2r03YdzpDdK Scale: 1/4"=1' 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 4x6 10x10 3x6 3x6 3x4 3x4 4x8 4x8 3x6 3x4 3x4 3x6 5-5-4 5-5-4 10-8-0 5-2-12 12-4-8 1-8-8 16-1-8 3-9-0 20-1-0 3-11-8 -1-0-0 1-0-0 5-5-4 5-5-4 10-8-0 5-2-12 12-4-8 1-8-8 16-1-8 3-9-0 20-1-0 3-11-8 21-1-8 1-0-8 0-11-0 Job 3_SHADOW_WOOD Truss T17 Truss Type Roof Special Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320924 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:37 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-JQ7eoof63U5rmpyZQJjYrmr533_2FAgu2r03YdzpDdK Scale = 1:50.5 1 2 3 4 5 6 7 13 12 11 10 9 8 4x6 10x10 3x6 3x6 3x4 3x8 3x6 3x4 3x4 4x6 5-11-2 5-11-2 11-7-11 5-8-10 15-9-2 4-1-6 20-1-0 4-3-14 -1-0-0 1-0-0 5-11-2 5-11-2 11-7-11 5-8-10 15-9-2 4-1-6 20-1-0 4-3-14 21-1-8 1-0-8 0-11-0 6-8-14 1-1-5 6.00 12 8.00 12 Plate Offsets (X,Y)-- [4:0-3-6,0-2-0], [6:0-2-14,0-2-0], [13:Edge,0-7-13] LOADING (psf) TCLL Job 3_SHADOW_WOOD Truss T18 Truss Type Half Hip Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320925 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:38 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-ncg108fkqnDiOyXlz0EnO_NNbTLc_ii2GVlc43zpDdJ Scale = 1:21.0 1 2 3 7 6 4 5 4x6 2x4 2x4 3x4 2-0-0 2-0-0 3-11-4 1-11-4 4-0-0 0-0-12 -1-0-0 1-0-0 2-0-0 2-0-0 4-0-0 2-0-0 1-3-0 2-11-0 10.00 12 Plate Offsets (X,Y)-- [3:0-4-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 Job 3_SHADOW_WOOD Truss T19 Truss Type Half Hip Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320926 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:38 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-ncg108fkqnDiOyXlz0EnO_NMjTMv_iU2GVlc43zpDdJ Scale = 1:27.2 1 2 3 7 6 4 5 4x6 3x4 3x4 2x4 2-0-0 2-0-0 3-2-6 1-2-6 3-11-4 0-8-14 4-0-0 0-0-12 -1-0-0 1-0-0 3-2-6 3-2-6 4-0-0 0-9-10 1-3-0 3-11-0 10.00 12 Plate Offsets (X,Y)-- [3:0-4-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 Job 3_SHADOW_WOOD Truss T20 Truss Type Half Hip Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320927 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:38 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-ncg108fkqnDiOyXlz0EnO_NMuTLq_ia2GVlc43zpDdJ Scale = 1:26.3 1 2 3 7 6 4 5 4x6 3x4 3x4 2x4 2-0-0 2-0-0 3-0-6 1-0-6 3-11-5 0-10-14 4-0-0 0-0-11 -1-0-0 1-0-0 3-0-6 3-0-6 4-0-0 0-11-10 1-3-0 3-9-5 10.00 12 Plate Offsets (X,Y)-- [3:0-4-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 Job 3_SHADOW_WOOD Truss T21 Truss Type Common Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320928 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:39 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-FoEPDTgMb5LZ?66yXkl0xBwSStgKj4XBV9VAcVzpDdI Scale = 1:80.2 1 2 3 4 56 12 11 10 9 8 7 5x6 4x6 3x4 3x6 3x8 3x6 3x4 3x6 3x4 3x4 5x6 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 21-11-0 1-0-0 1-3-0 9-11-9 1-3-0 10.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [5:0-2-12,0-1-8] LOADING (psf) TCLL TCDL Job 3_SHADOW_WOOD Truss T22 Truss Type ROOF TRUSS Qty 2 Ply 1 3 shadow wood Job Reference (optional) I32320929 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:39 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-FoEPDTgMb5LZ?66yXkl0xBwSStgKj4YBV9VAcVzpDdI Scale = 1:80.2 1 2 3 4 5 11 10 9 8 7 6 5x6 4x6 5x6 3x4 3x6 3x8 3x6 3x4 3x6 3x4 3x4 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 1-3-0 9-11-9 1-3-0 10.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [5:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL Job 3_SHADOW_WOOD Truss T23 Truss Type Common Qty 4 Ply 1 3 shadow wood Job Reference (optional) I32320930 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:40 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-j?onRph_MPTQdGh85RGFTPTdGH0dSXkLkpEj8yzpDdH Scale = 1:80.2 1 2 3 4 5 11 10 9 8 7 6 5x6 4x6 5x6 3x4 3x6 3x6 3x4 3x8 3x6 3x4 3x4 5-4-0 5-4-0 10-5-8 5-1-8 15-5-4 4-11-12 20-7-8 5-2-4 5-4-0 5-4-0 10-5-8 5-1-8 15-5-4 4-11-12 20-7-8 5-2-4 1-3-0 9-11-9 1-5-15 10.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [5:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL Job 3_SHADOW_WOOD Truss TG01 Truss Type Common Girder Qty 1 Ply 3 3 shadow wood Job Reference (optional) I32320931 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:40 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-j?onRph_MPTQdGh85RGFTPTbPHxUSSrLkpEj8yzpDdH Scale = 1:62.1 1 2 3 4 8 9 10 11 7 12 13 6 14 5 3x8 4x6 4x6 3x6 3x6 8x8 3x6 4x6 5-10-10 5-10-10 9-9-13 3-11-3 14-0-8 4-2-11 5-10-10 5-10-10 9-9-13 3-11-3 14-0-8 4-2-11 3-1-12 8-0-9 1-3-0 10.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 Job 3_SHADOW_WOOD Truss TG02 Truss Type Common Girder Qty 1 Ply 2 3 shadow wood Job Reference (optional) I32320932 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:41 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-BBM9e9ic7ibHFQGKf9nU0c?lKgKFBveUyT_HhOzpDdG Scale = 1:53.6 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 4x6 4x6 3x6 4x8 3x6 3x6 4x6 3x6 4x6 4x6 3-6-14 3-6-14 6-10-4 3-3-6 10-1-10 3-3-6 13-8-8 3-6-14 -1-0-0 1-0-0 3-6-14 3-6-14 6-10-4 3-3-6 10-1-10 3-3-6 13-8-8 3-6-14 1-3-0 6-11-9 1-3-0 10.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [6:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL Job 3_SHADOW_WOOD Truss TG03 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320933 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:42 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-fNwXsVjFu0j8tarXCsJjYqYvU4hswOqeB7jqDqzpDdF Scale = 1:38.8 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 20 21 22 23 24 4x6 4x6 6x8 4x6 3x6 4x6 3x8 2x4 3x8 3x8 3x6 4x6 3x4 3x6 3-9-12 3-9-12 7-4-0 3-6-4 11-1-4 3-9-4 14-10-8 3-9-4 17-4-0 2-5-8 20-1-0 2-9-0 -1-0-0 1-0-0 3-9-12 3-9-12 7-4-0 3-6-4 11-1-4 Job 3_SHADOW_WOOD Truss TG03 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320933 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:42 2018 Page 2 ID:Timbo7FjJYO_41ssc3TbOxz6zma-fNwXsVjFu0j8tarXCsJjYqYvU4hswOqeB7jqDqzpDdF LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 4=-42(F) 6=-42(F) 15=-82(F) 16=-38(F) 14=-22(F) 13=-22(F) 5=-42(F) 12=-22(F) 18=-42(F) 19=-42(F) 20=-34(F) 21=-22(F) 22=-22(F) 23=-69(F) 24=-46(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 3_SHADOW_WOOD Truss TG04 Truss Type Half Hip Girder Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320934 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:42 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-fNwXsVjFu0j8tarXCsJjYqY414jewWVeB7jqDqzpDdF Scale = 1:14.9 1 2 3 7 6 8 4 9 5 4x6 2x4 2x4 2x4 0-9-10 0-9-10 2-0-0 1-2-6 3-11-4 1-11-4 4-0-0 0-0-12 -1-0-0 1-0-0 0-9-10 0-9-10 4-0-0 3-2-6 1-3-0 1-11-0 10.00 12 Plate Offsets (X,Y)-- [3:0-4-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 Job 3_SHADOW_WOOD Truss TG05 Truss Type Half Hip Girder Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320935 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:42 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-fNwXsVjFu0j8tarXCsJjYqY4h4jCwWXeB7jqDqzpDdF Scale = 1:18.1 1 2 3 7 6 8 4 9 5 4x6 2x4 2x4 3x4 1-5-3 1-5-3 3-11-4 2-6-1 4-0-0 0-0-12 -1-0-0 1-0-0 1-5-3 1-5-3 4-0-0 2-6-13 1-3-0 2-5-5 10.00 12 Plate Offsets (X,Y)-- [3:0-4-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 Job 3_SHADOW_WOOD Truss TG06 Truss Type Flat Girder Qty 1 Ply 2 3 shadow wood Job Reference (optional) I32320936 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:43 2018 Page 1 ID:Xiij0FdRLtocwXuKGcrkgJz6g_o-7aUw3rjtfKr?UkPjmZqy5157SU?LfrjnQnTNlGzpDdE Scale = 1:24.3 1 2 3 6 5 4 7 8 9 10 3x4 4x8 6x10 3x4 2x4 4x8 4-1-0 4-1-0 8-2-0 4-1-0 4-1-0 4-1-0 8-2-0 4-1-0 3-0-0 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.67 0.37 Job 3_SHADOW_WOOD Truss TG06 Truss Type Flat Girder Qty 1 Ply 2 3 shadow wood Job Reference (optional) I32320936 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:43 2018 Page 2 ID:Xiij0FdRLtocwXuKGcrkgJz6g_o-7aUw3rjtfKr?UkPjmZqy5157SU?LfrjnQnTNlGzpDdE LOAD CASE(S) Standard 2) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-656, 4-6=-40 Concentrated Loads (lb) Vert: 7=-574(F) 8=-570(F) 9=-570(F) 10=-570(F) 3) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-9, 4-6=-12 Horz: 1-6=13, 3-4=16 Concentrated Loads (lb) Vert: 7=35(F) 8=36(F) 9=36(F) 10=36(F) 4) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-9, 4-6=-12 Horz: 1-6=-16, 3-4=-13 Concentrated Loads (lb) Vert: 7=35(F) 8=36(F) 9=36(F) 10=36(F) 5) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-9, 4-6=-12 Horz: 1-6=-16, 3-4=16 Concentrated Loads (lb) Vert: 7=35(F) 8=36(F) 9=36(F) 10=36(F) 6) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-103, 4-6=-12 Horz: 1-6=-16, 3-4=16 Concentrated Loads (lb) Vert: 7=35(F) 8=36(F) 9=36(F) 10=36(F) 7) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-143, 4-6=-12 Horz: 1-6=-16, 3-4=16 Concentrated Loads (lb) Vert: 7=35(F) 8=36(F) 9=36(F) 10=36(F) 8) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-165, 4-6=-12 Horz: 1-6=-16, 3-4=16 Concentrated Loads (lb) Vert: 7=35(F) 8=36(F) 9=36(F) 10=36(F) 9) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-9, 4-6=-12 Job 3_SHADOW_WOOD Truss TG06 Truss Type Flat Girder Qty 1 Ply 2 3 shadow wood Job Reference (optional) I32320936 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:43 2018 Page 3 ID:Xiij0FdRLtocwXuKGcrkgJz6g_o-7aUw3rjtfKr?UkPjmZqy5157SU?LfrjnQnTNlGzpDdE LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-3=-165, 4-6=-12 Horz: 1-6=-16, 3-4=16 Concentrated Loads (lb) Vert: 7=-154(F) 8=-152(F) 9=-152(F) 10=-152(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 3_SHADOW_WOOD Truss TG07 Truss Type FLAT GIRDER Qty 1 Ply 3 3 shadow wood Job Reference (optional) I32320937 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:43 2018 Page 1 ID:Xiij0FdRLtocwXuKGcrkgJz6g_o-7aUw3rjtfKr?UkPjmZqy5153QUzFfkqnQnTNlGzpDdE Scale = 1:39.7 1 2 3 4 5 6 7 14 13 12 11 10 9 8 3x8 8x10 4x8 3x8 5x12 10x16 6x18 MT18HS 2x4 5x12 3x6 2x4 5x12 3x6 6x16 2-3-12 2-3-12 7-6-1 5-2-5 12-6-10 5-0-9 17-7-3 5-0-9 22-9-8 5-2-5 2-3-12 2-3-12 7-6-1 5-2-5 12-6-10 5-0-9 17-7-3 5-0-9 22-9-8 5-2-5 3-0-0 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 Job 3_SHADOW_WOOD Truss TG07 Truss Type FLAT GIRDER Qty 1 Ply 3 3 shadow wood Job Reference (optional) I32320937 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:43 2018 Page 2 ID:Xiij0FdRLtocwXuKGcrkgJz6g_o-7aUw3rjtfKr?UkPjmZqy5153QUzFfkqnQnTNlGzpDdE LOAD CASE(S) Standard 2) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-7=-664, 8-14=-40 Concentrated Loads (lb) Vert: 13=-3886(B) 3) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-8, 8-14=-12 Horz: 1-14=13, 7-8=16 Concentrated Loads (lb) Vert: 13=17(B) 4) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-8, 8-14=-12 Horz: 1-14=-16, 7-8=-13 Concentrated Loads (lb) Vert: 13=17(B) 5) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-8, 8-14=-12 Horz: 1-14=-16, 7-8=16 Concentrated Loads (lb) Vert: 13=17(B) 6) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-104, 8-14=-12 Horz: 1-14=-16, 7-8=16 Concentrated Loads (lb) Vert: 13=17(B) 7) Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-144, 8-14=-12 Horz: 1-14=-16, 7-8=16 Concentrated Loads (lb) Vert: 13=17(B) 8) Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-166, 8-14=-12 Horz: 1-14=-16, 7-8=16 Concentrated Loads (lb) Vert: 13=17(B) 9) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-8, 8-14=-12 Job 3_SHADOW_WOOD Truss TG07 Truss Type FLAT GIRDER Qty 1 Ply 3 3 shadow wood Job Reference (optional) I32320937 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:43 2018 Page 3 ID:Xiij0FdRLtocwXuKGcrkgJz6g_o-7aUw3rjtfKr?UkPjmZqy5153QUzFfkqnQnTNlGzpDdE LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-7=-166, 8-14=-12 Horz: 1-14=-16, 7-8=16 Concentrated Loads (lb) Vert: 13=-1003(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 3_SHADOW_WOOD Truss V01 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320938 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:44 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-cm2IGBkVQdzs6t_vKHLBeFdM3uNdOPxwfRCxHjzpDdD Scale = 1:35.0 1 2 3 3x12 4 8x8 3x12 2x4 10-6-7 10-6-7 5-3-4 5-3-4 10-6-7 5-3-4 0-0-4 4-4-11 0-0-4 10.00 12 Plate Offsets (X,Y)-- [1:0-9-13,Edge], [2:Edge,0-2-8], [3:0-7-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.43 0.23 Job 3_SHADOW_WOOD Truss V02 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320939 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:44 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-cm2IGBkVQdzs6t_vKHLBeFdNmuNcOQpwfRCxHjzpDdD Scale = 1:26.3 1 2 3 4 2x4 3x4 2x4 2x4 7-4-1 7-4-1 3-8-0 3-8-0 7-4-1 3-8-0 0-0-4 3-0-11 0-0-4 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.38 0.24 0.04 Job 3_SHADOW_WOOD Truss V03 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320940 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:44 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-cm2IGBkVQdzs6t_vKHLBeFdKAuMuOPFwfRCxHjzpDdD Scale = 1:49.2 1 2 3 2x4 5 4 2x4 2x4 2x4 2x4 7-9-9 7-9-9 0-0-4 6-6-0 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.55 0.28 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in Job 3_SHADOW_WOOD Truss V04 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320941 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:45 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-4ycgUXl7Bx5jk1Z6u_sQASAWGIjv7tx4t5yUq9zpDdC Scale = 1:39.6 1 2 3 2x4 5 4 2x4 2x4 2x4 2x4 6-2-6 6-2-6 0-0-4 5-2-0 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.40 0.23 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Job 3_SHADOW_WOOD Truss V05 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320942 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:45 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-4ycgUXl7Bx5jk1Z6u_sQASATHIhu7te4t5yUq9zpDdC Scale = 1:26.5 1 2 3 2x4 2x4 2x4 4-7-3 4-7-3 0-0-4 3-10-0 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.59 0.36 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a Job 3_SHADOW_WOOD Truss V06 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320943 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:45 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-4ycgUXl7Bx5jk1Z6u_sQASAZxIkM7te4t5yUq9zpDdC Scale = 1:18.6 1 2 3 2x4 2x4 2x4 3-0-0 3-0-0 0-0-4 2-6-0 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.23 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a Job 3_SHADOW_WOOD Truss V07 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320944 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:46 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Y892htmlyFDZLB8IRiNfjgjivh4GsIYD6lh2MbzpDdB Scale = 1:48.7 1 2 3 4 5 3x6 8 7 6 6x6 3x6 2x4 2x4 2x4 2x4 2x4 14-10-12 14-10-12 7-5-6 7-5-6 14-10-12 7-5-6 0-0-4 6-2-8 0-0-4 10.00 12 Plate Offsets (X,Y)-- [3:0-2-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC Job 3_SHADOW_WOOD Truss V08 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320945 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:46 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-Y892htmlyFDZLB8IRiNfjgjjFh4VsJTD6lh2MbzpDdB Scale = 1:39.0 1 2 3 4 5 3x4 8 7 6 6x6 3x4 2x4 2x4 2x4 2x4 2x4 11-8-5 11-8-5 5-10-3 5-10-3 11-8-5 5-10-3 0-0-4 4-10-8 0-0-4 10.00 12 Plate Offsets (X,Y)-- [3:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC Job 3_SHADOW_WOOD Truss V09 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320946 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:47 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-0LjQvDmNiYLQzLjU?PuuFtFqn5MybnINLPRbu2zpDdA Scale = 1:29.9 1 2 3 4 2x4 3x4 2x4 2x4 8-5-15 8-5-15 4-3-0 4-3-0 8-5-15 4-3-0 0-0-4 3-6-8 0-0-4 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.52 0.32 Job 3_SHADOW_WOOD Truss V10 Truss Type Valley Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320947 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:47 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-0LjQvDmNiYLQzLjU?PuuFtFw25QBbnpNLPRbu2zpDdA Scale = 1:20.1 1 2 3 4 2x4 3x4 2x4 2x4 0-0-5 0-0-5 5-3-9 5-3-4 2-7-12 2-7-12 5-3-9 2-7-12 0-0-4 2-2-8 0-0-4 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.19 Job 3_SHADOW_WOOD Truss V11 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320948 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:47 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-0LjQvDmNiYLQzLjU?PuuFtFsc5OVbl?NLPRbu2zpDdA Scale = 1:65.0 Sheet Front Right Option -5-7-14 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 3x4 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 2x4 12-6-12 12-6-12 18-2-10 5-7-14 7-9-11 7-9-11 12-6-12 4-9-1 Job 3_SHADOW_WOOD Truss V12 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320949 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:48 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-UXHp6Yn?TsTHbVIgZ7Q7o5o3iVkwKDTWZ3A8QUzpDd9 Scale = 1:48.6 1 2 3 3x6 5 4 3x6 2x4 3x6 2x4 10-0-12 10-0-12 0-0-4 6-8-8 8.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.32 0.21 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Job 3_SHADOW_WOOD Truss V13 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320950 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:48 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-UXHp6Yn?TsTHbVIgZ7Q7o5o0eVj5KEWWZ3A8QUzpDd9 Scale = 1:38.6 1 2 3 2x4 5 4 2x4 2x4 2x4 2x4 7-6-12 7-6-12 0-0-4 5-0-8 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.45 0.26 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) Job 3_SHADOW_WOOD Truss V14 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320951 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:48 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-UXHp6Yn?TsTHbVIgZ7Q7o5oygVhTKENWZ3A8QUzpDd9 Scale = 1:26.2 1 2 3 2x4 2x4 2x4 5-0-12 5-0-12 0-0-4 3-4-8 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.71 0.43 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a Job 3_SHADOW_WOOD Truss V15 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320952 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:49 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-yjrBKuoeEAc8Cftt7qxMLILG8v623hdfojwizwzpDd8 Scale = 1:13.7 1 2 3 2x4 2x4 2x4 2-6-12 2-6-12 0-0-4 1-8-8 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.15 0.09 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a Job 3_SHADOW_WOOD Truss V16 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320953 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:49 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-yjrBKuoeEAc8Cftt7qxMLILIov733hdfojwizwzpDd8 Scale = 1:9.7 1 2 3 2x4 2x4 2x4 1-6-14 1-6-14 0-0-4 1-0-10 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.04 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a Job 3_SHADOW_WOOD Truss V17 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320954 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:49 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-yjrBKuoeEAc8Cftt7qxMLILCev3I3hdfojwizwzpDd8 Scale = 1:19.8 1 2 3 2x4 2x4 2x4 4-0-14 4-0-14 0-0-4 2-8-10 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.44 0.27 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a Job 3_SHADOW_WOOD Truss V18 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320955 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:50 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-QwPZXEpG?Tk?qoS3gYSbtWtN_JQ2o8Ap1NfFVMzpDd7 Scale = 1:33.2 1 2 3 2x4 5 4 2x4 2x4 2x4 2x4 6-6-14 6-6-14 0-0-4 4-4-10 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.40 0.23 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Job 3_SHADOW_WOOD Truss V19 Truss Type GABLE Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320956 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:50 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-QwPZXEpG?Tk?qoS3gYSbtWtP1JQ8o7Wp1NfFVMzpDd7 Scale = 1:45.7 1 2 3 3x6 5 4 3x6 2x4 2x4 2x4 9-0-14 9-0-14 0-0-4 6-0-10 8.00 12 Plate Offsets (X,Y)-- [1:0-5-10,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.27 0.23 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) Job 3_SHADOW_WOOD Truss V20 Truss Type Valley Qty 1 Ply 1 3 shadow wood Job Reference (optional) I32320957 PROBUILD, MOORESVILLE, IN 46158 7.640 s Aug 16 2017 MiTek Industries, Inc. Fri Feb 02 09:11:50 2018 Page 1 ID:Timbo7FjJYO_41ssc3TbOxz6zma-QwPZXEpG?Tk?qoS3gYSbtWtO5JRvo6cp1NfFVMzpDd7 Scale = 1:55.6 1 2 3 4 3x4 7 6 5 3x8 2x4 3x6 2x4 2x4 2x4 11-6-14 11-6-14 0-0-4 7-8-10 8.00 12 Plate Offsets (X,Y)-- [4:0-3-14,Edge], [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.33 0.18 0.15 DEFL. edge of truss. / 16 " from outside 1 0 - PRODUCT CODE APPROVALS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. W4-6 W3-6 W3-7 W2-7 W1-7 C1-8 C7-8 C6-7 C5-6 C4-5 C3-4 C1-2 C2-3 TOP CHORD TOP CHORD 8 7 6 5 4 1 2 3 BOTTOM CHORDS TOP CHORDS BEARING LATERAL BRACING LOCATION Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. The first dimension is the plate width measured perpendicular to slots. Second dimension is the length parallel to slots. 4 x 4 PLATE SIZE This symbol indicates the required direction of slots in connector plates. / 16 " 1 For 4 x 2 orientation, locate plates 0- Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 1 " / 4 3 PLATE LOCATION AND ORIENTATION Symbols Numbering System 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. Failure to Follow Could Cause Property Damage or Personal Injury General Safety Notes * Plate location details available in MiTek 20/20 software or upon request. Industry Standards: 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) © 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015 WEBS edge of truss. / 16 " from outside 1 0 - ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. W4-6 W3-6 W3-7 W2-7 W1-7 C1-8 C7-8 C6-7 C5-6 C4-5 C3-4 C1-2 C2-3 TOP CHORD TOP CHORD 8 7 6 5 4 1 2 3 BOTTOM CHORDS TOP CHORDS BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. 4 x 4 PLATE SIZE This symbol indicates the required direction of slots in connector plates. / 16 " 1 For 4 x 2 orientation, locate plates 0- 1 " / 4 3 PLATE LOCATION AND ORIENTATION Symbols Numbering System General Safety Notes * Plate location details available in MiTek 20/20 software or upon request. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths WEBS Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 11-6-14. (lb) - Max Horz 1=221(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=348(LC 1), 7=308(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-264/119 NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 7. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=150/9-0-14, 4=113/9-0-14, 5=421/9-0-14 Max Horz 1=172(LC 5) Max Uplift4=-23(LC 5), 5=-105(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-316/146 NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=105. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=37/6-6-14, 4=127/6-6-14, 5=326/6-6-14 Max Horz 1=123(LC 5) Max Uplift1=-20(LC 4), 4=-19(LC 5), 5=-84(LC 6) Max Grav 1=64(LC 5), 4=127(LC 1), 5=326(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-14 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=145/4-0-14, 3=145/4-0-14 Max Horz 1=73(LC 5) Max Uplift3=-25(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-6-14 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=45/1-6-14, 3=45/1-6-14 Max Horz 1=23(LC 5) Max Uplift3=-8(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-12 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=84/2-6-12, 3=84/2-6-12 Max Horz 1=43(LC 5) Max Uplift3=-14(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-12 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=184/5-0-12, 3=184/5-0-12 Max Horz 1=93(LC 5) Max Uplift3=-32(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=88/7-6-12, 4=123/7-6-12, 5=358/7-6-12 Max Horz 1=143(LC 5) Max Uplift1=-8(LC 4), 4=-22(LC 5), 5=-92(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-268/158 NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=181/10-0-12, 4=95/10-0-12, 5=482/10-0-12 Max Horz 1=190(LC 5) Max Uplift4=-29(LC 5), 5=-124(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-341/159 NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=124. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 0-0-4 8-4-8 8.00 12 Plate Offsets (X,Y)-- [9:0-3-14,Edge], [10:Edge,0-2-8], [18:0-0-2,0-1-4], [20:0-0-2,0-1-4], [21:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.41 0.22 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 101 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 9-10 REACTIONS. All bearings 12-6-12. (lb) - Max Horz 1=241(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17 Max Grav All reactions 250 lb or less at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 11, 12, 13, 14, 15, 16, 17. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 0.12 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-9 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=107/5-2-15, 3=107/5-2-15, 4=163/5-2-15 Max Horz 1=-46(LC 4) Max Uplift1=-16(LC 7), 3=-19(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=180/8-5-15, 3=180/8-5-15, 4=274/8-5-15 Max Horz 1=77(LC 5) Max Uplift1=-26(LC 7), 3=-32(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 BC WB (Matrix) 0.32 0.08 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SP No.1 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 11-8-5. (lb) - Max Horz 1=-107(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-101(LC 6), 6=-101(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=258(LC 1), 8=278(LC 10), 6=278(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=101, 6=101. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 BC WB (Matrix) 0.34 0.10 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SP No.1 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 14-10-12. (lb) - Max Horz 1=-138(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-116(LC 6), 6=-116(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=324(LC 10), 6=324(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=116 , 6=116. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=104/3-0-0, 3=104/3-0-0 Max Horz 1=65(LC 5) Max Uplift3=-23(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-3 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=168/4-7-3, 3=168/4-7-3 Max Horz 1=106(LC 5) Max Uplift3=-37(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=17/6-2-6, 4=127/6-2-6, 5=321/6-2-6 Max Horz 1=146(LC 5) Max Uplift1=-43(LC 4), 4=-34(LC 5), 5=-113(LC 6) Max Grav 1=95(LC 5), 4=127(LC 1), 5=321(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=113. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=101/7-9-9, 4=120/7-9-9, 5=371/7-9-9 Max Horz 1=186(LC 5) Max Uplift1=-27(LC 4), 4=-41(LC 5), 5=-131(LC 6) Max Grav 1=115(LC 5), 4=120(LC 1), 5=371(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-278/200 NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=131. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=154/7-4-1, 3=154/7-4-1, 4=234/7-4-1 Max Horz 1=-65(LC 4) Max Uplift1=-22(LC 7), 3=-27(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SP No.1 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=195/10-6-7, 3=195/10-6-7, 4=392/10-6-7 Max Horz 1=-96(LC 4) Max Uplift1=-12(LC 6), 3=-17(LC 7), 4=-4(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 Horz: 1-14=13, 7-8=16 Concentrated Loads (lb) Vert: 13=-1003(B) 10) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-8, 8-14=-12 Horz: 1-14=-16, 7-8=-13 Concentrated Loads (lb) Vert: 13=-1003(B) 11) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-8, 8-14=-12 Horz: 1-14=-16, 7-8=16 Concentrated Loads (lb) Vert: 13=-1003(B) 12) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-104, 8-14=-12 Horz: 1-14=-16, 7-8=16 Concentrated Loads (lb) Vert: 13=-1003(B) 13) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-7=-144, 8-14=-12 Horz: 1-14=-16, 7-8=16 Concentrated Loads (lb) Vert: 13=-1003(B) 14) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Continued on page 3 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.93 0.50 0.98 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.56 0.10 (loc) 10-12 10-12 8 l/defl >999 >484 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 515 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x6 SP No.1 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SP No.1 *Except* 2-13,3-12,4-10,6-9: 2x4 SPF-S Stud BRACING- TOP CHORD 2-0-0 oc purlins (4-9-8 max.): 1-7, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 14=14892/0-3-8 (req. 0-4-2), 8=10723/Mechanical Max Horz 14=-71(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=-14044/0, 1-2=-12238/0, 2-3=-12238/0, 3-4=-24931/0, 4-5=-24931/0, 5-6=-24931/0, 6-7=-875/3, 7-8=-2121/0 BOT CHORD 13-14=-44/526, 12-13=0/23945, 11-12=0/23945, 10-11=0/23945, 9-10=0/17553, 8-9=0/17553 WEBS 1-13=0/17756, 2-13=-3404/21, 3-13=-12963/0, 3-12=0/325, 3-10=-196/1097, 4-10=-4210/0, 6-10=0/8214, 6-8=-18566/0 NOTES- (12-13) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 4 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 2-13 2x4 - 2 rows staggered at 0-4-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) WARNING: Required bearing size at joint(s) 14 greater than input bearing size. 8) Refer to girder(s) for truss to truss connections. 9) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 5163 lb down and 17 lb up at 2-4-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-7=-889, 8-14=-20 Concentrated Loads (lb) Vert: 13=-5163(B) Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 Horz: 1-6=13, 3-4=16 Concentrated Loads (lb) Vert: 7=-154(F) 8=-152(F) 9=-152(F) 10=-152(F) 10) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-9, 4-6=-12 Horz: 1-6=-16, 3-4=-13 Concentrated Loads (lb) Vert: 7=-154(F) 8=-152(F) 9=-152(F) 10=-152(F) 11) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-9, 4-6=-12 Horz: 1-6=-16, 3-4=16 Concentrated Loads (lb) Vert: 7=-154(F) 8=-152(F) 9=-152(F) 10=-152(F) 12) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-103, 4-6=-12 Horz: 1-6=-16, 3-4=16 Concentrated Loads (lb) Vert: 7=-154(F) 8=-152(F) 9=-152(F) 10=-152(F) 13) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 3rd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=-143, 4-6=-12 Horz: 1-6=-16, 3-4=16 Concentrated Loads (lb) Vert: 7=-154(F) 8=-152(F) 9=-152(F) 10=-152(F) 14) Reversal: Dead + 0.6 MWFRS Wind (Pos. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Continued on page 3 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.08 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud *Except* 1-5,3-5: 2x4 SP No.1 BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-3, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 6=5183/Mechanical, 4=5064/0-5-8 Max Horz 6=-73(LC 3) Max Uplift6=-5(LC 3), 4=-1(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-4393/0, 1-2=-4626/13, 2-3=-4626/13, 3-4=-4393/0 WEBS 1-5=-14/5506, 2-5=-4099/0, 3-5=-14/5506 NOTES- (11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. 8) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 795 lb down and 35 lb up at 0-11-4, 793 lb down and 36 lb up at 2-11-4, and 793 lb down and 36 lb up at 4-11-4, and 793 lb down and 36 lb up at 6-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-878, 4-6=-20 Concentrated Loads (lb) Vert: 7=-795(F) 8=-793(F) 9=-793(F) 10=-793(F) Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.16 0.10 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 0.01 (loc) 6 6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=74/Mechanical, 7=229/0-3-8, 5=66/Mechanical Max Horz 7=90(LC 5) Max Uplift4=-31(LC 3), 7=-43(LC 5), 5=-13(LC 5) Max Grav 4=74(LC 1), 7=229(LC 1), 5=81(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 7, 5. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 31 lb down and 17 lb up at 1-5-3, and 37 lb down and 26 lb up at 2-0-12 on top chord, and 1 lb up at 1-5-3, and 2 lb down and 17 lb up at 2-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=1(F) 9=1(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.14 0.08 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.01 (loc) 6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 4=83/Mechanical, 7=193/0-3-8, 5=50/Mechanical Max Horz 7=74(LC 5) Max Uplift4=-33(LC 3), 7=-40(LC 5) Max Grav 4=83(LC 10), 7=193(LC 1), 5=73(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 7. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 37 lb down and 117 lb up at 0-9-10, and 1 lb down and 17 lb up at 2-0-12 on top chord, and 16 lb up at 0-9-10, and 2 lb up at 2-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 3=39(B) 6=7(B) 9=1(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 3-9-4 14-10-8 3-9-4 17-4-0 2-5-8 20-1-0 2-9-0 21-1-8 1-0-8 0-11-0 4-7-0 1-1-5 4-7-0 6.00 12 8.00 12 Plate Offsets (X,Y)-- [6:0-3-12,0-2-0], [17:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.88 0.25 0.52 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.04 -0.08 0.02 (loc) 13 13-14 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 122 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins, except end verticals, and 2-0-0 oc purlins (5-5-15 max.): 4-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=1140/0-3-8, 10=1172/0-3-8 Max Horz 17=112(LC 4) Max Uplift17=-324(LC 5), 10=-381(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1557/483, 3-4=-1452/533, 4-18=-1274/500, 5-18=-1273/500, 5-19=-1064/433, 6-19=-1065/433, 6-7=-1278/487, 7-8=-1231/422, 2-17=-1027/335, 8-10=-1084/377 BOT CHORD 17-20=-185/406, 16-20=-185/406, 15-16=-446/1338, 14-15=-446/1338, 14-21=-496/1330, 13-21=-496/1330, 13-22=-496/1330, 12-22=-496/1330, 12-23=-285/972, 11-23=-285/972 WEBS 4-14=-77/346, 5-12=-438/194, 6-12=-113/414, 2-16=-287/944, 8-11=-256/850 NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 17 = 0% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 17=324, 10=381. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 61 lb down and 80 lb up at 7-4-0, 56 lb down and 80 lb up at 9-2-0, 56 lb down and 80 lb up at 11-2-0, and 56 lb down and 80 lb up at 13-2-0, and 61 lb down and 80 lb up at 14-10-8 on top chord, and 34 lb down at 2-0-12, 38 lb down and 20 lb up at 4-0-12, 82 lb down and 77 lb up at 6-0-12, 34 lb down and 13 lb up at 7-4-12, 34 lb down and 13 lb up at 9-2-0, 34 lb down and 13 lb up at 11-2-0, 34 lb down and 13 lb up at 13-2-0, 34 lb down and 13 lb up at 14-9-12, and 69 lb down and 61 lb up at 16-0-4, and 46 lb down and 25 lb up at 18-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-6=-60, 6-8=-60, 8-9=-60, 10-17=-20 Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.78 0.28 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.01 (loc) 9-10 9-10 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 181 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=2750/0-3-8, 7=2528/0-5-8 Max Horz 11=177(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2739/0, 3-4=-2070/0, 4-5=-2072/0, 5-6=-2584/0, 2-11=-2368/0, 6-7=-2163/0 BOT CHORD 11-12=-72/384, 10-12=-72/384, 10-13=0/2031, 13-14=0/2031, 9-14=0/2031, 9-15=0/1915, 8-15=0/1915, 8-16=0/386, 7-16=0/386 WEBS 4-9=0/2342, 5-9=-545/0, 5-8=0/595, 3-9=-724/0, 3-10=0/839, 2-10=0/1710, 6-8=0/1586 NOTES- (7-8) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 765 lb down at 2-0-12, 765 lb down at 4-0-12, 765 lb down at 6-0-12, 765 lb down at 8-0-12, and 582 lb down at 10-0-12, and 496 lb down at 12-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-6=-60, 7-11=-20 Concentrated Loads (lb) Vert: 8=-582(F) 12=-765(F) 13=-765(F) 14=-765(F) 15=-765(F) 16=-496(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.72 0.50 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.08 0.01 (loc) 7-8 7-8 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 269 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=4132/0-5-8, 5=3952/0-5-8 Max Horz 8=-211(LC 3) Max Uplift8=-189(LC 6), 5=-171(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3235/221, 2-3=-3155/227, 3-4=-4534/232, 1-8=-3278/183, 4-5=-3663/181 BOT CHORD 7-12=-112/3398, 12-13=-112/3398, 6-13=-112/3398, 6-14=-57/579, 5-14=-57/579 WEBS 2-7=-186/3705, 3-7=-1515/162, 3-6=-68/1823, 1-7=-138/2485, 4-6=-101/2895 NOTES- (8-9) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=189, 5=171. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 445 lb down and 18 lb up at 0-7-4, 439 lb down and 21 lb up at 2-7-4, 1525 lb down and 70 lb up at 4-7-4, 1525 lb down and 70 lb up at 6-7-4, and 1525 lb down and 70 lb up at 8-7-4, and 1525 lb down and 70 lb up at 10-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 5-8=-20 Concentrated Loads (lb) Vert: 9=-445(F) 10=-439(F) 11=-1525(F) 12=-1525(F) 13=-1525(F) 14=-1525(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.61 0.17 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.01 (loc) 8 8-10 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 109 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-11,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=813/0-3-8, 6=813/Mechanical Max Horz 11=238(LC 5) Max Uplift11=-25(LC 6), 6=-24(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-901/99, 2-3=-681/166, 3-4=-677/167, 4-5=-864/100, 1-11=-755/80, 5-6=-757/79 BOT CHORD 10-11=-228/271, 9-10=-60/616, 8-9=-60/616, 7-8=0/590 WEBS 2-8=-269/133, 3-8=-103/452, 1-10=0/446, 5-7=0/470 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 6. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.61 0.18 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.01 (loc) 8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 110 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-11,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=825/0-3-8, 6=825/0-3-8 Max Horz 11=-235(LC 4) Max Uplift11=-26(LC 6), 6=-26(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-916/100, 2-3=-697/166, 3-4=-697/166, 4-5=-916/100, 1-11=-767/81, 5-6=-767/81 BOT CHORD 10-11=-225/271, 9-10=-55/627, 8-9=-55/627, 7-8=0/627 WEBS 3-8=-102/467, 4-8=-267/132, 2-8=-267/133, 1-10=0/456, 5-7=0/456 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 6. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.61 0.18 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.01 (loc) 9 9-11 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-12,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12=823/0-3-8, 7=896/0-3-8 Max Horz 12=-250(LC 4) Max Uplift12=-26(LC 6), 7=-61(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-913/100, 2-3=-694/167, 3-4=-694/166, 4-5=-910/102, 1-12=-765/81, 5-7=-838/119 BOT CHORD 11-12=-214/285, 10-11=-44/625, 9-10=-44/625, 8-9=0/621 WEBS 3-9=-101/466, 4-9=-262/132, 2-9=-267/132, 1-11=0/454, 5-8=0/482 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 7. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.28 0.13 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.02 -0.04 (loc) 6-7 6-7 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 4=52/Mechanical, 7=231/0-3-8, 5=89/Mechanical Max Horz 7=133(LC 6) Max Uplift4=-5(LC 5), 5=-49(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.29 0.13 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.02 -0.04 (loc) 6-7 6-7 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 4=39/Mechanical, 7=231/0-3-8, 5=102/Mechanical Max Horz 7=137(LC 6) Max Uplift4=-3(LC 4), 5=-65(LC 6) Max Grav 4=46(LC 2), 7=231(LC 1), 5=102(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.23 0.15 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.02 0.04 (loc) 6 6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 4=83/Mechanical, 7=231/0-3-8, 5=58/Mechanical Max Horz 7=106(LC 6) Max Uplift4=-23(LC 5), 7=-18(LC 6), 5=-8(LC 6) Max Grav 4=83(LC 1), 7=231(LC 1), 5=66(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 7, 5. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.67 0.23 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.09 0.02 (loc) 10-11 10-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 97 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 2-13,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-10 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=860/0-3-8, 8=863/0-3-8 Max Horz 13=169(LC 5) Max Uplift13=-78(LC 6), 8=-64(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1141/142, 3-4=-772/147, 4-5=-797/159, 5-6=-938/118, 2-13=-794/167, 6-8=-810/134 BOT CHORD 12-13=-131/323, 11-12=-131/323, 10-11=-42/950, 9-10=0/717 WEBS 3-10=-412/114, 4-10=-40/432, 2-11=-6/631, 6-9=-3/596 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 8. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 6-3-0 1-1-5 6-3-0 6.00 12 8.00 12 Plate Offsets (X,Y)-- [4:0-4-8,0-1-12], [5:0-3-12,0-2-0], [15:Edge,0-7-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.56 0.22 0.35 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.09 0.02 (loc) 12-13 12-13 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 104 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 2-15,7-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 15=860/0-3-8, 9=863/0-3-8 Max Horz 15=157(LC 5) Max Uplift15=-76(LC 6), 9=-62(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1145/142, 3-4=-819/149, 4-5=-632/154, 5-6=-819/155, 6-7=-931/114, 2-15=-798/164, 7-9=-814/130 BOT CHORD 14-15=-127/279, 13-14=-127/279, 12-13=-43/959, 11-12=0/672, 10-11=0/718 WEBS 3-12=-357/102, 4-12=-6/288, 5-11=-49/292, 2-13=-19/685, 7-10=-12/628 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 9. 6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 8.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [4:0-3-11,0-2-8], [7:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.56 0.38 0.74 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.17 0.03 (loc) 12-13 12-13 7 l/defl >999 >575 n/a L/d 240 180 n/a PLATES MT20 Weight: 135 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-13: 2x4 SP No.1 WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 6-9, 1-12 REACTIONS. All bearings 11-3-8 except (jt=length) 7=0-3-8, 11=0-3-8. (lb) - Max Horz 13=232(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 13, 12, 7 Max Grav All reactions 250 lb or less at joint(s) 11 except 13=340(LC 10), 12=1129(LC 1), 7=857(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-643/176, 4-5=-478/186, 5-6=-684/145, 6-7=-1196/139, 1-13=-255/85 BOT CHORD 12-13=-214/253, 8-9=-24/882, 7-8=-24/882 WEBS 3-12=-977/205, 3-9=0/486, 6-9=-522/148, 6-8=0/309 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 12, 7. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 38-11-0 6-10-14 6-8-0 6-8-0 13-1-8 6-5-8 19-7-0 6-5-8 25-1-7 5-6-7 32-0-2 6-10-11 38-11-0 6-10-14 2-1-2 14-7-13 0-7-9 4-9-14 6.00 12 8.00 12 3.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-12], [6:0-3-11,0-2-8], [9:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.69 0.52 0.84 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.52 0.25 (loc) 13-15 13-15 9 l/defl >999 >894 n/a L/d 240 180 n/a PLATES MT20 Weight: 182 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-17: 2x4 SP No.1 WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-13 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 9-4-4 oc bracing. WEBS 1 Row at midpt 5-11, 8-11 REACTIONS. (lb/size) 17=1545/0-3-8, 9=1545/Mechanical Max Horz 17=339(LC 5) Max Uplift17=-79(LC 6), 9=-58(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2817/395, 2-3=-3046/415, 3-4=-2890/446, 4-5=-2591/399, 5-6=-1714/327, 6-7=-1753/336, 7-8=-1872/294, 8-9=-2364/287, 1-17=-1511/247 BOT CHORD 16-17=-339/200, 15-16=-454/2531, 14-15=-386/2725, 13-14=-377/2745, 12-13=-209/2220, 11-12=-209/2220, 10-11=-145/1828, 9-10=-145/1828 WEBS 2-16=-545/149, 4-13=-505/177, 5-13=-107/997, 5-11=-1213/259, 6-11=-197/1338, 8-11=-487/151, 8-10=0/306, 1-16=-226/2259 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 9. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 9-9-15 0-7-9 6.00 12 8.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [4:0-3-6,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.58 0.36 0.55 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.02 (loc) 11-13 11-13 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 146 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-14: 2x4 SP No.1 WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 10-11. WEBS 1 Row at midpt 3-11, 4-11, 5-10 REACTIONS. (lb/size) 14=733/0-3-8, 10=1178/0-3-8, 8=459/Mechanical Max Horz 14=232(LC 5) Max Uplift14=-43(LC 6), 10=-61(LC 7), 8=-9(LC 7) Max Grav 14=735(LC 10), 10=1178(LC 1), 8=459(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-865/103, 2-3=-671/126, 3-4=-334/131, 7-8=-562/53, 1-14=-653/121 BOT CHORD 13-14=-222/258, 12-13=-113/681, 11-12=-113/681, 9-10=0/384, 8-9=0/384 WEBS 3-13=0/277, 3-11=-594/168, 5-11=-20/591, 5-10=-845/101, 7-10=-443/127, 7-9=0/257, 1-13=0/431 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10, 8. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 2-3-5 23-9-0 5-4-4 29-3-11 5-6-12 1-9-4 9-9-15 1-0-7 6.00 12 8.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [4:0-3-6,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.58 0.37 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.18 0.02 (loc) 12-14 12-14 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 150 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-15: 2x4 SP No.1, 8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 4-12, 5-11 REACTIONS. (lb/size) 15=749/0-3-8, 11=1111/0-3-8, 9=462/0-3-8 Max Horz 15=242(LC 5) Max Uplift15=-46(LC 6), 11=-45(LC 7), 9=-16(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-886/112, 2-3=-693/135, 3-4=-358/142, 4-5=-259/167, 7-8=-343/104, 1-15=-667/126, 8-9=-297/104 BOT CHORD 14-15=-232/258, 13-14=-113/700, 12-13=-113/700, 10-11=0/347, 9-10=0/347 WEBS 3-14=0/273, 3-12=-590/166, 5-12=-12/565, 5-11=-795/78, 6-11=-375/117, 1-14=0/450 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 11, 9. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [4:0-3-6,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.71 0.37 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.19 0.02 (loc) 7-8 9-11 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 147 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-12,6-7,5-7: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9, 4-9, 5-8, 5-7 REACTIONS. (lb/size) 12=786/0-3-8, 8=878/0-3-8, 7=454/0-3-8 Max Horz 12=262(LC 5) Max Uplift12=-54(LC 6), 8=-6(LC 6), 7=-33(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-948/136, 2-3=-754/159, 3-4=-427/169, 4-5=-388/223, 5-6=-348/210, 1-12=-704/141, 6-7=-368/176 BOT CHORD 11-12=-252/258, 10-11=-114/755, 9-10=-114/755 WEBS 3-11=0/269, 3-9=-586/163, 5-9=-79/464, 5-8=-762/129, 1-11=0/506 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8, 7. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.93 0.37 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.16 0.02 (loc) 9-10 9-10 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 113 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-10: 2x4 SP No.1, 5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS. (lb/size) 10=912/0-3-8, 6=912/0-3-8 Max Horz 10=292(LC 5) Max Uplift10=-48(LC 6), 6=-45(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1145/139, 2-3=-951/162, 3-4=-671/173, 4-5=-703/181, 1-10=-827/143, 5-6=-846/137 BOT CHORD 9-10=-274/274, 8-9=-107/930, 7-8=-107/930 WEBS 3-7=-549/158, 4-7=-5/286, 1-9=0/667, 5-7=-26/571 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix-S) 0.82 0.39 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.19 0.02 (loc) 9-10 9-10 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 112 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-10,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 3-7 REACTIONS. (lb/size) 10=912/0-3-8, 6=912/0-3-8 Max Horz 10=291(LC 5) Max Uplift10=-48(LC 6), 6=-44(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1150/137, 2-3=-960/161, 3-4=-664/170, 4-5=-692/176, 1-10=-835/140, 5-6=-853/134 BOT CHORD 9-10=-270/164, 8-9=-107/944, 7-8=-107/944 WEBS 3-7=-570/166, 1-9=-14/795, 5-7=-13/579, 4-7=-6/280 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. 5) This truss design requires that a minimum of 7/16” structural wood sheathing be applied directly to the top chord and ½” gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.83 0.27 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.10 0.02 (loc) 8-10 8-10 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 118 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-11,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-12 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS. (lb/size) 11=912/0-3-8, 6=912/0-3-8 Max Horz 11=248(LC 5) Max Uplift11=-41(LC 6), 6=-18(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1131/159, 2-3=-862/179, 3-4=-430/155, 4-5=-570/153, 1-11=-843/133, 5-6=-874/123 BOT CHORD 9-10=-155/938, 8-9=-155/938, 7-8=-123/702 WEBS 2-8=-302/114, 3-8=0/387, 3-7=-462/79, 1-10=-24/795, 5-7=-69/648 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 6. 6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.52 0.25 0.60 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.10 0.02 (loc) 9-10 9-10 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 120 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-13,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-14 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9 REACTIONS. (lb/size) 13=912/0-3-8, 7=912/0-3-8 Max Horz 13=206(LC 5) Max Uplift13=-29(LC 6), 7=-81(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1066/148, 2-3=-1005/177, 3-4=-807/171, 4-5=-807/171, 5-6=-306/120, 1-13=-856/123, 6-7=-901/116 BOT CHORD 11-12=-184/897, 10-11=-184/897, 9-10=-172/853, 8-9=-74/255 WEBS 4-9=-390/158, 5-9=-128/785, 5-8=-660/194, 1-12=-48/838, 6-8=-122/783 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 7. 6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.63 0.46 0.42 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.23 0.06 (loc) 9-11 9-11 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 135 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-12: 2x4 SP No.1 WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-4 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9, 6-9 REACTIONS. (lb/size) 12=1185/0-3-8, 7=1185/0-3-8 Max Horz 12=232(LC 5) Max Uplift12=-59(LC 6), 7=-47(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1587/184, 2-3=-1393/207, 3-4=-1181/224, 4-5=-1050/238, 5-6=-1256/196, 6-7=-1749/192, 1-12=-1099/171 BOT CHORD 11-12=-214/285, 10-11=-94/1324, 9-10=-94/1324, 8-9=-66/1329, 7-8=-66/1329 WEBS 3-9=-497/152, 4-9=-66/686, 6-9=-496/150, 6-8=0/296, 1-11=-21/1058 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 7. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 Plate Offsets (X,Y)-- [1:Edge,0-1-12], [3:0-5-0,0-2-0], [4:0-3-12,0-2-0], [6:0-3-8,Edge], [11:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.92 0.37 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.17 0.06 (loc) 10-11 10-11 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 140 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-9 oc purlins, except end verticals, and 2-0-0 oc purlins (5-10-10 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS. (lb/size) 12=1185/0-3-8, 6=1185/0-3-8 Max Horz 12=192(LC 5) Max Uplift12=-47(LC 6), 6=-38(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1548/200, 2-3=-1335/228, 3-4=-1073/222, 4-5=-1380/223, 5-6=-1777/184, 1-12=-1113/161 BOT CHORD 10-11=-99/1309, 9-10=-22/1119, 8-9=-22/1119, 7-8=-75/1358, 6-7=-75/1358 WEBS 2-10=-265/111, 3-10=0/346, 4-8=-15/424, 5-8=-364/126, 1-11=-58/1157 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 6. 6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 6-6-8 0-7-9 6-6-8 6.00 12 8.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [3:0-5-0,0-2-0], [5:0-4-4,0-2-4], [7:0-3-8,Edge], [13:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.59 0.42 0.40 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.15 0.06 (loc) 10 9-10 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 141 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-14: 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-0-12 max.): 3-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 14=1185/0-3-8, 7=1185/0-3-8 Max Horz 14=150(LC 5) Max Uplift14=-31(LC 6), 7=-26(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1445/185, 2-3=-1454/223, 3-4=-1438/235, 4-5=-1439/235, 5-6=-1506/209, 6-7=-1786/176, 1-14=-1125/150 BOT CHORD 12-13=-122/1234, 11-12=-107/1250, 10-11=-107/1250, 9-10=-22/1199, 8-9=-82/1364, 7-8=-82/1364 WEBS 2-13=-287/86, 3-10=-60/370, 4-10=-359/156, 5-10=-127/431, 5-9=0/299, 1-13=-79/1173 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 7. 6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.21 0.11 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 83 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-11,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=547/0-5-8, 7=622/0-5-8 Max Horz 11=-228(LC 4) Max Uplift11=-26(LC 7), 7=-50(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-369/95, 2-3=-369/138, 3-4=-400/131, 4-5=-563/80, 1-11=-513/62, 5-7=-577/102 BOT CHORD 8-9=0/372 WEBS 1-10=0/318, 5-8=0/307 NOTES- (5-6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 8-0-1 1-3-0 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.20 0.11 0.41 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.01 (loc) 8 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 86 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-11,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7=622/0-5-8, 11=547/0-5-8 Max Horz 11=-228(LC 4) Max Uplift7=-50(LC 7), 11=-26(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-373/141, 3-4=-402/132 BOT CHORD 8-9=0/374, 7-8=0/374 WEBS 4-7=-453/0, 2-11=-485/0 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 11. 5) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.65 0.20 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.06 0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 76 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-9,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9=547/0-5-8, 6=622/0-5-8 Max Horz 9=-190(LC 4) Max Uplift9=-9(LC 7), 6=-49(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-409/110, 2-3=-333/130, 3-4=-554/98, 1-9=-506/77, 4-6=-555/123 BOT CHORD 7-8=-58/259 WEBS 1-8=-44/296 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 in -0.01 -0.04 0.00 (loc) 3-4 3-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=185/Mechanical, 4=185/0-3-8 Max Horz 4=118(LC 5) Max Uplift3=-40(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.04 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=176/Mechanical, 5=262/0-3-8 Max Horz 5=128(LC 5) Max Uplift4=-39(LC 6), 5=-28(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 TC BC WB (Matrix) 0.40 0.19 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.05 0.01 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=426/Mechanical, 7=502/0-3-8 Max Horz 7=197(LC 5) Max Uplift5=-62(LC 6), 7=-48(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-517/90, 2-7=-447/147 BOT CHORD 5-6=-53/402 WEBS 3-5=-459/159 NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 8-4-12 6-1-4 14-6-0 6-1-4 20-3-8 5-9-8 0-11-0 11-0-12 9-1-12 11-0-12 0-8-0 6.00 12 Plate Offsets (X,Y)-- [8:0-4-0,0-3-0], [11:0-3-8,0-2-0], [13:0-4-8,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.40 0.49 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.17 0.18 (loc) 12-13 12-13 18 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 127 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 8-11,8-9: 2x4 SP No.1, 2-16: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-2 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 7-10-8 oc bracing: 12-13. WEBS 1 Row at midpt 7-10 REACTIONS. (lb/size) 16=870/0-3-8, 18=773/0-3-8 Max Horz 16=340(LC 6) Max Uplift16=-20(LC 6), 18=-153(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-715/1, 3-4=-1713/313, 4-5=-1195/11, 5-6=-1091/29, 6-7=-613/0, 7-8=-628/114, 2-16=-806/76 BOT CHORD 15-16=-336/115, 12-13=-635/1634, 11-12=-262/1001 WEBS 7-11=-397/194, 3-15=-764/218, 13-15=-379/681, 3-13=-351/1149, 4-12=-641/377, 6-12=0/356, 6-11=-637/164, 8-11=-260/971, 2-15=0/538, 8-18=-779/195 NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 18 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 16 and 153 lb uplift at joint 18. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.91 0.29 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.13 0.15 (loc) 8-9 8-9 13 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 110 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 6-7: 2x4 SP No.1, 2-11: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-14 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-7 REACTIONS. (lb/size) 11=871/0-3-8, 13=775/0-3-8 Max Horz 11=319(LC 5) Max Uplift11=-51(LC 6), 13=-120(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1145/94, 3-4=-674/62, 4-5=-514/94, 7-12=-77/639, 6-12=-77/639, 2-11=-798/147 BOT CHORD 10-11=-257/415, 9-10=-257/415, 8-9=-121/943, 7-8=-70/527 WEBS 3-8=-486/138, 5-8=-26/461, 5-7=-756/186, 2-9=0/531, 6-13=-793/150 NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except (jt=lb) 13=120. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 (Matrix) 0.13 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=45/Mechanical, 5=205/0-5-10, 4=20/Mechanical Max Horz 5=56(LC 6) Max Uplift3=-25(LC 6), 5=-40(LC 6) Max Grav 3=45(LC 1), 5=205(LC 1), 4=43(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=165/0-3-8, 3=38/Mechanical, 4=17/Mechanical Max Horz 5=85(LC 6) Max Uplift5=-11(LC 6), 3=-32(LC 6), 4=-6(LC 6) Max Grav 5=165(LC 1), 3=38(LC 1), 4=36(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.01 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-4-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=-47/Mechanical, 4=2/Mechanical, 5=272/0-5-9 Max Horz 5=71(LC 6) Max Uplift3=-47(LC 1), 4=-10(LC 6), 5=-80(LC 6) Max Grav 3=17(LC 6), 4=22(LC 2), 5=272(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4, 5. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=161/0-3-8, 3=39/Mechanical, 4=17/Mechanical Max Horz 5=63(LC 6) Max Uplift5=-27(LC 6), 3=-22(LC 6) Max Grav 5=161(LC 1), 3=39(LC 1), 4=36(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.03 -0.04 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=229/0-3-8, 3=102/Mechanical, 4=42/Mechanical Max Horz 5=154(LC 6) Max Uplift3=-81(LC 6), 4=-1(LC 6) Max Grav 5=229(LC 1), 3=102(LC 1), 4=74(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (5-6) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 5) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 6) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.65 0.27 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.05 -0.11 0.06 (loc) 5-6 5-6 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-5 REACTIONS. (lb/size) 7=516/Mechanical, 8=522/0-3-8 Max Horz 7=291(LC 5) Max Uplift8=-100(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-7=-451/75, 1-2=-547/54, 2-3=-354/76, 5-8=-43/360 BOT CHORD 6-7=-267/271, 5-6=-90/374 WEBS 3-6=0/270, 3-5=-472/145 NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.96 0.33 0.46 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.08 -0.15 0.21 (loc) 5-6 5-6 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 88 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-5 REACTIONS. (lb/size) 7=602/Mechanical, 8=611/0-3-8 Max Horz 7=335(LC 5) Max Uplift8=-115(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-7=-525/82, 1-2=-649/56, 2-3=-423/82, 5-8=-50/414 BOT CHORD 6-7=-312/334, 5-6=-99/443 WEBS 3-6=0/314, 3-5=-540/165 NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=115. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.82 0.39 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.06 -0.11 0.57 (loc) 6-7 7-8 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 131 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 5-6,4-6: 2x4 SP No.1 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-7, 4-6 REACTIONS. (lb/size) 10=785/Mechanical, 12=762/0-3-8 Max Horz 10=356(LC 5) Max Uplift12=-185(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-715/0, 1-2=-929/0, 2-3=-564/0, 3-4=-370/17, 6-11=-107/625, 5-11=-107/625 BOT CHORD 9-10=-330/289, 8-9=-330/289, 7-8=-127/684, 6-7=-92/382 WEBS 1-8=0/435, 2-7=-394/145, 4-7=-64/452, 4-6=-660/198, 5-12=-764/186 NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=185. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 20-11-0 20-11-0 -1-0-0 1-0-0 10-5-8 10-5-8 20-11-0 10-5-8 21-11-0 1-0-0 1-3-0 9-11-9 1-3-0 10.00 12 Plate Offsets (X,Y)-- [33:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.29 0.12 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 19 19 20 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 376 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 10-28, 9-29, 11-27 REACTIONS. All bearings 20-11-0. (lb) - Max Horz 37=238(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 30, 31, 32, 34, 35, 26, 25, 24, 23, 22 except 37=-196(LC 4), 20=-145(LC 5), 36=-216(LC 5), 21=-182(LC 4) Max Grav All reactions 250 lb or less at joint(s) 20, 28, 29, 30, 31, 32, 34, 35, 36, 27, 26, 25, 24, 23, 22, 21 except 37=275(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30, 31, 32, 34, 35, 26, 25, 24, 23, 22 except (jt=lb) 37=196, 20=145, 36=216, 21=182. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 13-8-8 6-10-4 14-8-8 1-0-0 1-3-0 6-11-9 1-3-0 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.19 0.08 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 194 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 13-8-8. (lb) - Max Horz 24=168(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 14, 20, 21, 22, 18, 17, 16 except 24=-105(LC 4), 23=-121(LC 5), 15=-107(LC 4) Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 20, 21, 22, 18, 17, 16 except (jt=lb) 24=105, 23=121, 15=107. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.37 0.41 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 123 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 9-4-12. (lb) - Max Horz 1=224(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 9, 10, 11, 12, 13 Max Grav All reactions 250 lb or less at joint(s) 1, 8, 9, 10, 11, 12, 13 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 9, 10, 11, 12, 13. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-11-2 19-7-0 19-7-0 19-1-6 19-1-6 19-7-0 0-5-10 1-3-5 14-0-4 8.00 12 Plate Offsets (X,Y)-- [7:0-2-12,0-3-4], [18:Edge,0-1-15] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.47 0.39 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 19 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 511 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 18-19: 2x4 SP No.1 OTHERS 2x3 SPF No.2 *Except* 17-19,16-20,15-21,14-22: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 17-18. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 18-19, 17-19, 16-20, 15-21, 14-22, 13-23, 12-24, 11-25 REACTIONS. All bearings 19-7-0. (lb) - Max Horz 34=413(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 32 except 34=-244(LC 4), 19=-111(LC 5), 33=-382(LC 6) Max Grav All reactions 250 lb or less at joint(s) 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 32, 33 except 34=498(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-34=-259/478, 2-3=-484/261, 3-4=-309/174, 4-5=-323/189, 5-6=-301/185, 6-7=-282/174, 7-8=-278/182, 8-9=-263/179, 18-19=-152/294 WEBS 3-33=-172/314, 2-34=-880/462 NOTES- (11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 32 except (jt=lb) 34=244, 19=111, 33=382. 9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 2x4 2x4 2x4 2x4 23-1-0 23-1-0 6-2-8 6-2-8 23-1-0 16-10-8 1-9-4 4-10-8 6.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-2-0], [34:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.21 0.07 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 22 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 333 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-21. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 23-1-0. (lb) - Max Horz 39=140(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 39, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36 except 38=-155(LC 5) Max Grav All reactions 250 lb or less at joint(s) 39, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-39=-256/52 NOTES- (10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 39, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36 except (jt=lb) 38=155. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 13-3-3 1-11-11 20-0-0 6-8-13 -1-0-0 1-0-0 6-8-13 6-8-13 11-3-8 4-6-11 13-3-3 1-11-11 20-0-0 6-8-13 0-11-0 10-11-0 6.00 12 Plate Offsets (X,Y)-- [14:0-1-8,0-0-12], [21:0-1-12,0-1-0], [24:0-1-12,0-1-0], [27:0-1-12,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.62 0.27 0.39 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.11 0.01 (loc) 7-8 7-8 7 l/defl >999 >909 n/a L/d 240 180 n/a PLATES MT20 Weight: 299 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 6-7: 2x4 SP No.1, 2-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-7, 5-7 REACTIONS. All bearings 11-3-8 except (jt=length) 7=Mechanical. (lb) - Max Horz 12=338(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 12, 10, 9 except 7=-126(LC 6) Max Grav All reactions 250 lb or less at joint(s) 9, 9 except 7=565(LC 1), 12=448(LC 1), 10=587(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-370/80, 4-5=-436/142, 2-12=-386/152 BOT CHORD 11-12=-253/255, 10-11=-253/255, 9-10=-253/255, 8-9=-253/255, 7-8=-113/313 WEBS 4-10=-464/128, 5-7=-441/198 NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 1-4-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 10, 9 except (jt=lb) 7=126. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 20-0-0 20-0-0 -1-0-0 1-0-0 20-0-0 20-0-0 0-11-0 10-11-0 6.00 12 Plate Offsets (X,Y)-- [31:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.32 0.35 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 1 1 19 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 378 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SPF-S Stud *Except* 18-19: 2x4 SP No.1 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 18-19, 17-20, 16-21, 15-22 REACTIONS. All bearings 20-0-0. (lb) - Max Horz 34=338(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 34, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31 except 33=-218(LC 5) Max Grav All reactions 250 lb or less at joint(s) 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 except 34=304(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-314/2, 3-4=-257/17, 4-5=-251/14 NOTES- (8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 34, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31 except (jt=lb) 33=218. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.07 0.04 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 24 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 403 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-20. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 29-11-0. (lb) - Max Horz 47=109(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 47, 29, 30, 31, 32, 33, 34, 35, 37, 38, 39, 40, 41, 24, 43, 44, 45, 46, 27, 26, 25 Max Grav All reactions 250 lb or less at joint(s) 47, 28, 29, 30, 31, 32, 33, 34, 35, 37, 38, 39, 40, 41, 24, 42, 43, 44, 45, 46, 27, 26, 25 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 47, 29, 30, 31, 32, 33, 34, 35, 37, 38, 39, 40, 41, 24, 43, 44, 45, 46, 27, 26, 25. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018 1-0-0 3-1-12 4-8-9 1-3-0 4-8-9 10.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-1-12], [9:0-4-4,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.21 0.10 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 195 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x3 SPF No.2 *Except* 12-14: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-9. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 14-0-8. (lb) - Max Horz 25=-151(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 25, 14, 17, 18, 19, 20, 21, 22, 23, 24, 16 except 15=-135(LC 4) Max Grav All reactions 250 lb or less at joint(s) 25, 14, 17, 18, 19, 20, 21, 22, 23, 24, 16, 15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 14, 17, 18, 19, 20, 21, 22, 23, 24, 16 except (jt=lb) 15=135. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. February 2,2018