Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A001 Abbreviations & General Notes
Hamilton Commercial and Residential Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date LGA, EJD, DJS Laurence Armstrong Carmel, Indiana 46032 #### SCALE: NTS PLAN NORTH KEY PLAN PARK EAST PEDCOR DESIGN GROUP LLC A001 Abbreviations & General Notes THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2017 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA. Construction Documents By: Friday, October 6, 2017, BIM Server: BIM20 - BIM Server 20/BLDG E/Building E Retail HOLLAND BUILDING, BUILDING G , CONSTRUCTION DOCUMENTS, A001 , BIM Server: PDGBIM - BIM Server 19/BLDG G/Building G , 8/20/16, 6:33 PM A: Area, Acre; Alcove; Compressed Air Line AB: Anchor Bolt ABV: Above AC: Air Conditioning, Alternating Current ACC: Access ACF: Architectural Concrete Finish ACR: Acrylic ACST: Acoustic ACT: Actual AD: Access Door, Area Drain ADA: Americans with Disabilities Act of 1992 ADD: Addendum; Addition ADDL: Additional ADH: Adhesive ADJ: Adjust, Adjustable, Adjacent AF: Above the Floor AFF: Above Finished Floor AIA: American Institute of Architects ALM: Alarm ALT: Alternate, Alteration; Altitude ALUM: Aluminum AMB: Ambient AMT: Amount ANCH: Anchor, Anchorage ANOD: Anodized AP: Access Panel APPROX: Approximate APRVD: Approved APT: Apartment ARCH: Architect, Architectural AS: Acoustic Sealant ASC: Above Suspended Ceiling ASPH: Asphalt ASSEM: Assemble ASSY: Assembly ASTM: American Society for Testing and Materials ATC: Acoustical Tile Ceiling ATTEN: Attenuation, Attention ATM: Automatic Teller Machine; Atmospheric AUTH: Authorized AUTO: Automatic AVG: Average B: Bathroom B TO B: Back to Back B & B: Balled and Burlapped B/: Bottom (of) BAL: Balance, Ballast BC: Broom Closet BDY: Boundary BEL: Below BETW: Between BEV: Bevel BHD: Bulkhead BIT: Bituminous BJF: Bituminous Joint Filler BL: Building Line BLDG: Building BLK: Block BLKG: Blocking BLT-IN: Built-In BM: Beam, Bench Mark BN: Bullnose BNT: Bent BOT: Bottom BP: Base Plate BPL: Bearing Plate BR: Bedroom BRDG: Bridging BRG: Bearing BRK: Brick BRKT: Bracket BRS: Brass BRZ: Bronze BS: Both Sides BSMT: Basement BT: Bathtub, Bolt BUR: Built-up Roof BW: Both Ways C: Curb, Clock Outlet C/C: Center to Center CAB: Cabinet CAP: Capacity CAR: Carpet CAV: Cavity CCW: Counter Clockwise CCTV: Closed Circuit TV CEM: Cement CER: Ceramic CF: Cubic Feet CFL: Counterflashing CFS: Cold Formed Steel CG: Corner Guard CH: Coat Hook CHR: Chilled Water Return CHAM: Chamfer CHAN: Channel CHS: Chilled Water Supply CI: Cast Iron CIP: Cast-in-Place CIR: Circle, Circular CIRC: Circumference CITG: Clear Insulating Tempered Glass CJ: Control Joint CK: Caulking CL: Centerline, Clearance, Closure, Class CLG: Ceiling CLL: Contract Limit Line CLO: Closet CLR: Clear CLR OPG: Clear Opening CMP: Corrugated Metal Pipe CMU: Concrete Masonry Unit CND: Conduit CNTR: Counter COAX: Coaxial C.O.: Cased Opening CO: Company, Cleanout, Cased Opening, Cut Out COD: Cleanout Door COL: Column COM: Common CON: Construction CONC: Concrete CONN: Connection CONT: Continuous, Continue, Control COP: Copper COR: Corner CORR: Corridor, Corrugate CR: Curtain Rod CRPT: Carpet CRS: Course, Cold Rolled Steel CS: Cast Stone CSG: Casing CSK: Countersink CSMT: Casement CT: Ceramic Tile CTD: Coated CTR: Center CW: Clockwise, Cold Water CWR: Condensate Waste Return CWS: Condensate Waste Supply CY: Cubic Yard CYL: Cylinder CYL L: Cylinder Lock DA: Double Acting DB: Decibel DBL: Double DC: Direct Current DD: Driveway Drain, Deck Drain DEG: Degree DEGF: Degree Farenheit DEMO: Demolition DEPT: Department DF: Drinking Fountain DH: Double Hung DIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: Dimension DISL: Disposal DIV: Division DL: Dead Load DMT: Demountable DN: Down DO: Door Opening DP: Dampproofing DPR: Damper DR: Door, Dining Room DS: Downspout DSP: Dry Standpipe DT: Drain Tile DTL: Detail DVTL: Dovetail DWG: Drawing DWGS: Drawings DWR: Drawer E: East E TO E: End to End EA: Each EB: Expansion Bolt EC: Exposed Construction ECP: Exposed Construction Painted EE: Each End EF: Each Face EG: Edge Grain EIFS: Exterior Insulation and Finish System EJ: Expansion Joint ELEC: Electrical ELEV: Elevator, Elevation EMER: Emergency ENAM: Enamel ENCL: Enclosure ENG: Engineer ENT: Entrance EPDM: Ethylene Propylene Diene Monomer EQ: Equal EQUIP: Equipment ERP: Emergency Receptacle Panel EST: Estimate EW: Each Way EX: Exit EXC: Excavate EXEC: Executive EXH: Exhaust EXH AIR: Exhaust Air EXIST: Existing EXP: Expansion, Exposed EXT: Exterior F: Degrees Fahrenheit F TO F: Face to Face FA: Fire Alarm, Fresh Air FAB: Fabricate FACP: Fire Alarm Control Panel FAG: Fire Alarm Gong FAST: Fastener, Fasten FBD: Fiberboard FBRK: Fire Brick FD: Floor drain FDC: Fire Department Connection FDN: Foundation FE: Fire Extinguisher FEC: Fire Extinguisher Cabinet FF: Finished Floor, Factory Finish FFE: Finished Floor Elevation FF&E: Fixtures, Furnishings & Equipment FFL: Finished Floor Line FGL: Fiberglass FGR: Fiberglass reinforced FH: Fire Hose FHC: Fire Hose Cabinet FHWS: Flat Head Wood Screw FHY: Fire Hydrant FIN: Finish, finished FIX: Fixture FLG: Flashing FLR: Floor FLUOR: Fluorescent FLX: Flexible FND: Feminine Napkin Dispenser FO: Finished Opening FOC: Face of Concrete FOF: Face of Finish FOS: Face of Studs FP: Fireproof FPL: Fireplace FR: Front, Fire Riser FRM: Frame FRT: Fire Retardant FS: Floor Sink FT: Foot, Feet, Fully Tempered FTG: Footing, Fitting FURN: Furnish, Furniture FURR: Furring FUT: Future G: Gas GA: Gauge GAL: Gallon GALV: Galvanized GC: General Contractor GEN: General GFCI: Ground Fault Circuit Interrupted GFI: Ground Fault Interrupted GFRC: Glass Fiber Reinforced Concrete GI: Galvanized Iron GKT: Gasket GL: Glass GLZ: Glaze GMU: Glazed Masonry Unit GND: Ground GOVT: Government GP: Galvanized Pipe GR: Grade GRAN: Granite GRTG: Grating GT: Grout GV: Galvanized GVL: Gravel GYP: Gypsum GYP BD: Gypsum Board HB: Hose Bib HBD: Hardboard HC: Hollow Core HD: Heavy Duty HDR: Header HDPE: High Density Polyethylene HDW: Hardware HDWD: Hardwood HGR: Hanger HGT: Height HK: Hook or Hooks HM: Hollow Metal HMP: Hollow Metal, Painted HOR: Horizontal HR: Hour HRS: Hot Rolled Steel, Hours HT: Height HTR: Heater HV: High Voltage HVAC: Heating, Ventilating & Air Conditioning HW: Hot Water HWR: Hot Water Recirculating Return HWS: Hot Water Supply HYD: Hydraulic I: Iron ID: Inside Diameter IN: Inch INC: Incandescent INCL: Incline, Include INCR: Increase INFO: Information INSP: Inspect INSTL: Install INSUL: Insulation INT: Interior INV: Invert IP: Iron Pipe J: Joist JB: Junction Box JC: Janitor's Closet JF: Joint Filler K: Kickplate KIT: Kitchen KS: Kitchen Sink KW: Kilowatt L: Left, Length LAD: Ladder LAM: Laminate, Laminated LB: Pound (weight), Lag Bolt LBL: Label LBR: Lumber LCD: Liquid Crystal Diode LCL: Linen Closet LCM: Lead Coated Metal LD: Leader Drain LH: Left Hand LIB: Library LINO: Linoleum LIQ: Liquid LKR: Locker LL: Live Load LMS: Limestone LN: Length LNDG: Landing LOC: Locate LOCS: Locations LR: Living Room LS: Loud Speaker LT: Light LTG: Lighting LTL: Lintel LV: Low Voltage LVR: Louver LW: Light Weight LWC: Light Weight Concrete MACH: Machine MAINT: Maintenance MARB: Marble MAS: Masonry MATL: Material MAX: Maximum MB: Mail Box MC: Medicine Cabinet MECH: Mechanical MED: Medium MEMB: Membrane MET: Metal MEZZ: Mezzanine MFD: Manufactured, Metal Floor Deck MFG: Manufacturer, Manufacturing MH: Manhole MIKE: Microphone MIN: Minimum MIR: Mirror MISC: Miscellaneous MLDG: Molding MO: Masonry Opening MOD: Module MONO: Monolithic MOV: Movable MRD: Metal Roof Deck MT: Mount, Mounted MTL: Material, Metal MTR: Motor MULL: Mullion MWK: Millwork N: North NATL: Natural NEC: National Electrical Code NEUT: Neutral NI: Nickel NIC: Not In Contract NO: Number NOM: Nominal NR: Noise Reduction NRC: Noise Reduction Coefficient NS: Near Side NTS: Not To Scale O TO O: Out to Out OA: Outside Air, Overall OC: On Center OD: Outside Diameter OF: Outside Face OFF: Office OH: Overhead OHD: Overhead Door OI: Ornamental Iron OPNG: Opening OPP: Opposite OPP H: Opposite Hand ORN: Ornamental OUT: Outlet OVFL: Overflow OZ: Ounce P: Paint P. LAM: Plastic Laminate P SL: Pipe Sleeve PAR: Parallel PARTN: Partition PB: Panic Bar PBD: Particle Board PC: Precast Concrete PCF: Pounds per cubic foot PD: Pump Discharge, Plaza Drain PE: Professional Engineer PED: Pedestal, Pedestrian PERF: Perforate PERIM: Perimeter PERP: Perpendicular PFN: Prefinished PH: Phase, Phone PKG: Parking PKWY: Parkway PL: Property Line PLAS: Plastic PLAS LAM: Plastic Laminate PLF: Pounds Per Lineal Foot PLMBG: Plumbing PLTF: Platform PLWD: Plywood PNL: Panel PNT: Paint POL: Polish, Polished PORC: Porcelain PORT: Portable POT W: Potable Water PP: Precast Panel PR: Pair PRC: Precast PREFAB: Prefabricated PRES: Pressure PRFMD: Preformed PRI: Primary PRMLD: Premolded PROT: Protection, Protective PRSTR: Prestressed PRTN: Partition PS: Plumbing Stack PSC: Prestressed Concrete PSF: Pounds per square foot PSI: Pounds per square inch PT: Point PTC: Post-Tensioned Concrete PTD: Paper Towel Dispenser PTD/R: Combination Paper Towel Dispenser/Receptacle PV: Paving PVG: Paving PVMT: Pavement PVT: Private PWR: Power QUAL: Quality QT: Quarry Tile, Quart QTR: Quarter QTY: Quantity R: Radius R & S: Rod and Sealant RA: Return Air, Registered Architect RAD: Radiator RB: Rubber RBT: Rabbet RCP: Reflected Ceiling Plan RD: Roof Drain, Round REBAR: Reinforcing Bar RECP: Receptacle REF: Refer, Reference, Refrigerator REFL: Reflected, Reflector REG: Regular REINF: Reinforcement, or Reinforce REQ: Require, Required RESIL: Resilient RET: Return, Retaining REV: Reverse, Revise, Revision RF: Roof RFG: Roofing RGTR: Register RGH: Rough RH: Right Hand RHR: Right Hand Reverse RM: Room RMV: Remove, Removable RO: Rough Opening ROW: Right of Way RPM: Revolutions Per Minute RT: Rubber Tile, Right RTR/RR Rubber Tread/Rubber Riser RVS: Reverse Side RVT: Rivet RWC: Rain Water Conductor RWL: Rain Water Leader S: South, Sealant, Supply S&S: Stained & Sealed S&V: Stain & Varnish SACT: Suspended Acoustical Tile SALV: Salvage SAN: Sanitary SC: Solid Core SCD: Seat Cover Dispenser SCH: Schedule SCR: Screen SCUP: Scupper SCWD: Solid Core Wood SD: Soap Dispenser SE: Structural Engineer SEC: Second, Secondary, Security System SECT: Section SEL: Select SERV: Service SF: Square Foot SFGL: Safety Glass SGS: Silicone Glazing Sealant SH: Shelf SHT: Sheet SHTHG: Sheathing SHWR: Shower SIG: Signal SIM: Similar SJS: Silicone Joint Sealant SK: Sink SKL: Skylight SLV: Sleeve SND: Sanitary Napkin Dispenser SP: Standpipe, Soundproof SPC: Spacer SPECS: Specifications SPK: Speaker SPL: Special SPLR: Sprinkler SPM: Sprinkler Main SPP: Skim Coat Plaster Painted SQ: Square SS: Stainless Steel, Soil Stack SSGS: Silicone Structural Glazing Sealant SSK: Service Sink ST: Storm Water STA: Station STC: Sound Transmission Class STD: Standard STG: Storage, Seating STK: Stack STL: Steel STOR: Storage STRUC: Structural STWY: Stairway SUPP: Supplementary, Supplement SUPT: Superintendent SUR: Surface SUSP: Suspended, Suspend SV: Safety Relief Valve SW: Switch SWBD: Switchboard SWGR: Switchgear SY: Square Yard SYM: Symmetrical SYN: Synthetic SYS: System T: Tread T/: Top of T&B: Top and Bottom T&G: Tongue & Groove TAN: Tangent TB: Towel Bar TC: Top of Curb, Terracotta TD: Trench Drain TEL: Telephone TEMP: Temporary, Tempered, Temperature TEN: Tenant TERM: Terminal TH: Thermostat THK: Thick, Thickness THR: Threshold THRM: Thermal THRU: Through TLT: Toilet TOL: Tolerance TP: Top of Pavement TPD: Toilet paper Dispenser TPH: Toilet Paper Holder TPTN: Toilet Partition TRANS: Transformer, Translucent TRAV: Travertine TRD: Tread TSL: Top of Slab TST: Top of Steel TT: Traffic Topping TTC: Telephone Terminal Closet TW: Top of Wall TYP: Typical TZ: Terrazzo UH: Unit Heater UL: Underwriters' Laboratories UNEXC: Unexcavated UNFIN: Unfinished UNO: Unless Noted Otherwise UR: Urinal USG: United States Gypsum Company UT: Utility V: Volt VAR: Varies VB: Vapor Barrier VCT: Vinyl Composition Tile VENT: Ventilate, Ventilator VERT: Vertical VEST: Vestibule VF: Vinyl Fabric VIF: Verify In the Field VIN: Vinyl VNR: Veneer VOL: Volume VP: Vapor Proof, Vent Pipe VR: Vapor Retarder VS: Vent Stack VT: Vinyl Tile VTR: Vent Through Roof VWC: Vinyl Wall Covering W: West, Width, Wide, Watt, Waste, Water, Water W/: With W/O: Without WAINS: Wainscot WB: Wood Base WC: Watercloset WD: Wood WDP: Wood, Painted WDSS: Wood, Stained & Sealed WF: Wide Flange (structural steel) WGL: Wire-Glass WH: Water Heater, Wall Hung, Wall Hydrant WI: Wrought Iron WIN: Window WM: Wire Mesh, Water Meter WP: Waterproof, Weatherproof WPR: Waterproofing WPT: Working Point WR: Water Resistant, Water Repellant WS: Weatherstripping, Water Stop WT: Weight, Water Table, Watertight WVNR: Wood Veneer WWF: Welded Wire Fabric X HVY: Extra Heavy X STR: Extra Strong YD: Yard YR: Year ABBREVIATION LEGEND GENERAL NOTES 1. GROUND FLOOR ELEVATION 0’-0” = 834.5’. 2. ALL DIMENSIONS ARE FROM FACE TO FACE OF STUDS UNLESS NOTED OTHERWISE. 3. ALL INTERIOR BUILDING FINISHES TO CONFORM TO REQUIREMENTS OF THE 2006 INTERNATIONAL BUILDING CODE W/ INDIANA AMENDMENTS. 4. ANY AND ALL PENETRATIONS SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS. IF ANY PENETRATION IS THROUGH A FIRE RATED ASSEMBLY, THE PENETRATION MUST MEET A TESTED ASSEMBLY ACCEPTABLE TO CODE. SUBMIT DOCUMENTATION, PER SPECIFICATIONS. 5. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS PRIOR TO PROCEEDING WITH WORK. 6. THE CONTRACTOR TO VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS. 7. THE POSTING OF AN OFFICIAL DESIGN RELEASE AND MAINTENANCE OF ONE SET OF PLANS AND SPECIFICATIONS ON THE JOB SITE IS REQUIRED. 8. THE G.C. OR OWNER SHALL FILE ALL DRAWINGS FOR PERMIT APPLICATION OR OTHER MATERIALS REQUIRED TO SECURE ANY AND ALL NECESSARY BUILDING PERMITS AS MIGHT BE REQUIRED BY ANY LOCAL ORDINANCES TO PERFORM THIS WORK. 9. THE DRAWINGS ARE NOT TO BE SCALED. INFORMATION CONCERNING EXISTING PARTITIONS, ETC.VERIFICATION MUST BE DONE IN THE FIELD. 10. THE USE OF THE WORDS "PROVIDE" OR "PROVIDED" IN CONNECTION WITH ANY ITEM SPECIFIED IS INTENDED TO MEAN, UNLESS OTHERWISE NOTED, THAT SUCH SHALL BE FURNISHED, INSTALLED AND CONNECTED WHERE SO REQUIRED. 11. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. 12. UPON COMPLETION OF PROJECT, PROVIDE OWNER WITH ALL INSTRUCTION MANUALS, WARRANTIES OR OTHER DOCUMENTS REQUIRED FOR OPERATION OR MAINTENANCE OF ANY ITEM IN THE CONTRACTORS WORK. 13. THESE CONSTRUCTION NOTES AND/OR DRAWINGS ARE SUPPLIED TO ILLUSTRATE THE DESIGN AND GENERAL TYPE OF CONSTRUCTION DESIRED AND ARE INTENDED TO IMPLY THE FINEST QUALITY OF CONSTRUCTION MATERIAL AND WORKMANSHIP THROUGHOUT. 14. THE OWNER SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON THE SITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES. 15. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES. ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. 16. SECTIONS INDICATED AS TYPICAL MIGHT NOT BE INDICATED ON PLAN SHEETS. IT IS THE CONTRACTORS RESPONSIBILITY TO USE TYPICAL SECTIONS WHERE REQUIRED. 17. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY BRACING AND/OR SHORING UNTIL THE PERMANENT BRACING IS IN PLACE. 18. ALL CONTRACTORS ARE REQUIRED TO COORDINATE THEIR WORK WITH ALL DISCIPLINES TO AVOID CONFLICTS, SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING SIZE AND QUANTITY OF OPENINGS, SLAB REQUIREMENTS AND LINTELS. 19. THESE DRAWINGS ARE NOT TO BE SEPARATED. 20. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS AND SPECIFICATIONS PRIOR TO BEGINNING WORK AND/OR PLACING ORDERS. 21. CONTRACTOR SHALL PROVIDE WOOD BLOCKING IN WALLS FOR MOUNTING CABINETS. 22. ALL NEW DOORS TO BE INSTALLED WITH HINGE SIDE 4" MINIMUM AWAY FROM WALL. 23. ALL GYPSUM BOARD AT THE INTERIOR SIDE OF “COMMERCIAL” ROOMS ARE NOT INCLUDED IN THIS BID SET UNLESS NOTED OTHERWISE. 10/6/2017 10/6/2017 04/16/18 Nick Mishler