Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A106 Enlarged Apt. Plans
Hamilton Commercial and Residential Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date LGA, EJD, DJS Laurence Armstrong Carmel, Indiana 46032 #### SCALE: NTS PLAN NORTH KEY PLAN PARK EAST PEDCOR DESIGN GROUP LLC A106 Enlarged Apt. Plans THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2017 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA. Construction Documents By: Friday, October 6, 2017, BIM Server: BIM20 - BIM Server 20/BLDG E/Building E Retail F DW FRN FRN WH F DW 5 A107 5'-9 3/4" 9" A1 A305 B1 A305 7 13 7 13 W6B W4B W4B W4B W4B W4B W4B W4B W4Ji W4B W4B W4B W4B W4EI W4EI W4B W4EI ED3 AD1 AD2 AD3 AD4 W4A W4Ji W4Ji M6 i M6 i DINING ROOM LIVING ROOM 1/2 BATH HALL PANTRY MECH. CLOSET KITCHEN ENTRY STAIRS COATS UP FRN FRN EDGE OF SIDEWALK WH 1 A107 24'-0" 7 1/2" 22'-7 1/2" 2'-4 1/2" 3'-6 1/8" 4'-6 1/4" 3'-8 3/4" 4'-7/8" 6'-7" 2'-10" 2'-6 5/8" 4'-5/8" 2'-6 3/4" 1'-1" 4'-3/8" 6'-1 3/4" 2'-1 1/4" 11'-1/4" 4'-1 5/8" 4'-1 7/8" 11'-6 3/8" 7'-8 1/4" 4'-3/8" 9" 1'-11 3/8" 2'-10 1/4" 1'-7 7/8" 2'-10 1/4" 2'-8 3/4" 11 1/8" 3'-5 3/4" 1'-3 7/8" 2'-10 1/4" 2'-7 1/4" 2 1 10 5 W4Ji W4EI 6 9 12 13 A107 13 A107 DOOR SCHEDULE NOTES: 1. ALL NEW INTERIOR DOORS TO BE: TRUSTYLE MDF DOORS, MODEL#TS2020, 2 PANEL OPTION OR EQUAL. 2. ALL DOORS TO BE PAINTED P3. 3. ALL WOOD DOOR FRAMES TO BE PREPPED AND PAINTED SEMI-GLOSS P3. 4. DOOR VENDOR TO FABRICATE DOOR WITH A 1” UNDERCUT AT BEDROOMS, BATHROOMS AND WALK IN CLOSETS FOR RETURN AIR. 5. SEE SPECIFICATION SECTION NO. 870-13 FOR HARDWARE SCHEDULE. 6. ALL DOORS TO HAVE WALL-MOUNTED DOOR STOPS MOUNTED AT BASEBOARD, UNLESS OTHERWISE NOTESD. USE HINGE PIN DOOR STOP WHERE WALL STOP CANNOT BE MOUNTED ON BASEBOARD. 7. ALL FIRST FLOOR WING DOORS REQUIRING THRESHOLDS SHALL BE MAX ½” HIGH. 8. PROVIDE ENERGY STAR INSULATED DOOR. SEE “HERS” DESIGN REQUIREMENTS ON CS SHEET. HARDWARE DOOR FRAME HEAD JAMB SILL SET ED 1, 3, 5, 7, 9 ENTRY REF. SHEET A602 VARIES VARIES MTL/ GL MTL 1/A602 2/A602 1/A602 LOCK SET SEE NOTE 'A' ED 2, 4, 6, 8, 10 BALCONY REF. SHEET A602 VARIES VARIES MTL/ GL MTL 1/A602 2/A602 1/A602 LOCK SET SEE NOTE 'A' AD1 CLOSET B SHEET A602 2 PANEL (2) 1'-8"X6'-8" WD WD 8/A602 9/A602 NONE DUMMY/ BALL CATCH SEE NOTE 'A' AD2 POWDER ROOM A SHEET A602 2 PANEL 2'-10"X6'-8" WD WD 8/A602 9/A602 NONE PASSAGE SEE NOTE 'B' AD3 PANTRY B SHEET A602 2 PANEL (2) 2''-0"X6'-8" WD WD 8/A602 9/A602 NONE DUMMY/ BALL CATCH SEE NOTE 'A' AD4 MECHANICAL A SHEET A602 2 PANEL 2'-10"X6'-8" WD WD 8/A602 9/A602 NONE PASSAGE SEE NOTE 'B' AD5 BEDROOM A SHEET A602 2 PANEL 2'-6"X6'-8" WD WD 8/A602 9/A602 NONE PRIVACY SEE NOTE 'B' AD6 BATHROOM A SHEET A602 2 PANEL 2'-6"X6'-8" WD WD 8/A602 9/A602 NONE PRIVACY SEE NOTE 'A' AD7 CLOSET A SHEET A602 2 PANEL 2'-4"X6'-8" WD WD 8/A602 9/A602 NONE PASSAGE SEE NOTE 'A' AD8 BEDROOM A SHEET A602 2 PANEL 2'-6"X6'-8" WD WD 8/A602 9/A602 NONE PRIVACY SEE NOTE 'B' AD9 BATHROOM A SHEET A602 2 PANEL 2'-6"X6'-8" WD WD 8/A602 9/A602 NONE PRIVACY SEE NOTE 'B' AD10 CLOSET A SHEET A602 2 PANEL 2'-4"X6'-8" WD WD 8/A602 9/A602 NONE PASSAGE SEE NOTE 'A' AD11 LINNEN A SHEET A602 2 PANEL 2'-4"X6'-8" WD WD 8/A602 9/A602 NONE PASSAGE SEE NOTE 'A' AD12 LAUNDRY A SHEET A602 2 PANEL 3'-0"X6'-8" WD WD 8/A602 9/A602 NONE PASSAGE SEE NOTE 'B' NOTE: A. PROVIDE HINGE PIN STOP, IVES 73 AS REQUIRED. B. PROVIDE BASEBOARD STOPS, IVES 60 OR HINGE PIN STOP AS REQUIRED. DETAIL DOOR SCHEDULE MARK LOCATION ELEVATION STYLE SIZE MATERIAL REMARKS CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH. ALL NEW DOOR FRAMES TO BE FINISHED TO MATCH EXISTING FRAMES. CAULK INTERIOR AND EXTERIOR PERIMETERS OF ALL HOLLOW METAL AND ALUMINUM DOOR FRAMES. 1. 2. 3. 5. 8. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPET IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. 9. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. 10. 11. GROUT TO BE 100% EPOXY. COLOR TO BE SELECTED BY DESIGNER. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK TO DESIGNER FOR REVIEW AND APPROVAL BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. ALL DRYWALL BULKHEADS ARE TO BE PAINTED , UNLESS NOTED OTHERWISE ON REFLECTED CEILING PLANS. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. PAINT MFG: SHERWIN WILLIAMS COLOR: REQUISITE GRAY SW7023 FINISH: EGGSHELL LOCATION: WALLS P1 PAINT HARDSURFACE TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH. ALL NEW WOOD DOOR FRAMES TO BE STAINED ST1 UNLESS NOTED OTHERWISE. 4. 6. 12. GENERAL FINISH NOTES 13. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED TO MATCH THE ADJACENT WALL FINISH. 7. ALL PAINT COLOR SELECTIONS AND LOCATIONS ARE TO BE DETERMINED IN THE FIELD WITH THE ARCHITECT. LAMINATE FLOORING - 5" PLANK MFG: SHAW STYLE: LEFT BANK SL938 COLOR: EIFFEL MAPLE 00510 LOCATION: GENERAL CONTACT: SUSAN MEDINA 317.710.6555 B1 BASE FLOORCOVERING WALL TILE GLAZED CERAMIC TILE 3"X6" MFG: AMERICAN OLEAN PATTERN: PROFILES COLOR: 0025 ICE WHITE, GLOSS GROUT: SOAP DISH: BA725 ICE WHITE 25 CONTACT: TRACEY KESSENS, 317.284.0732 LOCATION: BATHTUB NOTE: INSTALL RUNNING BOND FINISH LEGEND CABINETS MFG: MERILLAT CLASSIC SPECIES: MAPLE COLOR: COTTON STYLE: PORTRAIT SIZE: SEE ELEVATIONS HARDWARE: BERENSON, 9402-2BPN-P LOCATION: KITCHEN AND BATHROOM CB1 SS1 SOLID SURFACE MFG: STARON COLOR: PEARL SP011 LOCATION: WINDOW SILLS SOLID SURFACES MISC. CARPET W/PAD MFG: SHAW PATTERN: DREAM OF MINE COLOR: 501 SLATE LOCATION: BEDROOMS,CLOSETS CONTACT: POCELAIN TILE - 12"X12" MFG: MS INTERNATIONAL PATTERN: BETON CONCRETE COLOR: GRAY GROUT: TEC, CHARCOAL GRAY 929 SOURCE: KEVIN FORREST 513.383.8082 LOCATION: BATHROOMS, LAUNDRY PAINTED WOOD BASE SEE DETAIL XX/XXX COLOR: P3 LOCATION: GENERAL GRANITE SLAB THICKNESS: 3CM COLOR: GIALLO ORNAMENTAL EDGE: SQUARE LOCATION: KITCHEN COUNTER AND BATHROOM COUNTER NS1 NATURAL STONE PAINT MFG: SHERWIN WILLIAMS COLOR: CEILING BRIGHT WHITE SW7007 FINISH: FLAT LOCATION: CEILINGS,BULKHEADS P2 PAINT MFG: SHERWIN WILLIAMS COLOR: REQUISITE GRAY SW7023 FINISH: SEMI-GLOSS LOCATION: DOORS & TRIM P3 WB1 WINDOW BLINDS MFG: LOTUS OR EQUAL COLOR: WHITE SIZE: 2" FAUX WOOD LOCATION: WINDOWS VERIFY UNDERCUT REQUIREMENTS FOR DOORS WHERE CARPET OR OTHER FLOORING IS TO BE INSTALLED. ALTERNATES 1. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. CONTRACTOR TO VERIFY LEAD TIMES AS SOON AS CONTRACT IS AWARDED AND NOTIFY ARCHITECT IF SPECIFIED FINISHES WILL NOT BE AVAILABLE. DESIGN FEES MAY ACCRUE FOR TIME SPENT TO RESELECT ANY MATERIALS WHICH BECOME UNAVAILABLE DUE TO DELAYS IN ORDERING. WD1 W1 C1 PCT1 GENERAL NOTES 1. GROUND FLOOR ELEVATION 0’-0” = 834.5’. 2. ALL DIMENSIONS ARE FROM FACE TO FACE OF STUDS UNLESS NOTED OTHERWISE. 3. ALL INTERIOR BUILDING FINISHES TO CONFORM TO REQUIREMENTS OF THE 2006 INTERNATIONAL BUILDING CODE W/ INDIANA AMENDMENTS. 4. ANY AND ALL PENETRATIONS SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS. IF ANY PENETRATION IS THROUGH A FIRE RATED ASSEMBLY, THE PENETRATION MUST MEET A TESTED ASSEMBLY ACCEPTABLE TO CODE. SUBMIT DOCUMENTATION, PER SPECIFICATIONS. 5. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS PRIOR TO PROCEEDING WITH WORK. 6. THE CONTRACTOR TO VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS. 7. THE POSTING OF AN OFFICIAL DESIGN RELEASE AND MAINTENANCE OF ONE SET OF PLANS AND SPECIFICATIONS ON THE JOB SITE IS REQUIRED. 8. THE G.C. OR OWNER SHALL FILE ALL DRAWINGS FOR PERMIT APPLICATION OR OTHER MATERIALS REQUIRED TO SECURE ANY AND ALL NECESSARY BUILDING PERMITS AS MIGHT BE REQUIRED BY ANY LOCAL ORDINANCES TO PERFORM THIS WORK. 9. THE DRAWINGS ARE NOT TO BE SCALED. INFORMATION CONCERNING EXISTING PARTITIONS, ETC.VERIFICATION MUST BE DONE IN THE FIELD. 10. THE USE OF THE WORDS "PROVIDE" OR "PROVIDED" IN CONNECTION WITH ANY ITEM SPECIFIED IS INTENDED TO MEAN, UNLESS OTHERWISE NOTED, THAT SUCH SHALL BE FURNISHED, INSTALLED AND CONNECTED WHERE SO REQUIRED. 11. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. 12. UPON COMPLETION OF PROJECT, PROVIDE OWNER WITH ALL INSTRUCTION MANUALS, WARRANTIES OR OTHER DOCUMENTS REQUIRED FOR OPERATION OR MAINTENANCE OF ANY ITEM IN THE CONTRACTORS WORK. 13. THESE CONSTRUCTION NOTES AND/OR DRAWINGS ARE SUPPLIED TO ILLUSTRATE THE DESIGN AND GENERAL TYPE OF CONSTRUCTION DESIRED AND ARE INTENDED TO IMPLY THE FINEST QUALITY OF CONSTRUCTION MATERIAL AND WORKMANSHIP THROUGHOUT. 14. THE OWNER SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON THE SITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES. 15. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES. ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. 16. SECTIONS INDICATED AS TYPICAL MIGHT NOT BE INDICATED ON PLAN SHEETS. IT IS THE CONTRACTORS RESPONSIBILITY TO USE TYPICAL SECTIONS WHERE REQUIRED. 17. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY BRACING AND/OR SHORING UNTIL THE PERMANENT BRACING IS IN PLACE. APARTMENT PLAN NOTES 1. NEW PORTABLE 2A:10B:C FIRE EXTINGUISHER TO BE PROVIDED IN EACH UNIT. PLACE FIRE EXTINGUISHER IN CABINET UNDER SINK. 2. (2) 12" DEEP 3/4" PARTICAL BOARD SHELF ON WALL CLEATS WITH SINGLE ROD. SEE DETAIL A4/A502. 3. (2) 12" DEEP 3/4" PARTICAL BOARD SHELVES ON WALL CLEATS WITH SINGLE ROD AT (3) OF THE SHELVES. INCLUDE ALSO (1) BOX SHELF UNIT WITH (5) SHELVES. SEE DETAIL A3/A502. 4. (1) 16" DEEP 3/4" PARTICAL BOARD SHELF ON WALL CLEATS OVER FUTURE WASHER AND DRYER. SEE DETAIL B2/A502 & B3/502. 5. 5) 16" DEEP 3/4" PARTICAL BOARD SHELVES ON WALL CLEATS. PROVIDE ADDITIONAL BLOCKING AS REQUIRED. SEE DETAIL B1/A520. 6. GRANITE PENINSULA COUNTER. SAME HEIGHT AS KITCHEN COUNTER TOP 7. SOLID SURFACE WINDOW SILL. REF SHEET 17/A106. 8. 1 HR. WALL AT TUB, SEE DETAIL C3/A502. 9. LOUVER VENT CLOSET WALL. FRAMING AS REQ'D TO BOX IN LOUVER 6” ABOVE TOP OF DOOR. 10. REFRIGERATOR WITH ICE MAKER, ADD WATER LINE. 11. REFERENCE ELECTRICAL DRAWINGS FOR TECHNOLOGY BOARD AT THIS LOCATION. 12. REFERENCE ELECTRICAL DRAWINGS FOR ELECTRICAL PANEL AT THIS LOCATION. 13. PROVIDE WINDOW BLINDS AT ALL WINDOWS AND DOORS IN APARTMENT UNITS. SEE FINISH LEGEND FOR SPECIFICATION. 14. INSTALL LINT TRAP ACCESS DOOR 48” TO BOTTOM. SEE DETAIL B3/A502. VERIFY EXACT LOCATION WITH MECH. PLANS. 15. SLOPED CEILING UNDER STAIRS. 16. CEILING AT 8’. 18. ALL CONTRACTORS ARE REQUIRED TO COORDINATE THEIR WORK WITH ALL DISCIPLINES TO AVOID CONFLICTS, SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING SIZE AND QUANTITY OF OPENINGS, SLAB REQUIREMENTS AND LINTELS. 19. THESE DRAWINGS ARE NOT TO BE SEPARATED. 20. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS AND SPECIFICATIONS PRIOR TO BEGINNING WORK AND/OR PLACING ORDERS. 21. CONTRACTOR SHALL PROVIDE WOOD BLOCKING IN WALLS FOR MOUNTING CABINETS. 22. ALL NEW DOORS TO BE INSTALLED WITH HINGE SIDE 4" MINIMUM AWAY FROM WALL. 23. ALL GYPSUM BOARD AT THE INTERIOR SIDE OF “COMMERCIAL” ROOMS ARE NOT INCLUDED IN THIS BID SET UNLESS NOTED OTHERWISE. Light Fixture Schedule Symbol Room Name Manufacturer Fixture Name Catalog # Light Bulb Finish Remarks L-1 GENERAL ASL Decorative Flush Mount TTL 14"x5 1/2" LED Satin Nickel L-3 BATH ROOMS Justice Design Group Rondo 3 Light Bath Bar FSN-8513 LED Satin Nickel L-4 BATH Broan 689 Wall Mounted Exhaust Fan L-5 KITCHEN/BAR ASL Mini Pendant RFHS-10-DV-X-3000K LED Brushed Nickel L-6 L-7 GENERAL Halo 4" Surface LED SLD405930WHJB LED WHITE Junction box fire rated up to 2 hours. L-8 L-9 EXTERIOR L-2 GENERAL DINING Dolan Designs Radiance 25 in. Chandelier 1290-09 LED Satin Nickel ASL Decorative Flush Mount TTL 11"x4 1/2" LED Satin Nickel BEDROOMS Latitude Run Contemporary 44" Cedarton Hugger 5 blade Ceiling Fan LRUN7514 LED BRUSHED Nickel T SD 220 J THERMOSTAT CABLE SERVICE PHONE SERVICE REFLECTED CEILING LEGEND: RECESSED DOWNLIGHT FIXTURE WET LOCATION COMBO LIGHT / EXHAUST FAN FIXTURE MINI PENDANT FIXTURE MULTI-LAMP VANITY SCONCE ELECTRIC PANEL RESIDENTIAL EXTERIOR LIGHT FIXTURE 1/2 SWITCHED OUTLET GFI PROTECTED OUTLET FIRE ALARM STROBE AND SPEAKER FIRE ALARM SMOKE DETECTOR WEATHER PROOF OUTLET 220V. OUTLET JUCTION BOX SURFACE MOUNTED FIXTURE CEILING FAN/LIGHT L-1 L-3 L-4 L-8 L-5 L-6 L-9 OUTLET MAXIM BUNGALOW 11" 55652CDWSBZ LED BRONZE OUTDOOR WALL MOUNT L-2 SURFACE MOUNTED FIXTURE L-7 CHANDELIER GENERAL CEILING NOTES: 1. REFERENCE MEP DRAWINGS. 2. CEILING HEIGHT DESIGNATED BY BENCHMARK ABOVE FINISHED FLOOR (AFF). 3. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 4. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. 5. TRADES TO COORDINATE THE HEIGHT OF FIRE SUPPRESSION LINES, ROOF DRAIN LEADERS, ROOF STACK VENTS AND CONDENSATE LINES TO ALLOW FOR CEILING HEIGHTS AS INDICATED ON THE REFLECTED CEILING PLAN. 6. SEE RCP PLANS AND SCHEDULE FOR CEILING HEIGHTS. 7. GYPSUM BOARD FINISHING: A. COMPLY WITH ASTM C 840 STANDARD SPECIFICATION AND FINISHING OF GYPSUM BOARD; GA 214 RECOMMENDED LEVELS OF GYPSUM BOARD FINISH; AND GA 216-2000 APPLICATION AND FINISHING OF GYPSUM BOARD. B. PROVIDE GYPSUM BAORD MINIMUM FINISH LEVELS MEETING THE CRITERIA ESTABLISHED IN GA 214 AS FOLLOWS: 1. LEVEL 1 – GYPSUM WALL BOARD PERMANENTLY CONCEALED FROM VIEW. 2. LEVEL 2 – GYPSUM BOARD BEHIND AND APPLIED WALL COVERING AND WALLS AND CEILINGS IN MECHANICAL AND EQUIPMENT ROOMS. 3. LEVEL 4 – GYPSUM WALL BOARD ON INTERIOR WALLS FOR ALL TENANT AREAS. 4. LEVEL 5 – GYPSUM WALL BOARD ON FINISHED CEILINGS AND ALL COMMON AREA WALLS. GENERAL ELECTRICAL NOTES: 1. REFERENCE MEP DRAWINGS 2. ALL ELECTRICAL WORK TO BE PERFORMED BY A LICENSED, ELECTRICAL CONTRACTOR. 3. ALL WORK TO MEET THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE AND RULES AND REGULATIONS OF THE STATE OF INDIANA. 4. PROVIDE ALL MATERIAL AND LABOR TO COMPLETE THE WORK AS INDICATED AND AS REQUIRED. 5. ALL MATERIAL TO BE NEW AND U.L. RATED AND SEALS ARE TO BE VISIBLE. 6. TWO COPIES OF OPERATION AND MAINTENANCE MANUALS FOR ALL EQUIP. HEREIN INSTALLED SHALL BE GIVEN TO THE OWNER PRIOR TO ACCEPTANCE OF THE SPACE FOR OCCUPANCY. 7. CONTRACTOR SHALL VERIFY THE SERVICE VOLTAGE WITH THE UTILITY COMPANY. 8. ALL DISCONNECT SWITCHES SHALL BE RATED FOR GENERAL DUTY. 9. E.C. TO PROVIDE FINAL CONNECTIONS TO ALL NEW EQUIPMENT AND APPLIANCES. 10. ALL RECEPTACLES TO BE 15" A.F.F. TO BOTTOM OF ELEC. BOX EXCEPT AS NOTED OR INDICATED OTHERWISE. 11. ALL SWITCHES & THERMOSTATS TO BE 48" A.F.F. TO TOP EXCEPT AS NOTED OR INDICATED OTHERWISE. 12. ALL SWITCHES AND OUTLETS LOCATED ABOVE KITCHEN COUNTER AND BELOW BREAKFAST BAR ARE TO BE MOUNTED SIDEWAYS. 13. SMOKE DETECTOR WITHIN A SINGLE UNIT ARE TO BE LINKED SO THAT WHEN ONE IS ACTIVATED, THEY ALL ARE ACTIVATED. 14 . ALL CEILING MOUNTED LIGHTS IN CLOSETS SHALL BE MOUNTED A MINIMUM OF 12" FROM FACE OF SHELF. COMPLY WITH ELEC. CODE REQUIREMENT SECT. 410.8 15. ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION SHALL BE PROVIDED FOR ALL BRANCH CIRCUITS SUPPLYING OUTLETS IN BEDROOMS. 16. RANGE RECEPTACLE HEIGHT TO BE COORDINATED WITH MANUFACTURER SUPPLYING APPLIANCE. 17. PLUG IN DISHWASHER AND DISPOSAL UNDER SINK OUTLET. HALF HOT FOR DISHWASHER AND HALF SWITCHED FOR DISPOSAL. 18. PROVIDE UL LISTED COMBINATION OUTLET/RECEPTACLE BOX AND FIXTURE BLOCK FOR SIDING USE AT ALL SIDING LOCATIONS - MATCH SIDING COLOR. 19. WATER HEATER DISCONNECT: DISCONNECT FOR WATER HEATER SHALL BE BY CIRCUIT BREAKER CAPABLE OF BEING "LOCKED OUT" OR BY PROVIDING DISCONNECT SWITCH ADJACENT TO WATER HEATER. 20. EXPOSED MATERIALS IN MECHANICAL ROOMS USED AS PLENUMS SHALL BE "PLENUM RATED" AS ACCEPTABLE TO CODE AUTHORITIES. CEILING-ELECTRICAL PLAN NOTES: 1. DUPLEX RECEPTACLE WITH (2) USB CHARGER PORTS TO BE: HUBBELL 15A 125V 2P3W OR EQUAL. 2. PROVIDE 18”x18” ACCESS PANEL FOR DRYER BOOSTER FAN AT THIS LOCATION. ACCESS PANEL TO BE 1 HOUR RATED ASSEMBLY WITH SECURITY LATCH. FRAME AND PANEL ARE TO BE CONCEALED FLANGE TYPE REQUIRING DRYWALL FINISHING AND CEILING FINISH. 3. PROVIDE DUAL SWITCHES AND BRACING FOR FUTURE CEILING FAN. 4. USE CEILING FAN JUNCTION BOXES AT BEDROOM LIGHT FIXTURES AND A 2ND CIRCUIT FOR FUTURE FAN. USE A BLANK SWITCH LOCATION AT THE WALL. 5. INSTALL VANITY LIGHT CENTERED ON VANITY. MOUNT AT 7’-4” AFF TO BOTTOM OF FIXTURE. 6. CEILING AT 8’, FINISHED 7. SLOPED CEILING UNDER STAIRS. 8. CEILING AT 7’-6 ½”, FINISHED. NOTE: ALL OPENINGS OR PENETRATIONS (I.E. PLUMBING VENTS, ETC.) THROUGH THE FIRE RATED WALL, CEILINGS AND/OR FLOOR SYSTEMS REQUIRE PROPER PROTECTIVE FIRE STOPPING. FIRE COLLARS AND FIRE CAULKING SHALL BE PROPERLY INSTALLED, LOCATED AT THE FIRST AND SECOND FLOOR CEILING AT THE HEIGHT OF TOP PLATES, SECOND AND THIRD FLOOR AT FINISHED FLOOR LINE, THIRD FLOOR CEILING AT HEIGHT OF TOP PLATES AND ANY PENETRATIONS OF RATED WALL ASSEMBLES. NOTE: THESE DRAWINGS ARE INTENDED TO DOCUMENT THE GENERAL REQUIREMENTS FOR ELECTRICAL SYSTEMS. THEY MAY NOT BE COMPLETE IN EVERY RESPECT. THE ELECTRICAL CONTRACTOR IS REQUIRED TO PROVIDE ALL NECESSARY LABOR, EQUIPMENT, ACCESSORIES, ETC., FOR A COMPLETE & OPERATING INSTALLATION, WHETHER OR NOT INDICATED ON THESE DOCUMENTS. 9 10 DR W DR 8 A107 A1 A305 B1 A305 7 1/2" 22'-7 1/2" 1'-4 1/2" 11'-2 7/8" 12'-1/8" 7'-4 3/4" 3'-10 1/8" 7'-8 1/4" 4'-3 7/8" 4'-1 1/4" 4'-6 1/8" 5'-4 5/8" 1'-3 3/4" 10'-8 3/4" 28'-4 3/4" 2'-10 1/4" 2'-7 1/2" 1'-3 3/4" 1'-11 1/4" 2'-10 1/4" 1'-8" 2'-10 1/4" 1'-11 1/8" 1'-8 3/4" 3'-5 7/8" 5 5/8" 26'-1/2" 2'-4 1/4" 4'-1 1/4" 3'-5 1/2" 4'-6 1/8" 5'-4 3/4" 11'-2 5/8" 2'-2" 7 13 7 13 W4G W4G W4B W4B W4G W4G W4G W4Ji W4Ji W4B W4EI W4EI W4EI W4Ji W4B W4G W4B W4B W4B W4B W4B W4B W4G W4G W4G W4G ED4 AD5 AD6 AD7 AD8 AD9 AD10 AD11 AD12 M6 i M6 i HALL LAUNDRY STAIRS DOWN HALL CLOSET 2 CLOSET 1 LINEN CLOSET BATH 2 BATH 1 BEDROOM 1 BEDROOM 2 BALCONY TO CMU TO CMU TO CMU TO CMU 8 A107 26'-4 5/8" 26'-1/2" 13 A107 13 A107 5 3 W4EI W4Ji 14 4 8 2 2 3 2 2 11 9 10 9 10 9 10 DR W DR STAIRS DOWN PLUMBING FIXTURE SCHEDULE REF # DESCRIPTION MFGR OR SUPPLIER MODEL # COLOR REMARKS P1 STAINLESS STEEL DOUBLE BOWL KITCHEN SINK ELKAY ELUHAD3118 STAINLESS STEEL SEE ENLARGED PLAN FOR LAYOUT SIMPLICE PULL-DOWN KITCHEN SINK FAUCET KOHLER K-596 CHROME P2 UNDERMOUNT LAVATORY PROFLO PF1714U WHITE TWO HANDLE WIDE SPREAD FAUCET PROFLO PF1112MCP CHROME P3 TWO PIECE TOILET PROFLO PF1201 W/SEAT WHITE P3A TWO PIECE TOILET PROFLO PF1203 W/SEAT WHITE P5 GARDEN TUB 36" STERLING 71101112/22 WHITE TUB AND SHOWER TRIM PROFLO PF7661 CHROME NOTES: 1. APPLY BLOCKING REQUIREMENTS FOUND ON SHEET A503 TO ALL BATHROOM UNITS. 2. REFERENCE ___ FOR APPLIANCE/PLUMBING FIXTURE SPECIFICATIONS. 3. ALL KITCHEN CABINETS ARE TO COMPLY WITH VHDA'S MINIMUM CABINET REQUIREMENTS. 4. KITCHEN CABINETS ARE TO BE SCREWED TO STUDS OR BLOCKING WITH A MINIMUM OF FOUR REF # DESCRIPTION MFGR OR SUPPLIER MODEL # COLOR A1 SIDE-BY-SIDE REFRIGERATOR GE GSH22JSDSS STAINLESS STEEL A2 FREE-STANDING ELEC./CONV. RANGE GE JB690SFSS STAINLESS STEEL A3 OVER THE RANGE MICROWAVE OVEN GE JNM3151RFSS STAINLESS STEEL A4 BUILT-IN DISHWASHER GE GSD3360DSS STAINLESS STEEL A5 TOP LOADING WASHER GE GTWN4250DWS WHITE A6 ELECTRIC DRYER GE GTDP490EDWS WHITE A7 GARBAGE DISPOSAL GE GFC525V NOTES: REMARKS UNITS APPLIANCE SCHEDULE INCLUDE ICE MAKER WX9X35 POWER CORD 1/2 HP T1 TOWEL BAR 18" MOEN P5118 - CHROME SEE ELEVATION - 7/A106 T2 TOWEL RING MOEN P5860 - CHROME SEE ELEVATION - 7/A106 T3 TOILET TISSUE HOLDER MOEN P5050 - CHROME SEE ELEVATION - 7/A106 T4 CERAMIC TOWEL BAR AMERICAN OLEAN BA730 - XXX SEE ELEVATION - 8/A106 T5 CURVED SHOWER CURTAIN ROD PROFLO PFCR60CP SEE ELEVATIONS - 9/A106 T6 MIRROR - FRAMELESS WITH POLISHED EDGE SEE ELEVATIONS - 7/A106-12/A106 T7 CERAMIC TUB SOAP DISH AMERICAN OLEAN BA725 - ICE WHITE 25 SEE ELEVATIONS - 9/A106 NOTES: TOILET ACCESSORY SCHEDULE MANUFACTURER OR NUMBER ITEM APPRVED EQUAL CATOLOGUE NUMBER MOUNTING HEIGHT SCALE: 1/4" = 1'-0" 1 First Floor Enlarged Apartment Plan A106 0 2' 4' 8' SCALE: 1/4" = 1'-0" 2 Second Floor Enlarged Apartment Plan A106 NORTH 0 2' 4' 8' NORTH NORTH NORTH 10/6/2017 10/6/2017 +44 GFI +44 USB S +44 GFI +44 GFI +44 GFI 5'-0" 2'-6" EQ. 5'-0" EQ. 6'-1" 5'-1" 8'-0"d 8'-0"d 8'-0"d 8'-0"d 8'-0"d 3 FRN FRN TO LIGHTS ABOVE WH BULKHEAD AT +7'-9" L1 L3 L4 L5 L5 L5 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L6 L7 L9 G 220 SD TV 3 J OUTLET FOR MICROWAVE 7 6 6 6 6 6 SCALE: 1/4" = 1'-0" 3 First Floor Enlarged Apartment Plan RCP A106 0 2' 4' 8' WP EQ. EQ. 6'-0" 6'-0" 3'-2 1/4" EQ. EQ. EQ. EQ. 6'-0" 7'-6 1/2 7'-6 1/2 7'-6 1/2 5 5 8 8 8 TO LIGHT BELOW L1 L1 L1 L2 L2 L2 L2 L2 L2 L3 L3 L5 L5 L8 L8 L9 GFI +42" GFI +42" 3 3 220 SD SD SD TV TV 220 2 2 SCALE: 1/4" = 1'-0" 4 Second Floor Enlarged Apartment Plan RCP A106 0 2' 4' 8' 04/16/18 Nick Mishler