Loading...
HomeMy WebLinkAboutA601 Door Schedule & DetailsHamilton Commercial and Residential Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date LGA, EJD, DJS Laurence Armstrong Carmel, Indiana 46032 #### SCALE: NTS PLAN NORTH KEY PLAN PARK EAST PEDCOR DESIGN GROUP LLC A601 Door Schedule & Details THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2017 JAMES R. STUTZMAN, AIA, CARMEL, INDIANA. Construction Documents By: Friday, October 6, 2017, BIM Server: BIM20 - BIM Server 20/BLDG E/Building E Retail 1" BATT INSULATION CFS BOX HEADER DOOR LEAF 6" MTL. STUD 5/8" GYP. BD. SEALANT HOLLOW METAL FRAME SEE PLAN FOR WALL TYPE/ THICKNESS SEE SCHEDULE AND FRAME TYPE ELEVATION SEALANT HOLLOW METAL FRAME BEYOND 8" 1" DOOR LEAF BATT INSULATION 5/8" GYP. BD. SEALANT SEALANT 5/8" GYP. BD. HOLLOW METAL FRAME MTL. STUD DOOR LEAF HOLLOW METAL FRAME BEYOND CONC. SLAB THRESHOLD SET IN ASPHALT XXX MASTIC 5 3/4" ALIGN FRAME W/ CMU, THIS SIDE 3/8" BACKER ROD AND SEALANT EA. SIDE DOOR LEAF 8" CMU LINTEL, REF. STRUCTURAL DRAWINGS GROUTED HOLLOW METAL FRAME 8" CMU, GROUT CORES SOLID SEE SCHEDULE AND FRAME TYPE ELEVATION SEE PLAN FOR WALL TYPE/ THICKNESS HOLLOW METAL FRAME BEYOND 5 3/4" GROUTED HOLLOW METAL FRAME DOOR LEAF ALIGN FRAME W/ CMU, THIS SIDE 3/8" BACKER ROD AND SEALANT EA. SIDE 8" CMU, GROUT CORE SOLID CMU W/ BULL NOSE CORNER MASONRY ANCHOR ALIGN FRAME W/ CMU, THIS SIDE DOOR LEAF GROUTED HOLLOW METAL FRAME BEYOND CONC. FLOOR LINE OF CMU WALL BEYOND THRESHOLD SET IN ASPHALT MASTIC SEALANT 5 1/2" SEE DOOR SCHED. DOOR LEAF 1/4" JOINT W/ BACKER ROD AND SEALANT SEE PLAN FOR WALL TYPE/ THICKNESS SEE SCHEDULE AND FRAME TYPE ELEVATION LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER EXTENDED OVER CMU BACKER ROD AND SEALANT GROUTED HOLLOW METAL FRAME HOLLOW METAL FRAME BEYOND 8" CMU LINTEL, REF. STRUCTURAL DRAWINGS 8" CMU INSULATE CORES WHERE GROUTING NOT REQUIRED EIFS VENEER EIFS DRAINAGE FLASHING AS REQUIRED SEE DOOR SCHED. 5 1/2" DOOR LEAF 8" CMU, GROUT CORE SOLID EIFS AND GRANITE BASE GROUTED HOLLOW METAL FRAME 3/8" JOINT W/ BACKER ROD AND SEALANT 3/8" JOINT W/ BACKER ROD AND SEALANT CMU W/ BULL NOSE CORNER MASONRY ANCHOR LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER EXTENDED OVER CMU DOOR LEAF HOLLOW METAL FRAME BEYOND CONC. SLAB THRESHOLD SET IN ASPHALT REF. INTERIOR MASTIC FIN. SCHED. LINE OF GRANITE BASE BEYOND EXP. JNT. DOOR AND FRAME SCHEDULE DOOR # D101B D101C D102A D102B D102C D102D D102E D103B D107A ROOM # 101 101 102 102 102 102 102 103 107 TYPE DOOR -- B E F F B D A B FRAME 2 2 2 -- -- 2 -- 2 2 DUTY -- EXT. HD EXT. HD EXT. HD EXT. HD EXT. XHD EXT. HD EXT. HD EXT. XHD DOOR SIZE W 3'-6" 3'-6" 3'-0" 12'… 12'… 3'-0" 8'-0" 4'-0" 4'-0" HT 8'-0" 7'-0" 8'-0" 14'… 14'… 7'-0" 8'-… 7'-0" 7'-0" MATL AL HM HM ST ST HM ST HM HM GLZ G2 G3 G3 -- -- G3 -- G3 G3 FRAME DEPTH 0'-4 1/2" 0'-5 3/4" 0'-7 3/4" 0'-3 7/8" 0'-3 7/8" 0'-5 3/4" 0'-3 7/8" 0'-5 3/4" 0'-5 3/4" MATL -- HM HM ST ST HM ST HM HM DETAIL HEAD Undefined E2/A601 E2/A601 C1/A301 C1/A301 E2/A601 8/A104 E2/A601 E2/A601 JAMB Undefined D2/A601 D2/A601 3/A104 3/A104 D2/A601 7/A104 D2/A601 D2/A601 SILL Undefined C2/A601 C2/A601 -- -- C2/A601 -- C2/A601 C2/A601 FIRE RATING -- 45 45 -- -- -- 45 45 45 HARDWARE SET NO 12 --- --- 12 --- 12 12 KEYSIDE RM NO --- --- --- NOTES Aluminum Storefront, N.I.C. Insulated Door Leaf Insulated Door Leaf Sectional overhead door. Overhead Door Co. Model 418 basis of design. Sectional overhead door. Overhead Door Co. Model 418 basis of design. Insulated Door Leaf Steel Rolling Door Insulated Door Leaf Insulated Door Leaf TYPE IN SCHEDULE: INDICATES DOOR TYPE (SEE DOOR AND FRAME ELEVATIONS) INDICATES FRAME TYPE (SEE DOOR AND FRAME ELEVATIONS) B/1 INDICATES 2 DOOR LEAVES OF DOOR TYPE (SEE DOOR AND FRAME ELEVATIONS) INDICATES FRAME TYPE (SEE DOOR AND FRAME ELEVATIONS) BB/1 SCHEDULED SCHEDULED SCHEDULED SCHEDULED SCHEDULED SCHEDULED SCHEDULED SCHEDULED 4" 6 3/4" 24" 11 5/8" SCHEDULED 2" 2" SCHEDULED 2" SCHEDULED 4" 2" SCHEDULED 2" SCHEDULED SCHEDULED SCHEDULED SCHEDULED DOOR AND FRAME ELEVATIONS DOOR TYPES: FRAME TYPES: A B C D 1 2 G3 E F COILING DOOR A. THIS DOOR SCHEDULE IS FURNISHED AS ASSISTANCE PROVIDED TO THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR EXAMINING THE WHOLE DRAWING SET AND SPECIFICATIONS TO COMPREHEND THE EXTENT OF DOOR AND FRAME INFORMATION INCLUDING QUANTITY OF EACH. IF A DOOR, FRAME OR SIDELIGHT SHOWN ON THE DRAWING IS OMITTED FROM THIS SCHEDULE, PROVIDE SAME AS REQUIRED FOR SIMILAR OPENINGS. B. FOR ANY DOOR REQUIRING A ROOM- IDENTIFICATION SIGN, SEE SPECIFICATION 10 14 00. LEGEND: GENERAL NOTES: AL ALUMINUM BZ DOOR BUZZER CR CARD OR PROXY READER CR(O) OPTIONAL CARD OR PROXY READER DS DOOR SENSOR (ELECTRICAL CONTACT) EP ELECTRONIC DIRECTORY WITH PHONE SERVICE FG FROSTED GLAZING HM HOLLOW METAL LG LAMINATED GLAZING PANIC PANIC HARDWARE SP SPANDREL PANEL SS STAINLESS STEEL ST STEEL TG TEMPERED GLAZING WD WOOD WG WIRED GLAZING 9'-0" 114" 9'-0" 114" KEYED NOTES: 1" CONDUIT TO TELECOMMUNICATIONS ROOM 15A 120V POWER CIRCUIT 5 2 5 5 6 6 1 USED FOR DOORS OVER 250' FROM TELECOM ROOM CEILING LINE 1" CONDUIT TO TELECOMMUNICATIONS ROOM 5 2 5 5 1 USED FOR DOORS WITHIN 250' FROM TELECOM ROOM 1. LOCK/STRIKE POWER SUPPLY IN 6"x6"x4" JUNCTION BOX. MOUNT ABOVE ACCESSIBLE CEILING ON SECURE SIDE OF DOOR. 2. 8x8x4 JUNCTION BOX. MOUNT ABOVE ACCESSIBLE CEILING ON SECURE SIDE OF DOOR. 3. PROXIMITY READER BACKBOX. 4" SQUARE BOX WITH SINGLE GANG ADAPTER RING. FLUSH MOUNT IN WALL. COORDINATE POSITION OF ROUGH-IN WITH CONSTRUCTION MANAGER BEFORE ROUGH-IN. 4. RESERVED 5. 1" CONDUIT 6. 3/4" CONDUIT 7. ALL CONDUITS SHALL INCLUDE A NYLON PULL STRING. PULL STRINGS SHALL BE TIED OFF AT EACH END. FOR CONDUITS ENTERING DOOR FRAME, PULL STRING SHALL CONTINUE THE LENGTH OF THE FRAME BOTH ACROSS AND DOWN (2 STRINGS) AND SHALL NOT BE TIED OFF. CEILING LINE GLAZING SCHEDULE NO. TYPE G1 G2 1" INSULATING CLEAR LOW-E 1" INSULATING CLEAR LOW-E TEMPERED SAFETY G3 WIRE (STAIR DOORS) DOOR AND FRAME SCHEDULE NOTES: 1. DOOR & FRAME SHALL BE EXTERIOR, EXTRA HEAVY DUTY DOOR & FRAME LEVEL 3. 2. DOOR & FRAME SHALL BE INTERIOR, HEAVY DUTY DOOR & FRAME LEVEL 2. 3. DOOR & FRAME SHALL BE EXTERIOR, HEAVY DUTY DOOR & FRAME LEVEL 2. 4. DOOR & FRAME TO HAVE TECH. CONDUIT ROUGH-IN (SEE #DrgID(ref)/ #LayID(ref) THIS SHEET) INSIDE WALL. ASSUME EVERY DOOR WILL REQUIRE BOX & CONDUIT FOR 15 AMP POWER CIRCUIT. SCALE: 1 1/2"= 1'-0" E1 HEAD DETAIL A601 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" D1 JAMB DETAIL A601 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" C1 SILL DETAIL A601 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" E2 HEAD DETAIL A601 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" D2 JAMB DETAIL A601 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" C2 SILL DETAIL A601 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" E4 HEAD DETAIL A601 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" D4 JAMB DETAIL A601 0 6'' 12'' 18'' SCALE: 1 1/2"= 1'-0" C4 SILL DETAIL A601 0 6'' 12'' 18'' COORDINATION NOTE THESE DETAILS ARE PROVIDED FOR INFORMATION ONLY FOR THE DOOR AND FRAME PROVIDER. SPECIFICATIONS REQUIRE THE DOOR AND FRAME PROVIDER TO PROVIDE RACEWAYS OR CONDUIT IN THE FRAMES FOR REQUIRED WIRING. FRAMES WILL BE GROUTED. REQUESTS FOR ATERNATIVES MUST BE APPROVED BY THE ARCHITECT. UPCOMING TECHNOLOGY AND ELECTRICAL DRAWINGS WILL INCLUDE COMPREHENSIVE INFORMATION FOR DOOR SPECIFIC REQUIREMENTS FOR THE ELECTRICAL CONTRACTOR. 10/6/2017 10/6/2017 04/16/18 Nick Mishler