Loading...
HomeMy WebLinkAboutP-401M 10 10 H H IB-1 SK-1 WD-1 L-1 WC-1 1" CW 3/4" HW 3/4" CW 3/4" CW 3/4" HW 3/4" CW 3/4" HW 3/4" HW 3/4" CW 3" W 3" W 3" W 3" W 3" W 2 5 4 2 4 5 4 DWH-1 12 6 6 7 8 9 10 11 CO 2"HD-1 18 20 21 25 26 27 10 10 H H WB-1 WC-1 TS-1 L-1 TS-1 L-1 1 1/2" V WC-1 1 1/2" V 1 1/2" V 13 14 15 13 14 13 15 16 19 28 29 10 10 1" CW 2" W 3" W 2" W 3" W 22 2 2 1 3 17 2" W 4" W 4" W W F 4" F 3" CW 4" F 23 3" CW 4" ST 24 ST A. REFER TO SHEET M-000 FOR PLUMBING SYMBOLS, LEGENDS AND ABBREVIATIONS. B. PROVIDE CLEANOUTS AT THE BASE OF EACH VERTICAL STORM, SOIL OR WASTE STACK. GENERAL PLUMBING NOTES 14168 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317.706.2075 www.enverityENG.com Project: Developer: Sheet Number: Engineer: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Enverity Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Park East Retail The Hamilton Building Carmel, Indiana 46032 THIS DOCUME NT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DE SIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HE RE IN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAME S R. STUTZMAN, AND PEDCOR DE SIGN GROUP, LLC. NO PART OR WHOLE OF THIS DE SIGN, THE SE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIE D, EXHIBITED, PHOTOGRAPHED, PUBLISHE D, MODIFIE D OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAME S R. STUTZMAN AND PEDCOR DE SIGN GROUP, LLC. © COPY RIGHT 2015 JAME S R. STUTZMAN, AIA, Carmel, Indiana. 100% Construction Documents JK GR P-401 Enlarged Plumbing Plans 08/31/17 08/31/17 N 1/4" = 1'-0" 2 Enlarged Plumbing Ground Level Plan N 1/4" = 1'-0" 3 Enlarged Plumbing Second Floor Plan 0 2' 4' 8' 0 2' 4' 8' N 1/4" = 1'-0" 1 Enlarged Plumbing Under 0 2' Floor 4' Plan 8' SHEET KEYNOTES 1 2"W UP. 2 3"W UP. 3 1"CW UP. 4 2"W, 1/2"CW & 1/2"HW UP. 5 1 1/2"W WITH DEEP SEAL P-TRAP, 1/2"CW & 1/2"HW UP. 6 1/2"CW UP. 7 1/2"CW & 1/2"HW DROP. 8 1/2"CW DROP. 9 2"W DN, 1 1/2"V TO AAV, 3/4"CW & 3/4"HW FROM BELOW. 10 1/2"CW DROP, ROUTE IN WALL TO WATER CLOSET. 11 2"W DN, 1 1/2"V UP TO AAV. REFER TO DETAIL #7/P-501. 12 REFER TO WATER HEATER PIPING DETAIL #3/P-501. 13 2"W DN, 1 1/2" RISE, 1/2"CW & 1/2"HW FROM BELOW. 14 1/2"CW FROM BELOW. 15 1/2"CW & 1/2"HW FROM BELOW. 16 2"V UP TO 3"VTR. 17 2"W WITH DEEP SEAL P-TRAP UP. 18 DISHWASHER, REFER TO DETAIL #7/P-501. 19 WASHING MACHINE DRAIN PAN (WMDP-1). 20 3" WASTE DOWN. 21 3/4"CW & 3/4"HW DOWN. 22 2"W, 3/4"HW & 3/4"CW UP. 23 3/4"HW & 3/4"CW UP. 24 4" STORM DRAIN LINE UP. 25 4" STORM DRAIN LINE UP AND DOWN. 26 1"CW FROM BELOW. 27 CW SERICE SUBMETER, SUBMETER FURNISH BY OWNER. 28 4' STORM DRAIN LINE DOWN. 29 4" STORM DRAIN LINE UP TO 4" ROOF DRAIN AND 4" OVERFLOW ROOF DRAIN. 04/16/18 Nick Mishler