HomeMy WebLinkAboutP-501CW THERMOMETER HW (120°F) DOMESTIC WATER HEATER (DWH) FLOOR 2"x3" HUB DRAIN (HD-1) DRAIN PAN TANK DRAIN ASME APPROVED TEMP. & PRESSURE RELIEF VALVE, TERMINATE RELIEF DRAIN LINE OVER FLOOR DRAIN THERMAL EXPANSION TANK CARRIER PIPE WATER STOP AND ANCHOR COLLAR WALL WALL SLEEVE MECHANICAL INTERLOCKING RUBBER LINKS TYPE WALL PENETRATION SEAL SLOPE RISER PIPE SAME AS SEWER 18"x18"x4" THICK CONCRETE PAD ROUND FLANGED HOUSING W/ HEAVY DUTY CAST IRON COVER LIKE J.R. SMITH 4251 FINISH GRADE CLEANOUT PLUG PIPE DOUBLE SUPPORT NUT LOCKING NUT HANGER ROD HANGER ROD LOCKING NUT SUPPORT NUT CLEVIS HANGER 14 GAUGE ZINC COATED SHEET STEEL SADDLE AT LEAST 12" LONG PIPE INSULATION INSULATION PREFORMED PIPE SUPPORT INSERT, SAME THICKNESS AS INSULATION MANUFACTURED FOR THIS PURPOSE. SINK SHUT-OFF VALVE REDUCER GARBAGE DISPOSAL 5/8" DRAIN HOSE 1 1/2" VENT 2" SAN DISHWASHER 1/2" HW CW SUPPLY HW SUPPLY CODE APPROVED AIR ADMITTANCE VALVE (AAV) COUNTERTOP INSTALL AS HIGH AS POSSIBLE UNDER THE COUNTERTOP 4" MIN. 12" PENETRATION BOOT & FLASHING TO MEMBRANE ROOFING BY ROOFING CONTRACTOR BASED ON CARLISLE U-8-A. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. PROVIDE STAINLESS STEEL CLAMPING BAND SURE SEAL WATER CUT-OFF MASTIC ROOK DECK - SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION. OPENING IN DECK BY PLUMBING CONTRACTOR. SEE DRAWINGS FOR SIZE INCREASER AS REQUIRED PIPE SIZE PER DRAWINGS TRAP SHALL NOT BE INSTALLED BELOW FLOOR BUT SHALL BE ROUGHED IN NOT LESS THAN 6" AND NOT MORE THAN 18" ABOVE FLOOR NO STANDPIPE RECEPTOR SHALL EXTEND MORE THAN 30" NOR LESS THEN 18" ABOVE ITS TRAP 1 1/2" VENT 1/2"CW 1/2"HW SHUTOFF VALVE WITH THREADED HOSE CONNECTION. 2" WASTE P-TRAP WITH UNION CONNECTIONS FLOOR LINE CLOTHES WASHER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO GUY GRAY SERIES RECESSED WALL BOXES. AT REFRIGERATORS - 12" AFF. AT ICE MACHINES - 12" AFF. AT COUNTERS - 1" ABOVE COUNTER BACK SPLASH, FOR COFFEE MAKER SUPPLY. VARIES REFRIGERATOR ICE MAKER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO OATEY SERIES RECESSED WALL BOXES. ANGLE STOP VALVE WITH THREADED CONNECTION FOR ICE MAKER TUBING 1/2"CW FLOOR LINE 1 1/2" WATER METER MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR. BFP-1 METER BFP-2 METER REDUCED PRESSURE ZONE TYPE BACKFLOW PREVENTER 4"CW TO BUILDING DOMESTIC WATER BOOSTER PUMPS PROVIDE REMOTE WATER METER READ OUTS, SEE FLOOR PLANS FOR LOCATION NEEDLE VALVE PRESSURE GAUGE FINISHED FLOOR SEE SPECIFICATIONS FOR PIPE SUPPORT REQUIREMENTS TYPICAL DRAIN FUNNEL WITH AIR GAP, TERMINATE DRAIN LINE OVER NEAREST FLOOR DRAIN 4"CW INCOMING SERVICE FLOOR SLEEVE COUPLING ADAPTOR (TYP) GATE VALVE (TYP) 1. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH UTILITY COMPANY'S REQUIREMENTS. WATER METER FURNISHED BY LOCAL UTILITY, CONTRACTOR INSTALLED. NOTE: CONTROL PANEL AND VFD'S HYDROPNEUMATIC TANK TYPICAL PUMP TYPICAL FLEXIBLE CONNECTOR NORMALLY OPEN FULL LINE SIZE BY-PASS TYPICAL SHUT OFF VALVE TYPICAL CHECK VALVE CW TO BUILDING SERVICE CW FROM BFP'S, AND WATER METERS NOTE: REFER TO SCHEDULE AND SPECIFICATIONS FOR ACTUAL QUANTITY OF PUMPS. TYPICAL PRESSURE GAUGE LOW SUCTION PRESSURE SWITCH BOOSTER PUMP PACKAGE MOUNTED ON STRUCTURAL FRAME SUPPORT 7'-0" ABOVE FINISH FLOOR HW CW THERMOMETER HW DOMESTIC WATER HEATER (DWH-2) TANK DRAIN ASME APPROVED TEMP. & PRESSURE RELIEF VALVE, TERMINATE RELIEF DRAIN LINE OVER FLOOR DRAIN THERMAL EXPANSION TANK WALL MOUNTED PLATFORM ASSEMBLY WITH DRAIN PAN AND SUPPORT BRACKETS EQUAL TO HODLRITE 30-SWHP-WM. INSTALL PER MANUFACTURER REQUIREMENTS PAN ASSEMBLY DRAIN, TERMINATE OVER MOP BASIN WITH 4" AIR GAP WALL 14168 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317.706.2075 www.enverityENG.com Project: Developer: Sheet Number: Engineer: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Enverity Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Park East Retail The Hamilton Building Carmel, Indiana 46032 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 100% Construction Documents JK GR P-501 Plumbing Details 08/31/17 08/31/17 NOT TO SCALE 3 Water Heater Piping Detail NOT TO SCALE 4 Wall/Floor Sleeve Detail NOT TO SCALE 5 Exterior Cleanout Detail NOT TO SCALE 6 Pipe Hanger Detail NOT TO SCALE 7 Dishwasher/Disposal Detail NOT TO SCALE 8 Vent Thru Roof Detail NOT TO SCALE 9 Clothes Washer Box Piping Detail NOT TO SCALE 10 Ice Maker Recessed Wall Box Detail NOT TO SCALE 1 Multiple Water Meter Piping Detail - Under Floor NOT TO SCALE 2 Water Booster Pump Piping Detail NOT TO SCALE 11 Water Heater Piping Detail 04/16/18 Nick Mishler