Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P-601
FLOOR DRAIN SCHEDULE SPECIFICATION SECTION 221316 MARK DESCRIPTION DRAIN BODY STRAINER INTEGRAL TRAP VANDEL PROOF SEDIMENT BUCKET FUNNEL INTEGRAL CLEANOUT MANUFACTURER WITH MODEL NUMBER NOTES MATERIAL OUTLET SIZE OUTLET TYPE MATERIAL SIZE TYPE HD-1 RESIDENTIAL UTILITY ROOM HUB DRAIN PVC AS NOTED - N/A N/A ROUND NO NO NO YES NO 2" x 3" HUB DRAIN 1, 2 NOTES: 1. DEEP SEAL P-TRAP 2. PROVIDE AND INSTALL DRAIN WITH 'SURE-SEAL', 'TRAP GUARD' OR 'QUAD CLOSE' OR SIMILAR SEWER GAS BACKUP PROTECTION. PLUMBING FIXTURE ROUGH-IN SCHEDULE SPECIFICATION SECTION 224000 MARK FIXTURE TYPE ROUGH-IN SIZES WASTE FIXTURE MOUNTING HEIGHT NOTES SIZE VENT SIZE CW SIZE HW SIZE WC-1 WATER CLOSET 3" 2" 1/2" - SEE SPECIFICATION 1, 3 L-1 LAVATORY 1 1/2" 1 1/2" 1/2" 1/2" SEE SPECIFICATION 1, 7 SK-1 DOUBLE COMPARTMENT STAINLESS STEEL SINK 1 1/2" 1 1/2" 1/2" 1/2" COUNTER MOUNTED 1, 7 WD-1 FOOD WASTE DISPOSER 1 1/2" - - - UNDER COUNTER SINK MOUNTED 1 IB-1 ICE MAKER SUPPLY UNIT BOX - - 1/2" - VARIES REFER TO DETAIL ON P-501 1 TS-1 TUB/SHOWER UNIT 1 1/2" 1 1/2" 1/2" 1/2" SEE SPECIFICATION 1 WB-1 CLOTHES WAHER SUPPLY UNIT BOX 2" 1 1/2" 1/2" 1/2" SEE SPECIFICATION 1, 9 HB-1 HOSE BIBB - - 3/4" - 24" 1, 3 WH-1 WALL HYDRANT - - 3/4" - 24" 2, 3 NOTES: 1. MOUNTING HEIGHT IS FROM FINISHED FLOOR. 2. MOUNTING HEIGHT IS FROM FINISHED GRADE. 3. FLOOR MOUNTED TANK TYPE WATER CLOSET. 4. INSTALL FLUSH VALVE HANDLE AT WIDE SIDE OF COMPARTMENT. 5. INSULATE DRAIN AND WATER SUPPLIES WITH INSULATION KIT. 6. 27" MINIMUM KNEE CLEARANCE WITH MINIMUM 9" TOE CLEARANCE. 7. PROVIDE THE CABINET SUPPLIER WITH APPROVED SHOP DRAWINGS SHOWING THE SIZE OF THE REQUIRED OPENING IN THE CABINET ENCLOSURE FOR THE PROPER INSTALLATION OF THE LAVATORY, TRIM, OR SINK. 8. REFER TO SPECIFICATION SECTION 221116. 9. PROVIDE AND INSTALL DRAIN WITH "SURE-SEAL", "TRAPGUARD", "QUAD-CLOSE" OR SIMILAR SEWER GAS BACK-UP PROTECITION. PLUMBING EQUIPMENT SCHEDULE MARK LOCATION MAKE AND MODEL NO. DESCRIPTION CAPACITY ELECTRICAL CHARACTERISTICS NOTES ET-1 VARIES AMTROL ST-5 THERMAL EXPANSION TANK 2.0 GAL. TOTAL VOLUME, 0.9 GAL. MAX. ACCEPT. - 1 WMP-1 VARIES SEE SPECIFICATIONS WASHING MACHINE DRAIN PAN 32"L x 27.5"W x 3"D. ID. - 2 NOTES: 1. REFER TO SPECIFICATION SECTION 223302. 2. REFER TO SPECIFICATION SECTION 224000. ELECTRIC WATER HEATER SCHEDULE SPECIFICATION SECTION 223301 MARK LOCATION ELECTRICAL DATA RECOVERY NOMINAL STORAGE CAPACITY (GAL.) UNIT WEIGHT (LBS.) MANUFACTURER WITH MODEL NUMBER NOTES HP KW VOLTS PHASE GPH RISE °F DWH-1 VARIES - 4.5 208 1 21 90 47 - BRADFORD WHITE, RE250L6 1, 2, 3 NOTES: 1. INSTALL DRAIN PAN UNDER THE WATER HEATER, PIPE DRAIN PAN AND WATER HEATER T&P VALVE TO HUB DRAIN OR FLOOR DRAIN. 2. WATER HEATER TO BE LOWBOY TYPE. 3. PROVIDE HEAT TRAPS ON THE INLET AND OUTLET OF THE WATER HEATER CONNECTIONS. BACKFLOW PREVENTER SCHEDULE SPECIFICATION SECTION 221116 MARK LOCATION SYSTEM TYPE DESIGN CAPACITY (GPM) PRESS. DROP (PSIG) SIZE (IN) MANUFACTURER WITH MODEL NUMBER NOTES NOTES: 1. USC APPROVED, FDA EPOXY COATED STRAINER, 7.5 FPS FLOW. 2. IN-LINE, INDEPENDENT CHECK VALVES WITH AN INTERMEDIATE RELIEF VALVE, NON-RISING STEM RESILIENT SEATED GATE VALVES. 3. PROVIDE UNIT WITH AIR GAP DRAIN ASSEMBLY, PIPE DRAIN TO NEAREST FLOOR DRAIN OR SINK. 4. MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR. 5. IN-LINE INDEPENDENT CHECK VALVES WITH INTERMEDIATE RELIEF VALVE, FULL PORT QUARTER-TURN RESILIENT SEATED BALL VALVE. 6. LEAD FREE. PUMP SCHEDULE SPECIFICATION SECTION 232123 MARK LOCATION SYSTEM TYPE DESIGN CAPACITY (GPM) DESIGN CAPACITY (FT. HD) MIN EFF. PUMP MOTOR DATA MANUFACTURER WITH MODEL NUMBER SUCT. NOTES (IN) DISCH (IN) HP RPM VOLTS PH NOTES 1. SKID MOUNTED PACKAGED DOMESTIC WATER PRESSURE BOOSTER SYSTEM. VARIABLE SPEED DRIVES, PROGRAMMABLE CONTROLS, SUCTION PRESSURE: 33 PSI. OVERALL SYSTEM PRESSURE BOOST OF 40 PSI. DISCHARGE PRESSURE OF 73 PSIG WITH A SUPPLY FLOW RATE OF 0 TO 140 GPM, UNIT TO BE PROVIDED WITH A STAINLESS STEEL OR COPPER INLET AND DISCHARGE MANIFOLDS. UNIT TO BE PROVIDED WITH A DIAPHRAGM TANK EQUAL TO B&G #PTA-12. 2. IAC 8-10-3 TITLE 327 INDIANA DEPARTMENT OF ENVIROMENTAL MANAGEMENT; EFFECTIVE JULY 19, 1985. EACH PUMP SHALL BE PROVIDED WITH CONTROLS TO PREVENT THE OPERATION OF PRESSURE BOOSTER PUMPS WHEN THE PUMP PRESSURE DROPS BELOW 20 PSIG. BFP-1 RISER G07 MAIN CW SYSTEM REDUCED PRESSURE ZONE ASSEMBLY 75 11 2" WATTS LF909 3, 4, 5, 6 BFP-2 RISER G07 MAIN CW SYSTEM REDUCED PRESSURE ZONE ASSEMBLY 75 11 2" WATTS LF909 3, 4, 5, 6 DWBP-1 RISE G07 DOMESTIC WATER DUPLEX DOMESTIC WATER PUMP PACKAGE 140 92.4 - - - 5 EA. 3600 480 3 GOULDS AQUA BOOST 2B504E-VS 1, 2 FD-2 HEAVY DUTY FLOOR DRAIN CAST IRON AS NOTED NO-HUB CAST IRON N/A ROUND NO NO YES NO NO J.R. SMITH #2142Y 1, 2 OSI-1 - STRIEMCO; OS-50 OIL/WATER/SAND SEPARATOR MAXIMUM 50 GPM FLOW, 52 GALLON LIQUID, 12.5 GALLON SAND, 34.1 GALLON OIL - 3 3. REFER TO SPECIFICATION SECTION 221323. DWH-2 SERVICE GARAGE 102 - 2.5 208 1 11 90 19 - BRADFORD WHITE, LE120L3-3 1 14168 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317.706.2075 www.enverityENG.com Project: Developer: Sheet Number: Engineer: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Enverity Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Park East Retail The Hamilton Building Carmel, Indiana 46032 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 100% Construction Documents JK GR P-601 Plumbing Schedules 08/31/17 08/31/17 04/16/18 Nick Mishler