Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M-501
DRYER BOX TO BE RECESSED INSIDE WALL 4-INCH ROUND DRYER CONNECTION ALL CONCEALED DRYER DUCTING MUST BE RIGID METAL. LENGTH OF CONCEALED RIGID METAL DUCTING SHALL NOT EXCEED 25 FEET. DEDUCT 5 FEET FROM THE ALLOWABLE LENGTH FOR EVERY 3.5" RADIUS 90 DEGREE ELBOW AND TWO AND A HALF FEET FOR EVERY 45 DEGREE FITTING. DRYER VENTING SHALL BE INDEPENDENT OF ANY OTHER SYSTEMS (CHIMNEYS OR EXHAUST VENTS). TERMINATION OF DRYER VENTING MUST BE TO THE EXTERIOR WITH A PROPER HOOD OF ROOF JACK EQUIPPED WITH A BACK-DRAFT DAMPER. SMALL ORIFICE METAL SCREENING SHOULD NOT BE A PART OF THE HOOD OR ROOM JACK AS THIS WILL ACCELERATE LINT ACCUMULATION AND BLOCKAGE. THE HOOD OPENING SHOULD POINT DOWN AND EXHIBIT 12 INCHES OF CLEARANCE BETWEEN THE BOTTOM OF THE HOOD AND THE GROUND OR OTHER OBSTRUCTION. FOR USAGE IN A ONE-HOUR WALL ASSEMBLY, UL REQUIRES THAT BATT INSULATION BE STUFFED AROUND THE DRYERBOX AND IN THE ENTIRE WALL CAVITY CELL. 4"Ø INLET (2) WASHABLE WIRE MESH FILTERS IN 12"x12", 16 GA. METAL HOUSING WITH BOTTOM ACCESS. 2" CHANNEL, 3/4" FLANGE 2 SIDES & TOP. 8"Ø OUTLET ACCESS PANEL 4"Ø INLET 12". 6". 12". CONDENSING UNIT DISCONNECT MOUNTED DIRECTLY ON CONDENSING UNIT SHEET METAL COVER POWER WIRING AND REFRIGERANT LINES FROM BUILDING UP THROUGH ROOF IN CUSTOM SHEETMETAL DOG HOUSE THREADED PVC SUPPORT PIPE ON EACH CORNER REFER TO STRUCTURAL PLANS FOR ROOF CONSTRUCTION ADJUSTABLE PVC CORNER SUPPORT ROOF INSULATION FASTEN SUPPORT AT CORNER - MINIMUM TWO AT EACH GALVANIZED SHEET METAL STORM COLLAR SECURED & CAULKED TO DUCT CURB BY G.C. CURB CAP-SECURE TO DUCT & CAULK WATERTIGHT SEE PLAN FOR DUCT CONTINUATION DO NOT OBSTRUCT GOOSENECK OPENING FOR DRYER EXHAUST APPLICATIONS HOLE THRU ROOF TO BE 1" LARGER THAN DUCT (BOTH WAYS) 36". M EXTERIOR WALL LOUVER BY DIVISION 15 GROUT AROUND VOIDS IN WALL AND SEAL AROUND LOUVER WATERTIGHT WITH NON-HARDENING SILICONE CAULK (INSIDE & OUTSIDE) SEAL ALL JOINTS IN DUCT WATERTIGHT MINIMUM 24" DEEP PLENUM SLOPE DOWN FOR DRAINAGE OUTDOOR AIR INTAKE DUCT BLANK SHEETMETAL BEHIND BOTTOM FIN MOTORIZED DAMPER EXTERNAL 2" THICK INSULATION ROOF MEMBRANE PIPE INSULATION BASE GALVANIZED CHANNEL SECURE PIPING TO SUPPORT WITH STRAP 10" MIN. FLOOR TO FLOOR STRUCTURE OR BULKHEAD ALL CONCEALED 4" DRYER DUCT SHALL BE NON-CORRUGATED SMOOTH METAL WITHOUT SCREWS. EXTERIOR WALL CAP WITHOUT SCREEN. 24"x10" TRANSFER GRILLES ON EACH SIDE, CENTERED ABOVE DOOR. (160 SQ. IN.) DRYER BOX IN SIDE WALL MOUNTED AT 4" A.F.F. 0' - 4" 1' - 9" JOINING AND ATTACHING FLEXIBLE DUCT SPECIFICATION: A. METALLIC FLEXIBLE DUCT SHALL BE ATTACHED USING A MINIMUM OF THREE #3 SHEET METAL SCREWS EQUALLY SPACED AROUND THE DUCTS CIRCUMFERENCE; DUCTS LARGER THAN 12"Ø SHALL HAVE A MINIMUM OF FIVE #8 SHEET METAL SCREWS. SCREWS SHALL BE LOCATED AT LEAST 1/2" FROM THE DUCT END. B. NON-METALLIC FLEXIBLE DUCT SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCT COLLAR EXCEEDS 12"Ø, THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. C. INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY-FABRICATED DUCTS SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SUPPLEMENTALLY SECURED WITH A DRAW BAND. D. FLEXIBLE DUCT SEALING SHALL BE A CLASS "B" SEAL FOR LOW PRESSURE SUPPLY. RECTANGULAR SUPPLY DUCT SPIN-IN FITTING W/VOLUME DAMPER FLEX DUCT-MAXIMUM 6'-0" LENGTH AND NO MORE THAN ONE (1) 90° BEND. SQUARE TO ROUND FITTING CEILING SUPPLY DIFFUSER 90° METAL ELBOW TYPICAL AT ALL DIFFUSER CONNECTIONS 14168 RM 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317.706.2075 www.enverityENG.com Project: Developer: Sheet Number: Engineer: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Enverity Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Park East Retail The Hamilton Building Carmel, Indiana 46032 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 20 15 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 100% Construction Documents JL M-501 Mechanical Details 08/31/17 08/31/17 NOT TO SCALE 1 Dryer Box Detail NOT TO SCALE 2 Dryer Vent Filter Box Detail NOT TO SCALE 3 Condensing Unit Detail NOT TO SCALE 4 Condensing Unit Support Detail NOT TO SCALE 5 Gooseneck Detail NOT TO SCALE 6 Louver Installation Detail NOT TO SCALE 7 Pipe Roof Support Detail NOT TO SCALE 8 Typical Dryer Vent Connection Detail NOT TO SCALE 9 Typical Supply Diffuser Installation Detail 04/16/18 Nick Mishler