Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M-601
CONDENSING UNIT SCHEDULE SPECIFICATION SECTION 236201 MARK LOCATION CONNECT TO UNIT NOMINAL TONS DESIGN AMB TEMP MIN AMB TEMP MIN. SEER ELECTRICAL DATA UNIT WEIGHT (LBS) MANUFACTURER WITH MODEL NUMBER NOTES MCA VOLTS PH CU-1 ROOF FCU-2 2.0 95 30 13 17.8 208 1 111 BRYANT BA13NA024 NOTES: FAN SCHEDULE SPECIFICATION SECTION 233423 MARK LOCATION FAN DATA MOTOR DATA ACCESSORIES UNIT WEIGHT (LBS) MANUFACTURER WITH MODEL NUMBER NOTES DESCRIPTION INTERLOCK WITH LOUVER DRIVE TYPE CFM TSP BHP RPM SONES HP VOLTS PH ROOF CURB DISCONNECT SWITCH GRAVITY BACKDRAFT DAMPER VIBRATION ISOLATORS BIRD SCREEN EF-1 SEE PLANS WALL MOUNTED - DIRECT 80 0.3 25.7W - 1.0 0.04 120 1 - - YES - - 9.0 BROAN LP80 1 EF-2 SEE PLANS ROOFTOP - DIRECT 50 0.2 0.15 1300 2.1 1/100 120 1 - YES YES NO YES 29 GREENHECK G-060-G EF-3 SEE PLANS ROOFTOP - DIRECT 50 0.2 0.15 1300 2.1 1/100 120 1 - YES YES NO YES 29 GREENHECK G-060-G EF-4 SEE PLANS ROOFTOP - DIRECT 50 0.2 0.15 1300 2.1 1/100 120 1 - YES YES NO YES 29 GREENHECK G-060-G EF-5 SEE PLANS ROOFTOP - DIRECT 50 0.2 0.15 1300 2.1 1/100 120 1 - YES YES NO YES 29 GREENHECK G-060-G EF-6 SEE PLANS ROOFTOP - DIRECT 3000 0.2 0.1 1725 19.7 1 120 1 - YES YES NO YES 67 GREENHECK G-143-VG EF-7 SEE PLANS WALL MOUNTED - DIRECT NOTES: 1. MOUNT IN SIDEWALL 2. RUN CONTINUOUSLY. ON/OFF AT CIRCUIT BREAKER. ELECTRIC UNIT HEATER SCHEDULE SPECIFICATION SECTION 238201 MARK LOCATION CONFIGURATION AIRFLOW (CFM) HEATING DATA ELECTRICAL DATA ACCESSORIES MANUFACTURER WITH MODEL NUMBER MIN NOTES KW MBH EAT LAT AMPS VOLTS PH DISCONNECT SWITCH INTEGRAL THERMOSTAT WALL BRACKET EWH-1 SEE PLANS WALL 100 3 10.2 40 134 14.4 208 1 YES YES NO QMARK AWH4404F 1,2 EUH-1 SEE PLANS SUSPENDED HEATER 350 5.0 17.1 50 95 6 480 3 YES YES YES QMARK MUH0541 1 EUH-2 SEE PLANS SUSPENDED HEATER 650 7.5 25.6 50 86 9 480 3 YES YES YES QMARK MUH074 1 EUH-3 SEE PLANS SUSPENDED HEATER 650 10 34.1 50 98 12 480 3 YES YES YES QMARK MUH104 1,3 EUH-4 SEE PLANS SUSPENDED HEATER 1320 20 68.2 50 98 24 480 3 YES YES YES QMARK MUH204 1 EUH-5 SEE PLANS SUSPENDED HEATER 2100 30 102.4 50 95 36 480 3 YES YES YES QMARK MUH504 1 NOTES: 1. MOUNT THERMOSTAT DIRECTLY ON HEATER. 2. PROVIDE SURFACE MOUNTING KIT. 3. NOT USED AS PART OF THIS SCOPE. GRILLES, REGISTERS AND DIFFUSERS SCHEDULE SPECIFICATION SECTION 233713 MARK MAX CFM DIMENSIONAL DATA THROW DATA PRESS. DROP (IN. WC.) MAX NC SOUND LEVEL MANUFACTURER WITH MODEL NUMBER NOTES FACE SIZE SLOT INFO CONN. SIZE DIRECTION DISTANCE @ NOM. CFM SG1 150 6"x6" 3/4" @ 45° - 2-WAY 11 0.12 20 PRICE 520 1,2,3 SG2 50 2"x12" 1/2" @ 45° - 2-WAY 5.5 0.01 <20 HART & COOLEY 420 1,2,3 SG3 125 6"x10" 1/2" @ 22° - 2-WAY 11 0.02 <20 HART & COOLEY 531 1,2,3 EG1 150 6"x6" 1/2"x1/2"x1/2" 6"x6" - - 0.04 <20 PRICE 80 1,2,4 TG1 275 24"x10" 3/4" @45° - - - 0.05 <20 PRICE 530 1 TG2 760 34"x10" 3/4" @45° - - - 0.04 <20 PRICE 530 1 NOTES: 1. COLOR TO BE SELECTED BY ARCHITECT. 2. PROVIDE APPROPRIATE MOUNTING FRAME FOR INSTALLATION. 3. PROVIDE INTEGRAL OPPOSED BLADE DAMPER. 4. PLENUM BOOT. LOUVER SCHEDULE SPECIFICATION SECTION 233300 MARK LOCATION TYPE WIDTH (INCHES) HEIGHT (INCHES) DEPTH (INCHES) FREE AREA (SQ. FT.) MAX. AIRFLOW (CFM) MAX AIR VELOCITY (FPM) BPWP (FPM) PLENUM BOX MANUFACTURER WITH MODEL NUMBER NOTES LV-1 SEE PLANS DRAINABLE 8.125 2.375 4 - 50 - - NO GREENHECK BVE 1,2 LV-2 SEE PLANS DRAINABLE 8.125 2.375 4 - 50 - - NO GREENHECK BVE 1,2 LV-3 SEE PLANS DRAINABLE 8.125 2.375 4 - 50 - - NO GREENHECK BVE 1,2 LV-4 SEE PLANS DRAINABLE 8.125 2.375 4 - 50 - - NO GREENHECK BVE 1,2 LV-5 SEE PLANS DRAINABLE 38 30 4 3.85 3000 799 989 YES GREENHECK ESD-435 1,3 NOTES: 1. LOUVER COLOR BY ARCHITECT 2. INCLUDE INSECT SCREEN. 3. INCLUDE FIRE DAMPER. APARTMENT ELECTRIC FAN COIL UNIT SCHEDULE SPECIFICATION SECTION 238200 MARK AREA SERVED CONFIGURATION SUPPLY DUCT RETURN DUCT FAN DATA FAN MOTOR DATA ELECTRIC HEATING COIL DATA DX COOLING COIL DATA FILTER DATA UNIT CONNECTION DATA DIMENSIONAL DATA UNIT WEIGHT (LBS) MANUFACTURER WITH MODEL NUMBER NOTES AIRFLOW (CFM) TSP TYPE RPM / SPEED HP NOM (ACTUAL) KW MBH EAT LAT STAGES TOTAL MBH SENS MBH EAT LAT TYPE MCA MOCP VOLTS PH DEPTH WIDTH HEIGHT DB WB DB WB FCU-1 SEE PLANS VERTICAL 16"x12" 20"x12" 763 0.5 DIRECT TAP 5 1/3 10 (7.5) 25.6 65 95.9 1 23.0 16.6 80 67 55 54 THROW AWAY 50.4 60 208 1 22-1/16" 14-5/16" 42-11/16" 112 BRYANT FB4CNP24 1,2,3 NOTES: 1. SINGLE POINT ELECTRICAL CONNECTION. 2. PROVIDE 7 DAY PROGRAMMABLE THERMOSTAT. 3. PROVIDE EXTRA SET OF FILTERS AND INSTALL UPON SUBSTANTIAL COMPLETION. 14168 RM 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 317.706.2075 www.enverityENG.com Project: Developer: Sheet Number: Engineer: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Enverity Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Park East Retail The Hamilton Building Carmel, Indiana 46032 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 100% Construction Documents JL M-601 Mechanical Schedules 08/31/17 08/31/17 NOTE 2. NOT USED NEED TO CONSIDER QUIETER OPTIONS; MIXED FLOW IMPELLER TYPE FANS, OR LARGER FAN W/LOWER RPM, OR ROOF TOP SOUND ATTENUATION WHAT ARE WE DOING FOR CURBS? SPECS 23 34 23, 2.02 indicates roof curbs shall be fabricated by the same manufacturer as the powered roof exhausters. 04 /16/18 Nick Mishler