Loading...
HomeMy WebLinkAboutS204 - PARKING GARAGE WALL & LINTEL PLANM J P 11.9 F.1 F.9 K B.1 B.2 15 15 14.1 14.1 10.8 9.9 12 12 9 9 8 8 7 7 6.1 5 5 3.9 0.5A 4 4 3 3 10 0.9 10 11 11 .95A .95A L 2 2 4.9 1 1 A A B B C C D D E E F F G G H H 6 6 13 13 0.7A 2.1 0.4A 18' - 0 5/8" 2' - 2 7/8" 16' - 3" 24' - 0" 1' - 3 5/8" 22' - 8 3/8" 1 1/2" 23' - 10 1/2" 24' - 0" 24' - 0" 23' - 10 1/2" 1 1/2" 24' - 0" 24' - 0 3/8" 1 1/8" 23' - 5 1/2" 21' - 10" 2' - 7" 14' - 6" 25' - 3 1/2" 5' - 6" 19' - 8" 2' - 7" 27' - 7" 2' - 8" 10' - 8" 40' - 8" 10' - 8" 3' - 0 1/2" 27' - 0 1/2" 2' - 9" 19' - 8" 2' - 5" 7' - 0 3/8" L1 L1 L1 L1 MW8G MW8G MW8G MW8G MW8G MW8G MW8G MW8G MW8G 14 S405 14 S405 13 S405 13 S405 1 13 12 11 10 9 8 7 6 5 4 3 2 A B C D E F G H 0.9A 14 0.9 J 0.6A 0.9A 0.9A 1/ S501 2/ S501 3/ S501 4/ S501 5/ S501 6/ S501 15.2 7/ S501 PROVIDE 1/4"x7"Wx8H" END PLATE w/ (2) 5/8"DIA HILTI KWIK BOLT III ANCHORS THIS END (GAGE 4" EMBED 2 3/4"). FIELD LOCATE COLUMN REINFORCING PRIOR TO ANCHOR INSTALLATION. DO NOT CUT OR DAMAGE COL REINF. (GALV) (GALV) (GALV) (GALV) SEE 11/S405 MW8 MW8 MW8 Q 1.5 N 1.6 M.5 N.5 4.7 4.8 MW8A MW8A MW8A L1 (GALV) (GALV) L1 13 S405 SIM 13 S405 14 S405 14 S405 SIM PROVIDE 1/4"x7"Wx8H" END PLATE w/ (2) 5/8"DIA HILTI KWIK BOLT III ANCHORS THIS END (GAGE 4" EMBED 2 3/4"). FIELD LOCATE COLUMN REINFORCING PRIOR TO ANCHOR INSTALLATION. DO NOT CUT OR DAMAGE COL REINF. POCKET LINTEL INTO EXISTING CMU WALL THIS END (GROUT CORES SOLID @ BRG) S201 1 4' - 2 1/2" 6' - 0" 4" 12' - 8 1/4" 3' - 1" 2' - 3" 19' - 8" 32' - 10" 10' - 8" 40' - 8" 10' - 8" 32' - 10" 19' - 8" 2' - 5" 3 3/4" 1' - 5 7/8" 3' - 2" 20' - 5 1/2" 1' - 11 7/8" 18' - 0 5/8" 2' - 2 7/8" 16' - 3" 1' - 3 7/8" 22' - 8 1/8" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 11 7/8" 5' - 6 5/8" 17' - 5 3/4" 23' - 6 5/8" 24' - 5" 14' - 6" 2 1/2" 15.00° 15.00° SEE 11/S405 MP1 MP1 MP1 MP1 EXTEND MASONRY PIERS FULL HEIGHT TO TOP OF PARAPET 11 S410 11 S410 12 S405 SEE 11/S405 STRUCTURE INSIDE CLOUDED LINES NOT IN SCOPE OF WORK SEE 11/S410 FOR LINTELS REQ'D 13 S410 1717 East 116th Street, Suite 200 Carmel, Indiana 46032 Structural Engineers 317-580-0402 www.mccomaseng.com McCOMAS ENGINEERING MEI 16054 Sheet Number: Sheet Title: Set Issue Date Last Revision Date: Drawn By: Sheet Issue Date Checked By: THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED H EREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN G ROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS M AY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. COPYRIGHT & OWNERSHIP OF DOCUMENTS Project Number: Engineer: PEDCOR DESIGN GROUP LLC Architecture / Project Management: 355 City Center Drive Carmel Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) By: Developer: Project: PARKING GARAGE WALL & LINTEL PLAN S204 Park East Retail Carmel, Indiana KLS CRR 12/22/16 09/22/16 SCALE: 3/32" = 1'-0" PARKING GARAGE WALL & LINTEL PLAN PLAN NORTH 0 2' 4' 8' 16' PARKING GARAGE WALL & LINTEL PLAN NOTES: 1. 'L1' INDICATES MASONRY LINTEL (SEE SCHEDULE ON S401A). 2. SEE S401A FOR SCHEDULES, GENERAL NOTES AND DETAILS. 3. SEE ARCH DRAWINGS FOR DIMENSIONS NOT SHOWN. 4. WALLS SHALL BE CONSTRUCTED USING LIGHT-WEIGHT CMU. MORTAR & GROUT SHALL BE NORMAL WEIGHT No. Date Description 1 Date 1 PHASE 2 04/16/18 Nick Mishler