Loading...
HomeMy WebLinkAbout18030172 State ReleaseELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/2 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on: January 12, 2018 Project number Release date 397230 01/12/18 Construction type Occupancy classification Scope of release V-B, I-B, SPK R-2, M, S-1, S-2, ADD Type of release Project name Street address City County ARCH ELEC FA MECH PLUM STR Standard HAMILTON 800 South Rangeline Road CARMEL HAMILTON To: Owner / Architect / Engineer PEDCOR DESIGN GROUP, LLC James Robert Stutzman AR00033126 355 City Center Drive Carmel IN 46032 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: 14B 4G0603AE 4G0603AE1 4G0603AA1 14B07066 14B1009934 14W09077 CDR is for three additions to parking garage: 1) Five attched townhomes (type VB construction) 2) One story retail (type IB construction) 3) One story service garage (type IB construction) This project has been reviewed under the 2014 Indiana Building Code. Detailed plans and specifications of the fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13) Detailed plans and specifications of the fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and 675 IAC 13-1-25. (N.F.P.A. 13R) This project release is for the building shell only and does not include the finish of one or more tenant spaces. Tenant space finish shall be filed as a new project in accordance with 675 IAC 12-6- 6 before commencing work. For retail area Fire walls shall extend from the foundation to a termination point at least 30 inches above both ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/2 Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above - stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Code review official Address (name,title of local official,street,city,state and ZIP code TONY RIGGS JIM BLANCHARD ONE CIVIC SQUARE CARMEL, IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov TRIGGS@DHS.IN.GOV Director, Division of Fire and Building Safety adjacent roofs in accordance with Section 706.6, IBC (675 IAC 13-2.6). At the R2 occupancy Usable spaces under stairways shall be protected in accordance with Sections 1009.9.3 and 1009.9.4, IBC (675 IAC 13-2.6). Upon completion of the installation of the fire alarm system, a satisfactory test of the entire system shall be made. All functions of the system or alteration shall be tested in accordance with Section 907.7, IFC (675 IAC 22-2.5). Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 3177057980, jrs@pedcor.net