HomeMy WebLinkAbout07 21 00 - Building InsulationMidtown West Studio M Architecture and Planning Carmel, IN November 10, 2017 07 21 00 - 1 SECTION 07 21 00 – BUILDING INSULATION 1.1 SUMMARY A. Provide Building Insulation and Vapor Retarders: 1) Thermal insulation in exterior walls, Kraft-faced type. a. EcoBatt by Knauf R 21HD (5.5 inches) Kraft faced batts – or equal. 2) Acoustical insulation at corridor walls / unit demising walls (one side) a. Thermafiber SAFB (3”) – or equal 3) Acoustical insulation between floors a. Thermafiber SAFB (3”) – or equal 4) Firesafing a. Thermafiber SAFB (thickness as required) – or equal 5) Under-slab / Foundation Wall a. Foamular 150 Rigid Extruded Polystyrene XPS Insulation at Foundation Walls and extended under slab for 2’-0” from exterior wall. - 2” thick 6) Attic Insulation at Loft units L1 – Sawtooth roof a. Blown-in Cellulose Type (R-38) or 10-11 inches 7) Extruded Polystyrene Board, Foamular CW25 Extruded Polystyrene (XPS) Board Insulation or equal. (ASI-002, 2-5-2018) END OF SECTION