HomeMy WebLinkAbout18040163 State ReleaseELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 1/2
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on:April 23, 2018
Project number Release date
395544 10/23/17
Construction type Occupancy classification
Scope of release
I-A, V-B, SPK R-2, M, B, A-2
Type of release
Project name
Street address
City County
ARCH ELEC FA FDN MECH
PLUM STR
Standard
Suite 2 Midtown West Apartments
2nd St SW & 3rd Ave SW
CARMEL HAMILTON
To: Owner / Architect / Engineer
Studio M Architecture and Planning
Joshua Joseph Mazur AR11300114
2 W Main
Carmel IN 46032
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
14B
4G0603AE
4G0603AE1
A2
4G0603AP
4G05A
14B0700
14B071659
14B11076212A
4G0603AA2
This project has been reviewed under the 2014 Indiana Building Code.
Detailed plans and specifications of the fire suppression system shall be filed with the required
application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and
675 IAC 13-1-8. (N.F.P.A. 13)
Detailed plans and specifications of the fire suppression system shall be filed with the required
application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and
675 IAC 13-1-25. (N.F.P.A. 13R)
An elevator installation permit shall be obtained from the Elevator Safety Division in accordance with
IESC (675 IAC 21-1-1). Please visit: http://www.in.gov/dhs/2374.htm
This release does not include pool installations in accordance with 675 IAC 12-6-7(19) and 8(a)(b).
Garage filed under CDR 395357
The Fire Prevention and Building Safety Commission has granted one or more variances which
apply to this project. 17-06-52
Fire resistive construction shall be maintained in accordance with Chapter 7, IBC (675 IAC 13-2.6).
Fire doors shall be self-closing or automatic-closing in accordance with Section 716.5.9, IBC (675
IAC 13-2.6).
Type A units shall be provided in R-2 occupancies in accordance with Section 1003, ICC A117.1,
2009 edition and Section 1107.6.2.1.2, Chapter 11, IBC (675 IAC 13-2.6).
This project release is for the building shell only and does not include the finish of one or more
tenant spaces. Tenant space finishes shall be filed as a new project or one or more partials in
accordance with 675 IAC 12-6-6 and 675 IAC 12-6-15 before commencing work. For the retail
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
0000000000, jmazur@studiomarchitecture.net
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
14B09051
14B071727
14B0907
14B10097
14B0707310B
areas
Standpipes shall be provided in accordance with Section 905.1 IBC (675 IAC 13-2.6) and NFPA 14
(675 IAC 13-1-9).
Fire dampers, smoke dampers, combination fire/smoke dampers, and ceiling radiation dampers
shall be provided in accordance with Section 717.2 through Section 717.7, IBC (675 IAC 13-2.6).
The fire alarm system shall be designed as specified in Section 907, IFC, and N.F.P.A. 72, in
accordance with Section 907, IBC (675 IAC 13-2.6).
NOTE: IBC 1022 A sign shall be provided at each floor landing designating the floor level
Stairway steps shall have rise and run dimensions in accordance with Section 1009.7, IBC (675 IAC
13-2.6).
One or more fire barriers or horizontal assemblies are being provided for the purpose of separating
mixed occupancies into different fire areas in accordance with Section 707.3.10, IBC (675 IAC 13-
2.6).
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will
be final, and you must comply with its requirements.
Code review official
Address (name,title of local official,street,city,state and ZIP code
TONY RIGGS
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL,IN 46032
DEPT OF COMMUNITY SERVICE
Fax & e-mail: 3175712499, jblanchard@carmel.in.gov