HomeMy WebLinkAboutA102.01900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office111/14/2016PLAN REVISIONS........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2016
Rick Starkey09/30/2016
LEFT
Allison II
2377.300.00.CPM
--
10/14/2016
PLOTTED: December 5, 2016 / Annie Ki / 2377-ALLISON II-CZ-BASE-EL-NC2G.DWG
A3-NC2G
3FB4.3Northern Craftsman 2G3 Car Front EntryPartial Floor and Utility Plans - 4" Exterior WallsELEVATION NC2G
ADDITIONAL 1ST FLOOR - HEATED 0
TOTAL 1ST FLOOR 1829
ADDITIONAL 2ND FLOOR - HEATED 0
TOTAL 2ND FLOOR 1508
TOTAL ELEV. HEATED 3337
ADDITIONAL GARAGE - 3 CAR FRONT 0
TOTAL GARAGE 609
ADDITIONAL BASEMENT 0
TOTAL BASEMENT 1251
FRONT PORCH 128
TOTAL ELEV. FOOTPRINT 2566
\A1;18'-8" - ℄ OF OPT. DOOR
TPTR
SCALE:1ST FLOOR PLAN - 4" WALLS1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
3 CAR GARAGE
9' CLG.OPT. TRAY CLG.DINING9' CLG..FOYER
9' CLG..
(2) 3060 SH
8'-0"x7'-0" O.H.G.D.16'-0"x7'-0" O.H.G.D.
OPT. 2020 FX
OPT. 2020 FX
OPT. 2020 FX
\A1;48'-0" - OVERALL\A1;19'-6"\A1;9'-10"\A1;8'-0"\A1;10'-8"\A1;1'-9"\A1;16'-0"\A1;1'-9"\A1;1'-3"\A1;8'-0"\A1;7"\A1;1{\H0.750000x;\S1#2;}"\A1;1'-8"\A1;4'-5"\A1;1'-8"\A1;1{\H0.750000x;\S1#2;}"
\A1;55'-0" - OVERALL
\A1;21'-0"
\A1;2'-4"
\A1;2'-8{\H0.750000x;\S1#2;}"\A1;2'-9"\A1;5'-5{\H0.750000x;\S1#2;}"\A1;12'-6{\H0.750000x;\S1#2;}"
\A1;1'-0"
\A1;12'-6{\H0.750000x;\S1#2;}"
\A1;10'-6"
\A1;1'-0"\A1;1'-8"
\A1;5'-4"
\A1;47'-0" TO CORNER
\A1;1{\H0.750000x;\S1#2;}"\A1;1'-8"\A1;10{\H0.750000x;\S1#2;}"
\A1;4'-2"
\A1;3'-0"
\A1;3'-0"
\A1;4'-1{\H0.750000x;\S1#2;}"
\A1;14'-3{\H0.750000x;\S1#2;}"
PORCH
\A1;1'-11{\H0.750000x;\S3#4;}"\A1;TO FRONT FACE \POF BEAM\A1;8{\H0.750000x;\S1#4;}"POST & BEAM PER STRUCTURAL PLANS
CL-07AD 2.3SIMILAR
3/0
WP/GFI S
R R
\A1;OPT. 2/8 SERVICE DOOR (SEE SPECS.) w/ 3'x3' CONC. STOOP
LINE OF FLOOR ABOVE 2x6 WALL
\A1;2'-8"
\A1;7'-4"
\A1;2'-0"\A1;6'-3{\H0.750000x;\S1#2;}"\A1;6'-3"
\A1;2'-8"
\A1;1{\H0.750000x;\S1#2;}"\A1;1'-8"
\A1;3'-6{\H0.750000x;\S1#2;}"
\A1;9'-2{\H0.750000x;\S1#2;}"\A1;1'-8"\A1;1{\H0.750000x;\S1#2;}"
\A1;55'-0" - OVERALL
TPTBOPT. TR
SCALE:2ND FLOOR PLAN - 4" WALLS1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
\A1;11'-2"\A1;6'-3"\A1;4'-11"\A1;3'-6"\A1;3'-4"\A1;6'-10"\A1;13'-8"\A1;6'-10"
\A1;11'-0"
\A1;3'-0"
\A1;48'-0" - OVERALL\A1;6'-10"
\A1;14'-10"
\A1;1'-0"(2) 3053 SH
8' CLG..BEDROOM 2 8' CLG..BEDROOM 3
8' CLG..WIC 8' CLG..BATH 2
LINE OF FLOOR BELOW
3040 SH2x6 WALL
2x6 WALL
8' CLG..WIC
\A1;1'-0"
\A1;47'-0" - OVERALL
\A1;6'-7"\A1;9'-9"
2030 SH (TEMP)
\A1;10'-6{\H0.750000x;\S1#2;}"
\A1;4'-3{\H0.750000x;\S1#2;}"
3053 SH
\A1;47'-0" - OVERALL
LIGHT & VENT SCHEDULE
ROOM NAME AREA
REQUIRED SUPPLIED
LIGHT VENT LIGHT VENT
BEDROOM 3 166.36 13.31 6.65 20.2 8.4
** REFER TO LIGHT & VENT SCHEDULE ON COVER SHT. FOR INFORMATION NOT SHOWN HERE.
05/04/18
Mike Sheeks