Loading...
HomeMy WebLinkAboutA102.01900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office111/14/2016PLAN REVISIONS........................ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 Rick Starkey09/30/2016 LEFT Allison II 2377.300.00.CPM -- 10/14/2016 PLOTTED: December 5, 2016 / Annie Ki / 2377-ALLISON II-CZ-BASE-EL-NC2G.DWG A3-NC2G 3FB4.3Northern Craftsman 2G3 Car Front EntryPartial Floor and Utility Plans - 4" Exterior WallsELEVATION NC2G ADDITIONAL 1ST FLOOR - HEATED 0 TOTAL 1ST FLOOR 1829 ADDITIONAL 2ND FLOOR - HEATED 0 TOTAL 2ND FLOOR 1508 TOTAL ELEV. HEATED 3337 ADDITIONAL GARAGE - 3 CAR FRONT 0 TOTAL GARAGE 609 ADDITIONAL BASEMENT 0 TOTAL BASEMENT 1251 FRONT PORCH 128 TOTAL ELEV. FOOTPRINT 2566 \A1;18'-8" - ℄ OF OPT. DOOR TPTR SCALE:1ST FLOOR PLAN - 4" WALLS1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN 3 CAR GARAGE 9' CLG.OPT. TRAY CLG.DINING9' CLG..FOYER 9' CLG.. (2) 3060 SH 8'-0"x7'-0" O.H.G.D.16'-0"x7'-0" O.H.G.D. OPT. 2020 FX OPT. 2020 FX OPT. 2020 FX \A1;48'-0" - OVERALL\A1;19'-6"\A1;9'-10"\A1;8'-0"\A1;10'-8"\A1;1'-9"\A1;16'-0"\A1;1'-9"\A1;1'-3"\A1;8'-0"\A1;7"\A1;1{\H0.750000x;\S1#2;}"\A1;1'-8"\A1;4'-5"\A1;1'-8"\A1;1{\H0.750000x;\S1#2;}" \A1;55'-0" - OVERALL \A1;21'-0" \A1;2'-4" \A1;2'-8{\H0.750000x;\S1#2;}"\A1;2'-9"\A1;5'-5{\H0.750000x;\S1#2;}"\A1;12'-6{\H0.750000x;\S1#2;}" \A1;1'-0" \A1;12'-6{\H0.750000x;\S1#2;}" \A1;10'-6" \A1;1'-0"\A1;1'-8" \A1;5'-4" \A1;47'-0" TO CORNER \A1;1{\H0.750000x;\S1#2;}"\A1;1'-8"\A1;10{\H0.750000x;\S1#2;}" \A1;4'-2" \A1;3'-0" \A1;3'-0" \A1;4'-1{\H0.750000x;\S1#2;}" \A1;14'-3{\H0.750000x;\S1#2;}" PORCH \A1;1'-11{\H0.750000x;\S3#4;}"\A1;TO FRONT FACE \POF BEAM\A1;8{\H0.750000x;\S1#4;}"POST & BEAM PER STRUCTURAL PLANS CL-07AD 2.3SIMILAR 3/0 WP/GFI S R R \A1;OPT. 2/8 SERVICE DOOR (SEE SPECS.) w/ 3'x3' CONC. STOOP LINE OF FLOOR ABOVE 2x6 WALL \A1;2'-8" \A1;7'-4" \A1;2'-0"\A1;6'-3{\H0.750000x;\S1#2;}"\A1;6'-3" \A1;2'-8" \A1;1{\H0.750000x;\S1#2;}"\A1;1'-8" \A1;3'-6{\H0.750000x;\S1#2;}" \A1;9'-2{\H0.750000x;\S1#2;}"\A1;1'-8"\A1;1{\H0.750000x;\S1#2;}" \A1;55'-0" - OVERALL TPTBOPT. TR SCALE:2ND FLOOR PLAN - 4" WALLS1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN \A1;11'-2"\A1;6'-3"\A1;4'-11"\A1;3'-6"\A1;3'-4"\A1;6'-10"\A1;13'-8"\A1;6'-10" \A1;11'-0" \A1;3'-0" \A1;48'-0" - OVERALL\A1;6'-10" \A1;14'-10" \A1;1'-0"(2) 3053 SH 8' CLG..BEDROOM 2 8' CLG..BEDROOM 3 8' CLG..WIC 8' CLG..BATH 2 LINE OF FLOOR BELOW 3040 SH2x6 WALL 2x6 WALL 8' CLG..WIC \A1;1'-0" \A1;47'-0" - OVERALL \A1;6'-7"\A1;9'-9" 2030 SH (TEMP) \A1;10'-6{\H0.750000x;\S1#2;}" \A1;4'-3{\H0.750000x;\S1#2;}" 3053 SH \A1;47'-0" - OVERALL LIGHT & VENT SCHEDULE ROOM NAME AREA REQUIRED SUPPLIED LIGHT VENT LIGHT VENT BEDROOM 3 166.36 13.31 6.65 20.2 8.4 ** REFER TO LIGHT & VENT SCHEDULE ON COVER SHT. FOR INFORMATION NOT SHOWN HERE. 05/04/18 Mike Sheeks