HomeMy WebLinkAbout04070217 Building PlansARCHITECT:
CSO
280 E. 96TH STREET, SUITE 200
INDIANAPOLIS, INDIANA 46240
Lr..jr� 19171 848.7800 19171 574.0957 FAX
CONTRACTOR:
VAW
Duke
CONSTRUCTION
600 E. 96th STREET
SUITE 100
INDIANAPOLIS, IN 46240
PHONE: (317)808-6000
INDEX OF DRAWINGS
• COVER
• A201 CONSTRUCTION PLAN & FINISH PLAN
• A202 REFLECTED CEILING PLAN & ELECTRICAL DATA PLAN
• A601 DOOR SCHEDULE - ELEVATIONS DETAILS
ArPWM As SUBM ED APPROVED tis MM MEM
smm DATE
CWMY
KEYPLAN
SCALE: NOT TO SCALE
EIGHT PARKWOOD CROSSING
SPECIFICATIONS AND GENERAL NOTES
0 CONTRACT CONDITIONS
0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION,
ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF
THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE
RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED
AS FOLLOWS:
3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND
FIELD CONDMONS AND REPORT DISCREPANCIES BEFORE
PROCEEDING WITH CONSTRUCTION,
3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE
RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES.
3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY
GOVERNMENTAL FEES, LICENSES AND INSPECTIONS,
3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING
ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND
WORKMANSHIP.
10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY
PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE
CONTRACTOR'S RESPONSIBILITY.
0,2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES,
RULES AND REGULATIONS.
0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD
QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF
THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION
IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED
PROJECT.
0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE
SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND
WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE
SPECIFIED CAPACITIES OF THE EQUIPMENT.
0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS
ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING
JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL
GOVERN THE WORK.
0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE
SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN
DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT
CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY
OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S
INTERPRETATION.
0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
1 GENERAL REQUIREMENTS
1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS
WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR
BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT.
1.2 THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS
INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE
AND "FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL
COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING,
AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE
WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR
REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS.
1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
WORKMANSHIP.
1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE
FOLLOWING ITEMS:
.1 METAL FABRICATIONS.
.2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS.
.3 DOORS, FRAMES AND HARDWARE.
.4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6" X 6' ACOUSTICAL
PANEL ).
.5 VCT FLOORING AND BASE ( COLOR SAMPLES ).
.6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ).
.7 PAINT ( 6" X 6" ON ACTUAL SURFACE ).
.8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ).
.9 SIGNAGE ( SAMPLE SIGN ).
.10 LIGHT FIXTURES ( CATALOG CUTS ).
1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES,
TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER
WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR
THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING
CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S
AGENT.
1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND
OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR
SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS,
TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT
EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE.
THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES
ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT
ADDITIONAL CHARGE TO THE PARTY AFFECTED.
1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS
CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS
TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS.
1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED,
SUBMIT THE FOLLOWING INFORMATION:
.1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF
PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES.
,2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED.
.3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL
CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO
ACCOMMODATE THE SUBSTITUTION.
.4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL
AFFECT THE CONTRACT SUM AND CONTRACT TIME.
1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME
FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING.
1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR
HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE
BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN
REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS.
1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL
CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION
EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE
PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION
NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND
MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN
THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE
INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL
PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD.
2 DEMOLITION
2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PIANS TO DETERMINE
EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE
BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW
WORK.
2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR
EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT,
OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION
TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND
SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED
TO ALLOW SUCH WORK, NO CHANGE ORDER WILL BE ISSUED FOR
ADDITIONAL WORK RELATED TO SUCH ACTIVITIES.
2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED
MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL
BE INCLUDED.
2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE
DRAWINGS.
2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE
ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED
FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND
METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEIN
FINISHES.
2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL
REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR
NOTED TO BE REPAIRED.
2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS.
2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS
REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK
IN SCOPE OF CONTRACT.
2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING
DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH ;S
ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS
SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT
THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS.
2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES
AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY
SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE -
OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED
CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO
DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS
PLUMBING, HVAC, ELECTRICAL, AND ARE PROTECTION SYSTEMS.
CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ra A
RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET.
2.11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT,
SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE
DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN.
5 METAL FABRICATIONS
5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICA110
OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS
REQUIRED TO COMPLETE WORK.
6 WOOD AND PLASTIC
6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE 'CONSTRUCTION
GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE
CONTENT.
6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE
EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA
C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32".
6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND
PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA
C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH
CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING
JURISDICTION.
6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH 'PREMIUM GRADE' AWI
STANDARDS.
.1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR
TO FABRICATION OF MULTIPLE UNITS.
6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH
NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS).
.1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL
SURFACES.
.2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE
ELECTRICAL OR DATA OUTLET LOCATIONS.
6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4008 FOR
PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS.
.1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS:
GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28
(0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL.
THICKNESS).
.2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28.
.3 CABINET HARDWARE SCHEDULE:
.1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES"
BY GRASS OR EQUAL.
.2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER,
#4483 OR EQUAL AS MANUFACTURED BY STANLEY.
.3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH
MINIMUM 8 LBS. PULL; i SP 45 OR SP 46 DR EQUAL AS
MANUFACTURED BY STANLEY.
.4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES
WITH POSITIVE STOP AND LOCKOUT POSITION, WITH
HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS
MANUFACTURED BY KNAPE & VOGT.
.5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF
SUPPORTS CONSTRUCTED OF HIGH IMPACT INJEC11ON
MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED
SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT
OR EQUAL
SUITE 104
6.7
MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH
9.10
ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE
PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS.
RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS
6.8
DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING,
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED
BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE,
WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY
ELECTRICAL SYSTEMS.
OPERATING FOR TEN DAYS.
GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF
6.9
INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND
PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A
STRAIGHT WITH NO DISTORTIONS.
CERTIFIED ENGINEER.
6.10
JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS
WIDTH NOT TO EXCEED 1/8 U.O.N.
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN)
6.11
GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL
DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND
OUTLETS.
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK.
7
JOINT SEALERS
7.1
ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL
AND FIXTURES:
15/16.5
DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
.1 "DOW CORNING 786"; DOW CORNING CORP.
SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR
.2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO.
15/16.6
OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED
.3 "863 1345 WHITE"; PECORA CORP.
WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED.
.4 "PROGLAZE WHITE"; TREMCO CORP.
EQUIPMENT.
.5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS
SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE
7.2
ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING
15/16.8
DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND
SURFACES:
INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
.1 "CHEM -CALK 600'; BOSTIK CONSTRUCTION PRODUCTS DIV.
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
.2 "AC -20"; PECORA CORP.
INSTALLATION SHALL OCCUR.
15/16.9
.3 "SONOLAC'; SONNEBORN BUILDING PRODUCTS
OUTLETS UNLESS
, LES OTHERWISE NOTED.
.4 'TREMCO ACRYLIC LATEX 834'; TREMCO, INC.
ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
8
DOORS AND WINDOWS
8.1
INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS
WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY
NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER.
8.2
INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED
IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH.
15/16.13
8.3
DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO
AND LOCKSETS.
8.4
GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048
GENERAL NOTES
GN.1
REQUIREMENTS FOR HEAT -STRENGTHENED GLASS.
9
FINISHES
PROCEEDING WITH CONSTRUCTION.
9.1
GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645.
A. TO FINISHED FACE OF GYPSUM BOARD.
.1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS,
AT CEILING. USE PREFORMED OUTSIDE CORNERS.
9.2
GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE "X" TAPERED
SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND
GNA
TERMINATE WALLS AT UNDERSIDE OF CEIUNG UNLESS INDICATED
JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE
OTHERWISE.
GN.5
WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS.
LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS
.1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH
WITH CONSTRUCTION.
MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA -
CONTRACTOR SHALL PROVIDE CHAD( LINES DELINEATING WALL LAYOUT
216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND
9.11
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
FINISHING OF GYPSUM BOARD.
OBSERVATION.
9.4
CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM
LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
DAMAGED OR SOILED TILES.
FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON-
.1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS
CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED,
GN.8
IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL
CLOSE -IN OF WALLS,
REFLECTED CEILING PLAN SHALL GOVERN.
10
.2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN
PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE.
LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS
101
UNLESS NOTED OTHERWISE.
9.5
INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR
ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY
CASED OPENING UNLESS NOTED OTHERWISE.
.1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET
MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH
CARPET.
9.6
RESILIENT FLOORING:
A UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS
ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT
OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO
AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER.
.2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID
BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING
ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS.
9.7
USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL
HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM
SURFACE VARIATION OF 9' IN 10 FEET, NON -CUMULATIVE.
9.8
CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING
STANDARDS:
FLAMMABILITY: ASTM 2859
SURFACE BURNING: ASTM E84
SMOKE DENSITY: ASTM E662
SOUND ABSORPTION: ASTM C423
FADE RESISTANCE: AATCC 16E
STATIC RESISTANCE: AATCC 134
WARRANTY: 10 YEARS
.1 INSTALL BROADLOOM CARPET BY DIRECT GLUE.
INDIANAPDX.IS, INDIANA
PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY,
REINSTALL SUCH ITEMS.
.1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT
SYSTEMS BASED ON DEVOE TO ESTABLISH OUALITY STANDARD
FOR THE VARIOUS SUBSTRATES, AS INDICATED.
1. FERROUS METAL:
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SEMI -GLOSS ENAMEL
2. NON-FERROUS METAL-
A.
ETALA. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #417+02 METALCLAD ACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC
SEMI -GLOSS FINISH
3. FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
REDUCIBLE ACRYLIC DRY FOG COATING
4. NON-FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
REDUCIBLE ACRYLIC DRY FOG COATING.
8. WOOD:
A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX
PRIMER -SEALER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SEMI -GLOSS ENAMEL
B. STAIN -VARNISH RUBBED FINISH:
1. FILLER: 1 COAT #4800 WONDER WOODSTAIN
PASTE WOOD FILLER (OPEN GRAIN WOODS).
2. STAIN: 1 COAT 196XX WONDER WOODSTAIN
ALKYD STAIN.
3. SEALER: 1 COAT #4900 WONDER WOODSEALER
QUICK DRY SEALER.
4. FINISH: 2 COATS #4600 WONDER WOODSTAIN
ALKYD SATIN VARNISH,
10. GYPSUM WALLBOARD:
A. ACRYLIC LATEX SATIN ENAMEL FINISH:
1. PRIMER: 1 COAT #50801 WONDER TONES LATEX
PRIMER -SEALER.
2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC
LATEX SATIN ENAMEL
13, PRECAST CONCRETE:
A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS)
1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC
LATEX HOUSE PAINT PRIMER.
2. FINISH: 1 COAT #441101 DEV-VO-TEX LATEX
TEXTURE COATING.
WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND
WITHOUT WRINKLES, GAPS OR OVERLAPS.
.1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT
ACCEPTABLE.
.2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CANERS AND 6" FROM
OUTSIDE CORNERS.
ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO
BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR' SERIES,
SEMI RECESSED, DUO -PANEL, FIELD PAINTED.
I;wRMEL FIRE DEPARTMENT
PLAN REVIEW
Received 2'Z wed
Released
St. Permit0 63 i[y Permit'Lazo
w Ufa
Reviewed By.-
Title:
y.Title:
CITY OF CARMEL - CLAY TOWNSHIP Dept. of Community Services
Building & Code Enforcement
One Civic Square - First Floor
Carmel, IN 46032
Plan Authentication Certification and Agreement
As the authorized agent responsible for obtaining a permit or permits', I certify that these plans
ore identical to those released for construction by the Indiana Dept. of Fire d Building Services. I
also understand that if it is determined that these plans are not identical, a STOP WORK ORDER
will be served, as required and the Ordinances referenced below.
)Q
AUTHORIZED SIGNATURE DATE
' Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 and 29.4.3
entitled "Administration". Required by Cannel Clay Township Zoning Ordinance, Section 31.1 entitled "Violations and
penalties". t
s:pertnits/forms/authentication Aug 2001
12 FURNISHINGS
12.1 CASEWORK:
.1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE
FOLLOWING:
.1 IMPERIAL CABINET CO., INC,
.2 MERILLAT INDUSTRIES, INC.
.3 YORKTOWNE CABINETS
15/16 MECHANICAL AND ELECTRICAL
15/16.1
MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND
ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE
RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS
ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE,
INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND
ELECTRICAL SYSTEMS.
15/16.2
GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF
DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND
PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A
CERTIFIED ENGINEER.
15/16.3
IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN)
AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL
DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK.
15/16.4
SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE
OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL
COORDINATE WITH OTHER CEILING COMPONENTS.
15/16.5
DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR
OWNER'S AGENT,
15/16.6
OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED
WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED.
VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED
EQUIPMENT.
15/16.7
SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
15/16.8
DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND
INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
INSTALLATION SHALL OCCUR.
15/16.9
DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF
OUTLETS UNLESS
, LES OTHERWISE NOTED.
15/16.10
ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE
IVORY.
15/16.11
WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY
SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL
PROVIDING PROPER ACCESS TO RECEPTACLES.
15/16.12
IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
FOR SPECIFIC LOCATION.
15/16.13
CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO
OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN"
CONSTRUCTION.
GN
GENERAL NOTES
GN.1
CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND
REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO
PROCEEDING WITH CONSTRUCTION.
GN.2
DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED:
A. TO FINISHED FACE OF GYPSUM BOARD.
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS,
C. TO TOP OF FINISHED FLOORS.
D. TO BOTTOM OF FINISHED CEILINGS.
GN.3
SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
EXISTING CONSTRUCTION AND WALL TYPES.
GNA
TERMINATE WALLS AT UNDERSIDE OF CEIUNG UNLESS INDICATED
OTHERWISE.
GN.5
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING
WITH CONSTRUCTION.
GN.6
CONTRACTOR SHALL PROVIDE CHAD( LINES DELINEATING WALL LAYOUT
FOR THE ARCHTTECT'S OBSERVATION WITH REGARD TO DESIGN INTENT.
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
OBSERVATION.
GN]
FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT
LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON-
CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED,
GN.8
CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO
CLOSE -IN OF WALLS,
GN.9
SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT
PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE.
PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE.
PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED
TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL
JUNCTION BOXES ARE NOT PERMITTED.
GNAO
ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY
TENANT.
07/06/04
CSO #24199C
CONSTRUCTION PLAN
SCALE: 1/80P = 1'-0"
II
OO O O INTERVIEW INTERVIEW INTERVIEW INTERVIEW
C3 P1 C3 P1 ROOM ROOM ROOM ROOM
OFFICE C1
OFFICE OFFICE 61 OFFICE Bt — 111 107 106 toy 104
117 116 115 C3 P1 B2OC1 OC182 82SC1 62 CONFERENCE
CC3 P1
103
8 61 W1 W1 W1 W1 C1 62
W1 C1
D82ORRIDOR
C3 P1
OFFICE B1
118
C3 `P1
OFFICE 81
119
8
(DIS
OPEN
OFFICE
114
FINISH PLAN
SCALE: 1/8" = 1'-0"
GENERAL CONSTRUCTION NOTES:
CONSTRUCTION PLAN NOTES:
A.
DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED
FPt
ALIGN FINISHED FACES.
PATTERN: DENSE PATI. LOOP
OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE
COLOR: REQ.#912-05030-8
PAINT
LOCATION: RECEPTION, CONE, INTERVIEW
VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS.
CARPET — DIRECT GLUE
W
0
N
MFG: J & J INDUSTRIES
Z
0
F
FP2
CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS. USE SEALANT AT MULLIONS
B.
SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES.
LOCATION: 12" RECEPTION BORDER
FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY
CARPET — DIRECT GLUE
mm
MFG: J & J INDUSTRIES
DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 6/A601.
C.
ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL
CONSTRUCTION.
FP3
PROVIDE l4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED REFRIGERATOR. VERIFY EXACT
LOCATION: GENERAL
vcT1
VINYL COMPOSITION TILE
LOCATION OF ALL APPLIANCES REQUIRING A WATER SOURCE WITH TENANT.
D.
REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH
ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE.
FP4
REFRIGERATOR, VENDING MACHINE, &WATER COOLER PROVIDED AND INSTALLED BY TENANT. G.C. TO
C
Y o Q
LOCATION: BREAK, TELE/DATA, STORAGE
PROVIDE POWER SOURCE FOR APPLIANCES. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S
E.
ALL NEW TRACK AND TRIM AT WALL CEILING CONDITIONS SHALL MATCH EXISTING COLOR AND
VINYL BASE —4" COVE BASE
MANUAL.
MANUFACTURER: JOHNSONITE
MATERIAL TO PROVIDE CONTINUOUS/CONSISTENT APPEARANCE THROUGHOUT CEILING.
FP5
ENTIRE WALL TO HAVE 3/4" FRT PLYWOOD PHONE BOARD, MOUNTED 20" A.F.F. TO CEILING. PHONE
BOARD
% F.
PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE
FINISH: (2) COATS STAIN, (2) COATS
TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL
FINISH.
CLEAR SEMI—GLOSS
MOUNTED ITEMS.
POLYURETHANE SEALER. PROVIDE
50
r G.
EXISTING DOORS AND DOOR FRAMES TO BE REUSED ARE TO BE CLEANED AND REINSTALLED AT
FP6
NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF
CABINET AT 54"
%
COMPLETION OF CONSTRUCTION. CONTACT DESIGNER TO REVIEW AND APPROVE DOORS THAT ARE
Drawing Number:
AFF. PAINT TO MATCH ADJACENT WALL SURFACE. FIRE EXTINGUISHER CABINET TO
MATCH BUILDING STANDARD, UNLESS
Of Sheets
QUESTIONABLE FOR REUSE.
A/E Job Number:
NOTED OTHERWISE.
' H.
'
NEW DOOR AND FRAME NUMBERS CORRESPOND TROOM NUMBERS. WHERE MORE THAN ONE
F 77
NEW BASE AND UPPER CABINETS WITH SINGLE BOWL STAINLESS STEEL SINK (TO MEET ADA
REQUIREMENTS). CABINETS TO BE TIMBERLAKE BAINBRIDGE. PLASTIC LAMINATE
DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A).
A
COUNTERTOP TO BE
FORMICA FOLKSTONE CELECTA #692-58.
= I.
ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL.
FP8
COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE.
J.
ALL NEW DOORS SHALL ALLOW 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED
VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL.
OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS.
FP9
. 3 4" WHITE MELAMINE SHELVES ON HEAVY DUTY KV 187-78" STANDARDS & KV 87-12"
WACKETS.
K.
ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT
PROVIDE ADDITIONAL BLOCKING AS REQUIRED. REFER TO SECTION 7/A601.12"d
WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY
P1
RECEPTION LEDGE ON PARTIAL HEIGHT WALL. REFER TO DETAIL 1/A601.
PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE
EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR
REVIEW OF AESTHETIC PURPOSES ONLY.
P1
PLASTIC LAMINATE WORK COUNTER WITH (3) 48" W. TIMBERLAKE BAINBRIDGE BASE CABINETS BELOW,
PLASTIC LAMINATE SHELF ABOVE. REFER TO ELEVATION 3/A601.
L.
RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH
P1
REMOVE SECTION OF EXISTING CORRIDOR WALL TO PROVIDE NEW ENTRY TO SUITE.
DESIGNER.
M.
APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL AND AT ALL
WALL LEGEND:
COUNTERTOPS AND BACKSPLASH JUNCTURES.
NOTE:
ALL WALLS TO BE W1 UNLESS NOTED OTHERWISE.
N.
BUILDING OWNER AND/OR G.C. TO PROVIDE MINIBLINDS AT ALL PERIMETER WINDOWS. EXISTING
MINIBLINDS TO BE RELOCATED ARE TO BE STORED DURING CONSTRUCTION PHASE, THEN
= _ = EXISTING CONSTRUCTION TO BE REMOVED
CLEANED AND REINSTALL UPON COMPLETION OF CONSTRUCTION.
EXISTING PARTITION TO REMAIN
0.
FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS
NEW WALL PARTITION
SCHEDULED.
NEW LOW WALL PARTITION
P.
ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE
PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES.
W1
—
2-1/2" 25 GAUGE METAL STUDS @24"O.C. WITH 5/8" GYPSUM WALL BOARD
EACH SIDE. WALLS TO
EXTEND TO UNDERSIDE OF CEILING.
Q.
ALL NEW LOCATIONS TO BE
KTE DE
VERIFIED WITH TENANT IN FIACES
DEANDEWITHI/RESP COTMTO�NEWEEL CTRCALTLAYOUT. GROMMET
W2
2-1/2" 25 GAUGE METAL STUDS @24"O.C. WITH 5/8" GYPSUM WALL BOARD
COLOR TO BE: BLACK.
—
EACH11n ,J'
GENERAL FINISH NOTES:
A. ALL DOORS TO BE FINISHED WS1.
B. ALL DOOR FRAMES TO BE PAINTED P2.
C. ALL NEW WOOD TRIM TO BE FINISHED WS1.
D. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPET IN PROJECT SCOPE FOR
REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING
INSTALLATION.
E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE
FEATHERED AS REQUIRE OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH
TRANSITION FROM FINISH TO FINISH.
F. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND
VINYL TILE TRANSITIONS TAKE PLACE.
G. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER.
SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW.
H. BASE IN REST ROOMS MUST BE MINIMUM 5" HEIGHT TO MEET BOARD OF HEALTH CODE.
I. PAINT NEW PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT. COLOR TO MATCH
ADJACENT WALL FINISH.
J. PAINT ALL EXPOSED METAL SURFACES (i.e.. GRILLS, HEATERS, AND FIRE EXTINGUISHER
CABINETS) TO MATCH ADJACENT SURFACE.
K. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW
MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD.
L. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK TO DESIGNER FOR
REVIEW AND APPROVAL BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS.
M. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH
INFORMATION.
N. PROVIDE FULL HEIGHT OR PARTIAL HEIGHT, CLEAR OR COLOR CORNER GUARDS. REFER
TO FINISH PLAN FOR LOCATIONS.
FINISH PLAN NOTES:
FN1 NEW BASE AND UPPER CABINETS TO BE TIMBERLAKE BAINBRIDGE. PLASTIC LAMINATE
COUNTERTOP TO BE FORMICA FOLKSTONE CELECTA #692-58.
&OAK RECEPTION LEDGE ON PARTIAL HEIGHT WALL. PLASTIC LAMINATE WORKSURFACE.
REFER TO DETAIL 1/A601.
FN3 PLASTIC LAMINATE WORK COUNTER WITH (3) 48" W. TIMBERLAKE BAINBRIDGE BASE
CABINETS BELOW, PLASTIC LAMINATE SHELF ABOVE. REFER TO ELEVATION 3/A601.
FN4 (4) 12"dp. 3/4" WHITE MELAMINE SHELVES. REFER TO SECTION 7/A601.
FN5 MATCH EXISTING CORRIDOR FINISHES IN NEW ENTRY ALCOVE.
SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2 1/2 N,
SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL,
INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF
WALL.
W3 NEW LOW WALL CONSTRUCTION TO BE: 2-1/2" 25 GAUGE METAL STUDS
@16"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. REFER TO SECTION
1/A601 FOR EXACT HEIGHT OF LOW WALLS.
M
W4 2-1/2" 25 GAUGE METAL STUDS @24" O.C. WITH 5/8" GYPSUM WALL BOARD 6
ONE SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. — t --�
W5 NEW WALL CONSTRUCTION TO MATCH ADJACENT PARTITION CONSTRUCTION.
DENOTES AREA NOT IN CONTRACT
DENOTES NEW MILLWORK
NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE
FINISH LEGEND:
FLOORCOVERINGS
W1
CARPET — DIRECT GLUE
C1
MFG: J & J INDUSTRIES
Landscape Architecture
PATTERN: DENSE PATI. LOOP
Corporate Office
COLOR: REQ.#912-05030-8
PAINT
LOCATION: RECEPTION, CONE, INTERVIEW
GDC2
CARPET — DIRECT GLUE
W
0
N
MFG: J & J INDUSTRIES
Z
0
F
PATTERN: DENSE CUT PILE
o
0
COLOR: REQ.#912-05030-9
P2
LOCATION: 12" RECEPTION BORDER
C3
CARPET — DIRECT GLUE
mm
MFG: J & J INDUSTRIES
O (15 0
PATTERN: DENSE LOOP
PLASTIC LAMINATE
COLOR: REQ.#912-05030-3
MANUFACTURER: FORMICA
LOCATION: GENERAL
vcT1
VINYL COMPOSITION TILE
FINISH: MATTE
MFG: ARMSTRONG
wst
PATTERN: IMPERIAL TEXTURE
�
COLOR: #51915 CHARCOAL
Y o Q
LOCATION: BREAK, TELE/DATA, STORAGE
BASE
POLYURETHANE SEALER.
61
VINYL BASE —4" COVE BASE
O :D 0-
W 3�zz
MANUFACTURER: JOHNSONITE
0 _
a Z �
COLOR: CB -18 NAVY BLUE
62
OAK WOOD BASE — 4" X 1"
FINISH: (2) COATS STAIN, (2) COATS
z
CLEAR SEMI—GLOSS
V
POLYURETHANE SEALER. PROVIDE
50
FURNITURE GRADE FINISH,
STAIN: MINWAX #225 RED MAHOGANY.
WALLCOVERING
W1
MFG: KOROSEAL VICRETEX
Engineering
PATTERN: DAKOTA
Landscape Architecture
COLOR: EAGLE FEATHER DK -21-07
Corporate Office
LOCATION: RECEPTION, CONE, INTERVIEW
PAINT
0
1
P1
MFG: SHERWIN WILLIAMS
W
0
N
COLOR: HARMONY #SW1004 PURE WHITE
Z
0
F
FINISH: EGGSHELL LATEX
o
0
LOCATION: GENERAL
P2
MFG: SHERWIN WILLIAMS
COLOR: #SW1233 ELITE GREY
mm
FINISH: SEMI—GLOSS ALKYD ENAMEL
O (15 0
LOCATION: DOOR FRAMES
PLASTIC LAMINATE
PL1
MANUFACTURER: FORMICA
COLOR: FOLKSTONE CELECTA 692-58
a
FINISH: MATTE
WOOD FINISH
wst
OAK WOOD VENEER
�
FINISH: (2) COATS STAIN, (2) COATS
Y o Q
CLEAR SEMI—GLOSS
W V
POLYURETHANE SEALER.
o
STAIN: MINWAX #225 RED MAHOGANY.
NOTE:
WHEN ORDERING CARPET, SIDEMARK "ALLEGIS GROUP ACCT."
ue
REALTY CORPORATION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: (317) 808-6000
Fax: (317) 808-6797
w..
u
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
0
1
a
n
0
W
0
N
Z
0
F
C
0
o
0
CK
O O
e N
mm
m
O (15 0
N�
U
c)r
z
a
CL
� s
z Cal
�
zZ
`�
Y o Q
z as
W V
o z
o
0 CC �J J
d.
O :D 0-
W 3�zz
a ,e Q O
0 _
a Z �
a �
0
z
O
V
Ce r
U
50
16
��OQ910Q3fi, j
STATf or
�y' e
ANS'
It
Drawing Number:
A201
Of Sheets
Duke Job Number:
A/E Job Number:
24199C
w..
u
GENERAL CEILING NOTES: REFLECTED CEILING LEGEND: U E
REALT coRPow►nON
A. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD NEW BUILDING STANDARD 2' X 4' FLUORESCENT FIXTURE 600 East 96th Street
CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN Suite 100
OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE Indianapolis, IN 46240
PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND Phone: (317) 808-6000
THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK 1381 NEW CEILING MOUNTED EXIT LIGHT W/ DIRECTION INDICATION Fax: (317) 808-6797
WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE DUAL -LITE
ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO
MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR
TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT NEW BUILDING STANDARD 2 X 2 LAY -IN GRID SUSPENSION SYSTEM.
LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING.
B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN -BUILD OF ALL ( EXISTING 4 X 4 GRID
SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT
OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY
CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETTY CONTRACTOR --4-- +
I IL IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW
— —W IN INI EW
AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR TWO WAY SWITCH.
—� CE_ I R o M los Oo0 ROM SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF
I E FFICE6 ICE 7_5LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW T3 THREE-WAY SWITCH.
ONLY.
t 3 C. ALL WALLS GO TO BOTTOM OF CEILING UNLESS NOTED OTHERWISE. SEE NL NIGHTLIGHT LOCATION. CSO
CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION.
Architecture
D. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT Engineering
1 ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH Interiors
M 1 8 CONSTRUCTION. Landscape Architecture
E. CEILING HEIGHT IS 9'-11" A.F.F. UNLESS NOTED OTHERWISE. Land Surveying
w F. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, Corporate Otflce
11�7,RAE LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. Cr_ILING GRID 280 East 96th street, Suite 200
I _ — — — — — — — — F 9 SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS Indianapolis, Indiana 46240
TO NOT SHOW LINE OF DEMOLITION. 317.848.7800
FIC 12 � FAX 317.574.0957 ®Copyright 2001
118 G. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO
lot MATCH EXISTING. G.C. TO VERIFY EXISTING GRID LAYOUT AND CONDITION. o
4,.4V/
- 47-
T I H. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT 01
IL UK
Ou 114 F CE ( LE/ DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS o
I A OF 20R MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE
BR K02 CONSOLIDATED TO A GANG PLATE CONDITION.
fllfl^kj 'y 0 FIC t o CP1 I. RE -USE EXISTING LIGHT FIXTURES WHERE FEASIBLE. (EXISTING
F — ji�1 — FIXTURES ARE NOT SHOWN ON PLAN.) STORE SALVAGED LIGHT FIXTURES
11s 18i 3 DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES o
TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED,
VA
RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION.
K. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS.°
.� o
N
REFLECTED CEILING PLAN NOTES: o 0
cPt PROVIDE 300 CFM NON -SWITCHED EXHAUST FAN FOR 24 HOUR HEAT EXHAUST IN I=N T m °'
TELE/DATA ROOM. ap \ m s
0
tnr oo s
U
REFLECTED CEILING PLAN z
SCALE: 1/8" = 1'-0" Q
J
a
a
a
0
J
C3 a
Z U
GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL/DATA LEGEND:Cc
I I Z
CIO~
1. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE DUPLEX WALL OUTLET. Q
MOUNTED 0 18" AFF UNLESS NOTED OTHERWISE. �/ jr 0 W
2. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. � QUADRAPLEX WALL. OUTLET. W �O Z W
3. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE BUILDING STANDARD. DEDICATED CIRCUIT OUTLET.
INTERVIEW INTERNI( INTERVIEW INTERVIEW; l 4. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL 0 J
ROOM ROOM .ROOM ROOM ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY �GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. Q
OFFICE 1707 toss _.�%�� �to5 104 ,r'� i DESIGN -BUILD AREQUIIREMENTSCWOR P ELECTRICAL
ECTRI A ENGINEER,
OWNER, AND/OR O Z
OFFICE OFFICE OFFICE — t t 1 I ` / r CONFERENCE 0 PHONE/DATA WALL OUTLET (BOX AND PULL STRING). W zo Q
441703 i 5. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL
STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE V TELEPHONE WALL OUTLET (BOX AND PULL STRING). Z J
PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT
UNLESS OTHERWISE INDICATED. pp TENANT PROVIDED POWER POLES. PROVIDE JUNCTION BOX IN CEILING 0
---�L a �I ! (2 CIRCUITS ® 20 AMPS EACH
-i# s I:. t i; 6. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. / Q Z
.) TENANT TO PROVIDE TELEDATA
I{ CORRIDOR CABLING TO EACH WORKSTATION. COORDINATE REQUIREMENTS WITH a Z
108 7. ELECTRICAL CONTRACTOR TO COORDINATE FURNITURE SUPPLIERS BASE SYSTEMS FURNITURE PROVIDER.
POWER/DATA FEED. COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING j
REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP. ELECTRICAL 44 HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY.
{ t I I�00
PP _ STORAGE W
I CONTRACTOR TO HARDWIRE FURN TORE SYSTEM TO BUILDING POWER SOURCE.
- OFFICEi 109 POWER/
COMMUNICATIONS PROVIDE FLOOR MOUNTED POWER COMMUNICATIONS AS TOMBSTONES OR FLUSH 48 HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY.
tt2 MOUNTED.
OFFICE
R
_: I(
= ECEPTION
118 {{ .ri {i 101
S— .. _ D
r( li t :#; U �I f� '{{ �--•�� 1; ve"oi"c
i OPEN i D
ALTERNATE:
W_
- OFFICE ELECTRI ADATA PLAN NOTES:
D DATA
V
114 == ` ROOM D 102 I 1. COVERPLATES TO BE BRUSHED STAINLESS STEEL.
OFFICE 7 EPt PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY W
D
OFFICE 1 tt3 f`' '�`4 POWER REQUIREMENTS WITH TENANT EQUIPMENT. .J
119 t' �_.� 3 EP3 EPI p ! 1LL
EP5 Yy I EPz PROVIDE 2" CONDUIT WITH PULL STRING FROM BUILDING TELEPHONE CLOSET. W
r WOEP4 EP2 I PROVIDE WIRE GROUND (6 AWG) TO BUS BAR W/ 6'-01. COILED LOOP FEED
FROM CEILING.
EP3 NEMA 5-20R (20 AMP) DEDICATED OUTLET.
Cert',
8
NEMA L5 -15R (15 AMP) DEDICATED OUTLET.f.
EP5 COORDINATE PLACEMENT OF ACCESS TO POWER & DATA FOR POWER POLES WITH
AP
SYSTEMS FURNITURE PROVIDER. 1 J
STATE<OF
off
Drawing Number:
ELECTRICAL/DATA PLAN
A202
SCALE: 1/8" = 1'-0" Of Sheets
Duke Job Number:
A/E Job Number:
24199C
U
REALTY W RAT,
600 East 96th Strt
Suite 100
Indianapolis, IN 4624
Phone: (317) 808-600k
Fax: (317) 808-679/
■
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
0
0
1
0
0
W
Z
cn
tzi
1n
Z
0
U
0
o
'> U
O p
N mm
o ii q 3 U
r o ps
STAINED 1 1/2" THK. HARDWOOD GLOVE LEDGE;
J
CHAMFER EDGE AT EXTERIOR FACE
a
PLAS. LAM. FACED 1/4" PLYWD. CONT. BELOW GLOVE
W
0
LEDGE, STAINED WD. TRIM AT EXPOSED EDGES
0
Z
CO)
2 1/2" GROMMET, DOUG MOCKETT, MM4A LINER
10"
CO)
a
z
Q
WITH MM -4 CAP; PROVIDE (4) EQ. SPACED
W
4'-0" MAX.
0
w
CIC
1 1/2" THD. COUNTER W/ EXPOSED SURFACES
!=O
-J
W
D O O R S C H
E D U L
FACED AND EDGED WITH PLASTIC LAMINATE
he
z
Q
W
E
CC
C)
J
COUNTER (RETURN) BEYOND @ ADA HEIGHT
(2'-10" MAX)
\\6'
a
DOOR FRAME HARDWARE REMARKS
CL
0
SIZE
W
� ._.... ..__..._ . _ _..__...
STAINED
=
w
1 5i
oHEAVY
DUTY KV SHELF
__._..._...__....._.__.._..__.___._._.___._.___2•_
_., _ ._ 1 1 /2"x 3/4"
HARDWOOD TRIM; WRAP
Z w
z
J ZO J
m w m
�
o o o
STANDARDS.
cc
PARTITION END &
z co
:
_ = Y w ¢ w
a
0
FINISH EDGE
�
o
o w = ¢ � ~¢
u n n u n
A --KV SHELF BRACKETS 12"
I
D o
1. 4„ II
O Z
101
2 i- w
RECEPTION 2®3'-0 8'-0" EXISTING
Jtna_Uo
L,S,CL,DB EXISTING
FINISH TO REMAIN
DEPTH
�ff�"
STAINED
2X WOOD NAILER
1 1/2"x3/4"
102
TELE/DATA 3'-0" 8'-0" 1 3/4" WOOD D2 HM
L,S
"
° HARDWOOD TRIM; WRAP ;r,
103
CONFERENCE
3'-0" 8'-0" 1 3/4" WOOD D1 HM
PS,S
1
PARTITION END; ALIGN '
104
INTERVIEW
3'-0"
8'-0"
1 3/4"
WOOD
D1
HM
PS,S
1 66 1 1/2 0 HOLE THROUGH 3" W/ BOT. OF HC M
3 4" PLASTIC LAMINATE
/
N 1 11 4" SATIN STAINLESS STL. STANCHION
GLOVE LEDGE
105
INTERVIEW
31-0"
8 -0 "
/ ��
1 3/4"
WOOD
D1
HM
PS,S
(WHITE MELAMINE) 12" DEEP
0 ANGLE BRACKETS; TYP.
106
INTERVIEW
3'-0"
8'-0"
1 3/4"
WOOD
D1
HM
PS,S
SHELVING: (4) ROWS WITH
ABILITY TO ADJUST FROM
N
107
INTERVIEW
3'-0"
8'-0"
1 3 4"
/
WOOD
D1
HM
PS,S
„
24 A.F.F. TO 84 A.F.F.
PROVIDE VINYL WALL
COVERING
108
CORRIDOR
3'-0"
8'-0"
1 3/4"
WOOD
D1
HM
PS,S
0
109
STORAGE
3'-0"
8'-0"
1 3/4"
WOOD
D1
HM
L,S
5/�" STANCHION, FACED AND
BLOCKING AS REQUIRED
EDGED W/ PLASTIC LAMINATE.
111
OFFICE
3'-0"
8'-0"
1 3/4'
WOOD
D1
HM
L,S
SPACE AT MAX. 4'-0" O.C.
El
112
OFFICE
3'-0" 8'-0" 1 3/4" WOOD D1 HM
PS,S
STAINED 1" x 4
113
OFFICE
3'-0" 8'-0" 1 3/4"1 WOOD D1 HM
PS,S
-FINISH
4" VINYL BASE
HARDWOOD BASE
114
OPEN OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM
/
L,S,CL,DB BUILDING STANDARD ON
CORRIDOR SIDE WSt ON TENANT SIDE
SHELVINGRECEPTION
COUNTER
115
OFFICE
3'-0" 8'-0" 1 3/4" WOOD D1 HM
L,S
SEC TI0N
(`-1� SECTION
116
OFFICE
3'-0" 8'-0" 1 3/4" WOOD D1 HM
PS,S
117
OFFICE
3'-0" 8'-0" 1 3/4" WOOD D1 HM
L,S
A601
SCALE: 1/2" = 1'-0"
A601 SCALE: 1 1/2" = 1'-0"
118
OFFICE
3'-0" 8'-0" 1 3/4" WOOD D1 HM
PS,S
119
OFFICE
3'-0" g'-0" 1 3/4" WOOD D1 HM
PS,S
DOOR SCHEDULE NOTES
1 .
ALL DOORS ARE TO BE STAINED WS1 (REFER TO FINISH
LEGEND) EXCEPT
DOOR #101 AND DOOR #114 (REFER TO REMARKS ABOVE.)
2.
PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO
MATCH BUILDING STANDARD.
3.
CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION.
4.
COORDINATE KEYING LOCKSETS WITH TENANT.
Le 2'-3" 2'-6" 2'-3"
2'-0 e
5.
ALL DOOR FRAMES ARE TO BE PAINTED (P2.)
TYPICAL WALL TYPE
PREFINISHED ALUMINUM RECEIVER
/
TIME LAKE BAINBRIDGE UPPER
TRIM "G8350" -FASTEN AT WINDOW
/ \ — — \ / \
CABI S W/(2) ADJUSTABLE
SILL & SET IN A CONTINUOUS BEAD OF
- — _ i _
SHEL ES & 4" CHROME WIRE
ACOUSTICAL SEALANT. TRIM COLOR
C'4 (
PULL .
TO MATCH BLDG. WINDOW MULIONS
\ __ / \ /
PLAS IC LAMINATE COUNTER
_
�-
34" .F.F. WITH 1 1/2" EDGE"
"
\ / 4 \ /
BOWL 1SINK APR ON SS SINGLE
c
TI
�'-off �
TN ��
3'-0"
A601
w
II
PLAST C LAMINATE COUNTER
36" A F.F. WITH 1 1/2" EDGE
& 4" BACKSPLASH. F Pu
ADA COMPLIANT
— —
LEVER HARDWARE
TIMBERLAKE BAINBRIDGE BASE
0
o
/ \ / \
CABIN -TS/DRAWERS W/(1)
00
o / \ o / \
ADJUSTABLE SHELF & 4"
METAL STUD
i = _ _ =
CHRO E WIRE PULLS.
CONTINUOUS BEAD OF
\ / /
/ \ /
PROVI E GROMMET IN CABINETRY.
24" X 24" METAL
ACOUSTICAL SEALANT
\ / \
VERT EXACT LOCATION W/ TENANT
ADA COMPLIANT
LOUVER PANEL
LEVER HARDWARE
TO CONCEAL PLUMBING
TO MATCH CABINETRY
DD=1
WINDOW MULLIONBREAK
ROOM CABINETRY
DOORFRAME
DETAIL
2 ELEVATION
ELEVATIONS
6
A601 SCALE: NTS
A601 SCALE: 1/2" = 1'-0"
SCALE: '1/4" = 1'-0"
1 /2"HW,
1 2
/"
& 11-11/4"V
2 _1.
PLASTIC LAMINATE
COUNTER AT ADA HT
(341 WITH 1 1/2" EDGE,
PLASTIC LAMINATE 12" DEEP
SHELF ON PLASTIC LAMINATE
ANGLED SUPPORTS ® 2'-0"
I3
1/2" APRON, & 6"
AS NECDSSARLOCKY. PNG IN WALL
BACKSPLASH. ADA
I CONNECT TO
I
COMPLIANT SS SINGLE
BUILDING MAINS
I
BOWL SINK WITH ADA
o
COMPLIANT FIXTURES.
N
PLASTIC LAMINATE COUNTER
Pu
36" A.F.F. WITH 1 1/2" EDGE.
SIN!f,,�
F Pl.l
CD-
- - -
- -
TIMBERLAKE BAINBRIDGE BASE -
CABINETS/DRAWERS W/(1)
2
o
ADJUSTABLE SHELF & 4"
REMOVABLE PANEL TO
�, ---- ---- ---- ---- ----
- - -
---- CHROME WIRE PULLS.
1_1
MATCH CABINETRY (TO
"
CONCEAL PLUMBING)
ATTACHED AT ENDS TO
TO BUILDING
ADJACENT CABINETS.
DRAIN
Tj
ATTACHMENTS TO BE
L 4'-0" L 4'-0' �,
4'-0" I,
CONCEALED.
TYPICAL PLUMBING
ADA SINK
WORK COUNTER
5 ISOMETRIC
4 SECTION
r3***), ELEVATION
A601 SCALE: NTS
A601 SCALE: 1" = 1'-0"
A601 SCALE: 1/2" = 1'-0"
U
REALTY W RAT,
600 East 96th Strt
Suite 100
Indianapolis, IN 4624
Phone: (317) 808-600k
Fax: (317) 808-679/
■
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
0
0
1
0
0
W
Z
cn
tzi
1n
Z
0
U
0
o
'> U
O p
N mm
o ii q 3 U
r o ps
Certifi���i.._ 0
AR0091�3&
STATE OF
Drawing Number:
A601
Of Sheets
Duke Job Number:
A/E Job Number:
24199C
Cal
J
a
W
0
0
Z
CO)
CO)
a
z
Q
0
W
O
0
w
CIC
OV)Q
!=O
-J
W
W
3
a
he
z
Q
W
CC
C)
J
a
CL
0
W
00
=
0
cc
0
0
0
Certifi���i.._ 0
AR0091�3&
STATE OF
Drawing Number:
A601
Of Sheets
Duke Job Number:
A/E Job Number:
24199C