Loading...
HomeMy WebLinkAbout04070217 Building PlansARCHITECT: CSO 280 E. 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 Lr..jr� 19171 848.7800 19171 574.0957 FAX CONTRACTOR: VAW Duke CONSTRUCTION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX OF DRAWINGS • COVER • A201 CONSTRUCTION PLAN & FINISH PLAN • A202 REFLECTED CEILING PLAN & ELECTRICAL DATA PLAN • A601 DOOR SCHEDULE - ELEVATIONS DETAILS ArPWM As SUBM ED APPROVED tis MM MEM smm DATE CWMY KEYPLAN SCALE: NOT TO SCALE EIGHT PARKWOOD CROSSING SPECIFICATIONS AND GENERAL NOTES 0 CONTRACT CONDITIONS 0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDMONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION, 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS, 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 0,2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. 0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. 0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. 0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. 0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. 0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 1 GENERAL REQUIREMENTS 1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. 1.2 THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND "FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. 1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. 1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6" X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6" X 6" ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). 1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. 1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. 1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. 1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. ,2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. 1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. 2 DEMOLITION 2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PIANS TO DETERMINE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW WORK. 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO ALLOW SUCH WORK, NO CHANGE ORDER WILL BE ISSUED FOR ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL BE INCLUDED. 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE DRAWINGS. 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEIN FINISHES. 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR NOTED TO BE REPAIRED. 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK IN SCOPE OF CONTRACT. 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH ;S ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE - OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND ARE PROTECTION SYSTEMS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ra A RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET. 2.11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. 5 METAL FABRICATIONS 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICA110 OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS REQUIRED TO COMPLETE WORK. 6 WOOD AND PLASTIC 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE 'CONSTRUCTION GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE CONTENT. 6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32". 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH 'PREMIUM GRADE' AWI STANDARDS. .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR TO FABRICATION OF MULTIPLE UNITS. 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACES. .2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS. 6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4008 FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL. THICKNESS). .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. .3 CABINET HARDWARE SCHEDULE: .1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES" BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; i SP 45 OR SP 46 DR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJEC11ON MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL SUITE 104 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY ELECTRICAL SYSTEMS. OPERATING FOR TEN DAYS. GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A STRAIGHT WITH NO DISTORTIONS. CERTIFIED ENGINEER. 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS WIDTH NOT TO EXCEED 1/8 U.O.N. DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND OUTLETS. OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 7 JOINT SEALERS 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL AND FIXTURES: 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS .1 "DOW CORNING 786"; DOW CORNING CORP. SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR .2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED .3 "863 1345 WHITE"; PECORA CORP. WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. .4 "PROGLAZE WHITE"; TREMCO CORP. EQUIPMENT. .5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND SURFACES: INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL .1 "CHEM -CALK 600'; BOSTIK CONSTRUCTION PRODUCTS DIV. TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE .2 "AC -20"; PECORA CORP. INSTALLATION SHALL OCCUR. 15/16.9 .3 "SONOLAC'; SONNEBORN BUILDING PRODUCTS OUTLETS UNLESS , LES OTHERWISE NOTED. .4 'TREMCO ACRYLIC LATEX 834'; TREMCO, INC. ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD 8 DOORS AND WINDOWS 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. 15/16.13 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO AND LOCKSETS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 GENERAL NOTES GN.1 REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. 9 FINISHES PROCEEDING WITH CONSTRUCTION. 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A. TO FINISHED FACE OF GYPSUM BOARD. .1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS, AT CEILING. USE PREFORMED OUTSIDE CORNERS. 9.2 GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE "X" TAPERED SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND GNA TERMINATE WALLS AT UNDERSIDE OF CEIUNG UNLESS INDICATED JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE OTHERWISE. GN.5 WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH WITH CONSTRUCTION. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA - CONTRACTOR SHALL PROVIDE CHAD( LINES DELINEATING WALL LAYOUT 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND 9.11 DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS FINISHING OF GYPSUM BOARD. OBSERVATION. 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT DAMAGED OR SOILED TILES. FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON- .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED, GN.8 IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL CLOSE -IN OF WALLS, REFLECTED CEILING PLAN SHALL GOVERN. 10 .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 101 UNLESS NOTED OTHERWISE. 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CASED OPENING UNLESS NOTED OTHERWISE. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH CARPET. 9.6 RESILIENT FLOORING: A UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. .2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. 9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM SURFACE VARIATION OF 9' IN 10 FEET, NON -CUMULATIVE. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING STANDARDS: FLAMMABILITY: ASTM 2859 SURFACE BURNING: ASTM E84 SMOKE DENSITY: ASTM E662 SOUND ABSORPTION: ASTM C423 FADE RESISTANCE: AATCC 16E STATIC RESISTANCE: AATCC 134 WARRANTY: 10 YEARS .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. INDIANAPDX.IS, INDIANA PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, REINSTALL SUCH ITEMS. .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT SYSTEMS BASED ON DEVOE TO ESTABLISH OUALITY STANDARD FOR THE VARIOUS SUBSTRATES, AS INDICATED. 1. FERROUS METAL: A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL 2. NON-FERROUS METAL- A. ETALA. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #417+02 METALCLAD ACRYLIC LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC SEMI -GLOSS FINISH 3. FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING 4. NON-FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER REDUCIBLE ACRYLIC DRY FOG COATING. 8. WOOD: A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL B. STAIN -VARNISH RUBBED FINISH: 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN PASTE WOOD FILLER (OPEN GRAIN WOODS). 2. STAIN: 1 COAT 196XX WONDER WOODSTAIN ALKYD STAIN. 3. SEALER: 1 COAT #4900 WONDER WOODSEALER QUICK DRY SEALER. 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN ALKYD SATIN VARNISH, 10. GYPSUM WALLBOARD: A. ACRYLIC LATEX SATIN ENAMEL FINISH: 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX PRIMER -SEALER. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC LATEX SATIN ENAMEL 13, PRECAST CONCRETE: A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC LATEX HOUSE PAINT PRIMER. 2. FINISH: 1 COAT #441101 DEV-VO-TEX LATEX TEXTURE COATING. WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND WITHOUT WRINKLES, GAPS OR OVERLAPS. .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT ACCEPTABLE. .2 SEAMS MUST BE AT LEAST 2' FROM INSIDE CANERS AND 6" FROM OUTSIDE CORNERS. ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO BUILDING STANDARD, PROVIDE JL INDUSTRIES 'AMBASSADOR' SERIES, SEMI RECESSED, DUO -PANEL, FIELD PAINTED. I;wRMEL FIRE DEPARTMENT PLAN REVIEW Received 2'Z wed Released St. Permit0 63 i[y Permit'Lazo w Ufa Reviewed By.- Title: y.Title: CITY OF CARMEL - CLAY TOWNSHIP Dept. of Community Services Building & Code Enforcement One Civic Square - First Floor Carmel, IN 46032 Plan Authentication Certification and Agreement As the authorized agent responsible for obtaining a permit or permits', I certify that these plans ore identical to those released for construction by the Indiana Dept. of Fire d Building Services. I also understand that if it is determined that these plans are not identical, a STOP WORK ORDER will be served, as required and the Ordinances referenced below. )Q AUTHORIZED SIGNATURE DATE ' Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 and 29.4.3 entitled "Administration". Required by Cannel Clay Township Zoning Ordinance, Section 31.1 entitled "Violations and penalties". t s:pertnits/forms/authentication Aug 2001 12 FURNISHINGS 12.1 CASEWORK: .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: .1 IMPERIAL CABINET CO., INC, .2 MERILLAT INDUSTRIES, INC. .3 YORKTOWNE CABINETS 15/16 MECHANICAL AND ELECTRICAL 15/16.1 MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND ELECTRICAL SYSTEMS. 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A CERTIFIED ENGINEER. 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 15/16.4 SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL COORDINATE WITH OTHER CEILING COMPONENTS. 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OWNER'S AGENT, 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED EQUIPMENT. 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE INSTALLATION SHALL OCCUR. 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF OUTLETS UNLESS , LES OTHERWISE NOTED. 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE IVORY. 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL PROVIDING PROPER ACCESS TO RECEPTACLES. 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL FOR SPECIFIC LOCATION. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN" CONSTRUCTION. GN GENERAL NOTES GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: A. TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS, C. TO TOP OF FINISHED FLOORS. D. TO BOTTOM OF FINISHED CEILINGS. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, EXISTING CONSTRUCTION AND WALL TYPES. GNA TERMINATE WALLS AT UNDERSIDE OF CEIUNG UNLESS INDICATED OTHERWISE. GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.6 CONTRACTOR SHALL PROVIDE CHAD( LINES DELINEATING WALL LAYOUT FOR THE ARCHTTECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS OBSERVATION. GN] FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0' NON- CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED, GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS, GN.9 SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. GNAO ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY TENANT. 07/06/04 CSO #24199C CONSTRUCTION PLAN SCALE: 1/80P = 1'-0" II OO O O INTERVIEW INTERVIEW INTERVIEW INTERVIEW C3 P1 C3 P1 ROOM ROOM ROOM ROOM OFFICE C1 OFFICE OFFICE 61 OFFICE Bt — 111 107 106 toy 104 117 116 115 C3 P1 B2OC1 OC182 82SC1 62 CONFERENCE CC3 P1 103 8 61 W1 W1 W1 W1 C1 62 W1 C1 D82ORRIDOR C3 P1 OFFICE B1 118 C3 `P1 OFFICE 81 119 8 (DIS OPEN OFFICE 114 FINISH PLAN SCALE: 1/8" = 1'-0" GENERAL CONSTRUCTION NOTES: CONSTRUCTION PLAN NOTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED FPt ALIGN FINISHED FACES. PATTERN: DENSE PATI. LOOP OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE COLOR: REQ.#912-05030-8 PAINT LOCATION: RECEPTION, CONE, INTERVIEW VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. CARPET — DIRECT GLUE W 0 N MFG: J & J INDUSTRIES Z 0 F FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS. USE SEALANT AT MULLIONS B. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. LOCATION: 12" RECEPTION BORDER FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY CARPET — DIRECT GLUE mm MFG: J & J INDUSTRIES DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 6/A601. C. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION. FP3 PROVIDE l4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED REFRIGERATOR. VERIFY EXACT LOCATION: GENERAL vcT1 VINYL COMPOSITION TILE LOCATION OF ALL APPLIANCES REQUIRING A WATER SOURCE WITH TENANT. D. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. FP4 REFRIGERATOR, VENDING MACHINE, &WATER COOLER PROVIDED AND INSTALLED BY TENANT. G.C. TO C Y o Q LOCATION: BREAK, TELE/DATA, STORAGE PROVIDE POWER SOURCE FOR APPLIANCES. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S E. ALL NEW TRACK AND TRIM AT WALL CEILING CONDITIONS SHALL MATCH EXISTING COLOR AND VINYL BASE —4" COVE BASE MANUAL. MANUFACTURER: JOHNSONITE MATERIAL TO PROVIDE CONTINUOUS/CONSISTENT APPEARANCE THROUGHOUT CEILING. FP5 ENTIRE WALL TO HAVE 3/4" FRT PLYWOOD PHONE BOARD, MOUNTED 20" A.F.F. TO CEILING. PHONE BOARD % F. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE FINISH: (2) COATS STAIN, (2) COATS TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. CLEAR SEMI—GLOSS MOUNTED ITEMS. POLYURETHANE SEALER. PROVIDE 50 r G. EXISTING DOORS AND DOOR FRAMES TO BE REUSED ARE TO BE CLEANED AND REINSTALLED AT FP6 NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" % COMPLETION OF CONSTRUCTION. CONTACT DESIGNER TO REVIEW AND APPROVE DOORS THAT ARE Drawing Number: AFF. PAINT TO MATCH ADJACENT WALL SURFACE. FIRE EXTINGUISHER CABINET TO MATCH BUILDING STANDARD, UNLESS Of Sheets QUESTIONABLE FOR REUSE. A/E Job Number: NOTED OTHERWISE. ' H. ' NEW DOOR AND FRAME NUMBERS CORRESPOND TROOM NUMBERS. WHERE MORE THAN ONE F 77 NEW BASE AND UPPER CABINETS WITH SINGLE BOWL STAINLESS STEEL SINK (TO MEET ADA REQUIREMENTS). CABINETS TO BE TIMBERLAKE BAINBRIDGE. PLASTIC LAMINATE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). A COUNTERTOP TO BE FORMICA FOLKSTONE CELECTA #692-58. = I. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. FP8 COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. J. ALL NEW DOORS SHALL ALLOW 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. FP9 . 3 4" WHITE MELAMINE SHELVES ON HEAVY DUTY KV 187-78" STANDARDS & KV 87-12" WACKETS. K. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT PROVIDE ADDITIONAL BLOCKING AS REQUIRED. REFER TO SECTION 7/A601.12"d WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY P1 RECEPTION LEDGE ON PARTIAL HEIGHT WALL. REFER TO DETAIL 1/A601. PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. P1 PLASTIC LAMINATE WORK COUNTER WITH (3) 48" W. TIMBERLAKE BAINBRIDGE BASE CABINETS BELOW, PLASTIC LAMINATE SHELF ABOVE. REFER TO ELEVATION 3/A601. L. RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH P1 REMOVE SECTION OF EXISTING CORRIDOR WALL TO PROVIDE NEW ENTRY TO SUITE. DESIGNER. M. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL AND AT ALL WALL LEGEND: COUNTERTOPS AND BACKSPLASH JUNCTURES. NOTE: ALL WALLS TO BE W1 UNLESS NOTED OTHERWISE. N. BUILDING OWNER AND/OR G.C. TO PROVIDE MINIBLINDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE RELOCATED ARE TO BE STORED DURING CONSTRUCTION PHASE, THEN = _ = EXISTING CONSTRUCTION TO BE REMOVED CLEANED AND REINSTALL UPON COMPLETION OF CONSTRUCTION. EXISTING PARTITION TO REMAIN 0. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS NEW WALL PARTITION SCHEDULED. NEW LOW WALL PARTITION P. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. W1 — 2-1/2" 25 GAUGE METAL STUDS @24"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. Q. ALL NEW LOCATIONS TO BE KTE DE VERIFIED WITH TENANT IN FIACES DEANDEWITHI/RESP COTMTO�NEWEEL CTRCALTLAYOUT. GROMMET W2 2-1/2" 25 GAUGE METAL STUDS @24"O.C. WITH 5/8" GYPSUM WALL BOARD COLOR TO BE: BLACK. — EACH11n ,J' GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED WS1. B. ALL DOOR FRAMES TO BE PAINTED P2. C. ALL NEW WOOD TRIM TO BE FINISHED WS1. D. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPET IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRE OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH. F. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. G. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. H. BASE IN REST ROOMS MUST BE MINIMUM 5" HEIGHT TO MEET BOARD OF HEALTH CODE. I. PAINT NEW PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT. COLOR TO MATCH ADJACENT WALL FINISH. J. PAINT ALL EXPOSED METAL SURFACES (i.e.. GRILLS, HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE. K. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. L. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK TO DESIGNER FOR REVIEW AND APPROVAL BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. M. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. N. PROVIDE FULL HEIGHT OR PARTIAL HEIGHT, CLEAR OR COLOR CORNER GUARDS. REFER TO FINISH PLAN FOR LOCATIONS. FINISH PLAN NOTES: FN1 NEW BASE AND UPPER CABINETS TO BE TIMBERLAKE BAINBRIDGE. PLASTIC LAMINATE COUNTERTOP TO BE FORMICA FOLKSTONE CELECTA #692-58. &OAK RECEPTION LEDGE ON PARTIAL HEIGHT WALL. PLASTIC LAMINATE WORKSURFACE. REFER TO DETAIL 1/A601. FN3 PLASTIC LAMINATE WORK COUNTER WITH (3) 48" W. TIMBERLAKE BAINBRIDGE BASE CABINETS BELOW, PLASTIC LAMINATE SHELF ABOVE. REFER TO ELEVATION 3/A601. FN4 (4) 12"dp. 3/4" WHITE MELAMINE SHELVES. REFER TO SECTION 7/A601. FN5 MATCH EXISTING CORRIDOR FINISHES IN NEW ENTRY ALCOVE. SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. PROVIDE 2 1/2 N, SOUND INSULATION IN HORIZONTAL SURFACE ABOVE CEILING AND INSIDE WALL, INSULATION TO EXTEND 2'-0" IN BOTH DIRECTIONS FROM CENTER LINE OF WALL. W3 NEW LOW WALL CONSTRUCTION TO BE: 2-1/2" 25 GAUGE METAL STUDS @16"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. REFER TO SECTION 1/A601 FOR EXACT HEIGHT OF LOW WALLS. M W4 2-1/2" 25 GAUGE METAL STUDS @24" O.C. WITH 5/8" GYPSUM WALL BOARD 6 ONE SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. — t --� W5 NEW WALL CONSTRUCTION TO MATCH ADJACENT PARTITION CONSTRUCTION. DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE FINISH LEGEND: FLOORCOVERINGS W1 CARPET — DIRECT GLUE C1 MFG: J & J INDUSTRIES Landscape Architecture PATTERN: DENSE PATI. LOOP Corporate Office COLOR: REQ.#912-05030-8 PAINT LOCATION: RECEPTION, CONE, INTERVIEW GDC2 CARPET — DIRECT GLUE W 0 N MFG: J & J INDUSTRIES Z 0 F PATTERN: DENSE CUT PILE o 0 COLOR: REQ.#912-05030-9 P2 LOCATION: 12" RECEPTION BORDER C3 CARPET — DIRECT GLUE mm MFG: J & J INDUSTRIES O (15 0 PATTERN: DENSE LOOP PLASTIC LAMINATE COLOR: REQ.#912-05030-3 MANUFACTURER: FORMICA LOCATION: GENERAL vcT1 VINYL COMPOSITION TILE FINISH: MATTE MFG: ARMSTRONG wst PATTERN: IMPERIAL TEXTURE � COLOR: #51915 CHARCOAL Y o Q LOCATION: BREAK, TELE/DATA, STORAGE BASE POLYURETHANE SEALER. 61 VINYL BASE —4" COVE BASE O :D 0- W 3�zz MANUFACTURER: JOHNSONITE 0 _ a Z � COLOR: CB -18 NAVY BLUE 62 OAK WOOD BASE — 4" X 1" FINISH: (2) COATS STAIN, (2) COATS z CLEAR SEMI—GLOSS V POLYURETHANE SEALER. PROVIDE 50 FURNITURE GRADE FINISH, STAIN: MINWAX #225 RED MAHOGANY. WALLCOVERING W1 MFG: KOROSEAL VICRETEX Engineering PATTERN: DAKOTA Landscape Architecture COLOR: EAGLE FEATHER DK -21-07 Corporate Office LOCATION: RECEPTION, CONE, INTERVIEW PAINT 0 1 P1 MFG: SHERWIN WILLIAMS W 0 N COLOR: HARMONY #SW1004 PURE WHITE Z 0 F FINISH: EGGSHELL LATEX o 0 LOCATION: GENERAL P2 MFG: SHERWIN WILLIAMS COLOR: #SW1233 ELITE GREY mm FINISH: SEMI—GLOSS ALKYD ENAMEL O (15 0 LOCATION: DOOR FRAMES PLASTIC LAMINATE PL1 MANUFACTURER: FORMICA COLOR: FOLKSTONE CELECTA 692-58 a FINISH: MATTE WOOD FINISH wst OAK WOOD VENEER � FINISH: (2) COATS STAIN, (2) COATS Y o Q CLEAR SEMI—GLOSS W V POLYURETHANE SEALER. o STAIN: MINWAX #225 RED MAHOGANY. NOTE: WHEN ORDERING CARPET, SIDEMARK "ALLEGIS GROUP ACCT." ue REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 w.. u CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 1 a n 0 W 0 N Z 0 F C 0 o 0 CK O O e N mm m O (15 0 N� U c)r z a CL � s z Cal � zZ `� Y o Q z as W V o z o 0 CC �J J d. O :D 0- W 3�zz a ,e Q O 0 _ a Z � a � 0 z O V Ce r U 50 16 ��OQ910Q3fi, j STATf or �y' e ANS' It Drawing Number: A201 Of Sheets Duke Job Number: A/E Job Number: 24199C w.. u GENERAL CEILING NOTES: REFLECTED CEILING LEGEND: U E REALT coRPow►nON A. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD NEW BUILDING STANDARD 2' X 4' FLUORESCENT FIXTURE 600 East 96th Street CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN Suite 100 OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE Indianapolis, IN 46240 PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND Phone: (317) 808-6000 THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK 1381 NEW CEILING MOUNTED EXIT LIGHT W/ DIRECTION INDICATION Fax: (317) 808-6797 WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE DUAL -LITE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT NEW BUILDING STANDARD 2 X 2 LAY -IN GRID SUSPENSION SYSTEM. LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN -BUILD OF ALL ( EXISTING 4 X 4 GRID SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETTY CONTRACTOR --4-- + I IL IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW — —W IN INI EW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR TWO WAY SWITCH. —� CE_ I R o M los Oo0 ROM SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF I E FFICE6 ICE 7_5LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW T3 THREE-WAY SWITCH. ONLY. t 3 C. ALL WALLS GO TO BOTTOM OF CEILING UNLESS NOTED OTHERWISE. SEE NL NIGHTLIGHT LOCATION. CSO CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. Architecture D. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT Engineering 1 ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH Interiors M 1 8 CONSTRUCTION. Landscape Architecture E. CEILING HEIGHT IS 9'-11" A.F.F. UNLESS NOTED OTHERWISE. Land Surveying w F. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, Corporate Otflce 11�7,RAE LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. Cr_ILING GRID 280 East 96th street, Suite 200 I _ — — — — — — — — F 9 SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS Indianapolis, Indiana 46240 TO NOT SHOW LINE OF DEMOLITION. 317.848.7800 FIC 12 � FAX 317.574.0957 ®Copyright 2001 118 G. REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO lot MATCH EXISTING. G.C. TO VERIFY EXISTING GRID LAYOUT AND CONDITION. o 4,.4V/ - 47- T I H. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT 01 IL UK Ou 114 F CE ( LE/ DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS o I A OF 20R MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE BR K02 CONSOLIDATED TO A GANG PLATE CONDITION. fllfl^kj 'y 0 FIC t o CP1 I. RE -USE EXISTING LIGHT FIXTURES WHERE FEASIBLE. (EXISTING F — ji�1 — FIXTURES ARE NOT SHOWN ON PLAN.) STORE SALVAGED LIGHT FIXTURES 11s 18i 3 DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES o TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, VA RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. K. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS.° .� o N REFLECTED CEILING PLAN NOTES: o 0 cPt PROVIDE 300 CFM NON -SWITCHED EXHAUST FAN FOR 24 HOUR HEAT EXHAUST IN I=N T m °' TELE/DATA ROOM. ap \ m s 0 tnr oo s U REFLECTED CEILING PLAN z SCALE: 1/8" = 1'-0" Q J a a a 0 J C3 a Z U GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL/DATA LEGEND:Cc I I Z CIO~ 1. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE DUPLEX WALL OUTLET. Q MOUNTED 0 18" AFF UNLESS NOTED OTHERWISE. �/ jr 0 W 2. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. � QUADRAPLEX WALL. OUTLET. W �O Z W 3. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE BUILDING STANDARD. DEDICATED CIRCUIT OUTLET. INTERVIEW INTERNI( INTERVIEW INTERVIEW; l 4. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL 0 J ROOM ROOM .ROOM ROOM ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY �GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. Q OFFICE 1707 toss _.�%�� �to5 104 ,r'� i DESIGN -BUILD AREQUIIREMENTSCWOR P ELECTRICAL ECTRI A ENGINEER, OWNER, AND/OR O Z OFFICE OFFICE OFFICE — t t 1 I ` / r CONFERENCE 0 PHONE/DATA WALL OUTLET (BOX AND PULL STRING). W zo Q 441703 i 5. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE V TELEPHONE WALL OUTLET (BOX AND PULL STRING). Z J PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. pp TENANT PROVIDED POWER POLES. PROVIDE JUNCTION BOX IN CEILING 0 ---�L a �I ! (2 CIRCUITS ® 20 AMPS EACH -i# s I:. t i; 6. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. / Q Z .) TENANT TO PROVIDE TELEDATA I{ CORRIDOR CABLING TO EACH WORKSTATION. COORDINATE REQUIREMENTS WITH a Z 108 7. ELECTRICAL CONTRACTOR TO COORDINATE FURNITURE SUPPLIERS BASE SYSTEMS FURNITURE PROVIDER. POWER/DATA FEED. COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING j REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP. ELECTRICAL 44 HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. { t I I�00 PP _ STORAGE W I CONTRACTOR TO HARDWIRE FURN TORE SYSTEM TO BUILDING POWER SOURCE. - OFFICEi 109 POWER/ COMMUNICATIONS PROVIDE FLOOR MOUNTED POWER COMMUNICATIONS AS TOMBSTONES OR FLUSH 48 HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. tt2 MOUNTED. OFFICE R _: I( = ECEPTION 118 {{ .ri {i 101 S— .. _ D r( li t :#; U �I f� '{{ �--•�� 1; ve"oi"c i OPEN i D ALTERNATE: W_ - OFFICE ELECTRI ADATA PLAN NOTES: D DATA V 114 == ` ROOM D 102 I 1. COVERPLATES TO BE BRUSHED STAINLESS STEEL. OFFICE 7 EPt PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY W D OFFICE 1 tt3 f`' '�`4 POWER REQUIREMENTS WITH TENANT EQUIPMENT. .J 119 t' �_.� 3 EP3 EPI p ! 1LL EP5 Yy I EPz PROVIDE 2" CONDUIT WITH PULL STRING FROM BUILDING TELEPHONE CLOSET. W r WOEP4 EP2 I PROVIDE WIRE GROUND (6 AWG) TO BUS BAR W/ 6'-01. COILED LOOP FEED FROM CEILING. EP3 NEMA 5-20R (20 AMP) DEDICATED OUTLET. Cert', 8 NEMA L5 -15R (15 AMP) DEDICATED OUTLET.f. EP5 COORDINATE PLACEMENT OF ACCESS TO POWER & DATA FOR POWER POLES WITH AP SYSTEMS FURNITURE PROVIDER. 1 J STATE<OF off Drawing Number: ELECTRICAL/DATA PLAN A202 SCALE: 1/8" = 1'-0" Of Sheets Duke Job Number: A/E Job Number: 24199C U REALTY W RAT, 600 East 96th Strt Suite 100 Indianapolis, IN 4624 Phone: (317) 808-600k Fax: (317) 808-679/ ■ CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 0 1 0 0 W Z cn tzi 1n Z 0 U 0 o '> U O p N mm o ii q 3 U r o ps STAINED 1 1/2" THK. HARDWOOD GLOVE LEDGE; J CHAMFER EDGE AT EXTERIOR FACE a PLAS. LAM. FACED 1/4" PLYWD. CONT. BELOW GLOVE W 0 LEDGE, STAINED WD. TRIM AT EXPOSED EDGES 0 Z CO) 2 1/2" GROMMET, DOUG MOCKETT, MM4A LINER 10" CO) a z Q WITH MM -4 CAP; PROVIDE (4) EQ. SPACED W 4'-0" MAX. 0 w CIC 1 1/2" THD. COUNTER W/ EXPOSED SURFACES !=O -J W D O O R S C H E D U L FACED AND EDGED WITH PLASTIC LAMINATE he z Q W E CC C) J COUNTER (RETURN) BEYOND @ ADA HEIGHT (2'-10" MAX) \\6' a DOOR FRAME HARDWARE REMARKS CL 0 SIZE W � ._.... ..__..._ . _ _..__... STAINED = w 1 5i oHEAVY DUTY KV SHELF __._..._...__....._.__.._..__.___._._.___._.___2•_ _., _ ._ 1 1 /2"x 3/4" HARDWOOD TRIM; WRAP Z w z J ZO J m w m � o o o STANDARDS. cc PARTITION END & z co : _ = Y w ¢ w a 0 FINISH EDGE � o o w = ¢ � ~¢ u n n u n A --KV SHELF BRACKETS 12" I D o 1. 4„ II O Z 101 2 i- w RECEPTION 2®3'-0 8'-0" EXISTING Jtna_Uo L,S,CL,DB EXISTING FINISH TO REMAIN DEPTH �ff�" STAINED 2X WOOD NAILER 1 1/2"x3/4" 102 TELE/DATA 3'-0" 8'-0" 1 3/4" WOOD D2 HM L,S " ° HARDWOOD TRIM; WRAP ;r, 103 CONFERENCE 3'-0" 8'-0" 1 3/4" WOOD D1 HM PS,S 1 PARTITION END; ALIGN ' 104 INTERVIEW 3'-0" 8'-0" 1 3/4" WOOD D1 HM PS,S 1 66 1 1/2 0 HOLE THROUGH 3" W/ BOT. OF HC M 3 4" PLASTIC LAMINATE / N 1 11 4" SATIN STAINLESS STL. STANCHION GLOVE LEDGE 105 INTERVIEW 31-0" 8 -0 " / �� 1 3/4" WOOD D1 HM PS,S (WHITE MELAMINE) 12" DEEP 0 ANGLE BRACKETS; TYP. 106 INTERVIEW 3'-0" 8'-0" 1 3/4" WOOD D1 HM PS,S SHELVING: (4) ROWS WITH ABILITY TO ADJUST FROM N 107 INTERVIEW 3'-0" 8'-0" 1 3 4" / WOOD D1 HM PS,S „ 24 A.F.F. TO 84 A.F.F. PROVIDE VINYL WALL COVERING 108 CORRIDOR 3'-0" 8'-0" 1 3/4" WOOD D1 HM PS,S 0 109 STORAGE 3'-0" 8'-0" 1 3/4" WOOD D1 HM L,S 5/�" STANCHION, FACED AND BLOCKING AS REQUIRED EDGED W/ PLASTIC LAMINATE. 111 OFFICE 3'-0" 8'-0" 1 3/4' WOOD D1 HM L,S SPACE AT MAX. 4'-0" O.C. El 112 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM PS,S STAINED 1" x 4 113 OFFICE 3'-0" 8'-0" 1 3/4"1 WOOD D1 HM PS,S -FINISH 4" VINYL BASE HARDWOOD BASE 114 OPEN OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM / L,S,CL,DB BUILDING STANDARD ON CORRIDOR SIDE WSt ON TENANT SIDE SHELVINGRECEPTION COUNTER 115 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM L,S SEC TI0N (`-1� SECTION 116 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM PS,S 117 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM L,S A601 SCALE: 1/2" = 1'-0" A601 SCALE: 1 1/2" = 1'-0" 118 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM PS,S 119 OFFICE 3'-0" g'-0" 1 3/4" WOOD D1 HM PS,S DOOR SCHEDULE NOTES 1 . ALL DOORS ARE TO BE STAINED WS1 (REFER TO FINISH LEGEND) EXCEPT DOOR #101 AND DOOR #114 (REFER TO REMARKS ABOVE.) 2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. COORDINATE KEYING LOCKSETS WITH TENANT. Le 2'-3" 2'-6" 2'-3" 2'-0 e 5. ALL DOOR FRAMES ARE TO BE PAINTED (P2.) TYPICAL WALL TYPE PREFINISHED ALUMINUM RECEIVER / TIME LAKE BAINBRIDGE UPPER TRIM "G8350" -FASTEN AT WINDOW / \ — — \ / \ CABI S W/(2) ADJUSTABLE SILL & SET IN A CONTINUOUS BEAD OF - — _ i _ SHEL ES & 4" CHROME WIRE ACOUSTICAL SEALANT. TRIM COLOR C'4 ( PULL . TO MATCH BLDG. WINDOW MULIONS \ __ / \ / PLAS IC LAMINATE COUNTER _ �- 34" .F.F. WITH 1 1/2" EDGE" " \ / 4 \ / BOWL 1SINK APR ON SS SINGLE c TI �'-off � TN �� 3'-0" A601 w II PLAST C LAMINATE COUNTER 36" A F.F. WITH 1 1/2" EDGE & 4" BACKSPLASH. F Pu ADA COMPLIANT — — LEVER HARDWARE TIMBERLAKE BAINBRIDGE BASE 0 o / \ / \ CABIN -­TS/DRAWERS W/(1) 00 o / \ o / \ ADJUSTABLE SHELF & 4" METAL STUD i = _ _ = CHRO E WIRE PULLS. CONTINUOUS BEAD OF \ / / / \ / PROVI E GROMMET IN CABINETRY. 24" X 24" METAL ACOUSTICAL SEALANT \ / \ VERT EXACT LOCATION W/ TENANT ADA COMPLIANT LOUVER PANEL LEVER HARDWARE TO CONCEAL PLUMBING TO MATCH CABINETRY DD=1 WINDOW MULLIONBREAK ROOM CABINETRY DOORFRAME DETAIL 2 ELEVATION ELEVATIONS 6 A601 SCALE: NTS A601 SCALE: 1/2" = 1'-0" SCALE: '1/4" = 1'-0" 1 /2"HW, 1 2 /" & 11-11/4"V 2 _1. PLASTIC LAMINATE COUNTER AT ADA HT (341 WITH 1 1/2" EDGE, PLASTIC LAMINATE 12" DEEP SHELF ON PLASTIC LAMINATE ANGLED SUPPORTS ® 2'-0" I3 1/2" APRON, & 6" AS NECDSSARLOCKY. PNG IN WALL BACKSPLASH. ADA I CONNECT TO I COMPLIANT SS SINGLE BUILDING MAINS I BOWL SINK WITH ADA o COMPLIANT FIXTURES. N PLASTIC LAMINATE COUNTER Pu 36" A.F.F. WITH 1 1/2" EDGE. SIN!f,,� F Pl.l CD- - - - - - TIMBERLAKE BAINBRIDGE BASE - CABINETS/DRAWERS W/(1) 2 o ADJUSTABLE SHELF & 4" REMOVABLE PANEL TO �, ---- ---- ---- ---- ---- - - - ---- CHROME WIRE PULLS. 1_1 MATCH CABINETRY (TO " CONCEAL PLUMBING) ATTACHED AT ENDS TO TO BUILDING ADJACENT CABINETS. DRAIN Tj ATTACHMENTS TO BE L 4'-0" L 4'-0' �, 4'-0" I, CONCEALED. TYPICAL PLUMBING ADA SINK WORK COUNTER 5 ISOMETRIC 4 SECTION r3***), ELEVATION A601 SCALE: NTS A601 SCALE: 1" = 1'-0" A601 SCALE: 1/2" = 1'-0" U REALTY W RAT, 600 East 96th Strt Suite 100 Indianapolis, IN 4624 Phone: (317) 808-600k Fax: (317) 808-679/ ■ CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 0 1 0 0 W Z cn tzi 1n Z 0 U 0 o '> U O p N mm o ii q 3 U r o ps Certifi���i.._ 0 AR0091�3& STATE OF Drawing Number: A601 Of Sheets Duke Job Number: A/E Job Number: 24199C Cal J a W 0 0 Z CO) CO) a z Q 0 W O 0 w CIC OV)Q !=O -J W W 3 a he z Q W CC C) J a CL 0 W 00 = 0 cc 0 0 0 Certifi���i.._ 0 AR0091�3& STATE OF Drawing Number: A601 Of Sheets Duke Job Number: A/E Job Number: 24199C