HomeMy WebLinkAbout04070278 Building PlansDOOR SCHEDULE NOTE: G.C. SHALL VERIFY ALL DOOR AND FRAME RATINGS AS REQUIRED BY CODE AND PROVIDE IF NOT EXISTING OR SPECIFIED. REFER ALSO TO THE SPECIFICATIONS. EXIT DOORS TO BE OPERABLE FROM INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. DOOR #01: ENTRANCE DOORS. _ (REFER TO #1/A5.2 & SPECIFICATIONS) (1 PAIR) , fl , 3'-0'1 {6 -0 PAIR) x 9 -0 x 1-3/4 � 5 .. ,ANODIZED ALUM. DOORS &FRAME W/ CLEAR FINISH. KAWNEER 3 0 DOORS. REFER TO SPECIFICATIONS #8410 ALUMINUM ENTRANCES FOR ADDITIONAL INFORMATION REQUIRED. PROVIDE SUBMITTAL FOR ARCHITECT'S REVIEW. ADDITIONAL HARDWARE AS LISTED: (2) STOP HAGER #241 F, 26D FINISH, OR EQ. (2) PULL CO -9 PULL BY KAWNEER, FINISH TO MATCH DOORS. (2) PUSH CP -1 1 PUSH BAR BY KAWNEER, FINISH TO MATCH DOOR. SIGNAGE "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS", PROFESSIONAL CLEANING CONTRASTING, 1 " H. AVANT GARDE BOLD TYPEFACE. NOTE: EXIT DOORS TO BE OPERABLE FROM INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT X DOOR #02: DRESSING ROOM. X X DOOR TYPE 'C'. (REFER TO #3/A1.1) 3'-0" x 6'-8" x 1-3/4" S.C. WOOD DOOR (MAPLE W/CLEAR SATIN FINISH), H.M. FRAME. FRAME PTD. TO MATCH ADJACENT WALL (SATIN FINISH ENAMEL). PROVIDE HARDWARE AS LISTED: 1-1 /2 PAIR BUTTS 4-1/2" x 4-1/2" BALL BEARING HINGES (1) LOCKSET SCHLAGE #D50PD-ATH-626 (LEVER HANDLES), OR EQ. (1) STOP HAGER #241 F, 26D FINISH, OR EQ. (3) SILENCERS BLACK (1) CLOSER NORTON #8301 -AL, OR EQ. (2) KICK PLATES 24" H. x WIDTH OF DOOR, 18 GA. BRUSHED ALUMINUM SIGNAGE "FITTING ROOM", BLACK, 2" H. AVANT GARDE BOLD TYPEFACE. MIRROR 1/4" MIRROR IN 1-1 /2" X 3/4" WD. FRAME (21 " W. x 5'-4" H.) CENTER ON BACK OF DOOR @ 12" A.F.F. DOOR #03 #04, #05, #06, #07: STOCKROOM DOOR. DOOR TYPE 'B'. (REFER TO #2/Al .1) 3'-0" x 6'-8" x 1-3/4" H.M. DOOR, H.M. FRAME, BOTH PTD. TO MATCH ADJACENT WAL (SATIN FINISH ENAMEL). PROVIDE HARDWARE AS LISTED: 1-1 /2 PAIR BUTTS 4-1/2" x 4-1/2" BALL BEARING HINGES (1) STOP HAGER @241 F, 26D FINISH, OR EQ. (3) SILENCERS BLACK (1) CLOSER NORTON #8301 -AL, OR EQ. (1) DOOR HOLDER HAGER #271 D, FINISH, OR EQ. (HEAVY DUTY) (1) PULL PLATE HAGER 30 SERIES, 3" x 12" PLATE W/#6N CAST PULL, 26D FINISH, OR EQ. (2.) ARMOR PLATES BOTH SIDES, 48" H. x WIDTH OF DOOR, 18 G.A. BRUSHED ALUM. SIGNAGE "STAFF ONLY", WHITE, 2" H. AVANT GARDE BOLD TYPEFACE. THRESHOLD SEE FINISH FLOOR PLAN DOOR #08: OFFICE DOOR. DOOR TYPE 'A'. (REFER TO#1 /A1.1) 3'-0" x 6'-8" x 1-3/4" H.M. DOOR, H.M. FRAME, BOTH PTD. TO MATCH ADJACENT WALL. PAINT PT -2 (WHITE, SATIN FINISH ENAMEL) ON INSIDE OF ROOM. PROVIDE HARDWARE AS LISTED: 1-112 PAIR BUTTS 4-1/2" x 4-1/2" BALL BEARING HINGES (1) LOCKSET SCHLAGE #D80PD-ATH-626 (LEVER HANDLES), OR EQ. (1) STOP HAGER #241 F, 26D FINISH, OR EQ. (3) SILENCERS WHITE (1) CLOSER NORTON #8301 -AL, OR EQ. (2) KICK PLATES 24" H. x WIDTH OF DOOR, 18 GA. BRUSHED ALUMINUM NO SIGNAGE REQ'D. X DOOR #09 #10: TOILET ROOM DOOR. DOOR TYPE 'C'. (REFER TO #3/A1.1) 3'-0" x 6'-8" x 1-3/4" H.M. DOOR, H.M. FRAME, BOTH PTD. TO MATCH ADJACENT WALL PAINT PT -2 (WHITE, SATIN FINISH ENAMEL) ON INSIDE OF ROOM. PROVIDE HARDWARE AS LISTED: 1-1/2 PAIR BUTTS 4-1/2" x 4-1/2" BALL BEARING HINGES (1) LOCKSET SCHLAGE #D80PD-ATH-626 (LEVER HANDLES), OR EQ. (1) STOP HAGER #241 F, 26D FINISH, OR EQ. (3) SILENCERS WHITE (1) CLOSER NORTON #8301 -AL, OR EQ. (2) KICK PLATES 24" H. x WIDTH OF DOOR, 18 GA. BRUSHED ALUMINUM SIGNAGE "TOILET", VINYL, BLACK 2" H. AVANT GARDE BOLD TYPEFACE PROVIDE A.D.A. COMPLIANT SIGNAGE AS REQ'D, THRESHOLD SEE FINISH FLOOR PLAN DOOR #11: CORRIDOR/ EXIT DOOR. DOOR TYPE 'C'. (REFER TO #3/A1 .1) 3'-0" x 6'-8" x 1-3/4" H.M. DOOR (1 -HR. RATED), H.M. FRAME, BOTH PTD. TO MATCH ADJACENT WALL (SATIN FINISH ENAMEL), DOOR, FRAME & HARDWARE SHALL BE FOR 1 -HR. RATED CONSTRUCTION AND BEAR AN APPROVED LABEL. PROVIDE HARDWARE AS LISTED: 1-1/2 PAIR BUTTS 4-1/2" x 4-1/2" BALL BEARING HINGES (NONREMOVABLE PINS) (1) PROTEX ALARM LOCK COVER SET FOR 'CONTINUOUS ALARM' LOCK CYLINDERS X (3) SILENCERS WHITE (2) KICK PLATES 2411 H. x WIDTH OF DOOR, 18 GA. BRUSHED ALUMINUM (1) CLOSER NORTON #8301 -AL, OR EQ. (1) DOOR HOLDER HAGER #271 D, FINISH, OR EQ. (HEAVY DUTY) (1) STOP HAGER #241 F, 32D FINISH, OR EQ. SIGNAGE ON INTERIOR: "EXIT", VINYL, BLACK 2" H. AVANT GARDE BOLD TYPEFACE THRESHOLD AS REQ'D FOR 1 -HR. RATED CONSTRUCTION. PEEPHOLE DOOR #12: EXIT/SERVICE ENTRY DOOR. LANDLORD TO PROVIDE SERVICE/ ENTRY DOOR AT TENANT'S EXPENSE. SERVICE DOOR SHALL BE INSULATED 3'-0" x 6'-8" x 1-3/4 H.M. DOOR RATED) W/ FROST PROOF SLAB. INSTALLMETAL CORNER GUARDS AT THE INTERIOR -SIDE JAMBS OF SERVICE DOOR. PAINT TO MATCH ADJACENT WALL (SATIN FINISH ENAMEL). DOOR, FRAME & HARDWARE SHALL BE FOR 1 -HR. RATED CONSTRUCTION AND BEAR AN APPROVED LABEL. PROVIDE HARDWARE AS LISTED, IF NOT EXISTING: 1-112 PAIR BUTTS 4-1/2" x 4-1/2" BALL BEARING HINGES (NONREMOVABLE PINS) (1) PROTEX ALARM LOCK COVER SET FOR 'CONTINUOUS ALARM' LOCK CYLINDERS WALL BASE (3) SILENCERS WHITE (2) KICK PLATES 24" H. x WIDTH OF DOOR, 18 GA. BRUSHED ALUMINUM (1) CLOSER NORTON #8301 -AL, OR EQ. (1) DOOR HOLDER HAGER #271 D, FINISH, OR EQ. (HEAVY DUTY) (1) STOP HAGER #241 F, 32D FINISH, OR EQ. SIGNAGE ON EXTERIOR: "FINISH LINE, SPACE #B16, PER LANDLORD'S CRITERIA X ON INTERIOR: "EXIT", VINYL, BLACK 2" H. AVANT GARDE BOLD TYPEFACE THRESHOLD AS REQ'D FOR EXTERIOR, 1 -HR. RATED CONSTRUCTION. PEEPHOLE 2" 2" t N :�_ F_ CP �o 1 DOOR 'Al SCALE: 1 /4" = 1 '-0" 2" 2" N 2 DOOR ' B' SCALE: 1/4" = 1 `-0" CP o �O 3 DOOR 'C' SCALE: 1/4"= 1'-0" FINISH KEY ALL INTERIOR FINISHES SHALL BE CLASS C, FLAME -SPREAD, 76-200. BUIDING IS FULLY SPRINKLERED. EDBLACK COVE VINYL WALL BASE. 4" HIGH 4" H., #4CR-701 BY BURKE MERCER PRODUCTS CO. INC. 6" H. #BCR -BLACK COVE VINYL WALL E3ASE. 6" HIG CED H K MERCER PRODUCTS CO. INC. 7OI BY B 4 MAPLE WALL BASE, 2" HIGIj 2" H., TYPE "C," NATURAL MAPLE TRANSITION STRIP, WITH UV FINISH BY GAMMAPAR. DARK GRAY GLUE DOWN COMMERCIAL GRADE CARPET CPT 9 CUBIC, PATTERN: 1380102500, COLOR: 4287 SHAPE, BY INTERFACE CARPET. MODULAR, 50 CM X 50 CM GLASBAC TILE. (CARPET PASSES CLASS 1) LANDLORD TILE CT 1 MATCH EXISTING MALL TILE AND GROUT. WHITE PORCELAIN TILE CT 3 12" x 12" (NOM.), *R-290 ROCKWELL WHITE, SEMI -MATTE FINISH, GRANITI REALI / GEOLOGICA COLLECTION BY GRANITI FIANDRE. GRAY PORCELAIN TILE CT 4 12" x 12" (NOM.), #R-190 BIANCO MONTORFANO, SEMI -MATTE FINISH, GRANITI REALI / GEOLOGICA COLLECTION BY GRANITI FIANDRE. CT -6 SOLID BLACK PORCELAIN TILE 12" x 12" (NOM.), #R-200 BLACK GALA, SEMI -MATTE FINISH, GRANITI REALI / GEOLOGICA COLLECTION BY GRANITI FIANDRE. GH) TEXTURED GRAY PORCELAIN TILE 16" x 16" (NOM.),AND CUTTILE TO 12" X 12" (NOM) #ATP78 PIETRA DI LUSERNA, TEXTURED, GEOLOGICA STONE, PIETRA COLLECTION, BY GRANITI FIANDRE PT 1 BLACK PAINT LATEX EGGSHELL FINISH. BENJAMIN MOORE 'READY -MIX BLACK', (REGAL AQUAVELVET FINISH) OR EQ. OVER 'ORANGE PEEL' SPRAYED G.B. FINISH. USE SATIN FINISH ENAMEL ON MTL. SURFACES. PT 2 WHITE PAINT LATEX EGGSHELL FINISH. BENJAMIN MOORE 'READY -MIX WHITE,' (REGAL AQUAVELVET FINISH) OR EQ. USE SATIN FINISH ENAMEL ON MTL. SURFACES. p(-3 BLUE PAINT LATEX EGGSHELL FINISH. BENJAMIN MOORE #791, (REGAL AQUAVELVET FINISH) OR EQ. USE SATIN FINISH ENAMEL ON MTL. SURFACES. PT 4 ZOLATONE PAINT ZOLATONE #ZN-00073J WATER BASE FINISH. APPLICATOR SHALL BE CERTIFIED BY MANUFACTURER. (CLASS "A" FIRE RATED, PERMEABILITY: 5.2 PERMS TO MEET ASTM D-1653) PT 5 RED PAINT LATEX EGGSHELL FINISH. BENJAMIN MOORE #1315, (REGAL AQUAVELVET FINISH) OR EQ. USE SATIN FINISH ENAMEL ON MTL. SURFACES. R 1 BLACK RUBBER FLOORING 4 mm (5/32") THICK, COLOR: #601, MR. SLATE, BY ECO SURFACES. CONTACT: S.R. ZIMMERMAN 717.299.5035. INSTALL PER MANUFACTURER'S INSTRUCTIONS. R 2 GRAY RUBBER FLOORING 4 mm (5/32") THICK, COLOR: #808, GRAVELROCK, BY ECO SURFACES. CONTACT: S.R. ZIMMERMAN 717.299.5035. INSTALL PER MANUFACTURER'S INSTRUCTIONS. R 3 BLUE RUBBER FLOORING 4 mm (5/32") THICK, COLOR: #452, PATTERN #1800 BLUE, BY ECO SURFACES, CONTACT: S.R. ZIMMERMAN 717.299.5035. INSTALL PER MANUFACTURER'S INSTRUCTIONS. R-4 BLUE/GRAY RUBBER FLOORING 4 mm (5/32") THICK, CUS710M COLOR: #3650, BLUE/GRAY, BY ECO SURFACES. CONTACT: S.R. ZIMMERMAN 717.299.5035. INSTALL PER MANUFACTURER'S INSTRUCTIONS. VCT 1 LIGHT GRAY VINYL COMPOSITION TILE 12" x 12" x 1/8" (NOM.), "CHOICES" STANDARD GRADE, #CH -12 STONE WHITE, BY CONGOLEUM, OR APPROVED EQUAL. INSTALL PER MANUFACTURER'S INSTRUCTIONS. (CLASS 1) VyP-1 MAPLE WOOD FLOORING 3/8" x 2 2/3" x RANDOM LENGTH TONGUE & GROOVE, MICRO BEVEL EDGES, 5 -PLY LAMINATED ACRYLIC IMPREGNATED FACTORY FINISHED WOOD FLOORING, NATURAL MAPLE, WITH UV FINISH BY GAMMAPAR, (JEFFERSON COLLECTION, TYPE 2). INSTALLED GLUED DOWN IN STRICT ACCORDANCE WITH INSTALLATION INSTRUCTIONS AS SET FORTH BY GAMMAPAR. (NO LESS THAN CLASS B FLAME SPREAD RATING & PASSES CLASS I RATING FOR CRITICAL RADIANT FLUX.) NOTES: • ALL G.B. WALLS IN SALES AREA SHALL BE PTC. PT -1 (BLACK), U.N.O. • ALL (E) STL. COLUMNS 114 SALES AREA SHALL BE PTD. PT -1 (BLACK - SATIN ENAMEL FINISH) TO DECK. • ALL G.B. WALLS AND CCLUMNS IN STOCKROOM SHALL BE PTD. PT -2 (WHITE) TO 12'-0" A.F.F., U.N.O. • ALL G.B. WALLS & CEILINGS IN DRESSING RM., TOILET RMS., JANITOR'S AREA & OFFICE SHALL BE PTD. PT -4 (ZOLATONE), U.N.O. TYP, 5 6 7 8 N f 9 4 JAMB DETAIL SCALE: 3" = 1 '-0" KEYNOTES 1.24" H. x WIDTH OF DOOR, 18 GA. BRUSHED ALUM. KICKPLATE, BOTH SIDES OF DOOR, TYP. 2.24" x 24" CLEAR TEMPERED WIRE GLASS LITE. 3. 10" x 10" CLEAR TEMPERED WIRE GLASS LITE. 4.2" H. VINYL LETTERING IN AVANT GARDE BOLD TYPEFACE CENTERED ON DOOR. SEE DOOR SCHEDULE FOR SPECIFIC SIGNAGE REQUIRED. S. 5/8" TYPE "X" GYP. BD., TYP. 6. CONT. CAULK PAINTED TO MATCH ADJACENT WALL SURFACE, TYP. 7. FIRE -TREATED WD. BLOCKING, TYP. 8. 16 GA. COLD -ROLLED BLACK IRON STEEL HORZ. BRACING ABOVE DOOR FRAME. (MAX. 16" FROM TOP). EXTEND A MIN. OF 24" PAST VERT. FACE OF FRAME TO STABILIZE DOOR ASSEMBLY. 9. H.M. DOOR FRAME, TYP. 10. 48" H. x WIDTH OF DOOR, 18 GA. BRUSHED ALUM. ARMOR PLATE, BOTH SIDES OF DOOR, TYP, RESPONSIBILITY SCHEDULE ROVIDED INSTALLED NOTES: BY: BY: 1: EXISTING 2: AS REQUIREC C: GENERAL GC: GENERAL 3: GC PATCH/REPAIR ONTRACTOR CONTRACTOR : VERIFY IN FIELD TENANT T: TENANT S: SUBMITTAL REQUIRED L: LANDLORD LL: LANDLORD 6: PER TENANT DIRECTIVE 7: RELOCATED 8: GC COORDINATE GC T LL GC T LL 1 1 2- 3 1 4 1 5 6 7 DIVISION 1: GENERAL REQUIREMENTS ALL PERMITS FEES INSPECTIONS X F X INSURANCE X X CERTIFICATE OF OCCUPANCY X X X PROFESSIONAL CLEANING X X RUBBISH REMOVAL X X TEMP. UTILITIES, SITE PHONE X X X TEMP. BARRICADES X X FLOOR LEVELING X X X X X X • SHOE MIRROR X DIVISION 5: METALS X X POST DISPLAY SYSTEM X X X DIVISION 6: WOOD & PLASTICS DASH -WALL SHOE DISPLAY PANELS X X X CASH WRAP X X X FLOOR DISPLAY FIXTURES CUSTOM • TRY -ON SHOE BENCHEi X X X • DISPLAY TABLES, ACCESSORY SLABS X X X • SHOE MIRROR X X X • FULL LENGTH MIRROR N WD. FRAME X X X DIV. 7: THERMAL & MOISTJRE PROTECTION SEALANTS, CAULKING X X X WATERPROOFING MEMBRlNE X X X X X INSULATION X X X X DIVISION 8: DOORS & WINLOWS H.M. DOORS, FRAMES, THIESHOLDS X X X S.C. WOOD DOORS X X X ALL DOOR HARDWARE X X X STOREFRONT GLAZING SY7EM INCL DOORS X X X DIVISION 9: FINISHES GYPSUM BOARD ASSEMBLIES/MTL. STUDS X X X FLOORING • TILE X I X X • WOOD FLOORING X X X • CARPET X X X • V.C.T. X X X • RUBBER X X X • TRANSITION STRIPS X X X WALL BASE X X X PAINTING X X X STOREFRONT COLUMN ENCLOSURES TILE X X X DIVISION 10: SPECIALTIES NEUTRAL PIER X X X SURFACE MTD. AND/OR SUSP S'c.NS • SIGNAGE (INCL. ADA REQUIRED X X X • ELECTRICAL CONNECTIONS X X X • BLOCKING SUPPORT FRAME X X X GRAPHIC PANELS X I X X FIRE EXTINGUISHERS X X X STOCKROOM SHELVING SYSTEM X X X TOILET ACCESSORIES SEE SPECS. X X X BASKETBALL HOOP & NET X X X DIVISION 11: EQUIPMENT FLOOR DISPLAY FIXTURES STANDARD X X X AUDIO SYSTEM X X X CASH REGISTERS/COMPUTER SYSTEM X X X X TELEPHONE SYSTEM X X X X DIVISION 15: MECHANICAL HVAC X X X PLUMBING X X X FIRE PROTECTION X X X DIVISION 16: ELECTRICAL LIGHT FIXTURES X X X ALL ELECTRICAL WORK X X X PARTITION TYPES REFER ALSO TO WALL SECTIONS - SHEET A2.1 Al 3-5/8" 20 GA.✓ITL. STUD FRAMING @ 16" O.C. W/ (1) LAYER 5/8" TYPE 'X' G.B. ON EACH SIDE, G.B. TO S./ STRUCTURE, FIRE TAPE/SE/'_ PER CODE TO PROVIDE 1 HR. RATED CONSTRUCTION. PROVIDE WATER RESISTANT G.B. @ WET LOCATION A2 3-5/8" 20 GAMTL. STUD FRAMING @ 16" O.C. W/(1) YER 5/8" TYPE 'X' G.B. ON EACH SIDE. G.B. TO B./ STRUCTURE. PROVIDE WATR RESISTANT G.B. @ WET LOCATIONS. A3 3-5/8" 20 G) MTL. STUD FRAMING @ 16" O.C. W/(1) LAYER 5/8" TYPE 'X' G.B. ON EACH SIDE, G.B. TO HEIGHT AS NOTED ON DAWINGS. PROVIDE WATER RESISTANT G.B. @ WET LOCATIONS. C 3-5/8" 20 G. MTL. STUD FRAMING @ 16" O.C. W/(1) LAYER 5/8" TYPE 'X' G.B. ON ONE SIDE. G.B. TO B./ STRUCTURE, UNLESS NOfD OTHERWISE. PROVIDE WATER RESISTANT G.B. @ WET LOCATIONS. E (E) MTL STPD PARTITION BY LANDLORD. PROVIDE (1) LAYER 5/8" TYPE 'X' G.B. ON TENANT'S SIDE (IF NOT EXISTING). EXTEND T03/STRUCTURE, FIRE TAPE/SEAL PER CODE TO PROVIDE 1 HR. RATED CONSTRUCTION @ TENANT DEMISING PARTITIONS E2 (E) CMU PARTITION BY LANDLORD. VERIFY THICKNESS AND CONSTRUCTION IN FIELD. r GEr ' "Awl y x l 3 CARME, igwF- nEPAkwTiW1PNT CITY OF CARMEL/CLAY TOWNSHIP PLAN REVIEWDept. of Community Services ._ Building & Code Enforcement One Civic Square I" Moor; Carmel, IN 46032 Received -7/ -k -Reviewed � Z _ IPAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT As the authorized agent responsible for obtaining a permit or permits', I certify that these plans Released- T ? $ � ! are IDENTICAL to those released for construction by the Indiana Depart. of Fire & Building Services. I also understand that if it is detern-ti, .d that these plans are not identical, a STOP W ORDER will be served, as required u r the Ordinances referenced below. St. Permit 3_ ty Per 0 '7� N & MAMM fi Rwiewed By: 4 Authorized6gignature PrintedName F C T S ! N C Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4.2 CAPITAL OF TEXAS HWY x /Ql and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section 330 AUSTIN TX 78704 Tilt; 31.1 entitled "Violations and Penalties". 4 FAX: 5 1 2. 9 7 04 95 S:Pennits/ Forms/ AuthentStickerl1-01 AREA MAP AEL,5, F Sub/ect to t� � �iVSTr �, Viance wig all CLAY TERRACE MALL Of Staff and CARMELIN D OF GQ i FINISH LINE (LEVEL 1 OF 1) MY OF SPACE #B 16 Y T® Y I c�"A4UV 11 Qt[} --a MAN SYNOPSIS CODES AND/OR STANDARDS: • BUILDING CODE: IBC 2000 WITH 2003 INDIANA AMENDMENTS • MECHANICAL CODE: IMC 2000 WITH 2003 INDIANA AMENDMENTS • ELECTRIC CODE: NEC 2000 WITH 2002 INDIANA AMENDMENTS • PLUMBING CODE: UPC 1997 WITH 1999 INDIANA AMENDMENTS • ENERGY CODE: CABO MODEL ENERGY 1992 W/ 1992 INDIANA AMENDMENTS & GENERAL ADMIN. RULES OF 2001 • ACCESSIBILITY: INDIANA ACCESSIBILITY CHAPTER 11 • GUIDE OF THE AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR CONDITIONING ENGINEERS (ASHRAE) • UNDERWRITERS LABORATORIES • LANDLORD'S FIRE INSURANCE UNDERWRITER • APPLICABLE GOVT AGENCIES, INCL. BUT NOT LIMITED TO OSHA, EPA, ETC. • APPLICABLE STATE AND CITY BUILDING CODES & THE REQUIREMENTS OF ALL PUBLIC UTILITY COMPANIES SERVING THE SHOPPING CENTER. OCCUPANCY CLASSIFICATION: GROUP M - MERCANTILE ,L. FLOOR AREA: SALES/RETAIL AREA: 3,296 SQ. FT. STOCKROOM AREA (INCL. OFFICE, TOILET RMS, ETC.): 1,598 SQ. FT. T ... EXIT CORRIDOR AREA 110 SO. FT. TOTAL GROSS FLOOR AREA: 5,004 SQ. FT.., OCCUPANT LOADS: SALES AREA 3,296 S.F. _ 30 S.F./OCCUPANT =1 10 OCCUPANTS STOCKROOM AREA: 1,598 S.F. _ 300 S.F./OCCUPANT = 6 OCCUPANTS TOTAL OCCUPANTS: 116 OCCUPANTS 1 EXITS: WIDTH OF EXITS: 116 OCCUPANTS x 0.15"/OCCUPANT = 18" EXIT WIDTH REQUIRED / 102" PROVIDED 68" @ MALL ENTRANCE 34" @ ADDITIONAL EXT NUMBER OF EXITS: 2 EXITS REQUIRED AND 2 PROVIDED. MAX. TRAVEL DISTANCE TO EXIT ALLOWED 250 FT. (ACTUAL 140 FT.) i ABBREVIATIONS`ry IF ADJ. ADJUSTABLE F. E. FIRE EXTINGUISHER PT. PAINT A.F.F. ABOVE FINISH FLOOR F. F. FINISH FLOOR PTD. PAINTED ` A.T. ACOUSTICAL TILE FL. FLOOR R RADIUS B/ BOTTOM OF F. T. FIRE TREATED REF. PT. REFERENCE POINT B. B. BALL BEARING GA. GAUGE REQ'D. REQUIRED BLK. BLACK G.B. GYPSUM BOARD REV. REVISION C.J. CONTROL JOINT G.C. GENERAL S.C. SOLID CORE CLG. CEILING CONTRACTOR S.E. SELF EDGED CLR. CLEAR GL. GLASS SIM. SIMILAR CONC. CONCRETE H. HIGH S.S. STAINLESS STEEL CONSTR. CONSTRUCTION H.M. HOLLOW METAL STD. STANDARD CONT. CONTINUOUS HT. HEIGHT ik T/ TOP OF CONTR. CONTRACTOR JT. JOINT TEMP. TEMPERED CPT. CARPET L. LENGTH TYP. TYPICAL CT CERAMIC TILE L.L. LANDLORD U.N.O. UNLESS NOTED O(DIAM.) DIAMETER MAX. MAXIMUM OTHERWISE D. DEEP MIN. MINIMUM V. F. VERIFY IN FIELD D.F. DRINKING FOUNTAIN MTD. MOUNTED VCT VINYL COMPOSITION DIM. DIMENSION MTL. METAL TILE (E) EXISTING MWK. MILLWORK W. WIDE E.J. EXPANSION JOINT O.C. ON CENTER '' W/ WITH ELEV. ELEVATION 0. H. OVERHEAD, OPPOSITE HAND W/OUT WITHOUT EQ. EQUAL OPN'G. OPENING WD. WOOD EXT. EXTERIOR P.O.S. POINT OF SALE WF WOOD FLOORING (CASH REGISTER) SET INDEX A1.1 COVER SHEET E1 ELECTRICAL SYMBOLS, SCHEDULES & RISERS A1.2 SPECIFICATIONS E2 ELECTRICAL LIGHTING PLAN & POWER PLAN A1.3 SPECIFICATIONS E3 PANEL SCHEDULES & PARTIAL PLAN A2.1 FLOOR PLAN E4 ELECTRICAL SPECIFICATIONS A2.2 FINISH FLOOR PLAN Mi MECHANICAL HVAC PLAN & NOTES A3.1 REFLECTED CEILING PLAN M2 PLUMBING PLAN, RISERS, DETAILS & NOTES A4.1 INTERIOR ELEVATIONS M3 MECHANICAL SCHEDULES, DETAILS & NOTES A5.1 STOREFRONT PLAN & REFLECTED CEILING PLAN M4 MECHANICAL SPECIFICATIONS A5.2 STOREFRONT ELEVATIONS & DETAILS A5.3 STOREFRONT SECTIONS & DETAILS MEP -1 LANDLORD'S MECHANICAL CRITERIA A6.1 DETAILS MEP -2 LANDLORD'S ELECTRICAL/PLUMBING CRITERIA SYMBOLS 12'-6" A.F.F. ELEVATION HEIGHT B/G.B. CLG. v Q REVISION 13 P O KEYNOTE pT_2 FINISH KEY (DWG. #) 1 (SHEET #) 4 1 ELEVATION SYMBOL (DWG. #) 1 (SHEET #) 5 SECTION (DWG. #) �A� (SHEET #)r-,,' �, j DETAIL CENTERLINE A PARTITION TYPE #01 DOOR NUMBER LANDLORD INFORMATION LANDLORD: SIMON PROPERTY GROUP 1 1 5 WEST WASHINGTON STREET INDIANAPOLIS, IN 46204 TENANT COORDINATOR: JANE MILLER 317.263.7645, PHONE 317.685.7269, FAX MALL ADDRESS: CLAY TERRACE MALL 14511 CLAY TERRACE BOULEVARD CARMEL, IN JUL 12 2004 .......... N� J"`�. Q�GISTER AR1 7 .' STATE 4F All drawings, specifications, and designs Ccs Mann & Mann Architects, Inc. 2004 06.30.04 DATE PERMIT, L.L. REVIEW, BID ISSUED FOR W • Finis 9 CLAY TERRACE CARMEL, IN SPACE #B 16 COVER SHEET M&MA #4084 FINL STORE A1*1#708 k1 I 51 E I 3 I SECTION SCALE: 3/4" = 1'-0" 9'-4" A. F. F., V.I.F. B/METAL CANOPY 2 1 SECTION 1 1 SECTION SCALE: 3/4" = 1'-0" SCALE: 314" = 1'-0" MANN &MAMM A R C H I T E C T S I N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.799.4 FAX: 512.972.7995 JUL 1 22004 .... ...... "My AR1900 1 vel • ST T1 OF 4 '9cli I TIE0 Ill" tilt 0", All drawings, specifications, and designs Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR 9 Finish ine mnvw.ffh1eh11ne.com CLAY TERRACE CARMEL, /N SPACE #B 16 STOREFRONT SECTIONS M&MA #4084 FINL STORE #708 A593 3 SURFACE MTD. 93 PAPER TOWEL DISP. 24" 27 SURFACE MTD. LONG TILTING MIRROR 2'-0" FRP PANEL, TYP. o \� ALIGN M CENTERS 47 ch — O N N MOP SINK Z Z�-611 MAX B 2 1'-5" -MIN. M a N TOILET ROOM NOTE: INSULATE EXPOSED PIPING UNDER 16 ELEVATIONS SINK PER CODE. DASHED LINE INDICATES KNEE CLEARANCE. SCALE: 1/4" = V-0" TO 12'-0" A.F.F. CONTINUE PARTITION ABOVE IN VESTIBULE, SHOWN AS 3 DASHED LINE, TYP. TERMINATE WAINSCOT AT A2 REAR CENTER OF — POST, TYP. TYP. Ul � 11 ENLARGED PLAN / 15" ALIGN TOP OF CORNER ANGLE FLUSH W/ BOTTOM OF VESTIBULE CEILING OR G.B. OPENING. 15" 15" 96" 15" M38 FASTEN W/ EXPOSED BLK. 15" DRYWALL SCREWS & 358 CHROME FINISHING WASHERS, TYP. REFER TO PLANS FOR 15" LOCATIONS. OVER P. LAM. B-4 WAINSCOT NOTE: AT CORNERS WHERE ACUTE OR OBTUSE ANGLES OCCUR (AND STEEL ANGLES CANNOT BE USED), USE (2) 1-1/2" W. X 1/8" THK. X 96" H. GALV STL PLATES, OVERLAPPED. FASTENER TYPE AND SPACING SHALL BE THE SAME AS FOR THE CORNER ANGLE SHOWN ABOVE. WAINSCOT / CORNER ANGLE 8 ISOMETRIC SCALE: 1/2" = l'-0" STOCKROOM A PLAN NORTH ALIGN TOP OF CORNER ANGLE FLUSH W/ TOP OF WAINSCOT 14" M3 FASTEN W/ EXPOSED BLK. 14" DRYWALL SCREWS & CHROME 35 FINISHING WASHERS, TYP. REFER TO PLANS FOR LOCATIONS. 14" OVER P.LAM. B-4 WAINSCOT NOTE: AT CORNERS WHERE ACUTE OR OBTUSE ANGLES OCCUR (AND STEEL ANGLES CANNOT BE USED), USE (2) 1-1/2" W. X 1/8" THK. X 48" H. GALV STL. PLATES, OVERLAPPED. FASTENER TYPE AND SPACING SHALL BE THE SAME AS FOR THE CORNER ANGLE SHOWN ABOVE. WAINSCOT / CORNER ANGLE 7 ISOMETRIC SCALE: 1 /2" = 7'-0" -4- 6,111 — NICHE BY LANDLORD RECEIVING COUNTER 151 ELEVATION SCALE: l/4" = 1'-0" RECENING IN VESTIBULE, SHOWN AS STOCKROOM A DASHED LINE, TYP. A2 RTA';*; . STL. POST W/SELF LEVELING FOOT 141 SHOE AND N.T.S. STL. POST MAPLE BASE MIRROR PANEL VIEW N MEN o�0 00 00 00 00 00 olu —' N oi0 0'0 0'0 00 00 00 0i0 o &4 TERMINATION OF i TILE WALL AT 2'-0" TYP STOREFRONT I 0 N END CAP 13 ENLARGED ELEVATION — 358 SCALE: 1 1/2" = 17O IN VESTIBULE, SHOWN AS � DASHED LINE, TYP. — CONTINUE PARTITION ABOVE 2'-0" TYP WALL RAIL @ 9'-6" A.F.F. / o MEN TYP NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH, TYP. 1 O I ENLARGED PLAN `LAN 10 DASH MAPLE 64 DASH MAPLE VENEER PANEL VENEER PANEL J - - - - _ J _ � r ----------- NOTE: _—_-r___—NOTE: (2) SEPARATE PANELS ARE SHOWN SIDE BY SIDE. THESE PANELS SHOULD ALWAYS BE INSTALLED IN PAIRS, U.N.O. WOMEN'S MODULAR INFANT SHOE PANEL SHOE PANEL 40 DASH MAPLE VENEER PANEL 4'-0" WOMEN/YOUTH SHOE PANEL 6 P5 ELEVATION 5 P4 ELEVATION 4 P3 ELEVATION SCALE: 1/2" = 1'-0" SCALE: 112" = V-0" SCALE: 112" = V-0" �21 I STL. POST C.L. WALL RAIL @ 9'-6" A.F.F. 0 o 0 0 0 0 0 0 0 0 0 0 0. 0 0,0 010 00 0'0 0'0 00 Dill I, 2'-0" TYP. I, 12 ENLARGED ELEVATION SCALE: 1 712" = 1 '-0" 4� ancT A" 91 TYPICAL POST AND SHOE PANEL ENLARG STL. ANGLE PER FIXTURE NOTE: DRAWINGS (2) SEPARATE PANELS ARE SHOWN SIDE BY SIDE. THESE LINE OF FINISHED PANELS SHOULD ALWAYS BE FLOOR, TYP. INSTALLED IN PAIRS, U.N.O. MEN'S MODULAR SHOE PANEL MEN'S SHOE PANEL 3 P2 ELEVATION 2 P1 ELEVATION SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" FINISHED CORNER AT VESTIBULE END CAP 3 ---VESTIBULE CORNER TERMINATION OF TILE WALL AT _ STOREFRONT END CAP i STL. POST HANG RAIL \ MAPLE VENEER SHOE PANEL STL. CLIP r P%k II I A I (4) STL. CLIPS PER FIXTURE — DRAWINGS, TYP.. SCREW TOP o ROW CLIPS TO HANG RAIL WITH - SELF -TAPPING SCREWS, TYP. +I M TYPICAL SHOE PANEL SIDE ELEV, SCALE: 112 = 1'-0 MANN & MAHN A R C H I T E C T S I N C 3801 S CAPITAL OF TEXAS HW) SUITE 330 AUSTIN TX 7870,4 TEL: 512.912.7994 FAX: 512.912.7991 KEYNOTES 3. 5/8" TYPE'X' G.B., TYP. 26. (3) 3/4" x 12" x LENGTH SHOWN BLK. MELAMINE SHELVES ON STANDARDS/BRACKETS (18" o.c.) ON PTD. 1x3 HORZ. F.T. WD. FURRING. BOTTOM @ 48" A.F.F. 27. (2) 3/4" x 12" x 36" BLK. MELAMINE SHELVES ON (3) STANDARDS/ BRACKETS (18" ox.) ON PTD. 1x3 HORZ. F.T. WD. FURRING. BOTTOM @ 54" A.F.F. 35. GALV, STL. CORNER GUARD, 1/8" x 1-112" x 1-112" x 48" @ ALL 358. GALV. STL. CORNER GUARD, 1/8" x 1-112" x 1-112" x 96" @ 96" H. WAINSC( NO SHARP EDGES. COLS. & CORNERS. NO SHARP EDGES. 36. PTD. WD. 1x3 CLEAT W/(3) MOP HOOKS. MOP HOOKS TO BE MTD. AT TOP EDGE OF FRP PANEL. 57. 1-112" 0 SCHEDULE 40, PTD. BLK. STL. PIPE W/FITTINGS BY KEE KLAMP. 60. FIRE EXTINGUISHER: 2A/1 OBC RATING. 85. SAFE BOLTED TO THE FLOOR UNDER THE COUNTER, LOCATION AS DIRECTED BY THE STORE MANAGER. 88, GRAPHICS SNAP FRAME @ 43 1/8" A.F.F. 89. (2) HOOKS, (1) @ 54" A.F.F. & (1) @ 66" A.F.F. EMCO #D-10, SATIN CHROME, OR EC [EMCO INDUSTRIES (913) 492-74141 MOUNTED CENTERED ON CLEAR WALL SPACE. 90. PROVIDE A 2"0 BLACK GROMMET, CENTERED IN THE COUNTERTOP. 93, WHITE FRP PANEL WITH PEBBLE FINISH, TC EDGE AT 48" A.F.F., W/ ALL REQUIRED TR INCLUDING INSIDE CORNERS & TOP EDGE. INSTALL PER MANUFACTURERS SPECIFICAI MILLWORK KEYNOTES M8. 1-112" x 24" D. P. LAM. COUNTERTOP @ 36" A.F.F., WILSONART #1595-90, BLACK. (LEAD TIME FINISH) M38. 1-1 /2" x 24" D. P. LAM. COUNTERTOP @ 36" A.F.F., WILSONART #1595-90, BLACK. (LEAD TIME FINISH) SH -1. SHELF, 24" WIDE WM-24H. WALL MIRROR, 24" W, HANGRAIL MOUNT WM-24W. WALL MIRROR, 24" W, DIRECT WALL MOUP FIXTURE KEYNOTES P1. MEN'S SHOE PANEL P2. MEN'S MODULAR SHOE PANEL P3. WOMEN/ YOUTH SHOE PANEL P5. INFANT'S SHOE PANEL U1. 2" X 2" METAL POST FIXTURE NOTE: • REFER TO SHOP FIXTURE DRAWINGS FOR FURHTER INFORMATION. FINISHES B-1 BLACK COVE BASE, 4" HIGH B-2 BLACK COVE BASE, 6" HIGH B-4 MAPLE BASE, 2" HIGH PT -2 WHITE PAINT PT -3 BLUE PAINT PT -4 ZOLATONE PAINT dUL 1 2 2( ````��1lfflllfhNtll A: AR1 �1^ STATE of �il1/11(f411i��� All drawings, specifications, and designs J Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR FAwww.ff pH I$neine CLAY TERRACE CARMEL, IN SPACE #B 16 ENLARGED PLANS & DETAILS M&MA #4084 FINL STORE A6.1 #708 0 IT. P MS. ION T 04 9 DASH MAPLE VENEER PANEL 36 DASH MAPLE VENEER PANEL o ___I r ----I o STL. ANGLE PER FIXTURE NOTE: DRAWINGS (2) SEPARATE PANELS ARE SHOWN SIDE BY SIDE. THESE LINE OF FINISHED PANELS SHOULD ALWAYS BE FLOOR, TYP. INSTALLED IN PAIRS, U.N.O. MEN'S MODULAR SHOE PANEL MEN'S SHOE PANEL 3 P2 ELEVATION 2 P1 ELEVATION SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" FINISHED CORNER AT VESTIBULE END CAP 3 ---VESTIBULE CORNER TERMINATION OF TILE WALL AT _ STOREFRONT END CAP i STL. POST HANG RAIL \ MAPLE VENEER SHOE PANEL STL. CLIP r P%k II I A I (4) STL. CLIPS PER FIXTURE — DRAWINGS, TYP.. SCREW TOP o ROW CLIPS TO HANG RAIL WITH - SELF -TAPPING SCREWS, TYP. +I M TYPICAL SHOE PANEL SIDE ELEV, SCALE: 112 = 1'-0 MANN & MAHN A R C H I T E C T S I N C 3801 S CAPITAL OF TEXAS HW) SUITE 330 AUSTIN TX 7870,4 TEL: 512.912.7994 FAX: 512.912.7991 KEYNOTES 3. 5/8" TYPE'X' G.B., TYP. 26. (3) 3/4" x 12" x LENGTH SHOWN BLK. MELAMINE SHELVES ON STANDARDS/BRACKETS (18" o.c.) ON PTD. 1x3 HORZ. F.T. WD. FURRING. BOTTOM @ 48" A.F.F. 27. (2) 3/4" x 12" x 36" BLK. MELAMINE SHELVES ON (3) STANDARDS/ BRACKETS (18" ox.) ON PTD. 1x3 HORZ. F.T. WD. FURRING. BOTTOM @ 54" A.F.F. 35. GALV, STL. CORNER GUARD, 1/8" x 1-112" x 1-112" x 48" @ ALL 358. GALV. STL. CORNER GUARD, 1/8" x 1-112" x 1-112" x 96" @ 96" H. WAINSC( NO SHARP EDGES. COLS. & CORNERS. NO SHARP EDGES. 36. PTD. WD. 1x3 CLEAT W/(3) MOP HOOKS. MOP HOOKS TO BE MTD. AT TOP EDGE OF FRP PANEL. 57. 1-112" 0 SCHEDULE 40, PTD. BLK. STL. PIPE W/FITTINGS BY KEE KLAMP. 60. FIRE EXTINGUISHER: 2A/1 OBC RATING. 85. SAFE BOLTED TO THE FLOOR UNDER THE COUNTER, LOCATION AS DIRECTED BY THE STORE MANAGER. 88, GRAPHICS SNAP FRAME @ 43 1/8" A.F.F. 89. (2) HOOKS, (1) @ 54" A.F.F. & (1) @ 66" A.F.F. EMCO #D-10, SATIN CHROME, OR EC [EMCO INDUSTRIES (913) 492-74141 MOUNTED CENTERED ON CLEAR WALL SPACE. 90. PROVIDE A 2"0 BLACK GROMMET, CENTERED IN THE COUNTERTOP. 93, WHITE FRP PANEL WITH PEBBLE FINISH, TC EDGE AT 48" A.F.F., W/ ALL REQUIRED TR INCLUDING INSIDE CORNERS & TOP EDGE. INSTALL PER MANUFACTURERS SPECIFICAI MILLWORK KEYNOTES M8. 1-112" x 24" D. P. LAM. COUNTERTOP @ 36" A.F.F., WILSONART #1595-90, BLACK. (LEAD TIME FINISH) M38. 1-1 /2" x 24" D. P. LAM. COUNTERTOP @ 36" A.F.F., WILSONART #1595-90, BLACK. (LEAD TIME FINISH) SH -1. SHELF, 24" WIDE WM-24H. WALL MIRROR, 24" W, HANGRAIL MOUNT WM-24W. WALL MIRROR, 24" W, DIRECT WALL MOUP FIXTURE KEYNOTES P1. MEN'S SHOE PANEL P2. MEN'S MODULAR SHOE PANEL P3. WOMEN/ YOUTH SHOE PANEL P5. INFANT'S SHOE PANEL U1. 2" X 2" METAL POST FIXTURE NOTE: • REFER TO SHOP FIXTURE DRAWINGS FOR FURHTER INFORMATION. FINISHES B-1 BLACK COVE BASE, 4" HIGH B-2 BLACK COVE BASE, 6" HIGH B-4 MAPLE BASE, 2" HIGH PT -2 WHITE PAINT PT -3 BLUE PAINT PT -4 ZOLATONE PAINT dUL 1 2 2( ````��1lfflllfhNtll A: AR1 �1^ STATE of �il1/11(f411i��� All drawings, specifications, and designs J Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR FAwww.ff pH I$neine CLAY TERRACE CARMEL, IN SPACE #B 16 ENLARGED PLANS & DETAILS M&MA #4084 FINL STORE A6.1 #708 0 IT. P MS. ION T 04 J LLS ELECTRIC ROOM FLOOR V J TENANT ELECTRIC ROOM r q to ELEVATION - ELEGTR I G EGU I PMENT 50ALE:1/4"=1'-0" PONER RISER NOTES lO PROVIDE 3P200A CIRCUIT BREAKER IN LANDLORD'S DISTRIBUTION PANEL FOR NEW TENANT SERVICE. !�2 PROVIDE PANELBOARD, REFER TO SCHEDULE ON SHEET E-3. O3 PROVIDE 4#3/0+#6 GRD IN 2" CONDUIT. 4O PROVIDE 16 POLE, ELECTRICALLY HELD GONTACTOR "A" WITH 120V COIL CONTROL MODULE. SQUARE 'b" GLASS 6903. �5 PROVIDE AN ISOLATED 6ROUND I N6 BAR IN PANEL. EXTEND INSULATED 6ROUNDIN6 GONDUGTOR, 51ZED PER N.E.G., TO MAIN SERVICE GROUND OR TO THE DERIVED SYSTEM. REFER TO SPECIFICATIONS FOR FUSE TYPE AND GLASS. l�b PROVIDE 2 POLE TIME GLOCK FOR CONTROL OF STOREFRONT 516N 4 L16HTIN6 GONTAGTOR. O PROVIDE A 3 POLE LI6HTIN6 GONTAGTOR FOR CONTROL OF 5TORE LI6HTIN6. O EXTEND WIRING TO SINGLE POLE SWITCH LOCATED IN THE OFFICE. REFER TO SHEET E-2 FOR EXACT LOCATION. O GOORDINATE ALL WORK WITH LL REPRESENTATIVE PRIOR TO START OF WORK. 10 CONTRACTOR SHALL FIELD VERIFY EXISTING ELECTRIC SERVICE PRIOR TO BIDDING THE PROJECT. CONTACT THE PROJECT ARCHITECT AND ENGINEER WITH ANY 12I5GREPANCIE5 OF THE El EGTRIGAL SERVICE IN THE FIELD WITH THAT INDICATED IN THE BID/GON5TRUGTION DRAWIN65. II PROVIDE 45 KVA TRANSFORMER MOUNTED FROM STRUCTURE ABOVE. REFER TO TRANSFORMER 5GHEDULE ON TH15 SHEET. AUDI O NOTES GENERAL GONTRAGTOR TO PROVIDE THE FOLLOWING: 1. MOUNT EMPTY SINGLE JUNCTION BOX O 65" A.F.F. IN MANAGER'S OFFICE, ABOVE DESK. 5TUB 3/4" EMPTY CONDUIT TO ABOVE GEILIN6 NEAR DEGK/57RUCTURE. LOCATE ADJACENT TO FLUSH MOUNTED 20 AMP DUPLEX OUTLET (ABOVE DESK O 66' A.F.F) 2. NON-GOMBUSTIBLE WOOD OR METAL BLOGKIN6 NEEDS TO BE IN PLACE BEFORE GYPSUM BOARD 15 INSTALLED. 3. MOUNT ONE SINGLE DEEP JUNCTION BOX AT GA514WRAP FOR VOLUME CONTROL. 4. PROVIDE 3/4" CONDUIT TO RUN IN PARTITION FROM BEHIND El EGTRONIGS RACK TO GASHhU2AP FOR VOLUME CONTROL. LEAVE PULL 5TRIN6 IN CONDUIT. 5. STOCKROOM VOLUME CONTROL- * PROVIDE 3/4" CONDUIT TO RUN IN WALL FROM BEHIND ELECTRONIGS RACK TO MANA6ER'S OFFICE FOR STOCKROOMS 10 WATT VOLUME GONTROL. LEAVE PULL 5TRIN6 IN CONDUIT. * MOUNT SINGLE DEEP JUNCTION BOX ADJACENT TO L16HT SWITCH IN MANA&ER5 OFFICE FOR STOCK ROOM VOLUME CONTROL. PLAYNETWORK TO PROVIDE THE FOLLOWING: I. PLAYNETWORK SYSTEM ELEGTRONIGS AND WIRE CONNECTIONS TO BE INSTALLED BY A PLAYNETWORK CERTIFIED SOUND CONTRACTOR. 2. SYSTEMS ELECTRONIC RACK TO BE MOUNTED IN STOCK ROOM, ADJACENT TO ELECTRICAL EQUIPMENT. 3. GENTER OF PLAYNETP40W SYSTEM El EGTRONIGS RACK SHALL BE MOUNTED O 44" A.F.F. IN STOCKROOM. 4. REFER ANY QUESTIONS TO DAVID PARKER AT PLAYNETWORK, I -888 -561 -PLAY (7529) EXT. 238. SEGURITY NOTES GENERAL GONTRACTOR TO PROVIDE THE FOLLOWING: I. PASSIVE INFRARED DEVICE AT THE STOREFRONT. PROVIDE A 51N6LE &ANG JUNCTION BOX ABOVE THE GEILIN6 NEAR THE ENTRY, ABOUT 16" ABOVE THE GEILIN6, MOUNTED TO THE METAL STUD FRAMING. 2. CAMERA DOMES LOCATED IN THE SALES AND STOCK AREA. CAMERA DOMES, FURNISHED BY THE 6ENERAL CONTRACTOR INSTALLED BY THE ELECTRICAL GONTRAGTOR. TOP OF DOME TO BE LOCATED AT BOTTOM OF LI644TIN6 ELEVATION OR LOWEST GEILIN6 ELEVATION WITHIN 25'-0", WHICHEVER 15 LOWER DOME 15 PENDANT MOUNTED WITH CONDUIT .SWAY BRAGS A5 REQUIRED. PROVIDE RG -59 COAXIAL GABLE IN CONDUIT WITH 3'-0" OF SLACK AT DOME AND 20'-0" OF SLACK IN SECURITY JUNCTION BOX AT THE ELECTRICAL PANELS. PROVIDE 2 GONDUGTOR 16 GAUGE IN SAME CONDUIT WITH THE SAME SLACK AS THE COAXIAL GABLE. 3. ALARM KEYPADS FOR SECURITY SYSTEM. LOCATED AT THE 5ALE5/5TOGK DOOR AND THE REGEIVIN6 DOOR IN THE STOCKROOM. PROVIDE A SINGLE &AN& JUNGTION BOX MOUNTED HORIZONTALLY 48' AFF. SURFACE MOUNT JUNCTION BOX IN STOCKROOM IF WALL 15 CMU OR UNABLE TO FLUSH MOUNT. 4. SECURITY HORN AND STROBE LOGATED ABOVE THE DOOR FROM THE SALES TO STOCK ROOM. PROVIDE RECESSED JUNCTION BOX 14'-0" AFF, CENTERED ABOVE THE DOOR (ON SALES SIDE OF DOOR) FOR HORN. PROVIDE RECESSED JUNCTION BOX II' -0" AFF, CENTERED ABOVE THE DOOR (ON SALES SIDE OF DOOR) FOR STROBE. 5. DOOR CONTACT LOCATED AT RECEIVING DOOR IN STOCK ROOM. PROVIDE 1/2' CONDUIT FROM SECURITY JUNCTION BOX AT ELECTRICAL PANELS, TO TERMINATE I" ABOVE DOOR FRAME, LATCH 51DE IN51DE STOCK ROOM. 6. PROVIDE PULL 5TRIN65 IN ALL EMPTY GONDUIT5. LABEL ALL CONDUITS AND LABEL PULL 5TRIN65 AT EACH END. 1. 5EGURITY JUNCTION BOX LOGATED AT ELECTRICAL PANELS. PROVIDE A 12"x12"x6"D JUNCTION BOX MOUNTED 6'-0' AFF TO BOTTOM ON THE WALL, ABOVE THE ELECTRICAL PANEL AREA. ALL SECURITY CONDUIT HOME -RUNS 15 TO TERMINATE IN TOP OF JUNGTION BOX. PROVIDE PERMANENT LABEL ON FRONT OF JUNCTION BOX TO READ 'SECURITY GABLE ONLY'. 5. ALL SECURITY DEVICES ARE TO BE FURNISHED AND INSTALLED BY THE TENANTS ALARM CONTRACTOR, UNLESS NOTED OTHERWISE. TENANTS SECURITY VENDOR TO MAKE ALL FINAL CONNECTIONS. L. I C HT I NC FIXTURE 5GHEDUL.E TYPE MOUNTING LAMPS DESCRIPTION CATAL06 # VOLTS G PENDANT 2-F32 4' LINEAR FLUORESCENT TROFFER WITH L160TOLIER 120 12 125% I5 T8 SEMI-SPEGULAR PARABOLIC LOUVER AND #PLM6PIOL5 HEATING •' 51.0 100% 51D WATER HEATER ELECTRONIC BALLAST. 24012050 M15GELLANEOU5 LOADS GI PENDANT 2-F32 4' LINEAR FLUORESCENT TROFFER WITH L1614TOLIER 120 155.77 AMPS 1055 AMPS T8 SEMI -SPECULAR PARABOLIG LOUVER, #PLM6PIOL5 PANELBOARD 120/208 VOLTS-M.H. 6-6" TO TOP ® PANELBOARD 120/208 VOLT5-M.H. 6-6" TO TOP ELECTRONIC BALLAST 4 BATTERY BACKUP 24012050EM G2 RECESSED 2-F32 4' LINEAR FLUORESCENT TROFFER WITH LI&HTOLIER 120 MOTOR-51146LE PHASE, THREE PHASE LOAD AS NOTED ® T8 5EMI-5PECULAR PARABOLIC LOUVER, #PLA8610L5 DOOR BELL Q DOOR BELL, PU5HBUTTON M.H. 6-9" ELECTRONIC BALLAST. 24012050 ® G3 REGE55ED 2-F32 4' LINEAR FLUORE5GENT TROFFER WITH LI&HTOLIER 120 OF GONDUGTOR5 WHEN MORE THAN 3. 0 T8 SEMI-5PEGULAR PARABOLIC LOUVER, #PLA8610L5 QD S (Z) R FIRE ALARM - DUCT SMOKE DETECTOR 5UPPLY, RETURN K❑ SECURITY KEYPAD - M.H. 48" ELECTRONIC BALLAST 4 BATTERY BACKUP 24012050EM l�J E CHAIN 2-F32 4' FLUORE5GENT STRIP FIXTURE WITH L16HTOLIER 120 PA561VE INFRARED DEVICE © T8 ELECTRONIC BALLAST. #5W232 12050 EI 5URFAGE 2-F32 4' FLUORE5GENT STRIP FIXTURE WITH L16 4TOLIER 120 T8 ACRYLIC PRISMATIC LENS AND #KLT232 ELEGTRONIG BALLAST. 12050 E2 SURFACE 1-F32 4' FLUORESCENT STRIP FIXTURE WITH L16HTOLIER 120 T8 ELECTRONIC BALLAST. #OW132 12050 F RECESSED 1-60W INCANDESCENT DOWNLI6HT WITH CLEAR LI&HTOLIER 120 PAR38 ALZAK REFLECTOR. #1102PI/1113 HIR FL H TRACK 1-60W INCANDESCENT TRACK HEAD FIXTURE LI&HTOLIER 120 PAR36 FINISHED IN BLACK. (PROVIDE WHITE #90225K HIR FL FIN15H AS NOTED) H3 SURFACE 1-60W INCANDESCENT TRACK HEAD FIXTURE LI&HTOLIER 120 PAR36 MOUNTED ON MONOPOINT. WHITE FIN15H #g02213K HIR FL IN SALE AREA, BLACK FINISH FOR ALL #61a05K STOREFRONT AREA FIXTURES. TRACK 5URFAGE 51N6LE CIRCUIT TRACK FINISHED IN BLACK. LI614TOLIER 120 PROVIDE ALL FITTIN65, CONNECTORS, #60005K SUPPORTS, FEEDS, ETC. PROVIDE WHITE SERIES FINISH AS NOTED) TRACK REGE55ED SINGLE GIRGUIT TRACK (BASIG) INSIDE LI614TOLIER 120 RECESSED TRACK HOU51N6, ALL FINISHED #1511 WH SPLICE BOX IN WHITE. PROVIDE ALL FITTIN65, #7515 WH 4' HOU51N6 CONNECTORS, SUPPORTS, FEEDS, ETC #'7516 WH 8' HOUSING (HOUSING LENGTH BASED ON LAYOUT) #6000WH 5ERIE5 L SURFACE INGLD. SELF CONTAINED EMER6ENGY BATTERY EMER61-LITE 120 UNIT WITH INTE6RAL BATTERY/GHAR6ER. #EG -2 SERIES M UNIVERSAL LED EDGE -LIT EXIT SIGN WITH INTEGRAL LIGHT ALARM 120 RECESSED BATTERY/GHAROER AND FLA5HIN6 #5PLED-B-RW-D INTERFACE N UNIVERSAL LED LED AELF-POWERED EXIT 516N WITH LITHONIA 120 INTEGRAL BATTERY/GHAR6ER #LQMSWIRI20 F4 SURFACE 2-F32 4' FLUORE5GENT STRIP FIXTURE WITH LI614TOLIER 120 T8 A5YMETRIGAL REFLECTOR AND #SW24OR5120OG ELECTRONIC BALLAST. NOTE: ALL L16HTIN6 FIXTURES AND LAMPS SHALL BE FURNISHED BY THE 6ENERAL CONTRACTOR, INSTALLED BY THE ELECTRICAL CONTRACTOR. GONTRAGTOR FURNISH AND INSTALL ALL SUPPORTS, RODS, CHANNELS, ETC. REQUIRED TO INSTALL ALL L16HT FIXTURES. E<LEwGTRIGAL LOAD SUMMAR'r LOAD CONNECTED KVA DEMAND DEMAND FAG TOR KVA LI6HTIN6 18.2 125% 22.8 REGEPTACLE5 6.6 « 6.6 SIGN 12 125% I5 AIR CONDITIONING 00 46.9 100% 48.9 HEATING •' 51.0 100% 51D WATER HEATER 2.0 100% 2.0 M15GELLANEOU5 LOADS --- 100% -- TOTAL 121.9 KVA 87.8 KVA 155.77 AMPS 1055 AMPS 0 FIRST 10.0 KVA AT 100%, BALANCE OF LOAD AT 50% KVA (NEC 220-13) ** HEATING AND AIR GONDITIONIN6 ARE NON-51MULTANEOU5 LOAD 000 ALL TRACK LI&HTIN6 LOAD5 BASED ON 2002 NATIONAL ELECTRIC CODE OF 15 WATT5/LINEAR FOOT OF TRACK. DRY TYPE TRANSFORMERS - 5 PRIMARY: 480V DELTA 5EGONDARY: 120/208\/ WYE KVA G/B GONDUGTOR5-G. GRD G/B GONDUGTOR5-G. GRD 45 3P TOA 3#4-1 "G #8 I 3PI50A 4#2/0-21IG #4 TRANSFORMER NOTE5: I. GROUND PRIMARY 4 5EGONDARIES PER NEG. 2. ALL GONDUIT5 SHALL BE FLEXIBLE. 3. 5EGONDARY GONDUGTOR5 SHALL NOT EXCEED 10 FEET LONG TO F I R5T OVERGURRENT PROTEGTI ON DEV I GE. ELEGTR I GAL. 5"rMBOL.S LIST NOTE: ALL MOUNTING HE16HT5 ARE TO GENTER LINE OF THE OUTLET BOX UNLESS OTHERK15E INDIGATED. SYMBOL DESGRIPTION 0 FIXTURE-FLUORE56ENT-GEILIN6, TEXT DENOTES FIXTURE TYPE 0NL DENOTES FIXTURE ON N16HT LIGHT CIRCUIT O FIXTURE-INGANDESGENT-GEILIN6, TEXT DENOTES FIXTURE TYPE Ap FIXTURE -TRACK LI&HTIN6 ® ®I EXIT LIGHT-GEILIN6, WALL, WITH DIRECTIONAL ARROWS LL EMERGENCY BATTERY UNIT, CONNECTED AHEAD OF SWITCH. M 5WITGH-MOTOR RATED DATE RECEPTAGLE-20A-125 VOLT5-51MPLEX, DUPLEX, DOUBLE Qj e # DUPLEX M.H. 20" UNLESS NOTED OTHERWISE, 'W" DENOTES MAMA #4084 WHITE IN COLOR 0 REGEPTAGLE-20A-125 VOLT5-GEILIN6 MOUNTED Q❑ JUNCTION BOX d OUTLET -DATA -WALL OUTLET -TELEPHONE -WALL TELEPHONE TERMINAL BAGKBOARD PANELBOARD 120/208 VOLTS-M.H. 6-6" TO TOP ® PANELBOARD 120/208 VOLT5-M.H. 6-6" TO TOP BRANCH GIRGUIT-IN GEILIN6 OR WALLS 3#12 UNLESS BRANGH CIRCUIT -IN FLOOR NOTED OTHERWISE ® ® MOTOR-51146LE PHASE, THREE PHASE LOAD AS NOTED ® HEATIN6 ELEMENT-GAPAGITY AS NOTED Q DRAWIN6 NOTE DOOR BELL Q DOOR BELL, PU5HBUTTON M.H. 6-9" © GONTACTOR ® CONTROL DEVIGE BY EQUIPMENT CONTRACTOR HOMERUN TO PANEL -LETTER AND NO. INDICATES CIRCUIT NUMBER. NO. OF GR055LINE5 INDICATES NO. OF GONDUGTOR5 WHEN MORE THAN 3. 0 LOW VOLTAGE TRANSFORMER E' ®' D15GONNEGT 5WITGH-UNFU5ED, FU5ED-M.H. 6'-6" TO TOP QD S (Z) R FIRE ALARM - DUCT SMOKE DETECTOR 5UPPLY, RETURN K❑ SECURITY KEYPAD - M.H. 48" ® SECURITY GAMERA DOME l�J 5EGURITY HORN - M.H. 14'-0" AFF 5 SEGURITY STROBE - M.H. II'O" AFF SECURITY DOOR CONTACTS IR PA561VE INFRARED DEVICE © TIME GLOGK ABBREVIATIONS, AFF - ABOVE FINISHED FLOOR G - CONDUIT DW6 - DRAWING EF - EXHAUST FAN EWG - ELECTRIC WATER COOLER GRD 6FI - GROUND - 6ROUND FAULT INTERRUPTER 16 - ISOLATED 6ROUND LL -LANDLORD MH - MOUNTIN6 HE16HT MTD - MOUNTED NEC - NATIONAL ELECTRIC CODE NL - N16HT LIGHT RTU - ROOF TOP UNIT W/ - WITH XR - EXISTING TO REMAIN NOT I GE TO GONTRAGTORS : ALL CONTRAGTORS PRIOR TO BID SUBMISSION PROCESS SHALL VISIT PROPOSED WORK SITE AND FIELD VERIFY ALL EXISTING CONDITIONS. ANY CONDITION THAT DIFFERS FROM THAT SHOWN ON THESE PLANS SHALL BE REPORTED TO TENANTS ARGHITEGT/EN6INEER 50 THAT NEW AND REVISED BID DRAWIN65 OR INFORMATION MAY BE ISSUED. MODIFICATIONS TO SCOPE OF WORK WHICH RESULTS FROM CONTRACTORS NEGLECT TO V151T THE SITE PRIOR TO 5UBMITTIN6 BID, SHALL BE THE GONTRAGTOR5 501E RESPONSIBILITY. FI r„ ►_ y: /:Ems_ll__ �: i ARCHITECTS I NC 5.501 5 CAPITAL OF TEXA5 HAY 5U I TE 330 AU5T I N TX 78704 TEL: 512.Q 12.7aa4 FAX: 512.912.7ag5 DON PENN CONSULTING ENGINEER 8060 HO WAY SM SURE 101 GRAPEVINE, TEXAS 700 SR -410.2868 FAX O17,Z61-8411 'JUL 12 2004 Kp.,o _ �', S r OF FI r„ ►_ y: /:Ems_ll__ �: i ARCHITECTS I NC 5.501 5 CAPITAL OF TEXA5 HAY 5U I TE 330 AU5T I N TX 78704 TEL: 512.Q 12.7aa4 FAX: 512.912.7ag5 DON PENN CONSULTING ENGINEER 8060 HO WAY SM SURE 101 GRAPEVINE, TEXAS 700 SR -410.2868 FAX O17,Z61-8411 'JUL 12 2004 06.30.04 PERMIT, L.L. REVIEW 4 SID DATE 155UED FOR • �n�s ne CLAY TERRACE CARMEL, IN 5PAGE #516 SYMBOL5 LIST/ SGHEDULES � R15�R MAMA #4084 E-� Fl% STORE #lob LOCATION OF El EGTRIGAL 5TUB-UP. CLUSTER CONDUITS TIGHT TOGETHER. COORDINATE EXACT LOGATION/DIMEN5ION WITH HILLTOP WOODSHOP. CONDUITS MUST GOME UP IN THE CABINET AREA "UNDER THE P.O.S." NOT IN THE OPEN TRASH GAN AREA. PU5H5UTTON (241/) EDWARDS #600 (DOORBELL "B") • 1 16 1 PROVIDE 51N6LE DEEP JUNCTION BOX FOR VOLUME CONTROL VERIFY LOCATION I EXTEND TO PUUL�. T AT � I ANI — r . A Ci w /�I 1� 1–� SERVVIICE ODOOR– SGALE: 1/4"=1'-0" COORDINATE EXACT LOCATION OF 5TU5-IN5, P.0.5. OUTLETS, GENERAL PURP05E OUTLETS, SHOWCASE L1644TIN6, PU5HBUTTON, ETC. WITH MILLWORK DRAWIN65. RUN CONDUIT AND WIRIN6 IN DATA/POWER CHASE WITHIN GASH WRAP AS NOT TO INTERFERE WITH THE OPERATION OF THE DRAWERS. CONGEAL ALL WIRIN6 FROM CUSTOMERS VIEW. MAKE ALL FINAL CONNECTIONS AS REQUIRED. T RA MOUNTED FROM STRUCTURE ABOVE FART FLAN - ELEGTR I G EGU I Ply ENT SCALE: I/4"= I' -O" r O ICE FART PLAN SCALE: EXTEND TO PUSHBUTTON AT GASH WRAP — E39 ELECTRICAL EQUIPMENT REFER TO PART PLAN ON TH15 51' WATER HEATER (ABOVE TOILET RM) 2.0 KW, 120V 159 RA -14 VIA CD FCAER r-LOOR FLAN 15 LIC7H7INC7 �LOOR FLAN SGAL.E: I /8"=1 '-O" SCALE: IRAN I NO MOTES OI MOUNT RECEPTAGLE HORIZONTALLY, CENTERED IN THE BASE OF THE ROLL -UP DOOR COLUMN. O2 COORDINATE EXACT LOCATION IN THE FIELD AND MAKE ALL FINAL CONNECTIONS TO 516N. [�3 PROVIDE LOW VOLTA6E TRANSFORMER, 120-24 VOLTS. EDWARDS #664 (24V-20VA). MOUNT AS HIGH AS POSSIBLE. O4 PROVIDE LOW VOLTA6E 516NAL BELL (24V).EDWARD5 340 SERIES. MOUNT TO BOTTOM OF DECK ABOVE. O5 PROVIDE 3/4" CONDUIT TO DATA TERMINATION POINT AT TELEPHONE BAGKBOARD. TURN CONDUIT DOWN TO TOP OF TELEPHONE BACKBOARD. TERMINATE CONDUIT WITH NYLON BU5HIN6 AND PULL5TRIN6. OPROVIDE 5146LE 6AN6 DOUBLE DEEP JUNCTION BOX ADJACENT TO LIGHT SWITCH WITH 3/4" EMPTY CONDUIT TO AUDIO RACK NEAR THE TELEPHONE PANEL. TERMINATE CONDUIT WITH NYLON BUSHING AND PULLSTRIN6. (FOR AUDIO SY5TEM). OPROVIDE A I" CONDUIT IN FLOOR SLAB FOR FUTURE USE. TERMINATE CONDUITS WITH NYLON BUSHING AND PULL5TRIN6. O8 POWER FOR P.0.5., PROVIDE A SEPARATE NEUTRAL AND 150LATED 6ROUND FOR EACH GIRGUIT. OPROVIDE A 1 1/4" CONDUIT TO DATA TERMINATION POINT, AT TELEPHONE BACKBOARD. TERMINATE CONDUIT WITH NYLON BUSHING AND PULL5TRING. 10 POWER FOR GONVENIENGE RECEPTACLES. II COORDINATE ROUTING OF CONDUIT AND WIRE IN FLOOR SLAB WITH LANDLORD REPRESENTATIVE PRIOR TO BID AND ROUGH -IN. 12 GOORDINATE EXACT LOCATION OF STUB -INS, P.0.5. OUTLET5, GENERAL PURPOSE OUTLETS, SHOWCASE LIGHTIN6, PUSHBUTTON, ETC. WITH MILLWORK DRAWIN65. RUN CONDUIT AND WIRIN6 IN DATA/POWER CHASE WITHIN GASH WRAP AS NOT TO INTERFERE WITH THE OPERATION OF THE DRAWERS. GONCEAL ALL WIRIN6 FROM CU5TOMER5 VIEW. MAKE ALL FINAL CONNECTIONS AS REQUIRED. 13 PROVIDE 1/2" CONDUIT WITH DOOR BELL SYSTEM "B" WIRIN6, EXTEND TO DOOR BELL "B" IN STOCK ROOM. 14 PROVIDE A 51N&LE POLE 5WITGH FOR CONTROL OF 5ALE5 AREA L16HTIN6 CONTAGTOR. REFER TO POWER RISER ON SHEET E -I. PROVIDE PLA5TIG LAMINATED NAMEPLATE TO READ "5ALE5 AND 5TOGK AREA LICHTIN6". REFER TO SPECIFICATIONS FOR DETAILS. 15 GONTRAGTOR SHALL REFER TO ARCHITECTURAL REFLECTED GEILIN6 PLAN FOR ,EXAGT LOCATION OF L16HTIN6 FIXTURES, GRID COORDINATION AND AIMING OF LIGHTING FIXTURES. I6 CONNECT ALL EXIT 516N5, EMER&ENGY BATTERY UNITS AND NIGHT LIGHTS (NU IN THE STOCK ROOM WITH 2#10+6RD TO DEDICATED CIRCUIT RA -16. MOUNT BATTERY UNITS IN THE 5TOGK ROOM 12b" AFF TO BOTTOM. 17 CONNECT ALL EXIT 516N5, EMERGENCY BATTERY UNITS AND N16HT LIGHTS (NL) IN THE 5ALE5 AREA WITH 2#10+GRD TO DEDICATED GIRGUIT RA -18. 18 PROVIDE A BLACK DUPLEX RECEPTACLE MOUNTED FLUSH IN GEILIN6, CIRCUIT RA-Iq. Iq PROVIDE 3/4" CONDUIT WITH PULLSTRIN6 FROM THE AUDIO EQUIPMENT RACK TO THE VOLUME CONTROL JUNCTION BOX IN THE GASH WRAP FOR VOLUME CONTROL. 20 JUNGTION BOX MOUNTED FLUSH IN THE GEILIN6 NEAR THE ENTRY, ABOUT 24" OFF THE DOOR ENTRY AND 36" DEEP HEADING INTO THE STORE FOR SEGM17 Y INFRA -RED DETECTOR. EXTEND 3/4" EMPTY CONDUIT WITH PULLSTRING FROM JUNCTION BOX TO THE SECURITY PANEL MOUNTED NEXT TO THE TELEPHONE PANEL. 21 PROVIDE A 5146LE &ANG JUNCTION BOX, MOUNTED 60" AFF WITH 3/4" EMPTY CONDUIT TO ABOVE GEILIN6, NEAR TO THE DECK/STRUCTURE. MOUNT NEXT TO THE RECEPTACLE ABOVE THE DESK. 22 PROVIDE A DUPLEX REGEPTAGLE FOR TV MONITOR AT ENTRY. LOCATE OUTLET 14'-0" AFF, 8'-0" IN51DE THE ENTRY, CENTERED ON THE OVERHEAD GRILLE OPENIN6. PROVIDE BLACK DEVICE WITH BLACK GOVERPLATE. 23 CAMERA DOMES FURNISHED BY THE GENERAL GONTRAGTOR, INSTALLED BY THE ELECTRICAL CONTRACTOR TOP OF DOME TO BE LOCATED AT BOTTOM OF LIGHTING ELEVATION OR LOWEST GEILIN6 ELEVATION WITHIN 25'-0", WHIGHEVER 15 LOWER. DOME 15 PENDANT MOUNTED WITH CONDUIT SWAY BRACE AS REQUIRED. PROVIDE R6 -5q GOAXIL GABLE IN CONDUIT WITH 3'-0" OF SLACK AT DOME AND 20'-0" OF SLACK IN SECURITY JUNCTION BOX AT THE ELECTRICAL PANELS. PROVIDE 2 CONDUCTOR 18 6AU6E IN SAME CONDUIT WITH THE SAME SLACK A5 THE GOAXIL GABLE. 24 PUSHBUTTON (24V) EDWARDS #600 (DOORBELL "A") 25 AUDIO/TELJDATA/SEGURITY EQUIPMENT MOUNTED ABOVE DOOR. REFER TO ELEVATION PART PLAN ON SHEET E-3. 26 AIR HANDLING UNIT (INDOOR)- 6.0 MGA, 15A MOGP 480V 34?. OAIR HANDLING UNIT (OUTDOOR)- 42.1 MGA, 50A MOGP 460V 34). 28 DUCT HEATER - 50.0 KW, MOCP 480V 310. 2q PROVIDE WEATHERPROOF/6FI DUPLEX RECEPTACLE MOUNTED AT AIR HANDLIN6 UNIT, CIRCUIT RA -1-1. OSMOKE DETECTOR MOUNTED IN SUPPLY AND RETURN DUCTS OF AIR HANDLING UNIT. 31 WALL MOUNTED HEATER - 1.0 KW, 12OV. ►I /MANN A MANN A R C H I T E C T S I N C 3801 5 CAPITAL OF TEXAS HAY 51JI TE 330 AU5T I N TX 75704 TEL: 512.cf12.7ag4 FAX: 512.g12.7g45 DON PENN CONSULTING ENGINEER 8060 HIGHWAY M SUITE 101 GRAPEVINE, TOM 78061 817-410-280 FAX OV -261-8411 2 2004 O o oJE ►I /MANN A MANN A R C H I T E C T S I N C 3801 5 CAPITAL OF TEXAS HAY 51JI TE 330 AU5T I N TX 75704 TEL: 512.cf12.7ag4 FAX: 512.g12.7g45 DON PENN CONSULTING ENGINEER 8060 HIGHWAY M SUITE 101 GRAPEVINE, TOM 78061 817-410-280 FAX OV -261-8411 2 2004 06.30.04 PERMIT, L.L. REYIEW 4 BID DATE 155UED FOR 0 � ne CLAY TERRACE CARMEL, IN 5PAGE #516 FLOOR FLAN5 FICAER $ L I GHT I NG MAMA #4054 E-2 EINL STORE #105 CONCRETE INSERT APPROVED FOR PURPOSE. SECURELY ANCHOR TO CONCRETE SLAB/DEGK (TYPICAL) 61 MAXIMUM FROM END OF TRACK — BOLT THREADED ROD TO FIXTURE 4'-0" MAXIMUM SPAGIN6 OF THREADED RODS 3/8" DIAMETER THREADED ROD (TYPJ (LEN6TH AS REQUIRED) UNI5TRUT, JOIST OR BEAM CLAMP (ATTACH TO TOP CHORD) APPROVED FOR PURPOSE PROVIDE UNISTRUT TO SPAN BETHEEN STRUCTURE MEMBERS AS REQUIRED STEEL BEAM AND/OR BAR JOIST SYSTEM. VERIFY IN FIELD 3/8" DIAMETER THREADED ROD (TYPJ (LEN6TH AS REQUIRED) SIN61-E CIRCUIT TRACK OR SUSPENDED L16hfiT FIXTURE TRAG< AND SUSPENDED Ll OHT1NO MOUNTI NO DETAIL NO SGALE * ELECTRICAL CONTRACTOR SHALL VERIFY IN THE FIELD IF GEILIN6 15 CONCRETE DECK OR METAL PAN 5Y5TEM TO DETERMINE APPROPRIATE MOUNTING DETAIL. DO NOT SUSPEND FROM ROOF DECKS. * ELECTRICAL CONTRACTOR SHALL PROVIDE SWAY BRAGE5 IF REQUIRED BY CODE. JO15T/13EAM CLAMP (ATTAGH TO TOP CHORD) APPROVED FOR PURPOSE CONCRETE INSERT (TYP I GAL OF 4) APPROVED FOR PURPC SECURELY ANCHOR TO GE I L I NO STRUCTURE (NPI GAL' STRUCTURE HUNG TRANSFORMER - BOLT TRANSFORMER TO 'G' 1633 6.5 1631265116.3!26 42.8 42.8 42.4 128.0 PROVIDE 1/2" CONTINUOUS THREADED HANGER ROD - FOUR (4) MINIMUM (LENGTH TO BE DETERMINED IN FIELD). PROVIDE VIBRATION ISOLATORS (TYPICAL) T PROVIDE STEEL 'G' GHANNEL (1/4" THIGK x 4") SUPPORT FOR TRANSFORMER 8'-O" AFF \ PROVIDE VENTILATED CLOSURE PLATE ON BOTTOM DET,41 L -STRUCTURE HUNS TRANSFORMER NO SCALE r 'JUL 12 20'04 i • • • • -It �11 m = '- _• 06.50.04 PERMIT, L.L. REVIEW 4 BID DATE 155UED FOR ©- - -• nmii�ii.�©ii.�iiv MAMA #4084 E-3 - - nm ©" OQ7�/✓zzjVZO,0'0 M- 74-- ■m 0 - ■■%/%/%///%■■� - ■■ 0 - ■■■■%/✓///.%///%m - ■■ VZZZZ, 0,0 HEM MUFM © ■■;/zzzl101✓W0m " ■■ jV/Z/� ■■0/✓/N0v///zi■U■m rm 2 1 rz i m i a I rz�m -_ ■■ ® ■■��/✓���//��i® ■■ ® ■■pO��i 0/zzzm ■■ HEM ® - • • Oma/✓����.VZi-n i m ED■■■■%/✓//%///%m HEM 71■■ D - ■■/NOW)■■%/✓//0 " ■■ m - ■■R/.�ZOMUNRO■■m - ■■ JO15T/13EAM CLAMP (ATTAGH TO TOP CHORD) APPROVED FOR PURPOSE CONCRETE INSERT (TYP I GAL OF 4) APPROVED FOR PURPC SECURELY ANCHOR TO GE I L I NO STRUCTURE (NPI GAL' STRUCTURE HUNG TRANSFORMER - BOLT TRANSFORMER TO 'G' 1633 6.5 1631265116.3!26 42.8 42.8 42.4 128.0 PROVIDE 1/2" CONTINUOUS THREADED HANGER ROD - FOUR (4) MINIMUM (LENGTH TO BE DETERMINED IN FIELD). PROVIDE VIBRATION ISOLATORS (TYPICAL) T PROVIDE STEEL 'G' GHANNEL (1/4" THIGK x 4") SUPPORT FOR TRANSFORMER 8'-O" AFF \ PROVIDE VENTILATED CLOSURE PLATE ON BOTTOM DET,41 L -STRUCTURE HUNS TRANSFORMER NO SCALE r 3.cl! 5.51 6.11 3:11 3.q1 5S q 8 q.8 q.4 2q.0 « PROVIDE LOCK CLIP ON CIRCUIT BREAKER ** EXTEND VIA GONTAGTOR "A" PROVIDE 3/4" FIRE TREATED PLYWOOD BACKBOARD, 4' HIGH AND 8'-0" LONG, MOUNTED 7'-4"" AFF FOR TELEPHONE, AUDIO DATA AND SECURITY SERVICE TERMINATION. WHERE DATA GABLES COME BACK TO TERMINATION BOARD, 6.G. PROVIDE PORT PATCH PANEL TO NETWORK HUB. FINAL CONNECTIONS BY TENANT'S DATA CONTRACTOR. I 18" L_ QUAD 1.6. OUTLET r--- ---r— --_ —�_ CIRCUIT RA -6----L, L �I I —I II 1 ON OUTLINE OF SECURITY JUNCTION BOX OUTLINE OF SECURITY PANEL BY TENANT'S CONTRACTOR OUTLINE OF TELEPHONE PANEL GIR.'.UIT RA -20 OUTLINE OF AUDIO EQUIPMENT RACK BY TENANT'S CONTRACTOR QUAD I.G. OUTLET CIRCUIT RA -10 NETWORK HUB AND PATCH PANEL PRODDED BY 6.G. MOUNT SOLID DIRECTLY TO PLYWOOD ELEVATION - AUDIO/TELE/SEGUR I T'i' EGU I P . 50ALE:1/4"=1'-0" 'JUL 12 20'04 • • i • • - MITI m = '- _• 06.50.04 PERMIT, L.L. REVIEW 4 BID DATE 155UED FOR ©- - -• nmii�ii.�©ii.�iiv MAMA #4084 E-3 - - nm ©" OQ7�/✓zzjVZO,0'0 M- 74-- ■m VZZZZ, 0,0 HEM MUFM m - ^- / • - jV/Z/� � rm 2 1 rz i m i a I rz�m • - -- • HEM ® - • • Oma/✓����.VZi-n i m - -- - • • HEM o - - nmiiMYvzzzi. o =HEM En UEM��qzlzzz HEM m - - om91IMNR;021 m - - HEMI 3.cl! 5.51 6.11 3:11 3.q1 5S q 8 q.8 q.4 2q.0 « PROVIDE LOCK CLIP ON CIRCUIT BREAKER ** EXTEND VIA GONTAGTOR "A" PROVIDE 3/4" FIRE TREATED PLYWOOD BACKBOARD, 4' HIGH AND 8'-0" LONG, MOUNTED 7'-4"" AFF FOR TELEPHONE, AUDIO DATA AND SECURITY SERVICE TERMINATION. WHERE DATA GABLES COME BACK TO TERMINATION BOARD, 6.G. PROVIDE PORT PATCH PANEL TO NETWORK HUB. FINAL CONNECTIONS BY TENANT'S DATA CONTRACTOR. I 18" L_ QUAD 1.6. OUTLET r--- ---r— --_ —�_ CIRCUIT RA -6----L, L �I I —I II 1 ON OUTLINE OF SECURITY JUNCTION BOX OUTLINE OF SECURITY PANEL BY TENANT'S CONTRACTOR OUTLINE OF TELEPHONE PANEL GIR.'.UIT RA -20 OUTLINE OF AUDIO EQUIPMENT RACK BY TENANT'S CONTRACTOR QUAD I.G. OUTLET CIRCUIT RA -10 NETWORK HUB AND PATCH PANEL PRODDED BY 6.G. MOUNT SOLID DIRECTLY TO PLYWOOD ELEVATION - AUDIO/TELE/SEGUR I T'i' EGU I P . 50ALE:1/4"=1'-0" ►i m " ... ARCHITECTS I NC 3801 5 CAPITAL OF TEXA5 HAY 5U I TE 330 AU5T I N TX 78704 TEL: 512.g12.7g94 FAX: 512.g12.7gci5 DON PENN CONSULTING ENGINEER 360 HIGHWAY 314 SUITE 101 GRAPEVINE, TEXAS 70061 817-410.2060 FAX 811-201.8411 'JUL 12 20'04 _ Ln ►i m " ... ARCHITECTS I NC 3801 5 CAPITAL OF TEXA5 HAY 5U I TE 330 AU5T I N TX 78704 TEL: 512.g12.7g94 FAX: 512.g12.7gci5 DON PENN CONSULTING ENGINEER 360 HIGHWAY 314 SUITE 101 GRAPEVINE, TEXAS 70061 817-410.2060 FAX 811-201.8411 'JUL 12 20'04 06.50.04 PERMIT, L.L. REVIEW 4 BID DATE 155UED FOR 0 minis ne �o CLAY TERRAGE GARMEL, IN 5FAGE #BI6 PANEL 5GHEDULEC- DETAIL5 MAMA #4084 E-3 FINL STORE #108 I. 5EGTION 16010 - BA51C ELEGTRIGAL REQUIREMENTS A. THE WORK INCLUDES FURNISHING AND INSTALLING THE MATERIAL, EQUIPMENT AND SYSTEMS COMPLETE AS SPECIFIED AND/OR INDIGATED ON THE DRAWIN65. THE ELECTRICAL INSTALLATIONS, WHEN FINISHED, 54ALL BE COMPLETE AND COORDINATED AND READY FOR 5AT15FAGTORY SERVIGE. B. ALL WORK UNDER THI5 CONTRACT SHALL BE DONE IN 5TRIGT AGGORDANGE WITH ALL APPLIGABLE MUNIGIPAL, STATE, BOGA AND LOCAL ELEGTRIGAL GODE5 THAT 60VERN EACH PARTICULAR TRADE AND THE 2002 NATIONAL ELEGTRIGAL CODE. G. THE GONTRAGTOR SHALL MAKE APPLICATION AND PAY ALL GHAR6ES FOR ALL NECESSARY PERMITS, LICENSES AND INSPECTIONS AS REQUIRED UNDER THE ABOVE CODES. UPON COMPLETION OF THE WORK, THE CUSTOMARY GERTIFIGATION5 OF APPROVAL SHALL BE FURNISHED. D. NO MATERIALS OR EQUIPMENT SHALL BE USED IN THE WORK UNTIL APPROVED. ALL MATERIALS SHALL BE U.L. LISTED. E. THE CONTRACTOR SHALL EXAMINE ALL DRAWIN65 AND SPECIFICATIONS AND SHALL INSPECT THE EXISTIN6 CONDITIONS OF THE SITE. FAILURE TO COMPLY WITH THI5 REQUIREMENT WILL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR COMPLYING WITH THE CONTRACT DOCUMENTS. F. THE DRAWIN65 INDICATE THE 6ENERAL_ ARRANGEMENT OF THE ELEGTRIGAL INSTALLATIONS. DETAILS OF PROPOSED DEPARTURES DUE TO ACTUAL FIELD CONDITIONS OR OTHER CAUSES SHALL BE 5UIBMI I I FOR APPROVAL PRIOR TO INSTALLATION. REWORK OF COMPLETED ITEMS DUE TO IMPROPER FIELD COORDINATION SHALL BE AT THE CONTRACTOR'S EXPENSE. 6. PROVIDE SUFFICIENT AGGE55 AND CLEARANCE FOR ALL ITEMS OF EQUIPMENT REQUIRING SERVIGIN6 AND MAINTENANCE. H. THE GONTRAGTOR SHALL PERFORM ALL NEGE55ARY GUTTING AND PATCHING AS REQUIRED TO COMPLETE THE INSTALLATIONS. PATCHING OF WALL5, FLOORS, GEILIN65, ETC. SHALL MATCH THE ADJACENT SURFACES. I. THE GONTRAGTOR SHALL PREPARE THREE (3) COPIES OF A RECORD AND INFORMATION BOOKLET. THE BOOKLET SHALL BE BOUND IN A THREE- RIN& LOOSE-LEAF BINDER AND INCLUDE ALL ITEMS OF ELECTRICAL EQUIPMENT. (I.E. PANELBOARDS, LI6HTIN6 FIX7URE5, LAMPS, ETGJ. J. UPON COMPLETION OF THE ELECTRICAL INSTALLATION, THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF PRINTS OF THE ELECTRICAL CONTRACT DRAWIN65 WHICH SHALL BE LEGIBLY MARKED IN RED TO SHOW ALL GHAN6E5 AND DEPARTURES OF THE INSTALLATIONS COMPARED WITH THE ORIGINAL DE516N. THEY SHALL BE SUITABLE FOR USE IN PREPARATION OF REGORD DRAWIN65. K. ALL NEW ELECTRICAL INSTALLATIONS SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR. THE ABOVE SHALL NOT IN ANY WAY VOID OR ABR06ATE EQUIPMENT MANUFACTURER'S GUARANTEE OR WARRANTY. CERTIFICATES OF GUARANTEE SHALL BE DELIVERED TO THE OWNER. L. ANY ELECTRICAL WORK WHICH WILL INTERFERE WITH THE NORMAL USE OF THE BUILDING IN ANY MANNER SHALL BE DONE AT SUCH TIME OR TIMES AS SHALL BE MUTUALLY AGREED UPON BETWEEN THE CONTRACTOR AND THE OWNER'S REPRESENTATIVE. M. ALL EXI5TIN5 ELECTRICAL 5Y5TEM5 IN OCGUPIED AREAS SHALL BE KEPT IN OPERATION DURING THE PR06RE55 OF WORK. TEMPORARY ELECTRICAL CONNECTIONS SHALL BE PROVIDED TO ALL SYSTEMS OR EQUIPMENT, WHERE NECESSARY TO MAINTAIN CONTINUOUS OPERATION UNTIL THE NEW 5Y5TEMS AND EQUIPMENT ARE READY FOR OPERATION. N. WHEN THE WORK SPECIFIED HEREUNDER CONNECTS TO ANY EXISTIN6 CONDUIT, WIRING OR OTHER EQUIPMENT, THE CONTRACTOR SHALL PERFORM ALL NEGE55ARY ALTERATIONS, GUTTING AND FITTING OF THE EX15TINEY WORK AS MAY BE NECESSARY OR REQUIRED TO MAKE SATISFACTORY CONNEGTION5 BETWEEN THE NEW AND EXISTING WORK AND SHALL LEAVE COMPLETED WORK IN A FINISHED AND WORKMANLIKE CONDITION, TO THE ENTIRE 5AT15FACTION OF THE ENGINEER O. ALL REMOVAL WORK SHALL BE PREFORMED IN A NEAT AND WORKMANLIKE MANNER AND SHALL BE EXECUTED WITH THE LEAST P0551E LE DISTURBANCE TO THE BUILDING. THE SGHEDULIN6 OF ALL REMOVAL WORK SHALL BE COORDINATED WITH OTHER TRADE5 AND WITH THE OPERATION OF THE OWNER'S FACILITY. WHERE REMOVAL WORK 15 PERFORMED, THE CONTRACTOR SHALL REPAIR ALL BUILDING SURFACES DAMAGED BY SUCH WORK. PROVIDE FINISHES TO MATCH EXISTING ADJACENT SURFACES. P. IN AREAS INDICATED TO BE RENOVATED, REMOVE THAT PORTION OF THE EXISTING El EGTRIGAL INSTALLATION TO COMPLETE THE NEW WORK AND ALL EQUIPMENT, WIRIN6, CONDUITS AND APPURTENANCES NOT REQUIRED IN THE COMPLETED INSTALLATION. ALL UNUSED GONDUIT AND WIRING EXPOSED AFTER DEMOLITION SHALL BE REMOVED BACK TO SOURCE (NEAREST POINT OF U5A&E). Q. WHERE ELEGTRIGAL SYSTEMS PA55 THROUGH THE RENOVATED AREAS TO SERVE OTHER PORTIONS OF THE PREMISES, THEY SHALL BE SUITABLY RELOCATED AND THE SYSTEM RESTORED TO NORMAL OPERATION. ANY OUTA6E5 IN SYSTEMS SHALL BE COORDINATED WITH THE OWNER'S REPRESENTATIVE. WHERE DURATION OF PROPOSED OUTA6E5 CANNOT BE TOLERATED BY THE OWNER, PROVIDE TEMPORARY GONNEGTION AS REQUIRED TO MAINTAIN SERVICE WITH THE MINIMUM DISRUPTION POSSIBLE. R. MARK AND PERMANENTLY IDENTIFY ALL 5WTCHE5, CONTROLS, PANELBOARDS, TERMINAL BOARDS AND OTHER EQUIPMENT IN AGGORDANGE WITH THE PROJECT NOMENCLATURE. INDENTIFIGATION PLATES SHALL BE LAMINATED PLASTIC, BLACK AND WHITE ENGRAVED LETTERS. LETTERING SHALL BE 3/8" HI&H. ATTACH PLATES WITH CHROME PLATED OR 316 STAINLE55 STEEL 5GREWS APPROVED FOR THE PURPOSE. S. GONTRAGTOR SHALL COORDINATE EXAGT PROTECTION, PROVISION REQUIRED, WIRE SIZE, CONDUIT, ETC. WITH MECHANICAL CONTRACTOR AND SHOP DRAWIN65 OF ALL MEGHANIGAL EQUIPMENT PRIOR TO ROUGH -IN. CONTRACTOR SHALL NOTIFY EN6INEER OF ANY DISGREPANGIES BETWEEN THE ELECTRICAL FLOOR PLANS AND MECHANICAL SHOP DRAWIN65. 2. SECTION 16050 - BA51G ELEGTRIGAL MATERIALS 4 METHODS A. CONDUIT 8 BOXES: (1) INSTALL ALL WIRING IN CONDUIT (EXCEPT AS OTHERWISE INDICATED SEE WIRES 4 GABLE) AND PROVIDE EMPTY GONDUIT FOR 5PEGIAL SYSTEMS DESCRIBED ELSEWHERE. MINIMUM CONDUIT SIZE SHALL BE 3/40. INSTALL ALL CONDUIT CONGEALED UNLE55 OTHMH15E INDIGATED. SUPPORT ALL CONDUIT 50 THAT STRAIN 15 NOT TRANSMITTED TO OUTLET BOXES AND PULL BOXES, ETC. SUPPORTS TO BE SUFFICIENTLY RI61D TO PREVENT DISTORTION OF CONDUITS DURING WIRE PULLIN6. (2) PROVIDE ELECTRICAL METALLIC TUBING (EMT) FOR GONGEALED WORK ABOVE 51,15PENDED GEILIN65 AND WITHIN INTERIOR PARTITIONS. PROVIDE FLEXIBLE METAL CONDUIT (GREENFIELD) IN SHORT LEN&TH5 FOR THE CONNECTION OF RECESSED L1644TIN& FIXTURES, MOTORS, AND ANY VIBRATING EQUIPMENT. FLEXIBLE GONDUIT MAY NOT BE USED IN INTERIOR DRYWALL PARTITIONS WHERE HORIZONTAL RUNS OGGUR. PROVIDE FULL 51ZE EQUIPMENT 6ROUND WIRE WHERE LEN&TH5 EXCEED SIX (b) FEET. ALUMINUM GONDUIT 15 PROHIBITED. (3) ALL OUTLET, SWITCH AND JUNCTION BOXES, ETC., SHALL BE SHERARDIZED OR GALVANIZED STAMPED STEEL AS MANUFACTURED BY STEEL GITY, RAGO, APPLETON, OR GENERAL ELECTRIC. PROVIDE BOX AT EACH OUTLET, SWITGH, ETC. ALL BOXES SHALL BE SIZED PER THE NEC OF A TYPE SUITABLE FOR THE DUTY INTENDED, SUPPLIED WITH APPROPRIATE RIN65. ELEGTRIGAL SPEG I F I GAT) ONS (4) JUNCTION AND PULL 5OXE5 SHALL BE FURNISHED AND INSTALLED AS SHOWN OR WHERE REQUIRED TO FACILITATE PULLING OF WIRES OR GABLES. 5UCH 5OXE5 SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS. ALL 5OXE5 FOR CONGEALED WORK SHALL BE CONSTRUCTED OF #I2 6AU6E U55 GALVANIZED SHEET STEEL MINIMUM, UNLESS OTHERWISE SPECIFIED OR INDICATED AND PROVIDED WITH MOUNTING BRACKETS AND FLAT SGREW COVERS, 5EGURED IN P051TION BY ROUND HEAD 5RA55 OR 5TAINLE55 STEEL 300 GRADE MACHINE SCREWS. (5) ALL CONDUIT SHALL BE CONGEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN 5TRAI6HT LINES PARALLEL WITH OR AT RIGHT AN&LE5 TO GOLUMN LINES OR BEAMS AND SEPARATED AT LEAST TWELVE INCHES FROM WATER LINES. (6) ALL CONDUITS ARE TO BE RUN T16HT TO DECK ABOVE. B. WIRES 4 GABLE: (1) BUILDING WIRE, UNLE55 OTHERWISE INDICATED, SHALL BE 600 VOLT, TYPE THWN OR THHN INSULATION FOR INTERIOR USE. CONDUCTORS SHALL BE SOFT DRAWN COPPER OF NOT LESS THAN clb% CONDUCTIVITY. NO ROMEX OR AG (BX) GABLES PERMITTED. (2) NO WIRE SMALLER THAN NO. (12) AWS SHALL BE USED UNLE55 OTHERWISE INDICATED. GONDUGTOR5 SHALL BE CONTINUOUS FROM OUTLET TO OUTLET AND FROM TERMINAL BOARD TO POINT OF FINAL CONNECTION, AND NO SPLICE SHALL BE MADE EXCEPT WITHIN OUTLET OR JUNCTION 5OXE5. ALL GONDUGTOR5 SHALL BE OF THE 51ZE-5 AS INDICATED. ALL WIRES NO. E16HT (8) AW6 AND LARGER SHALL BE STRANDED. THE CONTRACTOR SHALL MAKE WIRING GONNEGTIONS OF ALL ELECTRICAL EQUIPMENT REQUIRING El EGTRIGAL SERVICE. WIRES AND GABLES SHALL BE AS MANUFACTURED BY PLASTIC WIRE 4 GABLE CORPORATION, OKONITE COMPANY, GENERAL El ECTRIG, OR EQUIVALENT. (3) ALL WIRING SHALL BE COLOR CODED, PER LANDLORD CRITERIA. (4) WIRIN6 FOR 6ENERAL 120 VOLT BRANCH GIRGUIT5 SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED OR REQUIRED TO LIMIT VOLTAGE DROP TO 3%-. HOMERUN LENGTH CIRCUIT LENGTH 4 WIRE 51ZE i WIRE 51ZE 01-60' #12 0'-100'#12 61'-100' #10 101' 8 UP #10 G. D15GONNECT'S: (1) FURNISH AND INSTALL SAFETY SWITCHES WHERE INDICATED AND AS REQUIRED FOR MOTOR OUTLETS OR OTHER EQUIPMENT. SWITCHES SHALL BE OF SIZE, NUMBER OF POI E5 AND FUSED OR NON-FUSED, AS REQUIRED FOR JOB CONDITIONS AND THE NATIONAL ELECTRICAL CODE. (2) ALL SAFETY SWITGHE5 SHALL BE NEMA I ENGL05L RE TYPE 'HD" QUIGK-MAKE, QUICK -BREAK, AND HAVE INTERLOGKIN6 COVER WITH HANDLE THAT MAY EITHER BE FRONT OR 51DE OPERATING WITH A PADLOGKIN& PROVISION, AS MANUFAGTGRED BY SQUARE "D" OR APPROVED EQUAL. D. WIRING DEVICES: (1) THE FOLLOWING WIRING DEVICES SHALL BE FURNISHED AND INSTALLED WHERE GALLED FOR ON THE DRAWIN65. MISCELLANEOUS ITEMS NOT INCLUDED BELOW SHALL BE UNDERWRITERS' LABORATORIES STANDARD GONFORMIN6 TO THE NEG. ALL DEVICES SHALL BE OF THE SAME MANUFACTURER. DEVICES SHALL BE ARROW HART, PA55 4 SEYMOUR, LEVITON, OR HUBBELL AND EQUAL TO THE FOLLOWING ARROW HART NUMBER5: WALL SWITCHES: T066LE 5WITGHE5 SHALL BE OF THE 51LENT MEGHANIGAL TYPE RATED 20 AMPERE, 120 VOLT A.G. 51N6LE POLE SWITCHES SHALL BE ARROW IggIW FOR 20 AMPERES. THREE-WAY SWITCH SHALL BE OF THE SAME MANUFAGTURER AND GRADE. ALL DEVICES SHALL BE WHITE. REGEPTAGLE5: RECEPTACLES FOR WALL OUTLETS SHALL BE RATED 20 AMPERE, 125 VOLTS, DUPLEX, THREE -WIRE WITH THIRD POLE &ROUNDED. OUTLETS SHALL BE ARROW HART 5362 FOR 20 AMPERE. &FGI SHALL BE #6F5542 RATED FOR 20 AMPERE. ALL RECEPTACLES MOUNTED IN THE SALES AREA SHALL BE BLACK IN COLOR, ALL REGEPTAGLE5 MOUNTED IN REMAINDER OF THE STORE SHALL BE WHITE IN COLOR. DEVICE PLATES: A DEVICE PLATE SHALL BE PROVIDED FOR EACH OUTLET REQUIRING ONE. ALL PLATES SHALL BE MANUFACTURED BY PASS t SEYMOUR. WHERE TWO OR MORE DEVIGE5 ARE GROUP MOUNTED, PROVIDE A MULTI-6AN6 OUTLET BOX AND A55OGIATED GOVERPLATE. ALL GOVERPLATE5 MOUNTED IN THE SALES AREA SHALL BE BLACK IN COLOR, ALL GOVERPLATES MOUNTED IN REMAINDER OF THE STORE SHALL BE WHITE IN COLOR. MOUNTING HEIGHT AND LOCATION OF ALL DEVIGE5 SHALL BE CL05ELY COORDINATED WITH MANN 4 MANN ARCHITECTS AND THE TENANT REPRESENTATIVE PRIOR TO ROUGH -IN. E. &ROUNDIN&: (1) ALL ELECTRICAL SYSTEM 6ROUND5 SHALL BE PROVIDED A5 INDICATED ON THE DRAWIN65, MENTIONED HEREIN AND/OR AS REQUIRED BY THE NATIONAL ELECTRICAL CODE. THE FOLLOWIN6 SHALL BE 50LIDLY &ROUNDED: (A) CONDUIT SYSTEM AND OUTLET BOXES (0) LI&HTIN6 FIXTURES (C) PANELBOARD5 (D) ELECTRIC HEATING EQUIPMENT (EJ TRANSFORMERS (F) MOTOR FRA1"IE5 (6) WIRING TROUSH AND PULLBOXES (H) FIRE ALARM SYSTEM 3. SECTION 16400 - SERVIGE 4 DISTRIBUTION A. ELECTRICAL SERVICE: (1) El EGTRIGAL SERVICE 15 NEW FROM THE LANDLORD ELEGTRIG SWITCHBOARD IN THE MALL ELECTRICAL ROOM. THE SERVICE VOLTAGE 15 INDICATED ON THE DRAWIN65. B. PANELBOARD5: (1) ALL PANELBOARD5 SHALL BE BALANCED TO WITHIN 10515 OF THE LOWEST PHASE AND A REPORT INDICATING AMPERAGE OF EACH PHASE SHALL BE SUBMITTED TO THE MALL OPERATIONS MANA6ER. (2) THE CIRCUIT NUMBERS USED ON DRANIN66 ARE FOR IDENTIFIGATION ONLY AND THE CIRCUIT NUMBER IN THE PANEL NEED NOT NEGE55ARILY CORRESPOND. EACH CIRCUIT IN THE PANELS, HOWEVER, SHALL BE AGGURATELY INDEXED AND TYPED AS SPECIFIED HEREIN. (3) THE PANELBOARD SHALL EMPLOY BOLT -ON BREAKERS OF AND NOT LE55 THAN 10,000 SYMMETRIGAL A.I.G. AT 120 OR 240 VOLTS. (4) ALL PANELBOARD INTERIORS SHALL BE FACTORY ASSEMBLED, COMPLETE WITH GIRGUIT BREAKERS AS SGEHEDULED ON THE DRAWIN65. INTERIORS SHALL BE DE516NED AND A55EMBLED SUCH THAT ANY INDIVIDUAL BREAKER CAN BE REPLACED WITHOUT D15TLIR51NCT ADJACENT UNITS OR WITHOUT REMOVING MAIN BUS, AND SHALL EMPLOY SEQUENCE BUSSIN6. MAIN BU55ES AND BACK PANS OF PANELBOARDS SHALL BE OF SUCH DESIGN THAT BRANCH CIRCUITS MAY BE GHANOED WITHOUT ADDITIONAL MACHINE, DRILLING, OR TAPPING. ALL GIRGUIT BREAKERS SHALL BE QUIGK-MAKE AND SHALL BE TRIPPING INDIGATIN6. PANELBOARD5 TO BE SQUARE "D" OR GENERAL ELECTRIC. (5) THE MAIN BUS SHALL BE MANUFACTURERS STANDARD GRADE ALUMINUM. MAIN BUS SHALL EXTEND THE ENTIRE LENGTH OF THE ENGLO5URE. (6) UNLE55 OTHERK15E NOTED ALL PANELBOARDS SHALL BE PROVIDED WITH A 50% GROUND BUS BAR. G. FU5E5: (1) FUSES FOR FEEDER CIRCUITS AND PANELBOARDS SHALL BE U.L. GLASS RKI FA5T-AGTIN6 TYPE. (2) FUSES FOR MOTOR OVERGURRENT AND TRANSFORMER PROTECTION SHALL BE DUAL ELEMENT. U.L. GLASS RKI TIME DELAY TYPE. FUSES SHALL BE OF A TRUE DUAL ELEMENT GONSTRUGTION, INGORPORATIN& A THERMAL OVERLOAD ELEMENT U51NS A 280 DEGREE F. MELTING POINT ALLOY. THE DE516N SHALL PROVIDE TIME -DELAY OF NOT LE55 THAN 10 5EGONDS AT 500% OF AMPERE RATING. THE INTERRUPTING RATIN& SHALL BE 200,00 AMPERE5 RM5 SYMMETRICAL. PEAK LET-THRU CURRENT AND ENERGY LET-THRU VALUES SHALL NOT EXCEED THE VALUES ESTABLISHED U.L. STANDARD5 FOR GLASS RKI FUSES. D. DRY TYPE TRANSFORMERS: (1) PROVIDE SELF COOLED, DRY TYPE TRANSFORMER OF KVA, PHASE AND VOLTAGE RATIN65 A5 INDICATED ON THE DRAWIN65. (2) TRANSFORMERS SHALL BE ENGL05ED IN A SUITABLE HOU51N6 ARRANGED FOR FOR CONDUIT ENTRANCE ON THE PRIMARY AND 5EGONDARY 51DE. GASES SHALL BE PROVIDED WITH ADEQUATE LOUVERED OPENIN65 TO ALLOW SUITABLE VENTILATION AND GOOLI N6. TRANSFORMER SHALL HAVE A GLA55 H (220 DE&REE5 G) INSULATION FOR GONTINUOU5 OPERATION AT RATED LOAD IN A 40 DEGREE G AMBIENT WITH A TEMPERATURE R15E NOT EXCEEDING 150 DE6REE G. (3) TRANSFORMER SHALL HAVE 2-1/2% FULL CAPACITY TAP5 BELOW AND ABOVE RATED PRIMARY VOLTA6E. TRANSFORMER SHALL HAVE A LEVEL NOT EXGEEDIN6 45 db BASED ON NEMA TEST PROCEDURES. (4) NEUTRALS OF TRANSFORMER SHALL BE 6ROUNDED IN AGGORDANGE WITH THE N.E.G.. IMMEDIATE GONNEGTIONS TO AND FROM TRANSFORMER SHALL BE THROUGH FLEXIBLE GONDUIT. E. GOMMUNIGATION5 SERVIGE: (1) THE CONTRACTOR SHALL PROVIDE AN OUTLET BOX AT EACH TELEPHONE LOCATION GON515TIN6 OF A SINGLE &ANG BOX 2-1/8" DEEP WITH RA15ED COVER. EXTEND 1/2" EMPTY CONDUIT FROM EACH OUTLET TO THE GEILIN6 SPACE AND EXTEND BACK TO TENANT'S TELEPHONE BAGKBOARD. TERMINATE CONDUIT NYLON BU5HIN& AND PULL5TRIN6. (2) WHERE GEILIN6 SPACES ARE USED AS A RETURN AIR PLENUM, THE GABLES INSTALLED BY THE OWNER FOR EACH COMMUNICATIONS SYSTEM! WILL BE TEFLON OR SIMILAR APPROVED LOW SMOKE DEN5ITY TYPE. 4. SECTION 16500 - L16HTIN& FIXTURES A. INSTALL A GOMPLETE LI&HTIN& FIXTURE FOR EACH LIGHTING FIXTURE SYMBOL SHOWN ON THE DRAWIN65, OF THE TYPE AND QUALITY DESCRIBED HEREIN. FIXTURES SHALL BE INSTALLED GOMPLETE WITH LAMPS OR THE WATTAGE INDIGATED, SOCKETS, HOU51N6, BALLAST (IF REQUIRED), SHADES, DIFFUS, SUPPORTS, ETC., AND WIRED FOR OPERATION. ALL LI6HTIN6 FIXTURES AND LAMPS WILL BE FURN15HED BY THE GENERAL CONTRACTOR AND INSTALLED BY THE ELECTRICAL CONTRACTOR. B. ALL FIXTURES SHALL BE WIRED FOR POLARIZED 5YSTEM WITH ONE WIRE IN EACH FIXTURE TO BE 015TINGTLY MARKED FOR ITS ENTIRE LEN6TH. WIRE SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS' LABORATORIES, ING. FIXTURE WIRING FOR FLUORESCENT FIXTURES AND BRANCH CIRCUIT WIRING IN FLUOR -50ENT FIXTURE CHANNELS SHALL BE TYPE THHN OR THW MO DE6REE5 G. RATED). ALL CHANNELS IN FLUORE56ENT L16HTIN6 FIXTURES SHALL BE APPROVED FOR THROU614 WIRING. TYPE AF WIRE SHALL ONLY BE USED FOR INTERIOR INGANDESGENT FIXTURE WIRIN6. G. EACH FIXTURE SHALL BE COMPLETELY EQUIPPED WITH LAMPS OF THE SIZE, TYPE, WATTAGE AND SHAPE INDICATED AND SPECIFIED. ALL LAMPS SHALL BE MANUFACTURED BY THE GENERAL ELECTRIC GO., WI=5TIN6HOUSE MFG. CO., SYLVANIA, OR APPROVED EQUAL, OF STANDARD 5GHEDULE MAKE. LUMEN OUTPUT AND LIFE OF LAMPS SHALL BE IN ALL RESPECTS EQUIVALENT TO THOSE SPECIFIED. ALL LAMPS SHALL BE PROPER VOLTAGE FOR THE BUILDING. EXACT VOLTAGE SHALL BE CHECKED BEFORE ORDERING LAMPS. D. FLUORESCENT LAMPS SHALL BE GENERAL ELECTRIC RAPID START ENER6Y SAVER 32 WATT F32T8/5P35/2g00 LUMEN5, UNLESS OTHERWISE SPEGIFIED. E. FLUORESCENT FIXTURES SHALL GENERALLY HAVE TWO LAMP BALLASTS. ALL BALLASTS SHALL BE ELEGTRONIG SOLID STATE TYPE GBM AND UL CERTIFIED, HIGH POWER FACTOR (XIO%) TYPE WITH SOUND RATIN& "A". ALL ELECTRONIC BALLAST5 SHALL BE DISGRETE WITH INSTANT START AND PROVIDE PARALLEL OPERATION OF LAMPS. EAGH BALLAST SHALL BE INTERNALLY PROTECTED WITH A RE5ETTABLE THERMAL PROTECTOR TO CONFORM TO UL REQUIREMENTS FOR TYPE "P" BALLASTS. BALLASTS SHALL BE MAGNETEK TRIAD OR APPROVED EQUAL OF ADVANCE, VALMONT, OR MOTOROLA. BALLA5T5 SHALL NOT EXCEED qO DEGREES G. GA5E TEMPERATURE IN CONTINUOUS OPERATION AND FIXTURE MANUFACTURER SHALL FURNISH TESTS REPORTS GONFIRMIN& SAME FOR FIXTURE INSTALLATIONS MATCHING JOB GONDITION5. BALLAST SHALL MEET ALL APPLICABLE ANSI AND IEE STANDARDS RE&ARDIN& TOTAL HARMONIC D15TORTION (THD). BALLAST THD SHALL NOT EXCEED 20%. F. AT THE LOCATIONS OF OUTLETS INDICATED ON THE VARIOUS DRAWIN65, THE TYPE OF FIXTURE REQUIRED 15 DESIGNATED BY A TYPE LETTER. ALL FIXTURES SHALL BE FURN15HED IN THE QUANTITIE5, 51ZE5 AND TYPES AS INDICATED ON THE DRAWINGS. 6. REGE55ED FLUORESCENT FIXTURES IN GEILIN&5 MAY NOT BE SUPPORTED FROM THE SUSPENDED GEILIN6. BOXES AND FIXTURE SUPPORTS SHALL BE FASTENED SECURELY TO GONGRETE SLAB, BAR J015T OR STRUCTURE EXCEPT AS NOTED. WHERE FIXTURES ARE SURFACE MOUNTED, NEAT HOLES SHALL BE GUT IN THE HUNG GEILIN66 A5 REQUIRED FOR THE FIXTURE SUPPORTS. ALL SUPPORT HAN6ER5, CHANNELS, BOLTS, ETC., SHALL BE GALVANIZED OR 6ALV-KROM. H. UNDER THIS SEGTION, PROVIDE ADEQUATE SUPPORTS FOR ALL FIXTURES SEPARATE FROM THE SUSPENDED GEILIN6 SYSTEM. CONTRACTOR SHALL FURNISH AND INSTALL ALL NEGE55ARY AGGE55ORIE5 A5 REQUIRED, TO SUPPORT THE FIXTURES. PROVIDE A MINIMUM OF TWO (2) 6ALVANI7ED STEEL #12 6AUOE HANGER WIRES ON ALL REGE55ED FIXTURES. I. PROVIDE ALL REGE55ED LIGHT FIXTURES WITH A GYPSUM BOARD ENGL05LRE AS REQUIRED BY THE FIRE MARSHALL, TO MAINTAIN A ONE HOUR RATIN& OF THE GEILIN6. J. H.I.D. BALLASTS SHALL BE GORE AND COIL TYPE SUITABLE FOR THE CIRCUIT VOLTA&E5 INDICATED ON THE DRAWIN65. K. PROVIDE ADDITIONAL EXIT LIGHTS AND EMER6ENGY BATTERY PACKS WITH DUAL HEADS AS NEEDED TO MEET FIRE MAR5HAL5 WALK THROU614 AND ACCEPTANCE. I ARCHITECTS I NC 5501 5 CAPITAL OF 7EXA5 HWY 5U 1 TE 330 AU571 N TX 78704 TEL: 512.g12.7gq4 FAX: 512.g12.7gq5 DON PENN CONSULTING ENGINEER 300 HIGHWAY 804 SUITE 101 GRAPEVINE, TEXAS 78061 SR-4104MM FAX 811-201-8411 'JUL12 2004 06.30.04 PERMIT, L.L. REVIEW 4 BID DATE 155UED FOR f inns ne o C�Q7t�i CLAY TERRACE GARMEL, IN 5PAGE #516 ELEGTRIGAL SPEGIFIGATIONS M&MA #4084 E-4 9c 5TOK #'105 MECHANICAL LEGEND .mov MOTOR OPERATED DAMPER FLEX I BLE GONNEGT I ON SOUND LINED DUGTWORK Ej TURNING VANES i x SUPPLY DUCT DOWN SUPPLY DUCT UP i RETURN DUGT DOWN RETURN DUGT UP i EXHAUST DUGT DOWN EXHAUST DUGT UP AIRTITE FITTING WITH INTEGRAL VOLUME DAMPER FLEXIBLE DUGT ® SUPPLY AIR z RETURN AIR ® EXHAUST AIR -il* DIREGTION OF AIR FLOW 8 THERM05TAT 5D SMOKE DETEGTOR lO DRAWING NOTE DUGT HEATER AND FILTER RAGK. PROVIDE FULL SIZE DRAIN I" UNDERGUT DOOR SANITARY PIPE -----5 VENT PIPE 5----si GOLD WATER PIPE -� HOT WATER PIPE -�-5 GONDEN5ATE DRAIN PIPE 4--- s -� REFRIGERANT 5UGTION �-- L --5 REFRIGERANT L I QU I D C—� PIPE DOWN O—� PIPE UP FINL 5TOR5 #l08 GLEANOUT GO. O r BALL VALVE 4 GONTRAGTOR SHALL PROVIDE OFFSETS (MAXIMUM 30 DEGREE UNION ANGLE STOP VALVE A.H.U. AIR HANDLING UNIT G.F.M. GUBIG FEET PER MINUTE TYP. TYPIGAL C -7 N RAL. lvALL- NOTr=5: (DCOORD I NATE D 15GREPANG I E5 BETWEEN DOCUMENTS AND FIELD GONDITION5 WITH THE TENANT OR H15 AUTHORIZED AGENT. GOORD I NATE THE EXTENSION, MOD I F I GATI ON5, F I NAL GONNEGT I ON AND TE5TIN6 OF ALL UTILITIES OR INTERFAGED SYSTEMS WITH THE LANDLORDS FIELD REPRESENTATIVE. O2 ALL TEMPERATURE CONTROL, FIRE ALARM GOMPONENT5, EQUIPMENT NAMEPLATES, LABELS OR COLOR CODED GOMPONENT5 SHALL BE MASKED DURING PAINTING TO PREVENT DAMAGE FROM OVER5PRAY OR OB5GURIN6 IDENTIFICATION. O VERIFY THE SIZE, LOGATI ON AND GOND I TI ON OF THE EX 15TI N6 PI PING, TOILET EXHAUST, ENERGY BU I LD I N6 MANAGEMENT SYSTEM CONNECTION POINTS, AND OUTSIDE AND RELIEF AIR ROOF OPENING5 AND HOODS. REPLAGE EXI5TIN6 GOMPONENT5 IF THEY ARE INADEQUATE FOR THE NEW REQUIREMENTS OR INOPERABLE. A. INDIGATE THE MINIMUM 51ZE REQUIRED TO UTILIZE EXI5TIN6 TAPS OR SPECIFY THAT NEW GONNEGT5 ARE REQU I RED. B. UTILIZE EXISTING ROOF OPENING5 FOR NEW INTAKES AND OR RELIEF HOODS IF POSSIBLE. O4 THE TENANT 15 RESPONS I BLE FOR PROV I D I N6 A STAND ALONE TEMPERATURE GONTROL 5Y5TEM UTILIZING LANDLORD 5PEGIFIED COMPONENTS. THIS 5Y5TEM SHALL INTERFAGE WITH THE LANDLORD BUILDING MANAGEMENT SYSTEM. A. ONLY LANDLORD 5PEGIFIED TEMPERATURE CONTROLS SHALL BE UTILIZED FOR THI5 PROJEGT. NO SUBSTITUTIONS ARE PERMISSIBLE. THE LANDLORD DE516NATED GONTRAGTOR SHALL PERFORM F I NAL WIRING GONNEGTION5 AND PROGRAMMING OF CONTROLS. B. POWER FOR TEMPERATURE GONTROL5 SHALL BE PROVIDED FROM A DED I GATED G I RGU I T WHERE POWER 15 PROVIDED FROM A 5OURGE OTHER THEN THE AHU G I RGU I T. THE G I RGU I T MUST BE GROUNDED AND THE BREAKER LOCKED TO AVOID POWER SHUT OFF UNINTENDED. GONTROL5. G. THE TENANT SHALL COMPLETE THE INTERFACE AND THE OPERATION SHALL BE 5UGGE55FULLY DEMONSTRATED FOR THE LANDLORD FIELD REPRE5ENATIVE PRIOR TO OGGUPANGY. O FILTER MEDIA SHALL BE UT I L I ZED TO PROTEGT ALL RETURN DUGT5 AND OPENINGS DURING GON5TRUGTION. O6 PIPE SLEEVES SHALL EXTEND A MINIMUM OF 4" ABOVE THE FIN 15HED FLOOR. SLEEVES SHALL BE FLASHED INTO THE WATERPROOF FLOORING MEMBRANE PER THE MEMBRANE MANUFACTURER'S REGOMMENDATION5. O FIXTURES SHALL BE FLASHED INTO THE WATERPROOF MEMBRANE PER THE MEMBRANE MANUFACTURER'S RECOMMENDATIONS. O8 THE TENANT SHALL DIRECTLY EMPLOY THE LANDLORD DESIGNATED CONTRACTOR TO PERFORM ALL SPRINKLER MODIFICATIONS. SYSTEM MODIFICATIONS SHALL BE SCHEDULED IN ADVANCE WITH THE LANDLORD'S FIELD REPRESENTATIVE. THE SPRINKLER SYSTEM SHALL BE FULLY CHARGED AND OPERATIONAL WHEN THE CONTRACTOR IS OFF THE SITE. CONCRETE ANCHOR TO STRUCTURE ABOVE CONCRETE IN5ERT VIBRATION ISOLA (TYP I GAL) GOOLI N6 GOIL — FILTER RACK WITH 2'L T - T DISPOSABLE FILTER 4 HINGED 6A5KETED AGGE55 DOOR CLAMP ROD TO TOP CORD OF JOI5T/BEAM 5TRUGTURAL JOI5T/ BEAM (TYP.) ANCHOR TO STRUCTURE ABOVE ALL THREAD ROD (TYP) AN FLEXIBLE DUCT CONNECTION INSULATED DX PIPING TO ROOF MOUNTED GONDENSIN6 UNIT. VERIFY EXACT LOGATIO ON ROOF WITH MALL FIELD REPRE5ENTATI VE. FILTER AGGE55 DOOR I �— KINDORF SUPPORT (TYP) FULL 51ZE CONDENSATE DRAIN WITH 3" DEEP SEAL TRAP. FULL 51ZE DRAIN PAN CONNECT TO STORM BELOW A/C UNIT EXTEND WATER MAIN WITH GHEGK VALVE MIN. 6" BEYOND UNIT ON COIL AGGE55 PANEL ALL SIDES "PRIMARY" AHU UN 1 T 1IOUN71 N6 i7E7A L NO SCALE O PROVIDE STRUCTURAL FARMING PLAN FOR NEW EQUIPMENT MOUNTING AND NEW OPENING REINFORCEMENTS. SPECIFY THE SIZE AND SHAPE OF THE STRUCTURAL REINFOREMENTS. 10 GENERAL REQUIREMENTS. A. THE LANDLORDS DE51ONATED GONTRAGTOR SHALL PERFORM ALL ROOF I N6. B. ROOF I N6 ADJACENT TO NEW EQUIPMENT SHALL BE MODIFIED AS RQUIRED TO PROVIDE THE PROPER SLOPE FOR DRAINAGE. G. ALL EXHAUST AND PLUMBING VENTS MUST BE A MINIMUM OF TWENTY FEET FROM ANY OUTSIDE AIR INTAKE. D. ROOF MOUNTED EQUIPMENT SHALL BE LOCATED NO CLOSER THAN 5'-0" AWAY FROM THE VERTIGAL PLANE OF THE 5PAGE DEMI51N6 WALL5. E. FACTORY FABRICATED ROOF GURB5 SHALL BE UTILIZED. ALL CURBS SHALL EXTEND A MINIMUM OF TWELVE INGHE5 ABOVE THE HIGH POINT OF THE ROOFING MATERIAL. FIELD FABRI GATED WOOD BU I LDT-UP CURBS, WOOD SLEEPERS AND PITGH POCKETS ARE NOT ACCEPTABLE. F. FAGTORY FABRIGATED HOODS OR PENTHOUSE AND MATGHING GURB5 SHALL BE UTILIZED FOR ALL INTAKE -5 OR EXHAUSTS. 6005ENEGK5 ARE NOT AGGEPTABLE. 6. LABEL ROOF MOUNTED EQUIPMENT WITH THE TENANT NAME, 5PAGE NUMBER AND EQUIPMENT IDENTIFICATION (I.E. EF -I, MUA-I, RTU -I). H. GONF I RM EQUIPMENT LOCATIONS AND SCHEDULE THE INSTALLATION OF ROOF MOUNTED EQUIPMENT WITH THE LANDLORDS FIELD REPRESENTATIVE PRIOR TO THE START OF GON5TRUGTION. I I 5GHEDULE BALANG I N6 WITH THE LANDLORDS FIELD REPRESENTATIVE. PROVIDE A COPY OF THE APPROVED TEST AND BALANCE REPORT TO THE LANDLORD. 12 VERIFY THE SIZE OF THE EXI5TIN6 DOMESTIC WATER SERVIGE GONNEGTION. THE TENANT 15 RESPONSIBLE FOR UPORADIN6 THE EXI5TIN6 5ERVIGE IF IT 15 INADEQUATE FOR THE NEW REQUIREMENTS. COORDINATE THE NEW SERVICE GONNEGTI ON POINT WITH THE LANDLORD FIELD REPRESENTATIVE. 13 GONFIRM SMOKE CONTROL REQUIREMENTS WITH LOGAL AUTHORITIES AND AMEND DOGUMENT5 AGGORD I NGLY. N MF.GHAN I GAL FLOOR PLAN SCALE: I/8"= I' -O" NOT 1 CE TO C0N7RAC70R5 : I ALL CONTRACTORS PRIOR TO BID SUBMISSION PROGE55 5HALL VI51T PROPOSED WORK 51TE AND FIELD VERIFY ALL EXI5TIN6 CONDITIONS. ANY GONDITION5 THAT DIFFERS FROM THAT SHOWN ON THI5 PLAN SHALL BE REPORTED TO ARGHITEGT/EN(5INEER 50 THAT NEW AND REVISED BID DRAHIN66 OR INFORMATION MAY BE ISSUED. MODIFIGATION5 TO 5GOPE OF WORK WHIGH RESULT5 FROM GONTRAGTOR5 NEGLECT TO VISIT THE 51TE PRIOR TO SUBMITTING BID, SHALL BE THE GONTRAGTOR5 SOLE RE5PON51BILITY. NOTA I. FOR ADDITIONAL DETAIL, SPECIFICATIONS AND MALL REQUIREMENTS, REFER TO MALL SHEETS MEP -I, MEP -2 AND MEP -3. CEENERAL NOTES 1) ALL NEW AIR DUCTS SHALL BE MOUNTED TIGHT TO THE UNDERSIDE OF THE STRUCTURE. 2) THE GONTRAGTOR SHALL VERIFY ALL EX15TINO FIELD CONDITIONS AND ADJUST NEW WORK A5 REQD. ALL REWORKING OF 5Y5TEMS SHALL BE DONE WITH NO GHANOE ORDERS. ALL DUGT5 MUST BE MAI NTA I NED ABOVE GL65. AND TIGHT TO 5TRUGTURE TO MAINTAIN ARGHITEGTURAL DE51 ON I NTE ORI TY. 3) ALL GEILIN6 DIFFUSERS IN THE SALES AREA SHALL BE GENTERED BETWEEN LIGHT FIXTURES AND MAINTAIN A 5YMMETRIGAL LAYOUT. 4) ALL SUPPLY AIR DIFFUSERS NOT MOUNTED IN GE I L I N65 SHALL BE MOUNTED HI 6H AS POSS I BLE. ALL GEILIN6 MOUNTED DIFFUSERS SHALL BE MOUNTED AT F I N I5HED GEILIN6 ELEVATION. 5) ALL DOUBLE DEFLEGTION SUPPLY AIR RE615TER5 SHALL HAVE DEFLEGTOR BLADES SET TO THROW AIR DOWNWARD AND IN A EQUAL HORIZONTAL PATTERN. 6) ALL SUPPLY AIR DEVICES MOUNTED IN GE I L I NG5 SHALL BE PAINTED INTERNAL AND EXTERNAL TO MATCH THE GEILIN6 5URFAGE. 7) ALL INSIDES OF 5UPPLLY AND RETURN AIR DUGT5 (MINIMUM 36" OF OPENING OR TO FIRST ELBOW, WHIGH EVER 15 GREATER) SHALL BE PAINTED FLAT BLAGK TO AVOID GLARE OF INTERIOR SHEET METAL 5URFAGE5. 8) AGGE55 TO ROOF FOR ROOF MOUNTED EQUIPMENT SHALL BE V I A MALL ROOF HATCH AND LADDER. LADDER/AGGE55 SHALL BE LOGKED AND GONTROLED BY THE MALL. FOR AGGE55, CONTRACTOR MUST GOORD I NATE WITH THE MALL. ORAA IN Cv NOTES O HORIZONTAL MOUNTED AHU WITH OX GOOLI N6 GOIL, ELEGTRIG DUGT HEATER AND FILTER RAGK. PROVIDE FULL SIZE DRAIN PAN UNDER UNIT AND M.O.D. ON OUTSIDE AIR DUGT. I NTERLOGK O.A. M.O.D. WITH UNIT AND NI GHT 5ET-13AGK GONTROL5. EXTEND GONDEN5ATE PIPING FROM AHU TO SERVICE SINK. PROVIDE 3" DEEP SEAL TRAP AT UNIT. INTERLOCK UNIT WITH OU51DE AIR PERMIT, L.L. REVIEW 4 BID DATE M.O.D. �7/S ne L:IVWWo{/{/Ul/U��il/i U!!(JIJL�nlhl�ill ull CLAY TERRACE CARMEL, IN 5PAGE #516 O2 FULL 51ZE OUTSIDE AIR DUGTWORK MOUNTED UP THRU 5TRUGTURE FINL 5TOR5 #l08 WITH M.O.D. BALANGIN6 DAMPER. (TYP) O SUPPLY AIR DUGTWORK MOUNTED TIGHT TO 5TRUGTURE. GONTRAGTOR SHALL PROVIDE OFFSETS (MAXIMUM 30 DEGREE ANGLE) TO MAINTAIN DUGTWORK HIGH AS POSSIBLE. O4 AI RTI TE F I TTI N6 WITH DAMPER AND ADHE51 VE 6A5KET. O5 SUPPLY AIR RE615TER MOUNTED IN BOTTOM OF DUGT. O6 SUPPLY AIR RE615TER MOUNTED ON 51DE OF DUGT OR AT EDGE OF GEILIN6 BULKHEAD. ALL DIFFUSER BLADES SHALL BE ADJUSTED TO PROVIDE EQUAL AIR DISTRIBUTION DOWN TO FLOOR. FINAL GOORDINATION/APPROVAL BY ARCHITECT (TYPIGAL). O RETURN AIR DUGT MOUNTED BELOW BAR J015T AND HIGH AS P0551 BLE. O8 SUPPLY AIR DIFFUSER WITH 12 "x 12" MODULE AND TRM PLASTER FRAME (TYP). O THERMOSTAT MOUNTED ON WALL *0" A.F.F. WITH LOGKABLE COVER. GOVER SHALL BE METAL AND PAINTED AS DIRECTED BY ARGHITEGT (TYPIGAL). I O BALANG I N6 DAMPER (TYP). II GEILIN6 MOUNTED EXHAUST FAN SUSPENDED FROM STRUCTURE. EXTEND DUGT UP THRU ROOF/6005ENEGK. 12 12"xl2" RETURN AIR GRILLE WITH FULL SIZE LINED ELBOW. PROVIDE 1/2"x 1/2" WIRE MESH 5GREEN ON DUGT OPENING. MOUNT PIS(' HARrvE OPENING A MINIMUM 12-6" A.F.F. 13 FLEXIBLE DUGT, MAXIMUM 5'-0" (TYP). 14 LINED RETURN AIR DUGT. PROVIDE A 1/2" x 1/2" WIRE MESH ON END OF DUGT/ELBOW TO KEEP OUT DEBRIS FROM GEILIN6 PLENUM. PAINT DUGT BLAGK ±60" TO AVOID GLARE. 15 THERM05TAT MOUNTED ON WALL/MILLWORK PANEL (TYPIGAL). I6 60"x24" TRANSFER AIR GRILLE MOUNTED IN WALL. PAINT TO MATGH ADJACENT SURFACE. MOUNT WITH 6RILLE5 BLADE UP TO AVOID L I6HT TRANSFER. MOUNT ON BOTH 51 DES OF WALL. 17 DUGT MOUNTED SMOKE DETEGTOR PROVIDE 12"xl2" AGGE55 DOOR FOR TUBE IN5PEGTION. SMOKE DETEGTOR WORK 15 BY THE LANDLORDS CONTRACTOR. 18 FULL 51 ZE CONDENSATE DRAIN LINE TO MOP SINK. IG WALL MOUNTED ELEGTRIG HEATER IN WALL t8" A.F.F. HEATER SHALL BE BERKO MODEL 5RA1012, 1.0 K.W., 120 VOLT/I PHASE. ® OPEN END RETURN AIR DUGTWORK WITH 1/2"xl/2" WIRE MESH SGREEN OVER OPEN END. 2 I REFR 16ERANT P I P I N6 EXTENDED UP TO ROOF MOUNTED GONDEN51 N6 UNIT. VERIFY EXAGT ROUTING IN THE FIELD. VERIFY MOUNTING LOCATION OF GONDEN5ING UNIT WITH SITE LANDLORD REPRESENATIVE. ® LOW LEAKAGE MOTOR OPERATED DAMPER (TYP. ALL AHU UNITS). SLIP IN ELEGTRIG DUGT HEATER. HEATER SHALL BE I NTERLOGKED WITH AHU-1. HEATER SHALL BE 50KW, 480 VOLT/3PHASE, 4 STEPS OF GONTROL, U.L. LABLED, AIR SAFETY SWITGH AND DOOR DI5GONNEGT. �4 I" DOOR UNDERCUT. C)' �p `-F D Aha a ►l /MANNA MANN ARCHITECTS I NC 3801 5 CAPITAL OF TEXA5 HWY 5U I TE 330 AU5T1 N TX 78'104 TEL: 512.a12.7aa4 FAX: 512.r-i12.7gl5 DON PENN CONSULTING ENGINEER 8060 HIGHWAY M SWE 701 GRAPEVINE, TEXAS 78WM W-47044 FAX 8 4H"-84% 'JUL 12 7004 06.30.04 PERMIT, L.L. REVIEW 4 BID DATE 159JED FOR �7/S ne L:IVWWo{/{/Ul/U��il/i U!!(JIJL�nlhl�ill ull CLAY TERRACE CARMEL, IN 5PAGE #516 H\/AC FLAIL ArNOTE5 M#MA #4084 FINL 5TOR5 #l08 REFER TO PLANS FOF SIZES (TYP BALL VAL1 THERMOME' UNION (TYR DRAIN VAL WITH VAGU BREAKER TO DRAIN CHECK VALVE VAGUUM RELIEF VALVE INLINE EXPANSION TANK TANK SHALL BE STATE MODEL ET -2, 1.% GALLON, MAX. 1.53 AGGEPTANGE VOLUME HOT WATER HEATER TEMPADRE55URE RELIEF VALVE. DISGHARGE TO DRA I N WALL 3" DEEP DRAIN PAN GEILING/STRUGTURE / OF TO I LET ROOM t� F.L.EC7RIC AA7F.R HEATFR F I F I NC -7 5G 1vl'AT 1 C NO SCALE AIR TRANSFER DUCT. REFER TO DRAWING FOR 51 ZE5 1/2" SOUND LINING — GRILLES WITH FIXED LOUVERS (TYP) WALL DUCT STRAP CONNECTED TO STRUCTURE ABOVE (TYP) EXTENSION COLLAR GEILING GRID GEILING A I R TRANSFF.R 17UG7 THRU WALL WIiH CRILLES 17E7AIL NO SCALE NO SCALE 1. FOR ADDITIONAL DETAIL, SPECIFICATIONS AND MALL REQUIREMENTS, REFER TO MALL SHEETS MEP -I, MEP -2 AND MEP -3. /fn\n11= r1 47\-n11r r-, PART PLUMS I Ne PLAN SCALE: 1/4' I' -O" FLOOR q 3 4 ABALL VALVE (TYP.) � EX.3/4" 2 3/4' �� - - - -I� �— - 11 I — - I - r� I I - �i�r 3/ u I I I 1 11 I I I 4 3/4 1/211 3/4 I 3/4 I 1/2" I I II 1( I I I I I E 1 II I I II II W TtP TO I /2'' TO FLOOR 1/2" � 1 /2'4 1 /2'4 1 /2' I 1 /2' I H MOP SINK I DRAIN 1 I I I I PAN DRAIN I I 11 I I II II 8 MOP SINK I I I I I I I I I 4 ANGLE STOP SHUT-OFF VALVE (TYP.) P-2 L' F'_-2 DOMESTIC WATF.R R15ER 171A6RAM NO SCALE O 3 "ySR FLOOR JiL I II— 11 — --- — — ------ ----------------- 211 5 I I I I I I I I I I GEILING I I I I I I I c}— 2" cb— 2" c}-- 2" cis 2" c6-211 ci>- 2" c}— 211 I I I I I I I I I I I I I I I I TO TRAP I I I TO TRAP I I PRIMER PRIMER 12 ti FLOOR P-13" F. D. P-131 P-3 C.O. 311 L311 1_4" L2"1 L3"1_311 L4" I 5AN17AR4%r RIBER :�IACRAY NO SCALE C ENERAL N07EB 1) PROVIDE DIE-ELECTRIG ISOLATORS AT ALL DISSIMILAR METAL CONNECTIONS. 2) PROVIDE STOPS AND AIR GHAMBERS AT ALL FIXTURES. 3) WATERPROOF FLOOR TO A MINIMUM 5" ABOVE FINISH FLOOR. 4) NO PIPING SHALL BE SUSPENDED OR ATTAGHED TO THE ROOF DEGK AND OR FLOOR DEGK. ALL SUGH ITEMS SHALL BE SUSPENDED FROM JOISTS AND/ OR BEAMS. 5) ALL FLOOR PENETRATIONS SUGH AS GLEANOUTS, FLOOR DRAINS, PIPES, ETC., MUST BE FULLY SLEEVED, CAULKED AND FLASHED. 6) NO PLASTIC PIPE SHALL BE APPROVED OR UTILIZED IN THIS PROJEGT. L211 3" RAA I NC NOTE5 ADJUSTABLE TOP SANITARY LINE BELOW SLAB. SLOPE AT A MINIMUM OF 2%. FLOOR DRAIN/ GLEAN EXTEND AND CONNEGT TO EXISTING WATER SERVICE OUT FLUSH WITH TENANT PROVIDED BY THE MALL. VERIFY EXACT LOGATION IN THE PROVIDED FINISH FLOOR FIELD. SURFACE GOLD WATER LINE MOUNTED FROM STRUCTURE ABOVE. SEAL WITH HOT WATER LINE MOUNTED FROM STRUCTURE ABOVE. WATERPROOF SANITARY VENT LINE MOUNTED FROM STRUCTURE ABOVE. GAULKING SANITARY VENT LINE EXTENDED UP THRU ROOF (VTR). WATERPROOF BALL VALVE (TYP). FLASHING 2'-0" STRUGTURE MOUNTED WATER HEATER. HEATER SHALL BE 10 DIA MIN REQUIRED GALLON 2.0 KW STATE MODEL PV-10-IOM5-K, 120V/I (P/60HZ. AROUND OPENING INDEPENDENTLY EXTEND T 4 P AND DRAIN PAN L I NES D I RECTLY ------- OR AS OTHERWISE - 0 -_ B®8008 , REQ. BY LANDLORD EXISTING MALL DOMESTIC WATER PIPING. VERIFY EXACT L � -WATERPROOF MEMBRANE -----___f_J BY TENANT EXTEND SANITARY PIPING TO EXISTING MALL SANITARY PIPING. VERIFY EXACT LOCATION IN FIELD. PATCH FLOOR SLAB d WITH HYDRAULIC FLOOR DRAIN. PROVIDE PPP TRAP PRIMER P-2, GEMENT a FLOOR DRAIN OR 3" FLOOR DRAIN WITH DEEP SEAL TRAP. GLEAN OUT a i EXISTING JOIST/BEAM- CONCRETE SLAB a STRUGTURAL GORE AS REQUIRED FIRE STOPPING NOTE: JO 15T/BEAM 1. TENANT SHALL PROV I DE A WATERPROOF MEMBRANE OVER FLOOR AREA AS REQUIRED BY TENANT CRITERIA (TYP) 2 FI RESTOPPI NG APPLIED PER I NSTRUCTI ONS UNDER MANUFAGTURER'S APPROPRIATE UL TEST NUMBER 7"i F I GAL �=LCCR SRA I N OETA I L NO SCALE 1. FOR ADDITIONAL DETAIL, SPECIFICATIONS AND MALL REQUIREMENTS, REFER TO MALL SHEETS MEP -I, MEP -2 AND MEP -3. /fn\n11= r1 47\-n11r r-, PART PLUMS I Ne PLAN SCALE: 1/4' I' -O" FLOOR q 3 4 ABALL VALVE (TYP.) � EX.3/4" 2 3/4' �� - - - -I� �— - 11 I — - I - r� I I - �i�r 3/ u I I I 1 11 I I I 4 3/4 1/211 3/4 I 3/4 I 1/2" I I II 1( I I I I I E 1 II I I II II W TtP TO I /2'' TO FLOOR 1/2" � 1 /2'4 1 /2'4 1 /2' I 1 /2' I H MOP SINK I DRAIN 1 I I I I PAN DRAIN I I 11 I I II II 8 MOP SINK I I I I I I I I I 4 ANGLE STOP SHUT-OFF VALVE (TYP.) P-2 L' F'_-2 DOMESTIC WATF.R R15ER 171A6RAM NO SCALE O 3 "ySR FLOOR JiL I II— 11 — --- — — ------ ----------------- 211 5 I I I I I I I I I I GEILING I I I I I I I c}— 2" cb— 2" c}-- 2" cis 2" c6-211 ci>- 2" c}— 211 I I I I I I I I I I I I I I I I TO TRAP I I I TO TRAP I I PRIMER PRIMER 12 ti FLOOR P-13" F. D. P-131 P-3 C.O. 311 L311 1_4" L2"1 L3"1_311 L4" I 5AN17AR4%r RIBER :�IACRAY NO SCALE C ENERAL N07EB 1) PROVIDE DIE-ELECTRIG ISOLATORS AT ALL DISSIMILAR METAL CONNECTIONS. 2) PROVIDE STOPS AND AIR GHAMBERS AT ALL FIXTURES. 3) WATERPROOF FLOOR TO A MINIMUM 5" ABOVE FINISH FLOOR. 4) NO PIPING SHALL BE SUSPENDED OR ATTAGHED TO THE ROOF DEGK AND OR FLOOR DEGK. ALL SUGH ITEMS SHALL BE SUSPENDED FROM JOISTS AND/ OR BEAMS. 5) ALL FLOOR PENETRATIONS SUGH AS GLEANOUTS, FLOOR DRAINS, PIPES, ETC., MUST BE FULLY SLEEVED, CAULKED AND FLASHED. 6) NO PLASTIC PIPE SHALL BE APPROVED OR UTILIZED IN THIS PROJEGT. L211 3" RAA I NC NOTE5 lO SANITARY LINE BELOW SLAB. SLOPE AT A MINIMUM OF 2%. O EXTEND AND CONNEGT TO EXISTING WATER SERVICE PROVIDED BY THE MALL. VERIFY EXACT LOGATION IN THE FIELD. O3 GOLD WATER LINE MOUNTED FROM STRUCTURE ABOVE. O4 HOT WATER LINE MOUNTED FROM STRUCTURE ABOVE. O5 SANITARY VENT LINE MOUNTED FROM STRUCTURE ABOVE. �6 SANITARY VENT LINE EXTENDED UP THRU ROOF (VTR). O BALL VALVE (TYP). O STRUGTURE MOUNTED WATER HEATER. HEATER SHALL BE 10 PLW51N6 PLAN/ NOTE5 ANI;) fi�l5�i�5 GALLON 2.0 KW STATE MODEL PV-10-IOM5-K, 120V/I (P/60HZ. INDEPENDENTLY EXTEND T 4 P AND DRAIN PAN L I NES D I RECTLY TO MOP 51NK. PROVIDE UNIT WITH HEAT TRAPS. O EXISTING MALL DOMESTIC WATER PIPING. VERIFY EXACT LOGATION IN THE FIELD. 10 EXTEND SANITARY PIPING TO EXISTING MALL SANITARY PIPING. VERIFY EXACT LOCATION IN FIELD. II GEILING MOUNTED PPI TRAP PRIMER. EXTEND TO EACH FLOOR DRAIN. PROVIDE PPP TRAP PRIMER P-2, PPP TRAP PRIMER AIR GAP, AND DISTRIBUTION UNIT. 12 3" FLOOR DRAIN WITH DEEP SEAL TRAP. CLAMP ROD TO TOP CORD OF JOIST/BEAM- STRUGTURAL JO 15T/BEAM (TYP) ALL THREAD ROD (TYP) - LOGKING NUT (TYP) ■I'�1��1 GLEVIS HANGER SUPPORT ADJUSTMENT (TYP) NUT (TYP) HANGER ROD (TPP) VAPOR BARRIER INI INSULATION BLOCK SUPPORT WHERE REQU I RED TO ELIMINATE INSULATION DAMAGE 16 GA. SHEET METAL SADDLE 12" LONG GLEV 15 HANGER GLEN/15 HANGER NO VAPOR W 1 TH VAPOR BARRIER INSULATION BARRIER INSULATION FIFE SUFf=ORT =�ETAIL NO SCALE NOTE: 1) ALL HANGERS FOR COPPER PIPING SHALL BE COPPER COATED. 1/2" COLD WATER SHUT-OFF VALVE PPP INC. TRAP— PRIMER AIR GAP CEILING 3/5" SOFT COPPER PRIMER LINES FLOOR NEAREST COLD WATER SOURCE PPP MODEL P-2 TRAP PRIMER VALVE DISTRIBUTION UNITS) AS REQUIRED FOR SERVING MULTIPLE TRAPS TO OTHER FLOOR DRAINS IF APPLICABLE PRIMER PIPING IN FURRED OUT WALL. NO PIPING PERMITTED IN LANDLORD'S DEMISING WALLS. FLOOR DRAIN TO LANDLORD'S SPECIFIC CONNECTION. UPPER LEVEL TENANTS TO PROVIDE WATER PROOF MEMBRANE FOR FLOORING. f:% -COQ :BRAIN AN:0 7RAF PRIMER DETAIL NO SCALE r� > A J - - A MM A MAMM A R C H I T E C T S I N C 3801 S GAPITAL OF TEXAS HWY 5U I TE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.9 12.7995 DON PENN CONSULTING ENGINEER 8060 HIGHWAY M SUITE 101 OAAPEVIN� TEXAS 70061 817-410-2866 FAX 81T426WMtl 'JUL 12 2H4 06.30.04 PERMIT, L.L. REVIEW 4 BID DATE 155UED FOR �n�s ne GLAY TERRAGE GARMEL, IN 5PAGE #816 PLW51N6 PLAN/ NOTE5 ANI;) fi�l5�i�5 M$MA #4084 FINL STORE #lob SPLIT SYSTEM AIR HANDLING UNIT SCHEDULE FAN DATA COOL I N& DATA HEATI N& DATA (DUCT HEATER) INDOOR UNIT OUTDOOR UNIT ITEM# AREA SERVED C.P.M. E.S.P. H.P. R.P.M. C•P•M• TYPE TOTAL SENS. EER -TYPE BTU/HR. K.W. STEPS ELECTRICAL MPGR. MODEL NO JNEI6HT ELEG. DATA MPGR. MODEL NO WE16HT ELEC. DATA O.A. BTU/HR BTU/HR DATA AHU-I 5ALE5/5TOCK 5,000 1.00 3.7 850 1,500 DX IgO,000 133,000 10.3 ELECTRIC 170,650 50 4 450/3 CARRIER 40RM014H 700 480/3 CARRIER 38ARD016 150 480/3 NOTES: I) UNIT SHALL BE SUPPLIED WITH HORIZONTAL FAN COIL UNIT, DX COOL I N6 COIL, ELEGTRI G HEAT, FACTORY LINED, OUTSIDE AIR MOTOR OPERATING DAMPER INTERLOCK WITH UNIT AND FULL 51 ZE DRAIN PAN UNDER UNIT. OUTDOOR GONDENS I N6 UNIT SHALL HAVE COMPRESSOR HEATERS, HAIL 6UARD5, LOW AMBIENT CONTROL TO -20"F AND MOUNTED IN PLACE A5 DIRECTED BY LANDLORD. 2) UNIT HA5 BEEN SELECTED ON g5 F. ENT. AIR (GOND). GOI L5 5ELEGTED ON 61.0 ewb 3) ALL INDOOR AND OUTDOOR UNIT5 SHALL BE LABELED WITH TENANTS SPACE NUMBER AND TENANT STORE NAME FL:UMBINe FIXTURE 5CHE1*;)U1F ITEM# DESCRIPTION PIPE SIZES TRAP TYPE E.S.PR.P.M. G.W. H.W. SAN. VENT P -I PgATERGLO5ET 1/2" .315 4" 2" INTEGRAL HANDICAPPED P-2 LAVATORY 1/2" 1/2" 2" 2" "P" HANDICAPPED P-3 5ERVIGE SINK 1/2" 1/2" 3" 2" "P" VIBRATION 150LATION P-4 DRINKING FOUNTAIN 1/2" 5GREH (NP.) 2" 2" "P" HANDICAPPED ROOF IN5ULATION XHAU57 FAN ITEM# AREA SERVED G.P.M. WATTS E.S.PR.P.M. bit CONTROL MANUFACTURE/ MODEL # F -I TOILET ROOM 105 31 W .315 1280 LIGHT 5WITGH BROAN 5L I10 FLUE all II„ 12" 17" 5ET CURB W 1 TH 5EGURE LEG TO CURB ROOFING MATERIAL NOTE: 1) ALL FAN 5HALL BE 120 VOLT/I PHASE 2) FIXTURE5 5HOWN FOR INFORMATION ONLY. EXI5TIN6 FIXTURES TO BE REPLACED IF FOUND TO BE DEFECTIVE. DRAIN PAN EACH D I MEN51 ON 15 EQUAL TO FAN NE6 AT I VE 5TATIG PRE55URE 20 GP METAL GONNE 5TRUG (TYP) 5OPPL DUGT OPPO`. DAMP�,� UNION LOCAL ROOF DRA I N REMOVABLE GAP It ' . SIZE ?RAIN NECTION APPROVED AIR GAP HEIGHT CONDENSATE DRAIN DETAIL Ho scue DOUBLE DEFLECTION SUPPLY AIR RE615TER SHEET METAL COLLAR WITH IN51DE FLANGE AND I" SOUND LINING SUPPLY A I R RF.0 I STAR DET I L NO SCALE I. FOR ADDITIONAL DETAIL, SPECIFICATIONS AND MALL REQUIREMENTS, REFER TO MALL SHEETS MEP -I, MEP -2 AND MEP -3. 20 6AU6E X I" METAL STRAP CONNECTED TO 5TRUGTURE ABOVE (TYPICAL) THRU BOLT-\ IN50LATI O1 ROUND DUC MAX. SAO 1/2" PER FOOT OF SUPPORT 5PAG I N6. FLEX I BLE DUCT RUN- OUT SUFFOR7 DETA I L NO SCALE NOTES: 1) FLEXIBLE DUCT SHOULD EXTEND 5TRAI6HT FOR SEVERAL INCHES FROM REGTAN60LAR MGT CONNECTION BEFORE BENDING. 2) FLEXIBLE DUCT SHOULD NOT EXCEED 5'-0" IN LENGTH. USE R161D ROUND DUCTWORK WHEN RUNOUT5 EXCEED 5'-0". AIR TITS FITTING. PROVIDE 5GREW5 IN EACH PRE-PUNGHED 5GREW HOLES IN CONNECTION RING TO SUPPORT FITTIN LOW PRESSURE �j \ SUPPLY AIRDUGT I 1/8" NEOPRENE 6A5K BALANGIN6 DAMPER FLEXIBLE INSULATED DUGTWORK (MAXIMUM 5'-0 ") FLEXIBLE DUCT CONNECTED TO AIR TITS. CONNECT WITH I" METAL BAND AND PROVIDE MINIMUM 6 5GREW5 (EVERY 600 AIR TITS FITTING DETAIL NO SCALE Alii TITF. SIZE CHART DUGT5IZE CONNECTION RING DUGT51ZE CONNECTION RING 511 bit g:. 12" (o„ rill loll 1311 7" loll 1 1 1$ 15" all II„ 12" 17" 1) HHHERE CONNECTION RING 51ZE 15 LARGER THAN SUPPLY DUCT, THEN GONNEGTION RING 5HALL BE GRIMPED OVER MGT AND CONNECTED, 5GREWED 4 SEALED ON TOP AND BOTTOM OF SUPPLY DUCT. SEQUENCE OP OPERATION SPLIT 5Y5TEM AHU UNIT 1) DURI N6 OCCUPIED PERIOD AS PR06RAMMED ON A550G I ATED AHU THERM05TAT, BLOWER FAN SHALL RUN GONTINUOU5LY AND OUT5IDE AIR DAMPERS AND FAN OPEN TO A MINIMUM. 2) ON A GALL FOR GOOLI N6, THE UNIT MOUNTED GONTROL5 5HALL ENERGIZE UNIT GOMPRE55OR5 (MECHANICAL GOOLINO). THE UNIT GOOLIN6 CYCLE 5HALL RUN UNTIL 5ETPOINT 15 5AT15FIED. 3) ON A GALL FOR HEAT, THE A55OGIATED ELECTRIC HEATING ELEMENT SHALL BE ENERGIZED. 4) DURING NIGHT 5ETBAGK PERIOD AS PROGRAMMED ON A550G I ATED AHU UNIT THERM05TAT, BLOWER FAN 5HALL BE OFF AND OUTSIDE AIR DAMPERS 5HUT. ON A GALL FOR GOOL I N6 OR HEAT I N6, THE OUT51 DE AIR DAMPERS 5HALL REMAIN GL05ED AND THE FAN OR A55OG I ATED HEAT I N6 ELEMENT OR GOMPRE55OR 5HALL CYCLE UNTIL 5PAGE 5ETPOINT5 ARE 5AT15FIED. 5) UNIT 5HALL BE DE -ENERGIZED IF SMOKE DETECTOR 5EN5E5 5MOKE OR ANY 5AFETY/GONTROL EXGEED5 I T5 L I M I T5. EXHAUST FANS I TO I LET ROOM EXHAUST FANS 5HALL BE I NTERLOGKED Hl TH L 16HT 5W I TGH UPON ENER61 Z I N6 Ll G14T5 FAN 5HALL RUN. UPON DE -ENERGIZING LIGHTS FAN 514ALL BE TURNED OFF. REFRIGERANT PIPIN6 AND ELECTRICAL CONDENSING UNIT CONDUIT PER UNIT MANUFACTURERS FANS (TYPE REGOMMENDATI ON5 Avoo VIBRATION PADS (TYP.) 0 5UPPORT CURB • ASSEMBLY FLASHING A55EMBLY, ())77 ROOF (5EE DETAIL) DATE 155UED FOR 5ET CURB W 1 TH 5EGURE LEG TO CURB ROOFING MATERIAL O TO MATCH EXISTING WOOD NAILER ROOF COUNTER THY GURB MODEL FLASHING TEM5-1 (2 REQUIRED) SHELL VIBRATION 150LATION 51 NOLE PLY SHEET METAL ROOFING MATERIAL 5GREH (NP.) STEPPED GANT ROOF I N6 (REFER TO METAL DEGK ARCHITECTURAL DRAW I N65) ROOF IN5ULATION ROOF MOUNTED CONDENSING UNIT DETAIL NO SCALE NOTE: 1) ALL EXTERIOR PIPIN6 IN5ULATED MU5T BE U.V. PROTECTED INSULATION. 2) MOUNT IN PLAGE OF PREY I OU5 UNIT. D I FFU5ER NECK DIAMETER (INCHES 5"-200¢— PROVIDE "-200¢—PROVIDE g0° ELBOW (ADJU5TA5LE) ON TOP OF D I FFU5ER CONNECTION NEGK 5UPPLY AIR DIFFUSER WITH (24"x24" MODULE) UNLESS OTHERW 15E NOTED ON PLANS FLEX I BLE MGT CONNECTED TO ELBOW. CONNECT WITH I" METAL BAND AND PROVIDE MINIMUM 6 5GREW5 (EVERY 600) TOTAL AIR QUANTITY GUBIG FEET PER MINUTE (CFM) FLEXIBLE DUGTWORK (SAME 51 ZE A5 D I FFU5ER NECK SIZE) MAXIMUM 5'-0" AIR PATTERN FLOW. FLOW SHALL BE 4 WAY UNLESS OTHERW 15E I ND I GATED ON PLAN5. SUPPLY A I R D I f22f�USER IG�Y NO SCALE I MI // MANN & AIMM A R C H I T E C T S I N C 5501 5 CAPITAL OF TEXAS HAY SUITE 550 AUSTIN TX 78'704 TEL: 512.912.-79x4 FAX: 512.912.7995 o DON PENN CONSULTING ENGINEER 5060 HIGHWAY SK 8UITE 101 GRAPEVINE, TEXAS 7WM 817-4104M FAX 89-251-"l 'J U- -L 12 2D'D4 FE4�. 'TE CF Avoo 0 I MI // MANN & AIMM A R C H I T E C T S I N C 5501 5 CAPITAL OF TEXAS HAY SUITE 550 AUSTIN TX 78'704 TEL: 512.912.-79x4 FAX: 512.912.7995 o DON PENN CONSULTING ENGINEER 5060 HIGHWAY SK 8UITE 101 GRAPEVINE, TEXAS 7WM 817-4104M FAX 89-251-"l 'J U- -L 12 2D'D4 06.30.04 PERMIT, L.L. REVIEW 4 BID DATE 155UED FOR Fins - ne �l�ollU � �uu GLAY TERRACE GARMEL, IN FACE #816 50HEDULE5 AND BFEC I � I CAT I ON5 MAMA #4084 EINL STORE #lob I. Section 15010 - Basic Mechanical RoQWIromonts A. The work of each of the mechanical sections includes furnishing and Installing the material, equipment, and systems complete as specified and/or Indicated on the drawings. The mechanical Installations, when finished, shall be complete and coordinated, ready for satisfactory service. B. All work under this contract shall be done In strict accordance with all applicable municipal, state, International, County, NFPA, Stateplumbing and energy codes that govern each particular trade. G. The contractor shall make applications and pa all charges for all necessary permits, licenses and Inspections as required under the above codes. Upon completion of the work, the customary certifications of approval shall be furnished. D. No materials or equipment shall be used In the work until approved. Before submission of the shop drawings, and not more than thirty (30) days after award of the contract, the contractor shall submit for approval a complete list of materials and equipment which he Intends To furnish, giving manufacturer and catalog numbers. A complete list of proposed Sub -contractors shall also be submitted. E. The contractor shall examine all drawings and specifications and shall Inspect the existing conditions of the site. Failure to comply with this requirement will not relieve the contractor of responsib111ty for complying with the intent of the contract documents. F. The drawings Indicate the general arrangement of the mechanical installations. Details of proposed departures due to actual field conditions or other causes shall be submitted for approval prior to Reworking eworking of completed Items due to Improper field coordination shall be at the contractor's expense. 6. Provide sufficient access and clearance for all Items of equipment requiring servicing and maintenance, such as valves, dampers, controls, dives, drains, vents, starters, switches, filters, traps, and major Items of equipment. H. The contractor shall perform all necessary cutting and patching as required to complete the Installation of the mechanical work. Patching of walls, floors, callings, roof, etc. Shall match the adjacent surfaces. All roof work Including cutting of the roof membrane shall be performed by the landlords roofing contractor at the mechanical contractors expense. All roofing work Shall be perfomed by the landlords roofing contractor. All floor and wall penetrations shall be water and fire proofed per the landlords criteria. I. The contractor shall prepare three (3) copies of a record and information booklet. The booklet shall be bound in a three-ring loose-leaf binder. Provide the following data In the booklet: 1) Catalog data on each piece of equipment furnished. 2) Approved shop drawings on each piece of equipment furnished. 3) Maintenance, operation and lubrication Instruction on each piece of equipment furnished. 4) Simplified temperature control diagram. 5) Manufacturer's and contractor's guarantees. 6) Air balancing reports. 1) Commissioning reports. 6) Schedule/description of all service work/maintenance Inspections required by paragraphs o, p and q of this section. J. The entire new plumbing system sha I I be tested hydrostatically before Insulation covering Is applied and proved tight under the following gauge pressures: Sanitary piping As specified below Domestic water . .. .........100 prig Refrigeration liquid and suction piping.. 225 pslg/400psig Fire protection ................... Per kFPA K. All waste and vent piping shall be tested by the contractor. The entire new drainage system and venting system shall have all necessary openings plugged and filled with water to the level of ten (10) feet above the main or branch being tested. The system shall hold this water for thirty minutes without showing a drop greater than four (4) Inches. Note: If any code or authority requires testing which Is different than the test listed above, the more stringent test shall be performed. L. Allarts of the heating, ventilating, air conditioning andexhaustsystems shall be adjusted, checked, balanced, and tested by an Independent Certified testing t balancing contractor approved by the owner. The contractor shall put all systems and equipment into full operation, and shall test and balance all devices to within ten (10) percent of copocitles Indicated on the drawings. Submit copies of the balancing reports to the contractor and mall. Permanently mark the position of each balancing damper. M. Upon completion of the mechanical Installations, the contractor shall provide a complete set of prints of the mechanical contract drawings which shall be Iec�Ibly marked in red pencil to show all charges and departures of the Installation as compared with the original design. They shall be suitable for use In preparation of record drawings. N. All piping systems shall be Identified with labels. Materials shall be as manufactured by seton name plate corporation. O. All new mechanical Installations, Including all materials and labor shall be guaranteed for a period of one (1) hr from date of owner acceptance. The above shall not any way void or abrogate equipment manufacturer's guarantee or warranty zertificates of guarantee shall be delivered to the owner. P. Contractor shall also provide one (1)ear free service to keep the equipment In operating condition. This service shall be provided per the following schedule and rendered upon request when notified of any equipment malfunction. Q. In addition to the first year warranty period, the contractor shall provide, at no additional cost to the owner, a minimum of four (4) service calls and maintenance Inspections. A complete outline of the required maintenance and the proposed schedule shall be included in the "record and Information booklet" detailed In sectlon 15010- basic mechanical requirements, paraaggraph I, for review and acceptance by the owner/represenUlve and engineer. The Inspections are to be performed at three M month Intervals for a total of four (4) service calls and Inspections during the first year warranty period (three (3) times during the year plus the orifi nal system start-up commissioning). The service work and Inspections shall Include, but not be limited to the following: - Replace all disposable air filters; - Lubricate all motor and fan bearings as required; - Glean drain pare and drain Imes; - Check and tighten all electrical connections; - Inspect all belts for adjustment and condition and replace as required; - Check operating pressures and refrigerant charge; - Inspect all controls for correct operation and calibrate as required; - Perform all maintenance as outlined In the equipment manufacturers operation and maintenance manuals. YECH,A%N I CAL. SPEUFIGATIONS Upon completion of each scheduled Inspection, the contractor shall deliver to the bulldlnc� owner/owner's representative within forty-eight (46) hours of completion, two (2) copies of the completed Inspection report for record purposes. R. The mechanical or service contractor shall, at the ninth month, advise the owner of the termination date of the above service. This contractor shall also provide the owner with a detailed proposal, reflecting annual escalation, for the continuation of the service and Inspections described above. 5. All roof mounted equipment shall be identified with tenants name, space number and equipment Identification on phenolic labels corresponding with drawings. 2. Section 15050 - Basic Mechanical Plnina Material d Methods A. Provide all labor and materials necessary to furnish and Install all piping systems on this project, Including , vent, domestic water, condensate drainage, refrigerant piping systems. B. Piping and valves shall be as follows: 1) Sanity wastes and vents below floor Irelde building.. Pipe Gast Iron uncoated bell 4 spigqot soil pipe Piping shall be standard welg-ht cast Iron. Fittings Standard weight cast Iron bell 6 spigot uncoated loll pipe fittings Joints Neoprene push lock fittings 2) Swlt= wastes and vents above floor Inslde bulldinQ Pipe Gast Iron no -hub soil pipe Fittings Cast Iron no -hub soil pipe fittings Joints No --hub stainless steel gasketed fittings 3) Domestic hot and cold water 1211,1= Pipe All water lines - hard copper type L above grade and type K below grade Fittings Solder type wrought copper - lead free solder. cB/5 with L. Silver solder with K. Ball valves two place body, 150 Ib. chrome plated full port bronze body and stem, reinforced tfe seat rings, Nibco 5-565-70. Unions 125 Ib. Wrought copper, ground joint solder ends. 4) Atmosvheric condensate drains: Pipe Type dwv seamless copper tubing. Fittings Wrought copper solder drainage fittings 5) Refrigerant ^ming_ Pipe Type L hard copper refrigerant tube, dehydrated and sealed. Fittings Wrought copper solder type with silfos. 6) Fire vroom taction: Piping and fittinnggs5 as r wired by NFPA regulafions and s hereinafter specified. G. Copper pipe shall be revere, anaconda, or chase types "L" hard dawn, with approved solder fltt". D. Gast Iron piping shall be service weight drainage piping and shall conform to the requirements of the G.1.5.P.1. Each length of pi and each fitting shall be clearly mar with the manufacturer's Initials and pipe closslflcatlons. E. All hangers for copper piping shall be copper clad, split ring swivel type, having rods with machlne reads and threaded copper clad celllng flange. Gast Iron and steel piping supports shall be- similar without copper clad and prime paint finish. F. Provide dielectric couplings where non-ferrous metal piping is joined to ferrous metal piping. The gasket material shall be capable of withstand) the tempreatures and pressures within the plping system In which Installed. Submit dielectric coupling and gasket material for approval. 3. Section 15250 - Mechanical Insulation A. All supply, return and outside air ductwork, domestic water and condensate piping systems shall be Insulated with fiberglass Insulation. B. Outside ductwork shall be insulated with 1-1/2" flexible duct wrap, owens corning fiberglass type 75 with foil faced vapor barrier. Insulation shall be neatly Installed. C. Pipe Insulation shall be I' premolded fiberglass Insulatlon with an all servlce Jcwket, owens corning fiberglass 551 -II. Fittings shall be Insulated and covered with pvc covers. D. Interior duct Ilning shall be as specified under section 15680. ►3 A. All work, materials, equipment, and accessories shall comply with the standards of the national fire protection association and all state and local regulations. B. Extend the existing wet pipe sprinkler system/stub to properly cover/protect the tenant space. System shall generally be Ordkiary Hazard II.Maxlmum 130 square feet per head and .17 gpm o 3000 square foot. G. The modifications shall include, but are not limited to valves, flow switches, sprinkler heads and escutcheons, piping, fittings, hangers and signs and other 1dent1flcation mark", as required. D. The sprinkler contractor shall carefully examine all documents during the bidding period. His shall famlllarize himself with project conditions such as bulidl construction d pipe and ductwork locations and a 6e g1". an E. Sprinkler heads shall be Installed to meet the new layout. SprWer heads shall be quick response type. Sprinkler heads in finished drywall cell" shall be brushed chrome fully concealed/recessed type. All heads In open bay areas with no cellkng shall be bronze upright type. Shall comply with landlords crlterla and approved by landlords on site reprsenat" and local code cLd ority. F. The contractor shall arrange for approval of the sprhkier systems, and conduct tests in accordance with NFPA M. 6. The sprinkler contractor shall provide a detailed shop dawkng showing pip lncl layout, head locations, elevations and coon not on with all mechankal, electrical and pItrades. The contractor Shall submit detailed sprt�k or shop drawings with actual heads for architect approval prior to any fabrication. H. The sprinkler contractor must submit one sepla of sprinkler shop drawings and hydraulic calculations to tenant coordinator, county fire depar'trnent and landlords Insurance underwriter prior to any faabbrriceMon or construction. 5. Section 15400 - Plumbing A. The work covered by this section of the specifications consists of furnishingall labor, equipment and materials in connecon with the rough -In, final setting and connections to all plumbing fixtures. The contractor shall carefully review the conditions at the site and all of the contract drawings to determine the extent of the new plumbing work required. B. All plumbing fixtures shall be complete In every detail with all trimmings and connections. All fixtures shall be designed to prevent the backflow of polluted water or waste Into the water supply system. Fixtures shall be American Standard or approved equal as follows: All fixtures shall comply with ADA and water conservation act. L-1 Water Closet (handicapped): #2166.100 elongated 17" high, water saver cadet Ib gallon flush with vitreous china construction, siphon jet action bowl, close -coupled tank, water saver trim, bolt caps, closet flange, church -open front seat with cover, rigid supply with angle stop valve. Toilet and seat shall be white. Wa I I hung #0355.012 lucerne with vitreous c.'hlna construction, front overflow, faucet ledge. Lavatory to be fitted with Moen #6666 metering self close faucet and be complete with grid drain, tailpiece, cast brass "p" trap, tubing to wall escutcheon, key operated supply valves with rigid supplies and chair carrier. All exposed waste piping and hot and cold water piping shall be Insulated with truebro handl lav -guard model 102 Insulation kit with white finish. Fixture shall be white. P-3 Service Sink: Fiat model M552424, 24"x24"x10" deep molded stone with stainless steel caps 3" outlet, model 630 -aa service faucet, model 632-oa hose and hose bracket, model 66g -cc mop hanger, model E -TI -AA bumper guard, model 1453 bb alternate strainer and model 533 -aa silicone sealant. Caulk all sides at wall and floor lines. P n : Oasis model M55LPM wall -hung, barrier -free wheelchair level. Unit shall be constructed of heavy gauge 5tainle55 steel, with chrome plated push bar, one-piece bubbler. G. The water heater shall be State, or an approved equal. Heater shall be rated at volts and phase as Indicated on drawings and be listed by underwriters' laboratories. Tank shall be factory fired Wlth glass Ilning with 150 psi working pressure and equlppad with extruded high density magnesium anode at t # p relief valve. Electric heating element shall be series one medium watt density with zinc plated copper sheath. The controls shall Include a thermostat with each element and a high temperature cutoff. The jacket shall provide full size control compartments for performance of service and maintenance thru front panel openings and enclose the tank with Insulation. The drain valve shall be located 1n the front for ease of servicing. Outer jacket shall be baked enamel finish. Heater shall have a three (3) year limited warranty for commercial Installation, as outlined In the written warranty. Fully Illustrated Instruction manual shall be Included. Insulation must meet Ashroe standard clOa-1460 for energy efficiencies. Refer to drawings for size, capacity and voltage. D. Potable water systems shall be disinfected prior to use. The method to be followed shall be that prescribed by the health authority and code requirements and LL.5 criteria.. 6. 5ectlon 15500 - Heating, Ventilating 4 Air Conditioning (HVAC) A. The work to be performed shall include all labor, materials and equipment necessary to furnish and Install complete, all hvac mechanical equipment as shown on drawings and/or hereinafter specified. It Is the intent that the Systems be Installed complete with all Items necessary to provide satisfactory service. B. All heating, ventilating and air conditioning equipment which contains compressors shall be provided with extended warranties (minimum four (4) years) for the compressors. G. Split System Air Handling Unit shall be Indoor mounted, direct expansion, packaged fan toll unit capable of horizontal or vertical floor Installation. Unit shall be suitable for ducted systems and shall consist of a fan, evaporator toll, and filter. Unit shall be matched with a factory approved condensing unit. Unit shall be rated in accordance with ARI standard 2107240-64, comply with AN5I/A5HRAE 15 safety code and carry the UL label. Unit shall operate on a nominal 460 volt, three phase, 60 cycle distribution system. Unit cabinet shall be constructed of prepainted galvanized steel, Internally lined with 1/2" fire retardant Insulation. Indoor air fan shall be of the forward curved type, statically and dynamically balanced at the factory. fan motor shall be a be -It drive and of the size and electrical characteristics specified on the equipment schedule. Evaporator toll shall have 3 rows of copper tubes, mechanically bonded to plate the aluminum fins. Tubes shall be grooved Internally and fins shall be o the lanced sine -wave, type for enhanced heat transfer. Condensate drain pan shall be constructed of high Impact PVG to preclude sweatInci, and shall have left and richt side drain connections. Droln pans shall Have the obilitq to be sloped toward the right or left to prevent standing water from accumulating In the pan. Refrigerant metering device shall be a factory installed thermostatic expansion valve. the TXV's shall be capable of external adjustment. Filters shall be factory supplied 2" throw away type. Filter access shall be from the left or right side of the unit. The following accessories for field Installation shall be provided: I. Electronic 7 -day programmable space thermostat with digital time and temperature display. Thermostat shall be 24 hour/7 day programmable thermostat. Tfiermostat shall be Honeywell Model T-7300 or approved equal. 2. Heater for nominal 480v/3ph/60hz power supply shall be ETL approved and shall have single point power wiring. Heater assembly shall Include contactors with 24v coifs, power wiring, 24v control wiring terminal blocks, and a hinged access ponel. Unit shall be Garner, York or Trane. D. Air Cooled Condensing Unit shall be outdoor mounted, air cooled, split system air conditioner unit suitable for roof or grade installation. Unit shall consist of a hermetic compressors, an air cooled toll, propeller -type condenser fan, and a control box and shall discharge supply air upward as shown on contract drawings. Unit shall be used In a refrigeration clrcult to match up to a packaged air handling unit. Unit shall be rated In accordance with the latest edition of ARI standard 210 and 210 and shall be certified for capacity, efficiency, and sound and listed In the latest ARI directory. Unit construction shall complyy with latest edition of ANSI/A5HRAE and with NEG. The Unit shall 6e constructed In accordance with UL standards and will carry the UL label of approval. Unit cabinet shall be capable of withstanding Federal Test Method Standard No. 141 (method 6061) 500 -hour salt spray test. Air cooled condenser tolls will be leak tested at 150 psig and pressure tested at 300 psig. Unit shall be factory assembled, single piece, air cooled air conditioner unit, contained within the unit enclosure Is all factory wiring, AlpIng, contr( I compressor, refrigerant charge (r-22), and specTai features required prior to fleld start-up. Unit cabinet will be constructed of galvanized steel, bonderized and coated with a powder coat paint. condenser fan will be direct drive propeller type, clischorgina air upward. Condenser fan motors will be totally end7osed. I -phase v4pe with class b Insulation and permanently Tubricated bearings. fliafts will be corrosion resistant. Fan blades shall be statically and dynamically balanced. Gondensor fanopenings shall be equipped with pvc coated steel wire safety guards. Unit compressor shall be hermetically sealed and mounted on rubber vibration Isolators. compressors shall Include overload protection. The condenser coil shall be air cooled and circuited for integral sub -cooler. Goll shall be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration circuit components shall Include liquid line service valve suction line service valves, liquid filter dryer, system charge of refrigerant R-22, and compressor oil. Electrical characterlstics shall be 480v, 3 phase, 60 hertz. Unit electrical power shall be single point connection. Unit control circuit shall contain a 24v transformer for unit control Minimum control functions shall Include control wire terminal blocks and compressor lockout on auto -reset safety until reset from thermostat. Minimum safety devices shall Include high discharge pressure cutout and loss -of- age cutout. Unit shall be Carrier, York or Trane. 7. Section 15660 - Air Distribution A. Furnish all labor and materials necessary to complete the sheet metal work associated with the heating, ventilating, air conditioning and exhaust systems, and other ml5celTaneou5 Items shown and required. B. All ductwork shall be constructed and Installed In accordance with the sheet metal and air conditioning contractors national association (smacna) standards, ashroe standards and bora standards. G. Flexible ductwork shall be hart 4 cooleyttype f214 or approved equal. Flexible duct shall comply with nfpo bulletin clOo and shall be U.L. listed as class I air duct and connector, standard 161. D. Support horizontal ducts with hangers spaced not more than six (6) feet apart. Use straphangers for ducts up to thirty (30) Inches wide, angle hangers or rods for ducts over thirty (30) inches wide. Straphangers to be one (1) Inch wide, 20 gauge minimum; fasten to sides and bottom of duct with sheet metal screws. E. Ducts shall be straight and smooth on the inside, with Joints neatly finished. Ducts shall be suspended from the construction and shall be free from vibration. Curved elbows shall have a center radius equal to one and one-half (1-1/2) times the width of the duct. All square turns shall be vaned. Vanes consisting of curved metal blades shall permit the air to make abrupt turns without turbulence. F. All Joints In the heating, ventilating, air conditioning and exhaust system ductwork shall be seared. Sealant shall be a5 manufactured by Hardcast Inc. model vg -105. Sealant shall be smocna and UL approved, with a flame spread of S and a smoke developed of 0, non-toxic and non-flammable. Sealant shall be approved for operating temperatures from 0 degrees f. to 200 degrees f. Sealant system shall be Installed In strict accordance with the manufacturer's recommendations and when applied shall provide a permanent seal without any deterioration. 5. All supply and return air ductwork within twenty (20) feet of each air handling unit or visible In open sales area shofl be lined on the Interior for sound attenuation. Lining shall have a one (1) Inch thickness and shall be glued with one hundred (100) percent coverage and additionally secured with pins. Increase duct sizes Indicated two (2) Inches direction to accommodate the Interior lining. H. Supply air diffusers shall have all steel construction, Titus model TMS with vaned face and finished with #26 off-white enamel. Diffusers in sales areas shall have 24'x24" module. Diffusers in office, break areas, etc., shall have 12"xl2" module. all diffusers shall have plaster frame for access to above Callings. I. Return air grille shall have all steel constuctlon, Titus model 25R with louvered face and finished with #26 off-white enamel. J. Supply air registers shall be double deflection type with opposed blade dampers with all steel construction. Registers shall be Thus model 30ORS with #26 off-white enamel finish. 6. 5ortlon 15850 - Controls A. The contractor under this hoodIng shall furnish and install all wiring necessary for a complete electric system of automatic temperature control. The system shall Include all necessary thermostats, relays, switches, etc. Required for successful operation. Electrical work In connection with the temperature control system shall be performed by the control contractor. B. Each air handling unit shall be controlled by a wall mounted honeywell model T-7300 heatingTcooling thermostat with a seven (7) day twenty-four (24) hour program clock. Thermostat assembly shall be compatible with the condensing units and accessory heater package. Coordinate control requirements with proposed equipment. G The automatic temperature control contractor shall be responsible for the commissioning of the project to assure a fully functional, fine-tuned hvac system upon occupancy. The commissioning of the project shall be performed In accordance with americon society of heating, refrigerating and air conditioning engineers, inc. (Ashroe) pamphlet I-Ig6g guideline for commissioning of hvoc systems. commissioning Is defined as verification of the proper operation of all equipment, alarms, safeties and control and energy management systems serving mechanical systems installed or modified on this project as deflned within the specifications and Indicated on the contract drawings. Proper operation Is defined as the activation of all controls, field or factory Installed, to assure the correct sequencing of equipment and systems, Including activation of all operating and safety controls, as hereinbefore described. The automatic temperature control contractor shall report all system deficiencies to the mechanical contractor. The mechanical contractor shall instruct the proper trade to correct any deficiencies reported by the automatic temperature control contractor so that the project commissioning can be completed. Prior to the commencement of any commissioning work, the automatic temperature control contractor shall provide the engineer with a commissioning report format for review and approval. The Report format shall be delivered to the engineer not more than thirty (30) days after award of the atc contract or not less than sixty (60) days prior to start of ata work, whichever Is earlier. commissioning report format shall Include a list of all Items to be verified, with the Initials of the mechanic who verified the particular Item/control and the date on which each Item/control operation was verified. Three 0) commissioning reports are required. The first report shall be completed during the Initial commissioning of the project prior to occupancy. The second and third reports shall be completed no more than two (2) months (I report/month) after occupancy of the building. All controls/safeties shall be verified In the presence of the owner/owner's representative. The final report shall also contain the signature of the owner or owner's representative for each Item verif led. NOTE I. FOR ADDITIONAL DETAIL, SPECIFICATIONS AND MALL REQUIREMENTS, REFER TO MALL SHEETS MEP -1, MEP -2 AND MEP -3. = O ,-A':. ST - - /NANN & /MANN ARCHITECTS I NC 5501 5 CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 18'104 TEL: 512.eI12.7aa4 FAX: 5I2.a 12.7aa5 DON PENN CONSULTING ENGINEER 3860 HIGHWAY 8606 8lJITE 101 ORAPEVINE, TEXAS 76061 W-410-2868 FAX W4101 -84M JUL 12 2004 06.30.04 PERMIT, L.L. REVIEW 4 BID DA7E 155UED FOR Fines ne uafr�w�aCc�o�v CLAY TERRACE CARMEL, IN 5PAGE #Bib MECHANICAL SFEG I � I GAT 10N MAMA #4084 Y4 FINL STORE #108 MECHANICAL CRITERIA GENERAL ® Tenant's drawings are to clearly show ALL modifications to existing installation that are required to accommodate Tenant improvements. ® Tenant improvement HVAC documents shall be prepared and stamped by a Registered Professional Engineer. ® This document is to be used as a checklist to verify compliance with Mall Design Criteria. ® Unless already existing and in compliance with Landlord's requirements. Tenant is required to install, upgrade and/or furnish any and all equipment, ductwork, etc. for Tenant's HVAC service installation. ® The design, materials and installation shall conform to the best current practice in the respective trades and shall be consistent with good engineering practice, manufacturer's recommendations, industry technical references and standards. ® Any modification or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawing submission. Upgrades shall be subject to availability. ® Modifications to existing systems that are required to accommodate Tenant improvements shall be clearly defined in both in the written request for deviation and on the contract documents. ® Any unused hvac equipment, ductwork, piping, wiring, etc within or serving the demised premises must be removed. STRUCTURE ® Locate RTU where designated by Landlord or provide written documentation by a registered structural engineer where alternate location is proposed or a location is unavailable. ® When required, Tenant shall provide supplemental structural support framing designed by a licensed structural engineer employed by Tenant to adequately support the Tenant's equipment. The Landlord may require that engineering analysis, review or design be performed by Landlord's engineer at Tenant's expense. ® No alterations, additions, reinforcements or modifications to Landlord's structure to accommodate Tenant's work shall be performed without obtaining Landlord's prior written approval. The Landlord may require that approved structural modifications be performed by the Landlord's contractor under contract to Tenant at Tenant's expense. ® Tenant shall not drill, screw, weld or shoot into Landlord's structure or structural members. All attachments shall be with beam clamps, clips or bolts with washers. Do not attach any construction directly to Landlord's roof deck. Joists, beams, trusses and girders may be used for lateral bracing and spanning support. Do not support any construction from Landlord's crossbracing or bridging. SPLIT SYSTEM UNIT ® Tenant must incorporate HVAC load calculations into their submission to the Landlord. A form has been provided on this sheet for tenants who prefer not to perform more detailed calculations. All calculations shall be performed per ASHRAE. ® Unit must be sized appropriately to maintain space comfort. As a guideline, the unit shall be sized for 90% to 110% of the calculated load. ® Tenant shall provide a new hvac unit(s) with the following exceptions: ® Unit is less than 10 years old or ® Landlord has approved of the reuse of existing hvac unit(s) in writing before construction begins. ® Landlord will not consider permitting the reuse of existing hvac unit(s) until the following has been submitted by Tenant in writing: ® A report on the capacity and condition of the existing equipment by a company employing full time certified refrigeration specialists. This report shall include test data used in confirming the equipment's capabilities and shall be signed by the Tenant's Mechanical Engineer, indicating they have reviewed the information and find it accurate and the equipment suitable for reuse. ® Contract documents shall describe the minimum performance parameters, refurbishing specifications and establish a verification procedure, including a report to be submitted to the Landlord after work has been completed. ® Cabinet shall be constructed with galvanized double wall panels, with the inner solid metal liner encapsulating a minimum of 1", 1 1/2 Ib. density fiberglass insulation. No insulation may be exposed to the airstream. Access panels and doors shall be gasketed. ® Condensate drain pan shall be stainless steel, with a mastic coating on the reverse side to prevent sweating. ® Motors 1/2 HP and larger shall be three phase. Motors shall be mounted inside the unit casing. All drives to be variable pitch, with adjustable motor base. ® Fan shafts to be solid, not hollow tubing. Bearings shall be 200,000 hour pillow blocks. Inaccessible bearings shall have extended lubrication lines. ® Heat shall be supplied by an electric heat coil in the air handler or duct system, (if required). Provide with an independent disconnect switch. ® Provide a computer print-out of split system performance for Landlord review. ® Indicate column line designations on HVAC plan. ® Specify hail guard on condensing coil. ® Tenant's HVAC contractor must label all of the Tenant's rooftop equipment to ensure proper identification. ® Tenant's equipment shall not transmit vibration to the building. Provide vibration isolators for all split system components. Condensing unit shall be attached to roof structure with manufactured equipment support rails. All roof work shall be done by the Landlord's roofing contractor at Tenant's expense. NOTE: THE MAXIMUM ALLOWABLE TONNAGE FOR CONDENSER UNITS SHALL BE 10 TONS DUE TO WEIGHT LIMIT AND SITE RESTRICTIONS. ALL UNITS BEYOND THIS CAPACITY WILL NOT BE APPROVED WITHOUT LANDLORD'S WRITTEN CONSENT. AIR DISTRIBUTION ® All ductwork shall be galvanized sheet -metal, designed, shop fabricated and installed to SMACNA standards. Ductboard is not permitted. ® All supply air ductwork externally shall be insulated with 1-1/2" thick foil face insulation. ® Internally lined ductwork may be used for acoustic purposes only, NOT as a substitute for external insulation. ® Externally insulated flexible duct, not to exceed 5'-0" in length, may only be used for connection to supply diffusers. Flex duct shall be fastened to metal duct and diffuser with mechanically tightened draw bands. ® Install volume/control dampers on each duct to a diffuser. ® The heat gain from enclosed display windows must be ventilated. RETURN AIR ® An open ceiling plenum return air system shall be used. Ducted return system is not permitted except at food tenants and other odor producing tenants or as determined by the Landlord. ® Provide return / relief grilles. Size at one square foot of grille for 300 square feet of gross leasable area. TOILET EXHAUST ® Tenant shall provide a ceiling exhaust fan, with a backdraft damper sized to overcome the resistance of Tenant installed components and all ductwork. Minimum duct size shall be 6" diameter. ® The toilet room light switch (with delay timer if included) shall control the fan to provide intermittent operation. ® Tenant shall use central toilet exhaust duct where one exists. Exhaust systems requiring continuous operation or exhaust requirements in excess of 150 CFM must be provided entirely by the Tenant and routed independently to the building exterior. ® Where the Landlord central toilet exhaust duct does not exist tenant shall discharge directly to roof. Locate roof penetration a minimum of 10' from any existing outdoor air intakes or designated equipment locations. Gooseneck type exhaust discharge is prohibited. All roof work associated with exhaust system, shall be performed by Landlord's designated roofer at Tenant's expense. AIR BALANCE ® Incorporate a outdoor / exhaust air balance summary onto design drawings. ® Tenant must employ an air balancing firm designated by the Landlord. Provide a certified air balance report to the Landlord when construction has been completed. INDEX 02/13/04 MEP -1 MECHANICAL CRITERIA DOCUMENT CHECKLISTS SIMON AND DETAILS. PROPERTY GROUP MEP -2 ELECTRICAL AND PLUMBING CRITERIA DOCUMENT CHECKLISTS AND DETAILS. NATIONAL CITY CENTER P.O. BOX 7033 MEP -3 SPECIALTY TENAT CRITERIA DOCUMENT CHECKLISTS AND DETAILS. (ONLY WHEN INDIANAPOLIS, IN 46207 REQUIRED) (317) 636-1600 CARMEL - rNDIANA REVISED ON: 6/10/04 4 REFRIGERANT PIPING ® Refrigerant piping shall be ACR copper tubing, cleaned by manufacturer, ends capped. "Line sets" are not permitted. ® Pipe hanger design shall prevent vibration from being transmitted to the building structure. ® Roof -mounted piping shall be installed on free floating, prefabricated supports similar to Miro model 24-R on walkway tread pads. Remove ballast (stones) from beneath any roof support. The use of wood for supports is prohibited. ® All roof pipe penetrations shall be made through a pre -molded flashing, specifically manufactured for the mall's roofing system, with a UV -stable neoprene or EPDM boot that conforms to the size of the pipe. Flexible piping or conduit shall not pass thru roof penetrations or flashings. ® Insulate refrigerant piping with plenum rated closed cell insulation. CONDENSATE DRAINAGE ® Condensate Drain and trap shall be copper. Condensate trap should be at a depth sufficient to overcome positive/ negative static pressure of fan (3" minimum). ® Route rooftop unit condensate drain into the building through a waterproof penetration in the side of the tenant's rooftop unit curb, down into the tenant's lease space and discharge into tenant provided floor drain or a where applicable into a condensate main provided by the Landlord. ® Condensate drain piping shall be insulated and pipe installation shall also include a cleanout at each change in direction. ODOR PRODUCING TENANTS ® Tenants with internally generated odors or other contaminates such as ALL FOOD PREPARATION areas, Nail Salons, Hair Salons, Pet Shops, Photo Processors, and others at the sole discretion of the Landlord, shall maintain an exhaust air system sized for 50 cfm per square foot of storefront opening. Also at the sole discretion of the Landlord, the exhaust air system may be reduced to 25 cfm/square foot of storefront opening when a "buffer" of at least 10 feet has been provided between any odor producing element within the tenant space and the storefront opening. This buffer may be retail displays, reception counters or other similar permanent elements. ® Replacement (make-up) air shall be draw from mall Common Area for exhaust systems up to 2500 SCFM and from dedicated makeup air units for larger exhaust capacities. Total replacement air through makeup air units and outside air through the air conditioning unit shall be a minimum of 10% less than the exhaust air quantity. ® Exhaust Calculation for Odor Producing Tenants: Storefront opngr--Jft2 (xf-­ICFM / ft2== CFM ® Tenant shall install an indicator pilot lamp 12" above thermostat for the purpose of verifying exhaust fan operation. ® Odor exhaust and makeup air fans' operation shall be continuous during occupied hours. MECHANICAL CRITERIA Split System - Standard Checklist HVAC CONTROLS ® Control system shall employ a seven day timeclock or programmable thermostat to automate equipment operation. Supply fan operation shall be continuous during occupied hours. ® Controls shall provide for closure of outside air dampers when fans are off to prevent uncontrolled infiltration of air. The outside air damper shall be opened during occupied operation. CONTACT INFO MARK AHU-1 MANUFACTURER, E.E.R. RATING CARRIER 10.3 SPLIT SYSTEM SPECIFICATIONS SATURATED SUCTION TEMP. 45 REFRIGERANT R-22 SATURATED COND. TEMP. 95 AIR ENTERING CONDENSER 95OF db CONDENSING UNIT AIR HANDLING UNIT H.V.A.C. CALCULATION FORM SUMMER SPACE 75°F @ 50% R.H. OUTSIDE ASHRAE 1% DATA/ HEATING SPACE 70°F OUTSIDE ASHRAE 99.6% DATA MODEL NO. 38ARD016 HEAT LOSS SPACE SENSIBLE PLENUM SENSIBLE LATENT WEIGHT 700 LBS. HEAT GAIN HEAT GAIN HEAT GAIN ITEM QUANTITY FACTOR BTUH FACTOR BTUH FACTOR BTUH FACTOR BTUH 1. ROOF AREA TOTAL COOLING 190,000 BTUH FAN DATA: 850 RPM 3.7 133,000HP BTUH PRESSURE DROP "WC W/ CEILING 0 SQ. FT. (3.51) ♦♦ 0 (4.17) ♦♦ 0 (6.86) ♦♦ 0 2. ROOF AREA W/O CEILING 5001 SQ. FT. (3.5 1) ♦♦ 17554 (6.43) ♦♦ 32157 SPACE SQ. FT. 0 0 3. CORRIDOR (3.44) ♦♦ (3.44)♦♦ WALL: PLENUM SQ. FT. 0 0 (3.44) ♦ ♦ (2.64) ♦ ♦ SPACE 2000 SQ. FT. (7.56) ♦♦ 15120 12840 4. OUTSIDE (642) ♦♦ WALL: PLENUM 0 SQ. FT. 0 W///(5.86) 0 (7.56) ♦ ♦ ♦ ♦ 5. RECESSED ♦ LIGHTS 0 KW 2048 1365 6. SURFACE ♦ 11.175 KW 3413 38128 LIGHTS 7. PEOPLE (GLA/100)= 50 250 12500 200 1000 8. APPLIANCES '5W VJ I 8535 (SEE APPL. CALC. FORM) 9. FAN MOTORS 5 HP 2545 12725 10. OUTSIDE * (GLA) (0.2 CFM / SQ. FT).= AIR 1000 CFM -- (89.6) �k 89600 (19.4) 19400 23500 (23.5) �k 11. HEAT LOSS AND GAIN TOTALS: 122274 123560 12725 33500 12. TOTAL SENSIBLE HEAT GAIN: SPACE SENSIBLE + PLENUM SENSIBLE _ 136,285 BTUH 13. TOTAL LATENT HEAT GAIN: = 33,500 BTUH 14. TOTAL HEAT GAIN: TOTAL SENSIBLE + TOTAL LATENT = 169,785 BTUH 15. AIR QUANITY: SPACE SENSIBLE _ 136,285 BTUH (1.08) (75° - LAT-) (1.08) (75° - 55') 6,309 CFM 16. HEATING MIN. REQ'D.: RECIRCULATION CFM x 1.08 x 20,&T ( ) x 1.08 x 20,&T _ 36 KW 3413 BTU/KW 3413 BTU/KW LOAD CALCULATION KEYS: �k VARIES BASED ON SPECIFIC OCCUPANCY AND ♦ DATA FROM ♦♦ ROOF AND WALL FACTORS ARE U x OT's USE. REFER TO BUILDING CODES. DEFAULT ELECTRIC (CLTD's/CLF's) FROM ASHRAE. DEFAULT DATA, WHERE TENANT CHOOSES TO NOT SUMMARY DATA, WHERE TENANT CHOOSES TO NOT PROVIDE MORE ACCURATE CALCULATIONS ARE PROVIDE MORE ACCURATE CALCULATIONS IS SHOWN IN PARENTHESES. ARE IS SHOWN IN PARENTHESES. GLA = GROSS LEASE AREA LAT= LEAVING AIR TEMPERATURE (°F) MARK AHU-1 MANUFACTURER, E.E.R. RATING CARRIER 10.3 SPLIT SYSTEM SPECIFICATIONS SATURATED SUCTION TEMP. 45 REFRIGERANT R-22 SATURATED COND. TEMP. 95 AIR ENTERING CONDENSER 95OF db CONDENSING UNIT AIR HANDLING UNIT EVAPORATOR COIL_ MODEL NO. 38ARD016 MODEL NO. 40RM014H MODEL NO. WEIGHT 750 LBS. WEIGHT 700 LBS. AIR ENT. COIL 77.1 Fdb 64.7 Fwb VOLTS/PHASE/HERTZ 480W30/60HZ VOLTS/PHASE/HERTZ 480V/30/60HZ AIR LVG. COIL 56.5 Fdb 55.4 Fwb E.E.R. RATING 10.3 TOTAL AIRFLOW 5000 CFM ROWS 4 CIRC FINS COMP. PWR INPUT K.W. TOTAL STATIC PRESSURE 1.0 W.C. TOTAL COOLING 190,000 BTUH TOTAL COOLING 190,000 BTUH FAN DATA: 850 RPM 3.7 133,000HP BTUH PRESSURE DROP "WC ACCESSORIES: COIL FACE AREA SQ.FT. FACE VELOCITY FPM W LOW LEAKAGE SEALS ON O.A. DAMPERS LOW VELOCITY FILTERS ECONOMIZER O (YES) a(NO) OR LOW AMBIENT CONTROL TO 0°F ®(YES) O(NO) REMARKS: REFER TO SHEET M-3 FOR SCHEDULE For questions regarding site access, storefront & architectural criteria, engineering design, delivery dates, construction rules & regulations, the scope of Landlord's and Tenant's work and store opening requirements, please contact your Tenant Coordinator or call 317-636-1600 for assistance. • � - �--._ _- et A t1 A RE; ; `i01`_ J OF X� . CLAY TE L 14311 Clay Terrace Boulevard Carmel, Indiana 46032 MEP -1 ELECTRICAL NOTES GENERAL ® Tenant's drawings are to clearly show ALL modifications to existing installation that are required to accommodate Tenant improvements. ® Tenant improvement electrical documents shall be prepared and stamped by a Registered Professional Engineer. ® This document is to be used as a checklist to verify compliance with Mall Design Criteria. ® Unless already existing and in compliance with Landlord's requirements, Tenant is required to install, upgrade and/or furnish any and all equipment, wiring, conduit etc. for Tenant's electrical and telephone service installation. ® The design, materials and installation shall conform to the best current practice in the respective trades and shall be consistent with good engineering practice, manufacturer's recommendations, industry technical references and standards. ® Any modification or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawing submission. Upgrades shall be subject to availability and based upon a justified need. ® Modifications to existing systems that are required to accommodate Tenant improvements shall be clearly defined in both in the written request for deviation and on the contract documents. ® Modifications and final connections to existing Landlord systems shall be performed by a contractor designated by the Landlord at Tenant's expense. ® Tenant may or may not be a customer of the Utility Company, however the design should be executed as if Tenant was aquiring power directly from the Utility Company. ® Temporary power will not be provided. Tenant contractor must install permanent feeder conductors from the Landlord's service distribution point immediately for use as the source of light and power during construction. ® Any unused electrical equipment, conduit, wiring, etc within or serving the demised premises must be removed. ® Reuse of all or part of existing equipment is subject to the field verification of the capacity and condition of the components. Contract documents shall provide minimum performance parameters, refurbishing specifications and establish a verification procedure, including a mandatory written report. This report shall detail inspection and service to be performed, repair reporting procedures, additional recommendations, and performance test results. Copies of field verification report shall be submitted to the Landlord to validate reuse. PANELS ® Tenant shall provide service sizing calculation by filling out form on this drawing or other similar summary form. All calculations shall be per NEC. ® Tenant shall provide a detailed one -line diagram, depicting all existing conditions and new work to be performed. ® Tenant shall provide a main disconnect means within the leased space. ® Circuit breakers shall be bolt -on, not plug-in type. ® Arrange load to maintain a balance between phases of 10% or less. ® Tenant shall have breaker locks on control and timeclock circuits. ® Switching duty breakers on all devices used for turning loads on/off. ® 24-Hour/7-Day Time Clock is required to control storefront entry lights, show window lights, show window receptacles,and storefront signage. ® Electrical devices, time -clocks, panels, cabinets, etc. shall be mounted on a plywood backer -board. SIMON PROPERTY GROUP I NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 46207 317) 636-1600 CARMEL - 1N D1AN A GROUNDING ® Grounding must be to building steel with exothermic weld or split bolt connection. Do not ground to cold water pipe. TRANSFORMERS ® All transformers shall be 3 phase. Single phase transformers are not permitted. ® 30 KVA and smaller transformer may be suspended from Landlord's roof structure. ® Mount transformer on vibration isolators. CONDUIT AND WIRING ® All wiring must be in conduit. All conduits shall be concealed where possible. ® Flexible conduit shall be MC only. ® Flexible conduit is not permitted within demising walls. ® Exposed conduit shall be installed in straight lines, parallel with or at right angles to the building structure. Do not loop excess flexible conduit in ceiling space. ® Wire shall be copper THHN or THWN with insulation. ® All wiring shall be color coded per the mall's current labeling standard, or as follows: 208/120 volt systems: 277/480 volt systems: Phase A - Black Phase A - Brown Phase B - Red Phase B - Orange Phase C - Blue Phase C - Yellow Neutral - White Neutral - White with tracer or gray HVAC WIRING ® Tenant shall provide a main disconnecting means at each HVAC unit. ® Rooftop units and exhaust fans, if required, are to be wired through their roof curbs if so designed, or utilize factory fabricated roof piping curbs. Pitch pockets are not permitted. ® A 110 volt, duplex outlet shall be installed within reach of the HVAC unit. SERVICE ACCESS ® All electrical work shall be installed so as to be readily accessible for operating, servicing, maintaining and repairing. FLUORESCENT LIGHTING ® Exposed flourescent tubes or fixtures with paracube, or prismatic lenses are not permitted in public areas. Ballasts shall be high power factor, electronic with CBM ® or ETL label and have a THD of + 20%. ELECTRICAL LOAD SUMMARY NEC Connected NEC DEMAND I © 0 Description KVA AMPS MULTIPLIER KVA AMPS NOTES Lighting Tenant's Space Recessed 7.6 9.1 1.25 9.5 11.4 O Surface I 1.25 Fusible Switch or Track 9.9 11.9 150 VA/2FT 9.9 11.9 FO Sign 1.2 1.4 1.25 1.5 1.8 Receptacles 6.6 7.9 1.00 (1ST 10KW) 6.6 7.9 Water Heater 2.0 2.4 1.00 2.0 2.4 Air Handling Unit Fan Motor 3.9 4.7 1.00 3.9 4.7 Electric Heat 50.0 60.1 1.00 50.0 60.1 Misc. Equip. (fans, etc.) 1.00 25% of Largest Motor 1.00 TOTAL 81.2 97.6 83.4 100.2 ALL VALUES ON THIS CALCULATION FORM ARE PER N.E.C. LIGHTING DEMAND K.W. FROM LOAD SUMMARY TO BE USED IN H.V.A.C. CALCULATIONS. O Wireway ..°-4 INDEX MEP -1 MECHANICAL CRITERIA DOCUMENT CHECKLISTS AND DETAILS. MEP -2 ELECTRICAL AND PLUMBING CRITERIA DOCUMENT CHECKLISTS AND DETAILS. MEP -3 SPECIALTY TENAT CRITERIA DOCUMENT CHECKLISTS AND DETAILS. (ONLY WHEN REQUIRED) Conduit by landlord wire by tenant. F -F Conduit with pullwire for tenant's communication connections. Conduit with pullwire for tenant's power connections. Fused disconnect switch. 'Meter, only where the Coordinate with field representative tenant is customer of for location relative to meter. the Utility Company. NOTE: 1. This detail is provided to identify some of the conditions found in the field. Tenant shall field verify actual conditions prior to submitting documents. 2. Location of existing service is to be determined by Tenant in the field. 3. Tenant shall obtain available fault current data from the utility company. Tenant's engineer shall specify appropriate AIC rating for tenant panel. Partial Riser Diagram PLUMBING GENERAL ® Tenant's drawings are to clearly show ALL modifications to existing installation that are required to accommodate Tenant improvements. ® Tenant improvement plumbing documents shall be prepared and stamped by a Registered Professional Engineer. ® This document is to be used as a checklist to verify compliance with Mall Design Criteria. ® Unless already existing and in compliance with Landlord's requirements. Tenant is required to install, upgrade and/or furnish any and all equipment, piping, etc. for Tenant's plumbing installation. ® The design, materials and installation shall conform to the best current practice in the respective trades and shall be consistent with good engineering practice, manufacturer's recommendations, industry technical references and standards. ® Any modification or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawing submission. Upgrades shall be subject to availability. ® Modifications to existing systems that are required to accommodate Tenant improvements shall be clearly defined in both in the written request for deviation and on the contract documents. ® Tenant shall provide sanitary/vent riser diagrams as well as water piping riser diagram on design drawings. ® Only one connection to the Landlord's sanitary and domestic water mains is permitted. ® Tenants shall connect to existing vent header if existing, or extend vents thru roof. All roofing work must be by Landlord's roofer at Tenant's expense. ® Domestic water is supplied at the pressure available from the utility minus piping pressure losses to the point of connection. Tenants requiring specific pressures should test the available pressure and install regulators or booster pump systems to meet their needs. ® Any unused plumbing equipment, ductwork, piping, wiring, etc within or serving the demised premises must be removed. FIRE PROTECTION GENERAL ® Tenant's drawings are to clearly show ALL modifications to existing installation that are required to accommodate Tenant improvements. ® Tenant improvement fire protection documents shall be prepared and stamped by a Certified Sprinkler Designer or Registered Professional Engineer. ® This document is to be used as a checklist to verify compliance with Mall Design Criteria. Unless already existing and in compliance with Landlord's requirements. Tenant is required to install, upgrade and/or furnish any and all equipment, piping, etc. for Tenant's fire protection installation. The design, materials and installation shall conform to the best current practice in the respective trades and shall be consistent with good engineering practice, manufacturer's recommendations, industry technical references and standards. Any modification or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawing submission. Upgrades shall be subject to availability. PIPING MATERIALS ® Below ground waste and vent shall be service -weight cast iron or schedule 40 PVC. All no -hub connections shall be with cast iron couplings, similar to "MG" couplings including tie in to Landlord main. Stainless steel band no -hub connections are not permitted below ground. ® Above ground waste shall be service weight cast iron. Above ground vent shall be cast iron or Schedule 40 galvanized steel. PVC piping is not permitted above ground. ® Below ground water shall be type "K" (soft) copper with no joints below ground. ® Above ground water shall be type "L" copper. LOCATION of PIPING ® All plumbing equipment shall be properly suspended from Landlord's structure. All floor mounted equipment (water heaters, etc.) shall impose a floor load no greater than 75 psf. ® No sanitary, vent, water or gas piping will be permitted within the Demising Walls. ® Hinged access doors must be installed to provide access to all Plumbing equipment including but not limited to; valves, cleanouts, meters, and indirectly connected piping or as designated by the Landlord. PIPING COMPONENTS ® All connections to Landlord's cold water main is to include a service isolation valve. ® Any and all piping not reused, serving the demised premises must be removed. ® Insulate all hot water, cold water, and condensate drain piping. ® Tenants shall provide at least one, full size, cleanout in toilet and kitchen areas. Cleanout may be wall or floor type, but must be accessible from within the Tenant's space. ® One floor drain must be installed in toilet rooms and other locations that may be exposed to liquids, such as food service areas. ® All floor drains must have trap primers. ® Interceptors and separators shall be provided to prevent the discharge of oil, grease, hair, coffee granules and other substances harmful to the building's drainage system. Refer to Criteria Drawing MEP -3 for further requirements. Modifications to existing systems that are required to accommodate Tenant improvements shall be clearly defined in both in the written request for deviation and on the contract documents. Only one connection to the Landlord's fire protection main is permitted. Any unused fire protection equipment, piping, etc within or serving the demised premises must be removed. Reuse of all or part of existing equipment is subject to the field verification of the capacity and condition of the components. Contract documents shall provide minimum performance parameters, refurbishing specifications and establish a verification procedure, including a mandatory written report. This report shall detail inspection and service to be performed, repair reporting procedures, additional recommendations, and performance test results. Copies of field verification report shall be submitted to the Landlord to validate reuse. 02/07/04 CONTACT INFO ELECTRICAUPLUMBING CRITERIA For questions regarding site access, storefront & REVISED ON: 6/10/04 architectural criteria, engineering design, delivery dates, construction rules & regulations, the scope of Landlord's Standard Checklist and Tenant's work and store opening requirements, please contact your Tenant Coordinator or call 317-636-1600 for assistance. WATERPROOF MEMBRANE ® If the Premises concrete slab is not on grade, Tenant shall install a waterproofing barrier membrane, in accordance with Landlord's specifications, in all areas that may be exposed to fluids or liquids including, but not limited to, restrooms, food preparation and service areas, laundry and dry cleaning areas, and photo processing areas. All floor pipe penetrations, cleanouts, and floor drains must be sealed watertight, with membrane and flashing extended into clamping collar, per manufacturer's specifications. Refer to Architectural Criteria. WATER HEATERS ® Storage type water heaters shall be installed with relief valves and drain pans discharging to a floor drain. ® Instantaneous water heaters are only acceptable if they do not substantially impact the Tenant's electrical service. ® All water heaters 3KW and larger shall be 3 phase. ® Shock absorbers, thermal expansion tanks, and vacuum breakers shall be provided in accordance with good engineering practices. ® Natural gas water heaters are not permitted except where written approval from Landlord has been granted Prior to drawing submission. WATER METERS ® Where tenant is not a customer of the utility company, all Food Tenants and other heavy water users shall provide a Rockwell or equal, utility grade water meter to be both directly read and indirectly read via remote reader. ® Metering assembly to be properly located and adequately supported to allow for easy reading, maintenance, repair and replacement. ® The meter and checks shall be accessible for maintenance and reading without removing the device from the line. ® Where tenant is not a customer of the utility company a double check valve assembly is required. GAS SERVICE (where available) ® Tenant is responsible for coordinating available capacity, pressure, service connection, and meter installation with the Landlord and the local utility. ® All piping shall be finished with a rust inhibitive primer, color coded finish, and identification labels. ® Gas meter by tenant at tenant's expense, install per utility company requirements. Simon Property Group requires all tenants to use SimplexGrinnell for all fire protection work. Tenant or Tenant's General Contractor is required to contract with (and pay for) all tenant sprinkler work directly with SimplexGrinnell. For pricing and scheduling call SimplexGrinnell Representative @800-299-4377 (ext. 8488). All shut -downs must be scheduled with Landlord Representative. Fire protection system shall be charged and operable when contractor's not on site. Sprinkler heads to be quick response type rated for 165F. CLAY TERRACE 14311 Clay Terrace Boulevard Cannel, Indiana 46032 MEP -21 O� 0 I © 0 � Metered Switchboard M O I tl © Tenant's Space a O al I O Fusible Switch or O ® 01 1 0 011 Breaker FO 71-0 11 Finished Grade. I� -I AV Fused disconnect switch. 'Meter, only where the Coordinate with field representative tenant is customer of for location relative to meter. the Utility Company. NOTE: 1. This detail is provided to identify some of the conditions found in the field. Tenant shall field verify actual conditions prior to submitting documents. 2. Location of existing service is to be determined by Tenant in the field. 3. Tenant shall obtain available fault current data from the utility company. Tenant's engineer shall specify appropriate AIC rating for tenant panel. Partial Riser Diagram PLUMBING GENERAL ® Tenant's drawings are to clearly show ALL modifications to existing installation that are required to accommodate Tenant improvements. ® Tenant improvement plumbing documents shall be prepared and stamped by a Registered Professional Engineer. ® This document is to be used as a checklist to verify compliance with Mall Design Criteria. ® Unless already existing and in compliance with Landlord's requirements. Tenant is required to install, upgrade and/or furnish any and all equipment, piping, etc. for Tenant's plumbing installation. ® The design, materials and installation shall conform to the best current practice in the respective trades and shall be consistent with good engineering practice, manufacturer's recommendations, industry technical references and standards. ® Any modification or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawing submission. Upgrades shall be subject to availability. ® Modifications to existing systems that are required to accommodate Tenant improvements shall be clearly defined in both in the written request for deviation and on the contract documents. ® Tenant shall provide sanitary/vent riser diagrams as well as water piping riser diagram on design drawings. ® Only one connection to the Landlord's sanitary and domestic water mains is permitted. ® Tenants shall connect to existing vent header if existing, or extend vents thru roof. All roofing work must be by Landlord's roofer at Tenant's expense. ® Domestic water is supplied at the pressure available from the utility minus piping pressure losses to the point of connection. Tenants requiring specific pressures should test the available pressure and install regulators or booster pump systems to meet their needs. ® Any unused plumbing equipment, ductwork, piping, wiring, etc within or serving the demised premises must be removed. FIRE PROTECTION GENERAL ® Tenant's drawings are to clearly show ALL modifications to existing installation that are required to accommodate Tenant improvements. ® Tenant improvement fire protection documents shall be prepared and stamped by a Certified Sprinkler Designer or Registered Professional Engineer. ® This document is to be used as a checklist to verify compliance with Mall Design Criteria. Unless already existing and in compliance with Landlord's requirements. Tenant is required to install, upgrade and/or furnish any and all equipment, piping, etc. for Tenant's fire protection installation. The design, materials and installation shall conform to the best current practice in the respective trades and shall be consistent with good engineering practice, manufacturer's recommendations, industry technical references and standards. Any modification or upgrade of existing base building services or construction must receive the prior written approval from the Landlord, prior to drawing submission. Upgrades shall be subject to availability. PIPING MATERIALS ® Below ground waste and vent shall be service -weight cast iron or schedule 40 PVC. All no -hub connections shall be with cast iron couplings, similar to "MG" couplings including tie in to Landlord main. Stainless steel band no -hub connections are not permitted below ground. ® Above ground waste shall be service weight cast iron. Above ground vent shall be cast iron or Schedule 40 galvanized steel. PVC piping is not permitted above ground. ® Below ground water shall be type "K" (soft) copper with no joints below ground. ® Above ground water shall be type "L" copper. LOCATION of PIPING ® All plumbing equipment shall be properly suspended from Landlord's structure. All floor mounted equipment (water heaters, etc.) shall impose a floor load no greater than 75 psf. ® No sanitary, vent, water or gas piping will be permitted within the Demising Walls. ® Hinged access doors must be installed to provide access to all Plumbing equipment including but not limited to; valves, cleanouts, meters, and indirectly connected piping or as designated by the Landlord. PIPING COMPONENTS ® All connections to Landlord's cold water main is to include a service isolation valve. ® Any and all piping not reused, serving the demised premises must be removed. ® Insulate all hot water, cold water, and condensate drain piping. ® Tenants shall provide at least one, full size, cleanout in toilet and kitchen areas. Cleanout may be wall or floor type, but must be accessible from within the Tenant's space. ® One floor drain must be installed in toilet rooms and other locations that may be exposed to liquids, such as food service areas. ® All floor drains must have trap primers. ® Interceptors and separators shall be provided to prevent the discharge of oil, grease, hair, coffee granules and other substances harmful to the building's drainage system. Refer to Criteria Drawing MEP -3 for further requirements. Modifications to existing systems that are required to accommodate Tenant improvements shall be clearly defined in both in the written request for deviation and on the contract documents. Only one connection to the Landlord's fire protection main is permitted. Any unused fire protection equipment, piping, etc within or serving the demised premises must be removed. Reuse of all or part of existing equipment is subject to the field verification of the capacity and condition of the components. Contract documents shall provide minimum performance parameters, refurbishing specifications and establish a verification procedure, including a mandatory written report. This report shall detail inspection and service to be performed, repair reporting procedures, additional recommendations, and performance test results. Copies of field verification report shall be submitted to the Landlord to validate reuse. 02/07/04 CONTACT INFO ELECTRICAUPLUMBING CRITERIA For questions regarding site access, storefront & REVISED ON: 6/10/04 architectural criteria, engineering design, delivery dates, construction rules & regulations, the scope of Landlord's Standard Checklist and Tenant's work and store opening requirements, please contact your Tenant Coordinator or call 317-636-1600 for assistance. WATERPROOF MEMBRANE ® If the Premises concrete slab is not on grade, Tenant shall install a waterproofing barrier membrane, in accordance with Landlord's specifications, in all areas that may be exposed to fluids or liquids including, but not limited to, restrooms, food preparation and service areas, laundry and dry cleaning areas, and photo processing areas. All floor pipe penetrations, cleanouts, and floor drains must be sealed watertight, with membrane and flashing extended into clamping collar, per manufacturer's specifications. Refer to Architectural Criteria. WATER HEATERS ® Storage type water heaters shall be installed with relief valves and drain pans discharging to a floor drain. ® Instantaneous water heaters are only acceptable if they do not substantially impact the Tenant's electrical service. ® All water heaters 3KW and larger shall be 3 phase. ® Shock absorbers, thermal expansion tanks, and vacuum breakers shall be provided in accordance with good engineering practices. ® Natural gas water heaters are not permitted except where written approval from Landlord has been granted Prior to drawing submission. WATER METERS ® Where tenant is not a customer of the utility company, all Food Tenants and other heavy water users shall provide a Rockwell or equal, utility grade water meter to be both directly read and indirectly read via remote reader. ® Metering assembly to be properly located and adequately supported to allow for easy reading, maintenance, repair and replacement. ® The meter and checks shall be accessible for maintenance and reading without removing the device from the line. ® Where tenant is not a customer of the utility company a double check valve assembly is required. GAS SERVICE (where available) ® Tenant is responsible for coordinating available capacity, pressure, service connection, and meter installation with the Landlord and the local utility. ® All piping shall be finished with a rust inhibitive primer, color coded finish, and identification labels. ® Gas meter by tenant at tenant's expense, install per utility company requirements. Simon Property Group requires all tenants to use SimplexGrinnell for all fire protection work. Tenant or Tenant's General Contractor is required to contract with (and pay for) all tenant sprinkler work directly with SimplexGrinnell. For pricing and scheduling call SimplexGrinnell Representative @800-299-4377 (ext. 8488). All shut -downs must be scheduled with Landlord Representative. Fire protection system shall be charged and operable when contractor's not on site. Sprinkler heads to be quick response type rated for 165F. CLAY TERRACE 14311 Clay Terrace Boulevard Cannel, Indiana 46032 MEP -21 DIVISION 1 - GENERAL REQUIREMENTS SECTION 01010 - SUMMARY OF WORK 1.1 RELATED DOCUMENTS A. Drawings (including these Specifications) and general provisions of Owner -Contractor Agreement, including AIA Document A201 -General Conditions as modified by any Supplementary Conditions issued by the Owner, shall govern the Work. Specific information intended to be complimentary. B. Drawings and Specifications are inp may be found in either or both. Written dimensions hold preference over scaled dimensions. Do not scale drawings. 1.2 GENERAL A. General Contractor and each subcontractor must visit site to verify all conditions and dimensions before submitting bids. Prior to initial site visit, arrangements must be made with the Mall management. Report any discrepancies or any conditions which may interfere with the proper execution of the drawings to the Owner. Report discrepancies during bidding process and before start of construction. Extras will not be allowed for yob or code compliance conditions after commencement of construction. B. Owner has the right to select or reject any and all bids. C. General Contractor shall be responsible to coordinate and schedule with the Owner all Work on this project including Work under separate contracts with all Contractors to assure proper execution of the Work. Work shall be done in proper sequence and at proper time so as not to cause any delay in the progress of any trade or of entire project. D. Layouts of equipment, piping systems, duct and conduit runs, etc. are diagrammatic, unless specifically dimensioned. Each Contractor shall provide all necessary setting materials and accessories (hangers, bolts, trapeze materials, etc.) for a complete and sound installation. E. It shall be the full responsibility of the General Contractor to coordinate and expedite all phases of the Work of all trades for the entire project. The General Contractor and all Subcontractors shall provide for any and all overtime necessary to maintain the construction schedule. 1.3 CONTRACTOR USE OF PREMISES A. Contractor shall verify all conditions and criteria with Landlord's on-site coordinator, including the use of assigned loading docks, freight elevators, deliveries, storage, etc. The General Contractor shall be responsible for scheduling and all related fees. B. Contractor shall coordinate with Landlord's on-site coordinator for all work that is required to be done outside the lease line. Contractor is to be responsible for protecting the Landlord and Owner's Work and for any and all patching, cutting and repair that may be required. C. All contractors shall abide by the rules and regulations published by Landlord for conduct, including but not limited to, those pertaining to parking, toilet facilities, safety, delivery of materials and supplies, employee egress to the Center, and trash storage or collection or removal. The General Contractor and Owner's contractors are held responsible for the actions and behavior of all parties under their direction. 1.4 OWNER OCCUPANCY A. The Owner reserves the right to occupy and to place and install equipment in areas of the leased space, prior to Substantial Completion. Such placing of equipment and partial occupancy shall not constitute acceptance of the total Work. 1.5 OWNER FURNISHED ITEMS A. The Owner will provide items as shown on the Responsibility Schedule. The General Contractor's Work includes receiving, handling, protecting and installation of all items, unless noted otherwise. 1. The General Contractor will insect all deliveries for damage and notify Owner of any damages. If Owner -furnished items are damaged or missing, the Owner will arrange for replacement. 2. The Contractor is responsible for coordinating the delivery dates and for receiving and handling those items at the site. The Contractor is responsible for protecting Owner -furnished items from damage and to repair or replace items damaged as a result of his operations. 3. Contractor shall include the complete cost of the following: uncrating, disposal of crating & wrapping, installation, layout, labor, equipment, supervision & fasteners to install this Work, unless noted otherwise in the Responsibility Schedule, in a first class manner and of highest quality. 1.6 LANDLORD -FURNISHED ITEMS (if applicable) A. The General Contractor is responsible for coordinating directly with the Landlord for receiving, installation and all costs (if any) related to Landlord -furnished items. SECTION 01040 - PROJECT COORDINATION 1.1 COORDINATION A. It is the General Contractor's responsibility to provide supervision as required to work with subcontractors and Owner's subcontractors as one project team. 1. The General Contractor shall provide or rent all tools, welders, generators, fasteners, labor, equipment, supervision, inspections, permits, fees, etc. required for completing entire Project. 2. Provide supervision on day of and day after store turnover. 3. Provide for removal of Owner's subcontractor's refuse. B. Coordinate scheduling and timing to avoid conflicts and ensure orderly progress of the Work. 1.2 SUBMITTALS A. Subcontractors: Within 5 working days prior to commencement of construction, submit a list of all subcontractors' names, addresses, phone numbers, and contact person to Owner and Landlord. B. The General Contractor shall obtain and convey to Owner and Landlord all approvals, tests and inspections with respect to electrical, HVAC, plumbing and telephone work, all as may be required to any agency or utility company. 1.3 GENERAL INSTALLATION PROVISIONS A. The Contractor is responsible for the preparation of all substrates and related conditions required for all components. B. Comply with manufacturer's installation instructions and recommendations. C. Layout of Work: 1. General Contractor is to lay out Work and be responsible for all lines, measurements of the building, and other work executed under the Contract. 2. All dimensions given are from face of finish to face of finish, unless noted otherwise. D. Provide attachment and connection devices and methods necessary for securing Work. Secure Work true to line and level. Allow for expansion and building movement. E. Where mounting heights are not indicated, install individual components at standard mounting heights recognized within the industry for the particular application indicated, and in accordance with the Americans with Disabilities Act (ADA) and/or local code. as required for surface/built-in F. Provide all fire retardant wood and/or metal blocking q / devices, equipment, cabinets, accessories, fixtures, displays, etc. whether or not, the need for blocking is identified on the drawings. 1.4 GENERAL FLOORING INSTALLATION PROVISIONS A. Flooring Contractor is responsible for inspecting and verifying all field conditions of the leased space floor. B. Flooring Contractor must familiarize himself with all specified floor finishes, whether supplied and installed by the Contractor or the Owner's subcontractor, in order to properly prepare the substrate so as the top of all flooring materials align. 1. All floor finishes shall be installed flush in elevation alignment with each other per transition details, 2. Mall floor elevation shall align with store's entry finish floor. C. Topping Applied to Hardened Concrete (if applicable): 1. Prepare substrate surface per topping manufacturer's specifications. 2. Contractor MUST verify compatibility of floor leveling compound with finish flooring to be applied above it. ONLY install products as recommended by finish flooring manufacturer. D. Failure of topping to bond to substrate (evidenced by a hollow sound when tapped), or disintegration or other failure to perform, will be considered failure of materials and workmanship, Repair or replace in areas of such failures. 1.5 CLEANING AND PROTECTION A. General Contractor is responsible for all cleaning, including Landlord's requirements. B. Premises shall be kept "broom clean" at the completion of each work day. C. Contractor to provide 1/4" masonite protection over entire floor area as required to protect new finishes during construction, up to Substantial Completion. D. Contractor will be responsible for all labor, materials, dumpsters and/or fees, landfill fees and any dumping charges, equipment, and supervision to accomplish all debris removal off-site, including Owner's subcontractors. Contractor will be responsible for meeting all Landlord, local, state, and federal requirements for such dumping. SECTION 01095 - REFERENCE STANDARDS AND CODES 1.1 INDUSTRY STANDARDS A. Except where the Contract Documents include more stringent requirements, applicable construction industry standards have the same force and effect as if bound or copied directly into the Contract Documents to the extent referenced. Such standards are made a part of the Contract Documents by reference. B. Each entity engaged in construction on the Project is required to be familiar with industry standards applicable to its construction activity. 1.2 CODES A. All work, materials and installation shall be in strict accordance with all ordinances, state and local building codes, latest edition, the Americans with Disabilities Act (ADA), and follow all applicable Landlord requirements. B. Loads and code restrictions for all design considerations shall conform to the local and state codes, and all governing codes. C. The General Contractor shall obtain and pay for all required permits and inspections. D. The General Contractor is responsible for compliance with the provisions of the Occupational Safety and Health Act, latest edition. 1.3 SUBMITTALS A. Permits, Licenses, and Certificates: For the Owner's records, submit copies of permits, licenses, certifications, receipts for fee payments, and similar documents, correspondence, and records established in conjunction with compliance with standards and regulations bearing upon performance of the Work, and as required in the Contract. SECTION 01300 - SUBMITTALS 1.1 SUBMITTAL REQUIREMENTS A. Along with administrative submittals required in other Sections of the Specifications, Shop Drawing and Product Data submittals are required whenever existing site conditions Landlord criteria or the Contractor proposes or requires any modification of details, materials equipment or methods of construction from those shown in the Contract Documents The Contractor shall B. not proceed with Work that deviates from the Contract Documents before notifying the Owner of the possible modification and receiving approval from the Owner and Landlord if required. C. Submittals received from sources other than the Contractor will be returned without action. The General Contractor is responsible for all costs incurred in forwarding the submittals to the Owner, distribution to the subcontractors, and any submittal to the Landlord. D. The General Contractor will keep on-site a log of all submittals. E. Prepare a fully developed construction schedule. Submit within 5 days prior to the date for commencement of the Work. SECTION 01500 - TEMPORARY FACILITIES 1.1 SUMMARY A. General Contractor is responsible for all costs and actions for acquiring, installing and maintaining the temporary facilities needed on-site including but not limited to lighting, telephone (including fax machine), barricades, electrical service/usage and removal, drain down and re -filling of the fire sprinkler system, and ventilation including any Landlord requirements. Include costs for any fees, allowances, or Landlord charges. B. Comply with industry standards and applicable laws and regulations of authorities having jurisdiction. C. Provide barricades as required by Landlord's criteria. D. Install temporary lighting that will fulfill security and protection requirements, and will provide adequate illumination for construction operations (especially application of painting materials). E. Provide temporary telephone service with call waiting service, one telephone and one fax machine for all personnel engaged in construction activities. F. Collect waste daily. Comply with requirements of National Fire Protection Association (NFPA) 241 and Landlord's requirements. 1.2 TERMINATION AND REMOVAL A. Complete or, if necessary, restore permanent construction that may have been delayed because of interference with the temporary facility. 1. Materials and facilities that constitute temporary facilities are property of the Contractor. The Owner reserves the right to take possession of Project identification signs. 2. At Substantial Completion, clean and renovate permanent facilities that have been used during the construction period: a. Replace air filters and clean diffusers, inside of ductwork, and housings. b. Replace significantly worn parts and parts that have been subject to unusual operating conditions. C Replace lamps that are burned out or noticeably dimmed by substantial hours of use. SECTION 01700 - PROJECT CLOSEOUT 1.1 SUBSTANTIAL COMPLETION A. Submit specific warranties, workmanship bonds, maintenance agreements, final certifications and similar documents, and as required in the Contract Agreement. B. Submit a reproducible form of record drawings to the Landlord as required. Submit record drawings, maintenance manuals, and similar final record information to Owner. C. Deliver spare parts, extra stock, and similar items. D. Complete start-up testing of systems, and instruction of the Owner's operating and maintenance personnel. Discontinue or change over and remove temporary facilities from the site, along with construction tools, and similar elements. E. Complete final clean up requirements, including touch-up painting. Touch-up and otherwise repair and restore marred exposed finishes. F. Submit "Material Safety Data Sheets" to the Landlord and Building Code Officials (if applicable) for all composition construction materials (mastics, composition tile, etc.) certifying that those materials do not contain asbestos or other hazardous materials. 1.2 FINAL ACCEPTANCE A. Provide Owner with all Final Waiver of Liens from each entity. B. Submit the final payment request with releases not previously submitted and accepted, C. Submit a Certificate of Occupancy. D. General Contractor must provide Owner with a copy of the Landlord's Final Inspection report, showing proof that the Contractor has fulfilled all Landlord requirements. E. Provide "Tenant Contractor's Affidavit of Payment" as required by the Landlord. 1.3 CLOSEOUT PROCEDURES A. Arrange for each installer of equipment that requires regular maintenance to meet with the Owner's personnel to provide instruction in proper operation and maintenance 1.4 FINAL CLEANING A. Employ professional cleaners for final cleaning. Clean each surface or unit to the condition expected in a normal, commercial building cleaning and maintenance program. Comply with manufacturer's instructions, 1. Remove labels that are not permanent labels. 2. Clean transparent materials, including mirrors and glass in doors and windows. Remove glazing compound and other substances. Replace chipped or broken glass and other damaged materials. 3. Clean exposed hard -surfaced finishes to a dust -free condition, free of stains, films and similar foreign substances. Restore reflective surfaces to their original reflective condition. Vacuum carpeted surfaces. Mop clean all hard -surfaced floors or as recommended by manufacturer. 4. Wipe surfaces of mechanical and electrical equipment. Remove excess lubrication and other substances. Clean light fixtures and lamps. 5. Clean the site, of rubbish, litter and other foreign substances. Remove stains, spills and other foreign deposits. SECTION 01740 - WARRANTIES AND INSURANCE 1.1 WARRANTY REQUIREMENTS A. All Work shall be warranted for one (1) year after date of Substantial Completion. B. When correcting warranted Work that has failed, remove and replace other Work that has been damaged as a result of such failure or that must be removed and replaced to provide access for correction of warranted Work. C. When Work covered by a warranty has failed and been corrected by replacement or rebuilding, reinstate the warranty by written endorsement. The reinstated warranty shall be equal to the original warranty with an equitable adjustment for depreciation. D. Upon determination that Work covered by a warranty has failed, replace or rebuild the Work to an acceptable condition complying with requirements of Contract Documents. E. Manufacturer's disclaimers and limitations on product warranties do not relieve the Contractor of the warranty on the Work that incorporates the products, nor does it relieve suppliers, manufacturers, and subcontractors required to countersign special warranties with the Contractor. 1.2 INSURANCE A. The General Contractor is to secure, pay for and maintain for all periods of construction and fixturing Work within the premises, all of the insurance policies required and in the amounts as determined by Landlord or Owner requirements. Contractor shall not commence any Work until all required insurance has been obtained and certificates of such insurance have been delivered to Landlord and Owner. 1. All insurance policies required under this exhibit, except as noted above, shall include the Owner, its consultants, Architect, Landlord, and those entities listed on the lease as additional insured, except the worker's compensation insurance; further provided, said worker's compensation insurance shall contain an endorsement waiving all rights of subrogation against the Owner, Architect and Landlord. B. The following minimum coverage is required, verify with Landlord for required liability limits: 1. Workman's Compensation and Occupational Disease. 2. Commercial General Liability Insurance. 3. Comprehensive Automobile Liability Insurance. 4. Owner's and Contractor's Protective Liability Insurance. 5, Builder's Risk Insurance. C. Certificates of insurance shall provide that no reduction in the amounts or limits of liability or cancellation of such insurance coverage shall be undertaken without prior 30 day written notice to Landlord, Owner, Architect and L.L.'s required additional insureds. DIVISION 5 - METALS SECTION 05521 - PIPE / TUBE SYSTEMS 1.1 PERFORMANCE REQUIREMENTS AND SUBMITTALS A. Engineer, fabricate, and install systems to withstand the following structural loads without exceeding the allowable design working stress of the materials for anchors, and connections. B. Control of Corrosion: Prevent galvanic action and other forms of corrosion by insulating metals and other materials from direct contact with incompatible materials. 1.2 METALS A. Provide metals free from surface blemishes where exposed to view in the finished unit. Exposed -to -view surfaces exhibiting pitting, seam marks, roller marks, stains, discolorations, or other imperfections on finished units are not acceptable. B. The display system, handrails, floor fixtures (benches, etc.) shall be constructed from standard weight (schedule 40), black finish, iron pipe with malleable cast iron, slip-on, threadless pipe fittings conforming to American Society for Testing and Materials (ASTM) A47-77-32510 as regularly supplied by Kee Industrial Products, Inc., Buffalo, NY (800) 851-5181. 1. All fittings shall be secured to the pipe by zinc plated set screws with a case hardened cup point. The minimum outside diameter of the set screws shall be .650" O.D. with a nominal I.D. pipe size of 1-1/2". 1.3 FASTENERS, AND ANCHOR'S A. Select fasteners of the type, grade, and class required to produce connections that are suitable for anchoring pipe to other types of construction indicated and capable of withstanding design loadings. Provide exposed fasteners for interconnecting components and their attachment to other work. 1.4 INSTALLATION, GENERAL A. Install system per manufacturer's specifications and instructions. B. Fabricate systems to comply with requirements indicated for design, dimensions, details, finish, member sizes, spacings, and anchorage, but not less than those required to support structural loads. C. Provide manufacturer's standard wall brackets, flanges, miscellaneous fittings, and anchors to interconnect tubing system members to other construction. D. Mount system on gypsum board assemblies only where reinforced to receive anchors and where the location of concealed reinforcements has been clearly marked. E. Fit exposed connections accurately together to form tight joints. F. Set systems accurately in location, alignment, and elevation, measured from established lines and levels and free from rack. 1. Set posts plumb within a tolerance of 1/4 inch in 12 feet. 2. Align rails so that variations from level for horizontal members do not exceed 1/4 inch in 12 feet. G. Provide anchorage devices and fasteners where necessary for securing tubing systems to in-place construction. H. Protect finishes of systems from damage during construction period with temporary protective coverings approved by manufacturer. Remove protective coverings at time of Substantial Completion. DIVISION 6 - WOOD AND PLASTICS SECTION 06105 - MISCELLANEOUS CARPENTRY 1.1 LUMBER, GENERAL A. Furnish lumber manufactured to comply with Product Standard of NBS (U.S. Dept. of Commerce) PS 20 "American Softwood Lumber Standard" and with grading rules of inspection agencies certified by American Lumber Standards Committee's (ALSC) Board of Review. B. Provide fire -retardant treated materials. C. Dressed lumber, S4S, unless otherwise indicated. D. S -DRY, KD 19 or MC 19 (19 percent maximum moisture content). E. No. 2 or standard grade, 2 Common, or Construction Boards. F. Electrical/Telephone Backing Panels: C -D Plugged, Exposure 1 plywood panels, fire -retardant treated, 3/4 inch nominal thickness. 1.2 INSTALLATION, GENERAL A. Install members plumb and true to line and level. B. Securely fasten miscellaneous carpentry as indicated and according to applicable codes and recognized standards. C. Countersink nail heads on exposed carpentry work and fill holes. D. Use fasteners of appropriate type and length. Pre -drill members when necessary to avoid splitting wood. E. Construction Panels: Comply with applicable installation recommendations in American Plywood Association (APA) Form E30 "Design/Construction Guide -Residential & Commercial." 1. Electrical/Telephone Backboards: Contractor shall verify and coordinate exact size and location of panels with Electrical Contractor and the existing conditions. DIVISION 8 - DOORS AND WINDOWS SECTION 08111 - STANDARD STEEL DOORS AND FRAMES 1.1 GENERAL A. Provide factory primed doors and frames to be field painted. B. Provide doors and frames complying with Steel Door Institute (SDI) "Recommended Specifications Standard Steel Doors and Frames" American National Standards Institute (ANSI) ANSI/SDI-100 and as herein specified. C. Fire -Rated Door Assemblies: Units that comply with NFPA 80, are identical to door and frame assemblies whose fire resistance characteristics have been determined per ASTM E 152 and which are labeled and listed by UL, or other testing and inspecting organization acceptable to authorities having jurisdiction. 1.2 MATERIALS AND FRAMES A. Cold -Rolled Steel Sheets: Commercial quality carbon steel, complying with ASTM A 366 and ASTM A 568. B. Supports and Anchors: Fabricate of not less than 18 -gage sheet steel. C. Inserts. Bolts, and Fasteners: Manufacturer's standard units. D. Shop Applied Paint: Apply after fabrication. 1. Primer: Rust -inhibitive, suitable for specified paints complying with ANSI A224.1. E. Provide metal frames for doors as shown on drawings and schedules. Conceal fastenings, unless otherwise indicated. Fabricate frames of minimum 18 -gage cold -rolled steel. F. Door Silencers: Drill stops to receive 3 silencers on strike jamb. 1.3 FABRICATION AND INSTALLATION A. Fabricate frames, stiffeners, reinforcement, and edge channels, from cold -rolled steel. B. Locate hardware in accordance with "Recommended Locations for Builder's Hardware on Std Steel Doors & Frames," published by Door & Hardware Institute (DHI), or per code. C. Apply shop coat of prime paint of even consistency to provide a uniformly finished surface ready to receive finish paint. D. Check and readjust operating hardware items, leaving doors and frames undamaged and in complete and proper operating condition. SECTION 08211 - FLUSH WOOD DOORS 1.1 QUALITY ASSURANCE AND WARRANTY A. Quality Standards: Comply with the following standards: 1. I.S.1 "Industry Standard for Wood Flush Doors", of National Wood Window and Door Association (NWWDA). 2. "Architectural Woodwork Quality Standards"; including Section 1300 "Architectural Flush Doors", of Architectural Woodwork Institute (AWI) for grade of door, finish and other requirements exceeding those of NWWDA quality standard. B. Provide doors which are identical in materials and construction to units tested in door and frame assemblies per ASTM E 152 and which are labeled and listed for ratings indicated by UL, or other testing and inspection agency acceptable to authorities having jurisdiction. C. Provide written warranty in door manufacturer's standard form signed by Manufacturer, Installer and Contractor, agreeing to repair or replace defective doors that have warped (bow or twist) or that show telegraphing of core construction in face veneers, or do not conform to tolerance limitations of referenced quality standards. 1.2 INTERIOR FLUSH WOOD DOORS A. Solid Core Doors for Opaque Finish: Comply with the following requirements: 1. Faces: Any closed -grain hardwood of mill option. AWI Grade: Custom. B. Shop prime exposed portions of doors with one coat of wood primer. 1.3 INSTALLATION AND PROTECTION A. Install wood doors to comply with manufacturer's instructions and of referenced d AWI standard and as indicated. 1. Install fire -rated doors in corresponding fire -rated frames in accordance with requirements of NFPA No. 80. B. Protect doors as recommended by manufacturer to ensure that doors will be without damage or deterioration at time of Substantial Completion. SECTION 08305- ACCESS DOORS 1.1 QUALITY ASSURANCE A. Fire -Rated Door Assemblies (if applicable): Provide units that comply with NFPA 80, are identical to door and frame assemblies tested for fire -test -response characteristics per test method as indicated below, and are labeled and listed by UL, or other testing and inspecting agency acceptable to authorities having jurisdiction. 1. Test Method for Vertical Installations: ASTM E 152. 2. Test Method for Horizontal Installations: ASTM E 119. 1.2 MATERIALS - Provide trimless, flush access doors for gypsum board as required. A. Steel: 14 gauge door and 14 gauge mounting frame both with factory applied prime coat of grey baked enamel. B. Door: Flush to edge of frame. C. Frame/Flange: Galvanized steel drywall taping bead on all sides with prepunched holes. D. Hinge: Continuous, concealed. E. Latch: Screwdriver -operated cam latch. F. Manufacturer: Acudor #DW -5040 (for non -fire -rated applications), or equal. 1.3 INSTALLATION A. Preparation: Advise installers of other work about specific requirements relating to access door installation, including sizes of openings to receive access door and frame, as well as locations of supports, inserts, and anchoring devices. Furnish inserts and anchoring devices for access doors that must be built into other construction. B. Comply with manufacturer's instructions for installing access doors. C. Install concealed -frame access doors flush with adjacent finish surfaces. D. Adjust hardware and panels after installation for proper operation. E. Remove and replace panels or frames that are warped, bowed, or otherwise damaged. SECTION 08410 - ALUMINUM ENTRANCES AND STOREFRONTS 1.1 SYSTEM PERFORMANCE REQUIREMENTS A. Provide aluminum entrance and storefront assemblies that comply with performance characteristics specified, as demonstrated by testing the manufacturer's corresponding stock assemblies according to test methods indicated. B. Thermal Movement: Design the aluminum entrance and storefront framing systems to provide for expansion and contraction of the component materials. Entrance doors shall function normally over the specified temperature range. 1. The system shall be capable of withstanding a metal surface temperature range of 200 degrees without buckling, failure of joint seals, undue stress on structural elements, damaging loads on fasteners, reduction of performance, stress on glass, or other detrimental effects. C. Provide storefront systems that comply with structural performance, air infiltration, and water penetration requirements indicated. 1. Wind loads: Provide assemblies capable of withstanding wind pressures of 20 psf inward and 20 psf outward acting normal to the plane of the wall. 2. Conduct tests for structural performance in accordance with ASTM E 330. There shall be no glass breakage or permanent damage to fasteners, anchors, hardware or actuating mechanism. Framing members shall have no permanent deformation in excess of 0.2 percent of their clear span. Deflection Normal to the Plane of the Wall: Test pressure required to measure deflection shall be equivalent to the wind load specified above. Deflection shall not exceed 1/360 of the clear span, when subjected to uniform load deflection test. b. Deflection Parallel to the Plane of the Wall: Test pressures required to measure deflection parallel to the plane of the wall shall be equal to 1.5 times the winci pressures . Deflection of any member carrying its full dead load shall not exceed an amount that will reduce glass bite below 75% of the design dimension and shall not reduce the edge clearance to less than 1/8 inch. The clearance between the member and an operable door shall be at least 1/16 inch. 3. Provide system with an air infiltration rate of not more than 0.06 CFM per sq. Ft. of fixed area (excluding operable door edges) when tested in accordance with ASTM E 283 at an inward test pressure differential of 1.57 psf. 4. Provide systems with no uncontrolled water penetration as defined in the test method when tested in accordance with ASTM E 331 at an inward test pressure differential of 6.24 Ibf per sq. ft. 5. Provide systems that have an overall U -value of not more than 0.65 BTU at 15 mph exterior wind velocity when tested in accordance with AAMA 1503. 1.2 SUBMITTALS A. Provide product data for the storefront system including recommendations for maintenance and cleaning of surfaces. B. Provide shop drawings for the storefront system including the following: layout and installation details, including relationship to adjacent work; elevations; detail sections of typical composite members; anchors and reinforcement; hardware mounting heights; provisions for expansion and contraction; and glazing details. C. Provide samples of each specified color and finish on 12 inch long sections of extrusions or formed shapes. 1.3 QUALITY ASSURANCE, PROJECT CONDITIONS AND WARRANTY A. Provide aluminum entrances and storefront systems produced by a firm experienced in manufacturing systems that are similar to those indicated for this project and that have a record of successful in service performance. B. Check openings by accurate field measurement before fabrication. Show recorded measurements on shop drawings. Coordinate fabrication schedule with construction progress to avoid delay of the work. C. Submit a written warranty, executed by the manufacturer, agreeing to repair or replace units that fail in materials or workmanship for a period of three years after Substantial Completion. Failures include, but are not necessarily limited to: structural failure including excessive deflection, excessive leakage or air infiltration; faulty operation; deterioration of metals, metal finishes and other materials beyond normal weathering. 1.4 MANUFACTURERS A. Subject to compliance with requirement, manufactures offering entrance and storefront systems that may be incorporated in the work include, but are not limited to, the following: Amarlite Architectural Products, Dawson Metal Company, Inc., EFCO Corporation, Kawneer Company, Inc. , United States Aluminum Corp., and Vistawall Architectural Products, 1,5 MATERIALS A. Aluminum members: Alloy and temper recommended by the manufacturer for strength, corrosion resistance, and application of required finish; comply with ASTM B 221 for aluminum extrusions, ASTM B 209 for aluminum sheet or plate, and ASTM B 211 for aluminum bars, rods and wire. B. Comply with requirements of "Glazing" section of these specifications. C. Fasteners: Provide fasteners of aluminum, nonmagnetic stainless steel, zinc plated steel, or other material warranted by the manufacturer to be noncorrosive and compatible with aluminum components, hardware, anchors and other components. D. Concealed Flashina: 0.026 inch thick minimum extruded aluminum of alloy and type selected by manufacturer for compatibility with other components. E. Concrete and masonry inserts: Provide cast iron, malleable iron, or hot -dip galvanized steel inserts complying with ASTM A123, F. Compression weatherstrip ing: Manufacturer's standard replaceable compressible weatherstripping gaskets of molded neoprene complying with ASTM D 2000 or molded PVC complying with ASTM D 2287. 1.6 HARDWARE A. Refer also to Door Schedule on Cover Sheet. B. Provide heavy-duty hardware units as scheduled or required for operation of each door, including the following items of sizes, number, and type recommended by manufacturer for service required; finish to match door. C. Offset Pivot Sets: Comply with ANSI A156.4, Grade 1. Provide exposed parts of cast aluminum alloy. Provide an intermediate pivot for doors over 7 feet 6 inches high. D. Surface -Mounted Overhead Closers: Modern type with cover, for hinge side installation. Comply with ANSI A156.4, Grade 1. Comply with manufacturer's recommendations for closer size, depending on door size, exposure to weather and anticipated frequency of use. Include Delayed action closing. E. Door -mounted Holder: Flip -up type door -mounted holder with rubber shoe for mounting on lower rail, comply with ANSI A156.16, Grade 1. F. Door stop: Floor- or wall -mounted door stop, as appropriate, with integral rubber bumper; comply with ANSI A156.16, Grade 1. G. Cylinders: Mortise type, 6 -pin tumbler, with cast aluminum face for keying into store system. H. Deadlocks: Mortised maximum security deadlock, with minimum 1 inch long pivoted bolt and stainless steel strike box; comply with ANSI A156.5, Grade 1. I. Edge mortised automatic flushbolts at top and bottom of the inactive leaf of pair of doors; use in combination with single point, center -mounted deadlock in the active leaf, concealed rod mechanism in the lock stile of the inactive leaf, two-stage locking of both leaves and one -stage unlocking of both leaves by actuation of deadlock. J. Pull Handles: Aluminum pull handles of style indicated. K. Push Bars: Aluminum push bars of style indicated. L. Threshold: Extruded aluminum threshold of size and design indicated (flush alignment with adjacent entrance mat) in clear mill finish to match storefront system, complete with anchors and clips, coordinated with pivots. 1.7 COMPONENTS A. Provide storefront and entrance framing systems fabricated from extruded aluminum members of size and profile indicated. Include subframes and other reinforcing members of the type indicated. Provide for flush glazing storefront from the exterior on all sides without projecting stops. Shop fabricate and preassemble frame components where possible. Provide storefront frame sections without exposed seams. B. Stile and Rail Type Entrance Doors: Provide tubular frame members, fabricated with mechanical joints using heavy inserted reinforcing plates and concealed tie -rods or j -bolts. 1. Fabricate doors to facilitate ate re la cement of lass or Panels without di s asse mbl Y of stiles and rails. Provide snap -on extruded aluminum glazing stops, with exterior stops anchored for nonremoval. 2. Design: Provide 1-3/4 inch thick doors with medium stile. 1.8 FABRICATION A. Complete fabrication, assembly, finishing, hardware application, and other work to the greatest extent possible before shipment to the Project site. Disassemble components only as necessary for shipment and installation, B. Separate dissimilar metals with bituminous paint, or a suitable sealant, or a nonabsorptive plastic or elastomeric tape, or a gasket between the surfaces. Do not use coatings containing lead. C. Maintain accurate relation of planes and angles with hairline fit of contacting members. D. Conceal fasteners wherever possible. E. For exterior doors, provide compression weatherstripping against fixed stops. At other edges, provide sliding weatherstripping retained in adjustable strip mortised into door edge, Provide EPDM or vinyl -blade gasket weatherstripping in bottom door rail, adjustable for contact with threshold. 1,9 FINISHES A. Comply with NAAMM "Metal Finishes Manual" for recommendations relative to application and designations of finishes. B. Class II Clear Anodized Finish: Mechanical Finish: as fabricated, nonspecular; Chemical Finish: etched, medium matte; Anodic Coating: Class II Architectural, clear film thicker than 0.4 mil) complying with AAMA 607.1. 2.0 INSTALLATION A. Comply with manufacturer's instructions and recommendations for installation. B. Adjust operating hardware to function properly, for smooth operation without binding, and for weathertight closure. C. Clean the complete system, inside and out, promptly after installation, exercising care to aboid damage to coatings. SECTION 08710 - DOOR HARDWARE 1,1 HINGES, LATCHES, CLOSERS AND PLATES A. Provide only template -produced hinge units. B. Except as otherwise indicated, provide hinge pins as follows: 1. Interior Doors: Non -rising pins, 2. Tips: Flat button and matching plug, finished to match leaves. C. Provide not less than 3 hinges per door leaf for doors 90 inches or less in height and one additional hinge for each 30 inches of additional height. D. Provide manufacturer's standard wrought box strike for each latch bolt, with curved lip extended to protect frame, finished to match hardware set, E. Closers shall comply with ANSI A117.1, for door opening force and delayed action closing. F. Fabricate brushed aluminum, (U.S. 18 gage) protection plates not more than 1-1/2 inches less than door width on both sides, by height indicated. 1.2 INSTALLATION A. Mount hardware units at heights indicated by DHI, except as specifically indicated or required to comply with governing regulations. B. Install each hardware item in compliance with the manufacturer's instructions and recommendations. Do not install surface -mounted items until finishes have been completed on the substrates involved. C. Set threshold in full bed of sealant. D. Adjust each operating item to ensure proper operation or function. 1. During the week prior to occupancy, make final check and adjustment of all N C WY 04 95 MANN & MAN A R C H I T E C T S I N 3801 S CAPITAL OF TEXAS H SUITE 330 AUSTIN TX 787 TEC: 512.912.7994 FAX: 512.912.79 rJUL 1 2 laid �.,,N`'�.� 1E �A 4,74'.. ` ,,, v ., ....... ,, �` el- ' ' _ , W -7 i -a STATE OF ' '. '. ,4DIAd� �Z, �` a . 0 i H �„ ,1I�itE�> ,v All drawings, specifications, and designs © Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR ^" Fiffrois ��ne a www.ffnishitne.com CLAY TERRACE CARMEL, 1N SPACE #B 16 SPECIFICATIONS MWA #4084 FINL STORE A l #708 s2 N C WY 04 95 items. Clean items as necessary to restore proper function and finish. SECTION 08800 - GLAZING 1.1 SYSTEM PERFORMANCE REQUIREMENTS A. Provide glazing systems that are produced, fabricated, and installed to withstand normal movement and loading without failure including loss attributable to: defective manufacture, fabrication, and installation; failure of sealants or gaskets; deterioration of glazing materials; and other defects in construction. B. Glass thicknesses indicated are for detailing only. Confirm glass thicknesses by analyzing Project loads and in-service conditions. C. Comply with published recommendations of glass manufacturer and Flat Glass Marketing Association (FGMA) Publications. 1.2 PRODUCTS A. Heat -Treated Float Glass: Uncoated, Clear, Heat -Treated Float Glass: ASTM C 1048, Condition A (uncoated surfaces), Type I (transparent glass, flat), Class 1 (clear), Quality q3 (glazing select), kind FT (fully tempered) where indicated. 1, Ease and polish all edges. B. Cleaners, Primers and Sealers: Type recommended by sealant or gasket manufacturer. C. Setting Blocks: Elastomeric material with a Shore A durometer hardness of 85, t5. D. Silicone: Continuous black material to limit glass lateral movement at head and sill condition. Provide clean, smooth, tooled joint. E. Clips: Low profile glass clips (black finish) to stabilize glazing system. Locate at each vertical joint at storefront. 1.3 FABRICATION AND INSTALLATION A. Fabricate glass and other glazing products in sizes required to glaze openings indicated, with edge and face clearances, edge and surface conditions, and bite complying with recommendations of product manufacturer and referenced glazing standard as required. B. Comply with combined recommendations of manufacturers except where more stringent requirements are indicated, including those in referenced glazing publications. C. Install setting blocks, sized and located to comply with referenced glazing standard, unless otherwise required by glass manufacturer. Set blocks in thin course of compatible sealant suitable for heel bead. D. Remove nonpermanent labels, and clean surfaces. E. Provide glazing labels designating the type and thickness of glass as required by code. DIVISION 9 - FINISHES SECTION 09255 - GYPSUM BOARD ASSEMBLIES PART 1 - GENERAL AND PRODUCTS - The Contractor is solely responsible for the engineering , design and installation of all framing and gypsum board assemblies as required. 1.1 DEFINITIONS AND QUALITY ASSURANCE A. Refer to ASTM C 11 and GA -505 for definitions of terms. B. Where fire -rated gypsum board assemblies are indicated, provide materials and construction identical to those tested per ASTM E 119. C. All conditions noted as existing are based on the best information currently available at the time of preparation of these drawings. The Contractor is to verify all conditions before starting work. Should conditions arise which are different from those shown on the drawings, the Architect shall be notified immediately and additonal drawings based on more accurate information will be prepared. D. It is the Contractor's sole responsibility to determine erection procedure and sequence and insure the safety of the builindg and its component parts during erection. This includes the addition of whatever shoring, temporary bracing, etc. That may be necessary. Such material shall remain the Contractor's property after completion of the project. 1.2 STEEL FRAMING COMPONENTS FOR CEILINGS AND PARTITIONS A. Provide components complying with ASTM C 754 for materials, sizes and spacings unless otherwise indicated. B. Wire for Hangers and Ties: ASTM A 641, as required by local code or ceiling grid suspension manufacturer, 1.2 gauge minimum. C. Channels: Cold -rolled steel, 0.05980 inch minimum thickness of base (uncoated) metal and 7/16 inch wide flanges, D. Steel Studs and Runners: ASTM C 645, with flange edges bent back 90 degrees and doubled over to form 3/16 -inch minimum lip (return). All steel studs shall be manufactured by Cemco per ICBO Report 3403. Use 362ECS20 studs at 16" o.c. throughout unless noted otherwise, All tracks shall be 362SLT18 unless noted otherwise and shall be screwed to each stud with 1-#8 sheet metal screw to each flange unless noted otherwise. E. Steel Ceiling Track: Flex Track System, SFT Series, by Delta Star, Inc. 800-368-3017, or equal. Track operates as a slip joint, by means of "V" shapes on the sides of the track that "give" when pressure is applied, preventing cracking due to deflection. E. Steel Rigid Furring Channels: ASTM C 645, hat -shaped, depth of 7/8 inch. F. Fasteners for Metal Framing: Provide fasteners of type, material, size, corrosion resistance, holding power, and other properties as required; complying with the recommendations of gypsum board manufacturer. G. Grid Suspension System for Gypsum Board Interior Ceilings: ASTM C635, C636, C645, and C754. Manufacturer's standard heavy duty direct -hung double -web grid suspension system composed of main beams and cross furring members that interlock to form a modular supporting network for the screw attachment of gypsum board. System shall be "Donn Rigid X Drywall Suspension System" by USG, or approved equal. All materials and fabrication techniques shall be followed as specified by the manufacturer. The Contractor is solely responsible for the engineering, design and installation of the complete system. H. All electrodes shall be E60XX. Since the stresses in the welds are less than one-half of the allowable, field welding need not be inspected. I. All threaded rod shall conform to ASTM A307. J. All shot pins shall be Hilti DNP 8 pins (.145" diameter shank x minimum 1-1/2" long) with 14 gauge washers installed per ICBO Report 2388, 1.3 GYPSUM BOARD PRODUCTS A. Provide in maximum lengths available to minimize end-to-end butt joints. B. Gypsum Wallboard: ASTM C 36, Type X, 5/8 inch thick. Provide water-resistant gypsum board at all wet locations. Use multiple layers of less thick gypsum board to achieve flexibility as required at certain locations. 1.4 ACCESSORIES, JOINT TREATMENT, AND MISCELLANEOUS MATERIALS A. Corner beads, edge trim, and control joints complying with ASTM C 1047 and requirements indicated below: 1. Cornerbead on outside corners, unless otherwise indicated, #103 by USG Corp. 2. L -bead #200-B by USG Corporation. B. Provide joint treatment materials complying with ASTM C 475 and the recommendations of the manufacturer. C. Texture Finish Products: 1. Primer: Of type recommended by manufacturer, 2. Orange Peel Finish: Factory -packaged joint compound mixed with water at Project site for spray application to produce a light -spatter finish texture. a. Submit sample for approval. PART 2 - EXECUTION 2.1 INSTALLING STEEL FRAMING, GENERAL A. Install steel framing to comply with ASTM C 754 and with ASTM C 840. B. Install framing, blocking, and bracing to support fixtures, furnishings, or similar construction. Comply with details indicated and with recommendations of gypsum board manufacturer or with "Gypsum Construction Handbook" published by USG. C. Isolate steel framing from building structure to prevent transfer of loading imposed by structural movement. D. All steel stud vertical members shall be 362ECS20 Cemco metal studs unless noted otherwise. Provide (3) #8 sheet metal screws at all intersections, unless noted otherwise. E. All steel stud horizontal members shall be 362ECS18 for spans 8 feet or more and 362ECS20 for spans less than 8 feet unless noted otherwise. Provide (3) #8 sheet metal screws at all intersections unless noted otherwise. F. All steel stud braces shown shall be 362ECS20 Cemco metal studs. G. Provide 18 gauge bridging at midspan of ceiling joists for spans over 6 feet long. Bridging not required with plywood or drywall on both sides of joists. H. Grid Suspension System: Install according to manufacturer's specifications, including lateral bracing as required. The Contractor is solely responsible for the engineering , design and installation of the complete system. 2.2 INSTALLING STEEL FRAMING FOR PARTITIONS A. Extend partition framing full height to structural supports, except where indicated otherwise. Cut studs 1/2 inch short of full height. Continue framing over frames for doors and openings and frame around ducts penetrating partitions above ceiling to provide support for gypsum board. 1. For fire -resistive -rated partitions required to extend to the underside of floor/roof decks, install framing as needed to support gypsum board closures needed to make partitions continuous. B. Install studs in sizes and at spacings indicated, but not less than that required by the referenced standard to comply with max, deflection and min. loading requirements. C. Frame door opening to comply with GA -219, and recommendations of manufacturer. Attach vertical studs at jambs with screws either directly to frame or to jamb anchor clips on frame; install runner track section at head and secure to jamb studs, 2.3 APPLYING AND FINISHING GYPSUM BOARD A. Install and finish gypsum panels to comply with ASTM C 840 and GA -216. B. Install panels to minimize the number of abutting end joints, C. Install edge trim where edge of gypsum panels would otherwise be exposed or semi -exposed. Provide type of flange formed to receive joint compound. D. Apply joint treatment at gypsum board joints (both directions); flanges of corner bead, edge trim, and control joints; fastener heads, surface defects, and elsewhere as required to prepare gypsum board surfaces for finish. 1. Skim coat surface as required at curving partitions. E. Texture Finish: Apply at gypsum board partitions in Sales Area which are to receive black paint finish. Prepare and apply primer to gypsum panels according to manufacturer's instructions. Mix and apply finish using powered spray equipment to produce a uniform non -directional texture matching approved samples, free of starved sports or other evidence of thin application or of application patterns. SECTION 09300 - TILE 1.1 GENERAL AND PRODUCTS A Contractor shall supply all tile, grout, leveling materials, and all related components and accessories for a complete installation. B. Tile shall be as indicated in the Finish Key (Cover Sheet) and shall conform to requirements of ANSI A137.1-1988. C. Setting Materials: Latex -Portland cement mortar, per ANSI A118.4, D. Grouting Materials: Polymer -modified grout per ANSI A118.6. 1. All grout between black and white tile shall be black, Mapei's Classic Collection, Ultra/Color #10 Black, or approved equal. (800)42-MAPEI. 2. All grout between black and black tile shall be black, Mapei's Classic Collection, Ultra/Color #10 Black, or approved equal. (800)42-MAPEI. 3. All grout between gray and white tile shall be gray, Mapei's Classic Collection, Ultra/Color #27 Silver, or approved equal. 4. All grout between black and gray tile shall be black, Mapei's Classic Collection, Ultra/Color #10 Black, or approved equal. (800)42-MAPEI. 5. All grout between white and white tile shall be gray, Mapei's Classic Collection, Ultra/Color #27 Silver, or approved equal. 6. All grout between gray and gray tile shall be gray, Mapei's Classic Collection, Ultra/Color #27 Silver, or approved equal. 7. All grout at Landlord's tile shall match existing. E. Metal Edge Strips 1,2 INSTALLATION, GENERAL A. Acceptability of Surfaces: 1. Before tiling, verify that all surfaces to be tiled are true to plane and fall within maximum variations for floor leveling substrates as follows: 1/16" in 1'-0". 2. Do not tile such surfaces until they are leveled enough to meet above requirements. 3. Before tiling, all surfaces must be free of curing compounds, oil, grease, wax, dust or other substances that would interfere with proper bond of setting materials. B. Comply with all manufacturer's instructions for installation and grouting requirements and techniques. C. Setting Methods: Comply with parts of ANSI 108 series included under "Specifications for the Installation of Ceramic Tile" that apply to type of setting and grouting materials and methods as applicable. Comply with Tile Council of America, Inc. (TCI) "Handbook for Ceramic Tile Installation" for appropriate method of installation . 1. Press and beat tile into place to obtain 100% coverage. D. Accurately form intersections and returns. Perform cutting and drilling of tile without marring visible surfaces. Carefully grind cut edges of tile abutting trim, finish, or built-in items for straight aligned joints. 1. All tile joints at Sales Area shall be 1/8" joints. 2. At locations where vertical tile joints occur, corners shall be quirk mitered. E Unless otherwise shown, lay tile in grid pattern. Adjust to minimize tile cutting. Provide uniform joint widths unless otherwise shown. F. Grouting Methods: Follow exactly grout manufacturer's instructions and comply with ANSI A108.1. Grouting is not complete until all grout haze and residues are removed from the surface of the tile. G. Cleaning and protection: Leave finished installation free of cracked, chipped, unbonded or otherwise defective tile work, Clean all grout residue from finished work per manufacturer's specifications. 1. Provide final protection and maintain conditions that ensures that the is without staining, damage or deterioration. No foot or wheel traffic permitted on floor for at least 3 days after grouting. deterioration. No foot or wheel traffic permitted on floor for at least 3 days after grouting. SEC.'TION 09550 - WOOD FLOORING PART 1- GENERAL 1.1 SCOPE A. Furnish materials, labor, equipment, accessories and related items required to complete work indicated and/or specified per complete manufacturer's instructions. B. Work generally includes but is not limited to: preparation of surfaces, installation of flooring, finishing, protection, cleaning and buffing, and all items of related work reasonably inferred as needed to make work of this section complete. 1.2 QUALITY ASSURANCE, DELIVERY, STORAGE, AND HANDLING A. Engage an experienced installer who has specialized in installing types of wood flooring similar to those required for this Project. B. Protect wood flooring from exposure to moisture in shipment, storage, and handling. Deliver in unopened cartons or bundles and store in a dry place with adequate air circulation. Do not deliver material to building until concrete, masonry, tile, and other wet work is complete and cured to a condition of equilibrium and temperature and humidity are maintained at or near occupancy levels. 1.3 PROJECT CONDITIONS A. At time of delivery, average moisture content of wood flooring to be 6 to 9 percent, with a maximum of 12 percent for any one piece. B. Do not install wood flooring until spaces are enclosed and at approximate humidity condition planned for occupancy. A relative humidity of 35-55% should be provided before any installation is begun. Condition wood for 5 days before start of installation by placing in spaces to receive flooring and maintaining ambient temperature between 65 deg F and 75 deg F before, during, and after installation. Open sealed packages of wood flooring to permit natural adjustment of moisture content and allow flooring to acclimate to the room conditions. 1.4 WARRANTY A. Submit a written warranty executed by Manufacturer, Installer, and Contractor, agreeing to repair or replace wood flooring that fails in materials or workmanship within the specified warranty period. Failures include, but are not limited to: 1. Buckling, warping, squeaking, and loosening. 2. Excessive open joints or cracks. 3. Deterioration of finishes beyond normal wear. B. Warranty Period: 3 years from date of Substantial Completion. 1.5 EXTRA MATERIAL A. Deliver extra material to Owner. Before installation begins, furnish not less than 1.0 percent of the quantity of each type wood flooring installed on the Project, packaged with protective covering for storage and identified with labels clearly describing contents. PART 2 - PRODUCTS 2.1 WOOD STRIP FLOORING A. Maple Flooring: Where strip -type wood flooring is indicated, provide the following: 1. Species: 3 -ply laminated maple. See Finish Key. 2. Edges: Provide manufacturer's standard square top edge on faces. 3 Thickness: 3/8 inch. 4 Face Width: 3 inches. 5 Lengths: Provide std. random length strips (2'-12'). 2.2 ACCESSORY MATERIALS A. Moisture Barrier: Polyethylene sheeting conforming to ASTM D 4397, not less than 6.0 mils thick. Economical non -textured, matte finish (not gloss) vinyl sheet flooring glued to existing concrete slab may be used as a moisture barrier as recommended by wood flooring manufacturer. Only use if installation is warranted by flooring manufacturer. B. Fasteners: As recommended by manufacturer, but not less than that recommended by MFMA or NOFMA. C. Cork Expansion Strip: Composition cork expansion strip FS HH -C-576, Type I -B, Class 2. D. Wood Trim: Where indicated to match wood flooring, provide wood baseboard molding, shoe molding, and stair risers and treads of same species and grade as wood flooring. Except as otherwise indicated, provide wood stripping, reducer strips, nosings, saddles, thresholds, and other wood accessories indicated in or adjacent to wood flooring of same species, grade, and cut as wood flooring, E. Wood Base Molding: 1/2" x 2-1/4" maple wood molding to match wood flooring. PART 3 - EXECUTION 3.1 PREPARATION A. Where direct application of wood flooring to concrete substrate is indicated, test for dryness with calcium chloride test before proceeding with installation. Moisture content of concrete cannot exceed 2.5% by weight. It is essential that calcium chloride tests be taken on all concrete Moors regardless of age or arade level per manufacturer's specifications B. Check levelness of concrete substrate to ensure not more than 1/4 inch deviation in any direction when checked with a 10 foot straight edge. Grind down high spots or fill in low spots to correct improper conditions. C. Apply moisture barrier over concrete substrate or subfloor ONLY if recommended by flooring manufacturer. 3.2 INSTALLATION A. Comply with MFMA instructions and recommendations, but not less than that recommended by the manufacturer. B. Laminated Wood Flooring Installation (maple): 1. Glue down maple flooring to substrate according to manufacturer's written specifications, using manufacturer's specified adhesive. C. Nail baseboard to wall and any other trim to baseboard rather than to flooring. 3.3 PROTECTION A. Protect installed wood flooring during remainder of construction period as described in Division 1 of these Specifications to prevent damage or deterioration. B. Prior to turning the floor over to the Owner, it shall be thoroughly cleaned by sweeping and dust mopping to remove all loose debris, followed by spray buffing as recommended by finish manufacturer. C'Routine maintenance should consist of daily sweeping, vacuuming or dry mopping. Never use water or water based cleaners on any wood floor. A damp cloth or sponge may be used to remove water soluble spots or to clean up spills when they occur. SECTION 09650 - RESILIENT FLOORING 1.1 QUALITY ASSURANCE, DELIVERY, STORAGE, AND HANDLING A. Engage an experienced installer who has specialized in installing types of flooring similar to those required for this Project. B. Store, protect, handle, install and maintain the flooring as per all manufacturer's specifications and recommendations. 1.2 PROJECT CONDITIONS A. Floors shall be smooth, flat, level, permanently dry, clean and free of all foreign material such as dust, paint, grease, oils, old adhesive residue, etc. B. Patch and repair minor cracks and other imperfections with manufacturer approved portland-base patching compounds. Do not install over Gypsum -based leveling or Batching compounds. C. It is essential that calcium chloride moisture tests and bond tests be taken on all concrete floors regardless of the age or grade level, per manufacturer's specifications. D. Prepare subfloor per manufacturer's instructions. For rubber flooring installation, subfloor surface shall be smooth and flat to the equivalent of 3/16 in. (4.8 mm) in 10 feet. 1.3 INSTALLATION/ CLEANING/ PROTECTION A. Strictly follow all manufacturer's specifications and instructions for installation and maintenance, including the use of only manufacturer's recommended adhesives and flooring finishes. B. Rubber flooring products are to be cut from sheet goods provided by General Contractor. Layout should be planned to minimize seams and waste at Youth Area. C. Strictly follow manufacturer's specifications and instructions for initial cleanup and maintenance, including cleaning and applying floor finish. 1. Immediately remove all adhesive residue from the surface of the flooring. 2. Immediately after installation is completed, initial maintenance procedures must be implemented per manufacturer's complete maintenance instructions. D. Protect installed flooring during remainder of construction period against damage per these Specifications, Section 01040 -Project Coordination, Item 1.5 -Cleaning & Protection. Rubber flooring is not precoated with a factory finish, special care must be taken to protect flooring from construction traffic and debris until the final finish is complete. E. Rubber flooring finish shall be as recommended by manufacturer: 'Diversey-Lever Maintenance Products and Procedures for ECOsurfaces.' Provide TASKI vision matte (formerly ombra) satin finish polyurethane. All products and procedures as recommended by manufacturer shall be strictly followed for Initial Cleaning, Initial Floor Finish Application, Daily/Regular Cleaning, Interim Maintenance, Restorative Maintenance and Heavy Soil procedures if required. F. At Project Closeout, provide Owner with Daily/Regular and long term maintenance instructions for the care of the flooring. SECTION 09678 - RESILIENT WALL BASE AND ACCESSORIES General Contractor shall provide and install all wall base, transition strips and miscellaneous accessories as indicated or required per manufacturer's specifications and instructions. SECTION 09680 - CARPET 1.1 EXTRA MATERIALS AND MANUFACTURERS A. Deliver extra materials to Owner. Furnish materials packaged with protective covering for storage and identified with labels describing contents. B. Carpet: Supplied by Owner, installed by General Contractor, see Finish Schedule. 1.2 ACCESSORIES A. Carpet Adhesive: Water resistant and nonstaining as recommended by manufacturer to comply with flammability requirements for installed carpet. 1.3 PREPARATION A. Clear away debris and scrape up cementitious deposits from concrete surfaces to receive carpet. B. Patch holes and level to a smooth surface. If previous finish chemically stripped, reseal concrete. Seal powdery or porous surfaces with sealer recommended by carpet manufacturer, 1.4 INSTALLATION A. Comply with manufacturer's recommendations for recommended adhesives and all installation instructions. Follow manufacturer's Mandatory Pre -Installation Moisture and ph Testing Guidelines before installation. Install carpet tile in a random installation pattern. Do not bridge building expansion joints with continuous carpet. B. Extend carpet under removable flanges and furnishings. C. Provide cutouts where required, and bind cut edges where not concealed by protective edge guards or overlapping flanges. D. Install carpet by cutting tiles in a method recommended by the manufacturer. Provide sufficient strength for continued stresses during life of carpet. E. Fit sections of carpet prior to application of adhesive. G. Apply adhesive uniformly to substrate in accordance with manufacturer's instructions. Butt edges tight to form seams without gaps. 1,5 CLEANING AND PROTECTION A. Remove adhesive with manufacturer's recommended cleaning agent. B, Remove and dispose of debris. Vacuum, as recommended. Remove soil. Replace carpet where soil cannot be removed. C. Provide final protection as directed in Division 1. SECTION 09900 - PAINTING 1.1 SUMMARY A. Paint exposed surfaces whether or not colors are designated in schedules, except where a surface or material is specifically indicated not to be painted or is to remain natural. Where an item or surface is not specifically mentioned, paint the same as similar adjacent materials or surfaces. If color or finish is not designated, the Owner will select from standard colors or finishes available. 1. Painting includes field -painting gypsum board assemblies, door frames, exposed bare and covered pipes and ducts, hangers, conduits, exposed steel work, exposed fireproofing, and metal surfaces of mechanical and electrical equipment, including speakers and diffusers located in gypsum board assemblies. 2. Labels: Do not paint over Underwriters Laboratories, or other code -required labels or equipment name, identification, or nomenclature plates. 3. The store name and space designation number shall be clearly painted in black letters on the service door for identification. 1,2 PAINT MATERIALS, GENERAL A. Provide primers, finish coat materials, and related materials that are compatible with one another and the substrates indicated as demonstrated by the manufacturer. B. Provide the manufacturer's best -quality trade sale paint material of the various coating types specified, that are compatible with the substrate and finish coats indicated. C. Provide colors as indicated on the Finish Schedule. D. Provide clear concrete sealer for application indicated. Prepare, install, and protect as per manufacturer's specifications. 1.3 PRIMERS A. Subject to compliance with requirements, provide: 1. Gypsum Drywall Primer: Latex -based primer. a. Benjamin Moore: Latex Quick -Dry Prime Seal #201. 2, Ferrous Metal Primers: Synthetic, quick -drying. 1.4 PREPARATION A. Remove items already installed that are not to be painted, or provide surface -applied protection prior to painting. Following completion of painting operations, have items reinstalled by workers skilled in the trades involved. B. Before applying paint, clean the substrates. Schedule cleaning and painting so dust and other contaminants from the cleaning process will not fall on newly painted surfaces. 1.5 APPLICATION A. Apply paint according to manufacturer's directions. Use applicators and techniques best suited for substrate and type of material being applied. B. Do not paint over conditions detrimental to formation of a durable paint film. 1. The term exposed surfaces includes areas visible when permanent or built-in fixtures, grilles, and similar components are in place. 2. Paint surfaces behind movable equipment the same as similar exposed surfaces. Before the final installation of equipment, paint surfaces behind permanently fixed equipment with prime coat only. 3. Paint interior surfaces of ducts, where visible through registers or grilles, with a flat black paint. 4. Paint back sides of access panels and removable or hinged covers to match exposed surfaces. 5. Finish doors on tops, bottoms, and side edges same as faces. C. Apply materials no thinner than the manufacturer's recommended spreading rate. Provide the total dry film thickness of the entire system as recommended by the manufacturer. D. Completely cover to provide a smooth, opaque surface of uniform finish, color, appearance, and coverage. Cloudiness, spotting, laps, brush marks, runs, sags, or other surface imperfections will not be acceptable. 1.6 PROTECTION A. Protect work of other trades. Correct damage by cleaning, repairing or replacing, and repainting, as acceptable to Owner. B. At completion of construction activities of other trades, touch up and restore damaged or defaced painted surfaces. DIVISION 10 - SPECIALTIES SECTION 10425 - SIGNS PART 1 - GENERAL 1.1 QUALITY ASSURANCE AND PROJECT CONDITIONS A. Provide lighting fixtures and electrical components for illuminated signs that are labeled and listed by UL and comply with applicable National Electrical Manufacturers Association (NEMA) standards. B, Design Concept: The Drawings indicate sizes, profiles, and dimensional requirements. Other sign construction details may be considered provided deviations in dimensions and profiles do not change the design concept as judged by the Owner, The burden of proof of equality is on the proposer. 1. Logo: Contractor shall coordinate with Owner for Owner supplied and vendor artwork as required. C. Engineering: Provide all engineering and coordination required to provide a complete installation of the design concept including transformer sizing, location, electrical feeds, fit of all internal components within fabrication of other trades, access panels, etc. Engineering shall plan for future maintenance, durability and access. D. Field Measurements: Take field measurements prior to preparation of shop drawings and fabrication to ensure proper fitting. PART 2 - PRODUCTS 2.1 MATERIALS AND FINISHES A. Sign Box: Provide aluminum sheet of alloy and temper recommended by the sign manufacturer for the type of use and finish indicated, and with not less than the strength and durability properties specified in ASTM B 209 for 5005-H15. Include internal bracing for stability and attachment of mounting accessories. B. Push -Through Letters with metal face: Fabricate letters to required sizes and styles. Form exposed faces and sides of characters to produce surfaces free from warp and distortion. 1. Illuminate sign using manufacturer's standard lighting components. Make provisions for servicing and concealed connection to the building system. C. Non -illuminated Letters: Fabricate letters to required sizes and styles, Letters may be formed from sign foam, except at Cash Wrap, where metal is required. Form exposed faces and sides of characters to produce surfaces free from warp and distortion. D. Calors and Surface Textures: Provide color matches indicated, or if not indicated, as selected by the Owner from the manufacturer's standards. E. Comply with National Association of Architectural Metal Manufacturers (NAAMM) "Metal Finishes Manual" for finish designations and applications recommendations. PART 3 - EXECUTION 3.1 INSTALLATION, CLEANING AND PROTECTION A. Locate sign units and accessories where indicated, using mounting methods of the type described and in compliance with the manufacturer's instructions. 1. Install signs level, plumb, and at the height indicated, with sign surfaces free from distortion or other defects in appearance. B. General Contractor shall provide and install all wood and/or steel anchorage required to support all signage. Coordinate requirements with sign contractor. C. Provide and install signage at Toilet Room and at all other areas as required by the ADA and all local codes. D. After installation, clean soiled sign surfaces according to the manufacturer's instructions or to like -new condition. Protect units from damage until acceptance by the Owner. SECTION 10522 - FIRE EXTINGUISHERS Provide and install all fire extinguishers as required. SECTION 10800 - TOILET ACCESSORIES PROVIDE THE FOLLOWING IF NOT EXISTING. 1.1 PROJECT CONDITIONS AND MATERIALS A. General Contractor shall provide and install all toilet accessories as listed below. 1. General Contractor shall be responsible for verifying compliance with all state and local codes, and proper working condition of all items. B. (1) Surface -mounted paper towel dispenser (for rolled paper towels). Mount bottom of unit at 38" above finished floor, adjacent to lavatory, C (1) Surface -mounted toilet paper holder. Mount unit on the side wall 18" above finished floor and 36" from the rear wall. D (1) Surface -mounted mirror 16" wide by 36" high by Bobrick, or equal. Mount bottom of unit at 38" above finished floor centered directly above wall mounted lavatory. Mirror shall be 36" high, therefore top of mirror shall be 74" above finished floor. E (1) 1-1/2" diameter, surface -mounted grab bar with concealed mounting #B6206.99 x 42" by Bobrick, or equal. Mount on side wall (adjacent to handicap accessible toilet) 33" above finished floor, 12" from back wall. F (1) 1-1/2" diameter, surface -mounted grab bar with concealed mounting #86206.99 x 36" by Bobrick, or equal. Mount on back wall, 33" above finished floor, 12" minimum each side of handicap accessible toilet centerline, 1.2 INSTALLATION A. Install toilet accessory units according to manufacturers' instructions, using fasteners appropriate to substrate as recommended by manufacturer. Install units plumb and level, firmly anchored in locations and at heights indicated. B. Install grab bars to withstand a downward load of at least 250 Ibf, complying with ASTM F 446. C. General Contractor is responsible for providing and installing all blocking required for a complete and sound installation. D. Adjust toilet accessories for proper operation and verify that mechanisms function smoothly. Replace damaged or defective items. E. Clean and polish all exposed surfaces strictly according to manufacturer's recommendations after removing temporary labels and protective coatings. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL SPECIFICATIONS A 0111 MANN & MAMM A R C H I T E C T S ► N I 3801 S CAPITA! OF TEXAS HW SUITE 330 AUSTIN TX 7870 TEt:512.912.799.4 FAX:512.912.799 PiUL 1 2 2'GO4 Ny, . °��tiG`S 'v� FQ 7 S�jTATE r09F '..AIDIA41�, .•' �,-• Q �q�, •.... " ��\N I ,,-9�H1TrEC1,,\ .1.0i All drawings, specifications, and designs O Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR Finis "na Aflnishitne.com CLAY TERRACE CARMEL, IN SPACE #B 16 SPECIFICATIONS M&MA #4084 F#7L8STORE A1.3 FIRE & SI JTS. l/DECK CONT. 18 GA. TRACK W/2-#8 SMS @ JOIST, TYP. 18 TO SPAN BETWEEN (E) STRUCTURAL f t MEMBERS. CONNECT TO BEAM OR TOP '1-r'- CHORD OF BAR JOI� ATTACH PLATE W/ 0.140" DIS POWDER -DRIVEN FASTENERS 36" O.C. MIN. W/ 3/4" MIN. EMBEDALL NEW A 1 CONDITIONS A2 ONE HOUR RATED NOT RATED ASSEMBLY UL DESIGN #U465 [-(18 To SPAN BETWEEN (E) STRUCTURAL CONT. 18 GA. TRACK W/248 SMS @ JOIST, TYP. 3 Cir. rr)NSTRIIC-TI0N A3 NOT RATED t t MEMBERS. CONNECT Tr) BEAM OR TOP DRD OF BAR JOIST. B/DECK B/DECK )NT. 18 GA. SCK W/2-#8 LS @ JOIST, TYP.EXIST'G OR NEW EXIST'G C.M.U. 3 BY OTHERS PARTITION, VERIFY h THICKNESS & EXIST'G CONSTRUCTION IN 3 (TENANT SIDE) FIELD. _L1 20 EXIST'G MTL. STUD, VERIFY GA. & SPACING IN FIELD C E E2 NOT RATED ONE HOUR RATED ASSEMBLY UL DESIGN #0465 6 WAIL SECTIONS NOTE: ALL EXISTING TENANT SEPARATIONS TO BE MAINTAINED. NO CONNECTION TO ROOF DECK ALLOWED. SCALE: 1 " = 1'-0" FASTEN TRACK TO MTL. STUDS AND NOT ROOF DECK. - - - - - - - MIN. 3 1/2" MTL. STUD NESTED INTO THE FLUTES OF THE DECK SPANNING BETWEEN JOISTS TO LATERALLY SUPPORT TOP OF PARTITION, BEND TO FIT DECK FLUTES. PROVIDE CLEATS AT EACH END TO PREVENT SHIFTING. 18 GA. SUPPORT WIRE TO - - _ - - BOTTOM CHORD OF ROOF JOIST @ EACH POINT WHERE BULKHEAD INTERSECTS JOIST, TYP. 83 @ MID SPAN, TYP. 20 W/248 SMS AT TOP, TYP. - - 3 ;moo i� VARIES i B/YOUTH BULKHEAD 4 YOUTH BULKHEAD R_M Department Usable Fixture Area Net Sales Area PARTITION TYPE SYMBOLS MEN 318 sq. ft CORNER BEAD, TYP. 1,004 sq. ft o EXISTING MTL. STUD PARTITION - (1) HR. RATING @ ALL DEMISING WALLS WOMEN 285 sq. ft TYP (3) S8 629 sq. ft FIRE EXTINGUISHER: 2A/1 OBC RATING. YOUTH 189 sq. ft Ilk 547s ft NEW PARTITION Total Net Sales Area GRAPHICS SNAP FRAME @ 43 1/8" A.F.F. 2,180 sq. ft KEYNOTES Total Gross Sales Area SHELF, 24" WIDE 3,296 sq. ft • THE SYMBOL IS THE Total Gross Exit Corridor Area ELEC DATA STUB -UP (1 TOTAL) 110 sq. ft • VERIFY ALL CABINET EQ. EQ. Total Gross Stockroom Area P2. 1,598 sq. ft NOTE: Total Gross Floor Area ALL DIMENSIONS ARE 5,004 sq. ft FACE OF FULL STOCKROOM SHELVING (5 SHLVS.) Z 2 POS FWD - CASH WRAP NORTH Unit Total Quantity Prs. Shoes/Unit Prs. of Shoes (10' high) (5 shlvs./unit) 12x48 5 - - 12x48 61 100 6,100 12x36 16 80 1,280 24x48 14 200 2,800 24x36 2 160 320 Obstructed 1 -25 -25 Total Prs. of Shoes 10,475 AUDIO SYSTEM NOTES GENERAL CONTRACTOR TO PROVIDE THE FOLLOWING: 1. NON-COMBUSTIBLE WOOD OR METAL BLOCKING NEEDS TO BE IN PLACE BEFORE GYPSUM BOARD IS INSTALLED. 2. PROVIDE 3/4" CONDUIT TO RUN IN PARTITION FROM BEHIND ELECTRONICS RACK TO CASHWRAP FOR VOLUME CONTROL. LEAVE PULL STRING IN CONDUIT. 3. MOUNT ONE SINGLE DEEP J -BOX AT CASHWRAP FOR VOLUME CONTROL. 4. STOCKROOM VOLUME CONTROL: • PROVIDE 3/4" CONDUIT TO RUN IN WALL FROM BEHIND ELECTRONICS RACK TO MANAGER'S OFFICE FOR STOCKROOM'S 10 WATT VOLUME CONTROL. LEAVE PULL STRING IN CONDUIT. • MOUNT SINGLE DEEP J -BOX ADJACENT TO LIGHT SWITCH IN MANAGER'S OFFICE FOR STOCKROOM VOLUME CONTROL. S. MOUNT EMPTY SINGLE J -BOX @ 68" A.F.F. IN MANAGER'S OFFICE ABOVE DESK, STUB TO ABOVE CEILING NEAR DECK/STRUCTURE. LOCATE ADJACENT TO FLUSH MOUNTED 20 AMP DUPLEX OUTLET (ABOVE DESK @ 68" A.F.F.). PLAYNETWORK TO PROVIDE THE FOLLOWING: 1. PLAYNETWORK SYSTEM ELECTRONICS AND WIRE CONNECTIONSTO BE INSTALLED BY A PLAYNETWORK CERTIFIED SOUND CONTRACTOR. 2. SYSTEM ELECTRONICS RACK TO BE MOUNTED IN STOCKROOM, ADJACENT TO ELECTRICAL EQUIPMENT. 3. CENTER OF PLAYNETWORK SYSTEM ELECTRONICS RACK SHALL BE MOUNTED 94" A.F.F. IN STOCKROOM. 4. REFER ANY QUESTIONS TO DAVID PARKER, AT PLAYNETWORK, 1.888.567.PLAY(7529), EXT. 238. 3 1 AREAS, QUANTITIES, & MISC. NOTES CP SPACE #B16 5,004 SF I I I � N I � I r 30'-8" 42'-4" M 5 LANDLORD'S LEASE OUTLINE DRAWING m I NOT TO SCALE FIRE/SMOKE B/STRUCTURE STOPPING PARTITION TYPE 'C' ABOVE FIRE -RATED ASSEMBLY 8'6" A.FF .. CLG. PARTITION TYPE 'E' 3 FIRE TAPE & SEAL ALL JTS. PER UL #U465 ADJACENT RETAIL EXIT '�- PARTITION TYPE 'Al' TENANT CORRIDOR STOCKROOM ONE HOUR RATED ASSEMBLY UL DESIGN #U465 4 EXIT CORRIDOR SECTION NOTE: ALL EXISTING TENANT SEPARATIONS TO BE MAINTAINED. SCALE: 1 " = 1'-0" NOTE: PROVIDE COM. CLEAR SILICONE JOINT AT HORIZ. & VERT. FACES. TOOL SEALANT TO NOMINAL SIZE. NO GAPS, BUBBLES OR EDGES TYP. 1 NOTE: SHELVING LAYOUT SHOWN IS FOR GENERAL CONFIGURATION AND REFERENCE ONLY, FINAL SHELVING DESIGN, SIZES, SPECIFICATIONS, USE, ENGINEERING, LAYOUT, BRACING, LOAD LIMITS, CALCULATIONS, ETC. BY OTHERS UNDER SEPARATE PERMIT, IF REQUIRED. B8 I I NEW FURRED -OPT PARTITION SHALL ENCU SE EXISTING CROSS BRACING, V.I.F. I LANDLORD TO PROVIDE (EXISTING) SERVICE/EXIT DOOR AND NICHE AT TENANT'S EXPENSE. REFER TO MALL CRITERIA MANUAL FOR LANDLORD SCOPE OF WORK. B9 MALL EXTERIOR j (E) EXIT / SERVICE ENTRY I E I E' - (E) PIPE, V.I.F. I 2x36 N ELEC. (E) CROSS BRACING, V.I.F. N 12xaa � 2xea EXIT CORRIDOR --- _ }yaa NOTE: bo LOCATE AUDIO, SECURITY, / - 24xna - - - TELEPHONE AND DATA Zaxaa ` EQUIPMENT ABOVE DOOR OF w 24xaa zAxea 5` 1' I TOILET ROOM. CONTACT 40 24a I I ARCHITECT IF THERE ARE ANY 248 Zexaa I EXISTING CONDITIONS THAT PROVIDE A CONFLICT TO LOCATE THIS EQUIPMENT ABOVE TOILET ROOM DOOR. ' #05 ❑ V ' 01 RECEIVING 4i / M X 12x36 12x48 4 TOILET M +I N I M VESTIBULE % I i #02 4 - OFFICE 7 DRESSING ROOM M_ SH -1 SALES WALL co / ' MI88 t co N - I Ul I lI Ps FOS .- H I .-.----- -_-_- < >F o .0 "00 I CASH WRAPi I 4 OD O " I 18 (^ N Z \A 6'71 --------- E A6.1 I3'_q" mina w MEN 2 j YOUTH o �3'-9" min. ' 6'-1" A2.1 ( g N x r N 1 J N( C x Pl TYP. OF M W STOCKROOM A21 A4.1 Z _ 4 a- co ry °STOCKRC>OM B U1 3 1 j oI X_ A4.1 A4.1 j I TYP. 4 TYP. O, P3 f " Q � co P2 A4.1 I I I ^ I ADJACENT TENANT I U 1 P P4 j co I ADJACENT X -0 I -� �- T TENANT co �co 71 O I w� 6.110.H. h I °0 TYP. = I ; o I^ I X I ag �0 ^ I CO N 4-H MM I X X #� 03 F1 I ! #07 ^I 00 17 Ab.l MEN j WOMEN N I N I I N ; 0 P1 P. OF TYP. OF E " (5} (5)� �- r 00 O I O X g I g " c00o LU II MI ^ �Q r : i -Al t w LU N 0 00 O T- SHAPED WHEELCHAIR I -I - x ,I T SHAPED WHEELCHAIR TURNING SPACE I U l F ^ I I TURNING SPACE U1 QD N �I I I TYP. I TYP. 2x36 12x36 12x48 #01 l\ LEASE LINE ENTRY I APP REL ----------------------------- I LAYOUT i I 1 42'-8" PER SURVEY, V.I.F. I '-2" PER SURVEY V.I.F. SHOW WINDOW 'A' EXTERIOR SIDE WALK SHOW WINDOW 'B' 1 I FLOOR PLAN SCALE: 118" = 1'-0" FI MANN & MAMM A R C H I T E C T S / N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.912.7995 KEYNOTES 3. TYP. U 1 4. CORNER BEAD, TYP. 18, 3-5/8" 18 GA. MTL. STUD FRAMING, 16" O.C. 20. TYP (3) S8 �Iv �I FIRE EXTINGUISHER: 2A/1 OBC RATING. J 3'-0" OIL z Ilk VaQ GRAPHICS SNAP FRAME @ 30" A.F.F. 88. GRAPHICS SNAP FRAME @ 43 1/8" A.F.F. S I POS KEYNOTES 34" H 34" H SHELF, 24" WIDE COUNT I COUNTER • THE SYMBOL IS THE WM-24H ELEC DATA STUB -UP (1 TOTAL) 3'-2n • VERIFY ALL CABINET EQ. EQ. DIMENSIONS AND LAYOUT P2. • REFER TO SHOP DWGS. NOTE: • REFER TO ELEC DWGS, ALL DIMENSIONS ARE HANDICAP ACCESSIBLE COUNTER:TO FACE OF FULL TOP OF COUNTER IS 34" A.F.F., TYP. HEIGHT PARTITION, TYP. Z 2 POS FWD - CASH WRAP NORTH SCALE: 1/4" = 1'-0" NOTE: PROVIDE COM. CLEAR SILICONE JOINT AT HORIZ. & VERT. FACES. TOOL SEALANT TO NOMINAL SIZE. NO GAPS, BUBBLES OR EDGES TYP. 1 NOTE: SHELVING LAYOUT SHOWN IS FOR GENERAL CONFIGURATION AND REFERENCE ONLY, FINAL SHELVING DESIGN, SIZES, SPECIFICATIONS, USE, ENGINEERING, LAYOUT, BRACING, LOAD LIMITS, CALCULATIONS, ETC. BY OTHERS UNDER SEPARATE PERMIT, IF REQUIRED. B8 I I NEW FURRED -OPT PARTITION SHALL ENCU SE EXISTING CROSS BRACING, V.I.F. I LANDLORD TO PROVIDE (EXISTING) SERVICE/EXIT DOOR AND NICHE AT TENANT'S EXPENSE. REFER TO MALL CRITERIA MANUAL FOR LANDLORD SCOPE OF WORK. B9 MALL EXTERIOR j (E) EXIT / SERVICE ENTRY I E I E' - (E) PIPE, V.I.F. I 2x36 N ELEC. (E) CROSS BRACING, V.I.F. N 12xaa � 2xea EXIT CORRIDOR --- _ }yaa NOTE: bo LOCATE AUDIO, SECURITY, / - 24xna - - - TELEPHONE AND DATA Zaxaa ` EQUIPMENT ABOVE DOOR OF w 24xaa zAxea 5` 1' I TOILET ROOM. CONTACT 40 24a I I ARCHITECT IF THERE ARE ANY 248 Zexaa I EXISTING CONDITIONS THAT PROVIDE A CONFLICT TO LOCATE THIS EQUIPMENT ABOVE TOILET ROOM DOOR. ' #05 ❑ V ' 01 RECEIVING 4i / M X 12x36 12x48 4 TOILET M +I N I M VESTIBULE % I i #02 4 - OFFICE 7 DRESSING ROOM M_ SH -1 SALES WALL co / ' MI88 t co N - I Ul I lI Ps FOS .- H I .-.----- -_-_- < >F o .0 "00 I CASH WRAPi I 4 OD O " I 18 (^ N Z \A 6'71 --------- E A6.1 I3'_q" mina w MEN 2 j YOUTH o �3'-9" min. ' 6'-1" A2.1 ( g N x r N 1 J N( C x Pl TYP. OF M W STOCKROOM A21 A4.1 Z _ 4 a- co ry °STOCKRC>OM B U1 3 1 j oI X_ A4.1 A4.1 j I TYP. 4 TYP. O, P3 f " Q � co P2 A4.1 I I I ^ I ADJACENT TENANT I U 1 P P4 j co I ADJACENT X -0 I -� �- T TENANT co �co 71 O I w� 6.110.H. h I °0 TYP. = I ; o I^ I X I ag �0 ^ I CO N 4-H MM I X X #� 03 F1 I ! #07 ^I 00 17 Ab.l MEN j WOMEN N I N I I N ; 0 P1 P. OF TYP. OF E " (5} (5)� �- r 00 O I O X g I g " c00o LU II MI ^ �Q r : i -Al t w LU N 0 00 O T- SHAPED WHEELCHAIR I -I - x ,I T SHAPED WHEELCHAIR TURNING SPACE I U l F ^ I I TURNING SPACE U1 QD N �I I I TYP. I TYP. 2x36 12x36 12x48 #01 l\ LEASE LINE ENTRY I APP REL ----------------------------- I LAYOUT i I 1 42'-8" PER SURVEY, V.I.F. I '-2" PER SURVEY V.I.F. SHOW WINDOW 'A' EXTERIOR SIDE WALK SHOW WINDOW 'B' 1 I FLOOR PLAN SCALE: 118" = 1'-0" FI MANN & MAMM A R C H I T E C T S / N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.912.7995 KEYNOTES 3. 5/8" TYPE 'X' G. B., TYP. 4. CORNER BEAD, TYP. 18, 3-5/8" 18 GA. MTL. STUD FRAMING, 16" O.C. 20. 3-5/8" 20 GA. MTL. STUD FRAMING, 16" O.C. 60. FIRE EXTINGUISHER: 2A/1 OBC RATING. 83. 16 GA COLD ROLLED HORIZONTAL BRACING. 87. GRAPHICS SNAP FRAME @ 30" A.F.F. 88. GRAPHICS SNAP FRAME @ 43 1/8" A.F.F. MILLWORK KEYNOTES SH -1 SHELF, 24" WIDE WM-24W WALL MIRROR, 24" W, DIRECT WALL MOUNT WM-24H WALL MIRROR, 24" W, HANGRAIL MOUNT FIXTURE KEYNOTES P1. MEN'S SHOE PANEL P2. MEN'S MODULAR SHOE PANEL P3. WOMEN/ YOUTH SHOE PANEL P4. WOMEN'S MODULAR SHOE PANEL P5. INFANT SHOE PANEL U1. 2" X 2" METAL POST NOTE: REFER TO SHOP DRAWINGS FOR FURTHER FIXTURE INFORMATION JUL ? 2 2004 \�`,`1\lltllttlf +11!11,/ sIS7E Afi , 3W 87 TATE OF ';""0H l7E1-o"`9t All drawings, specifications, and desians © Mann & Mann Architects, Inc. 2004 _06_30.04 _ PERMIT, L.L. REVIEW, BID DATE ISSUED FOR FinisAL g-911"� ins► mnvw. com CLAY TERRACE CARMEL, tN SPACE #816 NORTH M&MA #4084 FINL STORE �� #708 0 ch TYP. R 1 {IN RANDOM PATTERN) WITHIN 0 CO TYP.R-2D2 N 9" 31-0" 31-0" 3'-0" �, 31-011 �911,, 0 c� Cl) 2 1 CASHWRAP FLOORING DETAIL NORTH SCALE: 1/4" = 1 `-0" VCT TRANSITION DETAIL VCT/WOOD HALF SCALE WOOD FLOORING WOOD FLOORING NOTE: ALIGN ALL FINISHES FLUSH TRANSITION DETAIL F WOOD/CARPET HALF SCALE WOOD FLOORING NOTE: ALIGN ALL FINISHES FLUSH TRANSITION DETAIL C WOOD/TILE HALF SCALE /8" GROUT JT. YP. ENANT TILE 32 CARPET RUBBER 31 NOTE: ALIGN ALL FINISHES FLUSH TRANSITION DETAIL H CARPET/RUBBER HALF SCALE E NOT USED HALF SCALE B NOT USED� WOOD FLOORING NOTE: ALIGN ALL FINISHES FLUSH TRANSITION DETAIL G WOOD/RUBBER HALF SCALE 1 /8" GROUT JT. P TENANT T NOTE: ALIGN ALL FINISHES FLUSH TRANSITION DETAIL D TILE/CARPET HALF SCALE ;ARPET A NOT USED mmmmft� HALF SCALE B8 B9 j MALL EXTERIOR (E) SEE DOOR SCHEDULE EXIT / SERVICE ENTRY FOR THRESHOLD rEXITCORRIDOR j VCT 1 j B-1 VCT -1 BASE TYP. PROVIDE MIN. 30 MIL. � j B-1 P6LYETHYLENE WATER - PR OF MEMBRANE TO RECEIVING BASE TYP. A IN. HEIGHT OF 5". I SEE DOOR SCHEDULE FOR THRESHOLD A2.2 TOILET VESTIBULE VCT -1 VCT 1 VCT -1 WF 1 OFFICE A2 2 B-1 B 2 B 2 DRESSING ROOM L7U G TYP. A2.2 i io$34 H I L YY j CASH RAP ALIGN CASH WRAP AND RUBBER j I H — j —� FLOORING WITH CENTERLINE OF MEN A2.2 _ ___ YOUTH GRAPHIC PANELS, GRAPHIC 2 PANEL 2. STOCKROOM A F i STOCKROOM B j A2.2 TYP. 10'-0" 10'-0" CPT -9 loj ADJACENT TENANT `�� 1 WF1 ADJACENT TENANT DIRECTION DIRECTION 'OF FLOOR' j OF FLOOR j ---� --- ------------------- -- - CBC CARPET TILE PATTERN SHALL BE PARALLEL TO EDGE OF WOOD FLOORING. CENTER CARPET TILE CONTRACTOR I I FINISH FLOOR PLAN SCALE: 1 /8 " = 1 '-0" NORTH MANN & MANN A R C H I T E C T S / N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.912.7995 KEYNOTES 31. FLOOR LEVELING AS REQ'D TO ALLOW FINISH FLOORING TO ALIGN FLUSH. 32. 1/4" W. ALUM. TERRAllO TYPE DIVIDER STRIP. "SCHLUTER-DECO" (HT. AS REQ'D FOR FLOORING) BY SCHLUTER SYSTEMS. 800.472.4588 75. ALUM. TRANSITION STRIP, "SCHLUTER-RENO-AEU" (HT. AS REQ'D FOR FLOORING) BY SCHLUTER SYSTEMS. FINISHES B-1 BLACK COVE BASE, 4" HIGH B-2 BLACK COVE BASE, 6" HIGH B-4 MAPLE BASE, 2" HIGH CPT -9 DARK GREY CARPET TILE CT -1 LANDLORD TILE CT -3 WHITE TILE CT -4 GRAY TILE R-1 BLACK MATRIX RUBBER R-2 GRAY MATRIX RUBBER R-3 BLUE MATRIX RUBBER R-4 BLUE/GRAY MATRIX RUBBER VCT -1 GRAY VINYL COMPOSITION TILE WF -1 MAPLE WOOD STRIP FLOORING FLOOR LEVELING NOTES: FLOAT TRANSITIONS BETWEEN ALL FLOOR FINISH MATERIALS TO ALIGN FLUSH. FEATHER THE CEMENTMOUS UNDERLAYMENT EVENLY W/ 1/16" VERTICAL CHANGE PER V-0" HORIZONTAL RUN MAXIMUM. REFER ALSO TO WRITTEN SPECIFICATIONS. ALL FLOOR FINISHES SHALL ALIGN FLUSH, UNLESS NOTED OTHERWISE. THERE SHALL BE NO FLOOR SURFACE CHANGE IN HEIGHT (INCLUDING THRESHOLDS) GREATER THAN 1/4". rJUL a' AR19'4C 7 srArF of All drawings, specifications, and designs O Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR Finis � ane CLAY TERRACE CARMEL, 1N SPACE #B 16 FINISH FLOOR PLAN M&MA #4084 FINL STORE #708 A2.2 {IN RANDOM PATTERN) WITHIN A2.2 THE SPACE TO ALLOW FOR THE LEAST AMOUNT OF WASTE. 2 MEN ENTRY WALK -OFF CPT. WOMEN SPECS SHALL BE PROVIDED BY TENANT. INSTALLED BY VCT -1 I WOOD FLOORING PATTERN B 1 CONTRACTOR B-1 SHOWN IS FOR GENERAL B-4 I B-4 LAYOUT AND DIRECTION ONLY. BASE TYP. ENTRY MAT. BASE TYP. STAGGER ALL JOINTS PER BASE, TYP. SPECS SHALL BE PROVIDED BY BASE, TYP. MFGR'S SPECIFICATIONS TYP. TENANT INSTALLED RY CONTRACTOR I I FINISH FLOOR PLAN SCALE: 1 /8 " = 1 '-0" NORTH MANN & MANN A R C H I T E C T S / N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.912.7995 KEYNOTES 31. FLOOR LEVELING AS REQ'D TO ALLOW FINISH FLOORING TO ALIGN FLUSH. 32. 1/4" W. ALUM. TERRAllO TYPE DIVIDER STRIP. "SCHLUTER-DECO" (HT. AS REQ'D FOR FLOORING) BY SCHLUTER SYSTEMS. 800.472.4588 75. ALUM. TRANSITION STRIP, "SCHLUTER-RENO-AEU" (HT. AS REQ'D FOR FLOORING) BY SCHLUTER SYSTEMS. FINISHES B-1 BLACK COVE BASE, 4" HIGH B-2 BLACK COVE BASE, 6" HIGH B-4 MAPLE BASE, 2" HIGH CPT -9 DARK GREY CARPET TILE CT -1 LANDLORD TILE CT -3 WHITE TILE CT -4 GRAY TILE R-1 BLACK MATRIX RUBBER R-2 GRAY MATRIX RUBBER R-3 BLUE MATRIX RUBBER R-4 BLUE/GRAY MATRIX RUBBER VCT -1 GRAY VINYL COMPOSITION TILE WF -1 MAPLE WOOD STRIP FLOORING FLOOR LEVELING NOTES: FLOAT TRANSITIONS BETWEEN ALL FLOOR FINISH MATERIALS TO ALIGN FLUSH. FEATHER THE CEMENTMOUS UNDERLAYMENT EVENLY W/ 1/16" VERTICAL CHANGE PER V-0" HORIZONTAL RUN MAXIMUM. REFER ALSO TO WRITTEN SPECIFICATIONS. ALL FLOOR FINISHES SHALL ALIGN FLUSH, UNLESS NOTED OTHERWISE. THERE SHALL BE NO FLOOR SURFACE CHANGE IN HEIGHT (INCLUDING THRESHOLDS) GREATER THAN 1/4". rJUL a' AR19'4C 7 srArF of All drawings, specifications, and designs O Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR Finis � ane CLAY TERRACE CARMEL, 1N SPACE #B 16 FINISH FLOOR PLAN M&MA #4084 FINL STORE #708 A2.2 9 I HOOP SECTION SUSPENDED FROM UNISTRUT SUPPORTS THAT SPAN BETWEEN (E) BEAMS. 3/16" S.S. CABLE. DBL. CABLE CLAMP @ H.D. 6" GALV. STL. TURNBUCKLE TO 3/8" DIAM. STUD WELDED TO HOOP ABOVE EACH NET RING. FASTEN SOLID TO SUPPORT HOOP. STL. PIPE 'HOOP' 3/8" STL. ROD BENT TO DUPLICATE A B -BALL HOOP NET RING (2-1/2" D) WELD SOLID TO HOOP TYP. FOR (12) INSTALL NET FABRICATED BY OTHERS F.F. SCALE: 114 = 1 '-0" 3'-711 9" HIGH x 1 " THK. L u PIN MOUNT—>Uh�l� 11-0" A.F.F. 1/2" OFF G.B. B/SIGN TYP. 5'-2" 12" HIGH x 1 " THK. 1J1J LJ 15 PIN MOUNT 11-0" A.F.F. 3" OFF G.B. B/SIGN TYP. 2'-8 3/4" 12" HIGH x 1 "THK. PIN MOUNT TA � � 11-0" A.F.F. 3" OFF G.B. B/SIGN TYP. WALL MOUNT: 7K 12" HIGH x 1 "THK. 24 O(» PIN MOUNT Q w 11-0" A.F.F. 3" OFF G.B.B/SIGN TYP. BULKHEAD MOUNT: 41-311 12" HIGH x 1 "THICK 24 11— 7 EDGE OF G.B. PIN 1/2" OFFMOUNT G.B. BULKHEAD PER PLANS BOTTOM OF G.B. BULKHEAD PER PLANS WALL SIGNS 3/8" STL. ROD BENT _ TO DUPLICATE A B -BALL HOOP NET RING (2-1/2" D) WELD TO HOOP oa 3 NOTE: GRIND SMOOTH ALL WELDS 9 10' DIAMETER A3.1 /'HOOP' D SCHED.#40 ROLLED STL. PIPE FABRICATE IN TWO PCS. WELD SOLID, GRIND SMOOTH PT. HOOP & HOOKS BRIGHT ORANGE, HIGH -GLOSS ENAMEL, TYP. $ ( HOOP PIAN SCALE: 114 If It 0" 6 MEN WOMEN YOUTH FITTING ROOM PROVIDE LAYOUT J TEMPLATES FOR / / / INSTALLATION. SCALE: 1/4" = 1'-0" ALL LIGHTING TO B` SUSPENDED FROM UNISTRU SUPPORTS THAT SPAP BETWEEN (E) BEAM: SUSPENDEE FLUORESCENT LIGHTING SUSPENDEC TRACK LIGHTING CONTINUOUS TRACK SHOE PANEL SYSTEM. REF. A6.1 FOR COMPONENTS AIM THE TRACKHEAD LIGHTING TO ILLUMINATE THE SHOE PANEL DISPLAYS. SHOE PANEL LIGHTING 4 I ADJUSTMENT DIAGRAM -011 A.F.F. 131 BFLUORESCENT FIXTURES, TYP. 12'-0" A.F.F. B/LAMP (TRACK HEAD) @ PERIMETER OF SALES AREA, TYP. ALL LIGHTING TO BE SUSPENDED FROM UNISTRUT SUPPORTS THAT SPAN — --' BETWEEN (E) BEAMS. SUSPENDED FLUORESCENT LIGHTING. SUSPENDED TRACK LIGHTING CONTINUOUS TRACK FACE OF G.B. PARTITION PER PLAN POST SYSTEM. REF. A6.1 FOR COMPONENTS AIM THE TRACKHEAD LIGHTING TO ILLUMINATE THE POST DISPLAYS. POST DISPLAY LIGHTING 3 1 ADJUSTMENT SCALE: 1/4" = I'-0" 13'-0" A.F.F. --�� B/FLUORESCENT FIXTURES, TYP. 12'-0" A.F.F. B/LAMP (TRACK HEAD) @ PERIMETER OF SALES AREA, TYP. DIAGRAM ATTACHED TO RIGID X SYSTEM, BY USG. 30 HOLD BACK MIN. 1'-0" FROM EDGE TYP. SPLAY BRACE @ 450 ANGLE AS REQ'D FOR ADD'L LATERAL BRACING OR PER CODE. 1'-0" J -BEAD TYP. - - - � TYP. RIGID X CROSS CHANNEL RIGID X MAIN TEE 71 SECTION DETAIL SCALE: 1 1'-0" (E) STRUCTURE NOTE: PAINT ALL EXPOSED FRAMING, HANGERS, SUPPORTS, PT -1, BLACK. 8 GA. WIRE SPLAY BRACING @ 4'-0" o.c., TYP. RIGID X DRYWALL CEILING SUSPENSION SYSTEM BY USG. ENTIRE SYSTEM SHALL BE INSTALLED PER MANUF. SPECIFICATIONS. PT -3 3 10 � SECTION DETAIL SCALE: 3/4" = 1'-0" 12'-4" A.F.F. �_3 B/G.B. CLG. I 5 ELEVATION DETAIL 23'-4" 20 SCALE: 1/4" = 1'-0" 12' 4" A.F.F. PT -3 B/G. B. CLG. r -6 R 5'111t 5 1 1 2 I CEILING LAYOUT DETAILNORTH SCALE: 1/4" = I'-0" 21-011 INSTALL STEEL ANGLE LINTEL HEADER AND METAL CORNER GUARDS AT THE JAMBS OF SERVICE DOOR. LANDLORD TO PROVIDE (EXISTING) SERVICE/EXIT DOOR AT TENANT'S EXPENSE. FINISH PER LANDLORD'S CRITERIA. STOCKROOM SUSPENDED FLUORESCENT LIGHTING, TYP. REFER TO ELECTRICAL PLANS OFFICE STOCKROOM EMERGENCY LIGHTING, TYP. REFER TO ELECTRICAL PLANS. NOTE: PROVIDE BRUSHED CHROME PT 4 8' 0" A.F.F. SPRINKLER HEADS IN THIS CLG. G.B. CLG. PT 1 8'-0" A.F.F. G.B. CLG. LMEN -' 'MEN' 6 .l I (i, AIM AT' MEN1 SIGN w \� STOCKROOM A SUSPENDED FLUORESCENT LIGHTING REFER TO ELECTRICAL PLANS 7-0" O.C. @ APPAREL, TYP. ADJACENT TENANT w SUSPENDED TRACK LIGHTING REFER TO ELECTRICAL PLANS — — — — PT 1 8' 0" A.F.F. G.B. CLG. z N w m MEN LANDLORD TO PROVIDE (EXISTING) SERVICE/EXIT DOOR AND NICHE AT TENANT'S EXPENSE. REFER TO MALL 1.0" A.F.F. CRITERIA MANUAL FOR LANDLORD SCOPE OF WORK. g' -CEILING CONTRACTOR TO COORDINATE ANY ADDITIONAL WORK AT NICHE/ CEILING WITH LANDLORD. B9 MALL EXTERIOR j EXIT /SERVICE ENTRY 8'6" A.F.F. PT 2 G B. CLG. ( m ------ WWI ----- — — I A2.1 j n �'Itll��fl(1 �fl / 63 EQ. EQ. o - o M d o n �� — 1 - 1 / F F\ 1 � -I 1'-o/ -- -I- -- -- -- O — 1 V H N �F 'I F1 H 41-6n H V I 11-311 w I IH - H 1 M " ' N 6' 0 6'-0" w H ISL GRAPHIC c� ! PANEL H 2 'YOUTH' 6 -7 5111 A3.1 3.1 o -2" H E0 l — — — — — — — — — H — — — — -� EXIT CORRIDOR CORRIDOR EMERGENCY - LIGHTING, TYP. REFER TO ELECTRICAL PLANS. -- - BA NOTE: PROVIDE TOILET CHROME SPRINKLDE; HEADS IN THIS CLG. 8'-6" A.F.F. PT -4 G.B. CLG. STOCKROOM EMERGENCY — LIGHTING, TYP. REFER TO ELECTRICAL PLANS. OPEN/EXPOSED CEILING - PT -1 PAINT THE ENTIRE EXPOSE CEILING OF THE VESTIBULE DRESSING ROOM 'FITTING ROOM' A3.1 8'-0" A.F.F. PT -1 G.B. HEADER -- BB AIMAT'FITTING ROOM' SIGN YOUTH 'YOUTH' A3.1 11' 8" TO 10' 8" A.F.F. B/G.B. BULKHEAD. PT 5 REFER TO # 3/A4.1- BLKHD. SLOPES FROM 11'-8" (BACK OF STORE) TO 10'-8" (FRONT OF STORE). ALIGN CASH WRAP CEILING WITH CENTERLINE OF GRAPHIC PANELS BELOW. ADJACENT TENANT AIM AT ''YOUTH' SIGN -- BC STOCKROOM EMERGENCY LIGHTING, TYP. REFER TO ELECTRICAL PLANS. Lid 8'0"AFF 2'-2" O.C. @ SHOE PANELS, TYP. OPEN / EXPOSED CEILING- r" �— " 11 -311 - I311OPEN 41-6 " I j "1' 3" u G.B. CLG. PT 1 STOCKROOM B I ------ — — c --- j j PAINT THE ENTIRE EXPOSED CEILING OF THE SALES AREA INCLUDING THE DECK PT 1 STRUCTURE, PIPING, DUCTWORK, HANGERS, SUPPORTS, CONDUITS, ETC. MEN' 6 1 w H 41.611 l w I ; WOMEN r6 A3 1 WOMEN' I (j �� H" H r " II EQ. I EQ. H I H� I 1 iHH L AIM AT 'MEN' SIGN w H` 1-61 'O 611 H I AIM AT 'WOMEN' SIGN --------------- —'�--- I H w — — I — — — ----- --- ! I BD �- —---------- - -&x-fix------------------------ � - i I I I ---------------------------------------------� LEASE LINE I 5.1 SHOW WINDOW 'A' ENTRY SHOW WINDOW 'B' EXTERIOR SIDE WALK REFLECTED CEILING PLAN NORTH MANN & MANN A R C H I T E C T S / N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.912.7995 KEYNOTES 3. 5/8" TYPE 'X' G.B., TYP. 4. CORNER BEAD, TYP. 20. 3-5/8" 20 GA. MTL. STUD FRAMING @ 161, O.C. 24. 12" H x 1 " THK WHITE LETTERS IN AVANT GARDE BOLD TYPEFACE, PIN MTD., SEE DETAIL THIS PAGE. 30. 8 GA. SUPPORT WIRE @ 4'-0" O.C. 63. HVAC DIFFUSER - SEE MECH. DWGS. PRIME & PAINT TO MATCH ADJACENT SURFACE. FINISHES PT -1 BLACK PAINT PT -2 WHITE PAINT PT -3 BLUE PAINT PT -4 ZOLATONE PAINT PT -5 RED PAINT LIGHTING LAYOUT NOTES: 1. FOCUS ALL TYPE "H" (PAR 38) TRACK HEADS ALONG THE PERIMETER OF THE SALES AREA TOWARDS THE DISPLAY WALL; FOCUS TRACK HEADS AS DIRECTED IN THE "LIGHTING ADJUSTMENT DIAGRAMS" ON THIS PAGE. 2. INSTALL ALL TRACK LIGHTING WITH THE BOTTOM OF THE LAMP @ 12'-0" U.N.O. DO NOT LOCATE ABOVE ANY OBSTRUCTIONS. TRAPEZE DROP TRACK TO COORDINATE W/ DUCTWORK, ETC. HOLD RELOCATED TRACK TIGHT / AS HIGH AS POSSIBLE IN THESE CONDITIONS. DO NOT INSTALL TRACK BELOW 12'-0" A.F.F. WITHOUT ARCHITECTS REVIEW. 3. SWAY BRACE ALL TRACK LIGHTING AS REQUIRED. 4. ALL TYPE 'C' SUSPENDED FLUORESCENT FIXTURES IN THE SALES AREA SHALL BE SHOP D PAINTED FLAT BLACK (PT -1) ON THE EXTERIOR . NON -REFLECTIVE FACES. INSTALL ALL TYPE C' SUSPENDED FLUORESCENT FIXTURES IN THE SALES AREA WITH THE BOTTOM OF THE FIXTURE @ 13'-0" A.F.F. U.N.O. S. FLUORESCENT STOCKROOM LIGHTING SHALL BE MOUNTED W/BOTTOM OF FIXTURE AT 14'-0" A.F.F., TYP. 'JUL 1 2 200 ' 8 � r'l`g7 - %w. STA OE *D I A� \/ gRCN IT �� a�``1 0 ///IyllllliNl�� All drawings, specifications, and designs C Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR wwwFinis � yne ®�eBl ##�t�.�®m CLAY TERRACE CARMEL, IN SPACE #B 16 REFLECTED CEILING PLAN M&MA #4084 FINL STORE Al1 #708 u I NOTE: SECTION CUT LINES ARE APPROXIMATE. PLAN NORTH SOME ELEMENTS HAVE BEEN OMITTED FOR CLARITY. 1 I INTERIOR ELEVATIONS KEY PLAN fi MAPLE BASE V 10 � VIEWAT VESTIBULE N.TS BLACK MIRROR MIRROR �l N I I I I---1 MAPLE BASE 9 I VIEWAT BACK WEST CORNER N.T.S YYIII1L 8 I VIEWAT WOMEN t N.T.S BLACK CONTROL JOINT - BLACK VESTIBULE CL 7 VIEWAT MEN MAI'LL bAbL L MAHN & MANN A R C H I T E C T S l N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.912.7995 KEYNOTES 19, CONT. 112" BLACK MTL. REVEAL 32. 114" w. ALUM. TERRAllO TYPE DIVIDER STRIP. "SCHLUTER-DECO" (HT. AS REQ'D FOR FLOORING) BY SCHLUTER SYSTEMS 800.472.4588, OR EQ. 35. GALV. STL. CORNER GUARD, 1/8" x 1-112" x 1-112" x 48" @ ALL COLS. & CORNERS. NO SHARP EDGES. 358. GALV. STL. CORNER GUARD, 1/8" x 1-1/2" x 1-1/2" x 96" @ ALL COLS. & CORNERS. NO SHARP EDGES. PAINT TO MATCH ADJ. SURFACE. 87, GRAPHICS SNAP FRAME @ 30 A.F.F. 88. GRAPHICS SNAP FRAME @ 43 1/8" A.F.F. MILLWORK KEYNOTES M38, SELF EDGED P. LAM. WAINSCOT OVER 1/2" SUBSTRATE TO 8'-0" A.F.F., WILSONART #1595-50, BLACK (LEAD TIME FINISH) FIXTURE KEYNOTES EC -1 END CAP P-1. MEN'S SHOE PANEL P-2. MEN'S MODULAR SHOE PANEL P-3. WOMEN/ YOUTH SHOE PANEL P-4. WOMEN'S MODULAR SHOE PANEL P-5. INFANT SHOE PANEL SH -1 SHELF, 24" WIDE WM-24H WALL MIRROR, 24" W, HANGRAIL MOUNT FINISHES B-1 BLACK COVE BASE, 4" HIGH B-4 MAPLE BASE, 2" HIGH CT -3 WHITE TILE CT -6 SOLID BLACK TILE CT -9 TEXTURED GRAY TILE PT -1 BLACK PAINT PT -2 WHITE PAINT PT -3 BLUE PAINT PT -5 RED PAINT FINISH NnTF.q- BULKHEAD UP PT -3 TO B/DECK B8 ±15' 10" A.F.F., V.I.F. PT -3 89 G.B. CLG. TYP. NOTE: PROVIDE BRUSHED CHROME SPRINKLER HEADS IN THIS CLG. ADJACENT TENANT STOCKROOM I MEN F F F I WOMEN r STOCKROOM I I ADJACENT TENANT ALUMINUM BAR GRILL SUN SHADE BOLTED TO CANOPY W/ CLIP ANGLES 36'-6" V.I.F. 2 1 PARTIAL REFLECTED CEILING PLAN AT STOREFRONT SCALE: 114" = 1'-0" ADJACENT TENANT STARTING POINT OF WALL FIXTURE LAYOUT. SEE DETAILS ON A6.1. E B8 6'-1" B-4 i I � i ', � ■phi_ _I�li� +..,.+. LJ [ - 4ENR71/'� �7Typ.�_ —LEASE LINE DOOR #0 RVA [;REIE:RS:TO A2=IFIOORINGION i START POINT OF ENTRANCE START POINT OF CHECKERBOARD DOOR CHECKERBOARD TILE PATTERN, 1 2 TILE PATTERN, 3 6-81'FULL TILE AS FULL TILE AS SHOWN A5.3 A5.3 SHOWN A5.3 SHOW WINDOW 'A' 1 LPARTIAL FLOOR PLAN AT STOREFRONT SCALE: 1/4" = U-0" 1 5.2 SHOW WINDOW 'B' A2 STOCKROOM N W 114 --- BD PLAN NORTH PLAN NORTH ADJACENT TENANT STARTING POINT OF WALL FIXTURE LAYOUT. SEE DETAILS ON A6.1. h.+i+�4a+ii�+i+i�i �+�+��+.'J•+++i+++.+i+.+3i ++a++++i+i i aii+. i a^ :1 PT -2 BELOW WALL RAIL, SEE #5/A4.1 CT_3 6 BASE PLAN NORTH MANN & NI mm A R C H I TE C TS I N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.912.7995 KEYNOTES 11. SUSP, SIGN W/BACKLIT PUSH THRU LETTERS. 57. 1-112 "0 SCHEDULE 40, PTD. BILK. STL. PIPE W/ FITTINGS BY KEE KLAMP. 79. CONTINUOUS SURFACE MTD. ALUM. EXTRUSION FOR HANGING GRAPHICS. PAINT PT -3 TYP. 87. GRAPHICS SNAP FRAME @ 30" A.F.F. MILLWORK KEYNOTES M2. DASH WALL SHOE PANELS, MTD. ON 1-1/2" 0 SCHEDULE 40, STD. BLK. STL. PIPE. FINISHES B-4 MAPLE BASE, 2" H. CPT -9 DARK GRAY CARPET CT -1 LANDLORD TILE CT -3 WHITE TILE CT -4 GRAY TILE CT -6 SOLID BLACK TILE PT -3 BLUE PAINT WF -1 MAPLE WOOD STRIP FLOORING �jUL 12 2004 W1O7 �- All drawings, specifications, and designs O Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR Finimfv-Olihmwww.ffnis0�6g CLAY TERRACE CARMEL, IN SPACE #B 16 STOREFRONT PLANS M&MA #4084 FINL STORE Al #708 1 U± -)-- WOMEN WF -1 P-3 TYP.- CPT P-3TYP.- o be =a Lu > 5 o CLVERT. POST +..,.+. LJ [ - 4ENR71/'� �7Typ.�_ —LEASE LINE DOOR #0 RVA [;REIE:RS:TO A2=IFIOORINGION i START POINT OF ENTRANCE START POINT OF CHECKERBOARD DOOR CHECKERBOARD TILE PATTERN, 1 2 TILE PATTERN, 3 6-81'FULL TILE AS FULL TILE AS SHOWN A5.3 A5.3 SHOWN A5.3 SHOW WINDOW 'A' 1 LPARTIAL FLOOR PLAN AT STOREFRONT SCALE: 1/4" = U-0" 1 5.2 SHOW WINDOW 'B' A2 STOCKROOM N W 114 --- BD PLAN NORTH PLAN NORTH ADJACENT TENANT STARTING POINT OF WALL FIXTURE LAYOUT. SEE DETAILS ON A6.1. h.+i+�4a+ii�+i+i�i �+�+��+.'J•+++i+++.+i+.+3i ++a++++i+i i aii+. i a^ :1 PT -2 BELOW WALL RAIL, SEE #5/A4.1 CT_3 6 BASE PLAN NORTH MANN & NI mm A R C H I TE C TS I N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX: 512.912.7995 KEYNOTES 11. SUSP, SIGN W/BACKLIT PUSH THRU LETTERS. 57. 1-112 "0 SCHEDULE 40, PTD. BILK. STL. PIPE W/ FITTINGS BY KEE KLAMP. 79. CONTINUOUS SURFACE MTD. ALUM. EXTRUSION FOR HANGING GRAPHICS. PAINT PT -3 TYP. 87. GRAPHICS SNAP FRAME @ 30" A.F.F. MILLWORK KEYNOTES M2. DASH WALL SHOE PANELS, MTD. ON 1-1/2" 0 SCHEDULE 40, STD. BLK. STL. PIPE. FINISHES B-4 MAPLE BASE, 2" H. CPT -9 DARK GRAY CARPET CT -1 LANDLORD TILE CT -3 WHITE TILE CT -4 GRAY TILE CT -6 SOLID BLACK TILE PT -3 BLUE PAINT WF -1 MAPLE WOOD STRIP FLOORING �jUL 12 2004 W1O7 �- All drawings, specifications, and designs O Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR Finimfv-Olihmwww.ffnis0�6g CLAY TERRACE CARMEL, IN SPACE #B 16 STOREFRONT PLANS M&MA #4084 FINL STORE Al #708 1 O 71 PLAN DETAIL SCALE: 1-1/2" = 1'-0" 1/2" CEMENTITIOUS BOARD 3 PLAN DETAIL SCALE: 1-1/2" = 1'-0" MASTIC SET TILE. SEE ELEVS. FOR TYPE. QUIRK MITRE W/ GROUT JOINT TYP. 2'-3 3/4" CONT. CAULK JOINT, COLOR TO MATCH ALUM. SYSTEM, TYP. 3 PT 3 ABOVE 9'-2" A.F.F. SEE #3/A4.1 R-13 BATT — INSULATION 20 GA. 6" _ METAL STUD t` l 89 n'P. � 3"3 ALUM. STOREFRONT - CT 6 SURFACE SEE KAWNEER NOTE, APPLIED n'P. I BASE, TYP. CONT. CAULK JOINT, COLOR TO MATCH (E) LANDLORD ALUM. SYSTEM, TYP. O CONSTRUCTION O(E) LANDLORD CONSTRUCTION CT 6 CT 9 CT 3 BELOW 9' 2" g PLAN DETAIL A.F.F. MASTIC SET TILE OVER 1/2" CEMENTITIOUS BOARD TYP. SCALE: 1-1 /2" = 1 '-0" (SEE #3,#5/A4.1) BELOW 9'-2" ABOVE 9'-2" CT 6 CT 9 CT 3 A.F.F., A.F.F. DED SEE #3/A4.1 MASTIC SET TILE OVER 1/2" CEMENTITIOUS BOARD TYP. (SEE #3,#5/A4.1) R-13 BATT R-13 BATT i INSULATION INSULATION 20 GA. 6" 20 GA. 6" METAL STUD METAL STUD I CONT. CAULK JOINT, CONT. CAULK JOINT,--\ COLOR TO MATCH COLOR TO MATCH ALUM. SYSTEM, TYP. ALUM. SYSTEM, TYP. N (89)Typ._j ALUM. STOREFRONT SEE KAWNEER NOTE, TYP. -CONT. CAULK JOINT, COLOR TO MATCH ALUM. SYSTEM, TYP, SHOW WINDOW 'A' NORTH 3 1` I _j_r-CONT. CAULK , JOINT, COLOR TO MATCH (_ ALUM. SYSTEM, TYP. v ($9)Typ. — (�)Typ, 1 89 Typ._7, ALUM. STOREFRONT ALUM. STOREFRONT ALUM. STOREFRONT SEE KAWNEER NOTE, SEE KAWNEER NOTE, SEE KAWNEER NOTE, TYP. TYP. TYP. CONT. CAULK JOINT, CONT. CAULK JOINT,- CONT. CAULK JOINT, COLOR TO MATCH COLOR TO MATCH COLOR TO MATCH ALUM. SYSTEM, TYP. ALUM. SYSTEM, TYP. ALUM. SYSTEM, TYP. O(E) LANDLORD O (E) LANDLORD SHOW WINDOW 'A' CONSTRUCTION CONSTRUCTION O TO REMAIN 6 PLAN DETAIL NORTH SCALE: 1-1/2" = I'-0" HOW WINDOW 'A' NORTH N \ Io -00 "SP KE" TYP. FULL DECAL LEFT OF ENTRY "SPIKE" & OUTLINE OF WHITE LETTERING IS 'FINISH LINE BLUE', PMS -300, TYP. • TYP. FULL DECAL RIGHT OF ENTRY NOTE: 2 WINDOW DECAL DETAIL UAT SE ES IIKE"ONPORTONOF ECOO RY. 3'4 SCALE: 3" = 1 '-0" ALUM. STOREFRONT SEE KAWNEER NOTE, TYP. 89 TYP. CT 3 CT 9 CT 6 BELOW 9'-2" A.F.F. SEE #3/A4.1 MASTIC SET TILE OVER 1/2" z CEMENTITIOUS BOARD TYP. (SEE #3,#5/A4.1) C. Q M R-13 BATT INSULATION 20 GA. 6" METAL STUD 3 CONT. CAULK JOINT, COLOR TO MATCH T�,p ALUM. SYSTEM, TYP. I N \ @)TYP. ALUM. STOREFRONT SEE KAWNEER NOTE, TYP. CONT. CAULK JOINT, - COLOR TO MATCH ALUM. SYSTEM, TYP. SHOW WINDOW 'A' 1 5 I PLAN DETAIL SCALE: 1-1/2" = V-0" 2 1(E) LANDLORD - 1 CONSTRUCTION KAWNEER TRIFAB VG 451 FRAMING SYSTEM: FRONT GLAZE (1 " THICK); CLEAR TEMPERED GLAZING; CLEAR ANODIZED FINISH (CLASS II - STANDARD) OR APPROVED EQUAL. ENTRY DOORS, —J u ry SEE Al. 1 /DOOR SCHEDULE ZINC CONTROL JOINT CENTERED ! ON POST, TYP. TYP. U1 I OF DOORS 20 GA. 6" METAL STUD, TYP. CONT. CAULK JOINT, COLOR TO MATCH PT -3 !JOINT-,:\ ALUM. SYSTEM, TYP. DOOR STOP TYP. CONT. CAULK SEE Al.l /DOOR SCHEDULE COLOR TO MALUM. SYSTEM BRAKE METAL STRIP FLUSH W/ ADJACENT STOREFRONT. FINISH TO v - - - MATCH STOREFRONT BLOCKING 8�TYp. a U16 LEASE LINE ALUM. STOREFRONT SEE KAWNEER NOTE, TYP. 2(E) LANDLORD CONT. CAULK JOINT, C LANDLORD COLOR TO MATCH 2 CONSTRUCTION ALUM. SYSTEM, TYP. CONSTRUCTION SHOW WINDOW 'B' K 41 PLAN DETAIL BASE, SEE KAWNEER - - - _ NOTE, TYP.10 TENANT INFILL TENANT INFILL Typ' 89 COLUMN LANDLORD 2 1 I STOREFRONT ELEVATION SHOW WINDOW'A' �UALE: 1/4" = 1 '-C)" 6 5 5.2 5.2 5.2 M, O.H. TENANT INFILL DECAL, 2 2 TYP. A5.2 SCALE: 1-1/2" = 1'-0" R-13 BATT INSULATION TcE)BELOW WALL RAIL, BETWEEN ZINC CONTROL JOINTS SEE #5/A4.1 CT 6 SURFACE APPLIED BASE, TYP, NORTH O TO REMAIN #O1 TENANT INFILL TENANT INFILL ENTRYI SHOW WINDOW 'B' J J_ U - z F_ z Q z Lu j MANN & MANN A R C H I T E C T S I N C 3801 S CAPITAL OF TEXAS HWY SUITE 330 AUSTIN TX 78704 TEL: 512.912.7994 FAX. 512.912.7995 EYNOTES NEUTRAL PIER LANDLORD'S CONSTRUCTION. 5/8" TYPE 'X' G.B., TYP. TRANSLUCENT GRAPHIC ICON 3-5/8" 20 GA. MTL. STUD FRAMING @ 16" O.C. 1 " CLEAR INSULATED, LAMINATED GLAZING, TYP XTURE KEYNOTES . 2" X 2" METAL POST NISHES -3 WHITE TILE -6 SOLID BLACK TILE -9 TEXTURED GRAY PORCELAIN TILE -3 BLUE PAINT ;Jut 12 2G! \\`tltanutr,tffff�� •� A........ � .,t ST Egt' O _ Ate i 437 s STATE OF G 4�M (� ���ffftfrriltltlll� All drawings, specifications, and designs Cc Mann & Mann Architects, Inc. 2004 06.30.04 PERMIT, L.L. REVIEW, BID DATE ISSUED FOR 0 m Finis ane www.ffnishitne.com CLAY TERRACE CARMEL, IN SPACE #B 16 STOREFRONT ELEVATION & DETAILS M&MA #4084 FINL STORE #708 A5.2 4