ABBREVIATIONS GENERAL NOTES SYMBOLS PROJECT INFORMATION 1 REVIEW OF CONTRACT DOCUMENTS AND FIELD CONDITIONS BY CONTRACTOR THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH A EACH OTHER AND WITH AS—BUILT DRAWINGS PROVIDED BY THE OWNER AND SHALL AT ONCE = REPORT TO THE ARCHITECT ERRORS, INCONSISTENCIES OR OMISSIONS. THE CONTRACTOR SHALL BUILDING ADDRESS: 350 EAST 96TH STREET COLUMN GRID LINE 1 DRAWING NOTE . AND JAN. JANITOR TAKE FIELD MEASUREMENTS AND VERIFY FIELD CONDITIONS. THE CONTRACTOR SHALL SUPERVISE I �� INDIANAPOLIS, IN. & AND DIRECT THE WORK. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR AND HAVE CONTROL L ANGLE JT. JOINT OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR @ AT COORDINATING ALL PORTIONS OF THE WORK. CENTERLINE KIT. KITCHEN 2 INTENT OF CONTRACT DOCUMENTS OFFICE CLOUD WITH OCCUPANCY GROUP: B — BUSINESS Libe 0 DIAMETER THE INTENT OF THE CONTRACT DOCUMENTS IS TO ALLOW FOR THE PERFORMANCE OF THE WORK. 100 ROOM NAME AND NUMBER REVISION DELTA ITM I PERPENDICULAR LAB. LABORATORY EVERY ITEM NECESSARILY REQUIRED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. UNLESS SCOPE OF WORK: APPROX. 8,746 SQ. FT. C CHANNEL LAM. LAMINATE EXPRESSLY STATED, ALL SYSTEMS AND EQUIPMENT SHALL BE COMPLETED AND APPROPRIATELY OPERABLE. FURNISH AND INSTALL ALL SPECIFIED AND APPROPRIATE ITEMS, AND ALL INCIDENTAL, # POUND OR NUMBER LAV. LAVATORY ACCESSORY, AND OTHER ITEMS NOT SPECIFIED BUT REQUIRED FOR A COMPLETE AND FINISHED NUMBER OF FLOORS: 4 E EXISTING LKR. LOCKER ASSEMBLY. DIMENSIONS TO FINISH LT, LIGHT 3 DEFECTIVE WORKA8-1SIM. 4' - 3DETAIL REFERENCE FACE CONTRUCTION TYPE: EXISTING - TYPE 1 TYP. " ACOUS./ACT ACOUSTICAL TILE NO WORK DEFECTIVE IN WORKMANSHIP OR QUALITY OR DEFICIENT IN ANY REQUIREMENTS OF THE INDIANA INSURANCE A.D. AREA DRAIN MAX. MAXIMUM CONTRACT DOCUMENTS WILL BE ACCEPTABLE DESPITE THE ARCHITECT'S FAILURE TO DISCOVER ADJ. ADJUSTABLE M.C. MEDICINE CABINET OR POINT OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION. DEFECTIVE WORK REVEALED DIMENSION TO CENTERLINE 350 EAST 96TH STREET WITHIN THE TIME REQUIRED BY GUARANTEES SHALL BE REPLACED BY WORK CONFORMING WITH A.F.F. ABOVE FINISH FLOOR MECH. MECHANICAL THE INTENT OF THE CONTRACT. NO PAYMENT, EITHER PARTIAL OR FINAL, SHALL BE CONSTRUED 1 DETAIL REFERENCE AGGR. AGGREGATE MEMB. MEMBRANE AS AN ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS. A9-1 WITH ARROW INDIANAPOLIS, I N . AL. ALUMINUM MTL, METAL 4 FIREPROOFING APPROX. APPROXIMATE MFR. MANUFACTURER PATCH AND REPAIR ALL FIREPROOFING DAMAGE INCURRED DURING DEMOLITION AND/OR ALIGN SHEETINDEX ARCH. ARCHITECTURAL MH. MANHOLE FIRST FLOOR CONSTRUCTION. FIREPROOF AS REQUIRED BY CODE ALL NEW PENETRATIONS GENERATED BY THE 1 DETAIL FLAG �T WORK DESCRIBED IN THESE DOCUMENTS. A8-1 ASB. ASBESTOS MIN, MINIMUM 5 AS BUILT DRAWINGS ASPH. ASPHALT MIR. MIRROR DURING THE COURSE OF CONSTRUCTION, ACTUAL LOCATIONS OF CONSTRUCTION ITEMS DENOTED MISC. MISCELLANEOUS IN THE CONSTRUCTION DOCUMENTS SHALL BE INDICATED TO SCALE, IN CONTRASTING INK ON A DATUM POINT BD, BOARD M. 0. MASONRY OPENING THE DRAWINGS FOR ALL RUNS OF MECHANICAL, SPRINKLER, PLUMBING AND ELECTRICAL WORK; 07- INCLUDING SITE UTILITIES AND CONCEALED DEVIATIONS FROM THE DRAWINGS. UPON COMPLETION DB ELEVATION REFERENCEBITUM. BITUMINOUS MTD. MOUNTED <% ff OF THE PROJECT THE ARCHITECT WILL PROVIDE THE CONTRACTOR W/ A REPRODUCIBLE SET OF " ARCHITECTURAL BLDG. BUILDING MUL. MULLION ORIGINAL DOCUMENTS FOR "AS—BUILT" DOCUMENTATION. THIS SET SHALL BE CONSPICUOUSLY `� BLK, BLOCK MARKED "AS—BUILTS" AND DELIVERED TO THE ARCHITECT.�� ' AN-1 GENERAL INFORMATION BLKG. BLOCKING 6 TO S RNTENDED THAT°NH TRACTOR PROVIDE A COMPLETE JOB AND ANY OMISSIONS IN SIBILITY CODE REFERENCES AN-2 GENERAL NOTES ,' A. BM. BEAM N. NEW50 z BOT. BOTTOM N.I.C. NOT IN CONTRACT THESE NOTES OR IN THE OUTLINE OF WORK SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR OF SUCH RESPONSIBILITIES IMPLIED BY SCOPE OF WORK EXCEPT FOR ITEMS AN-3 NOT USED B.T.B. BACK TO BACK NO. or # NUMBER BUILDING CODE DATA,. NOM. NOMINAL SPECIFICALLY NOTED. 7 UNENFORCEABLE WORK AN-4 ADA NOTES CAB. CABINET N.T.S. NOT TO SCALE SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE, FOR WHATEVER REASONS, 5, THE SPACE AROUND DUCTS, PIPES, ELECTRICAL C.B. CATCH BASIN UNENFORCEABLE, SUCH UNENFORCEABILITY SHALL NOT EXTEND TO THE REMAINDER OF THE CONDUITS, CABLE TRAYS, AND ALL OTHER 01A-0.0 DEMOLITION PLAN :+' CEM, CEMENTO.A. OVERALL CONTRACT NOR SHALL IT VOID ANY OTHER PROVISIONS OF THE CONTRACT. BUILDING FLOOR AREA: 47,913 SF ELECTRICAL/MECHANICAL WORK PENETRATING RATEDWAL' RS SHALL XCEED HI CER. CERAMIC PROJECT AREA: APPROX. 8,746 SF /2'L AND SHAWE BE PAOCOKED SOLID WOTH EM NERAL 01 A-1.0 PARTITION PLAN ".I } OBS. OBSCURE 8 LIENS C.I. CAST IRON O.C. ON CENTER THROUGHOUT THE DURATION OF THE PROJECT THE CONTRACTOR SHALL REFRAIN FROM ACTIONS _1#11 WOOL OR AN APPROVED EQUAL MATERIAL AND BE O.D. OUTSIDE DIAMETER (DIM. THAT COULD LEAD TO THE FILING OF CLAIMS OF LIEN BY SUBCONTRACTORS, SUPPLIERS OF 01 A-2.0 POWER/SIGNAL PLAN CLO. CEILING ) MATERIALS, LABOR, SERVICE, EQUIPMENT OR ANY OTHER INDIVIDUAL OR COMPANY SO ENTITLED CLOSED OFF BY CLOSE—FITTING ESCUTCHEONS ON CLO. CLOSET BOTH SIDES OF THE PENETRATION. 01 A-3.0 REFLECTED CEILING PLAN OFF. OFFICE UNDER GOVERNING LAWS AND REGULATIONS UNLESS REASONABLE AND JUSTIFIABLE CAUSE CAN o CLR. CLEAR BE SHOWN. APPROVAL FOR PAYMENT SHALL BE CONTINGENT UPON THE CONTRACTOR'S OCCUPANCY CLASSIFICATION: GROUP B — BUSINESS N o OPNG. OPENING OBTAINING AND FURNISHING TO THE ARCHITECT SIGNED RELEASES FROM SUCH INDIVIDUALS OR CONSTRUCTION TYPE: EXISTING — TYPE 1 N o COL. COLUMNOPP. OPPOSITE COMPANIES. 6. THE CONTRACTOR SHALL REPLACE ALL MISSING 01A-4.0 FINISH PLAN CORRIDOR/EXTERIOR WALLS: EXISTING TO REMAIN L CONC. CONCRETE FIREPROOFING & FIRESTOPPING. THE CONTRACTOR > 9 COORDINATION OF THE WORK DEMISING/TENANT SEPARATION WALLS: NONE SHALL REPLACE ALL FIREPROOFING AFFECTED BY °' a CONSTR. CONSTRUCTION P. PAINT 01 A-8.0 DETAILS a:>, THE CONTRACTOR IS RESPONSIBLE FOR REVIEW AND VERIFICATION OF CONTRACT DOCUMENTS, SPRINKLER COVERAGE: FULL NEW CONSTRUCTION WITH FIREPROOFING TO MATCH 4; CL r CONT. CONTINUOUS PRCST. PRECAST FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT WORK IS BUILDABLE BASE BUILDING STANDARDS, APPROVED EQUAL, OR '� v CORR. CORRIDOR PL. PLATE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING CALCULATED OCCUPANT L Q,6D: AS REQUIRED TO MATCH THE EXISTING. p CTSK. COUNTERSUNK P.LAM. PLASTIC LAMINATE THESE OR OTHER COORDINATION ISSUES, THE CONTRACTOR SHALL SUBMIT THEM, IN WRITING, TO THE ARCHITECT AND IS RESPONSIBLE FOR OBTAINING A WRITTEN CLARIFICATION FROM THE 8,746 SF @ 100 SF PER OCC. = 87 OCCUPANTS CNTR. COUNTER 7. ALL EXIT SIGNS SHALL COMPLY WITH SECTION PLAS. PLASTER ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION, OR RELATED WORK. ACTUAL OCCUPANT LOAD= 136 OCCUPANTS 1003.2.10 OF THE INTERNATIONAL BUILDING CODE j N sJ CTR. CENTER PLYWD. PLYWOOD 2000. 10 WORK SHOULD COMPLY W/ APPLICABLE CODES DBL. DOUBLE PR. PAIR EXECUTE WORK IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, FEDERAL CODES, z ti 1. THIS PROJECT IS TO COMPLY WITH, AND HAS 8. ALL CONSTRUCTION TO BE NON—COMBUSTIBLE. DEPT. DEPARTMENT PT. POINT MANUFACTURER'S RECOMMENDATIONS, TRADE AND REFERENCE STANDARDS INCLUDING BUT NOT BEEN DESIGNED IN ACCORDANCE WITH THE a R *k D.F. DRINKING FOUNTAIN P.T.D. PAPER TOWEL DISPENSER LIMITED TO: UBC, SEISMIC CODES, NEC, NEPA, ASMC, UMC, LATEST ENFORCED EDITIONS. FOLLOWING GOVERNING AUTHORITIES: 9. ALL WOOD AND WOOD BLOCKING SHALL BE FIRE 5 a 3 DET. DETAIL P.T.D/R COMBINATION PAPER TOWEL RETARDANT AS PER SECTION 2303 OF THE � Y DIMENSIONS A. INTERNATIONAL BUILDING CODE 2000 INTERNATIONAL BUILDING CODE 2000. ar DIA. DIAMETER DISPENSER &RECEPTACLE 11 DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS B. BUILDING OWNER'S REQUIREMENTS p C w x DIM. DIMENSION AND ELEVATIONS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. WRITTEN C. LOCAL ORDINANCES 10. ALL INTERIOR FINISHES SHALL COMPLY WITH DISP, DISPENSER Q.T. QUARRY TILE SPECIFICATIONS SHALL GOVERN OVER ALL. CHAPTER 8 — INTERIOR FINISHES OF THE U p INTERNATIONAL BUILDING CODE 2000 FOR DN. DOWN 12 CLARIFICATIONS 2. NO CHANGE IN OCCUPANCY FLAMMABILITY & SMOKE DEVELOPED RATINGS AND D.O. DOOR OPENING R RELOCATE CLARIFY ALL DISCREPANCIES RELATIVE TO CONSTRUCTION DOCUMENTS, SPECIFICATIONS, AND FIELD CLASSIFICATION OR CONSTRUCTION TYPE. TOXICITY. CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. DR. DOOR RAD. RADIUS 3. EXECUTE ALL WORK IN ACCORDANCE WITH LOCAL L N N V C^ 13 SUBSTITUTIONS AND FEDERAL CODES, MANUFACTURERS 11 -ALL DOORS TO BE 36" WIDE CLEAR, 34" MIN. DWR. DRAWER R.D. ROOF DRAIN Z N o c c THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED, WHERE RECOMMENDATIONS, TRADE AND REFERENCE (U.0.N.) DS. DOWNSPOUT REF. REFERENCE THE TERM "OR EQUAL" IS USED, THE ARCHITECT ALONE SHALL DETERMINE EQUALITY BASED STANDARDS. c 0 �' v b D.S.P. DRY STANDPIPE REFR. REFRIGERATOR UPON INFORMATION SUBMITTED BY THE CONTRACTOR.W 12. ALL AREAS ARE MECHANICALLY VENTILATED. E DWG. DRAWINGS RGTR. REGISTER 4. ALL EXISTING CONDITIONS INDICATED ARE L C7 w o q 14 DRAWING DISTRIBUTION AS FOUND IN THE FIELD SURVEY OF THE 13, THE CONTRACTOR SHALL PROTECT THE PUBLIC AND REINF. REINFORCED a r ° y " ° N THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES PREMISES BY THE ARCHITECT. EXISTING TENANT FROM ALL WORK IN PROGRESS. w o •• °a��' . E EXISTING REQ'D. REQUIRED UNDER THEIR JURISDICTION. CONDITIONS NOT IN COMPLIANCE WITH�— THOSE SHOWN ARE THE RESPONSIBILITY OF EA. EACH RESIL. RESILIENT15 CHANGES IN THE WORK THE BUILDING OWNER. U Z� d b y E.J. EXPANSION JOINT RM. ROOM DO NOT PROCEED WITH ANY WORK REQUIRING ADDITIONAL COMPENSATION BEYOND THE CONTRACT O , AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER. FAILURE TO OBTAIN h v b� . v EL. ELEVATION R.O. ROUGH OPENING P ROJ ECT DIRECTORY e �E U d ' o AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION. HAZARDOUS MATERIALS NOTES d ~ U v 0,0 ELEC. ELECTRICAL RWD. REDWOOD �l -- a ,a = 1z U U 16 EXISTING WORK U Ca o .k v v > ELEV. ELEVATOR R.W.L. RAIN WATER LEADER ALL INSTALLED PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL OPERATE QUIETLY a w EMER. EMERGENCY AND FREE OF VIBRATION. CLIENT: LIBERTY MUTUAL GROUP r w b 17 PUNCHLIST 1. OWNER ACKOWLEDGES THAT INTERIOR ARCHITECTS SHALL HAVE NO RESPONSIBILITY FOR MAIL STOP WAU1240 > a� U o o v "~ v ENCL. ENCLOSURE S. SOUTH L - b '� THE DISCOVERY REMOVAL PRESENCE HANDLING DISPOSAL OF OR EXPOSURE OF 2000 WESTWOOD DRIVE �' Z o Y E.P. ELECTRICAL PANEL S.C. SOLID CORE UPON COMPLETION OF THE WORK BY THE CONTRACTOR THE CONTRACTOR SHALL NOTIFY THE U ' PERSONS TO HAZARDOUS SUBSTANCES MATERIALS, WASTES IN ANY FORM AT THE WAUSAU, WI 54401-7881 > ARCHITECT IN WRITING OF SUCH COMPLETION. THE ARCHITECT SHALL PREPARE A PUNCH—LIST OF w EQ. EQUAL S.C.D. SEAT COVER DISPENSER PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, PCB, OR p EQPT, EQUIPMENT SCHED. SCHEDULE CORRECTIONS, UNSATISFACTORY, NON—COMPLIANT AND/OR INCOMPLETE WORK. FINAL PAYMENT OTHER TOXIC SUBSTANCES. PROJECT MANAGER: KEITH KASTEN �+ E �j o. d y Y WILL BE CONTINGENT UPON THE COMPLETION OF THESE ITEMS UNDER THE TERMS OF THE 2. THE OWNER ACKNOWLEDGES THAT IT ACCEPTS RESPONSIBILITY FOR NOTIFYING THE PHONE: (715) 842-6012 J E.W.C. ELECTRIC H2O COOLER S.D. SOAP DISPENSEROWNER/CONTRACTOR AGREEMENT. APPROPRIATE FEDERAL, STATE AND LOCAL GOVERNING AGENCIES FOR ANY DEMOLITION, EMAIL: Keith.Kasten@LibertyMutual.com U U O v v y (E) EXISTING SECT. SECTION CONSTRUCTION, OR REPAIR WORK. 18 MATERIALS H b .= v A EXIST. EXISTING SH. SHELF ALL MATERIALS SHALL BE NEW, UNUSED, AND OF THE HIGHEST QUALITY IN EVERY RESPECT 3. ANY QUESTIONS THAT ARISE RELATED TO ASBESTOS SHALL BE REFERRED TO THE OWNER u FOR RESOLUTION. INTERIOR ARCHITECTS SHALL NOT BE REQUIRED TO DO ANY WORK NOR ARCHITECT: IA CHICAGO P.C. A UNLESS OTHERWISE NOTED. MANUFACTURED MATERIALS AND EQUIPMENT SHALL BE INSTALLED AS EXPO. EXPOSED SHR. SHOWER RENDER ANY OPINIONS RELATED TO ASBESTOS. 205 WEST WACKER DRIVE, SUITE 1500 z 0 EXP. EXPANSION SHT. SHEET PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS, U,O.N. CHICAGO, IL. 60606 a v w 19 INSURANCE EXT. EXTERIOR SIM. SIMILAR 4. THE OWNER SHALL RETAIN AN INDEPENDENT CONSULTANT WHO IS TRAINED AND THE CONTRACTOR AND SUBCONTRACTORS SHALL PURCHASE AND MAINTAIN CERTIFICATIONS OF S.N.D. SANITARY NAPKIN DISPENSE INSURANCE WITH RESPECT TO WORKERS COMPENSATION, PUBLIC LIABILITY AND PROPERTY DAMAGE EXPERIENCED IN IDENTIFICATION AND SURVEY OF EXISTING SITES PRIOR TO START OF PROJECT MANAGER: KARA YOUNG F.A. FIRE ALARM S.N.R. SANITARY NAPKIN RECEPTACLE FOR THE LIMITS AS REQUIRED BY LAW, IN ADDITION TO THE TERMS OF THE OWNER'S CONTRACT, DEMOLITION CONSTRUCTION. PHONE: .your 553-5143 WHICH EVER IS GREATER THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, 5. ALL CONTRACTORS AND SUBCONTRACTORS SHALL REPORT THE PRESENCE OF ANY EMAIL: k.young@interiorarchitects.com F.B. FLAT BAR SNT. SEALANT AND SUPERVISING ALL SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK. MATERIAL OR ASSEMBLY SUSPECTED TO CONTAIN ASBESTOS UPON DISCOVERY. THE WORK F.D. FLOOR DRAIN SPEC. SPECIFICATION SHALL BE CARRIED OUT PER THE CONSULTANTS' RECOMMENDATIONS. PROJECT DESIGNER: DENISE MAKAR 20 EXISTING TENANTS PHONE: (312) 553-5160 FDN. FOUNDATION SQ. SQUARE COORDINATE ALL WORK WITH BUILDING OWNER SO AS NOT TO DISTURB OR CAUSE DAMAGE TO EMAIL: d.makar@interiorarchitects.com F.E. FIRE EXTINGUISHER S.S. STAINLESS STEEL ANY TENANT IN THE BUILDING. AVOID CONFLICT AND INTERFERENCE WITH NORMAL BUILDING F.E.C. FIRE EXTINGUISHER CAB S.SK. SERVICE SINK OPERATIONS BY COMPLYING WITH THE BUILDING'S REGULATIONS REGARDING SCHEDULING AND USE OF ELEVATORS AND LOADING DOCKS FOR DELIVERIES, HANDLING OF-MATERIALS, EQUIPMENT, AND F.H.C. FIRE HOSE CABINET STA. STATION DEBRIS. GENERAL CONTRACTOR` DUKE CONSTRUCTION FIN. FINISH STD. STANDARD 600 EAST 96th STREET, SUITE 100 2 ISSUE FOR PERMIT 06/14/04 21 COORDINATION INDIANPOLIS, IN 46240 1 ISSUE FOR PRICING 06/11/04 FL. FLOOR STL. STEEL VERIFY IN THE FIELD, THAT NO CONFLICTS EXIST WHICH WOULD PROHIBIT THE LOCATION OF ANY FLASH. FLASHING STOR. STORAGE AND ALL MECHANICAL, TELEPHONE, ELECTRICAL, LIGHTING, PLUMBING AND SPRINKLER EQUIPMENT GENERAL CONTRACTOR: RICH PRESTHOLT (TO INCLUDE ALL REQUIRED PIPING, DUCTWORK AND CONDUIT) AND THAT ALL REQUIRED PHONE: (317) 808-6191 Issue Description FLUOR. FLUORESCENT STRL. STRUCTURAL Date F.O.C. FACE OF CONCRETE SUSP. SUSPENDED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ABOVE EQUIPMENT ARE PROVIDED. EMAIL: Rich.Prtstholt@dukerealty.com F.O.F. FACE OF FINISH SYM. SYMMETRICAL 22 PROTECTION OF EXISTING WORK PROVIDE PROTECTION TO ALL EXISTING FINISHES IN ALL SPACES WITHIN OR ADJACENT TO THE F.O.S. FACE OF STUDS SCOPE OF WORK AND THE TENANT'S SPACE. THE CONTRACTOR SHALL PATCH REFINISH TO AND FPRF. FIREPROOF TRD. TREAD REPAIR ANY DAMAGE CAUSEDBY HIM OR HIS SUBCONTRACTORS. MATCH EXISTING ADJACENT F.S. FULL SIZE T.B. TOWEL BAR FINISH, OR AS NOTED HEREIN. KEY PLAN SITE PLAN FT. FOOT OR FEET T.C. TOP OF CURB 23 EXISTING DEFECTS F. T. FIRE TREATED TEL. TELEPHONE CORRECT ANY DEFECTS FOUND IN EXISTING BUILDING CONSTRUCTION WHICH AFFECT THE SCOPE OF WORK. THIS INCLUDES BUT IS NOT LIMITED TO UNEVEN SURFACES AND FINISHES AT GYPSUM FTG. FOOTING TER. TERRAllO BOARD OR DAMAGED FIREPROOFING. PATCH AND REPAIR SURFACES TO MATCH ADJACENT, FURR. FURRING T,&G. TONGUE AND GROOVE ADJOINING SURFACES. F&I FURNISH AND INSTALL THK. THICK 24 "TYPICAL" OR "TYP." MEANS IDENTICAL FOR ALL SIMILAR CONDITIONS U.O.N. C H C A G O FUT. FUTURE T.P. TOP OF PAVEMENT 25 "SIMILAR" OR "SIM." MEANS COMPARABLE CHARACTERISTICS TO THE CONDITION NOTED. VERIFY €--_•., `€Ys.>=, IN DIMENSIONS AND ORIENTATION ON PLAN. �.k.apPol T.P.D. TOILET PAPER DISPENSER ry =: 4" " »rtet..:s< k Rf nts>3j`<`Y<ZQ L GA. GAUGE T.V. TELEVISION 26 "VERIFY OR VER." MEANS TO ASCERTAIN AND CONFIRM APPLICATION WITH ARCHITECT. GALV. GALVANIZED T.W. TOP OF WALL m 3`:- Hbme Place 27 FURNITURE aRs; G.B. GRAB BAR TYP, TYPICAL 3 E 164khk FURNITURE SHOWN IS FOR REFERENCE ONLY AND INSTALLED BY OTHERS, U.O.N. C. C. GENERAL CONTRACTOR u 9 = 205 WEST WACKER, SUITE 1500 .W 28 SSE E 9th S#,, �. 28 FILE CABINETS, AS SHOWN ON DRAWINGS, ARE SUPPLIED BY OTHERS. COORDINATE FILE SIZE(S) - ">r. r " CHICAGO ILLINOIS 60606 GL. GLASS/GLAZING UNF. UNFINISHED ¢ Ind' inapali , W/ FURNITURE INSTALLER FOR REQ'D CLEARANCES. �. v� GND. GROUND U.O.N. UNLESS OTHERWISE NOTED s IN� 312 ° 553 ° 8200 FAX 312 -553-8208 29 CLEANING _� j I� GR. GRADE UR. URINAL PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS FROM MIGRATING GYP. GYPSUM FROM CONSTRUCTION AREA. x " `� `� '""a'. 0 2003 IA CHICAGO, P.C. V.C.T. VINYL COMPOSITION TILE ALL DRAWINGS AND WRITTEN MATERIAL, HEREIN, CONSTITUTE THE ORIGINAL 30 ADJACENT SPACES s s AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME MAY NOT BE H.BHOME BID VERT. VERTICALL CONTRACTOR SHALL BE FOR SCHEDULINGDULING 0F ACCESS SS INTO ADJACENT TENANT �=.•F�,"'"�.3 .� :_� �# �., �:> `: �. ' ,'» %: � •, DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ��. �``�'°*'�,� ;,:t s � � ARCHITECT. OF SPACES WITH THE BUILDING MANAGEMENT AS REQUIRED FOR PRICING AND EXECUTION OF THE ■ f "mss ;,< k„ H. C. HOLLOW CAB VEST. VESTIBULES WORK. W, HDWD. HARDWOOD V.I.F. VERIFY IN FIELD 31 EXISTING CONDITIONS m ' HDWE. HARDWARE CONTRACTOR SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS, NOTWITHSTANDING ANY INFORMATION SHOWN OR NOT INDICATED ON THE s I H.M. HOLLOW METAL W. WEST CONTRACT DOCUMENTS. m m €{ g 31Yf q f H OR I Z. HORIZONTAL W/ WITH i F Drawn: DM Check: KSY Owner Approval 32 CONTRACT DOCUMENTS HR. HOUR W.C. WATER CLOSET. ALL CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS CALLED FOR BY ANY WILL BE AS p p ® p 2004: rosoRca o ecli an4°� h� HGT. HEIGHT WD. WOOD BINDING AS IF CALLED FOR BY ALL. ALL WORK SHOWN OR REFERRED TO ON ANY CONTRACT ® ® Job No: 54132.00 Scde: AS NOTED k W/0 WITHOUT DOCUMENT SHALL BE PROVIDED AS THOUGH THEY ARE ON ALL RELATED DOCUMENTS. OLD 1. D. INSIDE DIAMETER (DIM.) WP. WATERPROOF 33 CONTRACTOR RESPONSIBILITY TO NOTIFY ARCHITECTlsbIT SHALL ® ® • CT OF ANY INSUL. INSULATION WSCT. WAINSCOT CONFLIICTSHERE HE THE EREIN (APPARENT OR OBVIOUS TY OF THE R—TP ORI 0 THE SFY THE TART EOF NEW WORK ON COVSTR' CmON INT. INTERIOR WT. WEIGHTTHAT ITEM OR BEAR THE RESPONSIBILITY OF CORRECTING SUCH WORK AS DIRECTED BY THE wee, -=ate AREA OF WORK ARCHITECT. of Stag and Loa( Codes, 34 DUPLICATION OF DOCUMENTS DEPT OF COMMUNITY SERVICES GENERAL ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED OF C�p� /CLAY "�t31dW.h,NI�; DIORK SCLOOSEDTHE WITHOUTITHETWRITTEN CONSENT OF NER AND THE ME MAY NOT BE THE ARCHITECT/OWNERATED, USED, OR Title: INFORMATION 35 EXISTING PENETRATIONS 0 ALL PENETRATIONS TO THE FLOOR/CEILING ASSEMBLY SHALL BE GROUTED SOLID WITH .A o QUICK—SET CONC. FILLER. THE SLAB BETWEEN THE MECH. EQPT. ROOM AND THE TENANT SPACE ° SHALL BE ACOUSTICALLY SEALED AIRTIGHT WITH FIRE SEAL PER APPLICABLE CODE. Sheet: ANo 0 o - DEMOLITION NOTES 1. SUMMARY WORK NECESSARY FOR COMPLETE DEMOLITION INCLUDES FURNISHING LABOR FOR DEMOLITION, REMOVAL OF DEBRIS, PATCHING AS REQUIRED, CONTROL DUST, AND NECESSARY PERMITS. 2. TYPES OF SELECTIVE DEMOLITION WORK DEMOLITION WILL REQUIRE THE SELECTIVE REMOVAL AND SUBSEQUENT OFF SITE DISPOSAL OF THE FOLLOWING: REMOVAL OF ALL CARPET AND PAD WHERE OCCURS 3. SCHEDULE SUBMIT SCHEDULE INDICATING PROPOSED SEQUENCE OF OPERATIONS FOR SELECTIVE DEMOLITION WORK TO ARCHITECT AND THEIR CONSULTANTS, AND THE OWNER'S REPRESENTATIVE CITY BUILDING OFFICIALS, AND BUILDING MANAGEMENT FOR REVIEW. INCLUDE COORDINATION FOR SHUT OFF, CAPPING, AND CONTINUATION OF UTILITY SERVICES AS REQUIRED. TOGETHER WITH DETAILS FOR DUST AND NOISE CONTROL. PROVIDE DETAILED SEQUENCE OF DEMOLITION, FLOOR BY FLOOR, AND REMOVAL WORK TO ENSURE UNINTERRUPTED PROGRESS OF OWNER'S ON-SITE OPERATIONS, AND BUILDING OPERATIONS. 4. CONDITION OF STRUCTURES OWNER ASSUMES NO RESPONSIBILITY FOR ACTUAL CONDITION OF ITEMS OR STRUCTURES TO BE DEMOLISHED. IF ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE DISCOVERED DURING CONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE OWNER IN WRITING, THEN WAIT FOR DIRECTION FROM THE OWNER. OWNER'S CONSULTANT HAS PREVIOUSLY CONDUCTED A PHASE 1 ENVIRONMENTAL ASSESSMENT WHICH INDICATES THE PRESENCE OF ASBESTOS CONTAINING BUILDING MATERIALS (ACBM). THERE MAY BE OTHER AREAS WHICH CONTAIN ACBM. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS FOR REMOVAL, HANDLING, PROPER DISPOSAL OF, OR EXPOSURE OF PERSONS TO THE HAllARDOUS SUBSTANCES. OTHER MATERIALS AND WASTE IN ANY FORM AT THE PROJECT SITE MAY BE LOCATED ON THE PROJECT SITE, WHICH MAY INCLUDE, BUT NOT BE LIMITED TO ACBM, PCB'S OR OTHER TOXIC SUBSTANCES. CONDITIONS EXISTING AT THE TIME OF COMMENCEMENT OF CONTRACT WILL BE MAINTAINED BY OWNER INSOFAR AS PRACTICAL. HOWEVER, VARIATIONS WITHIN STRUCTURE MAY OCCUR BY OWNER'S REMOVAL AND SALVAGE OPERATIONS PRIOR TO START OF SELECTIVE DEMOLITION WORK. 5. PARTIAL DEMOLITION AND REMOVAL STORAGE OF REMOVED ITEMS WILL BE PERMITTED AS DIRECTED BY THE OWNER. 6. PROTECTIONS PROVIDE PROTECTIVE BARRICADES, PROTECTIVE CANOPIES, AND OTHER FORMS OF PROTECTION AS REQUIRED TO PROTECT OWNER'S PERSONNEL AND GENERAL PUBLIC FROM INJURY DUE TO SELECTIVE DEMOLITION WORK. PROVIDE PROTECTIVE MEASURES AS REQUIRED TO PROVIDE FREE AND SAFE PASSAGE OF OWNER'S PERSONNEL, TENANT, THEIR EMPLOYEES, AND THEIR INVITEES AND GENERAL PUBLIC TO AND FROM OCCUPIED PORTIONS OF BUILDING. PROTECT FROM DAMAGE EXISTING FINISH WORK THAT IS TO REMAIN IN PLACE AND BECOMES EXPOSED DURING DEMOLITION OPERATIONS. PROTECT FLOORS WITH SUITABLE COVERINGS WHEN NECESSARY. CONSTRUCT TEMPORARY INSULATED SOLID DUST PROOF PARTITIONS WHERE REQUIRED TO SEPARATE AREAS WHERE NOISY OR EXTENSIVE DIRT OR DUST OPERATIONS ARE PERFORMED. EQUIP PARTITIONS WITH DUST PROOF DOORS AND SECURITY LOCKS IF REQUIRED PROVIDE TEMPORARY WEATHER PROTECTION DURING INTERVAL BETWEEN DEMOLITION AND REMOVAL OF EXISTING CONSTRUCTION ON EXTERIOR SURFACES, AND INSTALLATION OF NEW CONSTRUCTION TO ENSURE THAT NO WATER LEAKAGE OR DAMAGE OCCURS TO STRUCTURE OR INTERIOR AREAS OF EXISTING BUILDING. REMOVE PROTECTIONS AT COMPLETION OF WORK. 7, DAMAGES PROMPTLY REPAIR DAMAGES CAUSED TO ADJACENT FACILITIES BY DEMOLITION WORK AT NO ADDITIONAL COST TO OWNER. 8. TRAFFIC CONDUCT SELECTIVE DEMOLITION OPERATIONS AND DEBRIS REMOVAL IN A MANNER TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHER ADJACENT OCCUPIED OR USED FACILITIES. 9. UTILITY SERVICES MAINTAIN EXISTING UTILITIES TO REMAIN, KEEP IN SERVICE, IDENTITY, AND PROTECT AGAINST DAMAGE DURING DEMOLITION OPERATIONS. PROVIDE TEMPORARY LIGHT AND POWER AS REQUIRED. SEE DRAWINGS FOR EXISTING STANDPIPE LOCATIONS. REMOVAL OF ANY EQUIPMENT, CABELING SWITCHES, AND CONDUIT PERTAINING TO DATA/ COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES SERVICE OWNER OR TENANT DATA/COMMUNICATIONS REPRESENTATIVE AS REQUIRED TO PREVENT NEW CONSTRUCTION DELAYS. REMOVE TO SOURCE ALL PIPES, VENTS, APPLIANCES OR DRAINS NOT BEING RE -USED. 10. ENVIRONMENTAL CONTROLS USE TEMPORARY ENCLOSURES, AND OTHER SUITABLE METHODS TO ISOLATE DUST, DIRT RISING AND SCATTERING. COMPLY WITH BUILDING MANAGEMENT REGULATIONS AND GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION. 11. INSPECTION PRIOR TO COMMENCEMENT OF SELECTIVE DEMOLITION WORK, INSPECT AREAS IN WHICH WORK WILL BE PERFORMED IF NECESSARY. PHOTOGRAPH EXISTING CONDITIONS TO STRUCTURE SURFACES, EQUIPMENT OR TO SURROUNDING PROPERTIES WHICH COULD BE MISCONSTRUCTED AS DAMAGE RESULTING FROM DEMOLITION WORK; FILE WITH OWNER PRIOR TO STARTING WORK. 12. PREPARATION CONTRACTOR IS SOLELY RESPONSIBLE FOR ANY INTERIOR AND EXTERIOR SHORING, BRACING, OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURES TO BE DEMOLISHED AND ADJACENT FACILITIES TO REMAIN. WORK SHALL BE DONE UNDER THE SUPERVISION OF A LICENSED STRUCTURAL ENGINEER. PROVIDED BY THE CONTRACTOR AT THE PROJECT SITE. CONTRACTOR SHALL CEASE OPERATIONS AT HIS/HER DISCRETION AND NOTIFY OWNER AND BUILDING MANAGEMENT IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AS DIRECTED BY THE CONTRACTORS LICENSED STRUCTURAL ENGINEER TO SAFELY SUPPORT THE STRUCTURE UNTIL A DETERMINATION IS MADE FOR CONTINUING THE WORK AS DIRECTED BY THE CONTRACTOR'S LICENSED STRUCTURAL ENGINEER. TAKE PRECAUTIONS TO SUPPORT STRUCTURE UNTIL DETERMINATION IS MAKE FOR CONTINUING OPERATIONS, CONTRACTOR IS SOLELY RESPONSIBLE FOR DEMOLITION MEANS AND METHODS. 13. COVER AND PROTECT COVER AND PROTECT FURNITURE, EQUIPMENT AND FIXTURES AND OTHER ITEMS TO REMAIN FROM SOILING OR DAMAGE WHEN DEMOLITION WORK IS PERFORMED IN ROOMS OR AREAS FROM WHICH SUCH ITEMS HAVE BEEN REMOVED. 14, CLEAN UP AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREAS SHALL BE LEFT IN BROOMED AND CLEAN CONDITION. CARPETED AREAS TO BE LEFT IN A VACUUM CLEAN CONDITION. VINYL FLOORING SHALL BE DAMP MOPPED AT THE END OF EACH WORK DAY. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED AT THE END OF EACH WORK DAY. 15. FREIGHT ELEVATOR DEBRIS REMOVAL MUST BE PERFORMED USING THE FREIGHT ELEVATOR. CONTACT THE BUILDING MGMT. OFFICE TO OBTAIN SCHEDULE FOR THE USE OF THE FREIGHT ELEVATOR PRIOR TO SUBMITTING BID. ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT REQUIREMENTS AND PROCEDURES. 16. EXISTING ELECTRICAL IN PARTITIONS TO BE REMOVED, REMOVE AND CAP ALL OUTLETS, SWITCHES, WIRES, THERMOSTATS, ETC.. TO THEIR SOURCE AS REQUIRED. ALL EXISTING FLOOR MOUNTED OUTLETS, WHERE NOTED TO BE REMOVED OR RELOCATED SHALL BE CAPPED OFF TO THE NEAREST JUNCTION BOX. FILL AND LEVEL FLOOR TO ACCEPT NEW FLOOR COVERING. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO DATA/ COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES, SERVICE OWNER OR TENANT DATA/COMMUNICATIONS REPRESENTATIVE AS REQUIRED TO PREVENT NEW CONSTRUCTION DELAYS. 17. PATCHING CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND/OR REPAIRING ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS TO EXISTING CONSTRUCTION IN ELEVATOR LOBBY, PUBLIC CORRIDORS, RESTROOMS OR TENANT SPACES. REFINISH TO MATCH EXISTING ADJACENT FINISH, OR AS NOTED HEREIN. 18. PIPES, VENTS, ETC. REMOVE TO SOURCE ALL PIPES, VENTS, APPLIANCES OR DRAINS NOT BEING RE -USED. 19. FLOORING REMOVE ALL EXISTING IRREGULAR MATERIALS WHICH CAUSE RISES AND DEPRESSIONS IN FLOORING SURFACE, SUCH AS FASTENERS, OUTLET CORES, COVER PLATES, RESILIENT FLOOR COVERINGS, CARPET, CARPET PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC... 20. WALL COVERING CAREFULLY REMOVE ALL EXISTING WALL COVERING AT EXISTING PARTITIONS AND/OR COLUMNS, AS NOTED. 21, DEMOLITION DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DRAWINGS. THE INTENT IS TO INDICATES THE GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPLETE THE WORK IN IF QUESTIONS ARISE AS TO THE REMOVAL OF ACCORDANCE WITH THE CONTRACT DOCUMENTS. ANY MATERIAL, CLARIFY THE POINT IN QUESTION WITH THE ARCHITECT BEFORE PROCEEDING. 22. STAIRWAYS STAIRWAYS MUST REMAIN ACCESSIBLE AT ALL TIMES DURING DEMOLITION. 23. GRAPHICS REMOVE EXISTING SIGNAGE/GRAPHICS AND STORE FOR RE -USE WHERE APPLICABLE. 24. FIRE AND LIFE SAFETY SYSTEM NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS, NO ACTIVE SMOKE DETECTOR SHALL BE COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN ITS INTENDED PURPOSE. FIRE/LIFE SAFETY REQUIREMENTS; 1. GENERAL CONTRACTOR TO ENSURE THAT ALL EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING MORE THAN 50 PERSONS. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT ANY SPECIAL KNOWLEDGE OR EFFORT AND SHALL BE SELF-CLOSING. 2. GENERAL CONTRACTOR TO ENSURE THAT ALL DOORS OPENING INTO ONE-HOUR FIRE - RATED CORRIDORS SHALL RECEIVE SMOKE STOP FIRE ASSEMBLY WITH 20 MINUTE RATING. 3. GENERAL CONTRACTOR TO PROVIDE FIRE DAMPERS OR DOORS WITH ALL REQUIRED LIFE SAFETY CONNECTIONS WHERE AIR DUCTS PENETRATE FIRE -RATED WALLS OR CEILINGS. 4. EXITS, EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS AND FIRE EXTINGUISHERS SHALL NOT BE CONCEALED BY ANY DECORATIVE MATERIALS. 5. GENERAL CONTRACTOR TO MODIFY EXISTING FIRE EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTION. GENERAL CONTRACTOR TO CHECK FIRE ALARM SYSTEM FOR PROPER SOUND COVERAGE THROUGHOUT THE LEASED SPACE. PROVIDE SMOKE DETECTORS THROUGHOUT TENANT AREA IN ACCORDANCE WITH CODES. GENERAL CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS WITH RATING OF NOT LESS THAN 2A OR 2A1OBC WITHIN 75'-0" TRAVEL DISTANCE TO ALL PORTIONS OF THE FLOOR DURING AND AFTER CONSTRUCTION. GENERAL CONTRACTOR TO PROVIDE AN ALLOWANCE IN BID. 6, EXIT SIGNS SHALL BE CLEARLY VISIBLE AT ALL TIMES & SHALL HAVE BLOCK LETTERS 6" HIGH x 3/4" STROKE EXIT SIGN COLOR AND DESIGN OF LETTERING SHALL BE IN HIGH CONTRAST WITH THEIR BACKGROUND. (SECTION 1013.2, 95 CBC). 7. EXIT SIGNS SHALL BE ELECTRONICALLY ILLUMINATED AND ENERGIZED FROM SEPARATE CIRCUITS. SEE ELECTRICAL PLANS. ONE OF THE ABOVE CIRCUITS SHALL BE PART OF THE EMERGENCY LIGHTING SYSTEM. 8. THE END POINT FLAME SPREAD OF 200 AND RATING OF 75 FOR INTERIOR WALL AND CEILING FINISHES AS REQUIRED. RATING OF 25 FOR STAIRWELLS AS REQUIRED. 9. THE G.C. IS TO EXTEND OR MODIFY EXISTING FIRE LIFE SAFETY SYSTEM AS REQ'D. 10. FIRE DEPARTMENT FINAL INSPECTION REQUIRED. 11. STORAGE, DISPENSING, OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE GASES AND HAZARDOUS CHEMICALS SHALL COMPLY WITH UNIFORM FIRE CODE REQUIREMENTS. 12. PROVIDE ILLUMINATED EXIT SIGNS AT REQUIRED EXIT DOORWAYS. (REQUIRED ILLUMINATED EXIT SIGNS WHEN THE EXIT SERVES AN OCCUPANT LOAD OF 50 OR MORE.) REQUIRED BY LOCAL FIRE DEPARTMENT WITH AT LEAST 5.0- FOOT CANDLES, WITH TWO SOURCES OF POWER -ELECTRIC AND BATTERY. SPRINKLER NOTES 1. SEE ENGINEERING DRAWINGS FOR LOCATION OF HEADS, BRANCH PIPING, ETC. AND ALL WORK REQUIRED TO COMPLETE THIS PROJECT. SUBMIT PLANS TO CHIEF BUILDING ENGINEER AND OBTAIN HIS REVIEW PRIOR TO COMMENCEMENT OF ANY SPRINKLER WORK. 2. G.C. SHALL COORDINATE AND ARRANGE FOR DRAINING AND REACTIVATION OF EXISTING SPRINKLER SYSTEMS WITH BUILDING MANAGEMENT, AS REQUIRED. 3, G.C. SHALL BE RESPONSIBLE FOR TEMPORARY FIRE WATCH AND ALL PROTECTIVE MEASURES REQUIRED BY BUILDING MANAGEMENT WHEN SYSTEM IS MADE INACTIVE TO ACCOMMODATE MANAGEMENT SPRINKLER WORK. 4. G.C. SHALL BE RESPONSIBLE FOR ALL FINAL TESTS AND INSPECTIONS OF COMPLETED WORK REQUIRED BY THE BUILDING MANAGEMENT PRIOR TO OCCUPANCY OF SPACE. 5. ALL SPRINKLER WORK SHALL BE TESTED AND MADE OPERATIONAL PRIOR TO CARPET AND FURNITURE INSTALLATION. G.C. SHALL REPAIR AND REPLACE ALL FINISHES DAMAGED BY DEFECTIVE SPRINKLER WORK, AT HIS EXPENSE. 6, G.C. SHALL PROPERLY TEST AND INSPECT EXISTING SPRINKLER SYSTEM PRIOR TO COMMENCEMENT OF WORK, AND SHALL NOTIFY LANDLORD AND IA IMMEDIATELY IF REPAIR WORK OF EXISTING SPRINKLER SYSTEM IS REQUIRED. 7. ALL BURNING, CUTTING, SOLDERING AND WELDING SHALL BE COORDINATED WITH BUILDING MANAGEMENT PRIOR TO COMMENCEMENT OF WORK. 8. G.C. SHALL COORDINATE ARRANGEMENTS FOR TEMPORARY DISCONNECT AND RECONNECT OF FIRE SYSTEMS WITH BUILDING MANAGEMENT. 9. G.C. SHALL BE RESPONSIBLE FOR OBTAINING PERMITS AND APPROVALS REQUIRED BY BUILDING INSPECTORS AND FIRE MARSHALL IN CONJUNCTION WITH CHANGES TO EXISTING SPRINKLER SYSTEM. 10. ALL SPRINKLER HEADS (BUILDING STANDARD TYPE) SHALL BE INSTALLED IN THE CENTER OF CEILING GRID. ANY DEVIATION TO THIS NOTE MUST BE REVIEWED WITH IA PRIOR TO PROCEEDING WITH WORK 11. FIRE SPRINKLER SYSTEM(S) PER N.F.P.A. STANDARD 13 SHALL BE PROVIDED. 12. PLANS FOR FIRE SPRINKLER ALTERATIONS SHALL BE SUBMITTED (THREE COPIES) TO THE BUILDING DEPARTMENT FOR FIRE DEPARTMENT APPROVAL PRIOR TO INSTALLATION. 13. COMPLY WITH CHAPTER 9, 95 CBC FOR AUTOMATIC FIRE SPRINKLER IF EXISTING BUILDING IS AUTOMATICALLY SPRINKLERED AND NEW, ADDITIONAL OR RELOCATED AUTOMATIC FIRE SPRINKLER HEADS FOR NEW WORK AND REMODELED AREAS ARE PROVIDED. MECHANICAL NOTES 1. THE G.C. SHALL PROVIDE ALL HEATING, VENTILATION AND AIR CONDITIONING WORK AS CALLED FOR AND SPECIFIED BY THE CONTRACT ENGINEERING DOCUMENTS AND DRAWINGS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD SUPERVISION OF ALL HVAC WORK DURING INSTALLATION AND SHALL INSPECT ALL SYSTEMS FOR PROPER OPERATION AT COMPLETION OF THE JOB. 3. SHOP DRAWINGS OF DUCTWORK AND REGISTERS INCLUDING ACCESS PANELS IF REQUIRED SHALL BE SUBMITTED TO IA for APPROVAL PRIOR TO PROCEEDING WITH FABRICATION AND/OR INSTALLATION OR RELOCATION. 4. AIR CONDITIONING SYSTEM THROUGHOUT ENTIRE SPACE IS TO BE PROPERLY BALANCED AFTER MOVE IN. AIR BALANCE SHALL BE PERFORMED BY AN INDEPENDENT AIR BALANCE CONTRACTOR WHO SHALL CERTIFY THAT THE REPORT IS ACCURATE. SUBMIT 2 COPIES TO LANDLORD. 5. HVAC CONTRACTOR TO REFER TO REFLECTED CEILING AND FURNITURE DRAWINGS FOR OCCUPANCY FIGURES AND HEAT PRODUCING EQUIPMENT. II 6. INSTALLATION SHALL BE COORDINATED WITH ALL TRADES AS REQUIRED FOR PROPER ASSEMBLY. CEILING DIFFUSERS TO BE RELOCATED TO MAINTAIN NEW FIXTURE PATTERNS IF REQUIRED. 7. INTERIOR SPACES SHALL BE MECHANICALLY VENTILATED IN ACCORDANCE WITH THE ADMINISTRATIVE CODE. PLANS SHOWING MECHANICAL VENTILATION SYSTEM WILL BE FILED IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT OF BUILDINGS. 8. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL POWER AND CONTROL WIRING REQUIRED FOR THE HVAC SYSTEM. 9. ANY BUILDING SHUT DOWNS REQUIRED FOR THIS WORK SHALL BE REQUIRED IN WRITING BY THE CONTRACTOR AT LEAST 72 HOURS IN ADVANCE OF THE SHUT DOWN. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM ALL AUTHORITIES HAVING JURISTICTION PRIOR TO SHUTDOWN. ANY SHUTDOWN AFFECTING THE NORMAL HVAC SERVICE OF OTHER BUILDING OCCUPANTS SHALL BE DONE ON OVERTIME. 10. ALL OUTSIDE LOUVERS SHALL MATCH EXISTING AND SKETCHES SHALL BE SUBMITTED TO BUILDING FOR APPROVAL PRIOR TO INSTALLATION. NO OUTSIDE LOUVER OR DUCTWORK IS TO BE INSTALLED IN SUCH A MANNER AS TO INTERFERE WITH THE CLEANING OF WINDOWS OR REPLACEMENT OF GLASS AND WITHOUT BUILDING APPROVAL. 11. ALL PERIPHERAL SHUT-OFF VALVES SHALL BE ACCESSIBLE AT ALL TIMES. 12. AFTER COMPLETION OF ALL AIR CONDITIONING WORK, THE CONTRACTOR SHALL BALANCE ALL SYSTEMS AND SUBMIT DESIGN BALANCING FIGURES TO THE BUILDING AFTER APPROVAL FROM THE DESIGN ENGINEER. SEE NOTE 4, ABOVE FOR ADDITIONAL REQUIREMENTS. 13, THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL PLUMBING ROUGH -IN, FIXTURES AND ACCESSORIES SHOWN ON ALL PLANS AND DETAIL DRAWINGS. 14. THE CONTRACTOR SHALL SUBMIT CUTS OF ALL FIXTURES, FITTINGS AND ACCESSORIES TO IA FOR APPROVAL. 15. THE CONTRACTOR SHALL COORDINATE HIS PLUMBING WORK WITH MANUFACTURER'S SPECIFICATIONS. 16. ALL RISER SHUTDOWNS SHALL BE SUPERVISED BY BUILDING AS DIRECTED BY BUILDING MANAGEMENT. NO WATER RISERS SHALL BE SHUTDOWN DURING BUILDING OFFICE HOURS. 17. THE CONTRACTOR SHALL PLAN INSTALLATION OF NEW PLUMBING WORK AND CONNECTIONS TO EXISTING WORK TO INSURE MINIMUM INTERFERENCE WITH REGULAR OPERATIONS OF EXISTING FACILITIES. SUBMIT TO THE BUILDING MANAGER A DATE SCHEDULE FOR APPROVAL OF NECESSARY TEMPORARY SHUTDOWNS OF EXISTING SERVICES. ALL SHUTDOWNS SHALL BE MADE AT SUCH TIME AS WILL NOT INTERFERE WITH REGULAR OPERATIONS OF EXISTING FACILITIES AND ONLY AFTER WRITTEN APPROVAL OF THE BUILDING MANAGER. LIGHTING &ELECTRICAL NOTES 1. REFER TO DESIGN/BUILD ENGINEERING DRAWINGS FOR ALL CIRCUITING AND POWER REQUIREMENTS. THE ARCHITECTURAL DRAWINGS ARE FOR LOCATIONS AND DIMENSIONS. 2. G.C. TO FURNISH AND INSTALL ALL LIGHTING, HVAC AND RELATED MECHANICAL WORK IN STRICT COMPLIANCE WITH LOCAL CODES. 3. NIGHT LIGHTS, EXIT LIGHTS AND ALARMS SHALL BE PROVIDED BY G.C. AS REQUIRED BY APPLICABLE CODES. 4. ALL LIGHTING IS TO BE INSTALLED IN CONFORMANCE WITH PERTINENT ELECTRICAL CODES. 5. ALL RECESSED FIXTURES SHALL BE SET FLUSH WITH ACOUSTIC TILE CEILING; AS RECOMMENDED BY MANUFACTURERS. 6. ALL LIGHT FIXTURES MAY BE SUBSTITUTED BY FIXTURE OF EQUAL QUALITY WITH APPROVAL BY IA. 7. NOT USED. 8. G.C. SHALL RECIRCUIT AND REWIRE EXISTING PANEL BOARD (S) AS REQUIRED IN ELECTRIC CLOSET TO ACCOMMODATE IA ELECTRIC POWER AND LIGHTING DESIGN (SEE DESIGN/BUILD ENGINEER DWGS.) 9. PANEL BOARD CIRCUIT BREAKERS SHALL BE NEATLY TAGGED AND NUMBERED BY G.C. TO CORRESPOND WITH CIRCUITING OUTLINED ON DESIGN/BUILD ENGINEERING DRAWINGS. 10. G.C. SHALL PROVIDE ALL NEW PANEL BOARDS AS REQUIRED IN ADDITION TO ANY REQUIRED REWIRING OF EXISTING. SEE DESIGN/BUILD ENGINEERING DRAWINGS. 11. G.C. SHALL PERFORM ALL ELECTRICAL WORK IN ACCORDANCE WITH ANY AND ALL GOVERNING LOCAL CODES, THE NATIONAL ELECTRIC CODE AND BUILDING RULES AND REGULATIONS. 12. C.C. SHALL PROVIDE AND INSTALL ALL ELECTRIC CONTROL WIRING TO PROVIDE A COMPLETE SUPPLEMENTARY AC SYSTEM. SEE DESIGN/BUILD ENGINEERING DRAWINGS. 13. G.C. TO PROVIDE AND INSTALL COVER PLATES FOR ALL WALL MOUNTED ELECTRICAL AND COMMUNICATIONS OUTLETS. 14. G.C. SHALL PROVIDE 115V SEPARATE CIRCUIT AND SURGE PROTECTOR AT COPIER LOCATION. 15. ALL WALL MOUNTED DATA AND VOICE RECEPTACLES TO HAVE 3/4" CONDUIT STUB UP AND TERMINATED 6" ABOVE HUNG CEILING. 16. G.C. SHALL PROVIDE AND INSTALL ALL REQUIRED CLASS "E" CONTROL WIRING. ALARMS AND SPEAKERS REQUIRED BY CODE AND BUILDING RULES AND REGULATIONS ALL CLASS "E" WORK SHALL BE COORDINATED WITH LANDLORD AS REQUIRED. (SEE ENGINEERING PLAN). ALL CLASS "E" WORK SHALL COMPLY WITH LOCAL DEPARTMENT OF BUILDINGS AND OR ANY SUCCESSOR LAW OF LIKE IMPORT AND BUILDING RULES AND REGULATIONS. 17. ALL CORE AND OR FLOOR TRENCHING FOR TELEPHONE / ELECTRICAL CONDUITING SHALL BE PERFORMED ON OVERTIME AS REQUIRED AND COORDINATED WITH LANDLORD FOR APPROVAL. 18. FOR ALL ELECTRICAL CONDUITS THAT MUST BE RUN IN CEILING OF FLOOR BELOW MUST BE IN RIGID CONDUIT OR EMT WITH NO JUNCTION BOXES WITHIN THIS FLOOR. 19. ALL LOW TENSION CABLING RUN THROUGH POKE-THRU ASSEMBLIES TO FLOOR BELOW SHALL BE IN EMT CONDUIT (SEPARATE CONDUITS FOR TELEPHONE AND COMPUTER CABLES). 20. ALL CONDUITS SHALL BE 4" O.C. MINIMUM AND SHALL BE PROPERLY HUNG FROM STRUCTURE ABOVE WITH KINDORF CHANNELS APPROPRIATELY SIZED HANGER RODS AS PER NATIONAL ELECTRIC CODE AND LOCAL DEPARTMENT OF BUILDINGS HAVING JURISTICTION OVER THIS PROJECT'S ELECTRICAL CODES. ALL LOW TENSION CABLE CONDUITS SHALL BE SUPPLIED WITH POINT TO POINT DRAG LINES TAGGED AT EACH END. THERE SHALL BE NO JUNCTION OR PULL BOXES IN THE FLOOR BELOW. 21. ALL POKE -THROUGH ASSEMBLIES SHALL BE FIRE RATED TYPE AS MANUFACTURED BY O.Z. GEDNEY OR APPROVED EQUAL AND SHALL BE FIRE STOPPED TO MAINTAIN FIRE RATING AS PER LOCAL DEPARTMENT OF BUILDINGS HAVING JURISDICTION OVER THIS PROJECT. 22. THE G.C.'S HVAC AND ELECTRICAL SUBS SHALL SUBMIT SHOP DRAWINGS AND SPECIFICATIONS COVERING ALL ITEMS FOR IA DESIGN INTENT APPROVAL PRIOR TO CONSTRUCTION. 23. ALL DUPLEX RECEPTACLES AND OTHER OUTLETS IN WALLS WITH SPECIAL APPLIED FINISHES (WOOD PANELING, CORK, ETC.) SHALL HAVE THE FACE OF THE ROUGHING BOX SET FLUSH WITH FACE OF APPLIED FINISH. SEE ELEVATIONS DRAWINGS. 24. WHERE OUTLETS, JUNCTION BOXES ARE LOCATED BEHIND CABINETS, THE CONTRACTOR SHALL PROVIDE FOR ACCESS TO THESE BOXES IF DESIGN APPEARANCE, STRUCTURE OR FUNCTION OF CABINET IS NOT IMPAIRED. WHEREVER A QUESTIONABLE CONDITION ARISES IA SHALL BE NOTIFIED PRIOR TO COMMENCEMENT OF WORK. 25. THE CONTRACTOR SHALL COORDINATE ANY ELECTRICAL WORK OR LIGHTING INSTALLATION INTO CABINET WORK IF AND AS REQUIRED. 26. G.C. TO PROVIDE PULL STRINGS IN ALL EMPTY CONDUIT. HARDWARE NOTES 1. LOCKSETS: ALL LOCKSETS SHALL BE MORTISE TYPE. STRIKES TO BE CURVED WITH BOX CONSTRUCTION AND HAVE LIPS OF SUFFICIENT LENGTH TO CLEAR TRIM AND PROTECT CLOTHING. 2. KEYING OF CYLINDER LOCKS SHALL BE COORDINATED WITH THE OWNER, FOR ESTIMATE USE GRANDMASTER KEYING CHARGE. UNDER OWNER'S DIRECTION, KEY TO NEW OR EXISTING SYSTEM TO BE APPROVED BY OWNER'S REPRESENTATIVE IN WRITING. FURNISH CONSTRUCTION KEY SYSTEM WITH KEYS WHICH CAN BE RENDERED INOPERATIVE BY THE TURN OF THE CHANGE KEY. STAMP ALL KEYS "DO NOT DUPLICATE". 3. FOR PROTECTION OF THE OWNER ALL LOCKS AND CYLINDERS SHALL BE KEYED AT THE FACTORY OF THE LOCK MANUFACTURER WHERE PERMANENT RECORDS ARE MAINTAINED. 4. HINGES: ALL HINGES OPEN WIDTHS SHALL BE MINIMUM, BUT OF SUFFICIENT SIZE TO PERMIT DOOR TO SWING 180 DEGREES 5. FURNISH TWO PAIR HINGES PER LEAF, U.O.N. FURNISH HINGES WITH STAINLESS STEEL PINS AND CONCEALED BEARINGS. SIZE LISTED IN HARDWARE SETS INDICATE HEIGHT. 6. SURFACE DOOR CLOSERS: TO BE OF FULL RACK AND PINION TYPE WITH REMOVABLE NON-FERROUS CASE AND CAST IRON BODY, COMPLETE WITH BOLTS AND GROMMETS. PLACE CLOSER INSIDE BUILDING, STAIRS, ROOMS, ETC. CLOSERS SHALL BE NON - HANDED, NON -SIZED AND ADJUSTABLE FROM SIZE 2 THROUGH 6 U.N.O. 7. SILENCERS: FURNISH SILENCERS FOR INTERIOR HOLLOW METAL FRAMES, 3 FOR SINGLE DOORS, 4 FOR PAIR OF DOORS. OMIT WHERE SOUND OR LIGHT SEAL OCCURS. 8, SCREWS: ALL EXPOSED SCREWS SHALL BE PHILIPS HEAD. HARDWARE LOCATIONS FOR INSTALLATION HINGES: BOTTOM HINGE = 10" FROM DOOR BOTTOM TO BOTTOM OF HINGE. TOP HINGE = 5" FROM TOP OF DOOR TO TOP OF HINGE. CENTER HINGE = CENTER BETWEEN TOP AND BOTTOM HINGE EXTRA HINGE = 6" FROM BOTTOM OF TOP HINGE TO TOP OF EXTRA HINGE. 9. LOCK: 38" FROM BOTTOM OF DOOR TO CENTER OF LEVER. INSTALLATION: A. INSTALL EACH HARDWARE ITEM PER MANUFACTURERS INSTRUCTION AND RECOMMENDATIONS. DO NOT INSTALL SURFACE MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON THE SUBSTRATE. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND AND OPERATION. B. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT, REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY. SAFETY GLAZING SECTION 2406 - SAFETY GLAZING 2406.2 IDENTIFICATION. EACH LIGHT OF SAFETY GLAZING MATERIAL INSTALLED IN HAZARDOUS LOCATIONS AS DEFINED IN SECTION 2406.4 SHALL BE IDENTIFIED BY A PERMANENT LABEL THAT SPECIFIES THE LABELER, WHETHER THE MANUFACTURE=R OR INSTALLER, AND STATE THAT SAFETY GLAZING MATERIAL HAS BEEN UTILIZED IN SUCH INSTALLATION. FOR ADDITIONAL IDENTIFICATION, REQUIREMENTS AND FOR INFORMATION ON SIZE AND USE BY CATEGORY CLASSIFICATION. EACH UNIT OF TEMPERED GLASS SHALL BE PERMANENTLY IDENTIFIED BYT THE MANUFACTURER. THE IDENTIFICATION SHALL BE ETCHED OR CERAMIC FIRED ON THE GLASS AND BE VISIBLE WHEN THE UNIT IS GLAZED. TEMPERED SPANDREL GLASS IS EXEMPTED FROM PERMANENT LABELING BUT SUCH GLASS SHALL BE IDENTIFIED BY THE MANUFACTUTER WITH A REMOVABLE PAPER LABEL. 2406.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED IN SECTION 2406.4, INCLUDING GLAZING USED IN FIRE ASSEMBLIES IN ACCORDANCE WITH SECTION 713, SHALL PASS THE TEST REQUIREMENTS. EXCEPTIONS: 1. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH SECTION 2405 NEED NOT COMPLY WITH SECTION 2406.3 2. POLISH WIRED GLASS COMPLYING WITH UBC STANDARD 24-2, PART II, MAY BE USED IN SMOKE AND DRAFT CONTROL AND FIRE ASSEMBLIES. PLASTIC GLAZING USED IN EXTERIOR APPLICATIONS ALSO SHALL COMPLY WITH THE WEATHERING REQUIREMENTS. 2406.4 HAZARDOUS LOCATION. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF GLAZING: 1. GLAZING IN INGRESS AND EGRESS DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SWINGING DOORS OTHER THAN WARDROBE DOORS. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1525 MM) ABOVE A STANDING SURFACE AND DRAIN INLET. 6. GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24 -INCH (610 mm) ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1525 mm) ABOVE THE WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCIRBED IN ITEMS 5 AND 6, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.84 m 2). 7.2 EXPOSED BOTTOM EDGE LESS THAN 18 INCHES (457 mm) ABOVE THE FLOOR. 7.3 EXPOSED TOP EDGE GREATER THAN 36 INCHES (914 mm) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 mm) HORIZONTALLY OF THE PLAN OF THE GLAZING. 8. GLAZING IN THE RAILINGS REGARDLESS OF HEIGHT ABOVE A WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTIONAI_ IN -FILL PANELS. EXCEPTIONS: THE FOLLOWING PRODUCTS AND APPLICATIONS ARE EXEMPT FROM THE REQUIREMENS FOR HAZARDOUS LOCATIONS AS LISTEN IN ITEMS 1 THROUGH 8: 1. GLAZING IN ITEM 6 WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 2. GLAZING IN ITEM 7 WHEN A PROTECTIVE BAR IS INSTALLED ON THE ACCESIBLE SIDES OF THE GLAZING 34 INCHES (864 mm) TO 38 INCHES (965 mm) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT (729 N/m) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 �/ INCHES (38 mm) IN HEIGHT. 3. OUTBOARD PANE IN INSULATING GLASS UNITS AND IN OTHER MULIPLE GLAZED PANELS IN ITEM 7 WHEN THE BOTTOM EXPOSED EDGE OF THE GLASS IS 25 FEET (7620 mm) OR MORE ABOVE ANY GRADE, ROOD, WALKING SURFACE, OR OTHER HORIZONTAL OR SLOPED (WITHIN 45 DEGREES OR HORIZONTAL) SURFACE ADJACENT TO THE GLASS EXTERIOR. 4. OPENINGS IN DOOR THROUGH WHICH A 3 -INCH DIAMETER (76.2 mm) SPHERE WILL NOT PASS. 5. ASSMEBLIES OF LEADED, FACETED OR CARVED GLASS IN ITEMS 1,2,6 AND 7 WHEN USED FOR DECORATIVE PURPOSES. 6. CURVED PANELS IN REVOLVING DOOR ASSEMBLIES. 7. DOORS IN COMMERCIAL REFRIGERATED CABINETS. 8. GLASS BLOCK PANELS COMPLYING WITH SECTION 2110. 9. GLAZING IN WALLS ENCLOSING STAIRWAY LANDINGS OR WITHIN 5 FEET (1525 mm) OF THE BOTTOM AND TOP OF STAIRWAYS WHERE THE BOTTOM EDGE OF THE GLASS IS LESS THAN 60 INCHES (1525 mm) ABOVE A WALKING SURFACE. DOOR NOTES 1. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 2, HAND -ACTIVATED DOOR OPENING HARDWARE MUST BE MOUNTED BETWEEN 30 AND 44 INCHES ABOVE FINISH FLOOR. 3. THE SWEEP OF A DOOR CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3" FROM THE LATCH AS MEASURED FROM THE LEADING EDGE OF THE DOOR. 4. THE LOWER 10" OF THE DOOR SHALL BE A SMOOTH SURFACE (NO RECESS OR TRAP). 5. EXTERIOR LEVEL LANDING MAY SLOPE UP TO 1/4" PER FOOT IN ANY DIRECTION FOR SURFACE DRAINAGE. 6. DOOR HARDWARE SHALL BE OPENABLE WITH A SINGLE EFFORT WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE (LEVER OR PUSH TYPE IS ACCEPTABLE PER CBC SECTION 1004.3.1. 7. EFFORT TO OPERATE DOORS IS WITHIN PRESSURES ALLOWED. INTERIOR DOORS- 5 LB. MAX. PRESSURE TO OPERATE. EXTERIOR DOORS- 8 1/2 LB. MAX. PRESSURE TO OPERATE. FIRE DOORS- 15 LB. MAX. PRESSURE TO OPERATE. 8. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY. BEVEL (1:2 MAX. SLOPE) WHERE THE THRESHOLD EXCEEDS 1/4" IN HEIGHT. 9. DOOR OPENING IN PARTITION NOT DIMENSIONED ARE TO BE LOCATED WITHIN 4" OF ADJOINING PARTITION. 10. (E) DESIGNATES DOORS THAT ARE EXISTING. DOORS TO EXTERIOR OF BLDG. ARE NOT FIRE RATED CONSTRUCTION. RECORD DRAWINGS AT THE COMPLETION OF THE CONSTRUCTION WORK THE GENERAL CONTRACTOR SHALL DELIVER TO THE ARCHITECT AND ENGINEER (IF APPLICABLE) A SET OF LEGIBLE REPRODUCIBLE RECORD DRAWINGS AND ELECTRONIC DOCUMENTS IN AUTO CAD WHICH SHALL SHOW ALL CONSTRUCTION CHANGES IN THE CONSTRUCTION WORK AND THE FINAL LOCATION OF ALL MECHANICAL EQUIPMENT, UTILITY LINES, DUCTS, AND OUTLETS APPROPRIATELY NOTED. WEEKLY STATUS REPORTS THE CONTRACTOR TO PROVIDE A WEEKLY STATUS REPORT INDICATING ESTIMATED PERCENTAGE OF COMPLETION FOR EACH TRADE INCLUSIVE OF DIGITAL PHOTOGRAPHS AS SUPPORTING INFORMATION. REPORT AND IMAGES ARE TO BE SENT VIA E-MAIL TO THE IA PROJECT MANAGER AND IA ARCHITECT OF RECORD OF THE SALIENT AREAS OR WORK. THE NUMBER AND LOCATIONS OF PHOTOS TO BE DETERMINED PREAGREEMENT BY THE IA ARCHITECT OF RECORD. Liberty,mut I'm. INDIANA INSURANCE 350 EAST 96TH STREET INDIANAPOLIS, IN. FIRST FLOOR 2 ISSUE FOR PERMIT 06/14/04 1 ISSUE FOR PRICING 06/11/04 Issue Description Date �P.N' VJ'JE- °L. LFFhl, - - - Drawn: DM Check: KSY Owner No: 5413200 Scale: AS NOTED Title: GENERAL NOTES Sheet: X� Y INTERMEDIATE LANDINGS SHALL BE PROVIDED 60" MIN. 60" MIN. 12"min AT INTERVALS NOT EXCEEDING 317 OF _- � VERTICAL RISE A AT EACH CHANGE OF - DIRECTION 'E Push Side 00 Pull Side Pull Side 11 -_ ... Libe I� -mak 54" min. � z �I �"" 7 1 01 01 �- �` A A o 1:12 MAX. SLOPE E Mutuaf,. FRONT APPROACH 18 min. �i - f HANDRAIL REQUIRED IF SLOPE EXCEEDS 1:20 E o 54" min. N ° 24' preferred f - NOTE: rty, y X IS THE 12" MINIMUM HANDRAIL EXTENTION AT BOTTOM OF RUN RAMP NOTE: X=36" min. if Y=60" NOTE: Y=48" min. if door EXTENSION REQUIRED AT EACH o E X=42" min. if Y=54" has both a closer and latch. FRONT NMNG DOORS TOP RISER. INDIANA INSURANCE r� a „ N NOTE: all doors in alcoves shall comply 12 MIN. 350 EAST 96TH STREET HINGE SIDE APPROACHES -SWINGING DOORS with the clearances for front approaches. Y IS THE MINIMUM HANDRAIL - 48" MAX.. 7�7:d - I EXTENSION OF 12' PLUS THE N -- ""°T" INDIANAPOLIS IN. X X X WIDTH OF ONE TREAD THAT � �2 Mme. SLIDE SIDE APPROACH X 24" min. 24" min. f IS REQUIRED AT EACH BOTTOM RISER. � 'k- WIDTH MUST BE a BE OF 60" WITH tip, Push Side OCCUPANCY OF 24" min. � FIRST FLOOR 300 OR MORE. NC7 LEVEL LEVEL E E E LANDING r LANDING Nrr. N GUIDED RAIL GUIDED RAIL 00 V REQUIRED OREIRTHAN ra M NOTE: Y=54" min. NOTE: Y=48' min. RAILING AT RAMP if door has closer. if door has closer. /E LATCH SIDE APPROACH LATCH SIDE APPROACFIEB-SWINGING DOORS NOTE: X=12 if door has both a closer and latch. EXTENTION AT TOP OF MM SECTION � RAMP 1 MANEUVERING DOORS AT MANEUVERING CLEARANCES AT STAIR HANDRAILS SOMA Ve. rar 1 RAMP/ PROJECTIONS OF HADRAILS Sam& ILTi �� GOMM ve • *� 17 SLIDING/FOLDING DOORS °CATV' • 11W � � " �� � �� � S 3 SLIDING/FOLD ree� i t 48"min 2" WIDE MIN. CONTRASTING ) LEVEL 48" min. ' STRIPING ® 1" MAX. FROM LANDING ° - NOSING. TYP. AT EVERY SURFACE OF RAMP LEVEL LANDING / TRANSITION f ••••• -- —_ •••• 36" 48" 36" � � ! NOTE: � � � INT. VOLUME CONTROL seems � CONSTITHE OTOE LEGAL STANDARDSITIONS ILLUSTRATED FOR HIS SHEET HANDICAPPED TABLE/COUNTER ROUTE FOR 90 TURN TELEPHONE SYMBOL ACCESSIBILITY. THEY DO NOT CONSTITUTE ACTUAL HEIGHT: ARCHITECTURAL CONDITIONS FOR CONSTRUCTION IN THE " MINIMUM PASSAGE WIDTH FOR ONE -- COURSE CE THIS WORK. SEE ENCLOSED ARCHITECTURAL 28 MIN. TO WHEELCHAIR AND ONE AMBULATORY PERSON _ + INTERNATIONAL � SYMBOL HORIZONTAL PROJECTION_ DRAWINGS FOR ACTUAL EXTENT OF WORK. NOT ALL STAIR RISER/ TREADS 34 MAX OR RUN CONDITIONS SHOWN HERE NECESSARILY OCCUR IN THIS PROJECT. 19" MIN. 78"min -- CONTRACTOR TO INFORM ARCHITECT WHEN DUE TO FIELD CONDITIONS, ETC., ACTUAL CONSTRUCTION WILL 27" MIN. UNOBSTRUCTED - NOT CONFORM TO THESE STANDARDS. KNEE SPACE 48" min. E = Slope Maximum Rise Maximum Horiz. Projection 00 11"min. 1,/2'max. E 1 2 max. 1 a) PROPORTIONS 2 Max.max. FLOOR LINE 1:12 to < 1:16 30 30'-0" �— � ID RADIUS RADIUS RADIUS � 1:16 to < 1:20 30 40'-0" 42" min X 4 2"min INTERNATIONAL SYMBOL SPACE NEEDED FOR SMOOTH OF ACCESS FOR WIDTH OF ACCESSIBLE ROUTE FOR U-TURN IN A WHEELCHAIR FLUSH RISER ANGLED NOSING ROUNDED NOSING b) DISPLAY CONDITIONS FOR HEARING LOSS TURNS AROUND AN OBSTRUCTION INTERNATIONAL. SYMBOL OF ACCESSIBILITY 18 FIXED COUNTER/ HEIGHTS 14 TWO HINGED DOORS IN SERIES .rx�ve•ra 10 ACCESIBLE ROUTES SWAM � 7 USABLE TREAD WIDTH AND EXAMPLES ewmwie.*•Q KT 9 INTERNATIONAL SYMBOLS 2 COMPONENTS OF A SINGLE RAMP RUN WAr�ve"1a OF ACCEPTABLE NOSINGS K a AND SAMPLE RAMP DIMENSIONS 3' HIGH Q 3'-6" MIN. SIGNAGE SIGNAGE TO COMPLY WITH ADA REQUIREMENTS STARTING POINT BLUE PAINTED PREMANUFACTURED SIGN TO COMPLY W/ THE 2. -FINAL GRAPHICS TO BE APPROVED BY ARCHITECTS H.C. EMBLEM, TYP. MANUAL OF UNIFORM - 3.- TEMPORARY SIGNAGE TO BE SUPPLIED BY OWNER E 4.- PROVIDE METAL SIGNS AS NOTED. TRAFFIC CONTROL DEVICES PARKING STANDARD NO. R7-8. A METAL BASE WITH RAISED LETTERING AND o, INSTALL CONCRETE 15 BUMPERS, TYP. BRAILLE WHERE REQUIRED. o ONLY B. SIZE: MINIMUM 1/16" THICK X LENGHT AND 2' HIGH /8' HIGH TYP, C° SUPPORT STANDARD 3" HEIGHT AS INDICATED. z -� - DIA. STEEL POLE W/ D. TEXT AND LETTER STYLE AS INDICATED, ACID STAIR ---- " ETCHED GRAPHICS TO CONFORM TO ADA REQUIREMENTS C. EDGE PROFILE. SQUARE. _j Q C H. C • VAN STALL) < — - - 2 -0 IMBEDMENT ATTACH �-o- _ - 2 Q �I-1= (BRAILLE) � w `� ❑❑❑❑❑❑❑❑❑❑o❑❑❑❑ CURB, MATCH <E> o STRAPS A TOP &BOTTOM. f - TO COLOR N0. 15090 IN FRAME: TO BE DETERMINED BRAILLE -6„ Q Q _ ❑ 2' HIGH MIN PROVIDE SIGN W/ POST ILLIJ / a +,�, +,�, 2 WIDE BLUE LINES EQUAL E. FINISHES ., U) o ❑ INDICATING H.C. PARKING 29-091 H FEDERAL STD. 595A, TYP. PLAQUE. TO BE DETERMINED ( ) _ LOCATION, TYP. 19/AN-3 M + F. MOUNTING: CONCEALED ❑ CD H zG. ACCEPTABLE PRODUCT: 3 -- STAIRWELL SIGN 1 Q Z Y R=2-1/2"WHITE BACKGROUND, TO SERIES 322 FRAME. O m ~ ❑ O �I 01!_ D TYP. Q ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ +/2' PROVIDE CONCEALED FASTENERS OR ADHESIVES AS RECOMENDED w O J H.C. SIGNAGE +/� BY MANUFACTURERS AND AS REQUIRED FOR PERMANENT AND ELEVATOR N o U o t f ;'�t 5. SECURE MOUNTING TO SUBSTRATES INDICATED. SUITABLE FOR FLOOR SIGN o > � PREMANUFACTURED SIGN z CONDITIONS OF APPLICATION AND USEft�O L_jQ o TO COMPLY W THE W- x OPTION: Ct Under Smoking o cn / USE COMMERCIALLY MANUAL OF UNIFORM - AVAILABLE STENCIL Penalty PLAN (H.C. STALL) TRAFFIC CONTROL DEVICES 3 APPROX. THESE CRITERIA. o" I of LI o ❑❑❑❑❑❑❑❑❑❑❑❑ ❑ STANDARD NO. R7-8, MIN. � � PARKING SIZE 70 SQ. IN. I -IJ _ OPTION: ONLY PROVIDE VAN ACCESSIBLE ¢ y PAINT FIGURE IN WHITE ❑ �' 0 2 ISSUE FOR PERMIT 06/14/04 AC ;IBL INSCRIPTION ® VAN STALL x LINE ON 3x3 BLUE eRaLLE -\i—STRIPING, PROVIDE WHITE STALL - LOCATIONS BACKGROUND (BRAT ) ( ) Q 1 ISSUE FOR PRICING 06/11/04 SUPPORT STANDTARD 3" ,•_r ,_�- -- � In case of fire TYP. (H.C, STALL) M use stairs ❑❑❑��❑S�=�❑ DIA. GALV. STEEL POLE W/ 0 4, 4„ UnIe88��'� r#• ❑ Issue Description Date � j 2'-0" INBEDMENT ATTACH i instructed � -� � 2' HIGH MIN. Q SIGN TO POLE W/ GALV. N.A. 0 I STRAPS AT TOP & BOTTOM DIRECTIONAL DIRECTIONAL 18_'_0"_1 HEIGHT WHEN LOCATED IN SIGN 1 SIGN 2 � - MIN. PATH OF TRAVEL 10" ❑ S Hi. VAN SIGNAGE - � MATCH <E> 2O TOILET STALLS/ GRAB BARS � ve • *-w 19 HANDICAPPED PARKING SIGN waa ve. r� 15 HANDICAPPED SYMBOL N.T� 8 SIGNAGE LOCATION KTA 12 EVACUATION SIGNAGE 11 PARKING LAYOUT (FOR REFERENCE ONLY 5/32„ 1/4" RADIUS, TYP. TYP. 10" O � 1 0 0 FOL'3 =�� 36"min 54"min ---- -- - x p = 1/2"-7"< o O � � -- f 4" n 12 42min D = r LO Wm1/4" RADIUS, TOP I I I I I TYP. - FLR. FIN. - - - ;,� c- _ - - -- = L� � O O O O 2'-0" STD. - '�E - SURFACE SANITARY NAPKIN/ PAPER TOWEL TOILET TISSUE 2-10 HCP. - - - E TAMP DISPENSER AND- � I i � �� MOUNTED ON VENDOR DISP &SEAT COVER O <R> - S.N.D. WITH DISPOSAL WASTE RECEPTACLE DISPENSER o �' - !, a- �Ert - COUNTER TOP ROBE HOOK TOILET URINAL SCREEN 1 SOAP DISPENSER COMPARTMENTLj CD HANDICAP (SEE SCHEDULE) OP HOLDER * EQ' EQ. 3 - E0. - - EQ. * 3 STALL FLUSH VALVE -M CD, 12" , T 1'- z 2 WIDE SIDE " „ 1 -7 MAX. 1 -5 MIN. C) MIN. Q 8 MIN; RAG HOOK MENS ROOM WOMEN'S ROOM o X w I X z z Q�amx< DOOR DOOR Drawn GM Check: KSY Owner Approval: 36"min _ — —DRYING ROD z _ II inL_ M �/z _ 1 RESTROOM IDENTIFICATION - 1/4 ° ETCHED MAGNESIUM ALLOY WITH RAISED LETTERS AND BRAILLE, PAINTED WITH MATTE PAINT. 40" (4 ") min - - O : I - - O lob No: 54132.00 Scale: AS NOTED 121' m a � _ _ X j� u7 d Orn O M in to 'It z -- - I r Q I I I O I I I I I = I O PANEL'MTH EITHER THE SYMBOL OF ACCESSIBILITY OR DIRECTIONAL SIGNAGE - 1/4 " ACRYLIC SURFACE PAINTED WITH MATTE PAINT. i� �� cV N iv j N =- - O RESTROOM IDENTIFICATION SYMBOL -MATTE EPDXY INK. COLOR -BLACK 3 max to - r - o6" MAX. MOP/BROOM HOLDER ,� ,.� _�� E •� F1 O O OJ O O 2 SYMBOL BACKGROUND -1/4 °THICK MATTE ACRYLIC BACK PAINTED. ® INSULATE HOT AND COLD "' DRINKING WATER SUPPLY AND DRAIN O EASED EDGES- TYPICAL TOILET SEAT COVER UR -2 WC -2 GRAB BAR MIRROR a DISPENSER FOUNTAIN PIPES. BOBRICK KIT C50OR STANDARD ' STANDARD .ONLY O ADA NOTES o $T� O TOILET TISSUE SIGN @DOORS SIGN @WALL Title: LAV -1 DISPENSER 0 & S.N.D. o 16 GRAB BARS 10 MOUNTING HEIGHT SCHEDULE 4 SIGNAGE AT RESTROOMS Sheet. A N I DEMOLITION PLAN NOTES 1. SEE DWG. AN -2 FOR ADDITIONAL NOTES. 2. G.C. SHALL OBTAIN AND FURNISH ALL LICENSES AND SPECIAL INSURANCE PRIOR TO THE START OF DEMOLITION WORK. 3. G.C. TO COORDINATE WALK THRU WITH ARCHITECT PRIOR TO COMMENCEMENT OF WORK FOR EXACT SCOPE OF WORK AND ALL CLARIFICATIONS REQUIRED. 4. G.C. TO COORDINATE DEMOLITION OF HVAC/MECHANICAL, PLUMBING, FIRE PROTECTION & ELECTRICAL SCOPE OF WORK WITH ENGINEER'S DWGS. 5. BECAUSE OF THE EXISTING PRESENCE OF MOLD, ALL CONTRACTORS SHALL TAKE THE NECESSARY PRECAUTIONS DURING THE REMOVAL PROCESS. 6. G.C. SHALL TAKE NECESSARY PRECAUTIONS TO PROTECT ADJACENT CONSTRUCTION 7. REMOVE ALL CABLE IN CLG. BACK TO SOURCE OF DATA COMMUNICATION CLOSETS, AS REQUIRED. 8. REMOVE EXISTING DOORS, DOOR FRAMES, TRIM AND HARDWARE THROUGHOUT ONLY AS INDICATED. 9, PROTECT EXISTING THERMOSTATS TO REMAIN. THERMOSTATS TO REMAIN OPERATIONAL WHERE POSSIBLE, 10. ANY EXISTING ELECTRICAL PANELS AND CONDUITS, ETC., TO BE RELOCATED AS REQUIRED, REFER TO ENGINEERING DRAWINGS FOR EXTENT OF RELOCATION. 11. EXISTING ELECTRICAL OUTLETS LOCATED ON PARTITIONS TO BE DEMOLISHED ARE TO BE REMOVED, INCLUDING ALL CONDUIT AND WIRING BACK TO THEIR RESPECTIVE ELECTRICAL PANELS. PATCH AND REPAIR AS REQUIRED. 12, EXISTING FIRE ALARM DEVICES TO REMAIN OPERATIONAL. G.C. TO PROTECT ALL PULLS, ALARMS, STROBES AND ASSOCIATED DEVICES. 13. ALL EXISTING STAND PIPES, FIRE HOSES, FIRE HOSE CABINETS TO REMAIN, U.O.N. PROTECT AS REQUIRED DURING DEMOLITION. 14. WHERE INDICATED ON PLAN, REMOVE OUTLETS ON EXISTING WALL BACK TO SOURCE. PATCH EXISTING WALL. TAPE AND SPACKLE SMOOTH AS REQUIRED. 15. REMOVE EXISTING PARTITIONS/PORTIONS OF PARTITIONS THROUGHOUT ONLY AS NOTED. PROTECT ADJACENT CONSTRUCTION. 16. EXISTING PERIMETER WINDOWS AND FRAMES TO REMAIN AS SHOWN, PROTECT DURING DEMOLITION. 17. G.C. TO SALVAGE AND PROTECT REMOVED WINDOW BLINDS FOR REUSE, IF APPLICABLE, 18. DASHED LINES INDICATE EXISTING CONSTRUCTION TO BE REMOVED. REMOVE ALL EXISTING CONSTRUCTION WHICH CONFLICTS WITH THE INTENT OF THE NEW CONSTRUCTION. 19. ALL MEP ITEMS CONTAINED IN THE WALL OR CEILING, IF NOT NOTED ON MEP DRAWINGS, SHALL BE BROUGHT TO THE ATTENTION OF BUILDING OWNER'S REPRESENTATIVE. 20. WHERE EXISTING DOORS, DOOR FRAMES, EQUIPMENT, WALLS OR PORTIONS OF WALLS ARE INDICATED TO BE REMOVED, THE CONTRACTOR SHALL EXERCISE CAUTION TO AVOID DISRUPTING SURROUNDING MATERIALS. 21. ALL NOTICEABLE DEFECTS IN THE EXISTING CONSTRUCTION WILL BE BROUGHT TO THE ATTENTION OF THE BUILDING OWNER PRIOR TO THE COMMENCEMENT OF DEMOLITION. ALL DEFECTS IN THE EXISTING CONSTRUCTION UNCOVERED DURING DEMOLITION WILL ALSO BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE BUILDING OWNER'S REPRESENTATIVE. 22. ESTABLISH TRASH REMOVAL ARRANGEMENT WITH THE BUILDING MANAGEMENT PRIOR TO START OF CONSTRUCTION. TRASH REMOVAL IS THE RESPONSIBILITY OF THE CONTRACTOR. 23. CONTRACTOR SHALL NOT REMOVE ANY FIRE SAFING FROM BUILDING STRUCTURE DURING MOLD ABATEMENT WITHOUT FIRST NOTIFYING THE ARCHITECT. IF DIRECTED TO PROCEED UPON NOTIFYING ARCHITECT, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETELY REPLACING ALL EXISTING FIRE PROOFING AND VERIFYING THAT ALL FIRE PROOFING IS PRESENT AS REQUIRED BY APPLICABLE CODES. 24. CONTRACTOR SHALL EXAMINE AND PERFORM MOLD ABATEMENT AT ALL EXISTING DUCTWORK. DEMOLITION PLAN DEMOLITION —LEGEND EXISTING CONSTRUCTION TO REMAIN - --_ - EXISTING CONSTRUCTION TO BE REMOVED EXISTING DOOR, DOOR FRAME, TRIM & HARDWARE TO REMAIN. - EXISTING DOOR, DOOR FRAME, TRIM & HARDWARE TO BE REMOVED AS APPLICABLE. SAVE & PROTECT AS REQUIRED FOR REUSE OR STORE FOR FUTURE USE GENERAL NOTES 1. NOT USED SHEET NOTES O PREP FLOOR TO RECEIVE NEW (MPET IN THIS AREA. O EXISTING CARPET, VINYL BASE, AND PAINT TO REMAIN. PATCH AND REPAIR BASE BUILDING FINISHES AT DEMOLITION, O EXISTING VCT TO REMAIN IN THIS AREA. ® PREP WALL TO RECEIVE NEW FINISH. REFER TO FINISH PLAN (SHEET 01A-4.0) FOR FINISH SPECIFICATIONS. O CONTRACTOR TO REMOVE ALL PLUMBING BACK TO THE SOURCE. © CONTRACTOR TO REMOVE AND STORE ELECTRICAL PANEL FOR RELOCATION. O7 CONTRACTOR TO REMOVE EXISTING CARPET IN THIS AREA. CONTRACTOR TO COORDINATE RFMOVAL WITH PARTITION PLAN. PREP FLOOR TO RECEIVE NEW FINISH. REFER TO THE FINISH PLAN (SHEET 01A-4.0) FOR FINISH SPECIFICA(IONS. Liberty,Mutua.. INDIANA INSURANCE 350 EAST 96TH STREET INDIANAPOLIS, IN. FIRST FLOOR 2 ISSUE FOR PERMIT 1 ISSUE FOR PRICING 06/14/04 06/11/04 Issue Description Date IA Drawn: DM Check: KSY No: 54132.00 Owner Scale: AS NOTED DEMOLITION T;t,e P LA N Sheet: ■ PARTITION PLAN NOTES 1. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. ALL PARTITION LOCATIONS SHALL BE AS SHOWN ON PARTITION PLAN. IN CASE OF CONFLICT NOTIFY ARCHITECT. PARTITION PLAN BY ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS. 2. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED. ALL SURFACES SHALL BE ALIGNED AND SANDED SMOOTH. 3. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES, U.O.N. 4. DIMENSIONS NOTED "CLEAR" OR "CLR" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. 5. DIMENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.O.N. VERIFY FIELD DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE ARCHITECT'S APPROVAL. 6. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE INSIDE FACE OF SILL, U.O.N. 7. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN THE LOCATIONS) OF NEW CONSTRUCTION. UPON COMPLETION OF PARTITION OF THE LAYOUT, NOTIFY THE ARCHITECT. VERIFICATION OF THE LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION INSTALLATION 8. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM. 9. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE, AND IN PROPER ALIGNMENT. 10. REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND PLENUM BARRIER LOCATIONS. 11. REFER TO SHEET AN -1 AND AN -2 FOR ADDITIONAL NOTES, LEGENDS, SYMBOLS, ABBREVIATIONS, AND SCHEDULES. 12. OBTAIN APPROVAL FROM ARCHITECT PRIOR TO MODIFYING COLUMN FURRING, RELOCATING PIPES AND SIMILAR SYSTEMS AND ITEMS, ADJUSTING ANY AND ALL OTHER FIELD CONDITIONS REQUIRED TO FIT PLANS. 13. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR PIPING SHALL BE FULLY PACKED AND SEALED IN ACCORDANCE WITH THE APPLICABLE BUILDING AND FIRE CODES. 14. TRIM THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED FLOOR, AS APPLICABLE, BY 1/4" INCH MAXIMUM, UNLESS OTHERWISE NOTED. VERIFY SLAB CONDITIONS. TRIM EACH DOOR TO FIT CONDITION. WHERE RADICAL VARIATIONS IN FLOOR ELEVATION EXIST, DOORS SHALL BE ORDERED WITH BOTTOM STILE SIZED TO ACCOMODATE THESE UNDERCUT CONDITIONS. 16. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. 17. ALL DOORS SHALL HAVE 1'-6" CLR. ON STRIKE/PULL SIDE OF DOOR. VERIFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. 18. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOORS/FRAMES 19. REFER TO POWER & SIGNAL AND REFLECTED CEILING PLANS FOR LOCATIONS OF SWITCHES, OUTLETS AND THE LIKE TO BE REMOVED. PATCH AND REPAIR PARTITION 20. ALL GLASS SHALL BE CLEAR TEMPERED GLASS, UNLESS OTHERWISE NOTED. GLAZING TONG MARKS SHALL NOT BE VISIBLE. CLEAN AND POLISH ALL GLASS PRIOR TO PROJECT DELIVERY. 21. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. U.O.N. 22. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN WALLS AS REQ'D WHERE MILLWORK AND WALL MOUNTED ACCESSORIES OCCURS. 23. PATCH, REPAIR, OR REPLACE AS REQUIRED FIRE PROOFING ON BASE BUILDING STRUCTURE EITHER DURING THE PERFORMANCE OR MISSING OR DAMAGED. 24. ALL PIPING, CONDUIT AND DUCT PENETRATIONS AT FIRE RATED ASSEMBLIES SHALL BE UL APPROVED FOR FIRE RATED ASSEMBLY. DOOR TYPE BUILDING STANDARD H.M. FRAME AND WOOD DOOR CO� (2) 3'-0" BUILDING STANDARD DOOR BUILDING STANDARD DOOR FINISHES DOOR FRAME FINISH: TO MATCH EXISTING HARDWARE AS FOLLOWS: UANTITY DESCRIPTION 8 EACH BUTT HINGES 1 EACH PASSAGE FUNCTION LATCHSET WITH LEVER HANDLE 2 EACH DOME STYLE FLOOR STOP 6 EACH SILENCER 1 EACH DUMMY LEVER (INACTIVE LEAF) 1 SET FLUSH BOLT (INACTIVE LEAF) 1 EACH DUST PROOF STRIKE (INACTIVE LEAF) 01, PARTITION PLAN SYMBOLS �A PARTITION TYPE "A" — SEE 1, A-8.0 ALIGN SURFACES AS INDICATED a FIRE EXTINGUISHER FEC "E" DENOTES EXISTING 1/8"=V-0" PARTITION ANNOTATIONS -] NEW DOOR NEW PARTITION GLASS SIDELITE (WITH SILL) DOOR TYPE GENERAL NOTES 1. PARTITION DIMENSIONED TO FINISH FACE U.O.N. 2, SEE SHEET A8.1 FOR TYPICAL PARTITIONS DETAILS. 3. WHERE FURRED PARTITIONS EXCEED MAXIMUM HEIGHT, BRACE TO ADJACENT STRUCTURE, PER DETAIL. 4. FOR NON—RATED PARTITIONS, SEE DETAIL SHEET A8.1 FOR EXTENT OF FRAMING AND FINISHES. SHEET NOTES tLiberty,Mutual....,. INDIANA INSURANCE 350 EAST 96TH STREET INDIANAPOLIS, IN. FIRST FLOOR 2 ISSUE FOR PERMIT 06/14/04 1 ISSUE FOR PRICING 06/11/04 Issue Description Date IA Drawn: DM Check: KSY No: 5413200 15. CLG. HT. PARTITIONS SHALL BE INSTALLED TIGHT TO FINISHED CLG; WITH NO JOINTS VARYING MORE THAN 1/8" OVER 6'-0" EXISTING DOOR TO REMAIN PARTITION AND NO JOINTS GREATER THAN 3/16", U.O.N. Title: PLAN EXISTING PARTITION TO REMAIN Owner Scale: AS NOTED 0 Sheet: ■ POWER/COMMUNICATION PLAN NOTES 1. WHEN FLOOR BELOW IS OCCUPIED, PRICE FLOOR SLAB PENETRATIONS AND/OR CORING ON AN OVERTIME BASIS. 2. SURVEY FIELD CONDITIONS AND VERIFY THAT WORK IS FEASIBLE AS SHOWN. VERIFY LOCATION OF FLOOR OUTLETS AND OTHER OUTLETS IN RELATION TO STRUCTURAL AND OTHER ELEMENTS AS REQUIRED. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 3. ARCHITECTURAL DRAWINGS DETERMINE LOCATION AND TYPE OF ALL OUTLETS AND TAKE PRECEDENCE OVER ALL OTHERS, U.O.N.. ELECTRICAL ENGINEER'S POWER PLAN SHALL GOVERN THE WIRING LAYOUT AND INSTALLATION IN COMPLIANCE WITH ALL LAWS APPLICABLE AND ENFORCED BY GOVERNING AUTHORITIES. 4. OUTLETS SHOWN BACK TO BACK ON PARTITION WALLS SHALL BE OFFSET 1'-0", MAXIMUM, OR MOUNTED AT DIFFERENT HEIGHTS IF INDICATED. 5. FURNITURE, IF SHOWN, IS FOR REFERENCE ONLY AND IS NOT IN CONTRACT, U.O.N. 6. COORDINATE ALL WORK RELATED TO EQUIPMENT WITH MANUFACTURER'S RECOMMENDATIONS, SPECIFICATIONS AND INSTRUCTIONS. 7. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR CONDUIT SHALL BE FULLY PACKED AND SEALED IN ACCORDANCE WITH THE APPLICABLE BUILDING AND FIRE CODES. 8• VERIFY SELECTION AND CHOICE WITH THE ARCHITECT PRIOR TO ORDERING MATERIALS. 9. COORDINATE NEW ELECTRICAL WITH EXISTING, WHERE OCCURS. 10. UPON COMPLETION OF OUTLET LAYOUT, NOTIFY THE ARCHITECT. ARCHITECT SHALL SITE VERIFY ALL OUTLET LOCATIONS PRIOR TO COMMENCEMENT OF CORING OR OUTLET INSTALLATION. 11. FURNISH AND INSTALL UNDERWRITERS LABORATORIES, INC. (UL) LABELED DEVICES THROUGHOUT. 12. INSTALL WALL MOUNTED OUTLETS TO MATCH EXISTING HEIGHT, U.O.N. HEIGHTS SHALL BE DETERMINED FROM FINISHED FLOOR TO THE CENTERLINE OF COVERPLATE, INSTALLED VERTICALLY, GROUNDING POLE AT BOTTOM, U.O.N.. OUTLETS MOUNTED HIGHER THAN 27" SHALL BE INSTALLED HORIZONTALLY, GROUNDING POLE AT LEFT, U.O.N.. FOURPLEX OUTLETS TO BE INSTALLED VERTICALLY, U.O.N. POWER & COMMUNICATION PLAN 1/8"=I'- POWER/SIGNAL LEGEND 13. MAINTAIN A 4 -INCH HORIZONTAL CLEARANCE IN ALL DIRECTIONS, MIN. FROM EDGE OF COVERPLATE, FOR WALL MOUNTED OUTLETS, OR FROM EDGE OF MONUMENT FOR FLOOR MOUNTED OUTLETS, WHEN ADJACENT WALL MOUNTED DUPLEX OUTLET TO A WALL, COLUMN, OR SIMILAR ELEMENTS, U.O.N. kQ WALL MOUNTED DEDICATED OUTLET 14. INDICATED DIMENSIONS ARE TO THE CENTER OF THE COVERPLATE OR MONUMENT; CLUSTERS OF OUTLETS ARE DIMENSIONED TO THE CENTER OF THE CLUSTER, U.O.N.; WALL MOUNTED QUAD OUTLET GANG COVERPLATES SHALL BE ONE-PIECE TYPE, U.O.N.. NW WALL MOUNTED PHONE OUTLET 15. OUTLETS INSIDE AND/OR ATTACHED TO CABINETRY SHALL BE FURNISHED AND INSTALLED TO MATCH SIMILAR CONDITIONS SUCH AS WALL, FLOOR, AND THE LIKE. FURNISH AND INSTALL BOX EXTENSION OR OTHER APPROPRIATE DEVICES AS REQUIRED. ADJACENT OUTLETS SHALL NOT BE GREATER THAN 6" O.C. APART U.O.N. 16. ALL OUTLETS SHOWN ARE NEW, U.O.N. 17. NOT USED 18. G.C. TO PROVIDE CONDUIT & BACKBOXES FOR CARDREADERS. 19. CONTRACTOR TO PROVIDE AND INSTALL ONE 3/4" CONDUIT FOR EACH 4 PAIR OF CABLES REQUIRED AT WORKSTATION INFEED LOCATIONS. EACH WS42 TO RECEIVE 2 PAIR CABLES. EACH WS84 TO RECEIVE 4 PAIR CABLES. CABLING TO BE PROVIDED BY OTHERS. 20. REFER TO FURNITURE PLAN, 6A-5.0, FOR ADDITIONAL EQUIPMENT INFORMATION 21. GENERAL CONTRACTOR TO PROVIDE (3) 20 AMP CIRCUITS FOR EVERY FURNITURE INFEED; CIRCUITS ARE NOT TO BE SHARED BETWEEN FURNITURE INFEEDS UNLESS THE CLUSTERS ARE (4) WS42 OR (2) WS84 OR LESS AND THE JUMP DOES NOT EXCEED (8) WS42 OR (4) WS84 22, ALL DEVICES FOR DEDICATED CIRCUITS SHALL BE GRAY 14Q WALL MOUNTED TELEPHONE/DATA OUTLET POWER POLE (TO BE PROVIDED BY FURNITURE VENDOR). POWER/ VOICE/ DATA INFEED. • WALL MOUNTED POWER INFEED aC �• WALL MOUNTED TELE -COMMUNICATIONS INFEED FURNITURE MOUNTED VOICE/ DATA OUTLET FURNITURE MOUNTED DUPLEX OULET CARD READER ES ELECTRIC STRIKE +44" MOUNTING HEIGHT A.F.F. AS INDICATED E EXISTING DEVICE TO REMAIN GENERAL NOTES 1. ALL DEVICE AND COVER PLATES SHALL MATCH EXISTING 2. NOT USED 3. ALL DEVICES ARE NEW, U.O.N. 4. FURNITURE AND EQUIPMENT SHOWN IS FOR REFERENCE ONLY AND IS NOT IN CONTRACT 5. FURNITURE PANEL SYSTEM IS HERMAN MILLER PROSPECTS WITH 8 -WIRE, 4 -CIRCUIT SYSTEM; FURNITURE CONTRACTOR SHALL PROVIDE ALL PANEL MOUNTED DEVICES, RACEWAYS, HARNESSES AND POWER INFEEDS; POWER AND TELE -COMMUNICATION INFEED FROM WALL (•&) SHALL BE PROVIDED BY FURNITURE CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR 6. CONTRACTOR TO COORDINATE ALL FIRE AND LIFE SAFETY DEVICE LOCATIONS WITH FURNITURE LAYOUT; REFER TO 4A-5.0 AND 4A-5.1 7. GENERAL CONTRACTOR TO PROVIDE (3) 20 AMP CIRCUITS FOR EVERY FURNITURE INFEED; CIRCUITS ARE NOT TO BE SHARED BETWEEN FURNITURE INFEEDS UNLESS THE CLUSTERS ARE (4) WS42 OR (2) WS84 OR LESS AND THE JUMP DOES NOT EXCEED (8) WS42 OR (4) WS84 9. REFER TO 4A-5.1 FOR TYPICAL WORKSTATION POWER LAYOUT 10. ALL DEVICES FOR DEDICATED CIRCUITS SHALL BE GRAY 11. OUTLETS SHOWN FOR LOCATION ONLY. FINAL DESIGN BY ELECTRICAL SUBCONTRACTOR. SHEET NOTES lO CONTRACTOR TO VERIFY THE COPIER SPECIFICATIONS WITH THE CLIENT PRIOR TO INSTALLATION. PROVIDE AND INSTALL THE APPROPRIATE POWER & COMMUNICATION REQUIREMENTS. O GC TO CONVERT EXISTING DUPLEX OUTLET TO FURNITURE POWER FEED. O GC TO CONVERT EXISTING TELE/DATA OUTLET TO FURNITURE COMMUNICATION FEED. CONTRACIOR TO CONFIRM THAT EXISTING CONDUIT IS THE APPROPRIATE SIZE, COORDINATE WITH TENANT TELE/ DATA CONTRACTOR. INDIANA INSURANCE 350 EAST 96TH STREET INDIANAPOLIS, IN. FIRST FLOOR 2 ISSUE FOR PERMIT 06/14/04 1 ISSUE FOR PRICING 06/11/04 Issue Description Date IA ® H E Drawn: DM Check KSY No: 54132.00 POWER & Owner Scale: AS NOTED COMMUNICATION Title: PLAN Sheet: ■ REFLECTED CEILING PLAN 1/8-_1'_0 _1"-0 REFLECTED CEILING PLAN NOTES I I REFLECTED CEILING PLAN LEGEND I GENERAL NOTES I SHEET NOTES � 1. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECT'S DRAWINGS. 2. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITIES AND PAINTED TO MATCH CEILING FINISH. 3. FURNISH AND INSTALL ALL FIXTURES, ASSOCIATED TRIM, FIXTURE LAMPS, AND SEISMIC BRACING AS REQUIRED TO MATCH EXISTING. 4. LIGHT FIXTURES, EXIT SIGNS, SPRINKLERS AND OTHER CEILING ELEMENTS SHALL BE LOCATED IN CENTER OF INDIVIDUAL CEILING TILE U.O.N. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT CEILING FINISH U.O.N.. 6. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 48" ABOVE FINISHED FLOOR TO CENTER OF SWITCH U.O.N.. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GANGED TOGETHER AND FINISHED WITH ONE COVER PLATE U.O.N.. 7. ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP OF FINISHED FLOOR TO BOTTOM OF FINISHED GYPBOARD OR CEILING TILE AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. 8. THE REFLECTED CEILING PLAN INDICATES THE LOCATION OF CEILING HEIGHTS, LIGHT TYPES, LIGHT FIXTURES, SWITCH LOCATIONS, AND ASSOCIATED ITEMS. 9. G.C. TO REPAIR, REVISE, CLEAN AND OR REPLACE EXISTING CEILING GRID SYSTEM AND TILES TO ACHIEVE DOCUMENTED DESIGN AND A CONSISTENT STYLE AND AS -NEW APPEARANCE. 10. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE -CEILING DEMO'D 2'X4' FLUORESCENT LIGHT FIXTURE ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS. 11. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, 0 EXISTING 2'X4' FLUORESCENT LIGHT FIXTURE DUCTS, STRUCTURES, HVAC, AND/OR (E)CONDUIT, PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEEN ARCHITECT'S CEILING GRID LOCATION & ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. REUSED/RELOCATED 2'X4' FLUORESCENT LIGHT FIXTURE 12. SUBMIT GRILLE, SPRINKLER, THERMOSTAT, AND OTHER FIXTURE AND ELEMENT LAYOUTS TO THE ARCHITECT FOR REVIEW AT LEAST 2 WEEKS PRIOR TO INSTALLATION. EXISTING 2'X2' CEILING GRID & TILE TO REMAIN. 13. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ANY AND ALL OTHER APPLICABLE ITEMS; INSTALL APPLICABLE NEW PLUMBING, MECHANICAL FANS, DUCTS, CONDUITS, AND OTHER F.0_LG .@ RELATED AND APPURTENANT ITEMS SO AS TO NOT CONFLICT WITH LUMINAIRES AND EXISTING CEILING HEIGHT LABEL. ANY AND ALL FIELD CONDITIONS. E ® EXISTING CEILING MOUNTED EXIT SIGN TO REMAIN. 14. FURNISH AND INSTALL UNDERWRITERS LABORATORIES INC. (UL) LABELED DEVICES ® NEW CEILING MOUNTED EXIT SIGN TO EXISTING. THROUGHOUT. DEMO'D CEILING MOUNTED EXIT SIGN. 15. INSTALL LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER, LENS, BAFFLE, AND THE LIKE, TO AVOID FIXTURE SOILING OR DAMAGE; FIXTURES SHALL BE -6'4- E EXISTING WALL MOUNTED LIGHT SWITCH TO REMAIN. MAINTAINED CLEAN AND AS NEW; LAMPS SHALL BE NEW AT PROJECT COMPLETION. -04- NEW WALL MOUNTED LIGHT SWITCHING LOCATION 1, EXISTING CEILING GRID TO REMAIN. REUSE/RELOCATE EXISTING LIGHT FIXTURES. 2. EXISTING CEILING MOUNTED EXIT SIGNS TO REMAIN. 3. PROVIDE NEW 2' X 4' EMERGENCY LIGHTING AS REQUIRED TO COMPLY WITH LOCAL BUILDING CODES. 4. CONTRACTOR TO VERIFY IN FIELD QUANTITY OF EXISTING 2'X4' LIGHT FIXTURES FOR REUSE. CONTRACTOR TO PROVIDE NEW TO MATCH EXISTING IF QUANTITY AVAILABLE DOES NOT MEET REFLECTED CEILING PLAN REQUIREMENTS. 5. CONTRACTOR TO REPLACE ANY DAMAGED, BROKEN, STAINED, OR DIRTY CEILING TILES (TO MATCH EXISTING). O CONTRACTOR TO PATCH AND REPAIR GRID AS NECESSARY AT AREAS OF DEMOLITION. Liberty,Mutua.. INDIANA INSURANCE 350 EAST 96TH STREET INDIANAPOLIS, IN. FIRST FLOOR 2 ISSUE FOR PERMIT 06/14/04 1 ISSUE FOR PRICING 06/11/04 Issue Description Date 10 Drawn: DM Check: KSY No: 54132.00 Owner Scale: AS NOTED REFLECTED CEILING Title PLAN 'HP"f. FINISH PLAN NOTES 1. NO PAINTING OR INTERIOR FINISHING SHALL BE DONE UNDER CONDITIONS WHICH WILL JEOPARDIZE THE QUALITY OR APPEARANCE OF SUCH WORK. ALL WORKMANSHIP WHICH IS JUDGED LESS THAN FIRST QUALITY BY THE ARCHITECT WILL BE REJECTED. 2 ALL DOOR FRAMES AND WOOD WINDOW SILLS SHALL BE PAINTED SEMI -GLOSS FINISH. U.N.O. 3. ALL SURFACES SHALL BE PREPARED TO RECEIVE THE SPECIFIED FINISH. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH AND PREPARED TO RECEIVE THE SPECIFIED FINISH. PAINT GRADE WOODWORK SHALL BE HAND SANDPAPERED BETWEEN COATS AND DUSTED CLEAN. ALL HOLES, PITCH POCKETS OR SAPPY PORTIONS SHALL BE SCRAPED AND SHELLACKED, OR SEALED WITH KNOT SEALER. NAIL HOLES, CRACKS OR DEFECTS SHALL BE PUTTIED AFTER FIRST COAT, WITH PUTTY MATCHING COLOR OF STAIN OR PAINT FINISH. REMOVE OIL OR GREASE WITH MINERAL SPIRITS. 4. ALL CRACKS, HOLES, IMPERFECTIONS IN EXISTING WALLS, PARTITIONS OR GYPBOARD SHALL BE FILLED WITH PATCHING PLASTER AND SMOOTHED OFF TO MATCH ADJOINING SURFACES. 5. INTERIOR GYPSUM BOARD SURFACES SHALL BE WIPED WITH A DAMP CLOTH JUST PRIOR TO APPLICATION OF THE FIRST COAT, IN ORDER TO LAY FLAT ANY NAP WHICH MAY HAVE FORMED IN SANDING PROCESS. 6. UPON COMPLETION REMOVE ALL PAINT FROM WHERE IT HAS SPILLED, SPLASHED, SPLATTERED OR SPECKLED ON EXPOSED ADJACENT SURFACES. 7 NOT USED 8. EXAMINE ALL FINISH SURFACES AFTER COMPLETION OF WORK INCLUDING WOOD FLOORING AND MILLWORK INSTALLATION AND PROCEED WITH "TOUCH-UP" AS REQUIRED. 9. PROVIDE ARCHITECT WITH A MINIMUM OF (3) 8" X 10" BRUSH -OUTS OF EACH COLOR & FINISH FOR ARCHITECT'S APPROVAL AT LEAST 2 WEEKS PRIOR TO SITE APPLICATION. ON-SITE APPLICATION WILL BE REQUIRED ONE WEEK PRIOR TO FINAL APPROVAL. ARCHITECT RESERVES THE RIGHT TO ADJUST ANY COLOR/FINISH ONCE THE WALL TEST HAS BEEN MADE. 10. UNDERSIDE OF SOFFITS (WHERE OCCURS) TO RECEIVE A FINISH TO MATCH ADJACENT VERTICAL FINISH, U.O.N. 11. ELECTRICAL SWITCH AND OUTLET COVER PLATES, SURFACE HARDWARE, ETC. SHALL BE INSTALLED AFTER PAINTING AND/OR APPLICATION OF WALLCOVERINGS & CARPET SPECIFIED. 12. PRIOR TO SITE APPLICATION, PROVIDE ARCHITECT WITH 8" X 10" SAMPLE CUTTINGS FROM ACTUAL DYE LOTS OF ALL SPECIFIED WALLCOVERINGS, PLASTIC LAMINATES, WALL BASE, AND RESILIENT FLOORING FOR ARCHITECT'S APPROVAL AND PROVIDE EXPECTED DELIVERY DATE TO JOB SITE. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ALLOWING FOR DELIVERY LEAD TIMES FOR ALL FABRICS AND OTHER CUSTOM FINISHES WITHIN THE CONSTRUCTION SCHEDULE. ALL DELIVERY TIMES MUST BE CONFIRMED, AND ANY EXCESSIVE LEAD TIME MUST BE BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY TO ALLOW FOR RE -SPECIFICATION IF NECESSARY. 14. MODIFY EXISTING FLOOR SURFACES AS REQUIRED TO INSTALL NEW FLOORING MATERIALS, THUS PREVENTING NOTICEABLE LUMPS OR DEPRESSIONS. 15. ALL AREAS, EXCEPT AS SPECIFICALLY NOTED, SHALL RECEIVE CARPET. 16. ALL PARTITIONS, COLUMNS, AND MILLWORK TO RECEIVE STRAIGHT RESILIENT BASE AT CARPET, COVE RESILIENT BASE AT RESILIENT FLOORING, U.O.N. 17. SEE FINISH PLAN, ELEVATIONS AND DETAILS FOR CLARIFICATION OF EXTENT OF FINISH MATERIALS. 18. PAINT CEILING ACCESS PANELS WHERE THEY OCCUR TO MATCH ADJACENT CEILING FINISH. 19. STAINED AND PAINTED SURFACES SHALL BE FINISHED SUCH THAT JOINTS ARE NOT VISIBLE WHEN VIEWED FROM ANY REASONABLE ANGLE. 20. ALL INTERSECTIONS OF FLOOR FINISH MATERIALS SHALL BE LOCATED DIRECTLY UNDER CENTER OF DOOR, WHERE OCCURS, U.O.N. 21. SUBMIT CARPET SEAMING PLAN TO ARCHITECT PRIOR TO ORDERING AND AT LEAST (4) WEEKS PRIOR TO INSTALLATION FOR ARCHITECT'S REVIEW AND APPROVAL. 22. PAINT ALL ELECTRICAL PANELS TO MATCH ADJACENT WALLS. THIS FINISH TO BE SEMI -GLOSS. SEE SPECIFICATIONS SHEET AN4 23. ALL WALLS TO BE PAINTED U.O.N. SEE FINISH SCHEDULE. 24, PROVIDE TRANSITION STRIP IN AREAS WHERE FLOOR FINISH CHANGES OCCUR. COORDINATE COLOR WITH ARCHITECT. 25. PAINTING CONTRACTOR TO VERIFY ALL FINISHES FOR PROPER PRIMER APPLICATIONS. FINISH SCHEDULE WALL FLOOR TYPICAL PAINT COLOR I TO MATCH EXISTING Bc TYPICAL CARPET- TBD VCT VCT MANUFACTURER: ARMSTRONG STYLE NAME: STANDARD EXCELON IMPERIAL TEXTURE COLOR NAME & No.: #51810 WASHED LINEN NOTE: VCT -1 PROVIDED AND INSTALLED BY GENERAL CONTRACTOR BASE eVINYL BASE TO MATCH EXISTING 4" HIGH, 1/8" VINYL NOTE: STRAIGHT BASE AT CARPET, COVE BASE AT VCT. Liberty,mutua.. INDIANA INSURANCE 350 EAST 96TH STREET INDIANAPOLIS, IN. FIRST FLOOR ,li_).FWlNlSH PLAN 7/8"=1'-0" 2 ISSUE FOR PERMIT 06/14/04 1 ISSUE FOR PRICING 06/11/04 FINISH LEGEND GENERAL NOTES Issue Description Date BASE FINISH DESIGNATION B FINISH NUMBER l 1. EXISTING FLOORING TO REMAIN, U.O.N. FLOOR FINISH DESIGNATION e 2. ALL BASE SHALL BE STRAIGHT BASE EXCEPT WHERE OCCURS AT VCT, BASE FINISH NUMBER AT VCT SHALL BE COVE BASE WALL FINISH DESIGNATIONP FINISH NUMBER � 3. ALL DOOR FRAMES TO MATCH EXISTING, U.O.N; REFER TO AN -3.0 MILLWORK FINISH DESIGNATION Mw 4. ALL DOORS SHALL BE AS PER BUILDING STANDARD. IA FINISH NUMBER 1 ANNOTATION TYPES B ; P P _ 2 SHEET NOTES C1 0 C2— FIN I SH MATERIAL -SEE FINISH SCHEDULE O NEW CARPET IN THIS AREA. APPLY CARPET OVER EXISTING VCT. O2 EXISTING VCT TO REMAIN IN THIS AREA. O3 CONTRACTOR TO PATCH AND REPAIR BUILDING FINISHES AS REQUIRED BY PROJECT DEMOLITION AND CONSTRUCTION. MATCH EXISTING Drawn: DNI Check: KSY Owner Approv FINISHES. al : ® CONTRACTOR TO PATCH AND REPAIR CARPET AS REQUIRED BY PROJECT DEMOLITION. CONTACT THE BUILDING OWNER FOR FINISH Job No: 54132".00 Scale: AS NOTED SPECIFICATIONS. FINISH T.+ PLAN Sheet: FURNITURE PLAN 1/8"=l —0 *FOR REFERENCE ONLY* EQUIPMENT LEGEND FURNITURE ANNOTATION TYPES GENERAL NOTES I SHEET NOTES 0 FAX MACHINE, BY TENANTWIDTH 1. REFER ALSO TO FURNITURE PANEL PLAN, 4A-5.1, FOR ADDITIONAL INFORMATION © PRINTER, BY TENANT NUMBER OF DRAWERS © COPIER, BY TENANT FILE CABINET A402 WORKSTATION NUMBER Liberty Mutual..,. INDIANA INSURANCE 350 EAST 96TH STREET INDIANAPOLIS, IN. FIRST FLOOR z 2 ISSUE FOR PERMIT 06/14/04 1 ISSUE FOR PRICING 06/11/04 Issue Description Date HE T— Drawn: DNI Check: KSY Owner No: 54132.00 Scale AS NOTED FURNITURE Title: PLAN Sheet: FURNITURE PANEL PLAN 1/811 -11 - TOR REFERENCE ONLY' TYPICAL 42 WORKSTATION GENERAL NOTES POWER CONFIGURATION U.O.N. 1. REFER ALSO TO FURNITURE PLAN, 4A-5.0, FOR ADDITIONAL INFORMATION 6' 3" Ln 68/36 68/36 * OR 68, REFER TO PLAN TYPICAL CARREL POWER CONFIGURATION U.O.N. 68/36 0 0 Ln Ln * OR 68, REFER TO PLAN SHEET NOTES qo Liberty, Mutual.,,. INDIANA INSURANCE 350 EAST 96TH STREET INDIANAPOLIS, IN. FIRST FLOOR a lk 2 ISSUE FOR PERMIT 06/14/04 1 ISSUE FOR PRICING 06/11/04 Issue Description Date Drawn: DM Check: KSY Owner ,Job Na 5413200 Scale: AS NOTED FURNITURE Title: PANEL PLAN Sheet: ■ 2 1/2" 25 GA. METAL STUD TOP RUNNER ANCHOR TO SL NOTE: CONSTRUCTION CONDITIONS VARY UNDERSIDE OF STRUCTURAL UNDERSIDE OF STRUC L DEPENDING ON PARTITION TYPE AT THIS INTERSECTION SLAB /DECK SLAB DECK PLEASE REFER TO MAIN CROSS TEES �> 2 1/2 25 GA TAL STUD SUPPORTA " O.C.AS CONSTRUCTION PLAN ) SEISMIC BRACING OR BRACING REQUIREDLibe rty 2 1/2" GA. METAL STUD BR T 48" O.C.. SCHEDULED/EXISTING CEILING SEE REFLECTED CEILING PLAN .� mutu FOR SPECIFICATIONS f CROSS TEES 4" 4' — — — — — — — MAIN CROSS TEES r 77771 hiiiii 11'-O" VIF 3l 2 1/2" 25 GA, METAL STUD 3 5/8" 25 GA. CONTINUOUS - --- RUNNER TIED TO MAIN CROSS TEE 3 5/8" 25 GA. CONTINUOUS 8'-x" METAL STUD TOP RUNNER SCHEDULED CEILING INDIANA INSURANCE _ SEE REFLECTED CEILING PLAN 5/8" GYPSUM BOARD TYPE X FOR SPECIFICATIONS ON BOTH SIDE. 350 EAST 96TH STREET 3" ACOUSTICAL BATT INSULATION. ALUM OR NEW TO INDIANAPOLIS IN. MATCHFEXISTINGEUSED o 3 5 8" 25 GA. METAL STUDS / 1 @ 16" O.C. 0. C. 2"x1/2" CONTINUOUS METAL STOP AS PEXSTG SCHEDULED BASE FIRST FLOOR w S ULED TEMPERED GLASS SCHEDULED FLOOR PAINT GRA IRE TREATED NOTE: WOOD BLOCK REFER TO CONSTRUCTION PLAN FOR EXACT DOOR JAMB LOCATIONS. SEALANT DOUBLE 2 1/2" STUDS AT JAMBS (TYPICAL). 3 5/8" 25 GA. CONTINUOUS°, FLOOR METAL STUD RUNNERop ry 17 13 HEAD DETAIL ® SIDELITE 3" = 1'- 5 JAMB DETAIL 3" = 1'-0" 1 PARTITION TYPE "A" ACOUSTICAL PARTITION pp Oft _ 'E�E R I IJ IOF i SEALANT -- - Lr` I' 1; - MFT, EP i, E 12'-10" VIFHIT % - - - - - 1,/F T'� TUT UF - _ - UNDERSIDE OF STRUCTURAL' - - "- SLAB/DECK / _ 2 1/2" 25 GA. CONTINUOUS /I -E F)_ I_ �1'il METAL STUD TOP RUNNER �IL'vI r 5/8" GYPSUM BOARD TYPE X 1 - L"� ,�F�_'� , 'EE - 1 - - -- - - ON BOTH SIDES TO UNDERSIDE OF STRUCTURE 77111 11 1111111111111111 SCHEDULED/EXISTING CEILING - - - F r r = SEE REFLECTED CEILING PLAN � J F -I'!, E - FOR SPECIFICATIONS 'IFI--- _ E �_I IT 8'-8" VIF i-E 3" ACOUSTICAL BATT INSULATION. I 2 1/2" 25 GA. METAL STUDS SLAB TO SLAB @ 16" O.C. _ F'T I - �JEl ,� �.9FT'L E f?E I I � Iv`I I�E — — — �' x i � I f I1J'.II SCHEDULED BASE SCHEDULED FLOOR -, �IEI�_TNC H L i �L SEALANT F 2 1/2" 25 GA. CONTINUOUS METAL STUD FLOOR RUNNER 18 - 14 10 TYPIC ON FULL HEIGHT DOOR IN ACOUSTICAL 3" = 1'-0" TYPICAL NON FULL HEIGHT GLASS SIDELITE 3' = 1'- 2 PARTITION TYPE "B" ACOUSTICAL PARTITION 3" = 1'-0" IONAL FIRE RATED SEALANT 12'-10" VIF 'K UNDERSIDE OF CTURAL - IF- SLAB/DECK ICE -. 2 1/2" GA. CONTINUOUS / MET TUD TOP RUNNER - -L AYER OF 5/8" GYPSUM BOARD -H I F YPE X ON BOTH SIDES TO UNDERSIDE _ - — — — — itt OF STRUCTURE SCHEDULED/EXISTING CEILING § SEE REFLECTED CEILING PLAN !L- ° �_�-� FOR SPECIFICATIONS 8'-8" VIF GENERAL OFFICE AREA INTERIOR OF OFFICE ACOUSTICAL BATT INSULATION. SCHEDULED TEMPERED GLASS 1 2' X 1 2" REMOVABLE op 2 1/2" 25 GA. METAL STUDS METAL STOPS SLAB TO SLAB @ 16" O.C. ALUM FRAME, REUSED OR NEW TO!-''\I MATCH EXISTING \i -` 'L-;%:F = SCHEDULED BASE WOOD SHIM _ Z�-- CHEDULED FLOOR 2 ISSUE FOR PERMIT 06/14/04 SCHEDULED FLOOR F-�_ — — - — — 1 ISSUE FOR PRICING 06/11/04 FIRE RA EALANT Issue Description Date 2 1/2" 25 GA, NTINUOUS PARTITIONS COMPLY METAL STUD FLO UNNER WITH UL N #U419 (ANSI/ 63) 19 - 15 11 SILL DETAIL ® SIDELITE 3" = 1'-0' TYPICAN NON FULL HEIGHT DOOR 3" = 1�_ PARTITION TYPE "C" - ONE HOUR RATED 3"= 1'- ACOL CAL PART TION T VIF UNDERSIDE OF UCTURAL DECK T Fi= -- Fig F,--F 3'-0" DOOR MAIN CR TEE - - -._ _ SIDE LITE SEIS RACING OR BRACING A QUIRED - - - - EDULED CEILING, SEE - - 1F -1-1 REFLECTED CEILING PLAN � - - - FOR SPECIFICATIONS -- u 2S Hk 0„ SEALANT 2 1/2" 25 GA. CONTINUOUS _ - METAL STUD TOP RUNNER Drawn DM Check: KSY Owner Approval: SCHEDULED DOOR 5/8" GYP WB @ ONE SIDE ONLY - 1/4" CLEAR, TEMPERED GLASS2 1/2", 25 GA. METAL STUDS SLAB lob No: 54132.00 Scale. AS NOTED TO UNDERSIDE OF CEILING @ 16" O.C. ALUM FRAME, REUSED OR NEW TO HEDULED BASE MATCH EXISTING � SC LED FINISHED FLOOR Z— DETAILS FC� i �A�� L"— V - AND SEALANT 2 1/2" 25 GA. INUOUS METAL STUD I NER S ECTI O N S Title: T/ SLAB 20 _ 16 PARTITION AT FIRE EXTINGUISHER CABINET 8 JAMB DETAIL ® SIDELITE TYPICAL FURRED OUT PARTITION 3" = 11- Shee ■