HomeMy WebLinkAboutTPS005.C2.0.Bldg. Addition Site PlanC.O. TYPE IINV=752.015' 15' 22.8' 11.0' F.F.E. = 755.70 (NAVD 88 DATUM) Community Drive94± LF 6-INCH SDR 35 PVC ASTM-D 3034 LATERAL @ 1.04% WITH 12ga TRACER WIRE REMOVE/REPLACE EXISTING PLAY GROUND FENCINGEXISTING C.O. T.C. = 752.2± INV. = 745.45 INSTALL NEW 6" WYE FITTING SDR 26 PVC INV. = 747± (VERIFY EXISTING INVERT PRIOR TO CONSTRUCTING LATERAL) REFER TO ARCHITECTURAL PLANS FOR BLDG. DIMENSIONS EXISTING PLAYGROUND FENCE D D D D EXISTING SANITARY LATERAL14 5 NEW BUILDING ADDITION 2500 G.S.F. EXISTING SCHOOL BUILDING EXISTING PLAYGROUND F EX. SAN. LATERALRF EXISTING SCHOOL BUILDING F.F.E. = 755.70 D F 9.4' 11.5' A/C A/C61.83'39.25' AEXISTING 12" PVC ROOF DRAIN PIPEEXISTING 12" RCP EXISTING C.O. INV. = 749.7± RFRF RF RF RFEXISTING GAS MAINEX. 8" SCH40 PVC EX. 6" SCH40 PVC 18 " OF VERTICAL SEPARATION MUST BE MAINTAINED FOR ALL UTILITY CROSSINGS. PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC. GROUP, INC.PROF E SS ION A L E NG INEERIND IA NA PE10910647 STATE OF -o NREG I S TER E DBR IA N S CR O SSTPS.005 C2.0NOBLESVILLE, INDIANA 4606015575 STONY CREEK WAYTHE PLAY SCHOOL at LEGACY, INC.SITE & UTILITY PLANPLAY SCHOOL at LEGACY - CLASSROOM ADDITION14454 COMMUNITY DRIVECARMEL, INDIANA 4603302/16/2018 LEGEND: CONTRACTOR NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 DEVELOPMENT SUMMARY PROPOSED BUILDING ADDITION = 2,500 G.S.F.± TOTAL SITE AREA = 2.0 AC+/- CURRENT ZONING = PUD GREENSPACE AREA = 59% (51,555 / 87,345) TOTAL DISTURBED AREA = 10,590 SF ± = 0.24 Ac +/- ANTICIPATED CONSTRUCTION START/COMPLETION DATE MAY, 2018 / JUNE, 2019 TOTAL PARKING SPACES = 60 (INCLUDES STREET SPACES) TOTAL PARKING SPACES REQ'D = 59 (1 SPACE/EMPLOYEE + 1 SPACE/6 STUDENTS) TOPOGRAPHIC & BOUNDARY NOTE PLAN NOTES: D BUILDING NOTE REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. F SITE LAYOUT NOTES REVISION RECORD DEPENDING ON THE CONSTRUCTION SEASON, MOISTURE CONTENT AND PROPERTIES OF THE SOILS ON SITE, CHEMICAL MODIFICATIONS AND/OR LIME STABILIZATION MAY BE REQUIRED. SEE SHEET C9.0 FOR SPECIFICATIONS. UTILITY LOCATE NOTE UTILITY NOTES 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING AGENCY SHALL APPLY FOR ALL SANITARY SEWERS, STORM SEWERS, AND WATER MAINS. 3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 4. ALL WATER SERVICE / FIRE LINES ARE REQUIRED TO HAVE A 60" MINIMUM COVER OVER TOP OF PIPE. ALL WATER/SANITARY LINE CROSSINGS MUST MAINTAIN 18" VERTICAL SEPARATION BETWEEN OUTSIDE OF PIPES PER INDIANA STATE DEPARTMENT OF HEALTH. 5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH REQUIREMENTS. (APPLIES TO COMMERCIAL ONLY) 6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND CONDUIT PER UTILITY COMPANY'S SPECIFICATIONS. 7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS AFFECTED DURING CONSTRUCTION. REFER TO THE CITY OF LAWRENCE DPW - STANDARDS FOR RESTORATION REQ'S. 8. CONTRACTOR TO LOCATE ALL EXISTING UTLITIES AT ANY PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED. PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL SEPARATION LESS THAN 18 INCHES. CATV: Brighthouse Networks Jason Kirkman (317) 632-9077 x291 jason.kirkman@mybrighthouse.com Telephone: AT&T Steve Krebs (317) 252-4275 SK4986@att.com Fire Service: Office of Fire Chief, Fire Station #1 Gary Hoyt Two Civic Square Carmel, IN 46032 (317) 571-2600 cellison@carmel.in.gov UTILITY CONTACTS ISDH NOTES THE WATER-LINES THROUGHOUT THE PROJECT SHALL BE INSTALLED WITH AT LEAST 54-INCHES OF COVER TO PROVIDE PROTECTION FROM FREEZING. WHERE WATER-LINES AND SEWERS (STORM AND/OR SANITARY) CROSS AND THE WATER-LINE CANNOT BE PLACED ABOVE/BELOW THE SEWER WITH A MINIMUM OF 18-INCHES VERTICAL CLEARANCE, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE DUCTILE IRON PIPE WITH MECHANICAL JOINTS WITHIN 10 FEET OF THE WATER-LINE. SANITARY SEWERS SHOULD HAVE A MINIMUM OF 2 FEET OF COVER. Natural Gas: Vectren Energy Joanie Clark (317) 776-5532 jlclark@Vectren.com Wastewater & Water: Carmel City Utilities John Duffy 760 Third Avenue SW Carmel, IN 46032 (317) 632-9077 Drainage: Carmel Engineering Gary Duncan or John Thomas 1 Civic Square Carmel, IN 46032 (317) 571-2441 gduncan@carmel.in.gov Streets: Carmel Street Department Dave Klingensmith 3400 West 131st Street Westfield, IN 46074 (317) 733-2001 Electric: Duke Energy Shirley Hunter 16475 Southpark Dr. Westfield, IN 46074 (317) 896-6721 shirley.hunter@duke-energy.com RF A 05/23/18