HomeMy WebLinkAboutA501 Exterior Elevations1. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL STEEL AND MASONRY SIZES, SPACING AND REINFORCING 2. ALL EXTERIOR WOOD BLOCKING TO BE MOISTURE RESISTANT PRESSURE PRESERVATION TREATED (PPT) PER AWPA PER OBC SECTION 2303.1.8. 3. ALL FASTENERS, CONNECTORS OR OTHER HARDWARE IN DIRECT CONTACT WITH PRESSURE PRESERVATION TREATED WOOD OR FIRE-RETARDANT TREATED WOOD SHALL BE STAINLESS STEEL TYPE 304 OR TYPE 316, OR HOT DIPPED GALVANIZED STEEL ASTM653, CLASS G-185 WITH 1.85 OUNCES OF ZINC PER SQUARE FOOT TO REDUCE THE CORROSION PROCESS. 4. ALL EXPOSED ARCHITECTURAL STONE, STRUCTURAL MASONRY VENEER AND CMU SHALL RECEIVE SPRAY-APPLIED WATER REPELLENT, REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. 5. ALL THRU WALL UTILITY PENETRATIONS (PIPE, CONDUIT, ETC) AT CMU WALL CONSTRUCTION ARE TO BE SEAL FULL PERIMETER (BOTH INTERIOR AND EXTERIOR SIDE) WITH SEALANT OVER BACKER MATERIAL. 6. LAP ALL THRU-WALL FLASHINGS IN A WATER SHEDDING FASHION. TAPE ALL EXPOSED EDGES. 7. ALL MISCELLANEOUS PREFFINISHED METAL COPINGS AND FLASHING SHALL BE 24 GAUGE, MINIMUM. HAVE HEMMED EDGES, AND HAVE CONTINUOUS SEALANT BENEATH EDGES AND SEAMS. 8. PROVIDE CONTINUOUS ANCHORAGE FOR ALL THRU-WALL FLASHING. 9. REFER TO MANUFACTURER'S SPECIFICATIONS FOR SPECIFIC MASONRY, MOISTURE BARRIER, AND INSTALLATION REQUIREMENTS. ALL REQUIREMENTS MUST BE MET. FAILURE TO FOLLOW SPECIFIC CRITERIA WILL RESULT IN REMOVAL OF ALL UNACCEPTABLE CONSTRUCTION. 10. EPDM SINGLE-PLY MEMBRANE ROOFING SHALL BE MECHANICALLY FASTENED ON ALL HORIZONTAL SURFACES AND FULLY ADHERED ON ALL VERTICAL SURFACES WITHIN MECHNICAL WELL. 11. ALL SHEATHING THAT IS TO RECEIVE ROOF MEMBRANE IS TO BE ATTACHED TO FRAMING BY THE USE OF NON-REVERSING SCREWS. NO NAIL FASTENERS ARE PERMITTED. GENERAL NOTES - EXTERIOR ELEVATIONS 12. PROVIDE 1/2" BACKER ROD AND SEALANT AT ALL DISSIMILAR MATERIALS. 13. ALL THERMAL BATT INSULATIONTO BE FOIL-FAC (FSK-25) TYPE AS SCHEDULED. ALL SEAMS IN FOIL FACED BATT INSULATION TO BE RATED TO ENSURE CONTINUITY OF VAPOR BARRIER. 14. PROVIDE ICE & WATER SHIELD PROTECTION AT ALL ROOF SLOPES LESS THAN 4:12 PITCH 15. ALL EXTERIOR DOOR AND WINDOW JAMBS TO BE INFILLED WITH FOAM AND SEALANT FULL PERIMETER. 16. WRAP WEATHER RESISTANT BARRIER FULL DEPTH OF ALL WINDOW AND DOOR ROUGH OPENINGS PER MANUFACTURERS SPECIFICATIONS. 17. PER NFPA (2010 EDITION) SECTION 8.15.1.2 CONCEALED SPACES NOT REQUIRING SPRINKLER PROTECTION. a. SECTION 8.15.1.2.1, CONCEALED SPACES OF NONCOMBUSTIBLE AND LIMITED-COMBUSTIBLE CONSTRUCTION WITH MINIMAL CONBUSTIBLE LOADING HAVING NO ACCESS SHALL NOT REQUIRE SPRINKLER PROTECTION. THE SPACES SHALL BE CONSIDERED A CONCEALED SPACES EVEN WITH SMALL OPENINGS SUCH AS THOSE USED AS RETURN AIR FOR PLENUM. b. SECTION 8.15.1.2.2, CONCEALED SPACES OF NONCOMBUSTIBLE AND LIMITED COMBUSTIBLE CONSTRUCTION WITH LIMITED ACCESS AND NOT PERMITTING OCCUPANCY OR STORAGE OF COMBUSTIBLES SHALL NOT REQUIRE SPRINKLER PROTECTION. THE SPACES SHALL BE CONSIDERED A CONCEALED SPACE EVEN WITH SMALL OPENINGS SUCH AS THOSE USED AS RETURN AIR FOR PLENUM. c. SECTION 8.15.2.3, CONCEALED SPACES FORMED BY STUDS OR JOISTS WITH LESS THAN 6 INCHES BETWEEN THE INSIDE OF NEAR EDGES OF THE STUDS OR JOISTS SHALL NOT REQUIRE SPRINKLER PROTECTION. d. SECTION 8.15.1.2.5, CONCEALED SPACES FORMED BY CEILING ATTACHED DIRECTLY TO OR WITHIN 6 INCHES OF WOOD JOIST CONSTRUCTION AND FIRE BLOCKED INTO AREAS NOT EXCEEDING 160 CUBIC FEET SHALL NOT REQUIRE SPRINKLER PROTECTION. e. SECTION 8.15.1.2.11, CONCEALED SPACES IN WHICH THE EXPOSED MATERIALS ARE CONSTRUCTIONED ENTIRELY OF FIRE-RETARDANT TREATED WOOD AS DEFINED BY NFPA703, STANDARD FOR FIRE-RETARDANT TREATED WOOD AND FIRE-RETARDANT COATINGS FOR BUILDING MATERIALS, SHALL NOT REQUIRE SPRINKLER PROTECTION. EXISTING EIFS VENEER TO REMAIN, PAINT AS NOTED, COORDINATE WITH OWNERS REPRESENTATIVE IN FIELD. EXISTING MASONRY VENEER TO REMAIN. EXISTING LIGHTING FIXTURES TO REMAIN. BLADE SIGN PROVIDED BY AND INSTALLED BY TENANTS SIGNAGE CONTRACTOR. G.C. TO COORDINATE INSTALLATION IN FIELD (SEE ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS). NEW SURFACE MOUNTED SIGNAGE PROVIDED BY AND INSTALLED BY TENANTS SIGNAGE CONTRACTOR. G.C. TO COORDINATE INSTALLED IN FIELD. NEW CANOPY WITH ROLL-DOWN CURTAIN SYSTEM, 1X6 IPE PLANKS, HARDIE PANEL CANOPY ABOVE (SW7020, 'BLACK FOX') (SEE A1.01, A1.03 AND A/A7.01 FOR ADDITIONAL INFORMAITON). EXISTING CANOPY TO REMAIN. ADD STEEL CHANNEL TO FACE AND PAINT INSIDE FACE OF FLANGE PT-3 (SEE A3.02). NEW BRACKET TO BE MOUNTED TO EXTERIOR FACE OF EXISTING CANOPY, COORDINATE WITH OWNER. MOUNT MARQUEE LIGHTS AND VALENCE UNDER CANOPY (SEE A7.01 FOR ADDITIONAL DETAILS). FABRIC VALENCE, PROVIDED BY AND INSTALLED BY TENANT'S AWNING CONTRACTOR. G.C. TO PROVIDE AND INSTALL FRT BLOCKING AS REQUIRED AND TO COORDINATE INSTALLATION IN FIELD. EXTERIOR ELEVATIONS - CODED NOTES REMOVE EXISTING FINISH BEHIND EXISTING AWNING, INSTALL 1X6 IPE PLANS. FIELD VERIFY, COORDINATE WITH OWNER. REMOVE EXISTING CULTURED STONE BASE, TO BE REPLACED WITH 1X6 IPE PLANKS. SEE E/7.02 FOR ADDITIONAL INFORMATION. NEW BLACK PANEL AWNINGS, COORDINATE WITH AWNING CONTRACTOR (SEE A7.02 FOR ADDITIONAL DETAILS.) ROLL-DOWN CURTAIN SYSTEM PROVIDED BY AND INSTALLED BY TENAN'TS AWNING CONTRACTOR. GC TO COORDINATE. MARQUEE LIGHTING INSTALLED DIRECTLY TO BOTTOM FACE OF STEEL BEAM (SEE A0.04 FOR DETAILS AND ELECTRICAL DRAWINGS). TUBELITE T 14000 SERIES STOREFRONT SYSTEM WITH GLAZING (SEE A8.02 FOR ADDITIONAL INFORMATION) STEEL COLUMNS PAINTED PT-1, COORDINATE WITH STRUCTURAL. REMOVE EXISTING SCONCE. PATCH AND PAINT AS REQUIRED 36" HIGH 2X4 STEEL TUBE RAIL, PAINTED PT-1 ATTACHED TO STEEL COLUMNS. PROVIDE 1/8" METAL CABLE AT 4" O.C. BELOW. EXISTING STOREFRONT TO REMAIN. EXISTING STEEL TIE BACKS TO REMAIN, PAINT PT-1 EXISTING STEEL TIE BACKS TO REMAIN, PAINT PT-1 01 02 03 04 05 06 07 08 10 11 12 13 09 14 15 16 17 18 19 20 2 A A7.01 PIES AND PINTS 04 01 02 05PT-07 PT-08 PT-08.06 07 07 PT-01 PT-01 05 08 08 09 09 10 2 2 11 11 11 SF-XX 13 13 14 PT-08 PT-08 PT-08 0'-0" AFF FINISH FLOOR 13'-6" AFF T.O. ADDITION PARAPET 21'-0" AFF T.O. EXISTING PARAPET 03 TYP 16 16 12 . 06 PT-08 PT-03 IPE-01 17 TYP 15 TYP 18 18 20 20 PT-07 12 12 12 PT-01 2 2 22 2 2 2 ..07 PT-07 PT-08 PT-03 PT-01 01 02 04 05 08 09 11 2 11 ?OH-B 12 13 PT-08 PT-08 0'-0" AFF FINISH FLOOR 13'-6" AFF T.O. ADDITION PARAPET 21'-0" AFF T.O. EXISTING PARAPET 03 12 06 06 IPE-01 17 TYP 15 TYP 18 20 12 PT-1 PT-1 2 2 C A7.01 PIES AND PINTS PT-07 PT-08 PT-03 PT-01 01 02 05 07 08 09 2 2 13 PT-08 PT-080'-0" AFF FINISH FLOOR 13'-6" AFF T.O. ADDITION PARAPET 21'-0" AFF T.O. EXISTING PARAPET 03 18 18 PIES & PINTS 20 2 © 2018 BY: CANVAS DESIGN, LLC ALL RIGHTS RESERVED PROJECT DATE: PROJECT #: THE ARRANGEMENTS DEPICTED HEREIN ARE THE SOLE PROPERTY OF CANVAS DESIGN LLC., AND MAY NOT BE REPRODUCED WITHOUT ITS WRITTEN PERMISSION NOTE: 1. ALL BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR W/ THE EXISTING CONDITIONS AND REQUIREMENTS OF THE PROJECT AND SHALL NOTIFY THE ARCHITECT OF ANY ERRORS AND OMISSIONS SUBSEQUENTLY DISCOVERED IN THE CONTRACT DOCUMENTS. 2. THE CONTRACT DOCUMENTS ARE COMPRISED OF THE DRAWINGS AND THE PROJECT MANUAL IN THEIR ENTIRETY. THE INFORMATION IN THESE DOCUMENTS IS DEPENDENT UPON AND COMPLEMENTARY OF EACH OTHER. SEPARATION OF THE CONTRACT DOCUMENTS SHALL NOT BE PERMITTED. IF THE CONTRACTOR CHOOSES TO SEPARATE THE DOCUMENTS, THEY DO SO AT THEIR OWN RISK AND EXPENSE. 3. ADDITIONALLY, SEE GENERAL INFORMATION ON “A0” SHEETS. 4. THE CLIENT ACKNOWLEDGES THE CONSULTANTS (ARCHITECT) DRAWINGS AND SPECIFICATION, INCLUDING ALL DOCUMENTS ON ELECTRONIC MEDIA AS INSTRUMENTS OF THE CONSULTANTS (ARCHITECT) PROFESSIONAL SERVICE. THE CLIENT SHALL NOT REUSE OR MAKE OR PERMIT TO BE MADE ANY MODIFICATION TO THE DRAWINGS AND SPECIFICATIONS WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF THE CONSULTANT (ARCHITECT). THE CLIENT AGREES TO WAIVE ANY CLAIM AGAINST THE CONSULTANT (ARCHITECT) ARISING FROM ANY UNAUTHORIZED TRANSFER, REUSE OR MODIFICATION OF THE DRAWINGS AND SPECIFICATIONS. 5. ARCHITECT CANNOT WARRANT THE ACCURACY OF DATA CONTAINED HEREIN. ANY USE OR REUSE OF ORIGINAL OR ALTERED CADD DESIGN MATERIALS BY THE USER OR OTHER PARITES WITHOUT THE REVIEW AND WRITTEN APPROVAL OF THE ARCHITECT SHALL BE AT THE SOLE RISK OF THE USER. FURTHERMORE, USER AGREES TO DEFEND, INDEMNIFY, AND HOLD ARCHITECT HARMLESS FROM ALL CLAIMS, INJURIES, DAMAGES, LOSSES, EXPENSES, AND ATTORNEY’S FEES ARISING OUT OF THE MODIFICATION OR REUSE OF THESE MATERIALS. 6. THESE DRAWINGS AS PART OF THE CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. THE DRAWINGS SHALL NOT BE SCALED. EXACT STATE AND LOCAL CODE REQUIREMENTS AND OTHER APPLICABLE CODE REQUIRMENTS SHALL BE VERIFIED BY AND ARE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR. ANY INFORMATION WHICH DIRECTLY CONFLICTS WITH ANY OF THESE CODES OR ANY DISCREPANCIES FOUND IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT. CANVAS DESIGN KYLE P. SCHNEIDER LICENSE # 11700160 EXPIRES: 12.31.2019 14550 CLAY TERRACE BLVD A29 CARMEL, INDIANA 46032 4/18/2018 9:15:06 PMC:\Users\schne\Desktop\CD\PROJECTS\17-0001 - PNP Clay Terrace\02-Model\17-001 PNP - Clay Terrace.rvt PIES AND PINTS CLAY TERRACE Permit Set 02-05-18 17-001 A5.01 EXTERIOR ELEVATIONS 1/4" = 1'-0"A EAST EXTERIOR ELEVATION 1/4" = 1'-0"B NORTH EXTERIOR ELEVATION 1/4" = 1'-0"C NORTHEAST EXTERIOR ELEVATION SEE SHEET A3.02 MATERIAL FINISH KEYSEE SHEET A3.02 MATERIAL FINISH KEY SEE SHEET A3.02 MATERIAL FINISH KEY # Description Date 2 REV 02 04/16/2018 2 2 2 05/14/18